Location A, LOCATION OF TERMINATION A change from:

ADDRESS: (BLDG) 291; 80 TRUMAN AVENUENAS/TRUMAN ANNEX; KEY WEST, FL, 33040

ROOM: 210-B; 1 FL

LOCATION: TRMNANNX

To:

ADDRESS: (BLDG) 1279; 20 TRUMAN AVENUENAS/TRUMAN ANNEX; KEY WEST, FL, 33040

ROOM: 126; 1 FL

LOCATION: TRMNANNX

Location A, DEMARK change from:

(BLDG) 291; RM 210-B

80 TRUMAN AVENUE

NAS/TRUMAN ANNEX; KEY WEST, FL 33040

To:

(BLDG) 1279; RM 126

20 TRUMAN AVENUE

NAS/TRUMAN ANNEX; KEY WEST, FL 33040

Location A, UNIQUE INSTALLATION FACTORS change from:

(1) FIBER CABLE X-CONNECT, IN-HOUSE, INSIDE WIRE,

SINGLE-MODE, 1310NM, TELCO;

(2) COMMERCIAL FIBER POINT OF PRESENCE (COMMERCIAL CARRIER

SYSTEM);

AMPLIFYING INFO:;

A. VENDOR IS RESPONSIBLE FOR INSTALLATION AND MAINTENANCE

OF SINGLE MODE FIBER FROM THE LINE SIDE OF THE DISA

IE1 PROVIDED FIBER TERMINATING PATCH PANEL INSTALLED

IN THE MSPP SUITE (UMSWTRN010) BLDG 291, ROOM 210-B

TO THE DROP SIDE OF THE COMMERCIAL FIBER POINT OF

PRESENCE FIBER DISTRIBUTION PANEL (FDP) BLDG 291, ROOM

210-B. TERMINATE WITH "SC" CONNECTORS FROM DISA

PROVIDED FIBER TERMINATING PATCH PANEL.;

B. VENDOR MUST PROVIDE FIBER STRANDS FROM THE MSPP SUITE

LOCATION TO THE COMMERCIAL DEMARC WITHOUT SPLICING AND

OR USE OF CONNECTORS TO CONNECT 2 OR MORE FIBER STRANDS

MEANING THE FIBER CANNOT BE BROKEN IN THE MIDDLE MUST

BE CONTINUOUS.;

C. THE CIRCUIT MUST BE TAGGED WITH THE LOCAL CIRCUIT ID

AND LONG HAUL CIRCUIT NO. AT THE DROP SIDE OF THE

COMMERCIAL DEMARC LOCATION BLDG 291, ROOM 210-B.

ADDITIONALLY, VENDOR MUST SHOW SITE PERSONNEL LISTED

ON THIS ORDER THE EXACT TERMINATION POINTS WHEN

INSTALLATION IS COMPLETE.;

D. VENDOR MUST SCHEDULE/COORDINATE WITH THE POC'S LISTED

ON THIS ORDER 72 HOURS IN ADVANCE PRIOR TO SITE

SURVEYS OR INSTALLATIONS.

(1) FIBER CABLE X-CONNECT, IN-HOUSE, INSIDE WIRE,

SINGLE-MODE, 1310NM, TELCO;

(2) COMMERCIAL FIBER POINT OF PRESENCE

(3) FIBER CABLE X-CONNECT, IN-HOUSE, INSIDE WIRE,

SINGLE-MODE, 1310NM, TELCO;

(4) COMMERCIAL FIBER POINT OF PRESENCE;

AMPLIFYING INFO:;

A. JIATFS J6 PERSONNEL ARE RESPONSIBLE FOR INSTALLATION

AND MAINTENANCE OF SINGLE MODE FIBER FROM LINE SIDE

OF SITE PROVIDED FIBER TERMINATING PATCH PANEL BLDG

291, ROOM 210-B TO LINE SIDE OF SITE PROVIDED FIBER

TERMINATING PATCH PANEL BLDG 1279, ROOM 126.

B. VENDOR IS RESPONSIBLE FOR INSTALLATION AND

MAINTENANCE OF SINGLE MODE FIBER FROM DROP SIDE OF

SITE PROVIDED FIBER TERMINATING PATCH PANEL BLDG

1279, ROOM 126 TO DROP SIDE OF COMMERCIAL FIBER

POINT OF PRESENCE FIBER DISTRIBUTION PANEL BLDG

1279, ROOM 126. COORDINATE TYPE CONNECTORS FOR

TERMINATION TO SITE PROVIDED PATCH PANEL.

COORDINATE WITH SITE PERSONNEL FOR FIBER PAIR

ASSIGNMENTS TO SITE PROVIDED FIBER TERMINATING

PATCH PANEL IN BLDG 1279, ROOM 126 CORRESPONDING

TO FIBER TERMINATIONS TO SITE PROVIDED TERMINATING

PATCH PANEL IN BLDG 291.;

C. VENDOR MUST COORDINATE WITH GOVERNMENT SITE

PERSONNEL TO CONDUCT WALK THROUGH SITE SURVEY FOR

EXACT CABLE FT. FROM SITE PROVIDED FIBER

TERMINATING PATCH PANEL BLDG 1279, ROOM 126 TO THE

COMMERCIAL FIBER POINT OF PRESENCE BLDG 1279, ROOM 126.;

D. VENDOR MUST PROVIDE FIBER STRANDS FROM DISA

PROVIDED FIBER PATCH PANEL INSTALLED IN JUNIPER

ROUTER TO THE COMMERCIAL DEMARC LOCATION WITHOUT

SPLICING AND OR USE OF CONNECTORS TO CONNECT 2 OR

MORE FIBER STRANDS MEANING THE FIBER CANNOT BE

BROKEN IN THE MIDDLE AND MUST BE CONTINUOUS.;

E. CIRCUIT MUST BE TAGGED WITH LOCAL CIRCUIT ID AND

LONG HAUL CIRCUIT NO. AT DROP SIDE OF COMMERCIAL

DEMARC AND SITE PROVIDED FIBER PATCH PANEL BLDG

1279, ROOM 126. ADDITIONALLY, VENDOR MUST SHOW SITE

PERSONNEL LISTED ON THIS ORDER THE EXACT

TERMINATION POINT WHEN INSTALLATION IS COMPLETE.;

F. VENDOR MUST SCHEDULE/COORDINATE WITH POC'S

LISTED ON THIS ORDER 72 HOURS IN ADVANCE PRIOR TO SITE

SURVEYS OR INSTALLATIONS.

Location A, INTERFACE change from:

INTERFACE: SONET OC-12C; ELECTRICAL: OPTICAL; PHYSICAL: SNAPCLICK (SC); (PHYSICAL) SNAP CLICK (SC);

(ELECTRICAL) OPTICAL

To:

INTERFACE: SONET OC-12C; ELECTRICAL: OPTICAL; PHYSICAL: SNAP CLICK (SC); (PHYSICAL) SNAP CLICK (SC);

(ELECTRICAL) OPTICAL

Location A, TERMINAL EQUIPMENT change from:

EQUIPMENT INFORMATION: COMMERCIAL FIBER POINT OF PRESENCE

To:

EQUIPMENT INFORMATION: FIBER TERMINATING PATCH PANEL (GFE) (SITE PROVIDED) (TO B291); COMMERCIAL

FIBER POINT OF PRESENCE

Location B, LOCATION OF TERMINATION B change from:

ADDRESS: (BLDG) TERREMARK BLDG (NAP); 50 NE 9TH STREET; MIAMI, FL 33132

ROOM: 356; 3RD FL

LOCATION: MIAMINAP

ADDRESS: (BLDG) TERREMARK BLDG (NAP); 50 NE 9TH STREET; MIAMI, FL 33132

ROOM: Meet Point Room (MPR); 2 FL

LOCATION: MIAMINAP

Location B, DEMARK change from:

(BLDG) TERREMARK BLDG (NAP);

RM 356

50 NE 9TH STREET; MIAMI, FL 33132

To:

(BLDG) TERREMARK BLDG (NAP);

50 NE 9TH STREET; MIAMI, FL 33132

Location B, UNIQUE INSTALLATION FACTORS change from:

(1) COMMERCIAL FIBER POINT OF PRESENCE (COMMERCIAL

CARRIER SYSTEM);

(2) FIBER CABLE X-CONNECT, IN-HOUSE, INSIDE WIRE,

SINGLE-MODE, 1310NM, TELCO;

(3) FIBER TERMINATING PATCH PANEL (SITE PROVIDED)

(4) FIBER CABLE X-CONNECT, IN-HOUSE, INSIDE WIRE,

SINGLE-MODE, 1310NM, TERREMARK PERSONNEL;

AMPLIFYING INFO:;

A. VENDOR IS RESPONSIBLE FOR INSTALLATION AND MAINTENANCE

OF SINGLE MODE FIBER FROM THE DROP SIDE OF THE

COMMERCIAL FIBER POINT OF PRESENCE [FIBER DISTRIBUTION

PANEL (FDP)] TERREMARK BLDG, MEET POINT ROOM (MPR) TO

THE LINE SIDE OF THE SITE PROVIDED FIBER TERMINATING

PATCH PANEL TERREMARK BLDG, MEET POINT ROOM (MPR).

COORDINATE TYPE CONNECTORS TO THE SITE FIBER PATCH PANEL.;

***VENDOR MUST FOLLOW MIAMI NAP PROCEDURES FOR EXTENSION

FROM THEIR POINT OF PRESENCE TO THE DISA SDP AS

DIRECTED BY SITE PERSONNEL AS STATED IN THE PURPOSE***;

B. VENDOR MUST SCHEDULE/COORDINATE WITH THE POC'S LISTED

ON THIS ORDER 72 HOURS IN ADVANCE PRIOR TO SITE

SURVEYS OR INSTALLATIONS.;

C. THE CIRCUIT MUST BE TAGGED WITH THE LOCAL CIRCUIT

ID AND LONG HAUL CKT NO. AT SITE FDP IN THE MPR ROOM

AND THE DROP SIDE OF THE LOCAL ACCESS PROVIDERS

FDP INSTALLED IN THEIR EQUIPMENT SUITE.;

D. TERREMARK PERSONNEL ARE RESPONSIBLE FOR INSTALLATION

AND MAINTENANCE OF SINGLE MODE FIBER FROM THE LINE

SIDE OF THE SITE PROVIDED FIBER TERMINATING PATCH

PANEL TERREMARK BLDG, MEET POINT ROOM (MPR), TO THE

LINE SIDE OF SITE PROVIDED FIBER TERMINATING PATCH

PANEL TERREMARK BLDG, ROOM 356, USING EXISTING

IN-HOUSE SINGLE-MODE FIBER.

(1) COMMERCIAL FIBER POINT OF PRESENCE (COMMERCIAL

CARRIER SYSTEM);

(2) FIBER CABLE X-CONNECT, IN-HOUSE, INSIDE WIRE,

SINGLE-MODE, 1310NM, TELCO;

(3) FIBER TERMINATING PATCH PANEL (SITE PROVIDED)

(4) FIBER CABLE X-CONNECT, IN-HOUSE, INSIDE WIRE,

SINGLE-MODE, 1310NM, TERREMARK PERSONNEL;

AMPLIFYING INFO:

A. VENDOR IS RESPONSIBLE FOR INSTALLATION AND MAINTENANCE

OF SINGLE MODE FIBER FROM THE DROP SIDE OF THE

COMMERCIAL FIBER POINT OF PRESENCE [FIBER DISTRIBUTION

PANEL (FDP)] TERREMARK BLDG, MEET POINT ROOM (MPR) TO

THE LINE SIDE OF THE SITE PROVIDED FIBER TERMINATING

PATCH PANEL TERREMARK BLDG, MEET POINT ROOM (MPR).

COORDINATE TYPE CONNECTORS TO THE SITE FIBER PATCH PANEL.;

***VENDOR MUST FOLLOW MIAMI NAP PROCEDURES FOR EXTENSION

FROM THEIR POINT OF PRESENCE TO THE DISA SDP AS

DIRECTED BY SITE PERSONNEL AS STATED IN THE PURPOSE***;

B. VENDOR MUST SCHEDULE/COORDINATE WITH THE POC'S LISTED

ON THIS ORDER 72 HOURS IN ADVANCE PRIOR TO SITE

SURVEYS OR INSTALLATIONS.;

C. THE CIRCUIT MUST BE TAGGED WITH THE LOCAL CIRCUIT

ID AND LONG HAUL CKT NO. AT SITE FDP IN THE MPR ROOM

AND THE DROP SIDE OF THE LOCAL ACCESS PROVIDERS

FDP INSTALLED IN THEIR EQUIPMENT SUITE.;

D. TERREMARK PERSONNEL ARE RESPONSIBLE FOR INSTALLATION

AND MAINTENANCE OF SINGLE MODE FIBER FROM THE LINE

SIDE OF THE SITE PROVIDED FIBER TERMINATING PATCH

PANEL TERREMARK BLDG, MEET POINT ROOM (MPR), TO THE

LINE SIDE OF SITE PROVIDED FIBER TERMINATING PATCH

PANEL TERREMARK BLDG, ROOM 356, USING EXISTING

IN-HOUSE SINGLE-MODE FIBER.

Location B, INTERFACE change from:

INTERFACE: SONET OC-12C; ELECTRICAL: OPTICAL; PHYSICAL: SNAPCLICK (SC); (PHYSICAL) SNAP CLICK (SC);

(ELECTRICAL) OPTICAL

To:

INTERFACE: SONET OC-12C; ELECTRICAL: OPTICAL; PHYSICAL: SNAP CLICK (SC); (PHYSICAL) SNAP CLICK (SC);

(ELECTRICAL) OPTICAL