AMPLIFYING INFO:

A. DISA IE4 IS RESPONSIBLE FOR INSTALLATION AND GSM-O FOR MAINTENANCE OF THE CISCO ASR-9010 ROUTER, OPTICAL INTERFACE CARD BLDG 6434-4, ROOM 4-1-20.

B. DISA IE4 IS RESPONSIBLE FOR INSTALLATION AND GSM-O OF SINGLE MODE FIBER FROM THE OPTICAL INTERFACE CARD INSTALLED IN THE CISCO ASR-9010 ROUTER TO THE DROP SIDE OF THE DISA IE1 PROVIDED FIBER TERMINATING PATCH PANEL INSTALLED IN THE CISCO ASR-9010 SUITE. TYPE CONNECTORS TBD.

C. VENDOR IS RESPONSIBLE FOR INSTALLATION AND MAINTENANCE SINGLE MODE FIBER FROM THE LINE SIDE OF THE DISA PROVIDED FIBER TERMINATING PATCH PANEL INSTALLED IN THE CISCO ASR-9010 ROUTER SUITE (UJEWKNO040) BLDG 6434-4, ROOM 4-1-20 TO THE DROP SIDE OF THE COMMERCIAL FIBER POINT OF PRESENCE FIBER DISTRIBUTION PANEL BLDG 6434-4, ROOM 4-1-MO3. COORDINATE TYPE OF CONNECTORS FOR TERMINATION TO THE DISA PROVIDED PATCH PANEL.

D. THE LENGTH OF SINGLE MODE FIBER JUMPERS REQUIRED WILL BE BASED ON THE LOCATION OF THE VENDOR'S FIBER MUX/FIBER DISTRIBUTION PANEL.

E. THE CIRCUIT MUST BE TAGGED WITH THE LOCAL CIRCUIT ID AND LONG HAUL CIRCUIT NO. AT THE LINE SIDE OF THE DISA PROVIDED FIBER TERMINATING PATCH PANEL BLDG 6434-4, ROOM 4-1-20 AND AT THE DROP SIDE OF THE VENDOR'S FIBER DISTRIBUTION PANEL INSTALLED IN THEIR SONET EQUIPMENT SUITE. ADDITIONALLY, VENDOR MUST SHOW SITE PERSONNEL LISTED ON THIS ORDER THE EXACT TERMINATION POINT WHEN SERVICE IS COMPLETE.

AMPLIFYING INFO:

A. VENDOR IS RESPONSIBLE FOR INSTALLATION AND MAINTENANCE OF SINGLE MODE FIBER FROM THE COMMERCIAL FIBER POINT OF PRESENCE FIBER DISTRIBUTION PANEL BLDG 271, ROOM 128, TO LINE SIDE OF THE DISA IE1 PROVIDED FIBER TERMINATING PATCH PANEL INSTALLED IN THE CISCO ASR-9010 ROUTER SUITE (UJEWWPA030) BLDG 271, ROOM 128. COORDINATE TYPE CONNECTORS FOR TERMINATION TO THE DISA PROVIDED PATCH PANEL.

B. THE CIRCUIT MUST BE TAGGED WITH THE LOCAL CIRCUIT ID AND LONG HAUL CIRCUIT NO. AT THE DROP SIDE OF THE VENDOR'S FIBER DISTRIBUTION PANEL INSTALLED IN THEIR SONET EQUIPMENTSUITE AND AT THE LINE SIDE OF THE DISA PROVIDED FIBER TERMINATING PATCH PANEL BLDG 271, ROOM 128. ADDITIONALLY, VENDOR MUST SHOW SITE PERSONNEL LISTED ON THIS ORDER THE EXACT TERMINATION POINT WHEN SERVICE IS COMPLETE.

6. ***ATTENTION WHITE SANDS LOCATION***

THIS REQUIREMENT MUST BE ENGINEERED AND PROVISIONED TOTALLY DIVERSE END TO END TO THE GOVERNMENT'S SERVICE DELIVERY POINTS (SDP'S) FROM TSR SF29JAN189416; MEANING THAT THE PHYSICAL PATHS ARE TOTALLY SEPARATE INCLUDING MAN HOLES, CONDUIT, (CENTRAL OFFICE LOCATIONS), AND FIBER BUILDS. ADDITIONALLY AS A MINIMUM MUST HAVE 50 METERS PHYSICAL SEPARATION FROM TSR SF29JAN189416.

7. TELECOMM PROVIDER MUST PROVIDE DISA COLOR POWERPOINT DRAWINGS FOR TECHNICAL REVIEW SHOWING THE ROUTES FROM THE COMMERCIAL DEMARCS TO THE SUPPORTING CENTRAL OFFICES AND OR WIRING CENTERS ENSURING THE PHYSICAL END TO END DIVERSITY REQUIREMENTS ARE BEING MET. DRAWINGS ALSO TO INCLUDE SEPARATION DISTANCES, TOTAL FIBER MILES AND ROUND TRIP DELAY (RTD). ADDITIONALLY MUST PROVIDE COLOR CODED MAPS AND MUST BE RED LINED SHOWING HOW THE CIRCIT WILL BE ROUTED END TO END FROM THE CUSTOMER A LOCATON TO THE CUSTOMER Z LOCATION.

1. CIRCUIT REQUIRES THE FOLLOWING PARAMETERS:

(A) FIBER TERMINATION: FRAME FORMAT: STS-48C, 1310NM RATE: PLUS OR MINUS 20 PPM USER PROVIDED STS-48C FRAMING FROM GOVT CISCO ROUTER.

(B) NO CHANNELIZATION REQUIRED.

(C) LINE MUST REMAIN FULLY OPERATIONAL AND AVAILABLE TO USERS 24 HOURS A DAY, SEVEN DAYS PER WEEK, AT LEAST 99.5% OR BETTER.

(D) REQUEST ONE-HOUR RESPONSE TIME TURN-AROUND TO REPAIR ONCE TROUBLE-CALL HAS BEEN REPORTED.

(E) GFE CLOCKING: VENDOR ESFU (OR EQUIVALENT) NOT TO BE ENGINEERED INTO CIRCUIT.

M. REMARKS CONTINUED: (F) SINGLE MODE FIBER TERMINATIONS SC/SC CONNECTORS

(G) NO NETWORK INTERFACE UNIT.

(H) DEDICATED PATH.

(I) VENDOR REQUIRED TO HAVE CIRCUIT VISIBILITY TO ASSIST IN ANY CIRCUIT OUTAGES.

(J) VENDOR MUST TEST THE CIRCUIT END TO END FOR 72 HOURS UTILIZING A 2E23 TEST PATTERN.

(K) VENDOR MUST HAVE A 24X7 NETWORK OPERATIONS CENTER.

(L) THE COMMERCIAL CIRCUIT WILL BE ACCEPTED ON BEHALF OF THE GOVERNMENT BY THE CONUS IP BACKBONE ENGINEERING AND IMPLEMENTATION GROUP, SCOTT AFB, IL.

(M) VENDOR MUST PROVIDE:

1.) THE LONG HAUL CIRCUIT NO. AND LEC CKT ID. PRIOR TO TURN UP TO THE GOVERNMENT.

2. VENDOR WINNING AWARD IS RESPONSIBLE FOR INSTALLATION AND MAINTENANCE OF OC-48C SERVICE IAW THE UNIQUE INSTALLATION FACTORS.

3. INSIDE WIRING IS AUTHORIZED IAW WITH THE UNIQUE INSTALLATION FACTORS.

4. VENDOR MUST COORDINATE SITE VISIT WITH POC'S 72 HOURS IN ADVANCE PRIOR TO REQUIRING ACCESS TO FACILITIES AT BOTH USER LOCATIONS. IF UNABLE TO REACH SITE POC'S CONTACT KEN DIEF OR RAY BURKE IMMEDIATELY FOR ASSISTANCE AT: (301) 225-2416/2550

5. ALL EQUIPMENT AND CIRCUIT PROBLEMS WILL BE REPORTED BY PHONE TO THE CONUS IP BACKBONE ENGINEERING AND IMPLEMENTATION GROUP, SCOTT AFB, IL.PRIMARY: (C) 618-220-9950(D) 770-9950 TOLL FREE: 855-868-9950

6. DD FORM 1368 WILL BE SUBMITTED ON THIS TRUNK IAW DISAC-DITCO 350-135-1 BY RNSOC, SCOTT AFB, IL. GUIDANCE ON SUBMISSION IS AVAILABLE<HTTP://WWW.DITCO.DISA.MIL/ASP/PUBLICATIONS.ASP>. CLICK ON "DISA-DITCO CIRCULAR, 350-135-1, DEFENSE COMMERCIAL COMMUNICATIONS ACQUISITION PROCEDURES."

MINIMUM TECHNICAL SPECIFICATIONS:

SPECIFIC FORMAT TO BE USED IS: LINE RATE: OC-48C/ 20 PPM. LINE CODE: OPTIC FRAME FORMAT: SONET/STS-48C N. TEST & ACCEPTANCE INSTRUCTIONS: 1. TEST AND ACCEPTANCE: FIBER OPTIC OC-48C CIRCUITS SHALL PASS A FULLY DOCUMENTED SATISFACTORY 72 HOUR SOAK TEST BY THE CONUS AT SCOTT AFB.

2. TESTING PARAMETERS AND THRESHOLDS: THE FOLLOWING TESTING PARAMETERS SHALL BE MEASURED DURING TEST AND ACCEPTANCE TESTING. ERROR PERFORMANCE (AVAILABILITY, SES, DM, EFS) AND LOSS OF BIT COUNT INTEGRITY SHALL BE MEASURED AND RECORDED OVER THE DURATION OF THE CONTIGUOUS 72 HOUR TESTING INTERVAL AND SHALL BE MEASURED AND RECORDED PER DEFINITION IN ITU RECOMMENDATION G.826 AND M.2100.

3. ERROR PERFORMANCE:

ERROR PERFORMANCE SHALL BE BETTER THAN THE FOLLOWING PARAMETER THRESHOLDS TO BE ACCEPTABLE: AVAILABILITY SHALL BE GREATER THAN 99.5% OR BETTER SEVERELY ERRORED SECONDS (SES) SHALL BE LESS THAN 0.02% DEGRADED MINUTES (DM) SHALL BE LESS THAN 0.2% ERROR FREE SECONDS (EFS) SHALL BE GREATER THAN 99%

4. LOSS OF BIT COUNT INTEGRITY (LBCI): LOSS OF BIT COUNT INTEGRITY SHALL BE MONITORED ONLY BY THE FOLLOWING METHOD: USING TEST EQUIPMENT WHICH CAN DETECT AND MEASURE THE OCCURRENCE OF THE INSERTION OR DELETION OF ONE OR MORE BITS INTO THE DIGITAL BIT STREAM, ON MANY MANUFACTURERS BERT TEST EQUIPMENT THIS IS MONITORED USING THE "PATTERN SLIP" PARAMETER WHERE EVERY OCCURRENCE OF A PATTERN SLIP "EVENT" MARKS THE OCCURRENCE OF A LBCI (RATHER THAN THE RAW TOTAL NUMBER OF PATTERN SLIPS ACCUMULATED OVER A TESTING INTERVAL)

5. MEAN TIME TO LOSS OF BIT COUNT INTEGRITY (MTTLBCI) SHALL BE GREATER THAN 24 HOURS.

6. ROUND TRIP DELAY (RTD): RTD SHALL BE MEASURED OVER THE OC-48C CIRCUIT AND SHALL BE LESS THAN OR EQUAL TO (10) MILLISECONDS.

(** DIVERSITY INFO **)

SERVICE DIVERSITY REQUESTED; DUAL HOMING CCSD: BEW0

(** ADDITIONAL PROVISIONING INFORMATION **) (ORG ACCT) DISA (DISN IP ROUTER NETWORK BACKBONE AND BACKBONE HOSTS)(CONUS AND OCONUS) O. COMPLETION REPORT: STATION DESIGNATED IN PARAGRAPH 2H AS CCO/CMO WILL SUBMIT COMPLETION REPORT IAW DISAC 310-130-1, SUPP 1, 2, 3 FORMAT OR DISAC 310-70-1. REPORT WILL BE ADDRESSED TO ORIGINATOR AND ALL ADDRESSEES OF THIS TSO.

P. IMPLEMENTATION ASSISTANCE: FOR DISN CORE / DEDICATED / NIPRNET / SIPRNET / VPN CIRCUIT ACTIVATION ASSISTANCE OR SERVICE IMPLEMENTATION INQUIRIES/SCHEDULING, CONTACT THE DISA GLOBAL RF ACTIVATIONSTEAM VIA EMAIL, DISA.SCOTT.CONUS.MBX.RF-CIRCUIT-ACTIVATIONS@MAIL.MIL, OR CALL DSN 770-8627; COML 618-220-8627.

Q. UNSATISFACTORY SERVICE REPORTING INSTRUCTIONS: FOR UNSATISFACTORY SERVICE OR TO REPORT EQUIPMENT AND/OR CIRCUIT PROBLEMS INVOLVING DISA PROVIDED TRANSPORT AND/OR EQUIPMENT, PLEASE CONTACT THE DISN CUSTOMER CONTACT CENTER (DCCC) SCOTT AFB, IL, TOLL FREE NUMBER IS 1-844-347-2457 (1-844-DISA HLP) OPTION 2, COML 1-614-692-0032 OPTION 2, DSN 312-850-0032 OPTION 2.

R. DD FORM 1368: DD FORM 1368'S (MODIFIED USE OF LEASED COMMUNICATION FACILITIES), OR EMAIL EQUIVALENT, WILL BE SUBMITTED, AS REQUIRED, ON THIS CIRCUIT IAW DISAC-DITCO 350-135-1 BY THE STATION DESIGNATED IN PARAGRAPH 2H AS CCO/CMO. GUIDANCE ON SUBMISSION IS AVAILABLE AT HTTP://WWW.DITCO.DISA.MIL/CORPORATELIBRARY/HOME.ASP. CLICK ON "350-135-1, DEFENSE COMMERCIAL COMMUNICATIONS ACQUISITION PROCEDURES."

S. REMARKS CONTINUED: OPERATIONAL SERVICE DATE: 310800Z JUL 18

T. THIS TSO IS IN SUPPORT OF EXERCISE/PROJECT: DISA MPLS IMPLEMENTATION PROJECT

U. SATELLITE OBJECTION: DIVERSITY: ...;

V. REMARKS CONTINUED: FUNDING TCO APL: (** ON BEHALF OF **) DEFENSE INFORMATION SYSTEMS AGENCY (DISA); (** FUNDING APPROVAL **) REFERENCE: A. DISAC310-130-1 B. CHRIS MEDLEY (ISC) DIRECTION / 19 JAN 18 W. JUSTIFICATION OF SERVICE REQUESTED: THIS REQUIREMENT IS A BONA FIDE NEED OF FY18 ANDDISA FY18 FUNDING INFORMATION IS AVAILABLE IN DISA'S TELECOMMUNICATIONS INVENTORY AND BILLING INFORMATION (TIBI) APPLICATION.INFORMATION (TIBI) APPLICATION.

X. TSO CONTACT: DISA PROVISIONING POC IS ANDREW LASTIVKA, DSN 312-85 0-0882, CML 614-692-0882, E-MAIL ANDREW.T.LASTIVKA.CTR@MAIL.MIL, MAILING ADDRESS: DISA COLUMBUS, P.O. BOX 3990 COLUMBUS, OH 43218-3990