Text version
Circuit Parameters and Testing Requirements for Solicitation HC101318QA868
TEST & ACCEPTANCE INSTRUCTIONS: CONUS ETHERNET
VENDOR WILL PERFORM ACCEPTANCE TESTING IN ACCORDANCE WITH EITHER
RFC-6815 OR ITU-T Y.1564. SPECIFICALLY, FRAME SIZES OF
64,128,256,512,1024,1280 AND 1518 BYTES MUST BE USED. THE
TEST MUST VERIFY LENGTH OF RECEIVED FRAMES, INDICATE NUMBER
OF FRAMES DROPPED, NUMBER OF FRAMES RECEIVED OUT OF ORDER,
AND DUPLICATE FRAMES. TESTS MUST BE BI-DIRECTIONAL USING THE
SAME DATA RATE IN EACH DIRECTION. BURST TESTS MUST BE RUN TO
DETERMINE MINIMUM INTERVAL BETWEEN FRAMES THAT CAN BE
PROCESSED WITHOUT FRAME LOSS.
A THROUGHPUT TEST IS REQUIRED INDICATING THE FASTEST RATE AT
WHICH TEST FRAMES CAN BE TRANSMITTED WITHOUT FRAME LOSS. A
SEPARATE THROUGHPUT TEST MUST BE RUN WITH FRAMES ADDRESSED TO
THE HARDWARE BROADCAST ADDRESS CONSTITUTING AT LEAST 1% OF
THE TEST STREAM AND BE EVENLY DISTRIBUTED THROUGHOUT THE
TEST. A LATENCY TEST MUST BE RUN FOR A PERIOD OF NO LESS THAN
120 SECONDS, AND REPEATED NO LESS THAT 20 TIMES. THE TEST STREAM
FOR THE LATENCY TEST SHOULD BE RUN AT THE THROUGHPUT RATE FOR
CORRESPONDING FRAME SIZES FROM THE THROUGHPUT TEST.
END TO END LATENCY WILL BE CALCULATED AS THE AVERAGE OVER THE
20 TEST RUNS. FRAME LOSS RATE TESTS SHOULD BE RUN AT THE FRAME
RATE CORRESPONDING TO THE MAXIMUM FRAME RATE, AND REDUCED BY
10% INTERVALS UNTIL THERE ARE AT LEAST TWO CONSECUTIVE RUNS IN
WHICH NO FRAMES ARE LOST.
THROUGHPUT TEST RESULTS:
PASSING RATE 100% FOR ALL FRAME BYTE
SIZES EXERCISED. FRAME LOSS RATE (%) RESULTS: FRAME LOSS RATE
LESS THAN 0.01% FOR ALL FRAME BYTE SIZES EXERCISED.
LATENCY WILL BE MEASURED WILL BE ACCORDING TO THE FOLLOWING
MAXIMUM TRANSMISSION DELAY FOR ANY CIRCUIT UP TO 500 MILES
AIR-MILES IN LENGTH SHALL BE NO GREATER THAN 13MS ONE-WAY AND
ANY POINT-TO-POINT CIRCUIT LONGER THAN 500 AIR-MILES SHALL
BE NO GREATER THAN 50MS ONE WAY WITHIN THE 48 CONTINENTAL
STATES. ANY APS SWITCHOVER SHALL TAKE LESS THAN 50 MILLISECONDS.
A. ANY ADDRESSEE ON THE TSO WILL NOTIFY ALL
ADDRESSEES IMMEDIATELY BY MESSAGE IDENTIFYING ANY ISSUES,
PROBLEMS, OR SITUATIONS WHICH MAY PREVENT OR DELAY THE
IMPLEMENTATION OF THIS TELECOMMUNICATIONS SERVICE ORDER (TSO).
ALL STATIONS WILL REVIEW THE CONFIGURATION, EQUIPMENT, CONTACT
NUMBERS AND ADDRESSES CONTAINED IN THIS TSO AND PROVIDE UPDATES
TO ORIGINATOR OF TSO ANY ERRORS SO THAT SUBSEQUENT TSOS MAY BE
UPDATED.
B. COMPLETION REPORT: FOR STATION DESIGNATED IN PARAGRAPH 2H AS
CCO/CMO, FOR THIS ACTION COMPLETION REPORTS WILL BE SUBMITTED IAW
DISAC 310-130-1, CHAPTER 2 BY DISA GLOBAL IP, DSN 312-770-8627;
COML 618-220-8627. ALL OTHER CCO/CMO RESPONSIBILITIES REMAIN
WITH THE DESIGNATED CCO/CMO IAW DISAC 310-70-1, CHAPTER 8.
C. IMPLEMENTATION ASSISTANCE: FOR DISN CORE / DEDICATED / NIPRNET /
SIPRNET / VPN CIRCUIT ACTIVATION ASSISTANCE OR SERVICE IMPLEMENTA
TION INQUIRIES/SCHEDULING, CONTACT THE DISA GLOBAL RF ACTIVATIONS
TEAM VIA EMAIL, DISA.SCOTT.CONUS.MBX.RF-CIRCUIT-ACTIVATIONS@MAIL
.MIL, OR CALL DSN 770-8627; COML 618-220-8627.
D. IMPLEMENTATION ASSISTANCE CONTINUED: FOR CIRCUIT INSTALLATION
ASSISTANCE WITH THE COMMERCIAL LEASED PATH, CONTACT
DCP COMMERICIAL ACTIVATION TEAM (CAT) AT D312-850-0820,
C614-692-0820
E. DD FORM 1368: DD FORM 1368'S (MODIFIED USE OF LEASED
COMMUNICATION FACILITIES), OR EMAIL EQUIVALENT, WILL BE
SUBMITTED, AS REQUIRED, ON THIS CIRCUIT IAW DISAC-DITCO 350-135-1
BY THE STATION DESIGNATED IN PARAGRAPH 2H AS CCO/CMO. GUIDANCE
ON SUBMISSION IS AVAILABLE AT
HTTP://WWW.DITCO.DISA.MIL/CORPORATELIBRARY/HOME.ASP. CLICK ON
"350-135-1, DEFENSE COMMERCIAL COMMUNICATIONS ACQUISITION
PROCEDURES."
F. CONNECTION APPROVAL PROCESS STATEMENT: FOR IP CUSTOMER/USER: IAW
CJCSI 6211.02C AND DISA DIRECTIVES **FAILURE TO REGISTER AND
OBTAIN DISA CONNECTION APPROVAL (IATC/ATC) FOR YOUR CIRCUIT WILL
RESULT IN DELAY OF CIRCUIT ACTIVATION**
CONNECTIVITY TO THE SIPRNET, NIPRNET AND VPN MUST COMPLY
WITH THE SECURITY ACCREDITATION REQUIREMENTS SPECIFIED IN THE
CONNECTION PROCESS GUIDE (CPG) AND CURRENT DOD POLICY. THE CPG
CAN BE VIEWED AT THE FOLLOWING URL: HTTP://WWW.DISA.MIL/CONNECT.
IT IS THE RESPONSIBILITY OF THE CUSTOMER TO ENSURE THAT ALL
NEW, REHOMED, AND UPGRADED IP CIRCUITS ARE REGISTERED. THE
IATC/ATC LETTERS MUST BE OBTAINED THROUGH THE UNCLASIFIED
CONNECTION APPROVAL OFFICE (UCAO) OR CLASIFIED CONNECTION
APPROVAL OFFICE (CCAO) BEFORE CIRCUIT ACTIVATION.
FOR ALL REGISTERED CIRCUITS, THE REGISTRATION MUST BE
UPDATED TO REFLECT CURRENT ACCREDITATION INFORMATION AND A COPY
OF THE ACCREDITATION DECISION, CONSENT TO MONITOR, AND ENCLAVE
TOPOLOGY MUST BE SUBMITTED TO THE UCAO (NIPR) OR CCAO (SIPR).
THE CCSD AND TRACKING NUMBER ARE REQUIRED TO UPDATE AN EXISTING
RECORD.
FOR A DETAILED DESCRIPTION OF THE DISN CONNECTION PROCESS
VISIT HTTP://WWW.DISA.MIL/CONNECT. IF YOU ARE UNABLE TO ACCESS
THE WEBSITE OR REQUIRE SPECIFIC GUIDANCE FOR UNIQUE CUSTOMER
ISSUES, PLEASE CONTACT THE CONNECTION APPROVAL OFFICE (CAO) AT
CMCL: 301-225-2900/1, DSN 312-375-2900/1
G. UNSATISFACTORY SERVICE REPORTING INSTRUCTIONS: FOR UNSATISFACTORY
SERVICE OR TO REPORT EQUIPMENT AND/OR CIRCUIT PROBLEMS INVOLVING
DISA PROVIDED TRANSPORT AND/OR EQUIPMENT, PLEASE CONTACT THE
DISN CUSTOMER CONTACT CENTER (DCCC) TOLL FREE NUMBER IS
1-844-347-2457 (1-844-DISA HLP) OPTION 2, COML 1-614-692-0032
OPTION 2, DSN 312-850-0032 OPTION 2.
File details come from the government source that posted it.