About this file

Additional Information

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

WHTMNAFB 29DCCI

(B) UNIQUE INST FACT:

(1) FIBER CABLE X-CONNECT, IN-HOUSE, INSIDE WIRE, SINGLE-MODE, 1310NM, TELCO

(2) TELCO MULTIPLEX (COMMERCIAL FIBER POINT OF PRESENCE) COMMERCIAL CARRIER SYSTEM (LOCAL EXCHANGE CARRIER) PORT: BY LOCAL CARRIER

AMPLIFYING INFO:

A. VENDOR IS RESPONSIBLE FOR INSTALLATION AND MAINTENANCE OF THE SERVICE FROM THE LINE SIDE OF THE DISA IE1 PROVIDED FIBER TERMINATING PATCH PANEL INSTALLED IN THE JUNIPER MX-240 ROUTER SUITE (UJEWWHI040) BLDG 149, ROOM 138 TO THE DROP SIDE OF THE COMMERCIAL FIBER POINT OF PRESENCE FIBER DISTRIBUTION PANEL BLDG 149, ROOM 138 USING SINGLE MODE FIBER. COORDINATE TYPE CONNECTORS TO BE USED FOR TERMINATION TO THE DISA PROVIDED PATCH PANEL.

B. VENDOR MUST COORDINATE WITH GOVERNMENT SITE PERSONNEL TO CONDUCT WALK THROUGH SITE SURVEYS FOR EXACT CABLE FT. FROM THE DISA PROVIDED FIBER TERMINATING PATCH PANEL INSTALLED IN THE JUNIPER MX-240 ROUTER SUITE BLDG 149, ROOM 138 TO THE COMMERCIAL FIBER POINT OF PRESENCE BLDG 149, ROOM 138 C. VENDOR MUST PROVIDE FIBER STRANDS FROM THE DISA PROVIDED FIBER PATCH PANEL INSTALLED IN THE JUNIPER MX-240 ROUTER TO THE COMMERCIAL DEMARC LOCATION WITHOUT SPLICING AND OR USE OF CONNECTORS TO CONNECT 2 OR MORE FIBER STRANDS MEANING THE FIBER CANNOT BE BROKEN IN THE MIDDLE AND MUST BE CONTINUOUS.

D. VENDOR MUST SCHEDULE/COORDINATE WITH THE POC'S LISTED ON THIS ORDER 72 HOURS IN ADVANCE PRIOR TO SITE SURVEYS OR INSTALLATIONS.

(C) INSIDE WIRE INSTL/MAINT: CPIWI-YES/CPIWM-YES

C. SCOTTAFB 17DCCI

BLDG/DIRECTIONS/ADDRESS: 1575; 103 WEST LOSEY STREET; SCOTT AFB,

IL 62225

RM/FL: C-1B; 1 FL

CONTACT: (PRI) CIRCUIT ACTIONS;

(EMAIL) 375CS.SCBTCA@US.AF.MIL; (C) 618-256-5090; (D) 57

6-5090

(ALT) TCF CIRCUIT ACTIONS;

(EMAIL) 375CS.SCOIT.NSC@US.AF.MIL; (C) 618-256-5030; (D)

576-5030

MAIL ADDRESS: BLDG 1575, ROOM C1B, 103 WEST LOSEY STREET, SCOTT

AFB, IL 62225-5431

DEMARK: BLDG 1575, ROOM C1B, 103 WEST LOSEY STREET, SCOTT AFB, IL

62225-5431

(PRI) CIRCUIT ACTIONS;

(EMAIL) 375CS.SCBTCA@US.AF.MIL; (C) 618-256-5090; (D) 576

-5090

NPA/NNX: 618/256

UNIT ID: USAF/AMC

(1) (A) N/A COMMERCIAL FACILITIES N/A; EQUIPMENT INFORMATION:

COMMERCIAL FIBER POINT OF PRESENCE

(B) UNIQUE INST FACT:

(1) FIBER CABLE X-CONNECT, IN-HOUSE, INSIDE WIRE, SINGLE-MODE, 1310NM, TELCO

(2) TELCO MULTIPLEX (COMMERCIAL FIBER POINT OF PRESENCE) COMMERCIAL CARRIER SYSTEM (LOCAL EXCHANGE CARRIER) PORT: BY LOCAL CARRIER

AMPLIFYING INFO:

A. VENDOR IS RESPONSIBLE FOR INSTALLATION AND MAINTENANCE OF THE SERVICE FROM THE LINE SIDE OF THE DISA IE1 PROVIDED FIBER TERMINATING PATCH PANEL INSTALLED IN THE CISCO ASR-9010 ROUTER SUITE (UJEWSCO030) BLDG 1575, ROOM C1B TO THE DROP SIDE OF THE COMMERCIAL FIBER POINT OF PRESENCE FIBER DISTRIBUTION PANEL BLDG 1575, ROOM C1B USING SINGLE MODE FIBER. COORDINATE TYPE CONNECTORS TO BE USED FOR TERMINATION TO THE DISA PROVIDED PATCH PANEL.

B. VENDOR MUST COORDINATE WITH GOVERNMENT SITE PERSONNEL TO CONDUCT WALK THROUGH SITE SURVEYS FOR EXACT CABLE FT. FROM THE DISA PROVIDED FIBER TERMINATING PATCH PANEL INSTALLED IN THE CISCO ASR-9010 ROUTER SUITE BLDG 1575, ROOM C1B TO THE COMMERCIAL FIBER POINT OF PRESENCE BLDG 1575, ROOM C1B.

C. VENDOR MUST PROVIDE FIBER STRANDS FROM THE DISA PROVIDED FIBER PATCH PANEL INSTALLED IN THE CISCO ASR-9010 ROUTER TO THE COMMERCIAL DEMARC LOCATION WITHOUT SPLICING AND OR USE OF CONNECTORS TO CONNECT 2 OR MORE FIBER STRANDS MEANING THE FIBER CANNOT BE BROKEN IN THE MIDDLE AND MUST BE CONTINUOUS.

D. VENDOR MUST SCHEDULE/COORDINATE WITH THE POC'S LISTED ON THIS ORDER 72 HOURS IN ADVANCE PRIOR TO SITE SURVEYS OR INSTALLATIONS.

(C) INSIDE WIRE INSTL/MAINT: CPIWI-YES/CPIWM-YES

9. TELECOMM PROVIDER MUST PROVIDE TOTAL FIBER MILES AND ROUND TRIP DELAY (RTD) FROM THE CUSTOMER "A" LOCATION TO THE CUSTOMER "Z" LOCATION.

10. THIS REQUIREMENT MUST BE ENGINEERED AND PROVISIONED TOTALLY DIVERSE END TO END TO THE GOVERNMENT'S SERVICE DELIVERY POINTS (SDP'S) FROM TSR SF30NOV179012; MEANING THAT THE PHYSICAL PATHS ARE TOTALLY SEPARATE INCLUDING MAN HOLES, CONDUIT, (CENTRAL OFFICE LOCATIONS), AND FIBER BUILDS. ADDITIONALLY, AS A MINIMUM MUST HAVE 50 METERS PHYSICAL SEPARATION FROM TSR SF30NOV179012.

11. VENDOR MUST PROVIDE LIGHT LEVEL READINGS (DB LOSS) ON EXTENSION FROM COMMERCIAL POP TO GOVERNMENT SERVICE DELIVERY POINT (SDP) AT THE "Z" LOCATION PRIOR TO CIRCUIT TURN UP TO K. REMARKS CONTINUED: MINIMUM TECHNICAL SPECIFICATIONS: SPECIFIC FORMAT TO BE USED IS: LINE RATE: 10.709 GIGABITS/S, +- 100 PPM LINE CODE: OPTIC ETHERNET FRAME: 9192 OCTETS (BYTES)

1. TEST AND ACCEPTANCE: 10GB LAN PHY CIRCUITS SHALL PASS A FULLY DOCUMENTED SATISFACTORY 72 HOUR SOAK TEST BY DISA GOC AT SCOTT AFB, IL. PRIMARY: (C) 618-229-8691 (D) 779-8691

2. TESTING PARAMETERS AND THRESHOLDS: THE FOLLOWING TESTING PARAMETERS SHALL BE MEASURED DURING TEST AND ACCEPTANCE TESTING. ERROR PERFORMANCE SHALL BE MEASURED AND RECORDED OVER THE DURATION OF THE CONTIGUOUS 24 HOUR TESTING INTERVAL AND SHALL BE MEASURED AND RECORDED PER DEFINITION IN ITU-T-Y.1564.

3. ERROR PERFORMANCE: ERROR PERFORMANCE SHALL BE BETTER THAN THE FOLLOWING PARAMETER THRESHOLDS TO BE ACCEPTABLE: AVAILABILITY SHALL BE GREATER THAN 99.5% OR BETTER. FRAME LOSS SHALL BE EQUAL TO ZERO WHEN TESTING AT 10 GIGABIT HIGHEST FRAME RATE, AND SHALL MEET ITU-T-Y.1564 STANDARDS. JITTER SHALL BE LESS THAN 3 MSEC. DELAY SHALL BE BETTER THAN 10 MSEC

4. MEAN TIME TO LOSS OF BIT COUNT INTEGRITY (MTTLBCI) SHALL BE GREATER THAN 24 HOURS.

5. ROUND TRIP DELAY (RTD): RTD SHALL BE MEASURED OVER THE 10GB WAVE CIRCUIT AND SHALL BE LESS THAN OR EQUAL TO 10 MILLISECONDS.

12. VENDOR MUST CONDUCT WALK-THROUGH SITE SURVEY PRIOR TO INSTALLATION AT THE "Z" LOCATION ONLY.

14. PROVIDER MUST CONDUCT A SATISFACTORY 24-HOUR TEST FROM THE DROP SIDE OF THEIR OR LOCAL EXCHANGE CARRIERS FDP INSTALLED IN THEIR EQUIPMENT SUITE AT THE "A" LOCATION TO THE GOVERNMENT'S SDP AT THE "Z" LOCATION AND MUST INCLUDE THE EXTENSION BETWEEN THE COMMERCIAL DEMARC AND THE GOVERNMENT'S SDP AT THE "Z" LOCATION. VENDOR MUST ENSURE A TEST SET IS PLACED AT THE DROP SIDE OF TELECOMM PROVIDER'S OR LOCAL ACCESS PROVIDERS FDP AS APPLICABLE AT THE "A" LOCATION AND A SECOND TEST SET AT THE END OF THE FIBER JUMPERS TO BE USED FOR TERMINATION TO THE GOVERNMENT'S SDP AT THE "Z" LOCATION. TESTING MUST BE SATISFACTORY PRIOR TO TURN OVER TO THE GOVERNMENT FOR ACCEPTANCE TESTING. TESTING CRITERIA: VENDOR MUST TEST THE CIRCUIT FOR 24 HOURS IAW ITU-T.Y.1564 BENCH MARKING CONFIGURATION AND PERFORMANCE OF ETHERNET SERVICE. NOTE-ETHERNET FRAME SIZE DESIGNATOR 'H' (MTU) IS EQUAL TO 9192 BYTES.

1. CIRCUIT REQUIRES THE FOLLOWING PARAMETERS:

(A) FIBER TERMINATION: FRAME FORMAT: 10GB ETHERNET (OPTICAL HANDOFF-10GB ETHERNET-LAN-PHY-SINGLE MODE FIBER), 802.3AE, 1310NM. "SC" CONNECTORS.

(B) COMMITTED INFORMATION RATE (CIR) - 10GB.

(C) 10GB ETHERNET - LAN-PHY INTERFACE REQUIRED AT COMMERCIAL DEMARC AT THE A AND Z LOCATIONS.

(D) ETHERNET FRAME SIZE WILL BE CONFIGURED TO SUPPORT MAXIMUM TRANSMISSION UNIT (MTU) OF 9192 OCTETS (BYTES).

(E) NO NETWORK INTERFACE UNIT, DEDICATED PATH

(F) GFE CLOCKING: VENDOR ESFU (OR EQUIVALENT) NOT TO BE ENGINEERED INTO CIRCUIT.

(G) TESTING CRITERIA: VENDOR MUST TEST THE CIRCUIT FOR 24 HOURS IAW ITU-T.Y.1564 BENCH MARKING CONFIGURATION AND PERFORMANCE OF ETHERNET SERVICE. NOTE-ETHERNET FRAME SIZE DESIGNATOR 'H' (MTU) IS EQUAL TO 9192 BYTES.

(H) LINE MUST REMAIN FULLY OPERATIONAL AND AVAILABLE TO USERS 24 HOURS A DAY, SEVEN DAYS PER WEEK, AT LEAST 99.5% OR BETTER.

(I) 1 HOUR RESPONSE TIME TO RESPOND TO CUSTOMER UPON RECIEPT OF TROUBLE.

(J) VENDOR REQUIRED TO HAVE CIRCUIT VISIBILITY TO ASSIST IN ANY CIRCUIT OUTAGES.

(K) VENDOR MUST HAVE A 24X7 NETWORK OPERATIONS CENTER.

(L) TELECOMM PROVIDER MUST MAINTAIN OPERATIONS, MAINTENANCE AND ADMINISTRATION MONITORING OF ETHERNET CIRCUIT IAW ITU-T-Y.1731.

(N) VENDOR MUST PROVIDE:

1. THE LONG-HAUL CIRCUIT NO. AND LEC CKT ID'S AS APPLICABLE TO THE DISA IE161 PROGRAM OFFICE PRIOR TO TURN UP TO THE GOVERNMENT.

2. VENDOR WINNING AWARD IS RESPONSIBLE FOR INSTALLATION AND MAINTENANCE OF 10GBE SERVICE IAW THE UNIQUE INSTALLATION FACTORS.

3. INSIDE WIRING IS AUTHORIZED IAW THE UNIQUE INSTALLATION FACTORS.

4. VENDOR MUST COORDINATE SITE VISIT WITH POC'S 72 HOURS IN ADVANCE PRIOR TO REQUIRING ACCESS TO FACILITIES AT BOTH USER LOCATIONS.

Q. FACILITY SECURITY ACCESS REQUIREMENT: (SP A) CLEARANCE REQUIRED; ESCORT REQUIRED;

File details come from the government source that posted it.