HC101319QB175-0001.v0.pdf
PDF 13 KB Posted
- Solicitation number
- HC101319QB175
- Issued by
-
Defense Information Systems Agency
View the file
Other files
| File | Type | Posted |
|---|---|---|
| HC101319QB175.v0.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
IQO INQUIRY
FM: PL8211
TO: Contractors
DATE (MM/DD/YYYY): 8/6/2020
SUBJECT: HC101319QB175-0001 Amend: 0001
A. TYPE ACTION: ADMIN AMEND
1. PURPOSE: THE PURPOSE OF AMEND 0001 IS TO SPECIFY VENDORS AT FORT GORDON
WILL COMPLETE EXTENSION OF ANY CIRCUITS/TRUNKS IN BLDG 34500 AND ANY ROOM
WITHIN THE FACILITY. INSIDE WIRING IS REQUIRED. SEE UNIQUE INSTALL FACTORS.
CIRCUIT PARAMETERS HAVE BEEN INCLUDED IN THE PURPOSE STATEMENT.
VENDORS ARE REQUESTED TO UPDATE THEIR QUOTES. THE QUOTE DUE DATE HAS BEEN
UPDATED TO 24 AUG 2020.
THE SERVICE DATE HAS BEEN UPDATED TO 22 DEC 2020.
ALL ELSE REMAINS THE SAME.
SUBMIT A QUOTE TO PROVIDE, INSTALL, AND MAINTAIN A CHANNELIZED OC-12 (622.08MB)
BETWEEN BLDG 9, NETWORK ROOM, 85 HASE ROAD, FORT STEWART, GA., AND BLDG
34500, ROOM 120, 245 "O" CLUB DRIVE, FORT GORDON, GA.
- THIS REQUIREMENTS HAS THE BELOW MANDATORY TECHNICAL REQUIREMENTS:
GOVERNMENT REQUIRED CHANNELIZATION:
9 STS-1'S (TIMESLOTS 1-9)
1 STS-3C (TIMESLOTS 10-12)
- CONTRACTORS MUST COMPLY WITH TESTING & ACCEPTANCE REQUIREMENTS.
2. CONTRACTORS ARE RESPONSIBLE FOR READING AND ADDRESSING ALL TECHNICAL
REQUIREMENTS OF THIS SOLICITATION, READING AND AGREEING WITH THE STANDARD
PROVISIONS, PROVIDE PRICE QUOTATION IN ACCORDANCE WITH STANDARD PROVISION 4,
AND MEET THE REQUESTED SERVICE DATE.
3. THE SERVICE DATE TO BE MET IS: 03 NOV 20 (SIP) TO COMPLY WITH PROCUREMENT
ACQUISITION LEAD TIME (PALT) FOR THIS TIPE OF SERVICE. THE GOVERNMENT ASSUMES
THAT CONTRACTORS HAVE CONSIDERED ALL ISSUES THAT MAY DELAY THE DELIVERY
OF SERVICE ON REQUESTED SERVICE DATE AND MAY CANCEL, TERMINATE, OR REQUEST
CONSIDERATION IAW STANDARD PROVISION 42 FOR FAILURE TO MEET CONTRACTUAL
SERVICE DATE OR COMPLY WITH ANY CONTRACT TERMS OR CONDITIONS.
HC101319QB175-0001
4. CONTRACTORS MUST ENSURE THAT QUOTES SHALL INCLUDE SUFFICIENT DETAIL
FOR EFFECTIVE EVALUATION AND SHOULD NOT SIMPLY REPHRASE OR RESTATE THE
GOVERNMENT REQUIREMENTS. RATHER, CONTRACTORS MUST PROVIDE CONVINCING
RATIONALE TO ADDRESS HOW THEY INTEND TO MEET THE REQUIREMENT.
5. QUOTES MUST BE UPLOADED TO IDEAS. GOVERNMENT IS NOT RESPONSIBLE FOR
MISSING OR OVERLOOKED QUOTES.
6. TELECOM PROVIDER MUST PROVIDE DITCO COLOR POWERPOINT DRAWINGS FOR
TECHNICAL REVIEW SHOWING THE ROUTES FROM THE COMMERCIAL DEMARCS TO THE
SUPPORTING CENTRAL OFFICES AND OR WIRING CENTERS. DRAWINGS ALSO TO INCLUDE
TOTAL FIBER MILES AND ROUND TRIP DELAY (RTD). ADDITIONALLY MUST PROVIDE COLOR
CODED MAPS AND MUST BE RED LINED SHOWING HOW THE CIRCUIT WILL BE ROUTED END
TO END FROM THE CUSTOMER A LOCATION TO THE CUSTOMER Z LOCATION.
7. THIS IS A REAWARD/REPLACEMENT OF A CURRENT SERVICE, ASTI000016EBM. IF THE
INCUMBENT QUOTE IS EVALUATED AS THE LOWEST PRICE TECHNICABLE ACCEPTABLE,
THE CURRENT CSA WILL BE ADMINSTRATIVELY DISCONTINUED WITHIN 30 DAYS OF
INCUMBENT CONTRACTOR RECEIVING AWARD. THE DISCONTINUE DATE OF OLD CSA WILL
BE THE DAY PRIOR TO THE START DATE OF NEW CSA.
CIRCUIT PARAMETERS
A) FIBER TERMINATION: FRAME FORMAT: STS-12, 1310NM RATE: PLUS OR MINUS 20 PPM
(B) GOVERNMENT PROPOSED CHANNELIZATION: 9 STS-1'S (TIMESLOTS 1-9) 1 STS-3C
(TIMESLOTS 10-12)
(C) LINE MUST REMAIN FULLY OPERATIONAL AND AVAILABLE TO USERS 24 HRS A DAY,
SEVEN DAYS PER WEEK, AT LEAST 99.5% OR BETTER.
(D) REQUEST ONE-HR RESPONSE TIME TURN-AROUND TO REPAIR ONCE TROUBLE-CALL
HAS BEEN REPORTED.
(E) GFE CLOCKING: VENDOR ESFU (OR EQUIVALENT) NOT TO BE ENGINEERED INTO
CIRCUIT.
(F) SINGLE MODE FIBER TERMINATIONS SC/SC CONNECTORS
(G) NO NETWORK INTERFACE UNIT.
(H) DEDICATED PATH.
(I) VENDOR REQUIRED TO HAVE CIRCUIT VISIBILITY TO ASSIST IN ANY CIRCUIT OUTAGES.
(J) VENDOR MUST CONDUCT A SATISFACTORY 72 HR END TO END TEST UTILIZING A 2E23
TEST PATTERN IAW ANSI STANDARD T1.514. ADDITIONALLY, VENDOR MUST CONDUCT
SATISFACTORY CONUTITY CHECKS AND INITIAL 15 MINUTE END TO END TEST ON EACH
STS-1 AND STS-3C. AFTER COMPLETION OF CONUTITY CHECKS AND INITIAL TESTING,
VENDOR MUST COMPLETE A SATISFACTORY 72 HR END TO END TEST ON THE FIRST
STS-1 (TIME-SLOT NUMBER 1) END TO END PRIOR TO TURNING OVER THE OC-12 TO
THE ACCEPTING AUTHORITY. THE VENDOR TEST SET/SETS MUST HAVE THE ABILITY TO
PRINT THE TEST RESULTS AND THOSE RESULTS MUST BE E-MAILED TO THE ACCEPTING
AUTHORITY FOR REVIEW.
(K) VENDOR MUST HAVE A 24X7 NETWORK OPERATIONS CENTER.
(L) THE VENDOR MUST PROVIDE: 1) THE LONG HAUL CIRCUIT NUMBER; 2) THE 1-800
TROUBLE REPORT NUMBER; AND 3) THE LOCAL CIRCUIT IDENTIFIER FOR EACH LOCATION
TO THE ACCEPTING AUTHORITY PRIOR TO THE GOVERNMENT ACCEPTING SERVICE.
INSIDE WIRING MUST BE COMPLETED AND TESTED PROPERLY PRIOR TO TURNUP TO THE
GOVERNMENT.
2. VENDOR WINNING AWARD IS RESPONSIBLE FOR INSTALLATION AND MAINTENANCE OF
OC-12 SERVICE IAW THE UNIQUE INSTALLATION FACTORS.
3. INSIDE WIRING IS AUTHORIZED IAW WITH THE UNIQUE INSTALLATION FACTORS.
4. VENDOR MUST COORDINATE SITE VISIT WITH POC'S 72 HRS IN ADVANCE PRIOR TO
REQUIRING ACCESS TO FACILITIES AT BOTH USER LOCATIONS.
5. ALL EQUIPMENT AND CIRCUIT PROBLEMS WILL BE REPORTED BY PHONE TO THE CONUS
IP BACKBONE ENGINEERING AND IMPLEMENTATION GROUP, SCOTT AFB.
M. ADDITIONAL INFORMATION:
3. TSR NUMBER: SG13AUG196267B
4. CCSD: DIYU6UDL
Z. DITCO CONTACT:
Edward Midkiff
618-418-6481
Edward.w.midkiff.civ@mail.mil
Angelina Hutson
DITCO Contracting Officer
Unless otherwise specified, all other terms and conditions are unchanged.
Paragraph E.SERVICE DATE change from:
Nov 3, 2020
To:
Dec 22, 2020
Paragraph V.QUOTE DUE DATE AND TIME change from:
Jul 9, 2020 12:00:00 PM CDT
Aug 24, 2020 12:00:00 PM CDT
Location B, UNIQUE INSTALLATION FACTORS change from:
UNIQUE INST FACT:
(1) COMMERCIAL FIBER POINT OF PRESENCE (COMMERCIAL CARRIER SYSTEM)
(2) FIBER CABLE X-CONNECT, IN-HOUSE, INSIDE WIRE, SINGLE-MODE, 1310NM, TELCO
AMPLIFYING INFO: A. VENDOR IS RESPONSIBLE FOR INSTALLATION AND MAINTENANCE OF SINGLE MODE FIBER
FROM THE DROP SIDE OF THE COMMERCIAL FIBER POINT OF PRESENCE [FIBER DISTRIBUTION PANEL (FDP)] BLDG
34500, ROOM 105 (NETWORK ROOM) TO THE LINE SIDE OF THE DISA IE1 PROVIDED FIBER TERMINATING PATCH
PANEL INSTALLED IN THE MSPP SUITE (UMSWGOR030) BLDG 34500, ROOM 105 (NETWORK ROOM). TERMINATE
WITH "SC" CONNECTORS TO DISA PROVIDED FIBER TERMINATING PATCH PANEL.
B. VENDOR MUST PROVIDE FIBER STRANDS FROM THEIR POINT OF PRESENCE TO THE MSPP SUITE WITHOUT
SPLICING AND OR USE OF CONNECTORS TO CONNECT 2 OR MORE FIBER STRANDS MEANING THE FIBER CANNOT
BE BROKEN IN THE MIDDLE AND MUST BE CONTINUOUS.
C. THE CIRCUIT MUST BE TAGGED WITH THE VENDOR'S CIRCUIT ID AS APPLICABLE AT THE DROP SIDE OF THEIR
POINT OF PRESENCE (FIBER DISTRIBUTION PANEL) BLDG 34500, ROOM 105 (NETWORK ROOM). ADDITIONALLY, VENDOR MUST SHOW SITE PERSONNEL LISTED ON THIS ORDER THE EXACT TERMINATION POINT WHEN SERVICE
IS COMPLETE.
D. VENDOR MUST SCHEDULE/COORDINATE WITH THE POC'S LISTED ON THIS ORDER 72 HOURS IN ADVANCE PRIOR
TO SITE SURVEYS OR INSTALLATIONS.
(A) EQUIPMENT INFORMATION: COMMERCIAL FIBER POINT OF PRESENCE
(B) ELECTRICAL: OPTICAL; PHYSICAL: SC;
AMPLIFYING INFO: A. VENDOR IS RESPONSIBLE FOR INSTALLATION AND MAINTENANCE OF SINGLE MODE FIBER
FROM THE DROP SIDE OF THE COMMERCIAL FIBER POINT OF PRESENCE [FIBER DISTRIBUTION PANEL (FDP)] BLDG
34500, ROOM 105 (NETWORK ROOM) TO THE LINE SIDE OF THE DISA IE1 PROVIDED FIBER TERMINATING PATCH
PANEL INSTALLED IN THE MSPP SUITE (UMSWGOR030) BLDG 34500, ROOM 120. TERMINATE WITH "SC"
CONNECTORS TO DISA PROVIDED FIBER TERMINATING PATCH PANEL.
B. VENDOR MUST PROVIDE FIBER STRANDS FROM THEIR POINT OF PRESENCE TO THE MSPP SUITE WITHOUT
SPLICING AND OR USE OF CONNECTORS TO CONNECT 2 OR MORE FIBER STRANDS MEANING THE FIBER CANNOT
BE BROKEN IN THE MIDDLE AND MUST BE CONTINUOUS.
C. THE CIRCUIT MUST BE TAGGED WITH THE VENDOR'S CIRCUIT ID AS APPLICABLE AT THE DROP SIDE OF THEIR
POINT OF PRESENCE (FIBER DISTRIBUTION PANEL) BLDG 34500, ROOM 105 (NETWORK ROOM). ADDITIONALLY, VENDOR MUST SHOW SITE PERSONNEL LISTED ON THIS ORDER THE EXACT TERMINATION POINT WHEN SERVICE
IS COMPLETE.
D. VENDOR MUST SCHEDULE/COORDINATE WITH THE POC'S LISTED ON THIS ORDER 72 HOURS IN ADVANCE PRIOR
TO SITE SURVEYS OR INSTALLATIONS.
Location B, INSIDE WIRE INSTALLATION / MAINTENANCE REQUIRED change from:
CPIWI-NO/CPIWM-NO
CPIWI-YES/CPIWM-YES
File details come from the government source that posted it. Updated .