TEST & ACCEPTANCE INSTRUCTIONS: CONUS OC-24 VENDOR MUST DELIVER OC-24 SERVICE 2W

(UNPROTECTED). REQUEST VENDOR PROVIDE LIGHT LEVEL READINGS (DB LOSS) ON EXTENSION FROM THE COMMERCIAL POP TO THE GOVERNMENT SERVICE. DELIVERY POINT (SDP) AT BOTH LOCATIONS.

LIGHT LEVELS MUST BE ADJUSTED TO -3 TO -9. VENDOR MUST CONTACT IMPLEMENTATION

ASSISTANCE TO ESTABLISH THE COORDINATION AND ACTIVATION PROCESS FOR TURN-UP OR ANY SITE CONTACT ISSUES. VENDOR REQUIRED TO HAVE CIRCUIT VISIBILITY TO ASSIST IN ANY CIRCUIT OUTAGES.

VENDOR MUST HAVE A 24X7 NETWORK OPERATIONS CENTER. ONE-HOUR RESPONSE TIME TURN-

AROUND TO REPAIR ONCE TROUBLE-CALL HAS BEEN REPORTED.

TECHNICAL SPECIFICATIONS FIBER TERMINATION: OPTICAL, SINGLE MODE, 1310NM PHYSICAL

TERMINATION: SC/SC CONNECTORS FRAME FORMAT: STS-24 RATE: PLUS OR MINUS 20 PPM

CHANNELIZATION REQUIRED: NO CONCATENATION REQUIRED: NO GFE CLOCKING: VENDOR ESFU (OR EQUIVALENT) NOT TO BE ENGINEERED INTO CIRCUIT. NO NETWORK INTERFACE UNIT DEDICATED PATH LINE MUST REMAIN FULLY OPERATIONAL AND AVAILABLE TO USERS 24 HOURS A DAY, SEVEN DAYS PER

WEEK, AT LEAST 99.5% OR BETTER.

TESTING PARAMETERS AND THRESHOLDS: ERROR PERFORMANCE (AVAILABILITY, SES, DM, EFS) AND LOSS OF BIT COUNT INTEGRITY SHALL BE MEASURED AND RECORDED OVER THE DURATION OF THE CONTIGUOUS 72 HOUR TESTING INTERVAL AND SHALL BE MEASURED AND RECORDED PER DEFINITION

IN ITU RECOMMENDATION G.826 AND M.2100.

IMPLEMENTATION ASSISTANCE CONTINUED: FOR DISN CORE / DEDICATED / NIPRNET / SIPRNET / VPN CIRCUIT ACTIVATION ASSISTANCE OR SERVICE IMPLEMENTATION INQUIRIES/SCHEDULING, CONTACT THE DISA GLOBAL RF A CTIVATIONS TEAM VIA EMAIL, DISA.SCOTT.CONUS.MBX.RF-CIRCUIT-ACTIVA

TIONS@MAIL.MIL, OR CALL DSN 770-8627; COML 618-220-8627.