Hilo FB elevators 2011.pdf
PDF 14 KB Posted
- Attached to
- Operation, Maintenance and Vertical Transportation Equipment Services Federal contract opportunity
- Solicitation number
- GS-09P-12-KS-D-0006
About this file
Hilo FB VTE Equipment List
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Updated Q A.pdf | ||
| Amendment 05.pdf | ||
| Section L.2 Page 130.pdf | ||
| SF 1449 | — | |
| Questions and Answers.pdf | ||
| Section C.5 Page 20.pdf | ||
| Amendment 04.pdf | ||
| Hilo Jobwalk Sign-in Sheet.pdf | ||
| Honolulu Walkthrough Sign-In Sheet.pdf | ||
| Amendment 03.pdf | ||
| J.List Of Attachments | — | |
| PJKK elevators 2011.pdf | ||
| L.2 Additional Instructions | — | |
| Solicitation Cover Page | — | |
| Additional Equipment List.pdf | ||
| J.List Of Attachments | — | |
| Amendment 02.pdf | ||
| Hilo FB Equipment List.pdf | ||
| Hilo Customs Equipment List.pdf | ||
| PJKK Equipment List.pdf | ||
| J. List Of Attachments.pdf | ||
| Amendment 01.pdf | ||
| Solicitation Cover Page.pdf | ||
| Hawaii O M Solicitation Part 1.pdf | ||
| Hawaii O M Solicitation Part 2.pdf |
Show all 25
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Number & Location Type/No.of VTE Type of machine Manufacturer Stops Speed (fpm) Capacity (lbs.)
Routine Periodic 5 year load test
HI0001ZZ
U.S. Post Office & FB #1 passenger geared traction Otis 2 100 1800 N/A N/A OUT-OF-SERVICE
154 Waianuenue Avenue #2 West passenger holeless hydraulic Cemco 4 100 2000 Jan July N/A
Hilo, HI #3 East passenger holeless hydraulic Cemco 4 100 2000 Jan July N/A
#4 Makai side inclined platform lift Garaventa 4 steps 12 550 Jan July N/A
#5 Mauka side inclined platform lift Garaventa 4 steps 12 550 Jan July N/A
NOTES:
Elevators #2 & 3 have MCE controls - 1994
JANUARY 2007 NOTE: ELEVATOR #1 WILL BE OUT-OF-SERVICE UNTIL FURTHER NOTICE.
ASME A17.1 & A18.1
Routine Tests & Inspections are performed every 6 months
Periodic Tests & Inspections are performed annually
ASME A17.1 Inspections Due
U.S. GENERAL SERVICES ADMINISTRATION - HAWAII OFFICE
ELEVATOR EQUIPMENT DATA