CIRCUIT PARAMETERS AND TESTING REQUIREMENTS FOR SOLICITATION HC101318QA789
View the file
Other files
| File | Type | Posted |
|---|---|---|
| HC101318QA789.v1.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CIRCUIT PARAMETERS AND TESTING REQUIREMENTS FOR SOLICITATION HC101318QA789
CIRCUIT SPECIFICATIONS: CONUS TERRESTRIAL- 44.736 MB,
B3ZS/C-BIT CLEAR CHANNEL
1) VENDOR TECHNICAL SPECIFICATIONS
LINE CODING: B3ZS
FRAME FORMAT: C-BIT PARITY
CHANNELIZATION: CLEAR CHANNEL
PHYSICAL TERMINATION: COAX, BNC CONNECTOR
TEST INTERVAL: 24 HOURS
AVAILABILITY: 99.5 %
% ERROR FREE SECONDS (EFS): 98.0 %
SEVERELY ERRORED SECONDS (SES): < 0.02 %
AVERAGE BIT ERROR RATE (BER): 5 X 10-9
RESIDUAL BIT ERROR RATE (RBER): 5 X 10-9
BIPOLAR VIOLATION (BPV): 0 ALLOWED
OUT OF FRAME: 0 ALLOWED
FRAME SLIP: < 1 IN 24 HOURS
DEGRADED MINUTES (DM): < 0.2 %
ROUND TRIP DELAY (RTD): < 10 MS FOR FIRST 620 MILE PLUS 1 MS FOR
EVERY 62 MILES THERE AFTER.
LOSS OF BIT COUNT INTEGRITY (LBCI): < 1 IN 24 HOURS
JITTER: ITU-T G.823 OR COMPARABLE U.S. COMMERCIAL INDUSTRY
STANDARD
TEST PATTERN: QRSS FOR DSN CIRCUITS; 2^23 FOR ALL OTHER SERVICE
TYPES
CONUS SECOND PART OF DS-3 CIRCUIT PARAMETERS
2) VENDOR WILL TEST COMMERCIAL END TO END, IF THE VENDOR EXTENDED
THE SERVICE THEN THE TEST MUST BE TO THE END OF THE EXTENSION.
TEST WILL NOT BE COMPLETED WITH LOOPS.
3) VENDOR MUST CONDUCT WALK-THROUGH SITE SURVEY PRIOR TO
INSTALLATION AT ALL TERMINATING GOVERNMENT LOCATIONS IF A CIRCUIT
EXTENSION IS REQUIRED.
4) VENDOR MUST COORDINATE SITE VISIT WITH LOCATIONS POC 72 HOURS
IN ADVANCE PRIOR TO COORDINATE ACCESS TO FACILITIES.
5) VENDOR MUST CONTACT DISA IMPLEMENTATION ASSISTANCE TO
ESTABLISH THE COORDINATION AND ACTIVATION PROCESS FOR CIRCUIT
TURN-UP AND/OR ANY SITE CONTACT ISSUES.
6) VENDOR INSTALLATION AND MAINTENANCE INSTRUCTION: IAW THE
UNIQUE INSTALLATION FACTORS IN PARAGRAPH 3.
7) VENDOR REQUIRED TO HAVE CIRCUIT VISIBILITY TO ASSIST IN ANY
CIRCUIT OUTAGES.
8) VENDOR MUST HAVE A 24X7 NETWORK OPERATIONS CENTER.
9) REQUEST ONE-HOUR RESPONSE TIME TURN-AROUND TO REPAIR ONCE
TROUBLE-CALL HAS BEEN REPORTED.
10) THE VENDOR TEST SET/SETS MUST HAVE THE ABILITY TO PRINT OR
ELECTRONICALLY OUTPUT THE TEST RESULTS AND THOSE RESULTS MUST BE
E-MAILED TO THE ACCEPTING AUTHORITY FOR REVIEW.
11) ALL EQUIPMENT AND CIRCUIT PROBLEMS WILL BE REPORTED TO DISA
CONUS: (C) 618-220-9950 TOLL FREE: 855-868-9950
12) VENDOR MUST PROVIDE THE LONG HAUL CIRCUIT NO. AND LEC CKT ID
PRIOR TO TURN UP TO THE GOVERNMENT.
13) CIRCUIT OPERATIONS: DEDICATED PATH - 24 HOURS A DAY, SEVEN
DAYS PER WEEK
A. COMPLETION REPORT: STATION DESIGNATED IN PARAGRAPH 2H AS CCO/CMO
WILL SUBMIT COMPLETION REPORT IAW DISAC 310-130-1, SUPP 1, 2, 3
FORMAT OR DISAC 310-70-1. REPORT WILL BE ADDRESSED TO ORIGINATOR
AND ALL ADDRESSEES OF THIS TSO.
B. DD FORM 1368: DD FORM 1368'S (MODIFIED USE OF LEASED
COMMUNICATION FACILITIES), OR EMAIL EQUIVALENT, WILL BE
SUBMITTED, AS REQUIRED, ON THIS CIRCUIT IAW DISAC-DITCO 350-135-1
BY THE STATION DESIGNATED IN PARAGRAPH 2H AS CCO/CMO. GUIDANCE
ON SUBMISSION IS AVAILABLE AT
HTTP://WWW.DITCO.DISA.MIL/CORPORATELIBRARY/HOME.ASP. CLICK ON
"350-135-1, DEFENSE COMMERCIAL COMMUNICATIONS ACQUISITION
PROCEDURES."
C. IMPLEMENTATION ASSISTANCE: FOR DISN CORE / DEDICATED / NIPRNET /
SIPRNET / VPN CIRCUIT ACTIVATION ASSISTANCE OR SERVICE IMPLEMENTA
TION INQUIRIES/SCHEDULING, CONTACT THE DISA GLOBAL RF ACTIVATIONS
TEAM VIA EMAIL, DISA.SCOTT.CONUS.MBX.RF-CIRCUIT-ACTIVATIONS@MAIL
. MIL, OR CALL DSN 770-8627; COML 618-220-8627.
D. ANY ADDRESSEE ON THE TSO WILL NOTIFY ALL
ADDRESSEES IMMEDIATELY BY MESSAGE IDENTIFYING ANY ISSUES,
PROBLEMS, OR SITUATIONS WHICH MAY PREVENT OR DELAY THE
IMPLEMENTATION OF THIS TELECOMMUNICATIONS SERVICE ORDER (TSO).
ALL STATIONS WILL REVIEW THE CONFIGURATION, EQUIPMENT, CONTACT
NUMBERS AND ADDRESSES CONTAINED IN THIS TSO AND PROVIDE UPDATES
TO ORIGINATOR OF TSO ANY ERRORS SO THAT SUBSEQUENT TSOS MAY BE
UPDATED.
E. UNSATISFACTORY SERVICE REPORTING INSTRUCTIONS: FOR UNSATISFACTORY
SERVICE OR TO REPORT EQUIPMENT AND/OR CIRCUIT PROBLEMS INVOLVING
DISA PROVIDED TRANSPORT AND/OR EQUIPMENT, PLEASE CONTACT THE
DISN CUSTOMER CONTACT CENTER (DCCC) TOLL FREE NUMBER IS
1-844-347-2457 (1-844-DISA HLP) OPTION 2, COML 1-614-692-0032
OPTION 2, DSN 312-850-0032 OPTION 2.