CIRCUIT PARAMETERS FOR SOLICITATION HC101318QB024

CIRCUIT REQUIRES THE FOLLOWING PARAMETERS:

(A) FIBER TERMINATION: FRAME FORMAT: 10GB ETHERNET (OPTICAL

HANDOFF-10GB ETHERNET-LAN-PHY-SINGLE MODE FIBER), 802.3AE,

1310NM. "SC" CONNECTORS.

(B) COMMITTED INFORMATION RATE (CIR) - 10GB.

(C) 10GB ETHERNET - LAN-PHY INTERFACE REQUIRED AT COMMERCIAL

DEMARC AT THE A AND Z LOCATIONS.

(D) ETHERNET FRAME SIZE WILL BE CONFIGURED TO SUPPORT MAXIMUM

TRANSMISSION UNIT (MTU) OF 9192 OCTETS (BYTES).

(E) NO NETWORK INTERFACE UNIT, DEDICATED PATH

(F) GFE CLOCKING: VENDOR ESFU (OR EQUIVALENT) NOT TO BE

ENGINEERED INTO CIRCUIT.

(G) TESTING CRITERIA: VENDOR MUST TEST THE CIRCUIT FOR 24 HOURS

IAW ITU-T.Y.1564 BENCH MARKING CONFIGURATION AND PERFORMANCE OF

ETHERNET SERVICE. NOTE-ETHERNET FRAME SIZE DESIGNATOR 'H' (MTU)

IS EQUAL TO 9192 BYTES.

(H) LINE MUST REMAIN FULLY OPERATIONAL AND AVAILABLE TO USERS 24

HOURS A DAY, SEVEN DAYS PER WEEK, AT LEAST 99.5% OR BETTER.

(I) 1 HOUR RESPONSE TIME TO RESPOND TO CUSTOMER UPON RECIEPT OF

TROUBLE.

(J) VENDOR REQUIRED TO HAVE CIRCUIT VISIBILITY TO ASSIST IN ANY

CIRCUIT OUTAGES.

(K) VENDOR MUST HAVE A 24X7 NETWORK OPERATIONS CENTER.

(L) TELECOMM PROVIDER MUST MAINTAIN OPERATIONS, MAINTENANCE AND

ADMINISTRATION MONITORING OF ETHERNET CIRCUIT IAW ITU-T-Y.1731.

(M) THE COMMERCIAL CIRCUIT WILL BE ACCEPTED ON BEHALF OF THE

GOVERNMENT BY THE DISA GOC IP BACKBONE ENGINEERING AND

IMPLEMENTATION GROUP, SCOTT AFB, IL. (C) 618-220-8627 (D)

770-8627.

(N) VENDOR MUST PROVIDE:

1. THE LONG-HAUL CIRCUIT NO. AND LEC CKT ID'S AS APPLICABLE TO

THE DISA IE161 PROGRAM OFFICE PRIOR TO TURN UP TO THE GOVERNMENT.

PRIMARY: KEN DIEFFENDERFER (301) 225-2416

2. VENDOR WINNING AWARD IS RESPONSIBLE FOR INSTALLATION AND

MAINTENANCE OF 10GBE SERVICE IAW THE UNIQUE INSTALLATION FACTORS.

3. INSIDE WIRING IS AUTHORIZED IAW THE UNIQUE INSTALLATION

FACTORS.

4. VENDOR MUST COORDINATE SITE

VISIT WITH POC'S 72 HOURS IN ADVANCE PRIOR TO REQUIRING ACCESS TO

FACILITIES AT BOTH USER LOCATIONS.

5. ALL EQUIPMENT AND CIRCUIT PROBLEMS WILL BE REPORTED BY PHONE

TO THE DISA GOC IP BACKBONE ENGINEERING AND IMPLEMENTATION GROUP,

SCOTT AFB, IL. PRIMARY: (C) 618-220-9950, (D)770-9950 TOLL FREE:

855-868-9950

6. DD FORM 1368 WILL BE SUBMITTED ON THIS TRUNK IAW DISAC-DITCO

350-135-1 BY RNSOC, SCOTT AFB, IL. GUIDANCE ON SUBMISSION IS

AVAILABLE AT <HTTP://WWW.DITCO.DISA.MIL/ASP/PUBLICATIONS.ASP>

CLICK ON "DISA-DITCO CIRCULAR, 350-135-1, DEFENSE COMMERCIAL

COMMUNICATIONS ACQUISITION PROCEDURES."