IQO INQUIRY

FM: PL8211

TO: Contractors

DATE (MM/DD/YYYY): 2/9/2020

SUBJECT: HC101319QA450-0001 Amend: 0001

A. TYPE ACTION: AMEND

1. PURPOSE: THE PURPOSE OF THIS AMENDMENT IS TO UPDATE LOC Z ADDRESS TO

SHOW "(BLDG) 271; (RM) B1-238; (FL) 1ST; 400 NORTH DOUGLAS STREET, EL SEGUNDO, CA 90245-2808," VICE "(BLDG) 271; (RM) B1-238; (FL) 1ST; 400 NORTH DOUGLAS AVENUE, EL

SEGUNDO, CA 90245-2808"

ALL ELSE REMAINS THE SAME.

1. PROVIDE, INSTALL, AND MAINTAIN A 1GB VPN AT (BLDG) 100; (RM) TELCO; (FL) BAS; 100

N. SEPULVEDA BLVD; EL SEGUNDO, CA, 90245 TO BLDG 271, 1ST FLOOR,ROOM B1-238, 400

NORTH DOUGLAS AVENUE, EL SEGUNDO, CA 90245-2808.

A. SEE UNIQUE INSTALL FACTORS AND TESTING REQUIREMENTS

B. CUSTOMER WILL ACCEPT SOONEST POSSIBLE SERVICE DATE.

2. EACH CONTRACTOR IS RESPONSIBLE FOR READING AND COMPLYING WITH ALL

TECHNICAL ASPECTS OF THIS SOLICITATION, TO INCLUDE READING AND AGREEING WITH

THE STANDARD PROVISIONS,

ATTACHMENTS LISTING SPECIFIC TECHNICAL REQUIREMENTS, PRICE QUOTE

REQUIREMENTS, AND REQUESTED SERVICE DATE. FAILURE TO READ AND ADHERE TO

ANY PORTION OF THE INQUIRY SHALL RENDER THE QUOTE NON-COMPLIANT AND RESULT

IN IT BEING EXCLUDED FROM EVALUATION AND AWARD.

3. THE SERVICE DATE TO BE MET IS: 18 MAY 20 (SIP). THE GOVERNMENT ASSUMES

THAT CONTRACTORS HAVE CONSIDERED ALL ISSUES THAT MAY IMPACT THE SERVICE

DATE. THE GOVERNMENT MAY CANCEL, TERMINATE, OR REQUEST CONSIDERATION

IAW STANDARD PROVISION 42 FOR FAILURE TO MEET CONTRACTUAL SERVICE DATE OR

COMPLY WITH ANY CONTRACT TERMS OR CONDITIONS.

4. CONTRACTORS SHALL SUBMIT QUOTES IAW STANDARD PROVISION 04. QUOTES SHALL

INCLUDE SUFFICIENT DETAIL FOR EFFECTIVE EVALUATION AND SHOULD NOT SIMPLY

REPHRASE OR RESTATE THE GOVERNMENT REQUIREMENTS. QUOTE MUST PROVIDE

CONVINCING RATIONALE TO ADDRESS HOW THE CONTRACTOR INTENDS TO MEET THE

REQUIREMENT. IN RESPONSE TO THIS SOLICITATION, NO TERMS OR CONDITIONS PLACED

UPON THE GOVERNMENT, NOR ASSUMPTIONS WILL BE ACCEPTED. CONTRACTORS

ARE ENCOURAGED TO SUBMIT QUESTIONS AND REQUEST CLARIFICATION OF THE

REQUIREMENT(S) BEFORE SUBMITTING QUOTES. QUESTIONS SHALL BE SUBMITTED TO

HC101319QA450-0001

CONTRACT SPECIALIST AND CONTRACTING OFFICER DURING THE SOLICITATION PHASE

ONLY, AND RESPONSES FOR ALL INTERESTED PARTIES WILL BE POSTED TO BETA.SAM.

M. ADDITIONAL INFORMATION:

3. TSR NUMBER: NH31JAN196644

4. CCSD: XXXX7WGJ

Z. DITCO CONTACT:

JOHN WARNER

618-418-6466 john.d.warner28.civ@mail.mil

KEVIN L. KNOWLES

DITCO Contracting Officer

Unless otherwise specified, all other terms and conditions are unchanged.

Paragraph E.SERVICE DATE change from:

May 18, 2020

To:

Mar 31, 2020

Paragraph M.3.TSR NUMBER change from:

NH31JAN196644A

NH31JAN196644

Paragraph M.10.TESTING REQUIREMENTS change from:

A. VENDOR WILL PERFORM ACCEPTANCE TESTING IN ACCORDANCE WITH EITHER

RFC-6815 OR ITU-T Y.1564. VENDOR MUST TEST THE CIRCUIT FOR 24

HOURS IAW ITU-T.Y.1564 SPECIFICALLY, FRAME SIZES OF

64,128,256,512,1024,1280 AND 1518 BYTES MUST BE USED. THE TEST

MUST VERIFY LENGTH OF RECEIVED FRAMES, INDICATE NUMBER OF FRAMES

DROPPED, NUMBER OF FRAMES RECEIVED OUT OF ORDER, AND DUPLICATE

FRAMES. TESTS MUST BE BI-DIRECTIONAL USING THE SAME DATA RATE IN

EACH DIRECTION. BURST TESTS MUST BE RUN TO DETERMINE MINIMUM

INTERVAL BETWEEN FRAMES THAT CAN BE PROCESSED WITHOUT FRAME LOSS.

A THROUGHPUT TEST IS REQUIRED INDICATING THE FASTEST RATE AT

WHICH TEST FRAMES CAN BE TRANSMITTED WITHOUT FRAME LOSS. A

SEPARATE THROUGHPUT TEST MUST BE RUN WITH FRAMES ADDRESSED TO THE

HARDWARE BROADCAST ADDRESS CONSTITUTING AT LEAST 1% OF THE TEST

STREAM AND BE EVENLY DISTRIBUTED THROUGHOUT THE TEST.

B. CIRCUIT SPECIFICATIONS CONTINUED: A LATENCY TEST MUST BE RUN FOR

A PERIOD OF NO LESS THAN 15 MINUTES, AND REPEATED NO LESS THAT 20

TIMES. THE TEST STREAM FOR THE LATENCY TEST SHOULD BE RUN AT

THE THROUGHPUT RATE FOR CORRESPONDING FRAME SIZES FROM THE

THROUGHPUT TEST. END TO END LATENCY WILL BE CALCULATED AS THE

AVERAGE OVER THE 20 TEST RUNS. FRAME LOSS RATE TESTS SHOULD BE

RUN AT THE FRAME RATE CORRESPONDING TO THE MAXIMUM FRAME RATE,

AND REDUCED BY 10% INTERVALS UNTIL THERE ARE AT LEAST TWO

CONSECUTIVE RUNS IN WHICH NO FRAMES ARE LOST.THROUGHPUT TEST

RESULTS: PASSING RATE 100% FOR ALL FRAME BYTE SIZES EXERCISED.

FRAME LOSS RATE (%) RESULTS: FRAME LOSS RATE LESS THAN 0.01% FOR

ALL FRAME BYTE SIZES EXERCISED. LATENCY WILL BE MEASURED WILL BE

ACCORDING TO THE FOLLOWING MAXIMUM TRANSMISSION DELAY FOR ANY

CIRCUIT UP TO 500 MILES AIR-MILES IN LENGTH SHALL BE NO GREATER

THAN 13MS ONE-WAY AND ANY POINT-TO-POINT CIRCUIT LONGER THAN 500

AIR-MILES SHALL BE NO GREATER THAN 50MS ONE WAY WITHIN THE 48

CONTINENTAL STATES. ANY APS SWITCHOVER SHALL TAKE LESS THAN 50

MILLISECONDS MONTHLY AVAILABILITY SHALL BE NO LESS THAN 99.5%.

To:

A. VENDOR WILL PERFORM ACCEPTANCE TESTING IN ACCORDANCE WITH EITHER RFC-6815 OR ITU-T Y.1564.

VENDOR MUST TEST THE CIRCUIT FOR 24 HOURS IAW ITU-T.Y.1564 SPECIFICALLY, FRAME SIZES OF

64,128,256,512,1024,1280 AND 1518 BYTES MUST BE USED. THE TEST MUST VERIFY LENGTH OF RECEIVED FRAMES, INDICATE NUMBER OF FRAMES DROPPED, NUMBER OF FRAMES RECEIVED OUT OF ORDER, AND DUPLICATE

FRAMES. TESTS MUST BE BI-DIRECTIONAL USING THE SAME DATA RATE IN EACH DIRECTION. BURST TESTS MUST

BE RUN TO DETERMINE MINIMUM INTERVAL BETWEEN FRAMES THAT CAN BE PROCESSED WITHOUT FRAME

LOSS. A THROUGHPUT TEST IS REQUIRED INDICATING THE FASTEST RATE AT WHICH TEST FRAMES CAN BE

TRANSMITTED WITHOUT FRAME LOSS. A SEPARATE THROUGHPUT TEST MUST BE RUN WITH FRAMES ADDRESSED

TO THE HARDWARE BROADCAST ADDRESS CONSTITUTING AT LEAST 1% OF THE TEST STREAM AND BE EVENLY

DISTRIBUTED THROUGHOUT THE TEST.

B. CIRCUIT SPECIFICATIONS CONTINUED: A LATENCY TEST MUST BE RUN FOR A PERIOD OF NO LESS THAN 15

MINUTES, AND REPEATED NO LESS THAT 20 TIMES. THE TEST STREAM FOR THE LATENCY TEST SHOULD BE RUN

AT THE THROUGHPUT RATE FOR CORRESPONDING FRAME SIZES FROM THE

THROUGHPUT TEST. END TO END LATENCY WILL BE CALCULATED AS THE AVERAGE OVER THE 20 TEST RUNS.

FRAME LOSS RATE TESTS SHOULD BE RUN AT THE FRAME RATE CORRESPONDING TO THE MAXIMUM FRAME

RATE, AND REDUCED BY 10% INTERVALS UNTIL THERE ARE AT LEAST TWO

CONSECUTIVE RUNS IN WHICH NO FRAMES ARE LOST.THROUGHPUT TEST RESULTS: PASSING RATE 100% FOR

ALL FRAME BYTE SIZES EXERCISED. FRAME LOSS RATE (%) RESULTS: FRAME LOSS RATE LESS THAN 0.01% FOR

ALL FRAME BYTE SIZES EXERCISED. LATENCY WILL BE MEASURED WILL BE ACCORDING TO THE FOLLOWING

MAXIMUM TRANSMISSION DELAY FOR ANY CIRCUIT UP TO 500 MILES AIR-MILES IN LENGTH SHALL BE NO GREATER

THAN 13MS ONE-WAY AND ANY POINT-TO-POINT CIRCUIT LONGER THAN 500 AIR-MILES SHALL BE NO GREATER

THAN 50MS ONE WAY WITHIN THE 48

CONTINENTAL STATES. ANY APS SWITCHOVER SHALL TAKE LESS THAN 50 MILLISECONDS MONTHLY AVAILABILITY

SHALL BE NO LESS THAN 99.5%.

Location A, UNIQUE INSTALLATION FACTORS change from:

1) FOR LOCAL COMMUNICATIONS UNIT: THE LOCAL COMM UNIT

WILL ASSIST SST IN EXTENDING SERVICE FROM THE COMMERCIAL

DEMARC TO THE SERVICE DELIVERY POINT (SDP).

FOR CIRCUIT ACTIVATION ASSISTANCE CONTACT DCP

COMMERICIAL ACTIVATION TEAM (CAT) AT D312-850-0820,

C614-692-0820.

DISA REQUIRES THAT CIRCUIT VENDOR OBTAIN A SIGNATURE

FROM A RESPONSIBLE SITE POC CERTIFYING THAT THE VENDOR

PROVIDED THE CONNECTIVITY AND THAT THE CIRCUIT IS PROPERLY

TAGGED WITH CIRCUIT ID AND TSR NUMBER OR CCSD

2) FOR SST: PROVIDE NECESSARY EQUIPMENT AND EXTEND SERVICE

FROM THE COMMERCIAL DEMARC TO THE SDP.

3) FOR THE VENDOR: VENDOR WILL DELIVER SERVICE TO THE

COMMERCIAL DEMARC IDENTIFIED IN THE DOCUMENT.

4) COML ACCESS: WILL NOT LEAK CAT - 5

5) INTERFACE: ELECTRICAL: 1000BASE-LX; PHYSICAL: LC; (PHYSICAL) LC;

(ELECTRICAL) 1000BASE-LX

1) FOR LOCAL COMMUNICATIONS UNIT: THE LOCAL COMM UNIT WILL ASSIST SST IN EXTENDING SERVICE FROM

THE COMMERCIAL DEMARC TO THE SERVICE DELIVERY POINT (SDP). FOR CIRCUIT ACTIVATION ASSISTANCE

CONTACT DCP COMMERICIAL ACTIVATION TEAM (CAT) AT D312-850-0820,

C614-692-0820. DISA REQUIRES THAT CIRCUIT VENDOR OBTAIN A SIGNATURE FROM A RESPONSIBLE SITE POC

CERTIFYING THAT THE VENDOR PROVIDED THE CONNECTIVITY AND THAT THE CIRCUIT IS PROPERLY TAGGED

WITH CIRCUIT ID AND TSR NUMBER OR CCSD.

2) FOR SST: PROVIDE NECESSARY EQUIPMENT AND EXTEND SERVICE FROM THE COMMERCIAL DEMARC TO THE

SDP.

3) FOR THE VENDOR: VENDOR WILL DELIVER SERVICE TO THE COMMERCIAL DEMARC IDENTIFIED IN THE

DOCUMENT.

4) COML ACCESS: WILL NOT LEAK CAT - 5

Location A, INSIDE WIRE INSTALLATION / MAINTENANCE REQUIRED change from:

INSIDE WIRE INSTL/MAINT: CPIWI-YES/CPIWM-NO

CPIWI-YES/CPIWM-NO

Location A, TERMINAL EQUIPMENT change from:

REUSE: CISCO ROUTER 2921/K9 CISCO 9010 IPT-PE ASR ROUTER (DISA PROVIDED)

RE USE: CISCO ROUTER 2921/K9 CISCO 9010 IPT-PE ASR ROUTER (DISA PROVIDED)

Location B, LOCATION OF TERMINATION B change from:

ADDRESS: 271,400 NORTH DOUGLAS AVENUE, ELSEGUNDO, CA 90245-2808

ROOM: 1ST FLOOR ROOM B1-238;

LOCATION: LSAGLAFB

ADDRESS: BLDG 271,400 NORTH DOUGLAS STREET, EL SEGUNDO, CA 90245-2808

ROOM: 1ST FLOOR ROOM B1-238;

LOCATION: LSAGLAFB

Location B, DEMARK change from:

BLDG 271

1ST FLOOR

ROOM B1-238

400 NORTH DOUGLAS AVENUE

EL SEGUNDO, CA 90245-2808

PRI: TODD BARTON, D633-3313, C310-653-3313

EMAIL: TODD.BARTON.1@US.AF.MIL

ORG EMAIL: SMC.TSR.TSO@US.AF.MIL

To:

BLDG 271

1ST FLOOR

ROOM B1-238

400 NORTH DOUGLAS STREET

EL SEGUNDO, CA 90245-2808

PRI: TODD BARTON, D633-3313, C310-653-3313

EMAIL: TODD.BARTON.1@US.AF.MIL

ORG EMAIL: SMC.TSR.TSO@US.AF.MIL

Location B, UNIQUE INSTALLATION FACTORS change from:

1) FOR LOCAL COMMUNICATIONS UNIT: THE LOCAL COMM UNIT

WILL EXTEND SERVICE FROM THE COMMERCIAL DEMARC TO THE

SERVICE DELIVERY POINT (SDP).

FOR CIRCUIT ACTIVATION ASSISTANCE CONTACT DCP

COMMERICIAL ACTIVATION TEAM (CAT) AT D312-850-0820,

C614-692-0820.

DISA REQUIRES THAT CIRCUIT VENDOR OBTAIN A SIGNATURE

FROM A RESPONSIBLE SITE POC CERTIFYING THAT THE VENDOR

PROVIDED THE CONNECTIVITY AND THAT THE CIRCUIT IS PROPERLY

TAGGED WITH CIRCUIT ID AND TSR NUMBER OR CCSD

2) FOR THE VENDOR: VENDOR WILL DELIVER SERVICE TO THE

COMMERCIAL DEMARC IDENTIFIED IN THE DOCUMENT. 3) AN ESCORT IS REQUIRED. ALL VISITORS MUST

CONTACT THE

SITE POC'S FOR ACCESS AT LEAST 48 HOURS PRIOR TO ANY SITE

VISITS. THIS ADVANCE NOTICE WILL BE WAIVED IN THE EVENT OFA CIRCUIT OUTAGE.

4) THE APPROXIMATE DISTANCE FROM THE COMMERCIAL DEMARC

(BLDG 271, ROOM B1238) TO THE DISA HUB ROUTER (BLDG 271, ROOM B1239) IS ABOUT 50 FEET.

1) FOR LOCAL COMMUNICATIONS UNIT: THE LOCAL COMM UNIT WILL EXTEND SERVICE FROM THE COMMERCIAL

DEMARC TO THE SERVICE DELIVERY POINT (SDP). FOR CIRCUIT ACTIVATION ASSISTANCE CONTACT DCP

COMMERICIAL ACTIVATION TEAM (CAT) AT D312-850-0820, C614-692-0820. DISA REQUIRES THAT CIRCUIT VENDOR

OBTAIN A SIGNATURE FROM A RESPONSIBLE SITE POC CERTIFYING THAT THE VENDOR PROVIDED THE

CONNECTIVITY AND THAT THE CIRCUIT IS PROPERLY TAGGED WITH CIRCUIT ID AND TSR NUMBER OR CCSD.

2) FOR THE VENDOR: VENDOR WILL DELIVER SERVICE TO THE COMMERCIAL DEMARC IDENTIFIED IN THE

DOCUMENT.

3) AN ESCORT IS REQUIRED. ALL VISITORS MUST CONTACT THE SITE POC'S FOR ACCESS AT LEAST 48 HOURS

PRIOR TO ANY SITE VISITS. THIS ADVANCE NOTICE WILL BE WAIVED IN THE EVENT OFA CIRCUIT OUTAGE.

4) THE APPROXIMATE DISTANCE FROM THE COMMERCIAL DEMARC (BLDG 271, ROOM B1238) TO THE DISA HUB

ROUTER (BLDG 271, ROOM B1239) IS ABOUT 50 FEET.

Location B, INTERFACE change from:

INTERFACE: 1000BASELX, SM FIBER, SC CONNECTOR

1000BASELX, SM FIBER, SC CONNECTOR

Location B, INSIDE WIRE INSTALLATION / MAINTENANCE REQUIRED change from:

INSIDE WIRE INSTL/MAINT: CPIWI-NO/CPIWM-NO

CPIWI-NO/CPIWM-NO

Location B, TERMINAL EQUIPMENT change from:

COMMERCIAL DEMARK

COMMERCIAL DEMARK; CISCO 9010 IPT-PE ASR ROUTER (DISA PROVIDED)

File details come from the government source that posted it. Updated .