IQO INQUIRY
FM: PL8211
TO: Contractors
DATE (MM/DD/YYYY): 5/31/2018
SUBJECT: HC101318QA126-0001 Amend: 0001
A. TYPE ACTION: ADMIN AMEND
1. PURPOSE: ****HC101318QA126 AMEND 0001 ISSUED TO EXTEND QUOTE DUE DATE TO
15 JUN 18, 4:00 PM CST. ALSO TO EXTEND SERVICE DATE TO 12 NOV 18. THE ALL ELSE
REMAINS THE SAME.
SUBMIT A QUOTE TO PROVIDE, INSTALL, AND MAINTAIN A 1.0GB DISA BACKBONE TRUNK
BETWEEN THE J-PE ROUTER IN BLDG 2904, COMM ROOM, 1195 JABARA AVENUE, SEYMOUR
JOHNSON AFB, NC 27531-5000, AND THE J-PE ROUTER IN BLDG NH-95, ROOM A141, 7927
INGERSOL STREET, NORFOLK, VA 23551-2398.****CONTRACTORS SHALL MEET A MAXIMUM
ROUND-TRIP DELAY OF 10MS.****SEE UNIQUE INSTALL FACTORS.****
2. EACH CONTRACTOR IS RESPONSIBLE FOR READING AND COMPLYING WITH ALL
TECHNICAL ASPECTS OF THIS SOLICITATION, TO INCLUDE READING AND AGREEING
WITH THE STANDARD PROVISIONS, ATTACHMENTS LISTING SPECIFIC TECHNICAL
REQUIREMENTS, PRICE QUOTE REQUIREMENTS, AND REQUESTED SERVICE DATE.
FAILURE TO READ AND ADHERE TO ANY PORTION OF THE INQUIRY SHALL RENDER THE
QUOTE NON-COMPLIANT AND RESULT IN IT BEING EXCLUDED FROM EVALUATION AND
AWARD.
3. THE SERVICE DATE TO BE MET IS: 29 OCT 18 (SIP). THE GOVERNMENT ASSUMES
THAT CONTRACTORS HAVE CONSIDERED ALL ISSUES THAT MAY IMPACT THE SERVICE
DATE. THE GOVERNMENT MAY CANCEL, TERMINATE, OR REQUEST CONSIDERATION
IAW STANDARD PROVISION 42 FOR FAILURE TO MEET CONTRACTUAL SERVICE DATE OR
COMPLY WITH ANY CONTRACT TERMS OR CONDITIONS.
4. CONTRACTORS SHALL SUBMIT QUOTES IAW STANDARD PROVISION 04. QUOTES
SHALL INCLUDE SUFFICIENT DETAIL FOR EFFECTIVE EVALUATION AND SHOULD
NOT SIMPLY REPHRASE OR RESTATE THE GOVERNMENT REQUIREMENTS. RATHER,
THEY MUST PROVIDE CONVINCING RATIONALE TO ADDRESS HOW THE CONTRACTOR
INTENDS TO MEET THE REQUIREMENT. IN RESPONSE TO THIS SOLICITATION, NO
TERMS OR CONDITIONS PLACED UPON THE GOVERNMENT, NOR ASSUMPTIONS WILL BE
ACCEPTED. CONTRACTORS ARE ENCOURAGED TO SUBMIT QUESTIONS AND REQUEST
CLARIFICATIONS OF THE REQUIREMENT (S) BEFORE SUBMITTING QUOTES. QUESTIONS
SHALL BE SUBMITTED TO CONTRACT SPECIALIST AND CONTRACTING OFFICER DURING
THE SOLICITATION PHASE ONLY, AND RESPONSES FOR ALL INTERESTED PARTIES WILL BE
POSTED TO FEDBIZOPPS. QUOTES MUST BE UPLOADED TO IDEAS. IN THE EVENT IDEAS IS
UNAVAILABLE OR QUOTES FAIL TO UPLOAD, QUOTES MAY BE SENT TO THE FOLLOWING
MAILBOX: DISA.SCOTT.DITCO.MBX.VENDOR-QUOTES@MAIL.MIL.
HC101318QA126-0001
5. THIS REQUIREMENT MUST BE WORKED IN CONJUNCTION WITH SOLICITATION
HC101317QA076/TSR RU27SEP175593 AND MUST BE ENGINEERED AND PROVISIONED
TOTALLY DIVERSE END TO END FROM THE GOVERNMENT SERVICE DELIVERY POINTS
(SDP) FROM TSR HC101317QA076/TSR RU27SEP175593; MEANING THE PHYSICAL PATHS
ARE TOTALLY SEPARATE INCLUDING MAN HOLES, CONDUIT, CENTRAL OFFICE LOCATIONS,
AND FIBER BUILDS. ADDITIONALLY AS A MINIMUM MUST HAVE 50 METERS PHYSICAL
SEPARATION FROM TSR HC101317QA076/TSR RU27SEP175593.
6. CONTRACTOR SHALL PROVIDE COLOR POWERPOINT DRAWINGS SHOWING THE
ROUTES FROM THE COMMERCIAL DEMARKS TO THE SUPPORTING CENTRAL OFFICES AND/
OR WIRING CENTERS, ENSURING THE PHYSICAL END TO END DIVERSITY REQUIREMENTS
ARE BEING MET. DRAWINGS MUST INCLUDE SEPARATION DISTANCES, TOTAL FIBER MILES
AND ROUND TRIP DELAY BASED ON ACTUAL DISTANCE IN MILES. REFER TO STANDARD
PROVISION 39 FOR SPECIFIC DOCUMENTATION REQUIREMENTS. SAMPLE DRAWINGS ARE
INCLUDED THE ATTACHMENTS.
7. PRE-AWARD SITE SURVEYS ARE AUTHORIZED (AT CONTRACTOR EXPENSE) WITH
LOCAL POCS AT EACH GOVERNMENT SITE. IT IS HIGHLY RECOMMENDED THAT AT A
MINIMUM, CONTRACTORS CONDUCT PHONE SURVEYS TO ADEQUATELY ASSESS THE
MAGNITUDE OF THE WORK TO BE PERFORMED IN DETERMINING THEIR PRICE STRATEGY.
M. ADDITIONAL INFORMATION:
3. TSR NUMBER: RU27SEP175592C
4. CCSD: XXXXBBEA
Z. DITCO CONTACT:
Dale Rupright
(618) 229-9614 dale.l.rupright.civ@mail.mil
Michael R. Leonard
DITCO Contracting Officer
Add the following:
LOCATION OF TERMINATION A:
ADDRESS: 2904, 1195 JABARA AVENUE, SEYMOUR JOHNSON AFB, NC 27531-5000
ROOM: FRAME ROOM ; N/A FLR
LOCATION: CCC
EXTENSION OF TELECOMMUNICATIONS SERVICE: All facilities between vendor's commercial communications interface point and termination location shall be provided by vendor. All cables shall be run in accordance with local site standards
INTERFACE: INTERFACE: GIGABIT ETHERNET; ELECTRICAL: 1000BASE-LX; PHYSICAL: SNAP
CLICK (SC)
DEMARK: BLDG 2904, FRAME ROOM 1195 JABARA AVENUE
SEYMOUR JOHNSON AFB, NC 27531-5000
NPA/NXX: 919/722
UNIQUE INSTALLATION FACTORS: A. FIBER CABLE X-CONNECT, IN-HOUSE, INSIDE WIRE, SINGLE-MODE, 1310NM, TELCO
B. TELCO MULTIPLEX (COMMERCIAL FIBER POINT OF PRESENCE) COMMERCIAL CARRIER SYSTEM (LOCAL
EXCHANGE CARRIER) PORT: BY LOCAL CARRIER
AMPLIFYING INFO:
C. VENDOR IS RESPONSIBLE FOR INSTALLATION AND MAINTENANCE OF 1GBE SERVICE FROM THE LINE SIDE OF
THE DISA IE1 PROVIDED FIBER TERMINATING PATCH PANEL INSTALLED IN THE JUNIPER MX-240 ROUTER SUITE
(UJEWHRO030) BLDG 2401, ROOM COMM TO THE DROP SIDE OF THE COMMERCIAL FIBER POINT OF PRESENCE
FIBER DISTRIBUTION PANEL BLDG 2904, ROOM COMM USING SINGLE MODE FIBER.
D. VENDOR MUST COORDINATE WITH GOVERNMENT SITE PERSONNEL TO CONDUCT WALK THROUGH SITE
SURVEYS FOR EXACT CABLE FT. FROM THE DISA PROVIDED FIBER TERMINATING PATCH PANEL INSTALLED IN THE
JUNIPER MX-240 ROUTER SUITE BLDG 2401, ROOM COMM TO THE COMMERCIAL FIBER POINT OF PRESENCE BLDG
2904, ROOM COMM.
E. VENDOR MUST PROVIDE FIBER STRANDS FROM THE DISA PROVIDED FIBER PATCH PANEL INSTALLED IN THE
JUNIPER MX-240 ROUTER TO THE COMMERCIAL DEMARC LOCATION WITHOUT SPLICING AND OR USE OF
CONNECTORS TO CONNECT 2 OR MORE FIBER STRANDS MEANING THE FIBER CANNOT BE BROKEN IN THE MIDDLE
AND MUST BE CONTINUOUS.
F. VENDOR MUST SCHEDULE/COORDINATE WITH THE POC'S LISTED ON THIS ORDER 72 HOURS IN ADVANCE PRIOR
TO SITE SURVEYS OR INSTALLATIONS.
G. VENDOR IS RESPONSIBLE IS RESPONSIBLE ALL THE WAY THROUGH TO INCLUDE FROM FRAME ROOM TO COMM
ROOM.
INSIDE WIRE INSTALLATION / MAINTENANCE REQUIRED: INSIDE WIRE INSTL/MAINT: CPIWI-YES/CPIWM-YES
CONTACT: PRI: SSGT GREGORY COYLE, D722-5030, C919-722-5030
EMAIL: GREGORY.COYLE@US.AF.MIL
ALT: A1C JIMMY GODFREY, D722-5030, C919-722-5030
EMAIL: JIMMY.GODFREY@US.AF.MIL
ORG EMAIL: CIRCUIT.ACTIONS7@US.AF.MIL
ALT: TSGT MARCUS NATIVIDAD
EMAIL: MARCUS.NATIVIDAD@US.AF.MIL
ORG EMAIL: 4CS.SCOI@SEYMOURJOHNSON.AF.MIL
C919-722-7304; D722-7304
Add the following:
LOCATION OF TERMINATION B:
ADDRESS: NH-95, 7927 INGERSOL STREET, NORFOLK, VA 23551-2398
ROOM: A141; 1ST FLR
LOCATION: BCC
EXTENSION OF TELECOMMUNICATIONS SERVICE: All facilities between vendor's commercial communications interface point and termination location shall be provided by vendor. All cables shall be run in accordance with local site standards
INTERFACE: INTERFACE: GIGABIT ETHERNET; ELECTRICAL: 1000BASE-LX; PHYSICAL: SNAP
CLICK (SC)
DEMARK: BLDG NH-95, ROOM A141,
7927 INGERSOL STREET, NORFOLK, VA 23551-2398
NPA/NXX: 757/836
UNIQUE INSTALLATION FACTORS: 1. FIBER CABLE X-CONNECT, IN-HOUSE, INSIDE WIRE, SINGLE-MODE, 1310NM, TELCO
2. TELCO MULTIPLEX (COMMERCIAL FIBER POINT OF PRESENCE) COMMERCIAL CARRIER SYSTEM (LOCAL
EXCHANGE CARRIER) PORT: BY LOCAL CARRIER
AMPLIFYING INFO:
A. VENDOR IS RESPONSIBLE FOR INSTALLATION AND MAINTENANCE OF THE SERVICE FROM THE LINE SIDE OF
THE DISA IE1 PROVIDED FIBER TERMINATING PATCH PANEL INSTALLED IN THE CISCO ASR-9010 ROUTER SUITE
(UJEWHRO030) IN BLDG NH-95, RM A141 TO THE DROP SIDE OF THE COMMERCIAL FIBER POINT OF PRESENCE
FIBER DISTRIBUTION PANEL BLDG NH-95, RM A141 USING SINGLE MODE FIBER. COORDINATE TYPE CONNECTORS
TO BE USED FOR TERMINATION TO THE DISA PROVIDED PATCH PANEL.
B. VENDOR MUST COORDINATE WITH GOVERNMENT SITE PERSONNEL TO CONDUCT WALK THROUGH SITE
SURVEYS FOR EXACT CABLE FT. FROM THE DISA PROVIDED FIBER TERMINATING PATCH PANEL INSTALLED IN THE
CISCO ASR-9010 ROUTER SUITE BLDG NH-95, RM A141TO
THE COMMERCIAL FIBER POINT OF PRESENCE BLDG NH-95, RM A141.
C. VENDOR MUST PROVIDE FIBER STRANDS FROM THE DISA PROVIDED FIBER PATCH PANEL INSTALLED IN THE
CISCO ASR-9010 ROUTER TO THE COMMERCIAL DEMARC LOCATION WITHOUT SPLICING AND OR USE OF
CONNECTORS TO CONNECT 2 OR MORE FIBER STRANDS MEANING THE FIBER CANNOT BE BROKEN IN THE MIDDLE
AND MUST BE CONTINUOUS.
D. VENDOR MUST SCHEDULE/COORDINATE WITH THE POC'S LISTED ON THIS ORDER 72 HOURS IN ADVANCE PRIOR
TO SITE SURVEYS OR INSTALLATIONS.
INSIDE WIRE INSTALLATION / MAINTENANCE REQUIRED: INSIDE WIRE INSTL/MAINT: CPIWI-YES/CPIWM-YES
CONTACT: PRI: MINDY MEADE, D836-6807, C757-836-6807
EMAIL: MINDY.MEADE@NAVY.MIL
ALT: JOE MOEHLMAN, D836-5539, C757-836-5539
EMAIL: JOE.MOEHLMAN@NAVY.MIL
ALT: FLOYD SPEARS, D836-5209, C757-836-5209
EMAIL: FLOYD.SPEARS@NAVY.MIL
ALT: TECH CONTROL 24/7 WATCH, D836-5511, C757-836-5511
ORG EMAIL: NCTLDHR_DISAREP@NAVY.MIL