GS-04-P-16-EX-C-7030_Combined_Synopsis_Solicitation_02_26_2016_16-50-58_PDF.pdf
PDF 4 KB Posted
- Attached to
- Replace and Improve Roof Cover and Rainwater Drainage Systems, U. S. Courthouse, Asheville, NC
- Solicitation number
- GS-04-P-16-EX-C-7030
About this file
Not Listed
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Solicitation Number: GS-04-P-16-EX-C-7030 Notice Type: Combined Synopsis Solicitation Notice Title: Replace and Improve Roof Cover and Rainwater Drainage Systems - GS-04P-15-EX-C-0186 Notice Description: Solicitation Number GS-04P-15-EX-C-0186 This project involves the design, repair, replacement and improvement of the roof cover systems and rainwater drainage systems at the Historic U.S. Courthouse, 100 Otis Street, Asheville, NC 28801. The existing low-slope roof cover involves twelve separate roof areas totaling approximately 13,000 square feet. The low-slope roof cover consists of ballasted single-ply EPDM membrane over light weight insulating (cinder) concrete and structural concrete decks. However, the sally port roof involves rigid board insulation and metal decking, in addition to the EPDM membrane. The steep slope roof cover involves approximately 15,000 square feet of standing seam metal roof membranes over the attic and approximately 1,500 square feet of contiguous gutters. Both roof cover systems include EPDM base flashing; metal counterflashing; concrete parapet copings; internal rain leaders and conductors; and associated sealants. The Designer- Builder shall design and construct appropriate repairs, replacements and improvements of these roof cover and rainwater drainage systems. New low-slope roof membranes are limited to multi-layer atactic polyproylene (APP) or styrene butadiene styrene (SBS) modified bitumen roofing systems with highly reflective surfaces. New gutter membranes are limited to fluid-applied aliphatic polyurethane and polymethylmethacrylate (PMMA) waterproofing. Section 4 of this statement of work provides additional requirements for these new systems and components. The Designer-Builder shall also provide a web-camera surveillance system to monitor on-site work progress through project completion.
Posting Location: FedBizOpps FBO Classification Code: Z -- Maintenance, repair, and alteration of real property NAICS Code: 238160 -- Roofing Contractors SB/SA Type: No Set Aside Used Response Date: 3/8/2016 Archive Date: 4/7/2016 Place of Performance:
100 Otis Street Asheville, NC 28801 United States
Government URL:
Government URL Description:
Government Email Address: william.peterson@gsa.gov Contact Name: William Peterson Attachments:
File details come from the government source that posted it. Updated .