Testing Requirements and Circuit Parameters for Solicitation HC101318QA222

View the file

Other files

File Type Posted
COMBINED_SYNOPSIS_for_HC101318QA222_6-4-18.docx DOCX document
HC101318QA222.v0_solicitation_dated_6-4-18.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CIRCUIT PARAMETERS AND TESTING REQUIREMENTS FOR SOLICITATION HC101318QA222

CIRCUIT SPECIFICATIONS: CONUS TERRESTRIAL-1.544 MB, B8ZS/ESF, CLEAR CHANNEL

1) VENDOR TECHNICAL SPECIFICATIONS

LINE CODING: B8ZS

FRAME FORMAT: ESF

CHANNELIZATION: CLEAR CHANNEL

PHYSICAL TERMINATION: RJ-48

TEST INTERVAL: 2 HOURS

AVAILABILITY: 99.5 %

% ERROR FREE SECONDS (EFS): 98.0 %

SEVERELY ERRORED SECONDS (SES): < 0.2 %

AVERAGE BIT ERROR RATE (BER): 5 X 10-9

RESIDUAL BIT ERROR RATE (RBER): 5 X 10-9

BIPOLAR VIOLATION (BPV): 0 ALLOWED

OUT OF FRAME: 0 ALLOWED

FRAME SLIP: < 1 IN 24 HOURS

DEGRADED MINUTES (DM): < 0.2 %

ROUND TRIP DELAY (RTD): < 10 MS FOR FIRST 620 MILE PLUS 1 MS FOR

EVERY 62 MILES THERE AFTER.

LOSS OF BIT COUNT INTEGRITY (LBCI): <1 IN 24 HOURS

JITTER: ITU-T G.823 OR COMPARABLE U.S. COMMERCIAL INDUSTRY

STANDARD

TEST PATTERN: QRSS FOR DSN CIRCUITS; 2^15 FOR ALL OTHER SERVICE

TYPES

CONUS SECOND PART OF T-1 CIRCUIT PARAMETERS

2) VENDOR WILL TEST COMMERCIAL END TO END, IF THE VENDOR EXTENDED

THE SERVICE THEN THE TEST MUST BE TO THE END OF THE EXTENSION.

TEST WILL NOT BE COMPLETED WITH LOOPS.

3) VENDOR MUST CONDUCT WALK-THROUGH SITE SURVEY PRIOR TO

INSTALLATION AT ALL TERMINATING GOVERNMENT LOCATIONS IF A CIRCUIT

EXTENSION IS REQUIRED.

4) VENDOR MUST COORDINATE SITE VISIT WITH LOCATIONS POC 72 HOURS

IN ADVANCE PRIOR TO COORDINATE ACCESS TO FACILITIES.

5) VENDOR MUST CONTACT DISA IMPLEMENTATION ASSISTANCE TO

ESTABLISH THE COORDINATION AND ACTIVATION PROCESS FOR CIRCUIT

TURN-UP AND/OR ANY SITE CONTACT ISSUES.

6) VENDOR INSTALLATION AND MAINTENANCE INSTRUCTION: IAW THE

UNIQUE INSTALLATION FACTORS IN PARAGRAPH 3.

7) VENDOR REQUIRED TO HAVE CIRCUIT VISIBILITY TO ASSIST IN ANY

CIRCUIT OUTAGES.

8) VENDOR MUST HAVE A 24X7 NETWORK OPERATIONS CENTER.

9) REQUEST ONE-HOUR RESPONSE TIME TURN-AROUND TO REPAIR ONCE

TROUBLE-CALL HAS BEEN REPORTED.

10) CLOCKING: VENDOR WILL NOT PROVIDE TIMING UNLESS THE NETWORK

SERVICE TYPE IS A SIPRNET CIRCUIT.

11) THE VENDOR TEST SET/SETS MUST HAVE THE ABILITY TO PRINT OR

ELECTRONICALLY OUTPUT THE TEST RESULTS AND THOSE RESULTS MUST BE

E-MAILED TO THE ACCEPTING AUTHORITY FOR REVIEW.

12) ALL EQUIPMENT AND CIRCUIT PROBLEMS WILL BE REPORTED TO DISA

CONUS: (C) 618-220-9950 TOLL FREE: 855-868-9950

13) VENDOR MUST PROVIDE THE LONG HAUL CIRCUIT NO. AND LEC CKT ID

PRIOR TO TURN UP TO THE GOVERNMENT.

14) CIRCUIT OPERATIONS: DEDICATED PATH - 24 HOURS A DAY, SEVEN

DAYS PER WEEK

15) VENDOR MUST SHOW SITE PERSONNEL LISTED ON THIS ORDER THE

EXACT TERMINATION POINT WHEN SERVICE IS COMPLETE.

16) VENDOR MUST PROVIDE THE LONG HAUL CIRCUIT NO. AND LEC CKT ID

PRIOR TO TURN UP TO THE GOVERNMENT.

A. DD FORM 1368: DD FORM 1368'S (MODIFIED USE OF LEASED

COMMUNICATION FACILITIES), OR EMAIL EQUIVALENT, WILL BE

SUBMITTED, AS REQUIRED, ON THIS CIRCUIT IAW DISAC-DITCO 350-135-1

BY THE STATION DESIGNATED IN PARAGRAPH 2H AS CCO/CMO. GUIDANCE

ON SUBMISSION IS AVAILABLE AT

HTTP://WWW.DITCO.DISA.MIL/CORPORATELIBRARY/HOME.ASP. CLICK ON

"350-135-1, DEFENSE COMMERCIAL COMMUNICATIONS ACQUISITION

PROCEDURES."

B. ANY ADDRESSEE ON THE TSO WILL NOTIFY ALL ADDRESSEES IMMEDIATELY

BY MESSAGE IDENTIFYING ANY ISSUES, PROBLEMS, OR SITUATIONS WHICH MAY

PREVENT OR DELAY THE IMPLEMENTATION OF THIS TELECOMMUNICATIONS SERVICE ORDER (TSO).

ALL STATIONS WILL REVIEW THE CONFIGURATION, EQUIPMENT, CONTACT

NUMBERS AND ADDRESSES CONTAINED IN THIS TSO AND PROVIDE UPDATES

TO ORIGINATOR OF TSO ANY ERRORS SO THAT SUBSEQUENT TSOS MAY BE

UPDATED.

C. UNSATISFACTORY SERVICE REPORTING INSTRUCTIONS: FOR UNSATISFACTORY

SERVICE OR TO REPORT EQUIPMENT AND/OR CIRCUIT PROBLEMS INVOLVING

DISA PROVIDED TRANSPORT AND/OR EQUIPMENT, PLEASE CONTACT THE

DISN CUSTOMER CONTACT CENTER (DCCC) TOLL FREE NUMBER IS

1-844-347-2457 (1-844-DISA HLP) OPTION 2, COML 1-614-692-0032

OPTION 2, DSN 312-850-0032 OPTION 2.

D. COMPLETION REPORT: FOR STATION DESIGNATED IN PARAGRAPH 2H AS

CCO/CMO, FOR THIS ACTION COMPLETION REPORTS WILL BE SUBMITTED IAW

DISAC 310-130-1, CHAPTER 2 BY DISA GLOBAL IP, DSN 312-770-8627;

COML 618-220-8627. ALL OTHER CCO/CMO RESPONSIBILITIES REMAIN

WITH THE DESIGNATED CCO/CMO IAW DISAC 310-70-1, CHAPTER 8.

E. IMPLEMENTATION ASSISTANCE: FOR CIRCUIT INSTALLATION ASSISTANCE

WITH THE COMMERCIAL LEASED PATH, CONTACT

DCP COMMERICIAL ACTIVATION TEAM (CAT) AT D312-850-0820,

C614-692-0820