IQO INQUIRY

FM: PL8211

TO: Contractors

DATE (MM/DD/YYYY): 5/1/2018

SUBJECT: HC101318QA767-0002 Amend: 0002

A. TYPE ACTION: AMEND

1. PURPOSE:

*****AMEND 0002 IS TO CHANGE THE DEMARK FROM SCOTT AFB, IL TO OFFUTT AFB, NE

AND UPDATED THE UNIQUE INSTALLATION FACTORS. ALL ELSE REMAINS UNCHANGED.*****

1. SUBMIT A QUOTE TO PROVIDE, INSTALL AND MAINTAIN A LEASED 1GBE (GIGABIT

ETHERNET) IP BACKBONE CIRCUIT BETWEEN BLDG 761 RM 127; FT SNELLING, 760

MILITARY HIGHWAY MINNEAPOLIS, MN 55450 AND BLDG 301D RM 134; 106 PEACEKEEPER

DRIVE, OFFUTT AFB, NE, 68113

SEE UNIQUE INSTALL FACTORS.

VENDORS MUST CLEARLY STATE IN QUOTES THEIR COMPLIANCE WITH GOVERNMENT

TESTING AND ACCEPTANCE REQUIREMENTS

CONTRACTORS SHALL MEET RTD OF 10 MILLISECONDS

2. EACH CONTRACTOR IS RESPONSIBLE FOR READING AND COMPLYING WITH ALL

TECHNICAL ASPECTS OF THIS SOLICITATION, TO INCLUDE READING AND AGREEING

WITH THE STANDARD PROVISIONS, ATTACHMENTS LISTING SPECIFIC TECHNICAL

REQUIREMENTS, PRICE QUOTE REQUIREMENTS, AND REQUESTED SERVICE DATE.

FAILURE TO READ AND ADHERE TO ANY PORTION OF THE INQUIRY SHALL RENDER THE

QUOTE NON-COMPLIANT AND RESULT IN IT BEING EXCLUDED FROM EVALUATION AND

AWARD.

3. THE SERVICE DATE TO BE MET IS: 19 SEP 2018 (SIP). THE GOVERNMENT ASSUMES

THAT CONTRACTORS HAVE CONSIDERED ALL ISSUES THAT MAY IMPACT THE SERVICE

DATE. THE GOVERNMENT MAY CANCEL, TERMINATE, OR REQUEST CONSIDERATION

IAW STANDARD PROVISION 42 FOR FAILURE TO MEET CONTRACTUAL SERVICE DATE OR

COMPLY WITH ANY CONTRACT TERMS OR CONDITIONS.

4. CONTRACTORS SHALL SUBMIT QUOTES IAW STANDARD PROVISION 04. QUOTES

SHALL INCLUDE SUFFICIENT DETAIL FOR EFFECTIVE EVALUATION AND SHOULD

NOT SIMPLY REPHRASE OR RESTATE THE GOVERNMENT REQUIREMENTS. RATHER,

THEY MUST PROVIDE CONVINCING RATIONALE TO ADDRESS HOW THE CONTRACTOR

INTENDS TO MEET THE REQUIREMENT. IN RESPONSE TO THIS SOLICITATION, NO

TERMS OR CONDITIONS PLACED UPON THE GOVERNMENT, NOR ASSUMPTIONS WILL BE

ACCEPTED. CONTRACTORS ARE ENCOURAGED TO SUBMIT QUESTIONS AND REQUEST

CLARIFICATIONS OF THE REQUIREMENT (S) BEFORE SUBMITTING QUOTES. QUESTIONS

HC101318QA767-0002

SHALL BE SUBMITTED TO CONTRACT SPECIALIST AND CONTRACTING OFFICER DURING

THE SOLICITATION PHASE ONLY, AND RESPONSES FOR ALL INTERESTED PARTIES WILL BE

POSTED TO FEDBIZOPPS, QUOTES MUST BE UPLOADED TO IDEAS.

5. ETHERNET TESTING MUST BE COORDINATED WITH CUSTOMER ACCEPTANCE

AUTHORITY AT BOTH LOCATIONS BEFORE NOTICE OF COMPLETION IS SUBMITTED TO

DITCO. FOR DISA ETHERNET REQUIREMENTS THE ACCEPTING AUTHORITY IS: MICHAEL

REEVES, MICHAEL.B.REEVES.CTR@MAIL.MIL (618) 220-8973 OR CLARENCE MOORE,

CLARENCE.S.MOORE.CTR@MAIL.MIL, (618) 220-9935

6. ESTABLISH TSP. TSP0HB98V-01

7. THE COMMITTED INFORMATION RATE (CIR) (1.0GBE) WILL REQUIRE VENDOR TO DELIVER

1.0GB ETHERNET INTERFACE (OPITCAL HANDOFF-1000BASE-LX-SINGLE MODE FIBER) AT

THE DROP SIDE OF THE COMMERCIAL DEMARC'S AT THE "A" AND "Z" LOCATIONS.

8. ETHERNET FRAME SIZE WILL BE CONFIGURED TO SUPPORT MAXIMUM TRANSMISSION

UNIT (MTU) OF 9192 OCTETS (BYTES). NOTE-ETHERNET FRAME SIZE DESIGNATOR 'H' (MTU)

IS EQUAL TO 9192 BYTES.

9. THIS REQUIREMENT MUST BE WORKED IN CONJUNCTION WITH SOLICITATION

HC101318QA735 / TSR RU23FEB185805

M. ADDITIONAL INFORMATION:

3. TSR NUMBER: RU23FEB185810B

4. CCSD: BBLF

Z. DITCO CONTACT:

Robert Spencer

618-229-9181 robert.e.spencer.civ@mail.mil

Angelina Hutson

DITCO Contracting Officer

Unless otherwise specified, all other terms and conditions are unchanged.

Paragraph E.SERVICE DATE change from:

Sep 19, 2018

To:

Jul 6, 2018

Location B, LOCATION OF TERMINATION B change from:

ADDRESS: BLDG 1575 RM C1-B; 103 WEST LOSEY STREET, SCOTT AFB, IL, 62225

ROOM: TDF; 1ST FL

LOCATION: SCOTTAFB

ADDRESS: (BLDG) 301D 106 PEACEKEEPER DRIVE OFFUTT AIR FORCE BASE, NE 68113

ROOM: 134

LOCATION: OFFUTTAF

Location B, DEMARK change from:

BLDG 1575 RM C1-B; 103 WEST LOSEY STREET, SCOTT AFB, IL, 62225

To:

(BLDG) 301D (RM) 134 (FL) NA

106 PEACEKEEPER DRIVE

OFFUTT AIR FORCE BASE, NE 68113

PRI: SHIFT SUPERVISOR D271-3210 C402-294-3210

EMAIL: TECH.CONTROL.3@US.AF.MIL ALT: CIRCUIT ACTIONS D271-6959,

C402-294-6959

EMAIL: CIRCUIT.ACTIONS8@US.AF.MIL ORG EMAIL: CIRCUIT.ACTIONS8@US.AF.MIL

Location B, UNIQUE INSTALLATION FACTORS change from:

AMPLIFYING INFO:

A. VENDOR IS RESPONSIBLE FOR INSTALLATION AND MAINTENANCE OF THE SERVICE FROM THE LINE SIDE OF

THE DISA IE1 PROVIDED FIBER TERMINATING PATCH PANEL INSTALLED IN THE CISCO ASR-9010 ROUTER SUITE

(UJEWSCO030) BLDG 1575, ROOM C1B TO THE DROP SIDE OF THE COMMERCIAL FIBER POINT OF PRESENCE FIBER

DISTRIBUTION PANEL BLDG 1575, ROOM C1B USING SINGLE MODE FIBER. COORDINATE TYPE CONNECTORS TO BE

USED FOR TERMINATION TO THE DISA PROVIDED PATCH PANEL.

B. VENDOR MUST COORDINATE WITH GOVERNMENT SITE PERSONNEL TO CONDUCT WALK THROUGH SITE

SURVEYS FOR EXACT CABLE FT. FROM THE DISA PROVIDED FIBER TERMINATING PATCH PANEL INSTALLED IN THE

CISCO ASR-9010 ROUTER SUITE BLDG 1575, ROOM C1B TO THE COMMERCIAL FIBER POINT OF PRESENCE BLDG

1575, ROOM C1B.

C. VENDOR MUST PROVIDE FIBER STRANDS FROM THE DISA PROVIDED FIBER PATCH PANEL INSTALLED IN THE

CISCO ASR-9010 ROUTER TO THE COMMERCIAL DEMARC LOCATION WITHOUT SPLICING AND OR USE OF

CONNECTORS TO CONNECT 2 OR MORE FIBER STRANDS MEANING THE FIBER CANNOT BE BROKEN IN THE

MIDDLE AND MUST BE CONTINUOUS.

D. VENDOR MUST SCHEDULE/COORDINATE WITH THE POC'S LISTED ON THIS ORDER 72 HOURS IN ADVANCE PRIOR

TO SITE SURVEYS OR INSTALLATIONS.

(1) FIBER CABLE X-CONNECT, IN-HOUSE, INSIDE WIRE, SINGLE-MODE, 1310NM, TELCO

(2) TELCO MULTIPLEX (COMMERCIAL FIBER POINT OF PRESENCE) COMMERCIAL CARRIER SYSTEM (LOCAL

EXCHANGE CARRIER)

AMPLIFYING INFO:

A. VENDOR IS RESPONSIBLE FOR INSTALLATION AND MAINTENANCE OF THE SERVICE FROM THE LINE SIDE OF

THE DISA IE1 PROVIDED FIBER TERMINATING PATCH PANEL INSTALLED IN THE ASR 9010 ROUTER SUITE

(UJEWOFF040) BLDG 301D, ROOM 53 TO THE DROP SIDE OF THE COMMERCIAL FIBER POINT OF PRESENCE FIBER

DISTRIBUTION PANEL BLDG 301D, ROOM 134 USING SINGLE MODE FIBER. COORDINATE TYPE CONNECTORS TO BE

USED FOR TERMINATION TO THE DISA PROVIDED PATCH PANEL.

B. VENDOR MUST COORDINATE WITH GOVERNMENT SITE PERSONNEL TO CONDUCT WALK THROUGH SITE

SURVEYS FOR EXACT CABLE FT. FROM THE DISA PROVIDED FIBER TERMINATING PATCH PANEL INSTALLED IN THE

ASR 9010 ROUTER SUITE BLDG 301D, ROOM 53 TO THE COMMERCIAL FIBER POINT OF PRESENCE BLDG 301D, ROOM 134.

C. VENDOR MUST PROVIDE FIBER STRANDS FROM THE DISA PROVIDED FIBER PATCH PANEL INSTALLED IN THE

ASR 9010 ROUTER TO THE COMMERCIAL DEMARC LOCATION WITHOUT SPLICING AND OR USE OF CONNECTORS

TO CONNECT 2 OR MORE FIBER STRANDS MEANING THE FIBER CANNOT BE BROKEN IN THE MIDDLE AND MUST BE

CONTINUOUS.

D. VENDOR MUST SCHEDULE/COORDINATE WITH THE POC'S LISTED ON THIS ORDER 72 HOURS IN ADVANCE PRIOR

TO SITE SURVEYS OR INSTALLATIONS. 2 OR MORE FIBER STRANDS MEANING THE FIBER CANNOT BE BROKEN IN

THE MIDDLE AND MUST BE CONTINUOUS. VENDOR MUST SCHEDULE/COORDINATE WITH THE POC'S LISTED ON

THIS ORDER 72 HOURS IN ADVANCE PRIOR TO SITE SURVEYS OR INSTALLATIONS.

Location B, CONTACT change from:

PRI: STEPHEN CLABAUGH

D490-0421

C314-260-0421

EMAIL: STEPHEN.G.CLABAUGH.CIV@MAIL.MIL

ALT: JASON NOLEN

D490-0431

C314-260-0431

EMAIL: JASON.L.NOLEN2.CIV@MAIL.MIL

ORG EMAIL: DISA.STLOUIS.ESD.MBX.NODE-SITE-COORDINATOR@MAIL.MIL

To:

PRI: SHIFT SUPERVISOR D271-3210 C402-294-3210

EMAIL: TECH.CONTROL.3@US.AF.MIL ALT: CIRCUIT ACTIONS D271-6959,

C402-294-6959

EMAIL: CIRCUIT.ACTIONS8@US.AF.MIL ORG EMAIL: CIRCUIT.ACTIONS8@US.AF.MIL

Location B, NPA/NXX change from:

314/260

402/232