HC101319QB235__TESTING_REQUIREMENTS.docx
DOCX document 14 KB Posted
- Solicitation number
- HC101319QB235
- Issued by
-
Defense Information Systems Agency
About this file
This solicitation requests quotes to provide, install, and maintain a 2.5 gigabit per second wavelength service between Malmstrom Air Force Base in Montana and Joint Base Lewis-McChord in Washington. Quotes are due by October 25, 2019 and must include monthly recurring charges and non-recurring charges by line item. The selected vendor must comply with commercial item terms and conditions and submit representations and certifications. The service must meet technical requirements for availability, error rates, jitter, delay, and other performance metrics as outlined in the attached testing and acceptance criteria document. The Defense Information Systems Agency is the contracting agency.
Not Listed
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Vendor_Sample_Maps_Version2.pdf | ||
| Vendor_Block_Sample_Version3.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A. NOTE 1 (JITTER).: IN A STEADY-STATE CONDITION, THE PATTERN OF SYNCHRONOUS TRANSPORT SIGNAL (STS) POINTER ADJUSTMENTS, SDN TO SDN (END-TO-END THROUGH THE SERVICE PROVIDED NETWORK OUTPUTS), SHALL BE NO MORE STRESSFUL (I.E., CREATE MORE JITTER THROUGH THE DESYNCHRONIZER AS DESCRIBED IN TABLE 6 OF ANSIT1.105.03-1994) THAN THE POINTER ADJUSTMENT SEQUENCE IN FIGURE 5 OF ANSI T1.105.03-1994. DURING TRANSIENT EVENTS (WHICH SHALL OCCUR NO MORE THAN 2 TIMES PER DAY), THE PATTERN OF STS POINTER ADJUSTMENTS, SDN TO SDN (END-TO-END THROUGH THE SERVICE PROVIDED NETWORK OUTPUTS), SHALL BE FOUR OR LESS PER HOUR. ADDITIONALLY, THE MAXIMUM TIME INTERVAL ERROR (MTIE) OVER A PERIOD OF SECONDS, OR WANDER, SHALL NOT EXCEED (.01S + 10000) NANOSECONDS FOR VALUES OF S GREATER THAN 10,000.
B. WAVELENGTH TRANSMISSION SERVICES: WAVELENGTH TRANSMISSION SERVICES FOR RATES OF 2.5GBPS SHALL BE IN ACCORDANCE WITH ITU-T RECOMMENDATIONS G.709(03/2003), G.707(12/03), G.957(03/06), G.692(10/98) & TELCORDIA GR253-IE4. THE PROVIDED WAVELENGTH TRANSMISSION SERVICE SHALL NOT INHIBIT GOVERNMENT OPERATION OF UNDERLYING PROTOCOLS AND TRANSPORT SYSTEMS SUCH AS, BUT NOT LIMITED TO, SONET/SDH, IP, ATM, GIGABIT ETHERNET, AND ENCRYPTION. THE WAVELENGTH TRANSMISSION SERVICE PROVIDED SHALL PASS ALL PAYLOAD, PATH AND LINE OVERHEAD BYTES TRANSPARENTLY (UNTOUCHED/UNALTERED) AND WITHOUT MONITORING SDP TO SDP. THERE SHALL NOT BE ANY LINE TERMINATING EQUIPMENT (LTE) BETWEEN SDP AND SDP.
C. 2.5GB WAVE SERVICE MUST BE TERMINATED TO THE LINE SIDE OF THE FIBER TERMINATING PATCH PANEL INSTALLED IN THE DISA IE1 PROVIDED MSPP SUITE AT MALMSTROM AFB, MT., AND THE FIBER TERMINATING PATCH PANEL INSTALLED IN THE DISA IE1 PROVIDED ODXC SUITE AT FORT LEWIS, WA.
D. TELECOMM PROVIDER MUST CONTACT DISA CONUS TIER-II MSPP ENGINEERING UPON RECEIPT OF A VALID TSO TO ESTABLISH THE COORDINATION AND ACTIVATION PROCESS. PRI POC: CONTACT: MIKE REEVES (C) 618-418-8973 (D) 418-8973 ALT POC: CONTACT: DON NORDENHOLT (C) 618-418-8643 (D) 418-8643 ALT POC: CONTACT: AARON SMITH (C) 618-418-9820 (D) 418-9820 ALT POC: CONTACT: BOB RISKY (C) 618-418-8632 (D) 418-8632 ALT POC: ORGANIZATIONAL NUMBER (C) 618-418-8691 (D) 418-8691. ONCE TELECOMM PROVIDER HAS COMPLETED INSIDE WIRING FROM THE DWDM EQUIPMENT SUITE TO THE GOVERNMENT SERVICE DELIVERY POINT (SDP) AT EACH LOCATION, THEY MUST ENSURE THE LIGHT LEVEL READINGS (DB LOSS) ARE ADJUSTED TO READ -5 TO -13 LOSS. ADDITIONALLY, THESE LEVELS MUST BE DOCUMENTED ON THE NOTICE OF COMPLETION (NOC) SENT TO DITCO. THE 2.5GB WAVE SERVICE MUST PASS A DOCUMENTED SATISFACTORY 72 HOUR END TO END TEST IAW ITU STANDARD M.2101 PRIOR TO TURN UP TO THE GOVERNMENT.
(A) FIBER TERMINATION: SINGLE-MODE INTERFACE REQUIREMENT/INTERFACE DATA RATE: LINE CODING, FRAME FORMAT, PHYSICAL CONNECTOR, 2.5 GBPS, NRZ, SCRAMBLED PER ANSI T1.104-1991 (R2003). ALL OPTIONS DEFINED SC CONNECTOR, SINGLE-MODE FIBER PER ANSI T1.105.06-2002 (SR-0, SR-1, IR-1, IR-2, LR-1, LR-2, LR-3).
(B) LINE MUST REMAIN FULLY OPERATIONAL AND AVAILABLE TO USERS 24 HOURS A DAY, SEVEN DAYS PER WEEK, AT LEAST 99.5% OR BETTER.
(C) ONE-HOUR RESPONSE TIME TURN-AROUND MUST OCCUR TO REPAIR ONCE TROUBLE-CALL HAS BEEN REPORTED.
(D) GFE CLOCKING: VENDOR ESFU (OR EQUIVALENT) NOT TO BE ENGINEERED INTO CIRCUIT.
(E) SINGLE MODE FIBER TERMINATIONS "SC" CONNECTORS
(F) NO NETWORK INTERFACE UNIT.
(G) DEDICATED PATH.
(H) CARRIER REQUIRED TO HAVE CIRCUIT VISIBILITY TO ASSIST IN ANY CIRCUIT OUTAGES.
(I) THE VENDOR MUST CONDUCT A 72 HOUR SATISFACTORY END TO END TEST ON THE 2.5 WAVE SERVICE IAW ITU STANDARD M.2101. ADDITIONALLY, THE VENDOR TEST SET/SETS MUST HAVE THE ABILITY TO PRINT THE TEST RESULTS AND THOSE RESULTS MUST BE EMAILED TO THE ACCEPTING AUTHORITY FOR REVIEW.
(J) VENDOR MUST HAVE A 24X7 NETWORK OPERATIONAL CENTER OF THIS 2.5GB WAVE SERVICE.
(K) THE VENDOR MUST PROVIDE: 1) THE LONG HAUL CIRCUIT NUMBER AND THE 1-800 TROUBLE REPORT NUMBER TO THE ACCEPTING AUTHORITY PRIOR TO THE GOVERNMENT ACCEPTING SERVICE. INSIDE WIRING MUST BE COMPLETED AND TESTED PROPERLY IAW THE ORDER PRIOR TO TURNUP TO THE GOVERNMENT. VENDOR IS RESPONSIBLE FOR INSTALLATION AND MAINTENANCE OF 2.5GB WAVE SERVICE IAW UNIQUE INSTALLATION FACTORS. INSIDE WIRING IS AUTHORIZED IAW WITH THE UNIQUE INSTALLATION FACTORS. VENDOR MUST COORDINATE SITE VISIT WITH POC'S 72 HOURS IN ADVANCE PRIOR TO REQUIRING ACCESS TO FACILITIES AT BOTH USER LOCATIONS. FOR UNSATISFACTORY SERVICE OR TO REPORT EQUIPMENT AND/OR CIRCUIT PROBLEMS INVOLVING DISA PROVIDED TRANSPORT AND/OR EQUIPMENT, PLEASE CONTACT THE DISN CUSTOMER CONTACT CENTER (DCCC) SCOTT AFB, IL. TOLL FREE: 1-855-868-9500 COML: 618-418-9500 DSN: 312-418-9500. DD FORM 1368 WILL BE SUBMITTED ON THIS TRUNK IAW DISAC-DITCO 350-135-1 BY RNSOC, SCOTT AFB, IL.
SPECIFIC FORMAT TO BE USED IS:
LINE RATE: 2.5GB.
LINE CODE: NRZ
FRAME FORMAT: SCRAMBLED IAW ANSI T1.104-1991 (R2003)
1. TEST AND ACCEPTANCE: FIBER OPTIC 2.5GB WAVE CIRCUITS SHALL PASS A FULLY DOCUMENTED SATISFACTORY SOAK TEST BY THE CONUS GNOSC AT SCOTT AFB, IL. PRIMARY: (C) 618-418-8691 (D) 418-8691
2. THE WAVELENGTH TRANSMISSION SERVICE PROVIDED SHALL MEET THE FOLLOWING PERFORMANCE REQUIREMENTS ON A MONTHLY BASIS. PERFORMANCE REQUIREMENT/PERFORMANCE SPECIFICATION: NON-DIVERSE/NON-PROTECTED AVAILABILITY: GREATER THAN OR EQUAL TO 99.5% OR BETTER. MONTHLY SHORT INTERRUPTION EVENT COUNT (SEIC): LESS THAN OR EQUAL TO 9% ERRORED SECONDS (ES): LESS THAN OR EQUAL TO 0.005% SEVERELY ERRORED SECONDS (SES): LESS THAN OR EQUAL TO 0.00035 BACKGROUND BLOCK ERROR RATIO (BBER): LESS THAN OR EQUAL TO 5 X 10-6 BIT COUNT INTEGRITY (BCI)/PATTERN SLIP (PAT SLIP): LESS THAN OR EQUAL TO 1 PER 72 HOURS JITTER SEE NOTE 1 (JITTER) BER: LESS THAN OR EQUAL TO 1X10-12 DELAY (ONE WAY): * LESSER OF 10 MSEC OR (0.01 X D MSEC) * WHERE "D" IS THE SDP TO SDP TRANSMISSION DISTANCE, MEASURED SHORTEST GREAT CIRCLE, IN KILOMETERS.
3. ROUND TRIP DELAY (RTD): RTD SHALL BE MEASURED OVER THE 2.5GB WAVE CIRCUIT AND SHALL BE LESS THAN OR EQUAL TO 22 MILLISECONDS TO EFFECTIVELY SUPPORT THE GOVERNMENT'S MISSION. THE GOVERNMENT RESERVES THE RIGHT TO ACCEPT A HIGHER RTD ONLY IF SUPPORTED BY ACTUAL PHYSICAL FIBER DISTANCE BETWEEN THE TWO END LOCATIONS. ADDITIONALLY THE GOVERNMENT RESERVES THE RIGHT TO REJECT A PROPOSED PATH IF DEEMED EXCESSIVELY LONG WITHOUT WRITTEN JUSTIFICATION IN THE PROPOSAL. JUSTIFICATION FOR EXCESSIVE FIBER MILEAGE COULD BE DIVERSITY/AVOIDANCE REQUIREMENTS, LIMITED INFRASTRUCTURE, AVAILABLE PROVIDERS, GEOGRAPHIC AND PHYSICAL LIMITATION. THE GOVERNMENT ACCEPTING AUTHORITY WILL CONFIRM THE RTD DURING THE TURN-UP AND TEST PHASE AND IF IT DOES NOT ALIGN WITH THE CONTRACTORS PROPOSAL DISA IE161 WILL NOTIFY DITCO IMMEDIATELY IN WRITING.