IQO INQUIRY
FM: PL8211
TO: Contractors
DATE (MM/DD/YYYY): 5/23/2018
SUBJECT: HC101318QA680-0001 Amend: 0001
A. TYPE ACTION: ADMIN AMEND
1. PURPOSE: THE PURPOSE OF THIS AMENDMENT IS TO:
1. CHANGE THE PROPOSAL DUE DATE TO 15 JUN 18 AT 4:00 P.M. (CST).
2. CHANGE SERVICE DATE TO 15 OCT 18 SIP.
3. CLARIFY THE SERVICE DELIVERY POINT (SDP) FOR THE TRAVIS AFB END IS 136 DIXON
AVENUE, BUILDING 902, SERVER ROOM, TRAVIS AFB, CA 94535, WITH DEMARK FOR SAME
AS 631 E. STREET, BUILDING 54, SWITCH ROOM, TRAVIS AFB, CA 94535.
4. CLARIFY THE SDP FOR THE VANDENBERG AFB END IS 723 NEBRASKA AVENUE, BUILDING
10525, ROOM 30, VANDENBERG AFB, CA 93437, WITH DEMARK FOR SAME AS 41 LAKE
CANYON ROAD, BUILDING 15501L, SWITCH ROOM, VANDENBERG AFB, CA 93437.
5. UPDATE EQUIPMENT INFORMATION AND UNIQUE INSTALLATION FACTORS FOR BOTH
LOCATIONS.
RECAP
SUBMIT A QUOTE TO PROVIDE, INSTALL, AND MAINTAIN THE NEW LEASE OF A 10 GIGABIT
ETHERNET BACKBONE CIRCUIT BETWEEN THE J-PE ROUTER (UJEWTRA040) IN BLDG 902,
RM SERVER, 136 DIXON AVE, TRAVIS AFB, CA AND J-PE ROUTER (UJEWVAN040) IN BLDG
10525, RM 30, 723 NEBRASKA AVENUE, VANDENBERG AFB, CA.. **SEE UNIQUE INSTALL
FACTORS**
A. ESTABLISH TSP.
B. THE COMMITTED INFORMATION RATE (CIR)(10GBE) WILL REQUIRE VENDOR TO DELIVER
10GB ETHERNET LAN PHY INTERFACE AT THE DROP SIDE OF THE COMMERCIAL DEMARC'S
AT THE "A" AND "Z" LOCATIONS.
C. CONTRACTORS SHALL MEET RTD OF 10 MILLISECONDS
2. EACH CONTRACTOR IS RESPONSIBLE FOR READING AND COMPLYING WITH ALL
TECHNICAL ASPECTS OF THIS SOLICITATION, TO INCLUDE READING AND AGREEING
WITH THE STANDARD PROVISIONS, ATTACHMENTS LISTING SPECIFIC TECHNICAL
REQUIREMENTS, PRICE QUOTE REQUIREMENTS, AND REQUESTED SERVICE DATE.
FAILURE TO READ AND ADHERE TO ANY PORTION OF THE INQUIRY SHALL RENDER THE
QUOTE NON-COMPLIANT AND RESULT IN IT BEING EXCLUDED FROM EVALUATION AND
AWARD.
3. THE SERVICE DATE TO BE MET IS: 15 OCT 18 (SIP). THE GOVERNMENT ASSUMES
THAT CONTRACTORS HAVE CONSIDERED ALL ISSUES THAT MAY IMPACT THE SERVICE
DATE. THE GOVERNMENT MAY CANCEL, TERMINATE, OR REQUEST CONSIDERATION
HC101318QA680-0001
IAW STANDARD PROVISION 42 FOR FAILURE TO MEET CONTRACTUAL SERVICE DATE OR
COMPLY WITH ANY CONTRACT TERMS OR CONDITIONS.
4. CONTRACTORS SHALL SUBMIT QUOTES IAW STANDARD PROVISION 04. QUOTES
SHALL INCLUDE SUFFICIENT DETAIL FOR EFFECTIVE EVALUATION AND SHOULD
NOT SIMPLY REPHRASE OR RESTATE THE GOVERNMENT REQUIREMENTS. RATHER,
THEY MUST PROVIDE CONVINCING RATIONALE TO ADDRESS HOW THE CONTRACTOR
INTENDS TO MEET THE REQUIREMENT. IN RESPONSE TO THIS SOLICITATION, NO
TERMS OR CONDITIONS PLACED UPON THE GOVERNMENT, NOR ASSUMPTIONS WILL BE
ACCEPTED. CONTRACTORS ARE ENCOURAGED TO SUBMIT QUESTIONS AND REQUEST
CLARIFICATIONS OF THE REQUIREMENT (S) BEFORE SUBMITTING QUOTES. QUESTIONS
SHALL BE SUBMITTED TO CONTRACT SPECIALIST AND CONTRACTING OFFICER DURING
THE SOLICITATION PHASE ONLY, AND RESPONSES FOR ALL INTERESTED PARTIES WILL BE
POSTED TO FEDBIZOPPS. QUOTES MUST BE UPLOADED TO IDEAS. IN THE EVENT IDEAS IS
UNAVAILABLE OR QUOTES FAIL TO UPLOAD, QUOTES MAY BE SENT TO THE FOLLOWING
MAILBOX: DISA.SCOTT.DITCO.MBX.VENDOR-QUOTES@MAIL.MIL
QUOTES MUST BE UPLOADED TO IDEAS. IN THE EVENT IDEAS IS UNAVAILABLE OR
QUOTES FAIL TO UPLOAD, QUOTES MAY BE SENT TO THE FOLLOWING MAILBOX:
disa.scott.ditco.mbx.pl8211@mail.mil
5. THIS REQUIREMENT MUST BE WORKED IN CONJUNCTION WITH SOLICITATION
HC101318QA657/TSR RU20FEB185779 AND MUST BE ENGINEERED AND PROVISIONED
TOTALLY DIVERSE END TO END FROM THE GOVERNMENT SERVICE DELIVERY POINTS
(SDP) FROM TSR RU20FEB185779; MEANING THE PHYSICAL PATHS ARE TOTALLY
SEPARATE INCLUDING MAN HOLES, CONDUIT, CENTRAL OFFICE LOCATIONS, AND FIBER
BUILDS. ADDITIONALLY AS A MINIMUM MUST HAVE 50 METERS PHYSICAL SEPARATION
FROM TSR RU20FEB185779.
6. CONTRACTOR SHALL PROVIDE COLOR POWERPOINT DRAWINGS SHOWING THE ROUTES
FROM THE COMMERCIAL DEMARKS TO THE SUPPORTING CENTRAL OFFICES AND/OR
WIRING CENTERS, ENSURING THE PHYSICAL END TO END DIVERSITY REQUIREMENTS ARE
BEING MET. DRAWINGS MUST INCLUDE SEPARATION DISTANCES, TOTAL FIBER MILES
AND ROUND TRIP DELAY BASED ON ACTUAL DISTANCE IN MILES. REFER TO STANDARD
PROVISION 39 FOR SPECIFIC DOCUMENTATION REQUIREMENTS. SAMPLE DRAWINGS ARE
INCLUDED THE ATTACHMENTS.
7. PRE AWARD SITE SURVEYS ARE AUTHORIZED (AT CONTRACTOR EXPENSE) WITH LOCAL
POCS AT EACH GOVERNMENT SITE. IT IS HIGHLY RECOMMENDED THAT AT A MINIMUM,
CONTRACTORS CONDUCT PHONE SURVEYS TO ADEQUATELY ASSESS THE MAGNITUDE OF
THE WORK TO BE PERFORMED IN DETERMINING THEIR PRICE STRATEGY.
M. ADDITIONAL INFORMATION:
3. TSR NUMBER: RU20FEB185780
4. CCSD: XXXXBBNE
Z. DITCO CONTACT:
Christopher OConnor
618-229-9712 christopher.t.oconnor2.civ@mail.mil
Paul A. Heard
DITCO Contracting Officer
Unless otherwise specified, all other terms and conditions are unchanged.
Paragraph E.SERVICE DATE change from:
Sep 14, 2018
To:
Oct 15, 2018
Paragraph V.QUOTE DUE DATE AND TIME change from:
Apr 11, 2018 4:00:00 PM CDT
Jun 15, 2018 4:00:00 PM CDT
Location A, LOCATION OF TERMINATION A change from:
ADDRESS: BLDG 15501L41 LAKE CANYON ROADVANDENBERG AFB, CA 93437-5206
ROOM: SWITCH ROOM; 1 FL
LOCATION: VNDNBAFB
ADDRESS: BLDG 902136 DIXON AVENUETRAVIS AFB, CA 94535
ROOM: SERVER ROOM
LOCATION: TRAVSAFB
Location A, DEMARK change from:
BLDG 10525
Room 30
723 Nebraska Avenue
Vandenberg AFB, CA 93437
To:
BLDG 54
SWITCH ROOM
631 E. STREET
TRAVIS AFB, CA 94535
Location A, UNIQUE INSTALLATION FACTORS change from:
(1) FIBER CABLE X-CONNECT, IN-HOUSE, INSIDE WIRE SINGLE-MODE, 1310NM, TELCO
(2) TELCO MULTIPLEX (COMMERCIAL FIBER POINT OF PRESENCE) COMMERCIAL CARRIER SYSTEM (LOCAL
EXCHANGE CARRIER)
AMPLIFYING INFO:
A. VENDOR IS RESPONSIBLE FOR INSTALLATION AND MAINTENANCE OF THE SERVICE FROM THE LINE SIDE OF
THE DISA IE1 PROVIDED FIBER TERMINATING PATCH PANEL INSTALLED IN THE CISCO ASR-9010 ROUTER SUITE
(UJEWVAN040) BLDG 10525, ROOM 30 TO THE DROP SIDE OF THE COMMERCIAL FIBER POINT OF PRESENCE FIBER
DISTRIBUTION PANEL BLDG 15501L, ROOM TELCO USING SINGLE MODE FIBER. COORDINATE TYPE CONNECTORS
TO BE USED FOR TERMINATION TO THE DISA PROVIDED PATCH PANEL.
B. VENDOR MUST COORDINATE WITH GOVERNMENT SITE PERSONNEL TO CONDUCT WALK THROUGH SITE
SURVEYS FOR EXACT CABLE FT. FROM THE DISA PROVIDED FIBER TERMINATING PATCH PANEL INSTALLED IN THE
CISCO ASR-9010 ROUTER SUITE BLDG 10525, RM 30 TO THE COMMERCIAL FIBER POINT OF PRESENCE BLDG
15501L, ROOM TELCO.
C. VENDOR MUST PROVIDE FIBER STRANDS FROM THE DISA PROVIDED FIBER PATCH PANEL INSTALLED IN THE
CISCO ASR-9010 ROUTER TO THE COMMERCIAL DEMARC LOCATION WITHOUT SPLICING AND OR USE OF
CONNECTORS TO CONNECT 2 OR MORE FIBER STRANDS MEANING THE FIBER CANNOT BE BROKEN IN THE MIDDLE
AND MUST BE CONTINUOUS.
D. VENDOR MUST SCHEDULE/COORDINATE WITH THE POC'S LISTED ON THIS ORDER 72 HOURS IN ADVANCE
PRIOR TO SITE SURVEYS OR INSTALLATIONS.
To:
(1) FIBER CABLE X-CONNECT, IN-HOUSE, INSIDE WIRE,
SINGLE-MODE, 1310NM, TELCO
(2) TELCO MULTIPLEX (COMMERCIAL FIBER POINT OF PRESENCE) COMMERCIAL CARRIER SYSTEM (LOCAL
EXCHANGE CARRIER)
(3) JUNIPER MX-240 ROUTER (GFE)(DISA IE1 PROVIDED) NODE ID:
UJEWTRA040
(4) OPTICAL INTERFACE CARD (GFE)(DISA IE1 PROVIDED)
RACK/SHELF/SLOT/PORT - TE-0/2/0/0
(5) IP ADDRESS 33.20.18.93/30
AMPLIFYING INFO:
A. VENDOR IS RESPONSIBLE FOR INSTALLATION AND MAINTENANCE OF THE SERVICE FROM THE LINE SIDE OF
THE DISA IE1 PROVIDED FIBER TERMINATING PATCH PANEL INSTALLED IN THE JUNIPER MX-240 ROUTER SUITE
(UJEWTRA040) BLDG 902, ROOM SERVER TO THE DROP SIDE OF THE COMMERCIAL FIBER POINT OF PRESENCE
FIBER DISTRIBUTION PANEL BLDG 54, ROOM SWITCH USING SINGLE MODE FIBER. COORDINATE TYPE
CONNECTORS TO BE USED FOR TERMINATION TO THE DISA PROVIDED PATCH PANEL.
B. VENDOR MUST COORDINATE WITH GOVERNMENT SITE PERSONNEL TO CONDUCT WALK THROUGH SITE
SURVEYS FOR EXACT CABLE FT. FROM THE DISA PROVIDED FIBER TERMINATING PATCH PANEL INSTALLED IN THE
JUNIPER MX-240 ROUTER SUITE BLDG 902, ROOM SERVER TO THE COMMERCIAL FIBER POINT OF PRESENCE
BLDG 54, ROOM SWITCH
C. VENDOR MUST PROVIDE FIBER STRANDS FROM THE DISA PROVIDED FIBER PATCH PANEL INSTALLED IN THE
JUNIPER MX-240 ROUTER TO THE COMMERCIAL DEMARC LOCATION WITHOUT SPLICING AND OR USE OF
CONNECTORS TO CONNECT 2 OR MORE FIBER STRANDS MEANING THE FIBER CANNOT BE BROKEN IN THE MIDDLE
AND MUST BE CONTINUOUS.
D. VENDOR MUST SCHEDULE/COORDINATE WITH THE POC’S LISTED ON THIS ORDER 72 HOURS IN ADVANCE
PRIOR TO SITE SURVEYS OR INSTALLATIONS.
E. DISA IE4 IS RESPONSIBLE FOR INSTALLATION AND GSM-O FOR MAINTENANCE OF JUNIPER MX-240 ROUTER, OPTICAL INTERFACE CARD BLDG 902, ROOM SERVER.
F. DISA IE4 IS RESPONSIBLE FOR INSTALLATION AND GSM-O FOR SERVICE FROM THE INTERFACE CARD
INSTALLED IN THE ROUTER TO THE DROP SIDE OF THE DISA IE1 PROVIDED FIBER TERMINATING PATCH PANEL
INSTALLED IN THE JUNIPER MX-240 SUITE, USING SINGLE-MODE FIBER JUMPERS. COORDINATE TYPE OF
CONNECTORS.
G. VENDOR IS RESPONSIBLE FOR INSTALLATION AND MAINTENANCE OF THE SERVICE FROM THE LINE SIDE OF
THE DISA IE1 PROVIDED FIBER TERMINATING PATCH PANEL INSTALLED IN THE JUNIPER MX-240 ROUTER SUITE
(UJEWTRA040) BLDG 902, ROOM SERVER TO THE DROP SIDE OF THE COMMERCIAL FIBER POINT OF PRESENCE
FIBER DISTRIBUTION PANEL BLDG 54, ROOM SWITCH USING SINGLE MODE FIBER. COORDINATE TYPE
CONNECTORS TO BE USED FOR TERMINATION TO THE DISA PROVIDED PATCH PANEL.
H. THE CIRCUIT MUST BE TAGGED WITH THE LOCAL CIRCUIT ID AND LONG-HAUL CIRCUIT NO. AT THE LINE SIDE OF
THE DISA PROVIDED FIBER TERMINATING PATCH.
Location A, CONTACT change from:
(PMRY POC) MS INGRID M MICHELS
(UNCLASS ORG) LONG.HAUL@US.AF.MIL
(UNCLASS USER) INGRID.MICHELS.3@US.AF.MIL
(CMCL) 805-606-5434
(DSN) 276-5434
(ALT POC) MR. STEVEN R BOYLES
(UNCLASS ORG) LONG.HAUL@US.AF.MIL
(UNCLASS USER) STEVE.BOYLES@US.AF.MIL
(CMCL) 805-605-5108
(DSN) 257-5108
To:
(PMRY POC) KENNETH P PRITCHETT
(UNCLASS ORG) 60CS.CIRCUITACTIONS@US.AF.MIL
(UNCLASS USER) KENNETH.PRITCHETT@US.AF.MIL
(CMCL) 707-424-0363
(DSN) 837-0363
(ALT POC) FRANCIUS CHERY
(UNCLASS ORG) 60CS.CIRCUITACTIONS@US.AF.MIL
(UNCLASS USER) FRANCIUS.CHERY@US.AF.MIL
(CMCL) 707-424-0005
(DSN) 837-0005
Location A, INTERFACE change from:
INTERFACE: ELECTRICAL: 10GBASE-LR; PHYSICAL: SC;; (PHYSICAL) SC; (ELECTRICAL) 10GBASE-LR
ELECTRICAL: 10GBASE-LR; PHYSICAL: SC;; (PHYSICAL) SC; (ELECTRICAL) 10GBASE-LR
Location A, INSIDE WIRE INSTALLATION / MAINTENANCE REQUIRED change from:
CPIWI-YES/ CPIWM-YES
To:
CPIWI-YES/CPIWM-YES
Location A, NPA/NXX change from:
805/606
707/424
Location A, TERMINAL EQUIPMENT change from:
Commercial Fiber Point of Presence
Commercial Fiber Point of Presence; JUNIPER IPT-PE MX240 (UJEWTRA040)
Location B, LOCATION OF TERMINATION B change from:
ADDRESS: BLDG 54631 E STREETTRAVIS AFB, CA 94535
ROOM: SWITCH ROOM
LOCATION: TRAVSAFB
ADDRESS: BLDG 10525723 NEBRASKA AVENUEVANDENBERG AFB, CA 93437-6120
ROOM: ROOM 30; 1 FL
LOCATION: VNDNBAFB
Location B, DEMARK change from:
BLDG 902
Rm Server
136 Dixon Avenue
Travis AFB, CA 94535
BUILDING 15501L
SWITCH ROOM
41 LAKE CANYON ROAD
VANDENBERG AFB, CA 93437-5206
Location B, UNIQUE INSTALLATION FACTORS change from:
(1) FIBER CABLE X-CONNECT, IN-HOUSE, INSIDE WIRE,
SINGLE-MODE, 1310NM, TELCO
(2) TELCO MULTIPLEX (COMMERCIAL FIBER POINT OF PRESENCE) COMMERCIAL CARRIER SYSTEM (LOCAL
EXCHANGE CARRIER)
AMPLIFYING INFO:
A. VENDOR IS RESPONSIBLE FOR INSTALLATION AND MAINTENANCE OF THE SERVICE FROM THE LINE SIDE OF
THE DISA IE1 PROVIDED FIBER TERMINATING PATCH PANEL INSTALLED IN THE JUNIPER MX-240 ROUTER SUITE
(UJEWTRA040) BLDG 902, ROOM SERVER TO THE DROP SIDE OF THE COMMERCIAL FIBER POINT OF PRESENCE
FIBER DISTRIBUTION PANEL BLDG 54, ROOM SWITCH USING SINGLE MODE FIBER. COORDINATE TYPE
CONNECTORS TO BE USED FOR TERMINATION TO THE DISA PROVIDED PATCH PANEL.
B. VENDOR MUST COORDINATE WITH GOVERNMENT SITE PERSONNEL TO CONDUCT WALK THROUGH SITE
SURVEYS FOR EXACT CABLE FT. FROM THE DISA PROVIDED FIBER TERMINATING PATCH PANEL INSTALLED IN THE
JUNIPER MX-240 ROUTER SUITE BLDG 902, ROOM SERVER TO THE COMMERCIAL FIBER POINT OF PRESENCE
BLDG 54, ROOM SWITCH
C. VENDOR MUST PROVIDE FIBER STRANDS FROM THE DISA PROVIDED FIBER PATCH PANEL INSTALLED IN THE
JUNIPER MX-240 ROUTER TO THE COMMERCIAL DEMARC LOCATION WITHOUT SPLICING AND OR USE OF
CONNECTORS TO CONNECT 2 OR MORE FIBER STRANDS MEANING THE FIBER CANNOT BE BROKEN IN THE MIDDLE
AND MUST BE CONTINUOUS.
D. VENDOR MUST SCHEDULE/COORDINATE WITH THE POC’S LISTED ON THIS ORDER 72 HOURS IN ADVANCE
PRIOR TO SITE SURVEYS OR INSTALLATIONS.
To:
(1) FIBER CABLE X-CONNECT, IN-HOUSE, INSIDE WIRE SINGLE-MODE, 1310NM, TELCO
(2) TELCO MULTIPLEX (COMMERCIAL FIBER POINT OF PRESENCE) COMMERCIAL CARRIER SYSTEM (LOCAL
EXCHANGE CARRIER)
(3) CISCO ASR-9010 ROUTER (GFE)(DISA IE1 PROVIDED) NODE ID: UJEWVAN040
(4) OPTICAL INTERFACE CARD (GFE)(DISA IE1 PROVIDED)RACK/SHELF/SLOT/PORT - TE-0/3/0/1
(5) IP ADDRESS 33.20.18.94/30
AMPLIFYING INFO:
A. VENDOR IS RESPONSIBLE FOR INSTALLATION AND MAINTENANCE OF THE SERVICE FROM THE LINE SIDE OF
THE DISA IE1 PROVIDED FIBER TERMINATING PATCH PANEL INSTALLED IN THE CISCO ASR-9010 ROUTER SUITE
(UJEWVAN040) BLDG 10525, ROOM 30 TO THE DROP SIDE OF THE COMMERCIAL FIBER POINT OF PRESENCE FIBER
DISTRIBUTION PANEL BLDG 15501L, ROOM TELCO USING SINGLE MODE FIBER. COORDINATE TYPE CONNECTORS
TO BE USED FOR TERMINATION TO THE DISA PROVIDED PATCH PANEL.
B. VENDOR MUST COORDINATE WITH GOVERNMENT SITE PERSONNEL TO CONDUCT WALK THROUGH SITE
SURVEYS FOR EXACT CABLE FT. FROM THE DISA PROVIDED FIBER TERMINATING PATCH PANEL INSTALLED IN THE
CISCO ASR-9010 ROUTER SUITE BLDG 10525, RM 30 TO THE COMMERCIAL FIBER POINT OF PRESENCE BLDG
15501L, ROOM TELCO.
C. VENDOR MUST PROVIDE FIBER STRANDS FROM THE DISA PROVIDED FIBER PATCH PANEL INSTALLED IN THE
CISCO ASR-9010 ROUTER TO THE COMMERCIAL DEMARC LOCATION WITHOUT SPLICING AND OR USE OF
CONNECTORS TO CONNECT 2 OR MORE FIBER STRANDS MEANING THE FIBER CANNOT BE BROKEN IN THE MIDDLE
AND MUST BE CONTINUOUS.
D. VENDOR MUST SCHEDULE/COORDINATE WITH THE POC'S LISTED ON THIS ORDER 72 HOURS IN ADVANCE
PRIOR TO SITE SURVEYS OR INSTALLATIONS.
E. DISA IE4 IS RESPONSIBLE FOR INSTALLATION AND GSM-O FOR
MAINTENANCE OF THE CISCO ASR-9010 ROUTER, OPTICAL INTERFACE CARD BLDG 10525, RM 30.
F. DISA IE4 IS RESPONSIBLE FOR INSTALLATION AND GSM-O FOR SERVICE FROM THE INTERFACE CARD
INSTALLED IN THE ROUTER TO THE DROP SIDE OF THE DISA IE1 PROVIDED FIBER TERMINATING PATCH PANEL
INSTALLED IN THE CISCO ASR-9010 SUITE, USING SINGLE-MODE FIBER JUMPERS. COORDINATE TYPE OF
CONNECTORS.
G. VENDOR IS RESPONSIBLE FOR INSTALLATION AND MAINTENANCE OF THE SERVICE FROM THE LINE SIDE OF
THE DISA IE1 PROVIDED FIBER TERMINATING PATCH PANEL INSTALLED IN THE CISCO ASR-9010 ROUTER SUITE
(UJEWVAN040) BLDG 10525, RM 30 TO THE DROP SIDE OF THE COMMERCIAL FIBER POINT OF PRESENCE FIBER
DISTRIBUTION PANEL BLDG 15501L, ROOM TELCO USING SINGLE MODE FIBER. COORDINATE TYPE CONNECTORS
TO BE USED FOR TERMINATION TO THE DISA PROVIDED PATCH PANEL.
H. THE CIRCUIT MUST BE TAGGED WITH THE LOCAL CIRCUIT ID AND LONG HAUL CIRCUIT NO. AT THE LINE SIDE OF
THE DISA PROVIDED FIBER TERMINATING PATCH PANEL BLDG 10525, ROOM 30 AND AT THE DROP SIDE OF THE
VENDOR'S FIBER DISTRIBUTION PANEL INSTALLED IN THEIR COMMERCIAL SUITE. ADDITIONALLY, VENDOR MUST
SHOW SITE PERSONNEL LISTED ON THIS ORDER THE EXACT TERMINATION POINT WHEN SERVICE
IS COMPLETE.
Location B, CONTACT change from:
(PMRY POC) KENNETH P PRITCHETT
(UNCLASS ORG) 60CS.CIRCUITACTIONS@US.AF.MIL
(UNCLASS USER) KENNETH.PRITCHETT@US.AF.MIL
(CMCL) 707-424-0363
(DSN) 837-0363
(ALT POC) FRANCIUS CHERY
(UNCLASS ORG) 60CS.CIRCUITACTIONS@US.AF.MIL
(UNCLASS USER) FRANCIUS.CHERY@US.AF.MIL
(CMCL) 707-424-0005
(DSN) 837-0005
To:
(PMRY POC) MS INGRID M MICHELS
(UNCLASS ORG) LONG.HAUL@US.AF.MIL
(UNCLASS USER) INGRID.MICHELS.3@US.AF.MIL
(CMCL) 805-606-5434
(DSN) 276-5434
(ALT POC) MR. STEVEN R BOYLES
(UNCLASS ORG) LONG.HAUL@US.AF.MIL
(UNCLASS USER) STEVE.BOYLES@US.AF.MIL
(CMCL) 805-605-5108
(DSN) 257-5108
Location B, INTERFACE change from:
ELECTRICAL: 10GBASE-LR; PHYSICAL: SC;; (PHYSICAL) SC; (ELECTRICAL) 10GBASE-LR
To:
INTERFACE: ELECTRICAL: 10GBASE-LR; PHYSICAL: SC;; (PHYSICAL) SC; (ELECTRICAL) 10GBASE-LR
Location B, INSIDE WIRE INSTALLATION / MAINTENANCE REQUIRED change from:
CPIWI-YES/CPIWM-YES
CPIWI-YES/ CPIWM-YES
Location B, NPA/NXX change from:
707/424
805/605
Location B, TERMINAL EQUIPMENT change from:
Commercial Fiber Point of Presence
Commercial Fiber Point of Presence; CISCO ASR 9010 (UJEWVAN040)