U.S. General Services Administration 400 15th St SW Auburn, WA 98001 GSA Northwest/Arctic Region

SOW Lynden Mold Remediation and Fall Protection

LAND PORT OF ENTRY, LYNDEN, WASHINGTON

MOD

MOLD REMEDIATION

STATEMENT OF WORK, 03/26/2016

DESCRIPTION: Abate mold and repair room ceiling drywall. Replace existing double doors. Level and seal floor. Replace existing screen window. Install new heater with controls.

LOCATION: Land Port of Entry (LPOE) 9949 Guide Meridian Rd, Lynden WA 98264

BACKGROUND – a 240 SF room has water damage which has created an unsafe condition due to the presence of mold. Project is to replace water damaged drywall and remove all mold from horizontal and vertical surfaces. Room contents are to be removed, cleaned and stored during the course of work. Existing double doors and window are rusted and require replacement. Floor requires epoxy coating. New lighting and heater is required.

1. STATEMENT OF WORK

1.1 SCOPE

Provide labor, material, and equipment necessary to remediate the existence of mold and return room to safe condition.

1.1.1. Remove, clean and store all room contents. Some items may be deemed unsalvageable by the Government and shall be disposed.

1.1.2. Disconnect incinerator and recycle – provide Government receipt of recycle

1.1.3. Remove all evidence of mold.

1.1.3.1. Isolate the entry door with plastic sheeting

1.1.3.2. Place plastic sheeting on the floor out to about 4 ft, in order to enhance cleaning of the area after the sheetrock removal.

1.1.3.3. Prior to cutting out the sheetrock, wet the molded areas with a water spray (lightly).

1.1.3.4. Cut the sheetrock and place into garbage bags

1.1.3.5. After sheetrock removal inspect the framing and determine if additional cleaning is required (if this is wood framing then the framing may need to be wet sanded). Remove the plastic sheeting and dispose of it within the garbage bags.

1.1.3.6. Should only use a HEPA vacuum in cleaning the area or damp wipe (small debris) in order to removal all debris

1.1.4. Demo existing ceiling drywall and clean all vertical/horizontal surfaces to remove any presence of mold per steps 1.1.3.1 – 1.1.3.6. No earlier than one hour after cleaning air samples shall be collected and analyzed to ensure mold has been removed and area is safe for normal construction activities. All mold affected materials shall be disposed according to state regulations.

1.1.5. Remove portion of incinerator stack so it is no longer protruded through the ceiling.

1.1.6. Replace drywall to a smooth surface and paint white.

1.1.7. Install 208V ceiling or wall mounted heater and thermostat control.

1.1.8. Replace existing double doors with new. New doors shall not have vents. Re-use existing lock core. Paint to match.

1.1.9. Level and epoxy seal existing concrete floor.

1.1.10. Replace screen window with double pane type.

1.1.11. Install two LED light fixtures equivalent to 4’ fluorescent type.

LAND PORT OF ENTRY, LYNDEN AND SUMAS WASHINGTON

MOD

INSTALL METAL FIXED ROOF FALL PROTECTION ANCHOR

STATEMENT OF WORK

DESCRIPTION – Install metal fixed fall protection anchors on membrane and standing seam roofs.

LOCATION: Kenneth G. Ward Border Station, 9949 Guide Meridian Road Lynden WA, 98264.

Sumas L.P.O.E., Cherry and Boundary, Sumas, WA. 98295-9900

BACKGROUND – Currently both Sumas and Lynden Land Ports of Entry do not have fall protection anchors. This is a safety concern for both these buildings and this project as well as future projects and maintenance work to be completed.

STATEMENT OF WORK

1) INSTALL METAL FIXED ROOF FALL PROTECTION ANCHOR

a) METAL FIXED ROOF FALL PROTECTION ANCHOR

Compatible with 24 gauge metal corrugated roofs or thicker Standard product fastens through the membrane, insulation and into the metal sheathing.

Zinc plated base plate with waterproof seal for membrane type roofs.

Quick and easy installation The anchor posts are designed to tip over and the activation absorbs the energy of the fall arrest to minimize the stress on the building Meets or exceeds all applicable industry standards with OSHA and ANSI Z359.1

b) MEMBRANE ROOF FALL PROTECTION ANCHOR Compatible with membrane roof structures Standard product fastens through the membrane, insulation and into the metal sheathing.

Zinc plated base plate with waterproof seal for membrane type roofs.

Quick and easy installation The anchor posts are designed to tip over and the activation absorbs the energy of the fall arrest to minimize the stress on the building.

OSHA compatible anchor ring at top of post for added safety.

Meets or exceeds all applicable industry standards with OSHA and ANSI Z359.1