HC101318QA767-0002.v0.pdf
PDF 12 KB Posted
- Solicitation number
- HC101318QA767
- Issued by
-
Defense Information Systems Agency
About this file
Amend 0002 PDF
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
IQO INQUIRY
FM: PL8211
TO: Contractors
DATE (MM/DD/YYYY): 5/1/2018
SUBJECT: HC101318QA767-0002 Amend: 0002
A. TYPE ACTION: AMEND
1. PURPOSE:
*****AMEND 0002 IS TO CHANGE THE DEMARK FROM SCOTT AFB, IL TO OFFUTT AFB, NE
AND UPDATED THE UNIQUE INSTALLATION FACTORS. ALL ELSE REMAINS UNCHANGED.*****
1. SUBMIT A QUOTE TO PROVIDE, INSTALL AND MAINTAIN A LEASED 1GBE (GIGABIT
ETHERNET) IP BACKBONE CIRCUIT BETWEEN BLDG 761 RM 127; FT SNELLING, 760
MILITARY HIGHWAY MINNEAPOLIS, MN 55450 AND BLDG 301D RM 134; 106 PEACEKEEPER
DRIVE, OFFUTT AFB, NE, 68113
SEE UNIQUE INSTALL FACTORS.
VENDORS MUST CLEARLY STATE IN QUOTES THEIR COMPLIANCE WITH GOVERNMENT
TESTING AND ACCEPTANCE REQUIREMENTS
CONTRACTORS SHALL MEET RTD OF 10 MILLISECONDS
2. EACH CONTRACTOR IS RESPONSIBLE FOR READING AND COMPLYING WITH ALL
TECHNICAL ASPECTS OF THIS SOLICITATION, TO INCLUDE READING AND AGREEING
WITH THE STANDARD PROVISIONS, ATTACHMENTS LISTING SPECIFIC TECHNICAL
REQUIREMENTS, PRICE QUOTE REQUIREMENTS, AND REQUESTED SERVICE DATE.
FAILURE TO READ AND ADHERE TO ANY PORTION OF THE INQUIRY SHALL RENDER THE
QUOTE NON-COMPLIANT AND RESULT IN IT BEING EXCLUDED FROM EVALUATION AND
AWARD.
3. THE SERVICE DATE TO BE MET IS: 19 SEP 2018 (SIP). THE GOVERNMENT ASSUMES
THAT CONTRACTORS HAVE CONSIDERED ALL ISSUES THAT MAY IMPACT THE SERVICE
DATE. THE GOVERNMENT MAY CANCEL, TERMINATE, OR REQUEST CONSIDERATION
IAW STANDARD PROVISION 42 FOR FAILURE TO MEET CONTRACTUAL SERVICE DATE OR
COMPLY WITH ANY CONTRACT TERMS OR CONDITIONS.
4. CONTRACTORS SHALL SUBMIT QUOTES IAW STANDARD PROVISION 04. QUOTES
SHALL INCLUDE SUFFICIENT DETAIL FOR EFFECTIVE EVALUATION AND SHOULD
NOT SIMPLY REPHRASE OR RESTATE THE GOVERNMENT REQUIREMENTS. RATHER,
THEY MUST PROVIDE CONVINCING RATIONALE TO ADDRESS HOW THE CONTRACTOR
INTENDS TO MEET THE REQUIREMENT. IN RESPONSE TO THIS SOLICITATION, NO
TERMS OR CONDITIONS PLACED UPON THE GOVERNMENT, NOR ASSUMPTIONS WILL BE
ACCEPTED. CONTRACTORS ARE ENCOURAGED TO SUBMIT QUESTIONS AND REQUEST
CLARIFICATIONS OF THE REQUIREMENT (S) BEFORE SUBMITTING QUOTES. QUESTIONS
HC101318QA767-0002
SHALL BE SUBMITTED TO CONTRACT SPECIALIST AND CONTRACTING OFFICER DURING
THE SOLICITATION PHASE ONLY, AND RESPONSES FOR ALL INTERESTED PARTIES WILL BE
POSTED TO FEDBIZOPPS, QUOTES MUST BE UPLOADED TO IDEAS.
5. ETHERNET TESTING MUST BE COORDINATED WITH CUSTOMER ACCEPTANCE
AUTHORITY AT BOTH LOCATIONS BEFORE NOTICE OF COMPLETION IS SUBMITTED TO
DITCO. FOR DISA ETHERNET REQUIREMENTS THE ACCEPTING AUTHORITY IS: MICHAEL
REEVES, MICHAEL.B.REEVES.CTR@MAIL.MIL (618) 220-8973 OR CLARENCE MOORE,
CLARENCE.S.MOORE.CTR@MAIL.MIL, (618) 220-9935
6. ESTABLISH TSP. TSP0HB98V-01
7. THE COMMITTED INFORMATION RATE (CIR) (1.0GBE) WILL REQUIRE VENDOR TO DELIVER
1.0GB ETHERNET INTERFACE (OPITCAL HANDOFF-1000BASE-LX-SINGLE MODE FIBER) AT
THE DROP SIDE OF THE COMMERCIAL DEMARC'S AT THE "A" AND "Z" LOCATIONS.
8. ETHERNET FRAME SIZE WILL BE CONFIGURED TO SUPPORT MAXIMUM TRANSMISSION
UNIT (MTU) OF 9192 OCTETS (BYTES). NOTE-ETHERNET FRAME SIZE DESIGNATOR 'H' (MTU)
IS EQUAL TO 9192 BYTES.
9. THIS REQUIREMENT MUST BE WORKED IN CONJUNCTION WITH SOLICITATION
HC101318QA735 / TSR RU23FEB185805
M. ADDITIONAL INFORMATION:
3. TSR NUMBER: RU23FEB185810B
4. CCSD: BBLF
Z. DITCO CONTACT:
Robert Spencer
618-229-9181 robert.e.spencer.civ@mail.mil
Angelina Hutson
DITCO Contracting Officer
Unless otherwise specified, all other terms and conditions are unchanged.
Paragraph E.SERVICE DATE change from:
Sep 19, 2018
To:
Jul 6, 2018
Location B, LOCATION OF TERMINATION B change from:
ADDRESS: BLDG 1575 RM C1-B; 103 WEST LOSEY STREET, SCOTT AFB, IL, 62225
ROOM: TDF; 1ST FL
LOCATION: SCOTTAFB
ADDRESS: (BLDG) 301D 106 PEACEKEEPER DRIVE OFFUTT AIR FORCE BASE, NE 68113
ROOM: 134
LOCATION: OFFUTTAF
Location B, DEMARK change from:
BLDG 1575 RM C1-B; 103 WEST LOSEY STREET, SCOTT AFB, IL, 62225
To:
(BLDG) 301D (RM) 134 (FL) NA
106 PEACEKEEPER DRIVE
OFFUTT AIR FORCE BASE, NE 68113
PRI: SHIFT SUPERVISOR D271-3210 C402-294-3210
EMAIL: TECH.CONTROL.3@US.AF.MIL ALT: CIRCUIT ACTIONS D271-6959,
C402-294-6959
EMAIL: CIRCUIT.ACTIONS8@US.AF.MIL ORG EMAIL: CIRCUIT.ACTIONS8@US.AF.MIL
Location B, UNIQUE INSTALLATION FACTORS change from:
AMPLIFYING INFO:
A. VENDOR IS RESPONSIBLE FOR INSTALLATION AND MAINTENANCE OF THE SERVICE FROM THE LINE SIDE OF
THE DISA IE1 PROVIDED FIBER TERMINATING PATCH PANEL INSTALLED IN THE CISCO ASR-9010 ROUTER SUITE
(UJEWSCO030) BLDG 1575, ROOM C1B TO THE DROP SIDE OF THE COMMERCIAL FIBER POINT OF PRESENCE FIBER
DISTRIBUTION PANEL BLDG 1575, ROOM C1B USING SINGLE MODE FIBER. COORDINATE TYPE CONNECTORS TO BE
USED FOR TERMINATION TO THE DISA PROVIDED PATCH PANEL.
B. VENDOR MUST COORDINATE WITH GOVERNMENT SITE PERSONNEL TO CONDUCT WALK THROUGH SITE
SURVEYS FOR EXACT CABLE FT. FROM THE DISA PROVIDED FIBER TERMINATING PATCH PANEL INSTALLED IN THE
CISCO ASR-9010 ROUTER SUITE BLDG 1575, ROOM C1B TO THE COMMERCIAL FIBER POINT OF PRESENCE BLDG
1575, ROOM C1B.
C. VENDOR MUST PROVIDE FIBER STRANDS FROM THE DISA PROVIDED FIBER PATCH PANEL INSTALLED IN THE
CISCO ASR-9010 ROUTER TO THE COMMERCIAL DEMARC LOCATION WITHOUT SPLICING AND OR USE OF
CONNECTORS TO CONNECT 2 OR MORE FIBER STRANDS MEANING THE FIBER CANNOT BE BROKEN IN THE
MIDDLE AND MUST BE CONTINUOUS.
D. VENDOR MUST SCHEDULE/COORDINATE WITH THE POC'S LISTED ON THIS ORDER 72 HOURS IN ADVANCE PRIOR
TO SITE SURVEYS OR INSTALLATIONS.
(1) FIBER CABLE X-CONNECT, IN-HOUSE, INSIDE WIRE, SINGLE-MODE, 1310NM, TELCO
(2) TELCO MULTIPLEX (COMMERCIAL FIBER POINT OF PRESENCE) COMMERCIAL CARRIER SYSTEM (LOCAL
EXCHANGE CARRIER)
AMPLIFYING INFO:
A. VENDOR IS RESPONSIBLE FOR INSTALLATION AND MAINTENANCE OF THE SERVICE FROM THE LINE SIDE OF
THE DISA IE1 PROVIDED FIBER TERMINATING PATCH PANEL INSTALLED IN THE ASR 9010 ROUTER SUITE
(UJEWOFF040) BLDG 301D, ROOM 53 TO THE DROP SIDE OF THE COMMERCIAL FIBER POINT OF PRESENCE FIBER
DISTRIBUTION PANEL BLDG 301D, ROOM 134 USING SINGLE MODE FIBER. COORDINATE TYPE CONNECTORS TO BE
USED FOR TERMINATION TO THE DISA PROVIDED PATCH PANEL.
B. VENDOR MUST COORDINATE WITH GOVERNMENT SITE PERSONNEL TO CONDUCT WALK THROUGH SITE
SURVEYS FOR EXACT CABLE FT. FROM THE DISA PROVIDED FIBER TERMINATING PATCH PANEL INSTALLED IN THE
ASR 9010 ROUTER SUITE BLDG 301D, ROOM 53 TO THE COMMERCIAL FIBER POINT OF PRESENCE BLDG 301D, ROOM 134.
C. VENDOR MUST PROVIDE FIBER STRANDS FROM THE DISA PROVIDED FIBER PATCH PANEL INSTALLED IN THE
ASR 9010 ROUTER TO THE COMMERCIAL DEMARC LOCATION WITHOUT SPLICING AND OR USE OF CONNECTORS
TO CONNECT 2 OR MORE FIBER STRANDS MEANING THE FIBER CANNOT BE BROKEN IN THE MIDDLE AND MUST BE
CONTINUOUS.
D. VENDOR MUST SCHEDULE/COORDINATE WITH THE POC'S LISTED ON THIS ORDER 72 HOURS IN ADVANCE PRIOR
TO SITE SURVEYS OR INSTALLATIONS. 2 OR MORE FIBER STRANDS MEANING THE FIBER CANNOT BE BROKEN IN
THE MIDDLE AND MUST BE CONTINUOUS. VENDOR MUST SCHEDULE/COORDINATE WITH THE POC'S LISTED ON
THIS ORDER 72 HOURS IN ADVANCE PRIOR TO SITE SURVEYS OR INSTALLATIONS.
Location B, CONTACT change from:
PRI: STEPHEN CLABAUGH
D490-0421
C314-260-0421
EMAIL: STEPHEN.G.CLABAUGH.CIV@MAIL.MIL
ALT: JASON NOLEN
D490-0431
C314-260-0431
EMAIL: JASON.L.NOLEN2.CIV@MAIL.MIL
ORG EMAIL: DISA.STLOUIS.ESD.MBX.NODE-SITE-COORDINATOR@MAIL.MIL
To:
PRI: SHIFT SUPERVISOR D271-3210 C402-294-3210
EMAIL: TECH.CONTROL.3@US.AF.MIL ALT: CIRCUIT ACTIONS D271-6959,
C402-294-6959
EMAIL: CIRCUIT.ACTIONS8@US.AF.MIL ORG EMAIL: CIRCUIT.ACTIONS8@US.AF.MIL
Location B, NPA/NXX change from:
314/260
402/232