HC101317QA070-0002.v0.pdf
PDF 38 KB Posted
- Attached to
- SOLICITATION HC101317QA069-0002 HAS BEEN AMENDED
- Solicitation number
- HC101317QA070
- Issued by
-
Defense Information Systems Agency
About this file
Not Listed
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
IQO INQUIRY
FM: PL8211
TO: Contractors
DATE (MM/DD/YYYY): 7/13/2017
SUBJECT: HC101317QA070-0002 Amend: 0002
A. TYPE ACTION: ADMIN AMEND
1. PURPOSE: ********* SOLICITATION HC101317QA069-0002 HAS BEEN
AMENDED TO CORRECT MAYPORT COMMERCIAL DEMARCATION ADDRESS TO (BLDG)
2276; (RM) BCO ROOM; 2276 OLD MAINE STREET; MAYPORT NAVAL STATION, FL,
32228 AND (BLDG) 919; (RM) TELCO ROOM; (FL) 1; 919 LANGLEY STREET;
JACKSONVILLE NAS, FL, 32212. REVISED UNIQUE INSTALL FACTS AND
AMPLIFYING INFO - REMOVING SITE PROVIDED PATCH PANELS AND ON BASE
FIBER CABLE. THE NEW QUOTE DUE DATE IS 26 JULY 2017. ALL ELSE REMAINS
THE SAME. *********
1. SUBMIT A QUOTE TO PROVIDE, INSTALL AND MAINTAIN A 1.0GB ETHERNET
SERVICE BETWEEN (BLDG) 2276; (RM) 38; (FL) 1; 1488 MASSEY AVENUE;
MAYPORT NAVAL STATION, FL, 32228 AND (BLDG) 919; (RM) TELCO ROOM; (FL)
1; 919 LANGLEY STREET; JACKSONVILLE NAS, FL, 32212.
2. ESTABLISH TSP: TSP0GG9EW-01 AND NSS: Y5
3. CONTRACTORS SHALL MEET THE RTD OF 10 MILLISECONDS. VENDOR IS
RESPONSIBLE FOR FIBER JUMPER IN LOCATION 3.A. (MAYPORT BCO ROOM).
4. EACH CONTRACTOR IS RESPONSIBLE FOR READING AND COMPLYING WITH ALL
TECHNICAL ASPECTS OF THIS SOLICITATION, TO INCLUDE READING AND
AGREEING WITH THE STANDARD PROVISIONS, ATTACHMENTS LISTING SPECIFIC
TECHNICAL REQUIREMENTS, PRICE QUOTE REQUIREMENTS, AND REQUESTED
SERVICE DATE. FAILURE TO READ AND ADHERE TO ANY PORTION OF THE
INQUIRY SHALL RENDER THE QUOTE NON-COMPLIANT AND RESULT IN IT BEING
EXCLUDED FROM EVALUATION AND AWARD.
5. THE SERVICE DATE TO BE MET IS: 06 JUL 17 (SIP). THE GOVERNMENT
ASSUMES THAT CONTRACTORS HAVE CONSIDERED ALL ISSUES THAT MAY IMPACT
THE SERVICE DATE. THE GOVERNMENT MAY CANCEL, TERMINATE, OR REQUEST
CONSIDERATION IAW STANDARD PROVISION 42 FOR FAILURE TO MEET
CONTRACTUAL SERVICE DATE OR COMPLY WITH ANY CONTRACT TERMS OR
CONDITIONS.
6. CONTRACTORS SHALL SUBMIT QUOTES IAW STANDARD PROVISION 04. QUOTES
SHALL INCLUDE SUFFICIENT DETAIL FOR EFFECTIVE EVALUATION AND SHOULD
NOT SIMPLY REPHRASE OR RESTATE THE GOVERNMENT REQUIREMENTS. RATHER,
THEY MUST PROVIDE CONVINCING RATIONALE TO ADDRESS HOW THE CONTRACTOR
INTENDS TO MEET THE REQUIREMENT. IN RESPONSE TO THIS SOLICITATION, NO
TERMS OR CONDITIONS PLACED UPON THE GOVERNMENT, NOR ASSUMPTIONS WILL
HC101317QA070-0002
BE ACCEPTED. CONTRACTORS ARE ENCOURAGED TO SUBMIT QUESTIONS AND
REQUEST CLARIFICATIONS OF THE REQUIREMENT (S) BEFORE SUBMITTING
QUOTES. QUESTIONS SHALL BE SUBMITTED TO CONTRACT SPECIALIST AND
CONTRACTING OFFICER DURING THE SOLICITATION PHASE ONLY, AND RESPONSES
FOR ALL INTERESTED PARTIES WILL BE POSTED TO FEDBIZOPPS.
7. THIS REQUIREMENT MUST BE WORKED IN CONJUNCTION WITH SOLICITATION
HC101317QA0369 / TSR RU20OCT168393 AND MUST BE ENGINEERED AND
PROVISIONED TOTALLY DIVERSE END TO END FROM THE GOVERNMENT SERVICE
DELIVERY POINTS (SDP) FROM HC101317QA0369 / TSR RU20OCT168393;
MEANING THE PHYSICAL PATHS ARE TOTALLY SEPARATE INCLUDING MAN HOLES,
CONDUIT, CENTRAL OFFICE LOCATIONS, AND FIBER BUILDS. ADDITIONALLY AS
A MINIMUM MUST HAVE 50 METERS PHYSICAL SEPARATION FROM HC101317QA0369
/ TSR RU20OCT168393.
8. CONTRACTOR SHALL PROVIDE COLOR POWERPOINT DRAWINGS SHOWING THE
ROUTES FROM THE COMMERCIAL DEMARKS TO THE SUPPORTING CENTRAL OFFICES
AND/OR WIRING CENTERS, ENSURING THE PHYSICAL END TO END DIVERSITY
REQUIREMENTS ARE BEING MET. DRAWINGS MUST INCLUDE SEPARATION
DISTANCES, TOTAL FIBER MILES AND ROUND TRIP DELAY BASED ON ACTUAL
DISTANCE IN MILES. REFER TO STANDARD PROVISION 39 FOR SPECIFIC
DOCUMENTATION REQUIREMENTS. SAMPLE DRAWINGS ARE INCLUDED THE
ATTACHMENTS.
9. PRE AWARD SITE SURVEYS ARE AUTHORIZED (AT CONTRACTOR EXPENSE) WITH
LOCAL POCS AT EACH GOVERNMENT SITE. IT IS HIGHLY RECOMMENDED THAT AT
A MINIMUM, CONTRACTORS CONDUCT PHONE SURVEYS TO ADEQUATELY ASSESS THE
MAGNITUDE OF THE WORK TO BE PERFORMED IN DETERMINING THEIR PRICE
STRATEGY.
10. ********SEE UNIQUE INSTALL FACTORS*******
M. ADDITIONAL INFORMATION:
3. TSR NUMBER: RU20OCT168394A
4. CCSD: DBH3BWT2
Z. DITCO CONTACT:
Andrew Fernandez 618-229-9414 andrew.r.fernandez.civ@mail.mil
Paul A. Heard
DITCO Contracting Officer
Unless otherwise specified, all other terms and conditions are unchanged.
Paragraph V.QUOTE DUE DATE AND TIME change from:
Mar 2, 2017 4:00:00 PM CST
To:
Jul 26, 2017 3:00:00 PM CDT
Attachments Begin After This Page.
HC101317QA070-0002- ATTACHMENT 1- UNIQUE INSTALL FACTS
UNIQUE INST FACT: BACKBONE WILL TERMINATE ON UJEWMPT030,
PORT: GI-0/2/1/0, NODE IP: 33.20.14.198, SUBNET MASK:
255.255.255.252
(1) OPTICAL INTERFACE CARD (GFE)(DISA IE1 PROVIDED)
(2) FIBER CABLE X-CONNECT, IN-HOUSE, INSIDE WIRE,
SINGLE-MODE, 1310NM, DISA IE4
(3) FIBER TERMINATING PATCH PANEL (GFE)(DISA IE1
PROVIDED)
RACK/SHELF/PORT - TBD
(4) FIBER CABLE X-CONNECT, IN-HOUSE, INSIDE WIRE,
SINGLE-MODE, 1310NM, TELCO
(5) FIBER TERMINATING PATCH PANEL (GFE)(SITE PROVIDED)
RACK/SHELF/PORT - TBD
(6) FIBER CABLE, ON-BASE, SINGLE-MODE, 1310NM,
NCSTI N9 PERSONNEL
AMPLIFYING INFO:
A. DISA IE4 IS RESPONSIBLE FOR INSTALLATION AND GSM-O
FOR MAINTENANCE OF CISCO ASR-9006 ROUTER, OPTICAL
INTERFACE CARD BLDG 2276, BCO ROOM.
B. DISA IE4 IS RESPONSIBLE FOR INSTALLATION AND GSM-O
FOR SINGLE MODE FIBER FROM OPTICAL INTERFACE CARD
INSTALLED IN CISCO ASR-9006 ROUTER TO DROP SIDE OF
DISA IE1 PROVIDED FIBER TERMINATING PATCH PANEL
INSTALLED IN CISCO ASR-9006 ROUTER. COORDINATE TYPE
OF CONNECTORS.
C. VENDOR IS RESPONSIBLE FOR INSTALLATION AND
MAINTENANCE OF SINGLE MODE FIBER FROM LINE SIDE OF
DISA IE1 PROVIDED FIBER TERMINATING PATCH PANEL
INSTALLED IN CISCO ASR-9006 ROUTER SUITE
(UJEWMPT030) BLDG 2276, BCO ROOM TO DROP SIDE OF
COMMERCIAL FIBER POINT OF PRESENCE FIBER
DISTRIBUTION PANEL BLDG 2276, BCO ROOM. COORDINATE
TYPE CONNECTORS FOR TERMINATION TO DISA PROVIDED
PATCH PANEL.;
D. VENDOR MUST PROVIDE FIBER STRANDS FROM CISCO ROUTER
SUITE FIBER PATCH PANEL TO SITE PROVIDED FIBER
PATCH PANEL WITHOUT SPLICING AND OR USE OF
CONNECTORS TO CONNECT 2 OR MORE FIBER STRANDS
MEANING THE FIBER CANNOT BE BROKEN IN THE MIDDLE
AND MUST BE CONTINUOUS.
E. CIRCUIT MUST BE
(C) INSIDE WIRE INSTL/MAINT: CPIWI-YES/CPIWM-YES
(D) TERM: 2W
(E) INTERFACE: (PHYSICAL) LC; (ELECTRICAL) OPTICAL
File details come from the government source that posted it. Updated .