About this file

HC101317QB098-0002 dated 10/13/17

View the file

Other files

File Type Posted
GGTG000179EBM.v0.zip ZIP file
HC101317QB098.v0.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

IQO INQUIRY

FM: PL8211

TO: Contractors

DATE (MM/DD/YYYY): 10/13/2017

SUBJECT: HC101317QB098-0002 Amend: 0002

A. TYPE ACTION: AMEND

1. PURPOSE: THE PURPOSE OF THIS AMENDMENT IS TO:

1. REVISE PURPOSE STATEMENT;

2. REVISE CIRCUIT REQUIREMENTS;

3. REVISE TESTING SPECIFICATIONS;

4. REVISE UNIQUE INSTALL FACTS AND AMPLIFYING INFO;

5. CHANGE COMMERCIAL DEMARCATION POINT TO "BLDG 891, ROOM 145

(COMPUTER), 7879 WARDLEIGH ROAD, HILL AFB, UT; AND

6. CHANGE SERVICE DELIVERY POINT TO "BLDG 891, ROOM 145 (COMPUTER),

7879 WARDLEIGH ROAD, HILL AFB, UT."

RECAP:

1. SUBMIT A QUOTE TO PROVIDE, INSTALL, AND MAINTAIN A LEASED 1.0GB

ETHERNET IP BACKBONE CIRCUIT BETWEEN DISA IE1 PROVIDED FIBER

TERMINATING PATCH PANEL BLDG 31A, ROOM R109, 217 DELL RANGE BLVD,

CHEYENNE, WY, AND DISA IE1 PROVIDED CISCO ASR-9010 ROUTER (UJEWHIL040)

(IPT-PE1) BLDG 891, ROOM 145, 7879 WARDLEIGH ROAD, HILL AFB, UT.**SEE

UNIQUE INSTALL FACTORS.**

A. THE COMMITTED INFORMATION RATE (CIR) (1.0GBE) WILL REQUIRE VENDOR

TO DELIVER 1.0GB ETHERNET INTERFACE (OPITCAL HANDOFF-1000BASE-LX-

SINGLE MODE FIBER) AT THE DROP SIDE OF THE COMMERCIAL DEMARC'S AT THE

"A" AND "Z" LOCATIONS.

B. TELECOMM PROVIDER MUST PROVIDE TOTAL FIBER MILES AND ROUND TRIP

DELAY (RTD) FROM THE CUSTOMER "A" LOCATION TO THE CUSTOMER "Z"

LOCATION.

C. VENDOR MUST DELIVER 1.0GBE CIRCUIT 2W (UNPROTECTED) FROM COML

DEMARC TO GOVERNMENT SERVICE DELIVERY POINT AT THE "Z" BOTH LOCATION.

FOR THE "A" LOCATION TELECOMM PROVIDER MUST TERMINATE CIRCUIT TO THE

DROP SIDE OF THE THEIR OR LOCAL ACCESS PROVIDER'S FDP.

2. EACH CONTRACTOR IS RESPONSIBLE FOR READING AND COMPLYING WITH ALL

TECHNICAL ASPECTS OF THIS SOLICITATION, TO INCLUDE READING AND

AGREEING WITH THE STANDARD PROVISIONS, ATTACHMENTS LISTING SPECIFIC

TECHNICAL REQUIREMENTS, PRICE QUOTE REQUIREMENTS, AND REQUESTED

SERVICE DATE. FAILURE TO READ AND ADHERE TO ANY PORTION OF THE

INQUIRY SHALL RENDER THE QUOTE NON-COMPLIANT AND RESULT IN IT BEING

EXCLUDED FROM EVALUATION AND AWARD.

HC101317QB098-0002

3. THE SERVICE DATE TO BE MET IS: 28 NOV 17 (SIP). THE GOVERNMENT

ASSUMES THAT CONTRACTORS HAVE CONSIDERED ALL ISSUES THAT MAY IMPACT

THE SERVICE DATE. THE GOVERNMENT MAY CANCEL, TERMINATE, OR REQUEST

CONSIDERATION IAW STANDARD PROVISION 42 FOR FAILURE TO MEET

CONTRACTUAL SERVICE DATE OR COMPLY WITH ANY CONTRACT TERMS OR

CONDITIONS.

4. CONTRACTORS SHALL SUBMIT QUOTES IAW STANDARD PROVISION 04. QUOTES

SHALL INCLUDE SUFFICIENT DETAIL FOR EFFECTIVE EVALUATION AND SHOULD

NOT SIMPLY REPHRASE OR RESTATE THE GOVERNMENT REQUIREMENTS. RATHER,

THEY MUST PROVIDE CONVINCING RATIONALE TO ADDRESS HOW THE CONTRACTOR

INTENDS TO MEET THE REQUIREMENT. IN RESPONSE TO THIS SOLICITATION, NO

TERMS OR CONDITIONS PLACED UPON THE GOVERNMENT, NOR ASSUMPTIONS WILL

BE ACCEPTED. RESPONSES TO CONTRACTORS ARE ENCOURAGED TO SUBMIT

QUESTIONS AND REQUEST CLARIFICATIONS OF THE REQUIREMENT (S) BEFORE

SUBMITTING QUOTES. QUESTIONS SHALL BE SUBMITTED TO CONTRACT

SPECIALIST AND CONTRACTING OFFICER DURING THE SOLICITATION PHASE ONLY,

AND RESPONSES FOR ALL INTERESTED PARTIES WILL BE POSTED TO FEDBIZOPPS.

QUOTES MUST BE UPLOADED TO IDEAS. IN THE EVENT IDEAS IS UNAVAILABLE OR

QUOTES FAIL TO UPLOAD, QUOTES MAY BE SENT TO THE FOLLOWING MAILBOX:

DISA.SCOTT.DITCO.MBX.VENDOR-QUOTES@MAIL.MIL

5. THIS REQUIREMENT MUST BE WORKED IN CONJUNCTION WITH SOLICITATION

HC101317QA944/TSR RU15FEB175107.

6. ESTABLISH TSP: TSP0GL3PQ-01

M. ADDITIONAL INFORMATION:

3. TSR NUMBER: RU15FEB175102A

4. CCSD: XXXXBGU3

Z. DITCO CONTACT:

Christopher OConnor christopher.t.oconnor2.civ@mail.mil

Paul A. Heard

DITCO Contracting Officer

Unless otherwise specified, all other terms and conditions are unchanged.

Paragraph E.SERVICE DATE change from:

Feb 2, 2018

To:

Nov 28, 2017

Paragraph V.QUOTE DUE DATE AND TIME change from:

Sep 25, 2017 4:00:00 PM CDT

Nov 13, 2017 4:00:00 PM CST

Location A, LOCATION OF TERMINATION A change from:

ADDRESS: (BLDG) 31A; 217 DELL RANGE BLVD; CHEYENNE, WY, 82009

ROOM: R109; 1 FL

LOCATION: CHEYENNE

ADDRESS: BLDG 31A; 217 DELL RANGE BLVD; CHEYENNE, WY, 82009

ROOM: 109; 1ST FL

LOCATION: CHEYENNE

Location A, DEMARK change from:

(BLDG) 31A; RM: R109,

217 DELL RANGE BLVD;

CHEYENNE, WY 82009

(PMRY POC) STAFF SERGEANT BENJAMIN N HEBERT;

(UNCLASS USER) BENJAMIN.N.HEBERT.MIL@MAIL.MIL;

(CMCL) 307-772-6796; (DSN) 388-6796

To:

BLDG 31A; RM: R109,

217 DELL RANGE BLVD;

CHEYENNE, WY 82009

(PMRY POC) STAFF SERGEANT BENJAMIN N HEBERT;

(UNCLASS USER) BENJAMIN.N.HEBERT.MIL@MAIL.MIL;

(CMCL) 307-772-6796; (DSN) 388-6796

Location A, UNIQUE INSTALLATION FACTORS change from:

UNIQUE INST FACT:

(1) COMMERCIAL FIBER POINT OF PRESENCE

AMPLIFYING INFO:

A. VENDOR IS RESPONSIBLE FOR INSTALLATION AND MAINTENANCE

OF SINGLE MODE FIBER TO DROP SIDE OF COMMERCIAL FIBER POINT OF PRESENCE FIBER DISTRIBUTION

PANEL BLDG 31A, ROOM R109. COORDINATE TYPE CONNECTORS FOR TERMINATION TO DISA PROVIDED

PATCH PANEL.

B. VENDOR MUST SCHEDULE/COORDINATE WITH POC'S LISTED ON

THIS ORDER 72 HOURS IN ADVANCE PRIOR TO SITE SURVEYS OR

INSTALLATIONS.

(1) COMMERCIAL FIBER POINT OF PRESENCE

A. VENDOR TERMINATE 1GB ETHERNET INTERFACE TO THE DROP SIDE OF VENDOR'S FIBER DISTRIBUTION

PANEL (FDP) INSTALLED IN THEIR EQUIPMENT SUITE BLDG 31A, ROOM

R109;

B. TELECOM VENDOR'S RESPONSIBLITY STOPS AT THE COMMERCIAL DEMARC. NO INSIDE WIRE REQUIRED;

C. CIRCUIT MUST BE TAGGED WITH VENDOR'S LONG HUAL CIRCUIT ID AND LOCAL EXCHANGE CARRIER

CIRCUIT NO. AS APPLICABLE AT DROP SIDE OF THEIR POINT OF PRESENCE (FIBER DISTRIBUTION PANEL)

BLDG 31A, ROOM R109. ADDITIONALLY, VENDOR MUST SHOW SITE PERSONNEL LISTED ON THIS ORDER

THE EXACT TERMINATION POINT WHEN CIRCUIT INSTALLATION IS COMPLETE;

D. VENDOR MUST SCHEDULE/COORDINATE WITH POC'S LISTED ON THIS ORDER 72 HOURS IN ADVANCE

PRIOR TO SITE SURVEYS OR INSTALLATIONS.

Location A, CONTACT change from:

(PMRY POC) STAFF SERGEANT BENJAMIN N HEBERT;

(UNCLASS USER) BENJAMIN.N.HEBERT.MIL@MAIL.MIL;

(CMCL) 307-772-6796; (DSN) 388-6796

(ALT POC) TECHNICAL SERGEANT AIR FORCE CHARLES L LANDGRAF;

(UNCLASS USER) CHARLES.L.LANDGRAF.MIL@MAIL.MIL;

(CMCL) 307-772-6162; (DSN) 388-6162

To:

(PMRY POC)

STAFF SERGEANT BENJAMIN N HEBERT;

BENJAMIN.N.HEBERT.MIL@MAIL.MIL;

(CMCL) 307-772-6796; (DSN) 388-6796

(ALT POC)

TECHNICAL SERGEANT AIR FORCE CHARLES L LANDGRAF;

CHARLES.L.LANDGRAF.MIL@MAIL.MIL;

(CMCL) 307-772-6162; (DSN) 388-6162

Location A, INTERFACE change from:

INTERFACE: ELECTRICAL: OPTICAL; PHYSICAL: LC;; (PHYSICAL) LC;

(ELECTRICAL)

OPTICAL

ELECTRICAL: OPTICAL; PHYSICAL: LC;; (PHYSICAL) LC; (ELECTRICAL) OPTICAL

Location B, LOCATION OF TERMINATION B change from:

ADDRESS: (BLDG) 1038; 175 E STEWART AVE; PETERSON AFB, CO, 80914

ROOM: 35; 1 FL

LOCATION: PTRSNAFB

ADDRESS: 7879 WARDLEIGH ROAD; BLDG 891; HILL AFB, UT 84056

ROOM: 145

LOCATION: HILL AFB

Location B, DEMARK change from:

(BLDG) 1038, RM: 35

175 E STEWART AVE;

PETERSON AFB, CO, 80914

(PMRY POC) MR. KODY S MCNAIL;

(UNCLASS ORG) 21CS.SCOIN.CA@US.AF.MIL;

(UNCLASS USER) KODY.MCNAIL.2@US.AF.MIL;

(CMCL) 719-556-9665; (DSN) 312-834-9665

To:

BLDG 891, ROOM 145 (COMPUTER)

7879 WARDLEIGH ROAD, HILL AFB, UT 84056

Location B, UNIQUE INSTALLATION FACTORS change from:

(1) FIBER CABLE X-CONNECT, IN-HOUSE, INSIDE WIRE, SINGLE-MODE, 1310NM, TELCO; COMMERCIAL FIBER

POINT OF PRESENCE.

(2) FIBER TERMINATING PATCH PANEL (GFE) (DISA IE1 PROVIDED)

RACK/SHELF/PORT - TBD

(3) FIBER CABLE X-CONNECT, IN-HOUSE, INSIDE WIRE, SINGLE-MODE, 1310NM, DISA IE4

(4) OPTICAL INTERFACE CARD (GFE)(DISA IE1 PROVIDED) RACK/SHELF/SLOT/PORT - TBD

(5) CISCO ASR-9010 ROUTER (GFE)(DISA IE1 PROVIDED) NODE ID: UJEWPET030

A. VENDOR IS RESPONSIBLE FOR INSTALLATION AND MAINTENANCE

OF SINGLE MODE FIBER FROM THE DROP SIDE OF COMMERCIAL FIBER POINT OF PRESENCE FIBER

DISTRIBUTION PANEL BLDG 1038, ROOM 35, TO LINE SIDE OF DISA IE1 PROVIDED FIBER TERMINATING

PATCH PANEL INSTALLED IN CISCO ASR-9010 ROUTER SUITE

(UJEWPET030) BLDG 1038, ROOM 35. COORDINATE

TYPE CONNECTORS FOR TERMINATION TO DISA PROVIDED PATCH PANEL.

B. VENDOR MUST PROVIDE FIBER STRANDS FROM THE DISA PROVIDED

FIBER PATCH PANEL TO THE DROP SIDE OF THEIR POP/FIBER

DISTRIBUTION PANEL WITHOUT SPLICING AND OR USE OF

CONNECTORS TO CONNECT 2 OR MORE FIBER STRANDS MEANING THE FIBER CANNOT BE BROKEN IN THE

MIDDLE AND MUST BE CONTINUOUS.

C. THE CIRCUIT MUST BE TAGGED WITH THE VENDOR'S CIRCUIT ID AS APPLICABLE AT THE DROP SIDE OF

THEIR POINT OF PRESENCE (FIBER DISTRIBUTION PANEL) BLDG 1038, ROOM 35.

ADDITIONALLY, VENDOR MUST SHOW SITE PERSONNEL LISTED ON THIS ORDER THE EXACT

TERMINATION POINT WHEN INSTALLATION IS COMPLETE.THE CIRCUIT MUST BE TAGGED WITH THE

LOCAL CIRCUIT ID AND LONG HAUL CIRCUIT NO. AT THE LINE SIDE OF THE DISA PROVIDED FIBER

TERMINATING PATCH PANEL BLDG 1038, ROOM 35.

D. VENDOR MUST SCHEDULE/COORDINATE WITH THE POC'S LISTED ON THIS ORDER 72 HOURS IN

ADVANCE PRIOR TO SITE SURVEYS OR INSTALLATIONS.

(1) COMMERCIAL FIBER POINT OF PRESENCE;

(2) FIBER CABLE X-CONNECT, IN-HOUSE, INSIDE WIRE, SINGLE-MODE, 1310NM, TELCO;

A. VENDOR IS RESPONSIBLE FOR INSTALLATION AND MAINTENANCE OF SINGLE MODE FIBER FROM THE

DROP SIDE OF COMMERCIAL FIBER POINT OF PRESENCE FIBER DISTRIBUTION PANEL BLDG 891, ROOM 145

TO LINE SIDE OF DISA IE1 PROVIDED FIBER TERMINATING PATCH PANEL INSTALLED IN CISCO ASR-9010

ROUTER SUITE (UJEWHIL040) BLDG 891, ROOM 145. TERMINATE WITH "SC" CONNECTORS TO DISA

PROVIDED FIBER TERMINATING PATCH PANEL;

B. VENDOR MUST PROVIDE FIBER STRANDS FROM THE DISA PROVIDED FIBER PATCH PANEL TO THE DROP

SIDE OF THEIR POP/FIBER DISTRIBUTION PANEL WITHOUT SPLICING AND OR USE OF CONNECTORS TO

CONNECT 2 OR MORE FIBER STRANDS MEANING THE FIBER CANNOT BE BROKEN IN THE MIDDLE AND

MUST BE CONTINUOUS;

C. CIRCUIT MUST BE TAGGED WITH VENDOR'S LONG HUAL CIRCUIT ID AND LOCAL EXCHANGE CARRIER

CIRCUIT NO. AS APPLICABLE AT DROP SIDE OF THEIR POINT OF PRESENCE (FIBER DISTRIBUTION PANEL)

BLDG 891, ROOM 145. ADDITIONALLY, VENDOR MUST SHOW SITE PERSONNEL LISTED ON THIS ORDER THE

EXACT TERMINATION POINT WHEN CIRCUIT INSTALLATION IS COMPLETE;

D. VENDOR MUST SCHEDULE/COORDINATE WITH THE POC'S LISTED ON THIS ORDER 72 HOURS IN

ADVANCE PRIOR TO SITE SURVEYS OR INSTALLATIONS.

Location B, CONTACT change from:

(PMRY POC) MR. KODY S MCNAIL;

(UNCLASS ORG) 21CS.SCOIN.CA@US.AF.MIL;

(UNCLASS USER) KODY.MCNAIL.2@US.AF.MIL;

(CMCL) 719-556-9665; (DSN) 312-834-9665

(ALT POC) STAFF SERGEANT NOAH PETRAMALE;

(UNCLASS USER) NOAH.PETRAMALE@US.AF.MIL;

(CMCL) 719-556-8357

To:

(PRI)

MR. DENNIS E VOIGT

DISA.HILL.EIS.LIST.FACILITIES-MGMT-NETWORK-TEAM@MAIL.MIL

DENNIS.E.VOIGT.CIV@MAIL.MIL

(C) 801-605-7464; (D) 388-7464

(ALT)

MR. BRIAN D RASBAND;

DISA.OGDEN.EIS.LIST.NETWORK-TEAM@MAIL.MIL;

BRIAN.D.RASBAND.CIV@MAIL.MIL

(C) 801-605-7608; (D) 388-7608

Location B, INTERFACE change from:

INTERFACE: ELECTRICAL: OPTICAL; PHYSICAL: LC;; (PHYSICAL) LC;

(ELECTRICAL)

OPTICAL

INTERFACE: ELECTRICAL: OPTICAL; PHYSICAL: SC; OPTICAL

Location B, INSIDE WIRE INSTALLATION / MAINTENANCE REQUIRED change from:

INSIDE WIRE INSTL/MAINT: CPIWI-YES/CPIWM-YES

YES/YES

Location B, NPA/NXX change from:

719/556

To:

801/605

Location B, COUNTRY CODE change from:

Location B, TERMINAL EQUIPMENT change from:

CISCO ASR 9010 IPT-PE ROUTER (GFE - DISA) EQUIPMENT

CML FIBER POP EQUIPMENT INFORMATION: COMMERCIAL FIBER POINT OF PRESENCE

STANDARD PROVISION - 30, TEXT change from:

This contract for this telecommunications service shall have an estimated contract period of 36 months. However, this estimated contract period is not guaranteed. The minimum service period shall be one month. Accordingly, after meeting minimum service period, U.S. Government may discontinue service, at no additional cost to U.S. Government. U.S.

Government will provide Contractor/Telecommunications Provider (TP) 30 days notice prior to discontinuing service.

Quotes that do not accept the minimum one month service period may be excluded from the competition and found unacceptable. In the event U.S. Government is unable to obtain quotes that meet this minimum service period, U.S.

Government may consider quotes with a minimum service period greater than one month.

The Government reserves the right to re-solicit these contracted services prior to the end of the estimated contract period when commercial market pricing demonstrates these services become available at lower prices.

ACCEPTABLE CONTRACTOR/TELECOMMUNICATIONS PROVIDER (TP) RESPONSE: "UNDERSTAND/WILL

COMPLY."

This telecommunications service contract shall continue on a month to month basis with a not to exceed date of 27 NOV 20.

After this period the contract will be considered expired with no authority for service to continue unless mutually agreeable by both parties. Should service continue through the end of this contract period, no modification will be issued to authorize discontinuance of service. The minimum service period shall be one month. Accordingly the U.S. Government may discontinue service, at no additional cost to U.S. Government. U.S. Government will provide Contractor/Telecommunications

Provider (TP) 30 days notice prior to discontinuing service before the not to exceed period. Contractors shall consider the ability of the Government to discontinue service with 30 days notice when determining the reasonableness of incurring any costs. See DFARS 252.239-7007, Cancellation Or Termination Of Orders.

Quotes that do not accept the minimum one month service period may be excluded from the competition and found unacceptable. In the event U.S. Government is unable to obtain quotes that meet this minimum service period, U.S.

Government may consider quotes with a minimum service period greater than one month.

The Government reserves the right to re-solicit these contracted services prior to the end of the not to exceed contract period when commercial market pricing demonstrates these services become available at lower prices.

ACCEPTABLE CONTRACTOR/TELECOMMUNICATIONS PROVIDER (TP) RESPONSE: "UNDERSTAND/WILL

COMPLY."

STANDARD PROVISION - 30, PRESCRIPTION change from:

In Inquiries & Orders for START. DO NOT USE with SP-31 or SP-32

To:

Include in Inquiries and Orders or Circuit Demands for the START of new service (including REAWARD) when an indefinite term contract is to be established (month-to-month contract). The “fill-in” information required to complete this SP is the not to exceed service date. This is the date that the service will expire. Unless otherwise specified in the Quote, the minimum service period shall be one month (30 days). Remove paragraph 2 on Order or Circuit Demand. Cannot be used with SP 31 or

32.

STANDARD PROVISION - 30, LAST UPDATED change from:

FEB 2017

AUG 2017

Attachments Begin After This Page.

CIRCUIT PARAMETERS FOR SOLICITATION HC101317QB098

CIRCUIT REQUIRES THE FOLLOWING PARAMETERS:

(A) FIBER TERMINATION: FRAME FORMAT: 1.0GB ETHERNET (OPITCAL HANDOFF-

1000BASE-LX-SINGLE MODE FIBER), 802.3Z, 1310NM. "SC" CONNECTORS;

(B) COMMITTED INFORMATION RATE (CIR)-1.0GB;

(C) 1.0GB ETHERNET FRAMING REQUIRED AT COMMERCIAL DEMARC AT THE A

AND Z LOCATIONS;

(D) NO NETWORK INTERFACE UNIT, DEDICATED PATH;

(E) GFE CLOCKING: VENDOR ESFU (OR EQUIVALENT) NOT TO BE ENGINEERED

INTO CIRCUIT;

(F) TESTING CRITERIA: VENDOR MUST TEST THE CIRCUIT END TO END FOR 24

HOURS IAW THE FULL ITU-T.Y.1564 BENCH MARKING METHODOLOGY FOR

NETWORK INTERCONNECT DEVICES STANDARD, AND AT THE COMMITTED

INFORMATION RATE (CIR) IAW ITU-T-Y.1564 FOR AN ADDITIONAL 48 HOURS;

(G) LINE MUST REMAIN FULLY OPERATIONAL AND AVAILABLE TO USERS 24

HOURS A DAY, SEVEN DAYS PER WEEK, AT LEAST 99.5% OR BETTER;

(H) 1 HOUR RESPONSE TIME TO RESPOND TO CUSTOMER UPON RECIEPT OF

TROUBLE;

(I) VENDOR REQUIRED TO HAVE CIRCUIT VISIBILITY TO ASSIST IN ANY CIRCUIT

OUTAGES;

(J) VENDOR MUST HAVE A 24X7 NETWORK OPERATIONS CENTER;

(K) TELECOMM PROVIDER MUST MAINTAIN OPERATIONS, MAINTENANCE AND

ADMINISTRATION MONITORING OF ETHERNET CIRCUIT IAW ITU-T-Y.1731;

(L) THE COMMERCIAL CIRCUIT WILL BE ACCEPTED ON BEHALF OF THE

GOVERNMENT BY THE DISA GOC IP BACKBONE ENGINEERING AND

IMPLEMENTATION GROUP, SCOTT AFB, IL; (C) 618-220-8627 (D) 770-8627; AND

(M) VENDOR MUST PROVIDE THE LONG HAUL CIRCUIT NO. AND LEC CKT ID'S AS

APPLICABLE TO THE DISA IE161 PROGRAM OFFICE PRIOR TO TURN UP TO THE

GOVERNMENT; PRIMARY: RAY BURKE (301) 225-2550; ALTERNATE: KEN DIEF (301)

225-2416.

Testing Requirements for Solicitation HC101317QB098

A. COMPLETION REPORT: SERVICE WILL BE ACCEPTED ON BEHALF OF THE U.S.

GOVERNMENT BY DISA CONUS IP/D312-770-8627,C618-220-8627 WHO WILL SUBMIT

A COMPLETION REPORT IAW DISAC 310-130-1, CHAP 2 OF DISAC 310-70-1, CHAP 8.

B. VENDOR MUST PROVIDE LIGHT LEVEL READINGS (DB LOSS) ON EXTENSION

FROM COMMERCIAL POP TO GOVERNMENT SERVICE DELIVERY POINT (SDP) AT

THE "Z" LOCATION PRIOR TO CIRCUIT TURN UP TO THE GOVERNMENT ENSURING

LEVELS ARE WITHIN SPECS. LIGHT LEVELS MUST BE ADJUSTED TO -5 TO -13.

C. VENDOR MUST CONDUCT WALK-THROUGH SITE SURVEY PRIOR TO

INSTALLATION AT THE "Z" LOCATION ONLY.

D. VENDOR MUST CONTACT DISA GOC IP BACKBONE ENGINEERING AND

IMPLEMENTATION GROUP UPON RECEIPT OF A VALID TSO TO ESTABLISH THE

COORDINATION AND ACTIVATION PROCESS.; (C) 618-220-8627 (D) 770-8627.

E. PROVIDER MUST CONDUCT A SATISFACTORY 72 HOUR TEST FROM THE DROP

SIDE OF THEIR OR LOCAL EXCHANGE CARRIERS FDP INSTALLED IN THEIR

EQUIPMENT SUITE AT THE "A" LOCATION TO THE GOVERNMENT'S SDP AT THE "Z"

LOCATION AND MUST INCLUDE THE EXTENSION BETWEEN THE COMMERCIAL

DEMARC AND THE GOVERNMENT'S SDP AT THE "Z" LOCATION. VENDOR MUST

ENSURE A TEST SET IS PLACED AT THE DROP SIDE OF TELECOMM PROVIDER'S OR

LOCAL ACCESS PROVIDERS FDP AS APPLICABLE AT THE "A" LOCATION AND A

SECOND TEST SET AT THE END OF THE FIBER JUMPERS TO BE USED FOR

TERMINATION TO THE GOVERNMENT'S SDP AT THE "Z" LOCATION. TESTING

MUST BE SATISFACTORY PRIOR TO TURN OVER TO THE GOVERNMENT FOR

ACCEPTANCE TESTING. TESTING CRITERIA:; VENDOR MUST TEST THE CIRCUIT

FOR 24 HOURS IAW THE FULL ITU-T.Y.1564 BENCH MARKING METHODOLOGY FOR

NETWORK INTERCONNECT DEVICES STANDARD, AND AT THE COMMITTED

INFORMATION RATE (CIR) IAW ITU-T-Y.1564 FOR AN ADDITIONAL 48 HOURS.

F. VENDOR WINNING AWARD IS RESPONSIBLE FOR INSTALLATION AND

MAINTENANCE OF 1.0GBE CIRCUIT IAW THE UNIQUE INSTALLATION FACTORS.

G. INSIDE WIRING IS AUTHORIZED IAW THE UNIQUE INSTALLATION FACTORS.

H. VENDOR MUST COORDINATE SITE VISIT WITH POC'S 72 HOURS IN ADVANCE

PRIOR TO REQUIRING ACCESS TO FACILITIES AT BOTH USER LOCATIONS. IF

UNABLE TO REACH SITE POC'S CONTACT KEN DIEF OR RAY BURKE IMMEDIATELY

FOR ASSISTANCE AT: (301) 225-2416/2550.

I. ALL EQUIPMENT AND CIRCUIT PROBLEMS WILL BE REPORTED BY PHONE TO

THE DISA GOC IP BACKBONE ENGINEERING AND IMPLEMENTATION GROUP,

SCOTT AFB, IL.; PRIMARY: (C) 618-220-9950, (D) 770-9950; TOLL FREE: 855-868-9950.

J. DD FORM 1368 WILL BE SUBMITTED ON THIS TRUNK IAW DISAC-DITCO 350-135-1

BY RNSOC, SCOTT AFB, IL. GUIDANCE ON SUBMISSION IS AVAILABLE AT

CLICK ON "DISA-DITCO CIRCULAR, 350-135-1, DEFENSE COMMERCIAL

COMMUNICATIONS ACQUISITION PROCEDURES."

K. MINIMUM TECHNICAL SPECIFICATIONS:; SPECIFIC FORMAT TO BE USED IS:;

LINE RATE: 1.0709 GIGABITS/S, +- 100 PPM ; LINE CODE: OPTIC.

L. TEST AND ACCEPTANCE: 1.0GB ETHERNET CIRCUITS SHALL PASS A FULLY

DOCUMENTED SATISFACTORY 72 HOUR SOAK TEST BY DISA GOC AT SCOTT AFB,

IL.; PRIMARY: (C) 618-229-8691 (D) 779-8691.

M. TESTING PARAMETERS AND THRESHOLDS: THE FOLLOWING TESTING

PARAMETERS SHALL BE MEASURED DURING TEST AND ACCEPTANCE TESTING.

ERROR PERFORMANCE SHALL BE MEASURED AND RECORDED OVER THE

DURATION OF THE CONTIGUOUS 72 HOUR TESTING INTERVAL AND SHALL BE

MEASURED AND RECORDED PER DEFINITION IN ITU-T.Y.1564.

N. ERROR PERFORMANCE: ERROR PERFORMANCE SHALL BE BETTER THAN THE

FOLLOWING PARAMETER THRESHOLDS TO BE ACCEPTABLE:; AVAILABILITY

SHALL BE GREATER THAN 99.5% OR BETTER.; FRAME LOSS SHALL BE EQUAL TO

ZERO WHEN TESTING AT 1.0 GIGABIT HIGHEST FRAME RATE, AND SHALL MEET

ITU-T.Y.1564 STANDARDS.; JITTER SHALL BE LESS THAN 3 MSEC.; DELAY SHALL

BE BETTER THAN 10 MSEC.

O. MEAN TIME TO LOSS OF BIT COUNT INTEGRITY (MTTLBCI) SHALL BE GREATER

THAN 24 HOURS.

P. ROUNDRIP DELAY (RTD): THE ROUND TRIP DELAY (RTD) FOR THIS DISA

TRANSPORT TRUNK WILL BE MEASURED IN MILLISECONDS FROM THE

CUSTOMERS SERVICE DELIVERY POINT (SDP) SITE-A TO THE CUSTOMERS

SERVICE DELIVERY POINT (SDP) SITE-Z. THE RTD SHALL BE LESS THAN OR EQUAL

TO 11 MILLISECONDS TO EFFECTIVELY SUPPORT THE GOVERNMENT'S MISSION.

THE GOVERNMENT RESERVES THE RIGHT TO ACCEPT A HIGHER RTD ONLY IF

SUPPORTED BY ACTUAL PHYSICAL FIBER DISTANCE BETWEEN THE TWO END

LOCATIONS. ADDITIONALLY THE GOVERNMENT RESERVES THE RIGHT TO REJECT

A PROPOSED PATH IF DEEMED EXCESSIVELY LONG WITHOUT WRITTEN

JUSTIFICATION IN THE PROPOSAL. JUSTIFICATION FOR EXCESSIVE FIBER

MILEAGE COULD BE DIVERSITY/AVOIDANCE REQUIREMENTS, LIMITED

INFRASTRUCTURE, AVAILABLE PROVIDERS, GEOGRAPHIC AND PHYSICAL

LIMITATION. THE GOVERNMENT ACCEPTING AUTHORITY WILL CONFIRM THE

RTD DURING THE TURN-UP AND TEST PHASE AND IF IT DOES NOT ALIGN WITH

THE CONTRACTORS PROPOSAL DISA IE161 WILL NOTIFY DITCO IMMEDIATELY

IN WRITING.

File details come from the government source that posted it.