ARMY TM 38-400
NAVY NAVSUP PUB 572
AIR FORCE AFMAN 23-210
MARINE CORPS MCO 4450-14
DEFENSE LOGISTICS AGENCY DLAM 4145.12
JOINT SERVICE MANUAL (JSM) FOR STORAGE AND
MATERIALS HANDLING
Approved for public release; Distribution is unlimited.
DEPARTMENTS OF THE ARMY, THE NAVY, THE AIR FORCE,
AND THE DEFENSE LOGISTICS AGENCY
April 1994
By Order the Secretaries of the Army, the Navy, the Air Force, and the Director, Defense Logistics Agency
Official:
EDWARD A. PARDINI,
Colonel, USAF Director of Information Management
R.A. TIEBOUT
Lieutenant General, U.S. Marine Corps Deputy Chief of Staff for Installations and Logistics
GORDON R. SULLIVAN
General, United States Army Chief of Staff
MERRILL A. McPEAK, General, USAF Chief of Staff
R.A. ARCHER,
Captain, SC, USN Deputy Commander for Fleet Logistics Operations
GARY C. TUCKER
Colonel, USA Staff Director, Administration, DLA
Distribution:
Army:
Navy:
Air Force: F Marine Corps: MARCORPS PCN 10205650400
Reprinted for stock only 11Sep95.
TM 38-400
NAVSUP PUB 572
AFMAN 23-210
MCO 4450.14
DLAM 4145.12
RMY HEADQUARTERS
No. 38-400
NAVSUP PUB DEPARTMENTS OF THE ARMY, THE NAVY,
No.572
AIR FORCE THE AIR FORCE, AND THE DEFENSE
No. 23-210 No. 4450-14 LOGISTICS AGENCY
DLA
No.4145.12 Washington, DC, 12 April 1994
JOINT SERVICE MANUAL (JSM) FOR STORAGE AND MATERIALS
HANDLING
REPORTING ERRORS AND RECOMMENDING IMPROVEMENTS
You can help improve this manual. If you find any mistakes or you know of a way to improve the procedures let us know.
Mail your letter or DA Form 2028 (Recommended Changes to Publications and Blank Forms) directly to Director, U.S.
Army Materiel Command, Packaging, Storage, and Containerization Center, ATTN: SDSTO-TM, Tobyhanna, PA 18466-5097. A reply will be furnished you.
Page
CHAPTER 1. GENERAL............................................. 1-1
CHAPTER 2. STORAGE SPACE MANAGEMENT............................ 2-1
Section I. Types of Storage Space.............................. 2-1 Section II. Space Requirement Factors........................... 2-15 Section III. Determination of Storage Requirements (DOSSR) Method. 2-25 Section IV. Planning the Storage Layout......................... 2-25 Section V. Space Control and Reporting......................... 2-44
CHAPTER 3. STORAGE PROCEDURES................................... 3-1
Section I. Receiving........................................... 3-1 Section II. Shipping............................................ 3-14 Section III. Stock Location...................................... 3-16 Section IV. Pest Management..................................... 3-24 Section V. Inventory........................................... 3-27 Section VI. Care of Supplies in Storage (COSIS)................. 3-31 Section VII. Operations in CH Space.............................. 3-35 Section VIII. Security of Materials in Storage.................... 3-40 Section IX. Carrier Loading..................................... 3-43 Section X. Unit Loads.......................................... 3-85
CHAPTER 4. MHE AND PRINCIPLES.................................. 4-1
Section I. Basic Principles.................................... 4-1 Section II. Materials Handling Equipment........................ 4-4 Section III. Storage Aids........................................ 4-42 Section IV. Selection of MHE.................................... 4-59 Section V. MHE Requirement.Factor.............................. 4-63 Section VI. On-The-Job Training Course for Operators of MHE..... 4-76 i
TM 38-400/NAVSUP PUB 572/AFMAN 23-210 MCO 4450.14/DLAM 4145.42
Page
CHAPTER 5. STORAGE OF SPECIAL COMMODITIES. 5-1
Section I. Lumber............................................... 5-1 Section II. Ammunition and Explosives............................ 5-18 Section III. Vehicles (Tracked and Wheeled) and Artillery......... 5-18 Section IV. Subsistence.......................................... 5-39 Section V. Miscellaneous Commodities............................ 5-66 Section VI. Packaged Petroleum Products.......................... 5-91 Section VII. Metal Products....................................... 5-96 Section VIII. Cable Storing and Handling........................... 5-111
CHAPTER 6. SAFETY............................................... 6-1
CHAPTER 7. ON-THE-JOB TRAINING FOR STORAGE PERSONNEL............ 7-1
Section I. Training Plan........................................ 7-1 Section II. Training Program..................................... 7-1 Section III. Conference Leader.................................... 7-6 Section IV. Storage of Materials................................. 7-16 Section V. Principles of Materials Handling..................... 7-27
CHAPTER 8. STORAGE MANAGEMENT TECHNIQUES........................ 8-1
APPENDIXES
A. References........................................... A-1 B. Forms................................................ B-1 C. Metric/Temperature Conversion Charts................. C-1
GLOSSARY .................................................. G-1
ii
CHAPTER 1
GENERAL
1-1. Purpose and Applicability.
a. This manual establishes uniform storage and materials handling policies, procedures, and responsibilities for use by the Department of Defense (DOD) supply installations involved in the receipt, storage, issue and care of military supplies and equipment, except for preservation/ packing and defense reutilization and marketing facilities, maintenance of bulk petroleum fuel handling facilities, and hazardous materials storage. It is based on an installation which has a wide product mix and stores heavy tonnage items such as subsistance, clothing/textiles, packaged petroleum, oils, and lubricants (POL), as well as small items such as electronics and repair parts. Regardless of what is stored, the basic storage principles apply.
(1) Preservation/packing of military supplies and equipment is contained in joint services publications DLAM 4145.2/TM 38-230-
2/NAVSUP PUB 502/AFP 71-15/MC0 P4030.31C
(vol I), and DLAM 4145.2 (vol. II)/TM 38-230-2/NAVSUP PUB 503 (vol II)/AFP 71- 16/MCO P4030.21C. Guidance applicable to bulk petroleum fuel handling facilities is set forth in MIL-HDBK-201, Petroleum Operations. Hazardous materials storage is provided in TM 38-410/DLAM 4145.11/NAVSUP PUB 573/AFR 69-XX/MCO 4450.XX, Storage and Handling of Hazardous Materials.
(2) Defense Reutilization and Marketing Services manual 4160.5, Storage Operations (Warehousing), at the Defense Reutilization and Marketing Offices provides guidance on storage of excess and surplus materials.
b. The provisions of this manual apply to the Department of the Army (DA), the Department of the Navy, the Department of the Air Force, the Marine Corps (MC), and the Defense Logistics Agency (referred to collectively as "DOD Components").
1-2. Policy.
a. Implementation of this manual also requires compliance with DOD directives 4165.60, Solid Waste Management-Collection, Disposal, Resource Recovery, and Recycling Program, and 6050.1, Environmental Effects in the United States of DOD Actions.
Additionally, implementation outside the United States requires consideration of host nation environmental quality laws and regulations.
b. Storage and materials handling policies, procedures, and methods at DOD Component supply installations/activities will be uniform to the maximum practicable extent. Policies, procedures, and methods indicated herein by directive words such as "will," "shall," or "must," are mandatory. The use of such words as "may" or "should" indicates that the procedures and methods described are recommended, but not mandatory.
c. DOD 4145.19-R, Storage and Warehousing Facilities and Services, will be used in conjunction with this manual.
d. When necessary, DOD Components may au-thorize temporary deviations when compliance with mandatory provisions is temporarily impracticable or the deviation is required as an exigency measure.
Temporary deviations, including any extensions thereto, will not exceed 90 days.
DOD Components may authorize interim deviations from the mandatory provisions of the manual. Advice of any authorized deviation which may extend beyond 90 days will be forwarded to the Department of Army, ATTN: DALO-SMP, Washington, DC 20310, within 15 days of the date of authorization, for a coordinated determination as to whether it should be (a) incorporated into the regulation,
(b) continued as an authorized deviation,
(c) with-drawn, or (d) referred to the Assistant Secretary of Defense (Production and Logistics) (ASD (P&L)) for approval.
1-3. Organization and Use.
a. Organization. This manual is organized by major subjects (sections) and functions (parts). A table of contents reflects the scope of subjects included. The looseleaf format of the manual facilitates changes and additions to the text.
b. Table of contents and index. The organization of this publication makes it possible to locate desired information easily by referring to the table of contents in the front of the manual to determine general locations. Information that is too detailed for identification by this method may be located by reference to the topical index. c. Illustrations. The purpose of the illustrations is to show by means of photographs, charts, or completed sample forms, the principles and procedures explained in the text. The illustrations do not necessarily show current names, dates, and
1-1
TM 38-400/NAVSUP PUB 572/AFMAN 23-210 MCO 4450.14/DLAM 4145.12
figures, but are included in order that the principles outlined in the written instructions may be clarified.
d. Publication of changes. The AMC, Packaging, Storage, and Containerization Center (PSCC), DOD Working Group, which is chaired by a PSCC representative, will coordinate all changes and revisions to the manual with the appropriate service/
DLA storage and warehousing focal points.
Copies of proposed changes will be provided to the service/agency headquarters and an ASD (P&L) representative upon request.
1-4. Explanation of Terms.
xplanation of special terms used in this regulation are explained in the Glossary.
1-2
CHAPTER 2
STORAGE SPACE MANAGEMENT
Section I. Types of Storage Space
2-1. Introduction.
The contents of this section illustrate the general characteristics and functions of the most common types of storage space (covered and open) used by DOD Components.
2-2. Covered Storage Space.
a. Covered storage space is storage space within any roofed structure. It is used for the storage of a wide variety of material such as for the storage of general supplies and ammunition.
b. Covered storage space is generally comprised of two types of storage space, warehouse and nonwarehouse. Warehouse storage space includes general purpose, controlled humidity (CH), refrigerated, and flammable or hazardous materials facilities.
All other roofed structures are of the non-warehouse type. They include, but are not limited to, dry tanks, sheds, transitory shelters, nontraditional structures, and magazines.
(1) Warehouse storage facilities. These facilities have a roof, side and end walls, and many have ground-level and/or truck or railcar bed-level loading docks. Cantilever support canopies over docks may also be provided. They are generally single-story buildings, though multistory buildings qualify. These facilities can be modified to serve a variety of purposes such as converted to a controlled humidity facility.
(a) General purpose warehouse. This type of warehouse may be heated or unheated and is used for various storage functions and for the storage of a wide variety of items. The greatest portion of covered storage space at DOD installations is normally in this type of structure. The single-story structure with loading docks at truck and railcar bed level has become the standard warehouse. Figure 2-1 provides an example of a dock-level general purpose warehouse. An example of a ground-level general purpose warehouse is shown in figure 2-2.
1 As shown in figure 2-1, a truck dock of sufficient width on one side of the warehouse provides for loading/unloading of truck-hauled supplies. The matching dock and warehouse floor permit direct access of materials handling equipment (MHE) between warehouse interior and interior of carrier conveyance and vice versa.
2 Sometimes, on the side opposite the truck dock, a railcar dock runs the full length of the warehouse. This permits easy access to railcars from any warehouse door.
Rail docks should be located on either side of the two right angle sides of new warehouses to allow for future expansion of the buildings. Current construction techniques do not favor full length docks due to cost; therefore, a dock(s) to service a lesser number of doors becomes more practical.
3 Office space may vary in size and location. In most instances, such space is located within the warehouse. In others, the space is attached to the outside of the warehouse. In either case, the office space is generally located on the same side of the warehouse as the truck docks.
4 Two main aisles normally run the length of the warehouse to allow MHE or supplies to move straight through the length of the building. These main aisles are typically connected by cross aisles.
5 Functions normally found in a general purpose warehouse include loose issue and/or bulk storage, receiving, shipping, preservation, packing, carton fabrication, and unit and set assembly.
Special caged security areas may also be located in the warehouse for the storage of classified, pilferable, or sensitive items.
(b) CH warehouse. This type facility is used for the storage of items that require protection against damage and deterioration that can result from excessive humidity. It is particularly applicable for items that are to remain in storage for extended periods.
1 Almost any type of warehouse may be operated under CH conditions if properly sealed and equipped. The general purpose warehouse is, however, the type most frequently built for or converted into a CH environment (see fig 2-3).
2-2
2 See section VII, chapter 3, for details on operations in CH space.
(c) Refrigerated warehouse. The refrigerated warehouse resembles a general purpose warehouse although it is usually smaller, as can be seen in figure 2-4. Truck and railcar docks may be on opposite sides of the warehouse or combined on one side.
1 The interior of the warehouse is normally divided into two parts. One part is designated as chill space in which the temperature can be controlled between 32 degrees and 50 degrees (0 Celsius and 10 Celsius). The other part is designated as freeze space in which the temperature can be controlled below 32 degrees (0 Celsius).
2 When the warehouse is divided into chill and freeze space, there are no main aisles that run the length of the warehouse.
Cross aisles provide the access to railcar and truck docks.
2-3
(d) Flammable/hazardous materials warehouse. This facility is built of noncombustible materials and is compartmentalized with fire walls that have a 4-hour fire resistant rating. The hazardous materials facility contains explosion proof lighting, spill containment with sloped floors, and trenches which allow spilled material to collect in a sump tank.
Care must be taken to ensure that spills are contained and cannot enter into central sewerage or storm drain systems. Protection comes from an alarm reporting system and automatic deluge-type sprinklers connected to an adequate water supply. For further protection, the warehouse is usually located in an isolated area.
1 Inner fire walls without doors are preferred because of the greater fire protection afforded. However, fire walls without doors necessitate greater care in stock location since subsequent stock movements must be accomplished without benefit of free movement within the facility.
2 Figures 2-5 and 2-6 show an exterior view of a flammable warehouse and a hazardous materials facility, respectively.
A floor plan of a typical flammable/ hazardous materials facility is illustrated in figure 2-7. As indicated, storage areas are divided into acids, flammables, oxidizers, alkalis, and miscellaneous.
3 See TM 38-410 or individual service/ agency publications, as applicable, for details on operations in flammable/ hazardous materials areas.
2-4
(2) Nonwarehouse storage facilities.
These facilities have a roof but vary as to the number of walls and type of construction. Examples include--
(a) Shed. A shed is a structure without complete side and end walls. It may be equipped with utilities. A shed is used for the storage of materials that require maximum ventilation or materials that do not require complete protection from the weather. Figure 2-8 shows some typical exam-ples of sheds.
1 Most sheds are considered permanent structures since they are not readily dismantled for relocation. However, some sheds are transitory in that some are prefabricated structures which can be dismantled for movement and reassembly.
2 There are various means by which items that are stored in sheds and which require added protection from the weather may be protected while other items requiring only minimum protection are left semiexposed. For example, tarpaulins maybe used as side walls or pallets maybe positioned to form a protective wall. The use of pallets in this fashion, where feasible, serves a dual purpose since valuable storage space inside the shed will not be occupied by empty pallets.
2-8
(b) Magazine. This type of structure is designed for the storage of ammunition and explosives. These structures are widely separated in the storage area to minimize destructiveness should an explosion occur.
There are two types, above ground and earth covered.
1 Above-ground magazine.
(a) This magazine is similar in appearance to the general purpose warehouse;
however, it is built of fireproof materials and is well ventilated to lessen the danger of explosion (see fig 2-9). It normally has a dock that runs the entire length of the building to service both truck and railcars.
(b) Inside the typical magazine, main aisles do not run the length of the building as is common in a general purpose warehouse. Generally, cross aisles corresponding to the outside door locations run from the front to the rear of the building. However, in the instance of large-lot storage (e.g., a single item of ammunition, etc.), aisles in certain sections of the magazine may be eliminated.
(c) Although it may be necessary at times to use a general purpose warehouse to store small arms ammunition, the warehouse is not classified as a magazine because it does not have the special design construction required for proper storage of ammunition and explosives.
2 Earth-covered magazine.
(a) The structure, more commonly referred to as an igloo, is generally constructed of reinforced concrete with an arch-type roof covered with earth. The arched roof is an added safety feature since in the event of an explosion, the highest point of the arch which is also the weakest point would collapse first, thereby lessening the damage caused by the explosion. Figure 2-10 shows two common examples of igloos. Although igloos are not heated, the temperature inside ordinarily ranges between 40 degree and 45 degree in winter to between 60 degree and 70 degree in summer.
(b) The typical igloo has a single door on only one end which is smaller than a truck door; however, some have double doors.
Truck doors are rare. Normally, a centrally located dock(s) is constructed in the ammunition area to service trucks and railcars.
2-9
(c) The isolated location and peculiar construction of the igloo limit the type of MHE that can be used. A clearance must be provided between stacks and walls.
This clearance will be in accordance with commodity characteristics and regulations of the appropriate military service. In addition to quantity distance factors, uniform stacking heights are limited due to the arched roof.
(c) Other. There are various other non-warehouse facilities that can be used for storage such as the hangar shown in figure 2-11 which is used for the storage of helicopters. In addition, the following are included:
1. Dry tank. Figure 2-12 shows a dry tank storage area. The tank is constructed of bolted metal except for a concrete floor.
It may be temperature and/or humidity controlled. The tank may be completely sealed (sections must be unbolted for access) or fitted with a single door. Dry tanks are used for long-term storage. Access roads parallel the rows of tanks. Because of the size and shape of dry tanks, there are no operating aisles for MHE although MHE is used in the storing process.
2-11
2. Transitory shelter. A transitory shelter is a prefabricated metal structure normally with complete sides and ends.
Utilities are not normally included therein although they are sometimes provided. Such structures can be dismantled for movement and reassembly. A transitory shelter is classified as a storage aid rather than a real property facility. Figure 2-13 shows an example of a transitory shelter.
2-12
3. Nontraditional storage structures.
These structures generally offer a less costly alternative to the conventional brick-and-mortar type storage facilities.
Most offer the advantage of a clear span, on-site fabrication, and fast on-site assembly. Some offer the advantage of being totally relocatable. They can be constructed of metal as can be seen in figure 2-14. This structure is referred to as a RELMS (rapidly erectable light-weight mobilization structure). Other structures are constructed of fabric stretched over a metal frame and are referred to as stress tension shelters (STS) (see fig 2-15).
2-13
2-3. Open Storage Space.
a. Open storage space is all uncovered space that is used for storage purposes.
There are two types of open storage areas, improved and unimproved.
(1) Open improved storage space. This spaceincludes areas that have a finished surface such as space that has been graded and surfaced with concrete, tar, asphalt, crushed stone, gravel, or other suitable topping. The area is surfaced with a suitable topping which provides adequate drainage necessary to afford the item with protection from wet ground conditions.
Figure 2-16 shows an example of a hard surface open improved storage area.
(a) An open improved storage area usually has a hard surface of a more conventional surfac ing topping which provides an adequate running surface for the operation of MHE. A steel mat topping may be used in some instances due to immediate need or lack of other suitable topping; however, this method is not desirable.
(b) Storage layouts for open improved areas vary because of terrain features and types of commodity stored. In reality, aisles become roadways due to the size of the MHE required.
(2) Open unimproved storage space.
This space consists of unsurfaced open areas designated for storage purposes.
(a) The limitation on the use of MHE is a significant disadvantage of open unimproved storage. This type storage should be used only with certain stock and only when a higher upgrade of open improved space is not available.
(b) A storage layout for an open unimproved area is affected by the same criteria as that for open improved storage areas. However, to take advantage of existing drainage, supplies may have to be positioned and aisles or roadways may have to be located, without regard to conventional storage practices.
b. Storage managers must be aware that material stored in open storage areas may be either approved or unapproved for storage in such areas. Material that is approved for open storage is so authorized because there is little or no concern of damage to the material which could result from the elements of an open environment. Sometimes material stored in open areas is unapproved for storage in that the material requires covered storage but is being stored in open areas. Unapproved open storage can result in causing severe damage to the material being stored because of overexposure to harsh environmental conditions.
Section II. Space Requirement Factors
2-4. General.
a. Storage space is a basic resource of any storage operation. Economy depends upon the optimum utilization of this space and the proper arrangement of operations incident to the receipt, storage, and issue of materials. Space economy can be obtained only by thorough planning for the use of space.
b Space requirements are not computed on an "after the fact" basis. That is, inventories are not
2-15 stored and then computations developed to indicate that X amount of storage space is required. To the contrary, space requirements are projected ahead of actual physical occupancy with sufficient accuracy to avoid overallocation.
2-5. Scope.
This procedure does not apply to wet storage areas; rolling stock yards; petroleum, oil, and lubricants (POL) tank farms; storage of complete aircraft; industrial tool storage in contractor plants; or to ammunition storage space computations which are developed under separate instructions of the military services.
2-6. Considerations in Space Requirement
Computations.
There are many factors which must be considered in developing a procedure for computing storage space requirements. These factors must be recognized in a way that will enable ready adaptability by all echelons concerned with computing space requirements or occupancy factors. The following identify these key factors, some of which are illustrated in figures 2-17 through 2-19:
a. Quantity of inventory. Although many elements contribute to the computation of storage space requirements, quantity is the basic element or conversion factor. From this, space requirements can be computed through application of dollar value and/or cubic footage of supplies.
b. Characteristics of storage facility.
Storage space is three dimensional;
therefore, facility characteristics must be carefully analyzed. Limitations such as stacking height, floor capacity, structural clearance, and other obstacles must be recognized. For example, coils of steel banding are usually stacked in a column that is erected to only moderate storage height.
Although the characteristics of this item with regard to stability would allow a substantially higher stacking level, the weight, considering floor load capacity, has reached the maximum. Therefore, floor load capacity may influence stacking heights.
c. Equipment capabilities. Use of potential warehouse storage height may be restricted by equipment capabilities to achieve the vertical utilization. For example, even though a warehouse provides floor load capacity and clear vertical space, full utilization could not be realized if adequate stacking equipment were not available.
d. Commodity characteristics. The maximum stacking height potential is also influenced by the characteristics of the material or its packaging.
These may not permit stacking to the height available. The type of commodity being stored must, therefore, be considered in determining whether the gross cube available can be filled. This consideration supports the idea of categorizing supplies into groups to promote a constant storing height potential. Some examples of the effects of commodity characteristics on storage heights (see fig 2-20) include-
(1) Forklift trucks are representative of unpacked and unusually shaped items that preclude stacking. Items of this type, in the interest of efficient space utilization, are normally located in storage areas where the least storage height exists. Inventory such as this is categorized as being of limited stacking height potential.
(2) Items which are packed in containers of substantial strength or items which support the surface of the containers will ordinarily lend to
2-18 high stacking. Therefore, selection of storage location should provide for maximum stacking height potential.
(3) There are many items which lend only to moderate stacking heights for several reasons. Packs may be too weak to withstand the weight imposed as a result of relatively high stacking or the packs may be unstable.
Bagged items are an example of items that can be stacked to a limited height.
e. Total warehouse storage space. The gross storage space within a warehouse includes-
(1) Storage support space. See paragraph 2-13e.
(2) Aisles. See paragraphs 2-9f and 2- 13e.
(3) Structural loss. See paragraph 2-13e.
(4) Net storage space. See paragraph 2- 13e.
f Occupancy of net storage space.
Considerations such as ceiling heights, commodity characteristics, and "elbow room" are factors which preclude the possibility of complete occupancy of net storage space.
In any storage operations, it is desirable to have "elbow room" available for operations flexibility. This "elbow room" space must be limited to the absolute minimum for effective storage. Sufficient "elbow room" should be available to minimize the continuous necessity for relocation of stocks to "fit" additional receipts into the storage pattern. Fifteen percent of the net available space is considered an adequate allowance for "elbow room" for general supplies. Ammunition is governed by quantity-distance factors found in appro-priate publications.
2-7. Development of Data for Use in Space Requirement Computations.
Computation of space requirements should use cubic feet and/or square feet as conversion factor(s) in relating material to space. In the planning for, and selection of material for storage in specific warehouses or warehouse sections, the selection should be based upon the volume of inventory, stackability, bin requirements, etc. In other words, material with low stackability should not be located in high ceiling warehouses when lower ceiling or lower floor load capacity warehouses are available. This also applies to bin areas, storage support areas, relatively small inventories of the same item, etc. The following will apply in developing data to support space computations:
a. Average stacking heights. The characteristics of storage facilities influence the heights to which material may be stacked. The composition of the inventory will normally vary from installation to installation with resultant effects on average stacking heights. For example, a substantial inventory of an item that possesses very limited high storage potential, as opposed to a very limited inventory of the same item, would have a marked bearing on storage height average for that item. For this reason, each storage activity must compute independent data which will reflect average potential storage height of inventory.
(1) In order to relate to space, the stacking height must be established.
Establishing stacking height should not be predicated on the basis of the height to which supplies are currently stored, but rather to the potential storage height, that is, the height to which supplies are capable of being stored in accordance with proper warehousing practices. Inventory is another influence which must be recognized. For example, the quantity on hand could result in some supplies being stacked to less than the potential height. This practice reduces the average potential height. The term "ad-justed potential storage height" applies to this recomputation.
(2) It will be necessary to survey inventories in order to determine acceptable and attainable storage heights. To provide greater accuracy and lessen expenditure of manpower, computers should be used, when available. To attain satisfactory benefits from such a survey and to avoid establish-ing stacking heights for each item, supply inventory should be grouped into selected categories and the average heights determined for each category. For example, separate categories may possibly be established for type 1, easy load; type 2, average load; and type 3, difficult load, as defined in the glossary of terms, and for unpacked items such as vehicles.
(a) Supply groupings should be sufficiently categorized to reflect relatively constant and accurate average potential stacking heights as well as adjusted potential stacking heights which take into account the variables of supply inventory.
(b) Results of the survey will indicate an overall potential height and adjusted potential height for each category grouping. This should be frequently assessed to assure data correctly reflect the current storage situation.
b. Square foot computations.
(1) Stacking height data will be reconciled to the amount of floor area (square footage) that is currently utilized in storing inventory. In the event that potential or adjusted potential storage height is not fully occupied, provisions must be made to identify the current excessive occupancy of square feet of floor area in order to reflect the actual net square feet of storage space required to
2-19 store inventory. The height of stacking should be extended by attrition to bring the actual storage in balance with the adjusted potential, thereby equalizing the amount of net square feet actually occupied.
(a) Before the square feet required to store inventory can be obtained, the space occupancy effectiveness (see Fig 2-21) must be calculated, as follows:
A Potential vertical Space utilization
--- = EFFECTIVENESS
P and A --- = Adjusted vertical Space utilization
AP EFFECTIVENESS
where:
P = POTENTIAL Storage height, A = ACTUAL Storage height, and AP = ADJUSTED POTENTIAL storage height.
(2) As an example, a survey has indicated that supply category X is capable of being stacked to an average potential height of 14 feet and an average adjusted potential height of 13 feet. The survey also disclosed that material currently occupies 218,000 square feet of floor space. The average stacking height to which materials are actually stored averages only 12 feet. How many square feet are required to store the inventory?
(a) First, the space occupancy effectiveness is calculated as follows:
A 12 _ 86% potential vertical space
- utilization effectiveness p 14 and A 12 _ 92% adjusted potential vertical
- - space utilization effectiveness.
Ap 13
(b) Then, the square feet required to store the inventory can be calculated as foflows:
187,480 square S x E = 218,000 x .86 = feet required for optimum effectiveness and
200,560 square feet required to S x E = 218,000 x .92 = store present inventory.
c. Cube Foot computation. Since both hori-zontal and vertical dimensions have been provided in paragraphs (a) and (b) above, the multiplication of the total square foot area of storage by the stacking height (feet) will equal the cubic feet of storage space available. The following is applicable:
2-21
Also, CF CF = CUBIC FEET required to store ---- S additional inventory, H H = Vertical storage HEIGHT to which additional inventory may be where: stacked, and S = SQUARE FEET required to store additional inventory.
(3) Allowance for outgoing shipments (esti-mated). This is a reversal of the procedure for in-coming receipts and is computed as follows:
0 H = Vertical storage HEIGHT to which ---- = CR inventory was stacked, VC
CR = CUBIC FEET of space where: RELEASED through shipment O = OUTBOUND shipment cost value, of inventory, and VC = DOLLAR VALUE of "on hand" inventory per CUBIC foot, and SR = SQUARE FEET of space CR = CUBIC FEET of space RELEASED through shipment RELEASED through shipment of inventory.
of inventory.
e. Bin areas. The computation of space re- Also, quired for establishment of bin areas will be predicated on the following:
CR (1) The number of line items to be stored ----- = SR which will reflect the number of bin openings re- H quired.
(2) The size of bin openings (outside dimen-where: sions.
(3) The height to which bin columns will be erected.
f. Space utilization in storage support. Not all space in a storage area can be allocated to mate-rail storage. However, the allocation of space from actual storage to storage support functions should
2-23 be held to the minimum consistent with good oper-ating practices. Considerations in computation of space requirements for storage support activities (see fig 2-26) are as follows:
(1) The requirements for space for storage support functions are greatly influenced by the mission responsibilities of the particular activity. For example, tonnage handled or net storage space operated need not necessarily have an absolute bearing on the amount of space allocated to preservation and packing.
Detailed evaluation of the particular operating circumstances would, therefore, be necessary before accurate computation could be accomplished.
(2) It would be impractical to establish firm ratios of space allotted for storage purposes on the basis of personnel employed or gross area operated. However, storage management personnel should frequently appraise actual support requirements to assure that valuable space is not allocated to these functions in excess of minimum requirements.
(3) Computation of space requirements for support functions should be developed, in great part, through review of both past and current requirement experience. When projecting future needs, consideration should be given to possible mission changes which would alter requirements. Such acknowledgement will enhance the accuracy of projected allocations as compared to actual proved need. g. Gross space requirements.
(1) The formula for computing gross space requirements is
N + A + SS + S = G
where:
N = NET SQUARE FEET of space allocated to storage, A = Space allocated to AISLES, SS = Space consigned to STORAGE SUPPORT functions, S = STRUCTURAL loss space, and G = GROSS storage area.
(2) This formula applies to determining gross storage space requirements in covered and open
2-24 storage areas. In applying the formula to open storage areas, consideration need not be given to such facility restrictions as may affect stacking heights.
Section III. Determination of Storage Space Requirements (DOSSR) Method his section will be published at a later date.
Section IV. Planning the Storage Layout
2-8. Introduction.
a. A storage area floor plan layout is an excellent management tool for space control.
It enables planning for the effective use of space. The layout is the framework in which the overall depot storage space is developed. It serves as the basis for developing the storage area planographs. The layout is also the basis for preparation of the storage space status report (see para 2- 12f). Storage plans for installations and activities storing ammunition will be developed as prescribed by the responsible military service.
b. Using the principles of space requirements determinations outlined in section II, this chapter, and the DOSSR study method discussed in section III, this chapter, effective storage layouts can be developed.
c. A complete and current floor plan shows the actual manner in which the gross space within a storage area is used. The plan shows the division of space into storage, receiving, shipping areas, main and cross aisles, fire aisles, and offices. Each section or other subdivision of the floor plan will show the square footage of gross space, the nonstorage space, and the net space available for storage.
2-9. Factors Influencing Layout Plan.
a. Item similarity. Items with similar handling requirements should be stored together when practicable. This facilitates storage and issue and also contributes to effective care of supplies. There is normally no requirement that material will be segregated and stored by an inventory manager.
b. Item popularity. Activity or popularity is an important factor in planning the storage layout for material.
The fastest moving bulk stocks should be planned for storage in areas that are quickly and easily accessible to reduce travel of MHE and stock selection personnel.
Loose issue areas should be located adjacent to packing and processing areas. Fast moving bin stocks should be easily ac-cessible to expedite stock selection and replenishment actions. To the extent feasible, items with the slowest turnover rate should be planned for placement in areas progressively farther from active stock or processing areas. The principle of location by popularity is shown in figure 2- 27.
c. Item size and weight. The dimensions and weight of individual items affect not only the amount of storage space allotted, but also the location in which items are to be stored. For example, a 5-ton dynamo would be stored in a location that would provide a balance between accessibility to required MHE and the least amount of intradepot transport. Normally, except for those items requiring overhead cranes for handling, the greater the item density the less overhead clearance or ceiling height required.
2-25
d. Item quantity. Quantity of material on hand affects the amount of space required on the layout. Frequently, it is desirable to increase the amount of space assigned to an item in a single location in order to eliminate the need for two locations. This may reduce effort and travel in replenishment actions for binnable items and reduce administrative effort required for maintenance of the location record system.
e. Item characteristics. The characteristics of most items of supply are such that special storage areas are not required. However, some items require special considerations. They include hazardous, sensitive, and perishable and deteriorative items.
(1) Hazardous. These materials have characteristics which require that they be specially stored or handled to prevent a hazard to personnel and facilities. This factor must be kept in mind when planning storage layouts (see TM 38-410) or service/ agency publication, as applicable.
(2) Sensitive. Sensitive materials require a high degree of protection and control due to statutory requirements or regulations. Included in this category are items such as narcotics and drug abuse items; precious metals; high-value items;
highly-technical items; items of a hazardous nature; and small arms, ammunition, explosives, and demolition material (see sec VIII, chap 3).
(3) Perishable and deteriorative. Some materials have a limited storage life and care must be taken to ensure that the oldest stock or that which may have an earlier expiration date is issued first. Many foods, drugs, etc., must be kept in refrigerated areas or in temperature-controlled areas.
For all items of a perishable or deteriorative nature, the most suitable storage environment must be made available (see sec IV, chap 5).
f. Aisles. Preplanning of aisle positioning on layouts must be done prior to placement of materials. Allowing the aisle layout to take shape as materials are placed in stock may result in placing materials in inaccessible locations and/or in loss of space.
(1) Aisle layout is determined by the structure of the warehouse; quantity, nature, and activity of materials to be stored; and by the types and capacity of available MHE.
(2) Aisles should only be wide enough to provide maneuvering room for MHE available for the stock storage and selection actions. For aisle widths required for forklift truck operation, see paragraph 1 below.
(3) Width of aisles in bin and shelving areas should permit easy movement of stock selector trucks through the storage area.
Generally, this requires an aisle of 30 to 36 inches in width.
(4) Aisles should be planned to provide straight and clear passageways unobstructed by support columns, elevators, heaters, or other such construction features. A particularly important factor is the location of columns. Space loss due to columns will be reduced if columns are used as aisle and bay boundaries.
(5) There are three major types of aisles:
working, personnel, and service.
2-26
(a) Working Aisles. Working aisles are passageways used to access storage locations during the receipt, inspection, and issue processes. Working aisles are of two types, transportation aisles which run the length of the building and cross aisles which run across the width of the building.
1 The working aisle widths specified herein are not to be construed as the absolute limitation for all operations. They represent the dimensions under which most operations may be conducted. Aisle widths must be established to ensure complete consonance between operational efficiency and space economy. The aisle widths specified below are based upon a load of 40 inches on electric vehicles.
Sit-down counterbalanced rider 12 feet 0 inches (4 wheel) truck.
Stand up counterbalanced (3 10 feet 0 inches wheel) truck.
Reach truck.....................8 feet 0 inches Deep reach truck................8 feet 6 inches Swing reach truck...............5 feet 6 inches to 6 feet 0 inches Turret truck....................5 feet 6 inches to 6 feet 0 inches isles widths for different load lengths will be determined on the basis that a variation of 8 inches in the load length will have a corresponding variation of 6 inches in the aisle width. For example, a 48-inch load length will increase the aisle widths indicated above by 6 inches. Determination of aisle width is affected by turning radius of MHE to be used.
2 In most storage layouts, the volume of activity requires two transportation aisles of efficient layout. Such aisles run the length of the building and should be wide enough to permit two-way traffic of MHE being utilized in that particular area.
3 At least two cross aisles are needed in the standard warehouse section.
Such cross aisles should be in accordance with the aisle requirements outlined in paragraph 1 above. The bulk of storage operations will be carried on in cross aisles.
(b) Personnel aisles. Pesonnel aisles are those used as pedestrian routes only and may be required for access to door or to special interior areas. Such aisles should be held to a minimum. If traffic volume does not create a safety hazard to personnel, working aisles can/should double as personnel aisles.
(c) Service aisles. Service aisles are those which provide access to stacks for inventory, inspection, or for protective processing. The requirements for service aisles are very limited. Efficient warehousing operations require that each storage row contain only one item with the same number of containers per pallet. This facilitates inventory as well as issue and normally makes special aisles unnecessary.
However, such aisles may be necessary for special commodities (e.g., subsistence, etc.) which require frequent inspections.
(6) Every block of material should be adjacent to a working aisle and stored so that stock can be removed without the necessity of moving another item. The simplest means of providing accessibility is to create a large number of aisles and short rows, but this practice is inconsistent with the principle of minimizing the number of aisles. The best rule to follow is to be certain that materials are stored on both sides of and facing the working aisles. Pallet racks, placed parallel to the long dimension of the building, in side-to-back storage with a bulk stock, permit the use of transportation aisles to provide accessibility to small lot material.
(7) Since a mix of material may contain a wide variety of lot sizes, various bay depths must be provided. For example, if a single column of pallet loads is placed in a bay which has a capacity of five such columns, space for four columns is lost. The availability of a variety of bay sizes is affected by aisle layout and the direction of storage. When the best conceived plan for direction of storage fails to produce a sufficient number of small bays for the class of material handled, the number of working aisles must be increased.
g. Working areas. Working areas are nonstorage space (other than aisles) in which operations incident to storage or materials handing are performed. Working areas include receiving and shipping bays, packing floor space, strapping lines, battery charging stations, offices, and locker rooms. Such spaces reduce storage areas and, therefore, should be held to the minimum
(1) Working areas are normally located in those portions of a warehouse which have the lowest ceilings. Usually, areas which serve all personnel in a building (e.g., offices, locker rooms, etc.) are located in the center section of the building against a side wall. This precludes entering personnel from walking through the storage areas and interrupting work. Working areas are located so as to minimize to total time required for travel of personnel and equipment between storage locations and working areas.
2-27
(2) Although set rules cannot be established for allocation of space to working areas, it is essential to keep such space to a minimum. Working areas must be controlled to ensure that such areas do not expand beyond the defined boundaries.
(a) Temporary storage of materials within a working area, particularly in receiving and shipping bays, should be held to a minimum Receipt and processing operations should he organized so that materials can be processed immediately and removed to their storage locations.
(b) Utilization of cube in working areas is just as important as in storage space. The use of pallet racks and shelving frequently will save space in working areas.
(c) When practical, working areas should be consolidated. For example, creating a centralized packing operations for several buildings will result in less space consumption than a separate operation in each of the buildings. Also, this facilitates the centralized use of special equipment and concentrates the supervision of specialized jobs.
2-10. Preparation of Layout Plan.
When making storage layouts, whether for covered or open storage, a floor plan for each storage area should be prepared. The plan must indicate all obstacles such as support columns, stairwells, elevator shafts, office locker rooms, and rest rooms (see fig 2-28).
a. Basic bulk storage layout criteria.
Most of the principles involved in bulk storage are exemplified in the layout for a complete building as illustrated by figures 2-29 and 2-30. Various layouts for bulk storage are shown. There is practically no variation in bay depth as shown in figure 2- 29; each bay is about 40 feet in depth, thus, a lot of less-than-carload quantity will not completely fill a bay and, therefore, results in loss of space. The main aisle runs lengthwise through the building.