About this file

CIRCUIT PARAMETERS AND TESTING REQUIREMENTS FOR SOLICITATION HC101318QA789

View the file

Other files

File Type Posted
HC101318QA789.v1.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CIRCUIT PARAMETERS AND TESTING REQUIREMENTS FOR SOLICITATION HC101318QA789

CIRCUIT SPECIFICATIONS: CONUS TERRESTRIAL- 44.736 MB,

B3ZS/C-BIT CLEAR CHANNEL

1) VENDOR TECHNICAL SPECIFICATIONS

LINE CODING: B3ZS

FRAME FORMAT: C-BIT PARITY

CHANNELIZATION: CLEAR CHANNEL

PHYSICAL TERMINATION: COAX, BNC CONNECTOR

TEST INTERVAL: 24 HOURS

AVAILABILITY: 99.5 %

% ERROR FREE SECONDS (EFS): 98.0 %

SEVERELY ERRORED SECONDS (SES): < 0.02 %

AVERAGE BIT ERROR RATE (BER): 5 X 10-9

RESIDUAL BIT ERROR RATE (RBER): 5 X 10-9

BIPOLAR VIOLATION (BPV): 0 ALLOWED

OUT OF FRAME: 0 ALLOWED

FRAME SLIP: < 1 IN 24 HOURS

DEGRADED MINUTES (DM): < 0.2 %

ROUND TRIP DELAY (RTD): < 10 MS FOR FIRST 620 MILE PLUS 1 MS FOR

EVERY 62 MILES THERE AFTER.

LOSS OF BIT COUNT INTEGRITY (LBCI): < 1 IN 24 HOURS

JITTER: ITU-T G.823 OR COMPARABLE U.S. COMMERCIAL INDUSTRY

STANDARD

TEST PATTERN: QRSS FOR DSN CIRCUITS; 2^23 FOR ALL OTHER SERVICE

TYPES

CONUS SECOND PART OF DS-3 CIRCUIT PARAMETERS

2) VENDOR WILL TEST COMMERCIAL END TO END, IF THE VENDOR EXTENDED

THE SERVICE THEN THE TEST MUST BE TO THE END OF THE EXTENSION.

TEST WILL NOT BE COMPLETED WITH LOOPS.

3) VENDOR MUST CONDUCT WALK-THROUGH SITE SURVEY PRIOR TO

INSTALLATION AT ALL TERMINATING GOVERNMENT LOCATIONS IF A CIRCUIT

EXTENSION IS REQUIRED.

4) VENDOR MUST COORDINATE SITE VISIT WITH LOCATIONS POC 72 HOURS

IN ADVANCE PRIOR TO COORDINATE ACCESS TO FACILITIES.

5) VENDOR MUST CONTACT DISA IMPLEMENTATION ASSISTANCE TO

ESTABLISH THE COORDINATION AND ACTIVATION PROCESS FOR CIRCUIT

TURN-UP AND/OR ANY SITE CONTACT ISSUES.

6) VENDOR INSTALLATION AND MAINTENANCE INSTRUCTION: IAW THE

UNIQUE INSTALLATION FACTORS IN PARAGRAPH 3.

7) VENDOR REQUIRED TO HAVE CIRCUIT VISIBILITY TO ASSIST IN ANY

CIRCUIT OUTAGES.

8) VENDOR MUST HAVE A 24X7 NETWORK OPERATIONS CENTER.

9) REQUEST ONE-HOUR RESPONSE TIME TURN-AROUND TO REPAIR ONCE

TROUBLE-CALL HAS BEEN REPORTED.

10) THE VENDOR TEST SET/SETS MUST HAVE THE ABILITY TO PRINT OR

ELECTRONICALLY OUTPUT THE TEST RESULTS AND THOSE RESULTS MUST BE

E-MAILED TO THE ACCEPTING AUTHORITY FOR REVIEW.

11) ALL EQUIPMENT AND CIRCUIT PROBLEMS WILL BE REPORTED TO DISA

CONUS: (C) 618-220-9950 TOLL FREE: 855-868-9950

12) VENDOR MUST PROVIDE THE LONG HAUL CIRCUIT NO. AND LEC CKT ID

PRIOR TO TURN UP TO THE GOVERNMENT.

13) CIRCUIT OPERATIONS: DEDICATED PATH - 24 HOURS A DAY, SEVEN

DAYS PER WEEK

A. COMPLETION REPORT: STATION DESIGNATED IN PARAGRAPH 2H AS CCO/CMO

WILL SUBMIT COMPLETION REPORT IAW DISAC 310-130-1, SUPP 1, 2, 3

FORMAT OR DISAC 310-70-1. REPORT WILL BE ADDRESSED TO ORIGINATOR

AND ALL ADDRESSEES OF THIS TSO.

B. DD FORM 1368: DD FORM 1368'S (MODIFIED USE OF LEASED

COMMUNICATION FACILITIES), OR EMAIL EQUIVALENT, WILL BE

SUBMITTED, AS REQUIRED, ON THIS CIRCUIT IAW DISAC-DITCO 350-135-1

BY THE STATION DESIGNATED IN PARAGRAPH 2H AS CCO/CMO. GUIDANCE

ON SUBMISSION IS AVAILABLE AT

HTTP://WWW.DITCO.DISA.MIL/CORPORATELIBRARY/HOME.ASP. CLICK ON

"350-135-1, DEFENSE COMMERCIAL COMMUNICATIONS ACQUISITION

PROCEDURES."

C. IMPLEMENTATION ASSISTANCE: FOR DISN CORE / DEDICATED / NIPRNET /

SIPRNET / VPN CIRCUIT ACTIVATION ASSISTANCE OR SERVICE IMPLEMENTA

TION INQUIRIES/SCHEDULING, CONTACT THE DISA GLOBAL RF ACTIVATIONS

TEAM VIA EMAIL, DISA.SCOTT.CONUS.MBX.RF-CIRCUIT-ACTIVATIONS@MAIL

. MIL, OR CALL DSN 770-8627; COML 618-220-8627.

D. ANY ADDRESSEE ON THE TSO WILL NOTIFY ALL

ADDRESSEES IMMEDIATELY BY MESSAGE IDENTIFYING ANY ISSUES,

PROBLEMS, OR SITUATIONS WHICH MAY PREVENT OR DELAY THE

IMPLEMENTATION OF THIS TELECOMMUNICATIONS SERVICE ORDER (TSO).

ALL STATIONS WILL REVIEW THE CONFIGURATION, EQUIPMENT, CONTACT

NUMBERS AND ADDRESSES CONTAINED IN THIS TSO AND PROVIDE UPDATES

TO ORIGINATOR OF TSO ANY ERRORS SO THAT SUBSEQUENT TSOS MAY BE

UPDATED.

E. UNSATISFACTORY SERVICE REPORTING INSTRUCTIONS: FOR UNSATISFACTORY

SERVICE OR TO REPORT EQUIPMENT AND/OR CIRCUIT PROBLEMS INVOLVING

DISA PROVIDED TRANSPORT AND/OR EQUIPMENT, PLEASE CONTACT THE

DISN CUSTOMER CONTACT CENTER (DCCC) TOLL FREE NUMBER IS

1-844-347-2457 (1-844-DISA HLP) OPTION 2, COML 1-614-692-0032

OPTION 2, DSN 312-850-0032 OPTION 2.

File details come from the government source that posted it.