Location A, LOCATION OF TERMINATION A change from:
ADDRESS: (BLDG) 291; 80 TRUMAN AVENUENAS/TRUMAN ANNEX; KEY WEST, FL, 33040
ROOM: 210-B; 1 FL
LOCATION: TRMNANNX
To:
ADDRESS: (BLDG) 1279; 20 TRUMAN AVENUENAS/TRUMAN ANNEX; KEY WEST, FL, 33040
ROOM: 126; 1 FL
LOCATION: TRMNANNX
Location A, DEMARK change from:
(BLDG) 291; RM 210-B
80 TRUMAN AVENUE
NAS/TRUMAN ANNEX; KEY WEST, FL 33040
To:
(BLDG) 1279; RM 126
20 TRUMAN AVENUE
NAS/TRUMAN ANNEX; KEY WEST, FL 33040
Location A, UNIQUE INSTALLATION FACTORS change from:
(1) FIBER CABLE X-CONNECT, IN-HOUSE, INSIDE WIRE,
SINGLE-MODE, 1310NM, TELCO;
(2) COMMERCIAL FIBER POINT OF PRESENCE (COMMERCIAL CARRIER
SYSTEM);
AMPLIFYING INFO:;
A. VENDOR IS RESPONSIBLE FOR INSTALLATION AND MAINTENANCE
OF SINGLE MODE FIBER FROM THE LINE SIDE OF THE DISA
IE1 PROVIDED FIBER TERMINATING PATCH PANEL INSTALLED
IN THE MSPP SUITE (UMSWTRN010) BLDG 291, ROOM 210-B
TO THE DROP SIDE OF THE COMMERCIAL FIBER POINT OF
PRESENCE FIBER DISTRIBUTION PANEL (FDP) BLDG 291, ROOM
210-B. TERMINATE WITH "SC" CONNECTORS FROM DISA
PROVIDED FIBER TERMINATING PATCH PANEL.;
B. VENDOR MUST PROVIDE FIBER STRANDS FROM THE MSPP SUITE
LOCATION TO THE COMMERCIAL DEMARC WITHOUT SPLICING AND
OR USE OF CONNECTORS TO CONNECT 2 OR MORE FIBER STRANDS
MEANING THE FIBER CANNOT BE BROKEN IN THE MIDDLE MUST
BE CONTINUOUS.;
C. THE CIRCUIT MUST BE TAGGED WITH THE LOCAL CIRCUIT ID
AND LONG HAUL CIRCUIT NO. AT THE DROP SIDE OF THE
COMMERCIAL DEMARC LOCATION BLDG 291, ROOM 210-B.
ADDITIONALLY, VENDOR MUST SHOW SITE PERSONNEL LISTED
ON THIS ORDER THE EXACT TERMINATION POINTS WHEN
INSTALLATION IS COMPLETE.;
D. VENDOR MUST SCHEDULE/COORDINATE WITH THE POC'S LISTED
ON THIS ORDER 72 HOURS IN ADVANCE PRIOR TO SITE
SURVEYS OR INSTALLATIONS.
(1) FIBER CABLE X-CONNECT, IN-HOUSE, INSIDE WIRE,
SINGLE-MODE, 1310NM, TELCO;
(2) COMMERCIAL FIBER POINT OF PRESENCE
(3) FIBER CABLE X-CONNECT, IN-HOUSE, INSIDE WIRE,
SINGLE-MODE, 1310NM, TELCO;
(4) COMMERCIAL FIBER POINT OF PRESENCE;
AMPLIFYING INFO:;
A. JIATFS J6 PERSONNEL ARE RESPONSIBLE FOR INSTALLATION
AND MAINTENANCE OF SINGLE MODE FIBER FROM LINE SIDE
OF SITE PROVIDED FIBER TERMINATING PATCH PANEL BLDG
291, ROOM 210-B TO LINE SIDE OF SITE PROVIDED FIBER
TERMINATING PATCH PANEL BLDG 1279, ROOM 126.
B. VENDOR IS RESPONSIBLE FOR INSTALLATION AND
MAINTENANCE OF SINGLE MODE FIBER FROM DROP SIDE OF
SITE PROVIDED FIBER TERMINATING PATCH PANEL BLDG
1279, ROOM 126 TO DROP SIDE OF COMMERCIAL FIBER
POINT OF PRESENCE FIBER DISTRIBUTION PANEL BLDG
1279, ROOM 126. COORDINATE TYPE CONNECTORS FOR
TERMINATION TO SITE PROVIDED PATCH PANEL.
COORDINATE WITH SITE PERSONNEL FOR FIBER PAIR
ASSIGNMENTS TO SITE PROVIDED FIBER TERMINATING
PATCH PANEL IN BLDG 1279, ROOM 126 CORRESPONDING
TO FIBER TERMINATIONS TO SITE PROVIDED TERMINATING
PATCH PANEL IN BLDG 291.;
C. VENDOR MUST COORDINATE WITH GOVERNMENT SITE
PERSONNEL TO CONDUCT WALK THROUGH SITE SURVEY FOR
EXACT CABLE FT. FROM SITE PROVIDED FIBER
TERMINATING PATCH PANEL BLDG 1279, ROOM 126 TO THE
COMMERCIAL FIBER POINT OF PRESENCE BLDG 1279, ROOM 126.;
D. VENDOR MUST PROVIDE FIBER STRANDS FROM DISA
PROVIDED FIBER PATCH PANEL INSTALLED IN JUNIPER
ROUTER TO THE COMMERCIAL DEMARC LOCATION WITHOUT
SPLICING AND OR USE OF CONNECTORS TO CONNECT 2 OR
MORE FIBER STRANDS MEANING THE FIBER CANNOT BE
BROKEN IN THE MIDDLE AND MUST BE CONTINUOUS.;
E. CIRCUIT MUST BE TAGGED WITH LOCAL CIRCUIT ID AND
LONG HAUL CIRCUIT NO. AT DROP SIDE OF COMMERCIAL
DEMARC AND SITE PROVIDED FIBER PATCH PANEL BLDG
1279, ROOM 126. ADDITIONALLY, VENDOR MUST SHOW SITE
PERSONNEL LISTED ON THIS ORDER THE EXACT
TERMINATION POINT WHEN INSTALLATION IS COMPLETE.;
F. VENDOR MUST SCHEDULE/COORDINATE WITH POC'S
LISTED ON THIS ORDER 72 HOURS IN ADVANCE PRIOR TO SITE
SURVEYS OR INSTALLATIONS.
Location A, INTERFACE change from:
INTERFACE: SONET OC-12C; ELECTRICAL: OPTICAL; PHYSICAL: SNAPCLICK (SC); (PHYSICAL) SNAP CLICK (SC);
(ELECTRICAL) OPTICAL
To:
INTERFACE: SONET OC-12C; ELECTRICAL: OPTICAL; PHYSICAL: SNAP CLICK (SC); (PHYSICAL) SNAP CLICK (SC);
(ELECTRICAL) OPTICAL
Location A, TERMINAL EQUIPMENT change from:
EQUIPMENT INFORMATION: COMMERCIAL FIBER POINT OF PRESENCE
To:
EQUIPMENT INFORMATION: FIBER TERMINATING PATCH PANEL (GFE) (SITE PROVIDED) (TO B291); COMMERCIAL
FIBER POINT OF PRESENCE
Location B, LOCATION OF TERMINATION B change from:
ADDRESS: (BLDG) TERREMARK BLDG (NAP); 50 NE 9TH STREET; MIAMI, FL 33132
ROOM: 356; 3RD FL
LOCATION: MIAMINAP
ADDRESS: (BLDG) TERREMARK BLDG (NAP); 50 NE 9TH STREET; MIAMI, FL 33132
ROOM: Meet Point Room (MPR); 2 FL
LOCATION: MIAMINAP
Location B, DEMARK change from:
(BLDG) TERREMARK BLDG (NAP);
RM 356
50 NE 9TH STREET; MIAMI, FL 33132
To:
(BLDG) TERREMARK BLDG (NAP);
50 NE 9TH STREET; MIAMI, FL 33132
Location B, UNIQUE INSTALLATION FACTORS change from:
(1) COMMERCIAL FIBER POINT OF PRESENCE (COMMERCIAL
CARRIER SYSTEM);
(2) FIBER CABLE X-CONNECT, IN-HOUSE, INSIDE WIRE,
SINGLE-MODE, 1310NM, TELCO;
(3) FIBER TERMINATING PATCH PANEL (SITE PROVIDED)
(4) FIBER CABLE X-CONNECT, IN-HOUSE, INSIDE WIRE,
SINGLE-MODE, 1310NM, TERREMARK PERSONNEL;
AMPLIFYING INFO:;
A. VENDOR IS RESPONSIBLE FOR INSTALLATION AND MAINTENANCE
OF SINGLE MODE FIBER FROM THE DROP SIDE OF THE
COMMERCIAL FIBER POINT OF PRESENCE [FIBER DISTRIBUTION
PANEL (FDP)] TERREMARK BLDG, MEET POINT ROOM (MPR) TO
THE LINE SIDE OF THE SITE PROVIDED FIBER TERMINATING
PATCH PANEL TERREMARK BLDG, MEET POINT ROOM (MPR).
COORDINATE TYPE CONNECTORS TO THE SITE FIBER PATCH PANEL.;
***VENDOR MUST FOLLOW MIAMI NAP PROCEDURES FOR EXTENSION
FROM THEIR POINT OF PRESENCE TO THE DISA SDP AS
DIRECTED BY SITE PERSONNEL AS STATED IN THE PURPOSE***;
B. VENDOR MUST SCHEDULE/COORDINATE WITH THE POC'S LISTED
ON THIS ORDER 72 HOURS IN ADVANCE PRIOR TO SITE
SURVEYS OR INSTALLATIONS.;
C. THE CIRCUIT MUST BE TAGGED WITH THE LOCAL CIRCUIT
ID AND LONG HAUL CKT NO. AT SITE FDP IN THE MPR ROOM
AND THE DROP SIDE OF THE LOCAL ACCESS PROVIDERS
FDP INSTALLED IN THEIR EQUIPMENT SUITE.;
D. TERREMARK PERSONNEL ARE RESPONSIBLE FOR INSTALLATION
AND MAINTENANCE OF SINGLE MODE FIBER FROM THE LINE
SIDE OF THE SITE PROVIDED FIBER TERMINATING PATCH
PANEL TERREMARK BLDG, MEET POINT ROOM (MPR), TO THE
LINE SIDE OF SITE PROVIDED FIBER TERMINATING PATCH
PANEL TERREMARK BLDG, ROOM 356, USING EXISTING
IN-HOUSE SINGLE-MODE FIBER.
(1) COMMERCIAL FIBER POINT OF PRESENCE (COMMERCIAL
CARRIER SYSTEM);
(2) FIBER CABLE X-CONNECT, IN-HOUSE, INSIDE WIRE,
SINGLE-MODE, 1310NM, TELCO;
(3) FIBER TERMINATING PATCH PANEL (SITE PROVIDED)
(4) FIBER CABLE X-CONNECT, IN-HOUSE, INSIDE WIRE,
SINGLE-MODE, 1310NM, TERREMARK PERSONNEL;
AMPLIFYING INFO:
A. VENDOR IS RESPONSIBLE FOR INSTALLATION AND MAINTENANCE
OF SINGLE MODE FIBER FROM THE DROP SIDE OF THE
COMMERCIAL FIBER POINT OF PRESENCE [FIBER DISTRIBUTION
PANEL (FDP)] TERREMARK BLDG, MEET POINT ROOM (MPR) TO
THE LINE SIDE OF THE SITE PROVIDED FIBER TERMINATING
PATCH PANEL TERREMARK BLDG, MEET POINT ROOM (MPR).
COORDINATE TYPE CONNECTORS TO THE SITE FIBER PATCH PANEL.;
***VENDOR MUST FOLLOW MIAMI NAP PROCEDURES FOR EXTENSION
FROM THEIR POINT OF PRESENCE TO THE DISA SDP AS
DIRECTED BY SITE PERSONNEL AS STATED IN THE PURPOSE***;
B. VENDOR MUST SCHEDULE/COORDINATE WITH THE POC'S LISTED
ON THIS ORDER 72 HOURS IN ADVANCE PRIOR TO SITE
SURVEYS OR INSTALLATIONS.;
C. THE CIRCUIT MUST BE TAGGED WITH THE LOCAL CIRCUIT
ID AND LONG HAUL CKT NO. AT SITE FDP IN THE MPR ROOM
AND THE DROP SIDE OF THE LOCAL ACCESS PROVIDERS
FDP INSTALLED IN THEIR EQUIPMENT SUITE.;
D. TERREMARK PERSONNEL ARE RESPONSIBLE FOR INSTALLATION
AND MAINTENANCE OF SINGLE MODE FIBER FROM THE LINE
SIDE OF THE SITE PROVIDED FIBER TERMINATING PATCH
PANEL TERREMARK BLDG, MEET POINT ROOM (MPR), TO THE
LINE SIDE OF SITE PROVIDED FIBER TERMINATING PATCH
PANEL TERREMARK BLDG, ROOM 356, USING EXISTING
IN-HOUSE SINGLE-MODE FIBER.
Location B, INTERFACE change from:
INTERFACE: SONET OC-12C; ELECTRICAL: OPTICAL; PHYSICAL: SNAPCLICK (SC); (PHYSICAL) SNAP CLICK (SC);
(ELECTRICAL) OPTICAL
To:
INTERFACE: SONET OC-12C; ELECTRICAL: OPTICAL; PHYSICAL: SNAP CLICK (SC); (PHYSICAL) SNAP CLICK (SC);
(ELECTRICAL) OPTICAL
File details come from the government source that posted it.