HC101319QA591-0001.v0.pdf
PDF 15 KB Posted
- Solicitation number
- HC101319QA591
- Issued by
-
Defense Information Systems Agency
View the file
Other files
| File | Type | Posted |
|---|---|---|
| - ~HC101319QA591.v1 Contents.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
IQO INQUIRY
FM: PL8211
TO: Contractors
DATE (MM/DD/YYYY): 11/19/2019
SUBJECT: HC101319QA591-0001 Amend: 0001
A. TYPE ACTION: ADMIN AMEND
1. PURPOSE: DUE TO ISSUES WITH POSTING THE SOLICITATION TO BETA.SAM.GOV, WE
ARE AMENDING THE SOLICITATION TO EXTEND THE PROPOSAL DUE DATE TO 19 DEC 2019
AND SERVICE DATE TO BE MET IS NOW 06 APR 2020.
RECAP:
1. SUBMIT A QUOTE TO PROVIDE, INSTALL, AND MAINTAIN A LEASED TAIL 40MB ETHERNET
VPN ACCESS BETWEEN THE COMMERCIAL DEMARK (CCI) AT BLDG 40, ROOM B-1218,
DENVER FEDERAL CENTER, LAKEWOOD, CO. AND THE COMMERCIAL DEMARK AT BLDG
200, COMPUTER ROOM 2A, 3326 GENERAL HUDNELL DRIVE SAN ANTONIO, TX 78226-1834.
****SEE UNIQUE INSTALL FACTORS.****
2. REVALIDATE TSP
3. EACH CONTRACTOR IS RESPONSIBLE FOR READING AND COMPLYING WITH ALL
TECHNICAL ASPECTS OF THIS SOLICITATION, TO INCLUDE READING AND AGREEING
WITH THE STANDARD PROVISIONS, ATTACHMENTS LISTING SPECIFIC TECHNICAL
REQUIREMENTS, PRICE QUOTE REQUIREMENTS, AND REQUESTED SERVICE DATE.
FAILURE TO READ AND ADHERE TO ANY PORTION OF THE INQUIRY SHALL RENDER THE
QUOTE NON-COMPLIANT AND RESULT IN IT BEING EXCLUDED FROM EVALUATION AND
AWARD.
4. THE SERVICE DATE TO BE MET IS: 06 APR 20 (SIP). THE GOVERNMENT ASSUMES
THAT CONTRACTORS HAVE CONSIDERED ALL ISSUES THAT MAY IMPACT THE SERVICE
DATE. THE GOVERNMENT MAY CANCEL, TERMINATE, OR REQUEST CONSIDERATION
IAW STANDARD PROVISION 42 FOR FAILURE TO MEET CONTRACTUAL SERVICE DATE OR
COMPLY WITH ANY CONTRACT TERMS OR CONDITIONS.
5. CONTRACTORS SHALL SUBMIT QUOTES IAW STANDARD PROVISION 04. QUOTES SHALL
INCLUDE SUFFICIENT DETAIL FOR EFFECTIVE EVALUATION AND SHOULD NOT SIMPLY
REPHRASE OR RESTATE THE GOVERNMENT REQUIREMENTS. QUOTE MUST PROVIDE
CONVINCING RATIONALE TO ADDRESS HOW THE CONTRACTOR INTENDS TO MEET THE
REQUIREMENT. IN RESPONSE TO THIS SOLICITATION, NO TERMS OR CONDITIONS PLACED
UPON THE GOVERNMENT, NOR ASSUMPTIONS WILL BE ACCEPTED. CONTRACTORS
ARE ENCOURAGED TO SUBMIT QUESTIONS AND REQUEST CLARIFICATION OF THE
REQUIREMENT(S) BEFORE SUBMITTING QUOTES. QUESTIONS SHALL BE SUBMITTED TO
CONTRACT SPECIALIST AND CONTRACTING OFFICER DURING THE SOLICITATION PHASE
ONLY, AND RESPONSES FOR ALL INTERESTED PARTIES WILL BE POSTED TO FEDBIZOPPS.
HC101319QA591-0001
6. REQUEST VENDOR WINNING AWARD CONDUCT WALK-THROUGH SITE SURVEY PRIOR TO
INSTALLATION AT BOTH SITES.
7. VENDOR MUST PERFORM ACCEPTANCE TESTING IN ACCORDANCE WITH CUSTOMER
CIRCUIT SPECIFICATIONS PRIOR TO CIRCUIT HAND OFF.
8. VENDOR MUST PROVIDE THE LONG HAUL CIRCUIT NO., LOCAL CIRCUIT IDENTIFIER AND
1-800 TROUBLE REPORTING NUMBER FOR EACH END LOCATION AS
APPLICABLE TO THE ACCEPTING AUTHORITY PRIOR TO THE GOVERNMENT ACCEPTING
SERVICE.
9. VENDOR MUST TAG CIRCUIT AT EACH END LOCATION WITH CIRCUIT ID AND CCSD, AND
SHOW GOVERNMENT SITE PERSONNEL EXACT TERMINATION POINT.
10. THIS IS A REAWARD OF A CURRENT SERVICE, (CSA GINT 000033EBM). IF THE
INCUMBENT QUOTE IS EVALUATED AS THE LOWEST PRICE TECHNICAL ACCEPTABLE,
THE CURRENT CSA WILL BE ADMINISTRATIVELY DISCONTINUED WITHIN 30 DAYS OF
INCUMBENT CONTRACTOR RECEIVING AWARD. INCUMBENT CONTRACTORS SHALL
SUBMIT NOTICE OF COMPLETION (NOC) WITHIN 30 DAYS.
M. ADDITIONAL INFORMATION:
3. TSR NUMBER: CN18FEB190004A
4. CCSD: XXXXBC47
Z. DITCO CONTACT:
Edward Whittaker
618-418-6607 edward.d.whittaker.civ@mail.mil
Dale L. Rupright
DITCO Contracting Officer
Add the following:
LOCATION OF TERMINATION A:
ADDRESS: BLDG 40, ROOM B-1218, DENVER FEDERAL CENTER,
LAKEWOOD, CO.
ROOM: B-1218
LOCATION: CCI
EXTENSION OF TELECOMMUNICATIONS SERVICE: All facilities between vendor's commercial communications interface point and termination location shall be provided by vendor. All cables shall be run in accordance with local site standards
INTERFACE: (PHYSICAL) SC; (ELECTRICAL) ETHERNET GIGABIT ETHERNET 1000BASE SX
DEMARK:
NPA/NXX: 303/969
UNIQUE INSTALLATION FACTORS: (1) FOR LOCAL COMMUNICATIONS UNIT: THE LOCAL COMM UNIT WILL
EXTEND SERVICE FROM THE FIBER PATCH PANEL IN BLDG 710A, ROOM 257 TO THE SITE PROVIDED PATCH PANEL
BLDG 40, ROOM B-1218 USING MULTI-MODE FIBER. FOR CIRCUIT ACTIVATION ASSISTANCE CONTACT DISA CONUS
CORE SERVICE ACTIVATION TEAM (CSAT) AT DSN 770-8880, COML 618-220-8880. DISA REQUIRES THAT CIRCUIT
VENDOR OBTAIN A SIGNATURE FROM A RESPONSIBLE SITE POC CERTIFYING THAT THE VENDOR
PROVIDED THE CONNECTIVITY AND THAT THE CIRCUIT IS PROPERLY TAGGED WITH CIRCUIT ID AND TSR
NUMBER OR CCSD.
(2) FOR THE VENDOR: VENDOR WILL DELIVER SERVICE TO THE COMMERCIAL DEMARC IDENTIFIED IN THE
DOCUMENT. FOR THE VENDOR: VENDOR WILL DELIVER SERVICE TO THE COMMERCIAL DEMARC IDENTIFIED IN
THE DOCUMENT. REQUEST VENDOR HAND OFF AS MULTIMODE FIBER.
INSIDE WIRE INSTALLATION / MAINTENANCE REQUIRED: CPIWI-NO/CPIWM-NO
CONTACT: PRI: DENNIS HUNTLEY
C303-235-4869, CELL 303-274-0111
EMAIL: DENNIS.HUNTLEY@FEMA.DHS.GOV
ALT: DAVID BERRY
C303-235-4621, CELL 303-204-0142
EMAIL: DAVID.BERRY@FEMA.DHS.GOV
Add the following:
LOCATION OF TERMINATION B:
ADDRESS: BLDG 200, COMPUTER ROOM 2A
3326 GENERAL HUDNELL DRIVE
SAN ANTONIO, TX 78226-1834
ROOM: COMPUTER ROOM 2A
LOCATION: CCI
EXTENSION OF TELECOMMUNICATIONS SERVICE: All facilities between vendor's commercial communications interface point and termination location shall be provided by vendor. All cables shall be run in accordance with local site standards
INTERFACE: GIGABIT ETHERNET; ELECTRICAL: 1000BASE-LX;PHYSICAL: SNAP CLICK (SC);; (PHYSICAL) SNAP CLICK
(SC);(ELECTRICAL) 1000BASE-LX
DEMARK: BLDG 200, COMPUTER ROOM 2A
3326 GENERAL HUDNELL DRIVE
SAN ANTONIO, TX 78226-1834
NPA/NXX: 210/922
UNIQUE INSTALLATION FACTORS: (1) COMMERCIAL DEMARC
1. THE CIRCUIT WILL NEED TO BE EXTENDED FROM BLDG 200, COMPUTER ROOM 2A (COMMERCIAL VENDOR DROP
OFF LOCATION) TO THE DISA IPT-PE ROUTER AT BLDG. 200, COMPUTER ROOM 2A.
2. FOR LOCAL COMMUNICATIONS UNIT: THE LOCAL COMM UNIT WILL EXTEND SERVICE FROM THE COMMERCIAL
DEMARC TO THE SERVICE DELIVERY POINT (SDP). FOR CIRCUIT ACTIVATION ASSISTANCE CONTACT DISA CONUS
CORE SERVICE ACTIVATION TEAM (CSAT) AT DSN 770-8880,
COML 618-220-8880. DISA REQUIRES THAT CIRCUIT VENDOR OBTAIN A SIGNATURE FROM A RESPONSIBLE SITE
POC CERTIFYING THAT THE VENDOR
PROVIDED THE CONNECTIVITY AND THAT THE CIRCUIT IS PROPERLY TAGGED WITH CIRCUIT ID AND TSR NUMBER
OR CCSD.
3. FOR THE VENDOR: VENDOR WILL DELIVER SERVICE TO THE COMMERCIAL DEMARC IDENTIFIED IN THE
DOCUMENT.
INSIDE WIRE INSTALLATION / MAINTENANCE REQUIRED: CPIWI-NO/CPIWM-NO
CONTACT: PRI POC: LESTER MOSES, C210-672-3100, D672-3100
EMAIL: LESTER.MOSES4.CIV@MAIL.MIL
ALT POC: RICHARD MONCADA, C210-925-9288, D945-9288
EMAIL: RICHARD.MONCADA1.CIV@MAIL.MIL
ALT POC: DONALD SIMPSON, C210-925-9288, D945-9288
EMAIL: DONALD.E.SIMPSON.CIV@MAIL.MIL
ORG EMAIL: DISA.MEADE.SE.MBX.DATA-CENTER-SEL4-INFRASTRUC
TURE-SUPPORT-NETW@MAIL.M
IL
File details come from the government source that posted it. Updated .