HC101319QB319-0001.v1-1.pdf
PDF 16 KB Posted
- Solicitation number
- HC101319QB319
- Issued by
-
Defense Information Systems Agency
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
IQO INQUIRY
FM: PL8211
TO: Contractors
DATE (MM/DD/YYYY): 12/6/2019
SUBJECT: HC101319QB319-0001 Amend: 0001
A. TYPE ACTION: ADMIN AMEND
1. PURPOSE: AMENDMENT 0001 IS ISSUED TO REVISE PURPOSE STATEMENT
AND UPDATE PARAGRAPHS 5, 6 AND 7. CONTRACTORS ARE DIRECTED TO REVIEW
SUBMISSIONS AND RESUBMIT (IF NEEDED) NLT NOON CST ON 10 DEC 19.
ALL ELSE REMAINS UNCHANGED.
***THIS IS A REAWARD ACTION***
1. SUBMIT A QUOTE TO PROVIDE, INSTALL, AND MAINTAIN A (OC-12) 622.08MB, PT-
TO-PT, ON THE BETWEEN: (BLDG)322 (FL)1ST, (RM)FRAME ROOM, 322 PRATT AVE,
CARLISLE BARRACKS, PS 17013/CCI AND (BLDG)308, (FL)1ST, (RM)203, 5450 CARLISLE PIKE, MECHANICSBURG, PA 17050/CCI
CONTRACTORS SHALL MEET RTD OF 10 MILLISECONDS TO SUPPORT THE GOVERNMENT
MISSION. IF THE RTD CHANGES IT WOULD BE NOTIFIED VIA AMENDMENT TO SOLICITATION.
GOVERNMENT REQUIRED CHANNELIZATION: 9 STS-1'S (TIMESLOTS 1-9); 1 STS-3C
(TIMESLOTS 10-12)
2. CONTRACTORS ARE RESPONSIBLE FOR READING AND ADDRESSING ALL TECHNICAL
REQUIREMENTS OF THIS INQUIRY/SOLICITATION, READING AND AGREEING WITH THE
STANDARD PROVISIONS, PROVIDE PRICE QUOTATION IN ACCORDANCE WITH STANDARD
PROVISION 4, AND MEET THE REQUESTED SERVICE DATE.
3. THE SERVICE DATE TO BE MET IS: 13 APR 20 (SIP) TO COMPLY WITH PROCUREMENT
ACQUISITION LEAD TIME (PALT) FOR THIS TYPE OF SERVICE. ANY CHANGES TO THE
ORIGINAL SERVICE DATE WILL BE NOTIFIED VIA AMENDMENT TO THE SOLICITATION AND
POSTED TO FBO. THE GOVERNMENT ASSUMES THAT CONTRACTORS HAVE CONSIDERED
ALL ISSUES THAT MAY DELAY THE DELIVERY OF CIRCUIT ON REQUESTED SERVICE
DATE. THE GOVERNMENT MAY CANCEL, TERMINATE, OR REQUEST CONSIDERATION IAW
STANDARD PROVISION 42 FOR FAILURE TO MEET CONTRACTUAL SERVICE.
4. CONTRACTORS MUST ENSURE THAT QUOTES SHALL INCLUDE SUFFICIENT DETAIL
FOR EFFECTIVE EVALUATION AND SHOULD NOT SIMPLY REPHRASE OR RESTATE THE
GOVERNMENT REQUIREMENTS. RATHER, CONTRACTORS MUST PROVIDE CONVINCING
RATIONALE TO ADDRESS HOW THEY INTEND TO MEET THE REQUIREMENT. IN RESPONSE
TO THIS SOLICITATION, NO TERMS OR CONDITIONS PLACED UPON THE GOVERNMENT,
NOR ASSUMPTIONS WILL BE ACCEPTED. CONTRACTORS ARE INSTRUCTED TO SUBMIT
HC101319QB319-0001
QUESTIONS AND REQUEST CLARIFICATIONS OF THE REQUIREMENT (S) BEFORE
SUBMITTING QUOTES. QUOTES MUST BE UPLOADED TO IDEAS.
5. THIS REQUIREMENT MUST BE WORKED IN CONJUNCTION WITH SOLICITATION
HC101319QB153/TSR SG23JUL196255.
6. NOT APPLICABLE
7. CONTRACTOR MUST PROVIDE DITCO COLOR POWERPOINT DRAWINGS FOR TECHNICAL
REVIEW SHOWING THE ROUTES FROM THE COMMERCIAL DEMARCS TO THE SUPPORTING
CENTRAL OFFICES AND OR WIRING CENTERS. DRAWINGS ALSO TO INCLUDE TOTAL FIBER
MILES AND ROUND TRIP DELAY (RTD). ADDITIONALLY MUST PROVIDE COLOR CODED
MAPS
AND MUST BE RED LINED SHOWING HOW THE CIRCUIT WILL BE ROUTED END TO END
FROM THE CUSTOMER A LOCATION TO THE CUSTOMER Z LOCATION.
8. PRE AWARD SITE SURVEYS ARE AUTHORIZED (AT CONTRACTOR EXPENSE) AND
SHOULD BE CONDUCTED IN COORDINATION WITH LOCAL POCS AT EACH GOVERNMENT
SITE. IT IS HIGHLY RECOMMENDED THAT AT A MINIMUM, CONTRACTORS CONDUCT PHONE
SURVEYS TO ADEQUATELY ASSESS THE MAGNITUDE OF THE WORK TO BE PERFORMED IN
DETERMINING THEIR PRICE STRATEGY.
9. CONTRACTORS MUST ADDRESS IN QUOTES COMPLIANCE WITH TESTING AND
ACCEPTANCE REQUIREMENTS.
10. TESTING & ACCEPTANCE REQUIREMENTS MUST BE COORDINATED WITH CUSTOMER
ACCEPTANCE AUTHORITY BEFORE NOTICE OF COMPLETION IS SUBMITTED TO DITCO.
FOR DISA REQUIREMENTS THE TESTING AND ACCEPTING AUTHORITY IS:
THE DISA ACTIVATIONS TEAM.
11. ESTABLISH TSP: TSP0EKXR1-01
15. THIS IS A REAWARD OF A CURRENT SERVICE, (CTLL000070EBM). IF THE INCUMBENT
QUOTE IS EVALUATED AS THE LOWEST PRICE TECHNICABLE ACCEPTABLE, THE CURRENT
CSA WILL BE ADMINSTRATIVELY DISCONTINUED USING THE DATE PRIOR TO THE START
DATE OF NEW CSA.
FAILURE TO READ AND ADDRESS ANY OF THE TECHNICAL REQUIREMENTS AND SERVICE
DATE REQUESTED IN THIS INQUIRY SHALL RENDER THE QUOTE NON-COMPLIANT AND
RESULT IN IT BEING EXCLUDED FROM EVALUATION AND AWARD.
1. CIRCUIT REQUIRES THE FOLLOWING PARAMETERS:
FIBER TERMINATION: FRAME FORMAT: STS-12, 1310NM. RATE: PLUS OR MINUS 20 PPM
GOVERNMENT PROPOSED CHANNELIZATION: 9 STS-1'S (TIMESLOTS 1-9) 1 STS-3C
(TIMESLOTS 10-12).
LINE MUST REMAIN FULLY OPERATIONAL AND AVAILABLE TOUSERS 24 HOURS A DAY,
SEVEN DAYS PER WEEK, AT LEAST 99.5% OR BETTER.
REQUEST ONE-HOUR RESPONSE TIME TURN-AROUND TO REPAIR ONCE TROUBLE-CALL
HAS BEEN REPORTED.
GFE CLOCKING: VENDOR ESFU (OR EQUIVALENT) NOT TO BE ENGINEERED INTO CIRCUIT.
SINGLE MODE FIBER TERMINATIONS SC/SC CONNECTORS.
NO NETWORK INTERFACE UNIT.
DEDICATED PATH.
VENDOR REQUIRED TO HAVE CIRCUIT VISIBILITY TO ASSIST IN ANY CIRCUIT OUTAGES.
VENDOR MUST CONDUCT A SATISFACTORY 72 HOUR END TO END TEST UTILIZING A 2E23
TEST PATTERN IAW ANSI STANDARD T1.514. ADDITIONALLY, VENDOR MUST CONDUCT
SATISFACTORY CONTINUITY CHECKS AND INITIAL 15 MINUTE END TO END TEST ON EACH
STS-1 AND STS-3C. AFTER COMPLETION OF CONTINUITY CHECKS AND INITIAL TESTING,
VENDOR MUST COMPLETE A SATISFACTORY 72 HOUR END TO END TEST ON THE FIRST
STS-1 (TIME-SLOT NUMBER 1) END TO END PRIOR TO TURNING OVER THE OC-12 TO
THE ACCEPTING AUTHORITY. THE VENDOR TEST SET/SETS MUST HAVE THE ABILITY TO
PRINT THE TEST RESULTS AND THOSE RESULTS MUST BE E-MAILED TO THE ACCEPTING
AUTHORITY FOR REVIEW.
VENDOR MUST HAVE A 24X7 NETWORK OPERATIONS CENTER.
THE COMMERCIAL CIRCUIT WILL BE ACCEPTED ON BEHALF OF THE GOVERNMENT BY THE
GOC GNOSC:
PRI POC: DISA GLOBAL CASA INFRASTRUCTURE INTEGRATION LEASE BB TEAM
PHONE: (C) 618-418-9813, (D) 418-9813
EMAIL: DISA.SCOTT.GLOBAL.MBX.CASA-INFRASTRUCTURE-INTEGRATION-LEASE-BB-
T@MAIL.MIL
ALT POC: ORGANIZATIONAL NUMBER (CASA RF CIRCUIT ACTIVATIONS)
PHONE: (C) 618-418-8691, (D) 418-8691
EMAIL: DISA.SCOTT.GLOBAL.MBX.RF-CIRCUIT-ACTIVATIONS@MAIL.MIL
(C) 618-220-8843 (D) 770-8843.
THE VENDOR MUST PROVIDE:
1) THE LONG HAUL CIRCUIT NUMBER.
2) THE 1-800 TROUBLE REPORT NUMBER.
3) THE LOCAL CIRCUIT IDENTIFIER FOR EACH LOCATION TO THE ACCEPTING AUTHORITY
PRIOR TO THE GOVERNMENT ACCEPTING SERVICE. INSIDE WIRING MUST BE COMPLETED
AND TESTED PROPERLY PRIOR TO TURN-UP TO THE GOVERNMENT.
2. VENDOR WINNING AWARD IS RESPONSIBLE FOR INSTALLATION AND MAINTENANCE OF
OC-12 SERVICE IAW THE UNIQUE INSTALLATION FACTORS.
3. INSIDE WIRING IS AUTHORIZED IAW WITH THE UNIQUE INSTALLATION FACTORS.
4. VENDOR MUST COORDINATE SITE VISIT WITH POC'S 72 HOURS IN ADVANCE PRIOR TO
REQUIRING ACCESS TO FACILITIES AT BOTH USER LOCATIONS.
M. ADDITIONAL INFORMATION:
3. TSR NUMBER: SG23JUL196254
4. CCSD: 6VY1
Z. DITCO CONTACT:
Jennifer Voss
618-418-6641 jennifer.n.voss.civ@mail.mil
Angelina Hutson
DITCO Contracting Officer
Unless otherwise specified, all other terms and conditions are unchanged.
Paragraph V.QUOTE DUE DATE AND TIME change from:
Dec 6, 2019 12:30:00 PM CST
To:
Dec 10, 2019 12:30:00 PM CST
File details come from the government source that posted it. Updated .