1. SATELLITE OBJECTION: DIVERSITY: SERVICES ARE DUAL SOURCED EAST
AND WEST COASTS, TO MAINTAIN DATA INGEST TO SITE LOGICAL DIVERSITY IS REQUESTED.
2. TEST & ACCEPTANCE INSTRUCTIONS: ITU STANDARD G.828: CIRCUIT
PERFORMANCE WILL BE IN ACCORDANCE WITH THIS STANDARD.
ITU STANDARD G.707: THE IDENTIFICATION OF THE POH FUNCTIONS AND FRAMING FOR STM-N SERVICES WILL BE IN ACCORDANCE WITH ITU STANDARD G. 707. FOR EXAMPLE: THE FOLLOWING OVERHEAD BYTES C2, F2, F3, H4, AND K3, SHALL BE AVAILABLE FOR USE BY THE CUSTOMER.
ALL OF THESE BYTES ARE DEFINED FOR USE BY PATH TERMINATION
EQUIPMENT FUNCTIONS.
ITU STANDARD M.2101: THE VENDOR WILL PERFORM A 72-HOUR TEST IN
ACCORDANCE WITH ITU STANDARD M.2101 AND THE STANDARDS CALLED OUT IN THIS DOCUMENT.
VENDOR WILL PROVIDE THE FOLLOWING DATA
A. PATH ALLOCATION (%)
B. EXPLANATION OF PATH ALLOCATION COMPUTATION
C. S1 LIMIT FOR ERRORED SECONDS (ES) AND SEVERELY ERRORED
SECONDS (SES)
D. S2 LIMIT FOR ES AND SES.
HTTPS://EURPORTAL.DISA.MIL/PAGES/DEFAULT.ASPX
E. BISPO LIMIT FOR ES AND SES
F. TOTAL NUMBER OF ES DURING THE 72-HOUR TEST FROM BOTH SITES
G. TOTAL NUMBER OF SES DURING THE 72-HOUR TEST FROM BOTH SITES
H. TOTAL NUMBER OF UNAVAILABLE SECONDS (UAS) DURING THE 72-HOUR
TEST FROM BOTH SITES
I. TOTAL NUMBER OF AU-POINTER ADJUSTMENTS/PJE ARE TO BE LESS
THAN 200 PER HOUR, PER DISA END EQUIPMENT REQUIREMENTS
J. THERE SHALL BE LESS THAN 4 PATTERN LOSS AND LOSS OF FRAME
EVENTS PER 24-HOUR PERIOD DURING TEST
K. S1 OVERHEAD BYTE RECEIVED (RX) VALUES FOR SITE A AND SITE B
L. OPTICAL RECEIVE POWER FOR SITE A (RX) AND SITE B (RX)
M. EVIDENCE THAT THE FOLLOWING BYTES ARE PASSED TRANSPARENTLY
VIA EACH AU4/VC4 CONTAINER PATH
P. REMARKS CONTINUED: I. PROVIDE SCREENSHOTS OF THE TX AND RX
OVERHEAD BYTES AT LOCATION A AND B, AS FOLLOWS
II. SITE A TX VALUES
1. C2= 10
2. F2= 08
3. H4= 06
4. F3= 04
5. K3= 02
III. SITE B TX VALUES
1. C2= 13
2. F2= 11
3. H4= 09
4. F3= 07
AVAILABILITY WILL BE 99.5% OR GREATER FOR 72 HR PERIOD ANY APS
SWITCHOVER SHALL TAKE LESS THAN 50 MILLISECONDS
LATENCY, MEASURED ROUND-TRIP, WILL BE ACCORDING TO THE FOLLOWING GUIDELINES:
WITHIN COUNTRY, LESS THAN 25MS; WITHIN EUROPE, LESS THAN 75MS;
OUTSIDE EUROPE, LESS THAN 150MS
2. TEST EACH OF THE REMAINING AU-4/VC-4 TIMESLOTS FOR 15 MINUTES
AND PROVIDE A REPORT, FOR EACH AU-4/VC-4 TIMESLOT ON THE
FOLLOWING:
ITU STANDARD G.707: THE IDENTIFICATION OF THE
POH FUNCTIONS AND FRAMING FOR STM-N SERVICES WILL BE IN
ACCORDANCE WITH ITU STANDARD G. 707. FOR EXAMPLE: THE FOLLOWING OVERHEAD BYTES C2, F2, F3, H4, K3, AND N1, SHALL BE AVAILABLE FOR USE BY THE CUSTOMER. ALL OF THESE BYTES ARE DEFINED FOR USE BY PATH TERMINATION EQUIPMENT FUNCTIONS
A.TOTAL NUMBER OF ES DURING THE 15 MINUTE TEST FROM BOTH SITES
B.TOTAL NUMBER OF SES DURING THE 15 MINUTE TEST FROM BOTH SITES
C. TOTAL NUMBER OF UNAVAILABLE SECONDS (UAS) DURING THE 15 MINUTE TEST FROM BOTH SITES
D. TOTAL NUMBER OF AU-POINTER ADJUSTMENTS/PJE ARE TO BE LESS THAN
200 PER HOUR, PER DISA END EQUIPMENT REQUIREMENTS
E. THERE SHALL BE LESS THAN 4 PATTERN LOSS AND/OR LOSS OF FRAME EVENTS PER 24-HOUR DURING TEST
K. S1 OVERHEAD BYTE RECEIVED (RX) VALUES FOR SITE A AND SITE B
L. OPTICAL RECEIVE POWER FOR SITE A (RX) AND SITE B (RX)
M. EVIDENCE THAT THE FOLLOWING BYTES ARE PASSED TRANSPARENTLY VIA ALL AU4/VC4 PATHS:
I. PROVIDE SCREENSHOTS OF THE TX AND RX OVERHEAD BYTES AT
LOCATION A AND B, AS FOLLOWS:
II. SITE A TX VALUES
1. C2= 10
2. F2= 08
3. H4= 06
4. F3= 04
5. K3= 02
III. SITE B TX VALUES
1. C2= 13
2. F2= 11
3. H4= 09
4. F3= 07
5. K3= 05
AVAILABILITY WILL BE 99.5% OR GREATER FOR 2 HR PERIOD ANY APS
SWITCHOVER SHALL TAKE LESS THAN 50 MILLISECONDS.
LATENCY, MEASURED ROUND-TRIP, WILL BE ACCORDING TO THE FOLLOWING
GUIDELINES: WITHIN COUNTRY, LESS THAN 25MS; WITHIN EUROPE, LESS THAN 75MS; OUTSIDE EUROPE, LESS THAN 150MS
3. VENDOR TESTING FOR THE OC-192C SERVICE WILL BE CONDUCTED FROM THE COMMERCIAL DEMARC OF SERVICE
POINT-A AND SERVICE POINT-Z; LNGLYAFB, BUILDING