IQO INQUIRY
FM: PL8211
TO: Contractors
DATE (MM/DD/YYYY): 5/3/2018
SUBJECT: HC101318QA629-0001 Amend: 0001
A. TYPE ACTION: AMEND
1. PURPOSE: ***AMEND 0001 IS ISSUED TO CHANGE THE RTD REQUIREMENTS TO LESS
THAN OR EQUAL TO 13 M/S; PROPOSAL DUE DATE TO 10 MAY 18; AND SERVICE DATE TO 10
SEP 18. ALL ELSE REMAINS THE SAME.***
SUBMIT A QUOTE TO PROVIDE, INSTALL, AND MAINTAIN A 1GBE (GIGABIT ETHERNET)
BETWEEN BLDG 110, RM 203, 1400 32ND AVENUE NORTH, FARGO, ND AND BLDG 501, RM
U127, 901 SAC BLVD, OFFUTT AFB, NE.
ESTABLISH TSP.
TELECOMM PROVIDER MUST PROVIDE TOTAL FIBER MILES AND ROUND-TRIP DELAY (RTD)
FROM THE CUSTOMER "A" LOCATION TO THE CUSTOMER "Z" LOCATION.
RTD SHALL BE MEASURED OVER THE 1GB WAVE CIRCUIT AND SHALL BE LESS THAN OR
EQUAL TO 13 MILLISECONDS.
COMPLETION REPORT REQUIRED.
SEE UNIQUE INSTALL FACTORS.
VENDORS MUST CLEARLY STATE IN QUOTES THEIR COMPLIANCE WITH GOVERNMENT
TESTING AND ACCEPTANCE REQUIREMENTS
2. EACH CONTRACTOR IS RESPONSIBLE FOR READING AND COMPLYING WITH ALL
TECHNICAL ASPECTS OF THIS SOLICITATION, TO INCLUDE READING AND AGREEING
WITH THE STANDARD PROVISIONS, ATTACHMENTS LISTING SPECIFIC TECHNICAL
REQUIREMENTS, PRICE QUOTE REQUIREMENTS, AND REQUESTED SERVICE DATE.
FAILURE TO READ AND ADHERE TO ANY PORTION OF THE INQUIRY SHALL RENDER THE
QUOTE NON-COMPLIANT AND RESULT IN IT BEING EXCLUDED FROM EVALUATION AND
AWARD.
3. THE SERVICE DATE TO BE MET IS: 10 SEP 18 (SIP). THE GOVERNMENT ASSUMES
THAT CONTRACTORS HAVE CONSIDERED ALL ISSUES THAT MAY IMPACT THE SERVICE
DATE. THE GOVERNMENT MAY CANCEL, TERMINATE, OR REQUEST CONSIDERATION
IAW STANDARD PROVISION 42 FOR FAILURE TO MEET CONTRACTUAL SERVICE DATE OR
COMPLY WITH ANY CONTRACT TERMS OR CONDITIONS.
4. CONTRACTORS SHALL SUBMIT QUOTES IAW STANDARD PROVISION 04. QUOTES
SHALL INCLUDE SUFFICIENT DETAIL FOR EFFECTIVE EVALUATION AND SHOULD
HC101318QA629-0001
NOT SIMPLY REPHRASE OR RESTATE THE GOVERNMENT REQUIREMENTS. RATHER,
THEY MUST PROVIDE CONVINCING RATIONALE TO ADDRESS HOW THE CONTRACTOR
INTENDS TO MEET THE REQUIREMENT. IN RESPONSE TO THIS SOLICITATION, NO
TERMS OR CONDITIONS PLACED UPON THE GOVERNMENT, NOR ASSUMPTIONS WILL BE
ACCEPTED. CONTRACTORS ARE ENCOURAGED TO SUBMIT QUESTIONS AND REQUEST
CLARIFICATIONS OF THE REQUIREMENT (S) BEFORE SUBMITTING QUOTES. QUESTIONS
SHALL BE SUBMITTED TO CONTRACT SPECIALIST AND CONTRACTING OFFICER DURING
THE SOLICITATION PHASE ONLY, AND RESPONSES FOR ALL INTERESTED PARTIES WILL BE
POSTED TO FEDBIZOPPS. QUOTES MUST BE UPLOADED TO IDEAS.
5. ETHERNET TESTING MUST BE COORDINATED WITH CUSTOMER ACCEPTANCE
AUTHORITY AT BOTH LOCATIONS BEFORE NOTICE OF COMPLETION IS SUBMITTED TO
DITCO.
FOR DISA ETHERNET REQUIREMENTS THE ACCEPTING AUTHORITY IS:
Michael Reeves - michael.b.reeves.ctr@mail.mil, 618-220-8973
Clarence Moore - clarence.s.moore.ctr@mail.mil, 618-220-9935
6. THIS REQUIREMENT MUST BE WORKED IN CONJUNCTION WITH SOLICITATION
HC101318QA628/TSR RU20FEB185764 AND MUST BE ENGINEERED AND PROVISIONED
TOTALLY DIVERSE END TO END FROM THE GOVERNMENT SERVICE DELIVERY POINTS
(SDP) FROM TSR RU20FEB185764; MEANING THE PHYSICAL PATHS ARE TOTALLY
SEPARATE INCLUDING MAN HOLES, CONDUIT, CENTRAL OFFICE LOCATIONS, AND FIBER
BUILDS. ADDITIONALLY AS A MINIMUM MUST HAVE 50 METERS PHYSICAL SEPARATION
FROM TSR RU20FEB185764.
7. CONTRACTOR SHALL PROVIDE COLOR POWERPOINT DRAWINGS SHOWING THE ROUTES
FROM THE COMMERCIAL DEMARKS TO THE SUPPORTING CENTRAL OFFICES AND/OR
WIRING CENTERS, ENSURING THE PHYSICAL END TO END DIVERSITY REQUIREMENTS ARE
BEING MET. DRAWINGS MUST INCLUDE SEPARATION DISTANCES, TOTAL FIBER MILES
AND ROUND TRIP DELAY BASED ON ACTUAL DISTANCE IN MILES. REFER TO STANDARD
PROVISION 39 FOR SPECIFIC DOCUMENTATION REQUIREMENTS. SAMPLE DRAWINGS ARE
INCLUDED THE ATTACHMENTS.
8. PRE AWARD SITE SURVEYS ARE AUTHORIZED (AT CONTRACTOR EXPENSE) WITH LOCAL
POCS AT EACH GOVERNMENT SITE. IT IS HIGHLY RECOMMENDED THAT AT A MINIMUM,
CONTRACTORS CONDUCT PHONE SURVEYS TO ADEQUATELY ASSESS THE MAGNITUDE OF
THE WORK TO BE PERFORMED IN DETERMINING THEIR PRICE STRATEGY.
9. CIRCUIT PARAMETERS:
(A) FIBER TERMINATION: FRAME FORMAT: 1.0GB ETHERNET (OPITCAL
HANDOFF-1000BASE-LX-SINGLE MODE FIBER), 802.3Z, 1310NM. "SC" CONNECTORS;
(B) COMMITTED INFORMATION RATE (CIR) - 1GB.
(C) 1.0GB ETHERNET FRAMING REQUIRED AT COMMERCIAL DEMARC AT THE AAND Z
LOCATIONS.
(D) ETHERNET FRAME SIZE WILL BE CONFIGURED TO SUPPORT MAXIMUM TRANSMISSION
UNIT (MTU) OF 9192 OCTETS (BYTES).
(E) NO NETWORK INTERFACE UNIT, DEDICATED PATH
(F) GFE CLOCKING: VENDOR ESFU (OR EQUIVALENT) NOT TO BE ENGINEERED INTO
CIRCUIT.
(G) TESTING CRITERIA: VENDOR MUST TEST THE CIRCUIT FOR 24 HOURS IAW ITU-T.Y.1564
BENCH MARKING CONFIGURATION AND PERFORMANCE OF ETHERNET SERVICE. NOTE-
ETHERNET FRAME SIZE DESIGNATOR 'H' (MTU) IS EQUAL TO 9192 BYTES.
(H) LINE MUST REMAIN FULLY OPERATIONAL AND AVAILABLE TO USERS 24 HOURS A DAY,
SEVEN DAYS PER WEEK, AT LEAST 99.5% OR BETTER.
(I) 1 HOUR RESPONSE TIME TO RESPOND TO CUSTOMER UPON RECIEPT OF TROUBLE.
(J) VENDOR REQUIRED TO HAVE CIRCUIT VISIBILITY TO ASSIST IN ANY CIRCUIT OUTAGES.
(K) VENDOR MUST HAVE A 24X7 NETWORK OPERATIONS CENTER.
(L) TELECOMM PROVIDER MUST MAINTAIN OPERATIONS, MAINTENANCE AND
ADMINISTRATION MONITORING OF ETHERNET CIRCUIT IAW ITU-T-Y.1731.
(M) THE COMMERCIAL CIRCUIT WILL BE ACCEPTED ON BEHALF OF THE GOVERNMENT BY
THE DISA GOC IP BACKBONE ENGINEERING AND IMPLEMENTATION GROUP, SCOTT AFB, IL.
(C) 618-220-8627 (D) 770-8627.
(N) VENDOR MUST PROVIDE:
1. THE LONG-HAUL CIRCUIT NO. AND LEC CKT ID'S AS APPLICABLE TO THE DISA IE161
PROGRAM OFFICE PRIOR TO TURN UP TO THE GOVERNMENT.
PRIMARY: KEN DIEFFENDERFER (301) 225-2416.
2. VENDOR WINNING AWARD IS RESPONSIBLE FOR INSTALLATION AND MAINTENANCE OF
1GBE SERVICE IAW THE UNIQUE INSTALLATION FACTORS.
3. INSIDE WIRING IS AUTHORIZED IAW THE UNIQUE INSTALLATION FACTORS.
M. ADDITIONAL INFORMATION:
3. TSR NUMBER: RU20FEB185765A
4. CCSD: XXXXBBPD
Z. DITCO CONTACT:
Robin Schuster
618-229-9649 robin.n.schuster.civ@mail.mil
Angelina Hutson
DITCO Contracting Officer
Unless otherwise specified, all other terms and conditions are unchanged.
Paragraph E.SERVICE DATE change from:
Aug 14, 2018
To:
Sep 10, 2018
Paragraph M.10.TESTING REQUIREMENTS change from:
MINIMUM TECHNICAL SPECIFICATIONS:
SPECIFIC FORMAT TO BE USED IS:
LINE RATE: 1.0709 GIGABITS/S, +- 100 PPM LINE CODE: OPTIC
ETHERNET FRAME: 9192 OCTETS (BYTES)
1. TEST AND ACCEPTANCE: FIBER OPTIC 1.0GB CIRCUITS SHALL PASS A FULLY DOCUMENTED SATISFACTORY 72
HOUR SOAK TEST BY DISA GOC AT SCOTT AFB, IL. PRIMARY: (C) 618-229-8691 (D) 779-8691;
2. TESTING PARAMETERS AND THRESHOLDS: THE FOLLOWING TESTING PARAMETERS SHALL BE MEASURED
DURING TEST AND ACCEPTANCE TESTING. ERROR PERFORMANCE SHALL BE MEASURED AND RECORDED OVER
THE DURATION OF THE CONTIGUOUS 24-HOUR TESTING INTERVAL AND SHALL BE MEASURED AND RECORDED
PER DEFINITION IN ITU-T-Y.1564.
3. ERROR PERFORMANCE: ERROR PERFORMANCE SHALL BE BETTER THAN THE FOLLOWING PARAMETER
THRESHOLDS TO BE ACCEPTABLE: AVAILABILITY SHALL BE GREATER THAN 99.5% OR BETTER. FRAME LOSS SHALL
BE EQUAL TO ZERO WHEN TESTING AT 1.0 GIGABIT HIGHEST FRAME RATE, AND SHALL MEET ITU-T-Y.1564
STANDARDS. JITTER SHALL BE LESS THAN 3 MSEC. DELAY SHALL BE BETTER THAN 10 MSEC
4. MEAN TIME TO LOSS OF BIT COUNT INTEGRITY (MTTLBCI) SHALL BE GREATER THAN 24 HOURS.
5. ROUND TRIP DELAY (RTD): RTD SHALL BE MEASURED OVER THE 1GB WAVE CIRCUIT AND SHALL BE LESS THAN
OR EQUAL TO 10 MILLISECONDS.
6. PROVIDER MUST CONDUCT A SATISFACTORY 24-HOUR TEST FROM THE DROP SIDE OF THEIR OR LOCAL
EXCHANGE CARRIERS FDP INSTALLED IN THEIR EQUIPMENT SUITE AT THE "A" LOCATION TO THE GOVERNMENT'S
SDP AT THE "Z" LOCATION AND MUST INCLUDE THE EXTENSION BETWEEN THE COMMERCIAL DEMARC AND THE
GOVERNMENT'S SDP AT THE "Z" LOCATION. VENDOR MUST ENSURE A TEST SET IS PLACED AT THE DROP SIDE OF
TELECOMM PROVIDER'S OR LOCAL ACCESS PROVIDERS FDP AS APPLICABLE AT THE "A" LOCATION AND A
SECOND TEST SET AT THE END OF THE FIBER JUMPERS TO BE USED FOR TERMINATION TO THE GOVERNMENT'S
SDP AT THE "Z" LOCATION. TESTING MUST BE SATISFACTORY PRIOR TO TURN OVER TO THE GOVERNMENT FOR
ACCEPTANCE TESTING.
7. TESTING CRITERIA: VENDOR MUST TEST THE CIRCUIT FOR 24 HOURS IAW ITU-T.Y.1564 BENCH MARKING
CONFIGURATION AND PERFORMANCE OF ETHERNET SERVICE. NOTE-ETHERNET FRAME SIZE DESIGNATOR 'H'
(MTU) IS EQUAL TO 9192 BYTES.
8. ALL EQUIPMENT AND CIRCUIT PROBLEMS WILL BE REPORTED BY PHONE TO THE DISA GOC IP BACKBONE
ENGINEERING AND IMPLEMENTATION GROUP, SCOTT AFB, IL. PRIMARY: (C) 618-220-9950, (D) 770-9950 TOLL FREE:
855-868-9950
9. DD FORM 1368 WILL BE SUBMITTED ON THIS TRUNK IAW DISAC-DITCO 350-135-1 BY RNSOC, SCOTT AFB, IL.
GUIDANCE ON SUBMISSION IS AVAILABLE AT <HTTP://WWW.DITCO.DISA.MIL /ASP/PUBLICATIONS.ASP> CLICK ON
"DISA-DITCO CIRCULAR, 350-135-1, DEFENSE COMMERCIAL COMMUNICATIONS ACQUISITION PROCEDURES."
To:
MINIMUM TECHNICAL SPECIFICATIONS:
SPECIFIC FORMAT TO BE USED IS:
LINE RATE: 1.0709 GIGABITS/S, +- 100 PPM LINE CODE: OPTIC
ETHERNET FRAME: 9192 OCTETS (BYTES)
1. TEST AND ACCEPTANCE: FIBER OPTIC 1.0GB CIRCUITS SHALL PASS A FULLY DOCUMENTED SATISFACTORY 72
HOUR SOAK TEST BY DISA GOC AT SCOTT AFB, IL. PRIMARY: (C) 618-229-8691 (D) 779-8691;
2. TESTING PARAMETERS AND THRESHOLDS: THE FOLLOWING TESTING PARAMETERS SHALL BE MEASURED
DURING TEST AND ACCEPTANCE TESTING. ERROR PERFORMANCE SHALL BE MEASURED AND RECORDED OVER
THE DURATION OF THE CONTIGUOUS 24-HOUR TESTING INTERVAL AND SHALL BE MEASURED AND RECORDED
PER DEFINITION IN ITU-T-Y.1564.
3. ERROR PERFORMANCE: ERROR PERFORMANCE SHALL BE BETTER THAN THE FOLLOWING PARAMETER
THRESHOLDS TO BE ACCEPTABLE: AVAILABILITY SHALL BE GREATER THAN 99.5% OR BETTER. FRAME LOSS SHALL
BE EQUAL TO ZERO WHEN TESTING AT 1.0 GIGABIT HIGHEST FRAME RATE, AND SHALL MEET ITU-T-Y.1564
STANDARDS. JITTER SHALL BE LESS THAN 3 MSEC. DELAY SHALL BE BETTER THAN 13 MSEC
4. MEAN TIME TO LOSS OF BIT COUNT INTEGRITY (MTTLBCI) SHALL BE GREATER THAN 24 HOURS.
5. ROUND TRIP DELAY (RTD): RTD SHALL BE MEASURED OVER THE 1GB WAVE CIRCUIT AND SHALL BE LESS THAN
OR EQUAL TO 13 MILLISECONDS.
6. PROVIDER MUST CONDUCT A SATISFACTORY 24-HOUR TEST FROM THE DROP SIDE OF THEIR OR LOCAL
EXCHANGE CARRIERS FDP INSTALLED IN THEIR EQUIPMENT SUITE AT THE "A" LOCATION TO THE GOVERNMENT'S
SDP AT THE "Z" LOCATION AND MUST INCLUDE THE EXTENSION BETWEEN THE COMMERCIAL DEMARC AND THE
GOVERNMENT'S SDP AT THE "Z" LOCATION. VENDOR MUST ENSURE A TEST SET IS PLACED AT THE DROP SIDE OF
TELECOMM PROVIDER'S OR LOCAL ACCESS PROVIDERS FDP AS APPLICABLE AT THE "A" LOCATION AND A
SECOND TEST SET AT THE END OF THE FIBER JUMPERS TO BE USED FOR TERMINATION TO THE GOVERNMENT'S
SDP AT THE "Z" LOCATION. TESTING MUST BE SATISFACTORY PRIOR TO TURN OVER TO THE GOVERNMENT FOR
ACCEPTANCE TESTING.
7. TESTING CRITERIA: VENDOR MUST TEST THE CIRCUIT FOR 24 HOURS IAW ITU-T.Y.1564 BENCH MARKING
CONFIGURATION AND PERFORMANCE OF ETHERNET SERVICE. NOTE-ETHERNET FRAME SIZE DESIGNATOR 'H'
(MTU) IS EQUAL TO 9192 BYTES.
8. ALL EQUIPMENT AND CIRCUIT PROBLEMS WILL BE REPORTED BY PHONE TO THE DISA GOC IP BACKBONE
ENGINEERING AND IMPLEMENTATION GROUP, SCOTT AFB, IL. PRIMARY: (C) 618-220-9950, (D) 770-9950 TOLL FREE:
855-868-9950
9. DD FORM 1368 WILL BE SUBMITTED ON THIS TRUNK IAW DISAC-DITCO 350-135-1 BY RNSOC, SCOTT AFB, IL.
GUIDANCE ON SUBMISSION IS AVAILABLE AT <HTTP://WWW.DITCO.DISA.MIL /ASP/PUBLICATIONS.ASP> CLICK ON
"DISA-DITCO CIRCULAR, 350-135-1, DEFENSE COMMERCIAL COMMUNICATIONS ACQUISITION PROCEDURES."
Paragraph V.QUOTE DUE DATE AND TIME change from:
Apr 11, 2018 12:30:00 PM CDT
To:
May 10, 2018 12:30:00 PM CDT