IQO INQUIRY
FM: PL8211
TO: Contractors
DATE (MM/DD/YYYY): 7/13/2017
SUBJECT: HC101317QA069-0002 Amend: 0002
A. TYPE ACTION: ADMIN AMEND
1. PURPOSE: ********* SOLICITATION HC101317QA069-0002 HAS BEEN
AMENDED TO REMOVE DISN EQUIPMENT AT JKSVLNAS - MCDLLAFB. CORRECT
SECOND COMMERCIAL DEMARK ADDRESS TO READ: BLDG. 570, ROOM S-215 (SI1),
SECOND FLOOR, 7115 SOUTH BOUNDARY BLVD, MACDILL AFB, FL 33621-
1454/CC2. ADD INTERFACE; INSIDE WIRE, UNIQUE INSTALL FACTS AND REMOVE
TRANSPORT MEDIUM ENTRY. THE NEW QUOTE DUE DATE IS 26 JULY 2017. ALL
ELSE REMAINS THE SAME. *********
1. SUBMIT A QUOTE TO PROVIDE, INSTALL AND MAINTAIN A 1.0GB ETHERNET
SERVICE BETWEEN (BLDG) 2276; (RM) BCO; 3604 MAYPORT ROAD; MAYPORT
NAVAL STATION, FL, 32228 AND (BLDG) 570, (RM) S-215 (SI1), (FL) 2ND,
7115 SOUTH BOUNDARY BLVD, MACDILL AFB, FL 33621-1454.
2. ESTABLISH TSP: TSP0GG9DA-01 AND NSS: Y5.
3. CONTRACTORS SHALL MEET THE RTD OF 10 MILLISECONDS.
4. EACH CONTRACTOR IS RESPONSIBLE FOR READING AND COMPLYING WITH ALL
TECHNICAL ASPECTS OF THIS SOLICITATION, TO INCLUDE READING AND
AGREEING WITH THE STANDARD PROVISIONS, ATTACHMENTS LISTING SPECIFIC
TECHNICAL REQUIREMENTS, PRICE QUOTE REQUIREMENTS, AND REQUESTED
SERVICE DATE. FAILURE TO READ AND ADHERE TO ANY PORTION OF THE INQUIRY
SHALL RENDER THE QUOTE NON-COMPLIANT AND RESULT IN IT BEING EXCLUDED
FROM EVALUATION AND AWARD.
5. THE SERVICE DATE TO BE MET IS: 06 JUL 17 (SIP). THE GOVERNMENT
ASSUMES THAT CONTRACTORS HAVE CONSIDERED ALL ISSUES THAT MAY IMPACT
THE SERVICE DATE. THE GOVERNMENT MAY CANCEL, TERMINATE, OR REQUEST
CONSIDERATION IAW STANDARD PROVISION 42 FOR FAILURE TO MEET
CONTRACTUAL SERVICE DATE OR COMPLY WITH ANY CONTRACT TERMS OR
CONDITIONS.
6. CONTRACTORS SHALL SUBMIT QUOTES IAW STANDARD PROVISION 04. QUOTES
SHALL INCLUDE SUFFICIENT DETAIL FOR EFFECTIVE EVALUATION AND SHOULD
NOT SIMPLY REPHRASE OR RESTATE THE GOVERNMENT REQUIREMENTS. RATHER,
THEY MUST PROVIDE CONVINCING RATIONALE TO ADDRESS HOW THE CONTRACTOR
INTENDS TO MEET THE REQUIREMENT. IN RESPONSE TO THIS SOLICITATION, NO
TERMS OR CONDITIONS PLACED UPON THE GOVERNMENT, NOR ASSUMPTIONS WILL
BE ACCEPTED. CONTRACTORS ARE ENCOURAGED TO SUBMIT QUESTIONS AND
REQUEST CLARIFICATIONS OF THE REQUIREMENT (S) BEFORE SUBMITTING
HC101317QA069-0002
QUOTES. QUESTIONS SHALL BE SUBMITTED TO CONTRACT SPECIALIST AND
CONTRACTING OFFICER DURING THE SOLICITATION PHASE ONLY, AND RESPONSES
FOR ALL INTERESTED PARTIES WILL BE POSTED TO FEDBIZOPPS.
7. THIS REQUIREMENT MUST BE WORKED IN CONJUNCTION WITH SOLICITATION
HC101317QA070 / TSR RU20OCT168394 AND MUST BE ENGINEERED AND
PROVISIONED TOTALLY DIVERSE END TO END FROM THE GOVERNMENT SERVICE
DELIVERY POINTS (SDP) FROM TSR HC101317QA070 / TSR RU20OCT168394 ;
MEANING THE PHYSICAL PATHS ARE TOTALLY SEPARATE INCLUDING MAN HOLES,
CONDUIT, CENTRAL OFFICE LOCATIONS, AND FIBER BUILDS. ADDITIONALLY AS
A MINIMUM MUST HAVE 50 METERS PHYSICAL SEPARATION FROM TSR
HC101317QA070 / TSR RU20OCT168394.
8. CONTRACTOR SHALL PROVIDE COLOR POWERPOINT DRAWINGS SHOWING THE
ROUTES FROM THE COMMERCIAL DEMARKS TO THE SUPPORTING CENTRAL OFFICES
AND/OR WIRING CENTERS, ENSURING THE PHYSICAL END TO END DIVERSITY
REQUIREMENTS ARE BEING MET. DRAWINGS MUST INCLUDE SEPARATION
DISTANCES, TOTAL FIBER MILES AND ROUND TRIP DELAY BASED ON ACTUAL
DISTANCE IN MILES. REFER TO STANDARD PROVISION 39 FOR SPECIFIC
DOCUMENTATION REQUIREMENTS. SAMPLE DRAWINGS ARE INCLUDED THE
ATTACHMENTS.
9. PRE AWARD SITE SURVEYS ARE AUTHORIZED (AT CONTRACTOR EXPENSE) WITH
LOCAL POCS AT EACH GOVERNMENT SITE. IT IS HIGHLY RECOMMENDED THAT AT
A MINIMUM, CONTRACTORS CONDUCT PHONE SURVEYS TO ADEQUATELY ASSESS THE
MAGNITUDE OF THE WORK TO BE PERFORMED IN DETERMINING THEIR PRICE
STRATEGY.
10. *****SEE UNIQUIE INSTALL FACTORS*****
M. ADDITIONAL INFORMATION:
3. TSR NUMBER: RU20OCT168393A
4. CCSD: DBH3BVT2
Z. DITCO CONTACT:
Andrew Fernandez 618-229-9414 andrew.r.fernandez.civ@mail.mil
Paul A. Heard
DITCO Contracting Officer
Unless otherwise specified, all other terms and conditions are unchanged.
Paragraph V.QUOTE DUE DATE AND TIME change from:
Mar 2, 2017 4:00:00 PM CST
To:
Jul 26, 2017 3:00:00 PM CDT
Attachments Begin After This Page.
HC101317QA069-0002- ATTACHMENT 1- UNIQUE INSTALL FACTS
(A) COMMERCIAL FIBER POINT OF PRESENCE
(B) UNIQUE INST FACT:
(1) COMMERCIAL FIBER POINT OF PRESENCE
(2) FIBER CABLE X-CONNECT, IN-HOUSE, INSIDE WIRE,
SINGLE-MODE, 1310NM, TELCO
AMPLIFYING INFO:
A. VENDOR IS RESPONSIBLE FOR INSTALLATION AND
MAINTENANCE OF SINGLE MODE FIBER FROM DROP SIDE OF
COMMERCIAL FIBER POINT OF PRESENCE [FIBER
DISTRIBUTION PANEL (FDP)] BLDG 570, ROOM S-215 TO
LINE SIDE OF DISA IE1 PROVIDED FIBER TERMINATING
PATCH PANEL INSTALLED IN CISCO ROUTER SUITE
(UJEWMAC030) BLDG 570, ROOM S-215. TERMINATE WITH
"SC" CONNECTORS TO DISA PROVIDED FIBER TERMINATING
PATCH PANEL.
B. VENDOR MUST PROVIDE FIBER STRANDS FROM THEIR POINT
OF PRESENCE TO CISCO ROUTER SUITE WITHOUT SPLICING
AND OR USE OF CONNECTORS TO CONNECT 2 OR MORE FIBER
STRANDS MEANING FIBER CANNOT BE BROKEN IN THE
MIDDLE AND MUST BE CONTINUOUS.
C. LENGTH OF SINGLE MODE FIBER JUMPERS REQUIRED WILL
BE BASED ON LOCATION OF THEIR POINT OF PRESENCE.
D. CIRCUIT MUST BE TAGGED WITH VENDOR'S CIRCUIT ID AS
APPLICABLE AT DROP SIDE OF THEIR POINT OF PRESENCE
(FIBER DISTRIBUTION PANEL) BLDG 570, ROOM S-215.
ADDITIONALLY, VENDOR MUST SHOW SITE PERSONNEL
LISTED ON THIS ORDER THE EXACT TERMINATION POINT
WHEN SERVICE IS COMPLETE.
(D) COML ACCESS: WILL NOT LEAK - CAT 6
(E) INTERFACE: (PHYSICAL) SINGLE-MODE 1310NM, SC CONNECTORS;
(ELECTRICAL) OPTICAL.
A) FIBER TERMINATING PATCH PANEL (GFE)(DISA IE1 PROVIDED)
OPTICAL INTERFACE CARD (GFE)(DISA IE1 PROVIDED)
CISCO ASR-9010 ROUTER (GFE)(DISA IE1 PROVIDED)
(B) INSIDE WIRE INSTL/MAINT: CPIWI-YES/CPIWM-YES
(C) TERM: 2W
(D) COML ACCESS: WILL NOT LEAK - CAT 6
(E) INTERFACE: (PHYSICAL) LC; (ELECTRICAL) OPTICAL
(F) UNIQUE INST FACT: BACKBONE WILL TERMINATE ON UJEWMAC030,
PORT:
GI-0/2/1/17, NODE IP: 33.20.14.189, SUBNET MASK:
255.255.255.252
(1) FIBER CABLE X-CONNECT, IN-HOUSE, INSIDE WIRE,
SINGLE-MODE, 1310NM, TELCO
(2) FIBER TERMINATING PATCH PANEL (GFE)
(DISA IE1 PROVIDED)
RACK/SHELF/PORT - TBD
(3) FIBER CABLE X-CONNECT, IN-HOUSE, INSIDE WIRE,
SINGLE-MODE, 1310NM, DISA IE4
(4) OPTICAL INTERFACE CARD (GFE)(DISA IE1 PROVIDED)
AMPLIFYING INFO:
A. VENDOR IS RESPONSIBLE FOR INSTALLATION AND
MAINTENANCE OF SINGLE MODE FIBER FROM COMMERCIAL
FIBER POINT OF PRESENCE FIBER DISTRIBUTION PANEL
BLDG 570, ROOM S-215 TO LINE SIDE OF DISA IE1
PROVIDED FIBER TERMINATING PATCH PANEL INSTALLED IN
CISCO ASR-9010 ROUTER SUITE (UJEWMAC030) BLDG 570,
ROOM S-215. COORDINATE TYPE CONNECTORS FOR
TERMINATION TO DISA PROVIDED PATCH PANEL.
B. CIRCUIT MUST BE TAGGED WITH LOCAL CIRCUIT ID AND
LONG HAUL CIRCUIT NO. AS APPLICABLE AT DROP SIDE OF
VENDOR'S FIBER DISTRIBUTION PANEL INSTALLED IN
THEIR EQUIPMENT SUITE AND AT LINE SIDE OF DISA
PROVIDED FIBER TERMINATING PATCH PANEL BLDG 570,
ROOM S-215. ADDITIONALLY, VENDOR MUST SHOW SITE
PERSONNEL LISTED ON THIS ORDER THE EXACT
TERMINATION POINT WHEN SERVICE IS COMPLETE.
C. DISA IE4 IS RESPONSIBLE FOR INSTALLATION AND GSM-O
FOR MAINTENANCE OF SINGLE MODE FIBER FROM DROP SIDE
OF DISA IE1 PROVIDED FIBER TERMINATING PATCH PANEL
INSTALLED IN CISCO ASR-9010 ROUTER SUITE TO OPTICAL
INTERFACE CARD INSTALLED IN CISCO ASR-9010 ROUTER.
TERMINATE "SC" TO "LC" CONNECTORS.
D. DISA IE4 IS RESPONSIBLE FOR INSTALLATION AND GSM-O
FOR MAINTENANCE OF CISCO ASR-9010 ROUTER, OPTICAL
INTERFACE CARD BLDG 570, ROOM S-215.