AIR FORCE UTILITIES PRIVATIZATION - REQUEST FOR PROPOSAL (RFP) ATTACHMENT JA2
(Attachment JA2 Natural Gas Distribution System Template – SEPTEMBER 2009_REV MAY 2010) User Edited: v07 07Feb11
JA2-1
ATTACHMENT JA2
Barksdale AFB Natural Gas Distribution System
Table of Contents
JA2 BARKSDALE AFB NATURAL GAS DISTRIBUTION SYSTEM ............................... JA-2
JA2.1 BARKSDALE AFB OVERVIEW ............................................................................................ JA-2 JA2.2 NATURAL GAS DISTRIBUTION SYSTEM DESCRIPTION .................................................... JA-2
JA2.2.1 Natural Gas Distribution System Fixed Equipment Inventory .................................. JA-3 JA2.2.2 Natural Gas Distribution System Non-Fixed Equipment and Specialized Tools ....... JA-5 JA2.2.3 Natural Gas Distribution System Manuals, Drawings, and Records ......................... JA-6
JA2.3 SPECIFIC SERVICE REQUIREMENTS ................................................................................... JA-6 JA2.4 CURRENT SERVICE ARRANGEMENT ................................................................................. JA-7 JA2.5 METERING .......................................................................................................................... JA-7
JA2.5.1 Existing Meters ............................................................................................................ JA-7 JA2.5.2 Required New Meters ................................................................................................... JA-7
JA2.6 MONTHLY SUBMITTALS .................................................................................................... JA-7 JA2.7 ENERGY-SAVINGS PROJECTS ............................................................................................. JA-8 JA2.8 SERVICE AREA .................................................................................................................... JA-8 JA2.9 OFF-INSTALLATION SITES ................................................................................................. JA-8 JA2.10 SPECIFIC TRANSITION REQUIREMENTS .......................................................................... JA-8 JA2.11 INITIAL SYSTEM DEFICIENCY CORRECTIONS (ISDC) .................................................... JA-8 JA2.12 RIGHT OF ACCESS TO THE UTILITY SYSTEM ................................................................... JA-9
JA2.12.1 Map of the Utility System .......................................................................................... JA-9 JA2.12.2 Lateral Extent of the Right-of-Access, and Points of Demarcation ........................... JA-9 JA2.12.3 Environmental Baseline Survey ............................................................................... JA-14
LIST OF TABLES
TABLE 1 - FIXED INVENTORY ........................................................................................................... JA-4 TABLE 2 - SPARE PARTS ................................................................................................................... JA-6
TABLE 3 - SPECIALIZED VEHICLES AND TOOLS .............................................................................. JA-6 TABLE 4 - MANUALS, DRAWINGS, AND RECORDS ........................................................................ JA-6 TABLE 5 - EXISTING METERS............................................................................................................ JA-7
TABLE 6 - REQUIRED NEW METERS ................................................................................................ JA-7 TABLE 7 - ENERGY-SAVINGS PROJECTS .......................................................................................... JA-8 TABLE 8 - SERVICE CONNECTIONS AND DISCONNECTIONS ......................................................... JA-8 TABLE 9 - INITIAL SYSTEM DEFICIENCY CORRECTIONS ................................................................ JA-9
TABLE 10 - STANDARD POINTS OF DEMARCATION ..................................................................... JA-10 TABLE 11 - UNIQUE POINTS OF DEMARCATION .......................................................................... JA-11
(Attachment JA2 Natural Gas Distribution System Template – SEPTEMBER 2009_REV MAY 2010) User Edited: v07 07Feb11
JA2-2
JA2 Barksdale AFB Natural Gas Distribution System
JA2.1 Barksdale AFB Overview
Barksdale Air Force Base is located in the northwest portion of Louisiana, within the Shreveport-Bossier City Metropolitan Statistical Area (MSA). Accessible by I-20 (east-west) and I-49 (north-south), Barksdale AFB is approximately 180 miles east of Dallas and 312 miles northwest of New Orleans. Occupying nearly 22,000 acres of land, the Base is bounded by Louisiana Highway 71 on the west and U.S. Highway I-20 on the north.
Barksdale AFB is hosted by the 2d Bomb Wing and is currently home for a number of active duty and reserve component units, including Headquarters Eighth Air Force and the 917th Wing (Air Force Reserve Wing). Units within the 2d Bomb Wing include the 2d Operations
Group, the 2d Logistics Group, the 2d Support Group, and the 2d Medical Group.
Construction of the airfield began in 1931. Barksdale Field was formally dedicated on February 2, 1933, marking the culmination of concerted community action to bring the airfield to the Shreveport area. Weeklong activities in February 1993 marked the 60th anniversary of Barksdale AFB. This celebration included the acceptance of a National Registry of Historic Places certificate placing 264 buildings constructed between 1930 and 1938 in the Barksdale Field Historic District.
The current mission of the 2d Bomb Wing is to develop and maintain operational capability to conduct strategic warfare as an Air Force Global Strike Command Base. The primary assets of the Wing are three active Bomb Squadrons, each composed of B-52H bombers. The 2d Bomb Wing provides global combat capability and trains all B-52 combat crews.
The 917th Wing is a composite wing that operates and maintains both the A-10 Thunderbolt and the B-52H Stratofortress.
The addition of the B-52H to the 917th Wing and the removal of the KC-10 and KC-135 aerial refueling aircraft in 1994 have resulted in a number of changes in the maintenance facilities. On-going projects have focused on consolidating functions and expanding those facilities used by the 917th Wing. There are no other known new missions or planned changes that would significantly affect the current operations, support, personnel, or utility functions at Barksdale AFB.
As of June 2007, the population of Barksdale AFB included approximately 7,306 active and reserve military personnel as well as approximately 1,859 civilian employees. Some 6,141 dependents currently reside on Base.
(Attachment JA2 Natural Gas Distribution System Template – SEPTEMBER 2009_REV MAY 2010) User Edited: v07 07Feb11
JA2-3
JA2.2 Natural Gas Distribution System Description
JA2.2.1 Natural Gas Distribution System Fixed Equipment Inventory
The Barksdale AFB natural gas distribution system consists of all appurtenances physically connected to the distribution system from the point of demarcation defined by the Right of Access. The distribution system consists of the items listed in Table 1 “Fixed Inventory Natural Gas Distribution System” in Section JA2.2.1.2 Inventory. The actual inventory of items sold will be in the bill of sale at the time the system is transferred. The following description and inventory is included to provide the Offeror with a general understanding of the size and configuration of the distribution system. The Government makes no representation that the inventory is accurate. The Offeror shall base its proposal on the Table 1 inventory below. However, the Offeror should use the following reference points for developing other aspects of its proposal: site inspections, information in the technical library, and other pertinent information.
Specifically excluded from the natural gas distribution system privatization are:
All meters
Compressed natural gas stations
Military Family Housing (MFH)
Munitions Storage Area (MSA)
Flight Line
Clairborne Air Force Range
JA2.2.1.1 Description
Natural gas is currently supplied to Barksdale AFB by CenterPoint Energy-Arkla (Arkla) at four locations. Arkla high pressure mains are extended to Arkla owned and maintained metering and regulator stations near the base boundary. The pressure is regulated down to approximately 25 psig for distribution throughout the base. Distribution piping and equipment beyond these stations are owned, operated, and maintained by Barksdale AFB.
The average depth of burial of the system is three feet. The remaining original steel mains and service lines are protected by galvanic cell type cathodic protection systems with the exception of the steel mains within Capehart housing, which are protected, by an impressed current system. The amount of gas piping beneath pavement is roughly 5%. Tracer wire is routinely installed on PE pipe and warning tape has been installed approximately twelve inches above the pipes. System odorization is maintained by Arkla.
One of the four Arkla meter and regulator stations is located at the West Gate, in and adjacent to Building 1359. This station serves the main base and apron areas north of Wilbur Wright Drive. A second meter and regulator station is located in a fenced area along Louisiana Boulevard, across from Chapel 2, Building 4221. This station is referred to as the Chapel 2 station and services the main base area located to the south of Wilbur Wright Drive. The third meter and regulator station is located near the south end of the runway, (Attachment JA2 Natural Gas Distribution System Template – SEPTEMBER 2009_REV MAY 2010) User Edited: v07 07Feb11
JA2-4
west of Building 6850 in the vicinity of Mack’s Bayou. This station serves the Barksdale east facilities, NCO Academy Area, and the Munitions Storage Area (MSA). The fourth meter and regulator station is located south of Heritage Heights MFH at the intersection of Erwin Drive and Smith Drive. This station serves Heritage Heights, Capehart, and new housing being constructed in this area of Barksdale AFB.
JA2.2.1.2 Inventory
Table 1 provides a general list of the major natural gas distribution system fixed assets for the Barksdale AFB natural gas distribution system included in the sale. The design life column indicated in Table 1 is used by the Government in the development of the Government Should Cost Estimate. The design life is not mandated in the Offeror’s proposal. However, the proposal must clearly explain the use of any system component design life that significantly differs from the published Government design life.
TABLE 1
Fixed Inventory Natural Gas Distribution System
Item Size Quantity Unit Approximate Year of
Construction
Design Life (Years)
Steel Pipe, slip lined 12" 743 LF 2001 50
Steel Pipe 8" 3,352 LF 1938 50
PE Pipe, sliplined, changing to 4” 8" 1,447 LF 1999 75
PE Pipe 6" 691 LF 1999 75
PE Pipe 4" 22,743 LF 1999 75
PE Pipe 4" 1,400 LF 2004 75
PE Pipe 3" 6,934 LF 1999 75
PE Pipe 2" 21,471 LF 1999 75
PE Pipe 1.5" 550 LF 1999 75
PE Pipe 1.25" 3,369 LF 1999 75
PE Pipe 1" 9,563 LF 1999 75
PE Pipe 0.75" 11,928 LF 1999 75
PE Pipe 0.5" 227 LF 1999 75
Regulator 4" 1 EA 1999 20
Regulator 2" 2 EA 1999 20
Regulator 1.5" 8 EA 1999 20
Regulator 1" 148 EA 1999 20
Regulator 0.75" 7 EA 1999 20
Steel Plug Valve 3" 1 EA 1959 25
(Attachment JA2 Natural Gas Distribution System Template – SEPTEMBER 2009_REV MAY 2010) User Edited: v07 07Feb11
JA2-5
TABLE 1
Fixed Inventory Natural Gas Distribution System
Item Size Quantity Unit Approximate Year of
Construction
Design Life (Years)
Steel Plug Valve 1.25" 1 EA 1959 25
Steel Plug Valve 1" 1 EA 1959 25
PE Ball Valve 6" 2 EA 1999 30
PE Ball Valve 4" 39 EA 1999 30
PE Ball Valve 3" 54 EA 1999 30
PE Ball Valve 2" 53 EA 1999 30
PE Ball Valve 1.5" 7 EA 1999 30
PE Ball Valve 1.25" 6 EA 1999 30
PE Ball Valve 1" 76 EA 1999 30
PE Ball Valve 0.75" 12 EA 1999 30
Anode - Magnesium 48 lbs 56 EA 1980 15
Anode - Magnesium 17 lbs 32 EA 1986 15
Test Station - 7 EA 1980 20
Test Station - 4 EA 1986 20
Handhole, Concrete 1' x 2' x 1'9" 3 EA 1959 60
Handhole, Concrete 1' x 2' x 1'9" 249 EA 1999 60
Notes:
PE = polyethylene lf = linear feet ea = each in = inches psi = pounds per square inch
JA2.2.2 Natural Gas Distribution System Non-Fixed Equipment and Specialized Tools
Table 2 lists other ancillary equipment (spare parts) and Table 3 lists specialized vehicles and tools included in the purchase. Offeror shall field verify all equipment, vehicles, and tools prior to submitting a bid. Offeror shall make its own determination of the adequacy of all equipment, vehicles, and tools.
(Attachment JA2 Natural Gas Distribution System Template – SEPTEMBER 2009_REV MAY 2010) User Edited: v07 07Feb11
JA2-6
TABLE 2
Spare Parts Natural Gas Distribution System
Item Make/Model Description Quantity Remarks
None
TABLE 3
Specialized Vehicles and Tools Natural Gas Distribution System
Item Make/Model Description Quantity Remarks
JA2.2.3 Natural Gas Distribution System Manuals, Drawings, and Records
Table 4 lists the manuals, drawings, and records that will be transferred with the system.
TABLE 4
Manuals, Drawings, and Records Natural Gas Distribution System
Item Description Quantity Remarks
FY 09 Utility Bills Historical Bills 1
Barksdale AFB Cathodic Protection System Drawings
Cathodic Protection System Record Drawings 1 Must be field verified
Barksdale AFB 5-Year Natural Gas Plan
Published Document 1
Barksdale AFB General Plan
Published Document 1
Barksdale AFB Gas System Drawings
Gas System Record Drawings 1 Must be field verified
Barksdale AFB Housing Easements
GIS document showing locations of Housing GIS Coordinates as shown in Table 11, below.
1 Current Version to be provided to SO
JA2.3 Specific Service Requirements
Service requirements for this natural gas distribution system are as defined in the RFP Section C, Description/Specifications/Work Statement. The following requirements are specific to the base natural gas distribution system and are in addition to those found in Section C.
1. The Government will provide the electricity, natural gas, and water commodities and the wastewater collection required to operate and maintain the systems being
(Attachment JA2 Natural Gas Distribution System Template – SEPTEMBER 2009_REV MAY 2010) User Edited: v07 07Feb11
JA2-7
privatized at no cost to the System Owner (SO). The Government will also provide any infrastructure necessary to connect the facilities required to operate and maintain the systems being privatized to electricity, natural gas, water, and wastewater collection services at no cost to the SO. If fuel oil or propane is required to operate emergency generators, purchase and supply of that fuel oil or propane will be the responsibility of the SO.
JA2.4 Current Service Arrangement
CenterPoint Energy-Arkla supplies natural gas to the base through their high pressure mains extended to four meter and regulator stations located near the base boundary. The
FY09 Annual Usage is 174,106 MCF for Barksdale AFB (excluding MFH).
JA2.5 Metering
JA2.5.1 Existing Meters
Table 5 provides a list of the existing (at the time of contract award) meters that will be transferred to the SO. The SO shall provide meter monthly readings for all meters listed below.
TABLE 5
Existing Meters Natural Gas Distribution System
Meter Location Meter Size Remarks
JA2.5.2 Required New Meters
The SO shall install and calibrate new meters as listed in Table 6.
TABLE 6
Required New Meters Natural Gas Distribution System
Meter Location Meter Size Remarks
None
JA2.6 Monthly Submittals
The SO shall provide the Government with monthly submittals for the following:
1. Outage Report. The SO’s monthly outage report will be prepared in the format proposed by the SO and accepted by the Contracting Officer. Outage reports shall be submitted by the 25th of each month for the previous month. Outage reports shall be submitted to:
(Attachment JA2 Natural Gas Distribution System Template – SEPTEMBER 2009_REV MAY 2010) User Edited: v07 07Feb11
JA2-8
Organization/Office Symbol: Utility Contract Administrator Address: 841 Fairfield Ave, Suite 105 Barksdale AFB, LA 71110-2075
Phone number: (318) 456-6833
JA2.7 Energy-Savings Projects
The following projects listed in Table 7 have been implemented on the distribution system by the Government for energy conservation purposes.
TABLE 7
Energy-Savings Projects Natural Gas Distribution System
Project Location Project Description
JA2.8 Service Area
The current service area is defined as all areas within the Barksdale AFB boundaries, except as specifically excluded in Section JA2.2.1.
JA2.9 Off-Installation Sites
No off-installation sites are included in the sale of the Barksdale AFB natural gas distribution system.
JA2.10 Specific Transition Requirements
Table 8 provides a list of service connections and disconnections required upon transfer.
TABLE 8
Service Connections and Disconnections Natural Gas Distribution System
Location Description
None
JA2.11 Initial System Deficiency Corrections (ISDC)
Table 9 provides a list of ISDC projects the Government has planned for this system. The Government recognizes these projects represent current deficiencies associated with the system. If the system is sold, the Government will not accomplish these projects. The SO shall determine the actual need and timing of any and all such projects.
(Attachment JA2 Natural Gas Distribution System Template – SEPTEMBER 2009_REV MAY 2010) User Edited: v07 07Feb11
JA2-9
TABLE 9
Initial System Deficiency Corrections Natural Gas Distribution System
Project Location Project Description
None
JA2.12 Right of Access to the Utility System
No leased property was identified with the Natural Gas Distribution system.
JA2.12.1 Map of the Utility System
Maps from the Base Comprehensive Plan or other drawings show the known locations of the utility system and are available in the technical library at the base civil engineer organization. Portions of the utility system may not be fully shown on the map or maps.
Any such failure to show the complete utility system on the map or maps shall not be interpreted as that part of the utility system being outside the Installation. The Installation is co-extensive with the entire linear extent of the utility system sold to Grantee (SO), whether or not precisely shown on the map or maps.
JA2.12.2 Lateral Extent of the Right-of-Access, and Points of Demarcation
JA2.12.2.1 Lateral Extent of Utility System Right-of-Access
For pipe sizes of 24 inches in diameter or less, the lateral extent of the Right-of-Access is defined as 26-feet wide, extending 13 feet on each side of the utility system, as installed.
For pipe sizes greater than 24 inches in diameter, the lateral extent of the Right-of-Access is defined as 50-feet wide, extending 25 feet on each side of the utility system, as installed.
JA2.12.2.2 Utility System Points of Demarcation
The point of demarcation (POD) is defined as the point on the utility system where ownership changes from the utility SO to the facility owner. Table 10 identifies the type and general location of the point of demarcation with respect to the facility for each scenario.
(Attachment JA2 Natural Gas Distribution System Template – SEPTEMBER 2009_REV MAY 2010) User Edited: v07 07Feb11
JA2-10
TABLE 10
Standard Points of Demarcation Natural Gas Distribution System
Point of Demarcation Applicable Scenario Sketch
POD is the upstream side of the meter.
Service to the structure is metered.
POD is the downstream side of the regulator.
Service to the structure is regulated but not metered.
POD is the downstream side of the closest apparatus to the exterior of the structure unless the closest apparatus is a meter. If a meter is present, the POD is the upstream side of the meter.
More than one apparatus is connected to the service line feeding the structure.
POD is the upstream side of the closest shutoff valve to the exterior of the structure.
No meter or regulator is connected to the service line feeding the structure.
WITHIN HOUSING AREAS
POD is the upstream side of the meter.
Residential structure.
Service to the structure is metered.
Structure
Service Line
Meter
Point of Demarcation
Distribution Line
Distribution Line
Pressure regulator or valve
Structure
Service Line
Point of Demarcation
Distribution Line
Distribution Line Shutoff Valve
Customer Valve
Structure
Service Line
Meter Point of Demarcation
Distribution Line
Distribution Line Pressure Regulator
Structure
Service Line
Point of Demarcation
Distribution Line
Distribution Line Pressure Regulator
Structure
Service Line
Meter Point of Demarcation
Distribution Line
(Attachment JA2 Natural Gas Distribution System Template – SEPTEMBER 2009_REV MAY 2010) User Edited: v07 07Feb11
JA2-11
TABLE 10
Standard Points of Demarcation Natural Gas Distribution System
Point of Demarcation Applicable Scenario Sketch
WITHIN HOUSING AREAS
POD is the downstream side of the closest pressure regulator or valve to the structure.
Residential structure.
Service to the structure is not metered.
Note: If a meter is installed in the future, then the POD becomes the upstream side of the meter.
Table 11 lists anomalous “unique” points of demarcation that do not fit any of the above scenarios. These unique points of demarcation shall take precedence over the standard points of demarcation shown in Table 10.
TABLE 11
Unique Points of Demarcation Natural Gas Distribution System
Location POD Description
MSA POD is the downstream side of Regulator Number 01 located West of Ammo Rd.
Flight Line POD is the downstream side of Valve Number 430 located Northwest of Building 7705
Flight Line POD is where 3 inch polyethylene main line crosses the North-South security fence line. Fence location is north of Building 6842
Flight Line - Bldg 6850 POD is downstream side of Valve Number 602
Flight Line – Bldg 6836 POD is downstream side of Valve Number 603
Flight Line – Bldg 6830 POD is downstream side of Valve Number 604
Flight Line – Bldg 6826 POD is downstream side of Valve Number 605
Flight Line POD is North side of Valve Number 611, East of Building 6815
Flight Line POD is East side of Valve Number 614
Flight Line POD is West side of Valve Number 624
Flight Line POD is downstream side of Valve Number 623
Flight Line POD is North side of Valve Number 625
Flight Line – Bldg 6448 POD is downstream of un-numbered valve located South of Bldg 6448
Flight Line – Bldg 6426 POD is downstream side of Valve Number 512
Structure
Service Line
Point of Demarcation
Distribution Line
Pressure regulator or valve
(Attachment JA2 Natural Gas Distribution System Template – SEPTEMBER 2009_REV MAY 2010) User Edited: v07 07Feb11
JA2-12
TABLE 11
Unique Points of Demarcation Natural Gas Distribution System
Location POD Description
Flight Line – Bldg 6426 POD is downstream side of Valve Number 513
Flight Line – Bldg 6226 POD is downstream side of Valve Number 539
Flight Line – Bldg 6215 POD is downstream side of Valve Number 541
Flight Line – Bldg 6214 POD is downstream side of Valve Number 543
Flight Line – Bldg 6200 POD is downstream side of Valve Number 544
Flight Line POD is where 2 inch polyethylene main line crosses the North-South security fence line located north of Building 6200
Historical West Housing POD is Barksdale AFB side of line at GIS Coordinates
435675.883647
3596203.68614
Historical West Housing POD is Barksdale AFB side of line at GIS Coordinates
435778.967655
3596260.54265
Historical West Housing POD is Barksdale AFB side of line at GIS Coordinates
435863.573775
3596304.84622
Historical West Housing POD is Barksdale AFB side of line at GIS Coordinates
435994.571792
3596375.25553
Historical West Housing POD is Barksdale AFB side of line at GIS Coordinates
436141.633492
3596685.32643
Historical West Housing POD is Barksdale AFB side of line at GIS Coordinates
436102.627225
3596906.25447
Historical West Housing POD is Barksdale AFB side of line at GIS Coordinates
435924.058054
3596890.42592
Historical West Housing POD is Barksdale AFB side of line at GIS Coordinates
435907.239689
3596979.5896
Historical East Housing POD is Barksdale AFB side of line at GIS Coordinates
435747.966345
3596124.59003
(Attachment JA2 Natural Gas Distribution System Template – SEPTEMBER 2009_REV MAY 2010) User Edited: v07 07Feb11
JA2-13
Natural Gas Distribution System
Location POD Description
Historical East Housing POD is Barksdale AFB side of line at GIS Coordinates
435751.534334
3596141.22252
Historical East Housing POD is Barksdale AFB side of line at GIS Coordinates
435900.779623
3596255.55045
Historical East Housing POD is Barksdale AFB side of line at GIS Coordinates
436081.059308
3596279.45714
Historical East Housing POD is Barksdale AFB side of line at GIS Coordinates
436363.544808
3596272.8667
Historical East Housing POD is Barksdale AFB side of line at GIS Coordinates
436538.56521
3596095.50363
Historical East Housing POD is Barksdale AFB side of line at GIS Coordinates
436602.995663
3595956.9623
Historical East Housing POD is Barksdale AFB side of line at GIS Coordinates
436576.075036
3595948.3187
Historical East Housing POD is Barksdale AFB side of line at GIS Coordinates
436513.500037
3596004.13934
Historical East Housing POD is Barksdale AFB side of line at GIS Coordinates
436478.57666
3596021.95781
Historical East Housing POD is Barksdale AFB side of line at GIS Coordinates
436345.665477
3596008.7298
Historical East Housing POD is at downstream side of Valve Number MBG102, located East of Building Number 3720
Capehart Housing POD is Barksdale AFB side of line at GIS Coordinates
443972.944896
3597748.06458
(Attachment JA2 Natural Gas Distribution System Template – SEPTEMBER 2009_REV MAY 2010) User Edited: v07 07Feb11
JA2-14
Natural Gas Distribution System
Location POD Description
Capehart Housing POD is Barksdale AFB side of line at GIS Coordinates
443954.651969
3597490.01503
Heritage Heights Housing POD is Barksdale AFB side of line at GIS Coordinates
444049.978228
33598992.27271
West Gate POD is downstream side of Arkla’s meter located adjacent to Building Number 1359
Louisiana Boulevard POD is downstream side of Arkla’s meter located across from Chapel 2, Building 4221
Note: For ”POD at --- GIS Coordinates” numbering references Base provided GIS document: housing_ eEasements_60x60.pdf
JA2.12.3 Environmental Baseline Survey
The Air Force has determined that it is not required to conduct an EBS in regard to the sale of this utility system.