IQO INQUIRY
FM: PL8211
TO: Contractors
DATE (MM/DD/YYYY): 4/30/2018
SUBJECT: HC101317QA885-0003 Amend: 0003
A. TYPE ACTION: AMEND
1. PURPOSE: THE PURPOSE OF THIS AMENDMENT TO SOLICITATION HC101317QA885 IS
TO:
1. CHANGE THE SERVICE DATE TO BE MET TO 01 SEP 18 SIP;
2. CHANGE Z LOCATION FROM MECHANICSBURG, PA TO FORT BELVOIR, VA.
3. ADD NEW PARAGRAPH 9 AT PURPOSE STATEMENT TO CLARIFY THAT 50 METERS
PHYSICAL SEPARATION REQUIREMENT STILL APPLIES TO THIS REQUIREMENT, BUT THE
DIVERSITY REQUIREMENT IS WAIVED ONLY AS TO THE PART OF THE REQUIREMENT
ROUTE THAT PASSES THROUGH DOWNTOWN PHILADELPHIA, PA.
4. UPDATED CIRCUIT PARAMETERS AND TESTING REQUIREMENTS ATTACHED.
RECAP
1. SUBMIT A QUOTE TO PROVIDE, INSTALL, AND MAINTAIN AN UNPROTECTED OC-48C
LEASED IP BACKBONE TRUNK BETWEEN DISA IE1 PROVIDED CISCO ASR-9010 ROUTER
(UJEWLKH040) (IPT-PEX2) BLDG 120, ROOM 107B, 120 LANSDOWNE ROAD; LAKEHURST
NAVAL AIR CENTER, LAKEHURST, NJ 08733, AND DISA IE1 PROVIDED CISCO ASR-9010
ROUTER (UJEWMEC030) (IPT-PE1) BLDG 2310, ROOM 130, 8575 JOHN J. KINGMAN ROAD, FT
BELVIOR, VA 22060.
A. CONTRACTORS SHALL MEET RTD OF 10 MILLISECONDS
B. VENDOR MUST DELIVER OC-48C SERVICE 2W (UNPROTECTED) FROM COML DEMARC TO
GOVERNMENT SERVICE DELIVERY POINT AT BOTH LOCATIONS.;
C. VENDOR MUST PROVIDE LIGHT LEVEL READINGS (DB LOSS) ON EXTENSION FROM
COMMERCIAL POP TO GOVERNMENT SERVICE DELIVERY POINT (SDP) AT BOTH
LOCATIONS PRIOR TO CIRCUIT TURN UP TO THE GOVERNMENT ENSURING LEVELS ARE
WITHIN SPECS. LIGHT LEVELS MUST BE ADJUSTED TO -5 TO -13.
D. VENDOR MUST CONDUCT WALK-THROUGH SITE SURVEY PRIOR TO INSTALLATION AT
BOTH LOCATIONS.
E. VENDOR MUST CONTACT DISA GOC IP BACKBONE ENGINEERING AND IMPLEMENTATION
GROUP UPON RECEIPT OF A VALID TSO TO ESTABLISH THE COORDINATION AND
ACTIVATION PROCESS. (C) 618-220-8627 (D) 770-8627.
F. VENDOR MUST CONDUCT A SATISFACTORY 24 HOUR END TO END TEST PRIOR TO TURN
OVER TO THE GOVERNMENT FOR ACCEPTANCE TESTING.
G. OC-48C SERVICE MUST PASS A DOCUMENTED SATISFACTORY 24 HOUR END TO END
TEST IAW ITU STANDARD M.2101 PRIOR TO TURN UP TO THE GOVERNMENT.
HC101317QA885-0003
2. EACH CONTRACTOR IS RESPONSIBLE FOR READING AND COMPLYING WITH ALL
TECHNICAL ASPECTS OF THIS SOLICITATION, TO INCLUDE READING AND AGREEING
WITH THE STANDARD PROVISIONS, ATTACHMENTS LISTING SPECIFIC TECHNICAL
REQUIREMENTS, PRICE QUOTE REQUIREMENTS, AND REQUESTED SERVICE DATE.
FAILURE TO READ AND ADHERE TO ANY PORTION OF THE INQUIRY SHALL RENDER THE
QUOTE NON-COMPLIANT AND RESULT IN IT BEING EXCLUDED FROM EVALUATION AND
AWARD.
3. THE SERVICE DATE TO BE MET IS: 01 SEP 18 (SIP). THE GOVERNMENT ASSUMES THAT
CONTRACTORS HAVE CONSIDERED ALL ISSUES THAT MAY IMPACT THE SERVICE DATE.
THE GOVERNMENT MAY CANCEL, TERMINATE, OR REQUEST CONSIDERATION IAW
STANDARD PROVISION 42 FOR FAILURE TO MEET CONTRACTUAL SERVICE DATE OR
COMPLY WITH ANY CONTRACT TERMS OR CONDITIONS.
4. CONTRACTORS SHALL SUBMIT QUOTES IAW STANDARD PROVISION 04. QUOTES SHALL
INCLUDE SUFFICIENT DETAIL FOR EFFECTIVE EVALUATION AND SHOULD NOT SIMPLY
REPHRASE OR RESTATE THE GOVERNMENT REQUIREMENTS. RATHER, THEY MUST
PROVIDE CONVINCING RATIONALE TO ADDRESS HOW THE CONTRACTOR INTENDS
TO MEET THE REQUIREMENT. IN RESPONSE TO THIS SOLICITATION, NO TERMS OR
CONDITIONS PLACED UPON THE GOVERNMENT, NOR ASSUMPTIONS WILL BE ACCEPTED.
RESPONSES TO CONTRACTORS ARE ENCOURAGED TO SUBMIT QUESTIONS AND REQUEST
CLARIFICATIONS OF THE REQUIREMENT (S) BEFORE SUBMITTING QUOTES. QUESTIONS
SHALL BE SUBMITTED TO CONTRACT SPECIALIST AND CONTRACTING OFFICER DURING
THE SOLICITATION PHASE ONLY, AND RESPONSES FOR ALL INTERESTED PARTIES WILL
BE POSTED TO FEDBIZOPPS. . QUOTES MUST BE UPLOADED TO IDEAS AND A COURTESY
COPY MAY BE SENT TO THE FOLLOWING MAILBOX. DISA SCOTT AFB DITCO MAILBOX
VENDOR QUOTES . THIS MAILBOX MAY ALSO BE USED WHEN HAVING ISSUES UPLOADING
QUOTES IN IDEAS.
5. THIS REQUIREMENT MUST BE WORKED IN CONJUNCTION WITH SOLICITATION
HC101317QA905/TSR RU15FEB175129.
6. CONTRACTOR SHALL PROVIDE COLOR POWERPOINT DRAWINGS SHOWING THE ROUTES
FROM THE COMMERCIAL DEMARKS TO THE SUPPORTING CENTRAL OFFICES AND/OR
WIRING CENTERS, ENSURING THE PHYSICAL END TO END DIVERSITY REQUIREMENTS ARE
BEING MET. DRAWINGS MUST INCLUDE SEPARATION DISTANCES, TOTAL FIBER MILES
AND ROUND TRIP DELAY BASED ON ACTUAL DISTANCE IN MILES. REFER TO STANDARD
PROVISION 39 FOR SPECIFIC DOCUMENTATION REQUIREMENTS. SAMPLE DRAWINGS ARE
INCLUDED THE ATTACHMENTS.
7. ESTABLISH TSP: TSP0GKVQT-01
8. THIS REQUIREMENT MUST BE ENGINEERED AND PROVISIONED TOTALLY DIVERSE
END TO END TO GOVERNMENT'S SERVICE DELIVERY POINTS (SDP'S) FROM TSR
RU15FEB175129 (HC101317QA885); MEANING THAT PHYSICAL PATHS ARE TOTALLY
SEPARATE INCLUDING MAN HOLES, CONDUIT, (CENTRAL OFFICE LOCATIONS), AND FIBER
BUILDS. ADDITIONALLY AS A MINIMUM MUST HAVE 50 METERS PHYSICAL SEPARATION
FROM TSR RU15FEB175129.
9. THE DIVERSITY REQUIREMENT STATED ABOVE OF 50 METERS MINIMUM PHYSICAL
SEPARATION FROM TSR RU15FEB175129 IS WAIVED IN DOWNTOWN PHILADELPHIA, PA,
BUT REMAINS IN PLACE FOR THE REST OF THE PATH OF THIS REQUIREMENT.
M. ADDITIONAL INFORMATION:
3. TSR NUMBER: RU15FEB175128D
4. CCSD: XXXXBTE4
Z. DITCO CONTACT:
Christopher OConnor
618-229-9712 christopher.t.oconnor2.civ@mail.mil
Paul A. Heard
DITCO Contracting Officer
Add the following:
LOCATION OF TERMINATION A:
ADDRESS: BLDG 120, 120 Lansdowne Road, Lakehurst NAC, Lakehurst, NJ 08733.
ROOM: 107B
LOCATION: ACC
EXTENSION OF TELECOMMUNICATIONS SERVICE: All facilities between vendor's commercial communications interface point and termination location shall be provided by vendor. All cables shall be run in accordance with local site standards
INTERFACE: INTERFACE: ELECTRICAL: OPTICAL; PHYSICAL: LC;; (PHYSICAL) LC;(ELECTRICAL) OPTICAL
DEMARK: (BLDG) HANGAR 1; 1 LANSDOWNE ROAD; LAKEHURST NAEC, LAKEHURST, NJ, 08733,
TELEPHONE ROOM; N/A FL
NPA/NXX: 732/323
UNIQUE INSTALLATION FACTORS: (1) FIBER CABLE, ON-BASE, SINGLE-MODE, 1310NM,
87CS PERSONNEL
(2) FIBER TERMINATING PATCH PANEL (GFE)(SITE
PROVIDED)
(3) FIBER CABLE X-CONNECT, IN-HOUSE, INSIDE WIRE,
SINGLE-MODE, 1310NM, TELCO
(4) COMMERCIAL FIBER POINT OF PRESENCE
(5) CISCO ASR-9010 ROUTER (GFE)(DISA IE1
PROVIDED) NODE ID:UJEWLKH040
(6) OPTICAL INTERFACE CARD (GFE)(DISA IE1
PROVIDED) OC48C /PO0/0/0
RESERVATION: 17786.
IP ADDRESS: 33.20.15.82
SUBNET MASK: 255.255.255.252
(7) FIBER CABLE, ON-BASE, SINGLE-MODE, 1310NM,
87CS PERSONNEL
AMPLIFYING INFO:
A. 87CS PERSONNEL ARE RESPONSIBLE FOR INSTALLATION AND MAINTENANCE OF SINGLE MODE FIBER FROM
LINE SIDE OF SITE PROVIDED FIBER TERMINATING PATCH PANEL BLDG 120, ROOM 107B TO LINE SIDE OF SITE
PROVIDED FIBER TERMINATING PATCH PANEL HANGAR 1, TELEPHONE ROOM.
B. VENDOR IS RESPONSIBLE FOR INSTALLATION AND MAINTENANCE OF SINGLE MODE FIBER FROM DROP SIDE OF
SITE PROVIDED FIBER PATCH PANEL HANGAR 1, TELEPHONE ROOM TO DROP SIDE OF COMMERCIAL FIBER POINT
OF PRESENCE FIBER DISTRIBUTION PANEL HANGAR 1, TELEPHONE ROOM. COORDINATE TYPE CONNECTORS FOR
TERMINATION TO DISA PROVIDED PATCH PANEL.
C. VENDOR MUST COORDINATE WITH GOVERNMENT SITE PERSONNEL TO CONDUCT WALK THROUGH SITE
SURVEY FOR EXACT CABLE FT. FROM SITE PROVIDED FIBER TERMINATING PATCH PANEL HANGAR 1, TELEPHONE
ROOM TO COMMERCIAL FIBER POINT OF PRESENCE HANGAR 1, TELEPHONE ROOM.
D. VENDOR MUST PROVIDE FIBER STRANDS FROM SITE PROVIDED FIBER PATCH PANEL TO COMMERCIAL DEMARC
LOCATION WITHOUT SPLICING AND OR USE OF CONNECTORS TO CONNECT 2 OR MORE FIBER STRANDS MEANING
THE FIBER CANNOT BE BROKEN IN THE MIDDLE AND MUST BE CONTINUOUS.
E. VENDOR MUST SCHEDULE/COORDINATE WITH POC'S LISTED ON THIS ORDER 72 HOURS IN ADVANCE PRIOR TO
SITE SURVEYS OR INSTALLATIONS.
F. DISA IE4 IS RESPONSIBLE FOR INSTALLATION AND GSM-O FOR MAINTENANCE OF CISCO ASR-9010 ROUTER, OPTICAL INTERFACE CARD BLDG 120, ROOM 107B.
G. DISA IE4 IS RESPONSIBLE FOR INSTALLATION AND GSM-O FOR SINGLE MODE FIBER FROM OPTICAL INTERFACE
CARD INSTALLED IN CISCO ASR-9010 ROUTER TO DROP SIDE OF DISA IE1 PROVIDED FIBER TERMINATING PATCH
PANEL INSTALLED IN THE CISCO ASR-9010 ROUTER. COORDINATE TYPE OF CONNECTORS.
H. VENDOR IS RESPONSIBLE FOR INSTALLATION AND MAINTENANCE OF SINGLE MODE FIBER FROM LINE SIDE OF
DISA IE1 PROVIDED FIBER TERMINATING PATCH PANEL INSTALLED IN CISCO ASR-9010 ROUTER SUITE
(UJEWLKH040) BLDG 120, ROOM 107B TO DROP SIDE OF SITE PROVIDED FIBER PATCH PANEL BLDG 120, ROOM
107B. COORDINATE TYPE CONNECTORS FOR TERMINATION TO DISA IE1 PROVIDED PATCH PANEL. COORDINATE
WITH 87CS PERSONNEL FOR TYPE CONNECTORS AND FIBER TERMINATION ASSIGNMENTS AT SITE PATCH PANEL
BLDG 120, ROOM 107B CORRESPONDING TO FIBER PAIR ASSIGNMENTS AT SITE PROVIDED FIBER PATCH PANEL
HANGAR 1, TELEPHONE ROOM.
I. VENDOR MUST PROVIDE FIBER STRANDS FROM CISCO ASR-9010 ROUTER SUITE FIBER PATCH PANEL TO SITE
PROVIDED FIBER PATCH PANEL WITHOUT SPLICING AND OR USE OF CONNECTORS TO CONNECT 2 OR MORE
FIBER
STRANDS MEANING THE FIBER CANNOT BE BROKEN IN THE MIDDLE AND MUST BE CONTINUOUS.
J. CIRCUIT MUST BE TAGGED WITH LOCAL CIRCUIT ID AND LONG HAUL CIRCUIT NO. AT LINE SIDE OF DISA IE1
PROVIDED FIBER TERMINATING PATCH PANEL BLDG 120, ROOM 107B AND AT DROP SIDE OF SITE PROVIDED FIBER
INSIDE WIRE INSTALLATION / MAINTENANCE REQUIRED: CPIWI-YES/CPIWM-YES
CONTACT: (PMRY POC) JONATHAN T OKEEFE
(UNCLASS USER) JONATHAN.OKEEFE@US.AF.MIL
(CMCL) 609-754-2978
(ALT POC) CHRISTOPHER S KAILIS
(UNCLASS ORG) CIRCUIT_ACTIONS@US.AF.MIL
(UNCLASS USER) CHRISTOPHER.KAILIS@US.AF.MIL
(CMCL) 609-754-4847
(DSN) 650-4847
Add the following:
LOCATION OF TERMINATION B:
ADDRESS: (BLDG) 2310; 8575 JOHN J. KINGMAN RD, FORT BELVOIR, VA 22060
ROOM: 130; 1 FL
LOCATION: BCC
EXTENSION OF TELECOMMUNICATIONS SERVICE: All facilities between vendor's commercial communications interface point and termination location shall be provided by vendor. All cables shall be run in accordance with local site standards
INTERFACE: INTERFACE: ELECTRICAL: OPTICAL; PHYSICAL: LC;; (PHYSICAL) LC; (ELECTRICAL) OPTICAL
DEMARK: (BLDG) 2310
(RM) 130
(FL) 1
8575 J.J. KINGMAN ROAD
FORT BELVOIR, VA 22060
NPA/NXX: 703/806
UNIQUE INSTALLATION FACTORS: (1) FIBER CABLE X-CONNECT, IN-HOUSE, INSIDE WIRE, SINGLE-MODE, 1310NM, TELCO
(2) TELCO MULTIPLEX (COMMERCIAL FIBER POINT OF PRESENCE) COMMERCIAL CARRIER SYSTEM (LOCAL
EXCHANGE CARRIER)
(3) NODE ID: UJEWBEL030
(4) PORT: 1/0/2
(5) IP ADDRESS: 33.20.15.81/30
AMPLIFYING INFO:
A. VENDOR IS RESPONSIBLE FOR INSTALLATION AND MAINTENANCE OF THE SERVICE FROM THE LINE SIDE OF
THE DISA IE1 PROVIDED FIBER TERMINATING PATCH PANEL INSTALLED IN THE CISCO ASR-9010 ROUTER SUITE
(UJEWBEL030) BLDG 2310, RM 130 TO THE DROP SIDE OF THE COMMERCIAL FIBER POINT OF PRESENCE FIBER
DISTRIBUTION PANEL BLDG 2310, RM 130 USING SINGLE MODE FIBER. COORDINATE TYPE CONNECTORS TO BE
USED FOR TERMINATION TO THE DISA PROVIDED PATCH PANEL.
B. VENDOR MUST COORDINATE WITH GOVERNMENT SITE PERSONNEL TO CONDUCT WALK THROUGH SITE
SURVEYS FOR EXACT CABLE FT. FROM THE DISA PROVIDED FIBER TERMINATING PATCH PANEL INSTALLED IN THE
CISCO ASR-9010 ROUTER SUITE BLDG 2310, RM 130 TO THE COMMERCIAL FIBER POINT OF PRESENCE BLDG 2310, RM 130.
C. VENDOR MUST PROVIDE FIBER STRANDS FROM THE DISA PROVIDED FIBER PATCH PANEL INSTALLED IN THE
CISCO ASR-9010 ROUTER TO THE COMMERCIAL DEMARC LOCATION WITHOUT SPLICING AND OR USE OF
CONNECTORS TO CONNECT 2 OR MORE FIBER STRANDS MEANING THE FIBER CANNOT BE BROKEN IN THE MIDDLE
AND MUST BE CONTINUOUS.
D. VENDOR MUST SCHEDULE/COORDINATE WITH THE POC'S LISTED ON THIS ORDER 72 HOURS IN ADVANCE PRIOR
TO SITE SURVEYS OR INSTALLATIONS.
E. DISA IE4 IS RESPONSIBLE FOR INSTALLATION AND GSM-O FOR MAINTENANCE OF THE CISCO ASR-9010 ROUTER, OPTICAL INTERFACE CARD BLDG 2310, RM 130.
F. DISA IE4 IS RESPONSIBLE FOR INSTALLATION AND GSM-O FOR SERVICE FROM THE INTERFACE CARD
INSTALLED IN THE ROUTER TO THE DROP SIDE OF THE DISA IE1 PROVIDED FIBER TERMINATING PATCH PANEL
INSTALLED IN THE CISCO ASR-9010 SUITE, USING SINGLE-MODE FIBER JUMPERS. COORDINATE TYPE OF
CONNECTORS.
G. VENDOR IS RESPONSIBLE FOR INSTALLATION AND MAINTENANCE OF THE SERVICE FROM THE LINE SIDE OF
THE DISA IE1 PROVIDED FIBER TERMINATING PATCH PANEL INSTALLED IN THE CISCO ASR-9010 ROUTER SUITE
(UJEWBEL030) BLDG 2310, RM 130 TO THE DROP SIDE OF THE COMMERCIAL FIBER POINT OF PRESENCE FIBER
DISTRIBUTION PANEL BLDG 2310, RM 130 USING SINGLE MODE FIBER. COORDINATE TYPE CONNECTORS TO BE
USED FOR TERMINATION TO THE DISA PROVIDED PATCH PANEL.
H. THE CIRCUIT MUST BE TAGGED WITH THE LOCAL CIRCUIT ID AND LONG-HAUL CIRCUIT NO. AT THE LINE SIDE OF
THE DISA PROVIDED FIBER TERMINATING PATCH PANEL BLDG 2310, RM 130 AND AT THE DROP SIDE OF THE
VENDOR'S FIBER DISTRIBUTION PANEL INSTALLED IN THEIR COMMERCIAL SUITE. ADDITIONALLY, VENDOR MUST
SHOW SITE PERSONNEL LISTED ON THIS ORDER THE EXACT TERMINATION POINT WHEN SERVICE IS COMPLETE.
INSIDE WIRE INSTALLATION / MAINTENANCE REQUIRED: CPIWI-YES/CPIWM-YES
CONTACT: (PRMY POC) TECH CONTROL
EMAIL: USARMY.BELVOIR.NETCOM.LIST.596SIGCO-TECH-CONTROL-FACILITY-STAFF@MAIL.MIL
USARMY.BELVOIR.NETCOM.MBX.596SIGCO-TECH-CONTROL-FACILITY STAFF@MAIL.MIL
D655-2030
C703-805-2030
(ALT POC) DARRIAN OWENS
(UNCLASS EMAIL) DARRIAN.L.OWENS.MIL@MAIL.MIL;
(DSN) 656-5697/D655-2030
(CMCL) 703-806-5690
C703-805-2030
EMAIL: USARMY.BELVOIR.NETCOM.LIST.596SIGCO-TECH-CONTROL-FACILITY-STAFF@MAIL.MIL
USARMY.BELVOIR.NETCOM.MBX.596SIGCO-TECH-CONTROL-FACILITY-STAFF@MAIL.MIL