HC101320QA563-0001.v0.pdf
PDF 10 KB Posted
- Solicitation number
- Not on record
- Issued by
-
Defense Information Systems Agency
View the file
Other files
| File | Type | Posted |
|---|---|---|
| HC101320QA563.v2 (1).pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
IQO INQUIRY
FM: PL8212
TO: Contractors
DATE (MM/DD/YYYY): 4/14/2020
SUBJECT: HC101320QA563-0001 Amend: 0001
A. TYPE ACTION: ADMIN AMEND
1. PURPOSE: THE PURPOSE OF AMEND 0001 IS AS FOLLOWS:
1. UPDATE PROPOSAL DUE DATE FROM 13 APR 20 TO 04 MAY 20.
ALL ELSE REMAINS UNCHANGED.
ORIGINAL SOLICITATION DATA:
SUBMIT A QUOTE TO:
1. PROVIDE, INSTALL, AND MAINTAIN AN INTERNET SERVICE WITH A MINIMUM OF 20
MEGABIT UP AND DOWNLOAD SPEEDS AT 1200 OHIO DRIVE; WASHINGTON DC 20024.
2. REQUEST MUST BE PHYSICALLY AND LOGICALLY DIVERSE FROM SOLICITATION
HC101320QA562. CONTRACTOR SHALL PROVIDE PROOF OF DIVERSITY TO INCLUDE
UPSTREAM PROVIDER. CIRCUIT MAY BE AWARDED TO SEPARATE CONTRACTORS TO
ACHIEVE FULL DIVERSITY.
3. REQUEST 4 PUBLIC STATIC IP ADDRESSES INDEPENDENT FROM SOLICITATION
HC101320QA562. NO BGP REQUIREMENT.
4. TSP IS ALSO BEING RENEWED FOR THIS CIRCUIT.
***REMARKS***
1. CONTRACTOR MUST CONTACT THE LISTED POC AT LEAST 72 HRS PRIOR TO
INSTALLATION. POC INFORMATION WILL BE PROVIDED AT TIME OF AWARD.
2. THIS REQUIREMENT MUST BE ENGINEERED AND PROVISIONED TOTALLY DIVERSE END
TO END TO THE GOVERNMENT'S SERVICE DELIVERY POINTS (SDP'S) FROM SOLICITATION
HC101320QA562; MEANING THAT THE PHYSICAL PATHS ARE TOTALLY SEPARATE
INCLUDING MAN HOLES, CONDUIT, CENTRAL OFFICE LOCATIONS, AND FIBER BUILDS.
ADDITIONALLY, NO COMMON ENTRY POINTS AND MAINTAIN A MINIMUM OF 10 METERS
PHYSICAL SEPARATION FROM SOLICITATION HC101320QA562.
3. CONTRACTOR MUST PROVIDE DISA COLOR POWERPOINT DRAWINGS FOR TECHNICAL
REVIEW SHOWING THE ROUTES FROM THE COMMERCIAL DEMARKS TO THE SUPPORTING
CENTRAL OFFICES AND OR WIRING CENTERS ENSURING THE PHYSICAL END TO END
DIVERSITY REQUIREMENTS ARE BEING MET. DRAWINGS ALSO TO INCLUDE SEPARATION
DISTANCE AND TOTAL FIBER MILES. ADDITIONALLY MUST PROVIDE COLOR CODED MAPS
HC101320QA563-0001
AND MUST BE RED LINED SHOWING HOW THE CIRCUIT WILL BE ROUTED END TO END
FROM THE CUSTOMER LOCATION TO THE CONTRACTOR'S SERVICE CENTER.
4. SERVICE AVAILABILITY 99.5% OR BETTER, WITH 30 MINUTE RESPONSE; 2 HOUR
RESTORAL; UPDATES PROVIDED EVERY 60 MINUTES UNTIL CIRCUIT IS FULLY TESTED AND
OPERATIONAL.
5. CONTRACTOR MUST HAVE 24 HOUR MONITORING FACILITIES AND EQUIPMENT TO
TROUBLESHOOT PATH AND ASSOCIATED EQUIPMENT AFTER INSTALLATION.
A. COMPLETE OUTAGE: INTERFACE OR PROTOCOL NON-OPERATIONAL RESPONSE
TIME FROM INITIAL REPORT OR DETECTION OF CIRCUIT DOWN WILL BE 30 MINUTES AND
THE MEAN RESTORE TIME TO REPAIR (MTTR) MUST BE TIME TO REPAIR (MTTR) MUST BE
120 MINUTES.
B. IMPAIRMENT: IMPAIRED THROUGHPUT OR IMPAIRED CIRCUIT OPERATION (EG.
LATENCY ISSUES, INTERMITTENTLY FLAPPING/BOUNCING, INTERMITTENT ISSUES)
RESPONSE TIME FROM INITIAL REPORT OR DETECTION OF CIRCUIT IMPAIRMENT WILL BE
30 MINUTES AND THE MEAN RESTORE TIME TO REPAIR (MTTR) MUST BE 240 MINUTES.
6. JURISDICTIONAL CLASS: INTERSTATE USE, 100 PERCENT
7. CIRCUIT MUST AVOID SATELLITE LINKS.
8. CONTRACTOR MUST CALL DISA NOSC AT LEAST 72 HRS PRIOR TO MAINTENANCE.
9. CUSTOMER WILL ACCEPT EARLIEST POSSIBLE INSTALL DATE. INSTALL SOONER IF
POSSIBLE (SIP).
10. THIS IS A CANDIDATE FOR RESTORAL TELECOMMUNICATIONS SERVICE PRIORITY
(TSP).
11. TECHNICAL ACCEPTABILITY EVALUATION CRITERIA: A QUOTE MUST COMPLY WITH
ALL STANDARD PROVISIONS, PROVISIONS, CLAUSES, AND ADDRESS SECTIONS F-M OF
THE SOLICITATION TO BE DEEMED TECHNICALLY ACCEPTABLE. ALL PORTIONS OF THE
SOLICITATION SHOULD BE CAREFULLY REVIEWED FOR ALL MANDATED REQUIREMENTS
OUTLINED WITHIN THE STANDARD PROVISIONS AND DOCUMENTATION REQUESTED AS
FOUND IN SECTION M AND AFFILIATED ATTACHMENTS. QUOTATIONS MUST INCLUDE
ALL REQUIRED DOCUMENTS AND RESPONSES INDICATED FROM THESE STANDARD
PROVISIONS, PROVISIONS, CLAUSES, SECTION M, AND AFFILIATED ATTACHMENTS
TO BE CONSIDERED TECHNICALLY ACCEPTABLE AND/OR ELIGIBLE FOR AWARD. IN
RESPONSE TO THIS IQO SOLICITATION, NO TERMS, CONDITIONS, OR ASSUMPTIONS WILL
BE ENTERTAINED. IF TERMS, CONDITIONS, AND/OR ASSUMPTIONS ARE INCLUDED IN
A QUOTATION, THE QUOTATION MAY BE EXCLUDED ON GROUNDS THAT IT FAILED TO
COMPLY WITH THE IQO SOLICITATION INSTRUCTIONS.
12. EVALUATION CRITERIA: IN ADDITION TO THE PROCEDURES OUTLINED IN STANDARD
PROVISION 23, TECHNICAL EVALUATION TEAM MEMBERS WILL INCLUDE GOVERNMENT
PERSONNEL AND MAY INCLUDE GOVERNMENT'S CONTRACTED ADVISERS. GOVERNMENT
PERSONNEL WILL MAKE THE FINAL DETERMINATION OF TECHNICAL ACCEPTABILITY.
13. IF THERE ARE QUESTIONS REGARDING SITE SURVEYS OR SITE INFORMATION, PLEASE
CONTACT THE CONTRACT SPECIALIST LISTED ON THIS SOLICITATION PRIOR TO THE
QUOTE DUE DATE.
M. ADDITIONAL INFORMATION:
3. TSR NUMBER: DO28FEB200172
4. CCSD: WIPDZA21
Z. DITCO CONTACT:
Emily Stanowski
618-418-6665 emily.a.stanowski.civ@mail.mil
Amanda M. Romanitis
DITCO Contracting Officer
Unless otherwise specified, all other terms and conditions are unchanged.
Paragraph M.3.TSR NUMBER change from:
DO28FEB200172A
To:
DO28FEB200172
Paragraph V.QUOTE DUE DATE AND TIME change from:
Jul 27, 2020 12:00:00 PM CDT
To:
May 4, 2020 12:00:00 PM CDT
File details come from the government source that posted it. Updated .