Text version
CIRCUIT PARAMETERS AND TESTING REQUIREMENTS FOR SOLICITATION HC101318QA222
CIRCUIT SPECIFICATIONS: CONUS TERRESTRIAL-1.544 MB, B8ZS/ESF, CLEAR CHANNEL
1) VENDOR TECHNICAL SPECIFICATIONS
LINE CODING: B8ZS
FRAME FORMAT: ESF
CHANNELIZATION: CLEAR CHANNEL
PHYSICAL TERMINATION: RJ-48
TEST INTERVAL: 2 HOURS
AVAILABILITY: 99.5 %
% ERROR FREE SECONDS (EFS): 98.0 %
SEVERELY ERRORED SECONDS (SES): < 0.2 %
AVERAGE BIT ERROR RATE (BER): 5 X 10-9
RESIDUAL BIT ERROR RATE (RBER): 5 X 10-9
BIPOLAR VIOLATION (BPV): 0 ALLOWED
OUT OF FRAME: 0 ALLOWED
FRAME SLIP: < 1 IN 24 HOURS
DEGRADED MINUTES (DM): < 0.2 %
ROUND TRIP DELAY (RTD): < 10 MS FOR FIRST 620 MILE PLUS 1 MS FOR
EVERY 62 MILES THERE AFTER.
LOSS OF BIT COUNT INTEGRITY (LBCI): <1 IN 24 HOURS
JITTER: ITU-T G.823 OR COMPARABLE U.S. COMMERCIAL INDUSTRY
STANDARD
TEST PATTERN: QRSS FOR DSN CIRCUITS; 2^15 FOR ALL OTHER SERVICE
TYPES
CONUS SECOND PART OF T-1 CIRCUIT PARAMETERS
2) VENDOR WILL TEST COMMERCIAL END TO END, IF THE VENDOR EXTENDED
THE SERVICE THEN THE TEST MUST BE TO THE END OF THE EXTENSION.
TEST WILL NOT BE COMPLETED WITH LOOPS.
3) VENDOR MUST CONDUCT WALK-THROUGH SITE SURVEY PRIOR TO
INSTALLATION AT ALL TERMINATING GOVERNMENT LOCATIONS IF A CIRCUIT
EXTENSION IS REQUIRED.
4) VENDOR MUST COORDINATE SITE VISIT WITH LOCATIONS POC 72 HOURS
IN ADVANCE PRIOR TO COORDINATE ACCESS TO FACILITIES.
5) VENDOR MUST CONTACT DISA IMPLEMENTATION ASSISTANCE TO
ESTABLISH THE COORDINATION AND ACTIVATION PROCESS FOR CIRCUIT
TURN-UP AND/OR ANY SITE CONTACT ISSUES.
6) VENDOR INSTALLATION AND MAINTENANCE INSTRUCTION: IAW THE
UNIQUE INSTALLATION FACTORS IN PARAGRAPH 3.
7) VENDOR REQUIRED TO HAVE CIRCUIT VISIBILITY TO ASSIST IN ANY
CIRCUIT OUTAGES.
8) VENDOR MUST HAVE A 24X7 NETWORK OPERATIONS CENTER.
9) REQUEST ONE-HOUR RESPONSE TIME TURN-AROUND TO REPAIR ONCE
TROUBLE-CALL HAS BEEN REPORTED.
10) CLOCKING: VENDOR WILL NOT PROVIDE TIMING UNLESS THE NETWORK
SERVICE TYPE IS A SIPRNET CIRCUIT.
11) THE VENDOR TEST SET/SETS MUST HAVE THE ABILITY TO PRINT OR
ELECTRONICALLY OUTPUT THE TEST RESULTS AND THOSE RESULTS MUST BE
E-MAILED TO THE ACCEPTING AUTHORITY FOR REVIEW.
12) ALL EQUIPMENT AND CIRCUIT PROBLEMS WILL BE REPORTED TO DISA
CONUS: (C) 618-220-9950 TOLL FREE: 855-868-9950
13) VENDOR MUST PROVIDE THE LONG HAUL CIRCUIT NO. AND LEC CKT ID
PRIOR TO TURN UP TO THE GOVERNMENT.
14) CIRCUIT OPERATIONS: DEDICATED PATH - 24 HOURS A DAY, SEVEN
DAYS PER WEEK
15) VENDOR MUST SHOW SITE PERSONNEL LISTED ON THIS ORDER THE
EXACT TERMINATION POINT WHEN SERVICE IS COMPLETE.
16) VENDOR MUST PROVIDE THE LONG HAUL CIRCUIT NO. AND LEC CKT ID
PRIOR TO TURN UP TO THE GOVERNMENT.
A. DD FORM 1368: DD FORM 1368'S (MODIFIED USE OF LEASED
COMMUNICATION FACILITIES), OR EMAIL EQUIVALENT, WILL BE
SUBMITTED, AS REQUIRED, ON THIS CIRCUIT IAW DISAC-DITCO 350-135-1
BY THE STATION DESIGNATED IN PARAGRAPH 2H AS CCO/CMO. GUIDANCE
ON SUBMISSION IS AVAILABLE AT
HTTP://WWW.DITCO.DISA.MIL/CORPORATELIBRARY/HOME.ASP. CLICK ON
"350-135-1, DEFENSE COMMERCIAL COMMUNICATIONS ACQUISITION
PROCEDURES."
B. ANY ADDRESSEE ON THE TSO WILL NOTIFY ALL ADDRESSEES IMMEDIATELY
BY MESSAGE IDENTIFYING ANY ISSUES, PROBLEMS, OR SITUATIONS WHICH MAY
PREVENT OR DELAY THE IMPLEMENTATION OF THIS TELECOMMUNICATIONS SERVICE ORDER (TSO).
ALL STATIONS WILL REVIEW THE CONFIGURATION, EQUIPMENT, CONTACT
NUMBERS AND ADDRESSES CONTAINED IN THIS TSO AND PROVIDE UPDATES
TO ORIGINATOR OF TSO ANY ERRORS SO THAT SUBSEQUENT TSOS MAY BE
UPDATED.
C. UNSATISFACTORY SERVICE REPORTING INSTRUCTIONS: FOR UNSATISFACTORY
SERVICE OR TO REPORT EQUIPMENT AND/OR CIRCUIT PROBLEMS INVOLVING
DISA PROVIDED TRANSPORT AND/OR EQUIPMENT, PLEASE CONTACT THE
DISN CUSTOMER CONTACT CENTER (DCCC) TOLL FREE NUMBER IS
1-844-347-2457 (1-844-DISA HLP) OPTION 2, COML 1-614-692-0032
OPTION 2, DSN 312-850-0032 OPTION 2.
D. COMPLETION REPORT: FOR STATION DESIGNATED IN PARAGRAPH 2H AS
CCO/CMO, FOR THIS ACTION COMPLETION REPORTS WILL BE SUBMITTED IAW
DISAC 310-130-1, CHAPTER 2 BY DISA GLOBAL IP, DSN 312-770-8627;
COML 618-220-8627. ALL OTHER CCO/CMO RESPONSIBILITIES REMAIN
WITH THE DESIGNATED CCO/CMO IAW DISAC 310-70-1, CHAPTER 8.
E. IMPLEMENTATION ASSISTANCE: FOR CIRCUIT INSTALLATION ASSISTANCE
WITH THE COMMERCIAL LEASED PATH, CONTACT
DCP COMMERICIAL ACTIVATION TEAM (CAT) AT D312-850-0820,
C614-692-0820