Global_RLP_Form R100 (8MD2389 - Hyattsville)(Full Package).pdf

PDF 2 MB Posted

Attached to
General Services Administration (GSA) seeks to lease the following space:
Solicitation number
8md2389
Issued by

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

GSA FORM R100 (02/20)

GSA REQUEST

FOR LEASE

PROPOSALS

NO. 8MD2389

HYATTSVILLE,

MD

Offers due by 09/03/2020

In order to be considered for award, offers conforming to the requirements of the RLP shall be received no later than 4:00 PM EST on the date above. See “Receipt Of Lease Proposals” herein for additional information.

This Request for Lease Proposals ("RLP") sets forth instructions and requirements for proposals for a Lease described in the RLP documents. Proposals conforming to the RLP requirements will be evaluated in accordance with the Method of Award set forth herein to select an Offeror for award. The Government will award the Lease to the selected Offeror, subject to the conditions herein.

The information collection requirements contained in this Solicitation/Contract, that are not required by the regulation, have been approved by the Office of Management and Budget pursuant to the Paperwork Reduction Act and assigned the OMB Control No. 3090-0163.

GLOBAL RLP

TABLE OF CONTENTS

GLOBAL RLP

SECTION 1 STATEMENT OF REQUIREMENTS

1.01 GENERAL INFORMATION (SEP 2015)

1.02 AMOUNT AND TYPE OF SPACE, LEASE TERM, AND OCCUPANCY DATE (OCT 2016)

1.03 AREA OF CONSIDERATION (JUN 2012)

1.04 UNIQUE REQUIREMENTS (OCT 2016)

1.05 NEIGHBORHOOD, PARKING, LOCATION AMENITIES, AND PUBLIC TRANSPORTATION (DEC 2015)

1.06 LIST OF RLP DOCUMENTS (OCT 2019)

1.07 AMENDMENTS TO THE RLP (JUN 2012)

1.08 LEASE DESCRIPTION (OCT 2016)

1.09 RELATIONSHIP OF RLP BUILDING MINIMUM REQUIREMENTS AND LEASE OBLIGATIONS (OCT 2016)

1.10 PRICING OF SECURITY REQUIREMENTS (OCT 2016)

1.11 SECURITY LEVEL DETERMINATION FOR FACILITY HOUSING OTHER FEDERAL TENANTS (APR 2011)

1.12 INSPECTION—RIGHT OF ENTRY (JUN 2012)

1.13 AUTHORIZED REPRESENTATIVES (JUN 2012)

1.14 BROKER COMMISSION AND COMMISSION CREDIT (SEP 2013)

1.15 NORTH AMERICAN INDUSTRY CLASSIFICATION SYSTEM (NAICS) CODE AND SMALL BUSINESS SIZE

STANDARD (OCT 2019)

1.16 DUNS NUMBER (OCT 2017)

SECTION 2 ELIGIBILITY AND PREFERENCES FOR AWARD

2.01 EFFICIENCY OF LAYOUT (AUG 2011)

2.02 FLOOD PLAINS (OCT 2017)

2.03 SEISMIC SAFETY – MODERATE SEISMICITY (OCT 2017) INTENTIONALLY DELETED

2.04 SEISMIC SAFETY – HIGH SEISMICITY (OCT 2017) INTENTIONALLY DELETED

2.05 HISTORIC PREFERENCE (SEP 2013)

2.06 ASBESTOS (JUN 2012)

2.07 ACCESSIBILITY (SEP 2013)

2.08 FIRE PROTECTION AND LIFE SAFETY (SEP 2013)

2.09 ENERGY INDEPENDENCE AND SECURITY ACT (OCT 2016)

2.10 ENVIRONMENTAL CONSIDERATIONS (SEP 2013)

2.11 DUE DILIGENCE AND NATIONAL ENVIRONMENTAL POLICY ACT REQUIREMENTS - RLP (SEP 2014)

2.12 NATIONAL HISTORIC PRESERVATION ACT REQUIREMENTS - RLP (OCT 2016)

SECTION 3 HOW TO OFFER

3.01 GENERAL INSTRUCTIONS (JUN 2012)

3.02 RECEIPT OF LEASE PROPOSALS (OCT 2019)

3.03 PRICING TERMS (JUL 2020)

3.04 BUDGET SCOREKEEPING; OPERATING LEASE TREATMENT (APR 2011)

3.05 PROSPECTUS LEASE (OCT 2016) INTENTIONALLY DELETED

3.06 ADDITIONAL SUBMITTALS (FEB 2020)

3.07 TENANT IMPROVEMENTS INCLUDED IN OFFER (SEP 2015)

3.08 TURNKEY PRICING WITH DESIGN INTENT DRAWINGS PRIOR TO AWARD (OCT 2017) INTENTIONALLY

DELETED

3.09 SECURITY IMPROVEMENTS INCLUDED IN OFFER (OCT 2016)

3.10 GREEN BUILDING RATING CERTIFICATION FOR TENANT INTERIORS (OCT 2016)

INTENTIONALLY DELETED

3.11 OPERATING COSTS REQUIREMENTS INCLUDED IN OFFER (JUN 2012)

3.12 UTILITIES SEPARATE FROM RENTAL / BUILDING OPERATING PLAN (JUN 2012) INTENTIONALLY DELETED 16

SECTION 4 METHOD OF AWARD

4.01 NEGOTIATIONS (JUN 2012)

4.02 HUBZONE SMALL BUSINESS CONCERN ADDITIONAL PERFORMANCE REQUIREMENTS (SEP 2015)

4.03 AWARD BASED ON PRICE (JUN 2012)

4.04 OTHER AWARD FACTORS (OCT 2016) INTENTIONALLY DELETED

4.05 FACTOR DESCRIPTIONS (OCT 2016) INTENTIONALLY DELETED

4.06 FACTOR MINIMUM STANDARDS (OCT 2016) INTENTIONALLY DELETED

4.07 FACTOR SUBMITTAL REQUIREMENTS (OCT 2016) INTENTIONALLY DELETED

4.08 DOCUMENTATION REQUIREMENTS (OCT 2016) INTENTIONALLY DELETED

4.09 PRESENT VALUE PRICE EVALUATION (OCT 2016)

4.10 AWARD (OCT 2018)

SECTION 5 ADDITIONAL TERMS AND CONDITIONS

5.01 AWARD WITHOUT DISCUSSION

5.02 MODIFIED RLP PARAGRAPHS (OCT 2016)

RLP NO. 8MD2389, PAGE 1 GSA FORM R100 (02/20)

REQUEST FOR LEASE

PROPOSALS NO. 8MD2389

8/13/2020

GLOBAL RLP GSA FORM R100 (FEB 2020)

SECTION 1 STATEMENT OF REQUIREMENTS

1.01 GENERAL INFORMATION (SEP 2015)

A. This Request for Lease Proposals (RLP) sets forth instructions and requirements for proposals for a Lease described in the RLP documents. The Government will evaluate proposals conforming to the RLP requirements in accordance with the Method of Award set forth below to select an Offeror for award. The Government will award the Lease to the selected Offeror, subject to the conditions below.

B. Included in the RLP documents is a lease form (GSA Form L100) setting forth the lease term and other terms and conditions of the Lease contemplated by this RLP and a GSA Proposal to Lease Space (GSA Form 1364) on which Offeror shall submit its offered rent and other price data, together with required information and submissions. The Lease paragraph titled “Definitions and General Terms” shall apply to the terms of this RLP.

C. Do not attempt to complete the lease form (GSA Form L100). Upon selection for award, GSA will transcribe the successful Offeror’s final offered rent and other price data included on the GSA Form 1364 into the lease form, and transmit the completed Lease, including any appropriate attachments, to the successful Offeror for execution. Neither the RLP nor any other part of an Offeror’s proposal shall be part of the Lease except to the extent expressly incorporated therein. The Offeror should review the completed Lease for accuracy and consistency with his or her proposal, sign and date the first page, initial each subsequent page of the Lease, and return it to the Lease Contracting Officer (LCO).

D. The Offeror's executed Lease shall constitute a firm offer. No Lease shall be formed until the LCO executes the Lease and delivers a signed copy to the Offeror.

1.02 AMOUNT AND TYPE OF SPACE, LEASE TERM, AND OCCUPANCY DATE (OCT 2016)

A. The Government is seeking a minimum of 10,800 to a maximum of 11,340 of American National Standards Institute/Building Owners and Managers Association (ANSI/BOMA) Office Area (ABOA) square feet (SF) of contiguous space within the Area of Consideration set forth below. See Section 2 of the Lease for applicable ANSI/BOMA standards.

B. The Space shall be located in a modern quality Building of sound and substantial construction with a facade of stone, marble, brick, stainless steel, aluminum or other permanent materials in good condition and acceptable to the LCO. If not a new Building, the Space offered shall be in a Building that has undergone, or will complete by occupancy, modernization or adaptive reuse for the Space with modern conveniences.

C. The Government requires 0 structured/inside parking spaces and 0 surface/outside parking spaces, reserved for the exclusive use of the Government. These spaces must be secured and lit in accordance with the Security Requirements set forth in the Lease.

Offeror shall include the cost of this parking as part of the rental consideration.

D. As part of the rental consideration, the Government may require use of part of the Building roof for the installation of antenna(s).

If antenna space is required, specifications regarding the type of antenna(s) and mounting requirements are included in the agency requirements information provided with this RLP.

E. Approximately 250 ABOA SF will be used for the operation of a vending facility under the provisions of the Randolph-Sheppard Act (20 USC 107 et. seq.). The Government will control the number, kind, and locations of vending facilities and will control and receive income from all automatic vending machines. Offeror shall provide necessary utilities and make related alterations. The cost of the improvements is part of Tenant Improvement (TI) costs. The Government will not compete with other facilities having exclusive rights in the Building. The Offeror shall advise the Government if such rights exist.

F. The Government may provide vending machines within the Government's leased area under the provisions of the Randolph- Sheppard Act (20 USC 107 et. seq.). If the Government chooses to provide vending facilities, the Government will control the number, kind, and locations of vending facilities and will control and receive income from all automatic vending machines. Offeror shall provide necessary utilities and make related alterations. The cost of the improvements is part of Tenant Improvement (TI) costs. The Government will not compete with other facilities having exclusive rights in the Building. The Offeror shall advise the Government if such rights exist.

G. The lease term shall be 15 Years, 15 Years Firm. This Lease may be renewed at the option of the Government for one, five (5) year terms. The Government reserves the right in the Lease to not include an option, or to reduce the length of an option, if inclusion of the option would cause the Lease to score as a capital lease, in accordance with the Budget Scorekeeping: Operating Lease Treatment paragraph of this RLP. Should the Government make the determination to modify the term or option(s), an amendment to the RLP will be issued.

RLP NO. 8MD2389, PAGE 2 GSA FORM R100 (02/20)

1.03 AREA OF CONSIDERATION (JUN 2012)

The Government requests Space in an area bounded as follows:

Hyattsville, MD, from the intersection of East West Highway and Adelphi Road:

North on Adelphi Road to Belcrest Road, Southwest on Belcrest Road to Toledo Terrace, West on Toledo Terrace to East West Highway, East on East West Highway to Adelphi Road

Buildings that have frontage on the boundary streets are deemed to be within the delineated Area of Consideration.

1.04 UNIQUE REQUIREMENTS (OCT 2016)

The offered Building and/or Property must have the following features:

A. Offered space must be contiguous and located on a single floor above grade.

1.05 NEIGHBORHOOD, PARKING, LOCATION AMENITIES, AND PUBLIC TRANSPORTATION (DEC 2015)

A. Neighborhood and Parking: Outside City Center:

Space shall be located 1) in an office, research, technology, or business park that is modern in design with a campus-like atmosphere; or, 2) on an attractively landscaped site containing one or more modern office Buildings that are professional and prestigious in appearance with the surrounding development well maintained and in consonance with a professional image. The parking-to-square-foot ratio available on-site shall at least meet current local code requirements, or, in the absence of a local code requirement, on-site parking shall be available at a ratio of one (1) space for every 500 RSF of Space.

B. Walkability and Amenities:

1. Employee and visitor entrances of the Building must be connected to public sidewalks by continuous, accessible sidewalks.

2. A variety of employee services, such as restaurants, retail shops, cleaners, and banks, shall be located within the immediate vicinity of the Building. The primary functional entrance of the Building shall be within safely accessible, walkable 2,640 foot distance of at least seven (7) instances of amenities, two of which must be inexpensive or moderately priced fast-food or eat-in restaurants. The remaining five (5) instances must fall within at least 2 of the Diverse Use Categories shown below:

Diverse Use Category Uses Food Retail Supermarket, Other food store with produce Community-Serving Retail Clothing store or department store selling clothes, Convenience store, Farmer’s market, Hardware store, Pharmacy, Other retail

Services Bank, Gym, Health club, Exercise studio, Hair care, Laundry, Dry cleaner, Restaurant, Café, Diner (excluding establishments with only drive-throughs)

Civic and Community Facilities Adult or senior care (licensed), Child care (licensed), Community or recreation center, Cultural arts facility (museum, performing arts), Educational facility (including K–12 school, university, adult education center, vocational school, community college), Family entertainment venue (theater, sports), Government office that serves public on-site, Place of worship, Medical clinic or office that treats patients, Police or fire station, Post office, Public library, Public park, Social services center

To be considered, amenities must be accessible from the Building by continuous sidewalks, walkways, or pedestrian crosswalks.

Amenities must be existing or the Offeror must demonstrate to the Government’s reasonable satisfaction that such amenities will exist by the Government’s required occupancy date.

D. Transit Accessibility: A subway, light rail, or bus rapid transit stop shall be located within the immediate vicinity of the Building, but generally not exceeding a safely accessible, walkable 2,640 feet from the principal functional entrance of the building, as determined by the LCO.

1.06 LIST OF RLP DOCUMENTS (OCT 2019)

The following documents are attached to and included as part of this RLP package:

RLP NO. 8MD2389, PAGE 3 GSA FORM R100 (02/20)

DOCUMENT NAME

NO. OF

PAGES

EXHIBIT

Lease No. GS-XXP-LMDXXXXX (Form L100) 42 A Security Requirements for Level III 14 B GSA Form 3516, Solicitation Provisions 5 C GSA Form 3517B, General Clauses 17 D Proposal to Lease Space (GSA Form 1364) 3 E Attachment #2 to 1364 – Routine Cleaning and Disinfecting Requirements

1 F

GSA Form 1217, Lessor's Annual Cost Statement 2 G GSA Form 12000 for Prelease Fire Protection and Life Safety Evaluation for an Office Building (Part A or Part B) (See Section 3 for applicable requirements)

6 H

Small Business Subcontracting Plan 18 I Commission Agreement 3 J Security – Facility Management Worksheet 7 K Security – Engineer Worksheet 16 L Covered Telecommunications Equipment or Services Representation

2 M

1.07 AMENDMENTS TO THE RLP (JUN 2012)

This RLP may be amended by notice from the LCO. Amendments may modify the terms of this RLP, or the terms, conditions, and requirements of the Lease contemplated by the RLP.

1.08 LEASE DESCRIPTION (OCT 2016)

A. Offeror shall examine the Lease form included in the RLP documents to understand the Government's and the Lessor's respective rights and responsibilities under the contemplated Lease.

B. The Lease contemplated by this RLP includes:

1. The term of the Lease, and renewal option, if any.

2. Terms and Conditions of the Lease, including Definitions, Standards, and Formulas applicable to the Lease and this RLP.

3. Building Shell standards and requirements.

4. Information concerning the tenant agency's buildout requirements, to be supplemented after award.

5. Security Requirements.

6. A description of all services to be provided by the Lessor.

C. Should the Offeror be awarded the Lease, the terms of the Lease shall be binding upon the Lessor without regard to any statements contained in this RLP.

D. The Lease contemplated by this RLP is a fully serviced Lease. Rent shall be based upon a proposed rental rate per Rentable Square Foot (RSF), limited by the offered rate and the maximum ABOA SF solicited under this RLP. Although certain Tenant Improvement (TI) requirements information is provided with this RLP and will be incorporated into the Lease, the TIs to be delivered by the Lessor will be based on the final design to be developed after award of the Lease, which reflects the Agency’s full requirements.

The Lessor shall design and build the TIs and will be compensated for TI costs, together with design and project management fees to be set under the Lease. Although the TI requirements will not be developed fully until after award, Offerors shall provide the allowance stated in the Tenant Improvement Allowance paragraph of the Lease.

Unless the Government prepares Design Intent Drawings (DIDs), after award the Lessor must prepare DIDs for the leased Space conforming to the lease requirements and other Government-supplied information related to the client agency’s interior build-out requirements. The Government will have the opportunity to review the Lessor's DIDs to determine that the Lessor's design meets the requirements of the Lease. Only after the Government approves the DIDs and a final price for TIs is negotiated will the Lessor be released to proceed with buildout. The Lease also provides that the Government may modify the TI requirements, subject to the Lessor's right to receive compensation for such changes.

E. The security pricing process is described in a separate paragraph.

F. Upon completion and acceptance of the leased Space, the Space will be measured for establishing the actual annual rent, and the lease term shall commence. During the term of the Lease, rent will be adjusted for changes to the Lessor's operating costs and real estate taxes, pursuant to paragraphs set forth in Section 2 of the Lease.

G. Offerors are advised that doing business with the Government carries special responsibilities with respect to sustainability, fire protection and life safety, and security, as well as other requirements not typically found in private commercial leases. These are set forth both in the lease form and in the GSA Form 3517B, which will be part of the Lease.

RLP NO. 8MD2389, PAGE 4 GSA FORM R100 (02/20)

1.09 RELATIONSHIP OF RLP BUILDING MINIMUM REQUIREMENTS AND LEASE OBLIGATIONS (OCT 2016)

The Lease establishes various requirements relating to the Building shell. Such requirements are not deemed TIs. There are certain Building requirements that are established as minimum requirements in this RLP. If the Lessor's Building does not meet the requirements at the time of award, the Lessor may still be awarded the Lease. However, as a condition of award, the Government will require Lessor to identify those Building improvements that will bring the Building into compliance with RLP requirements. Upon award of the Lease, completion of those Building improvements will become Lease obligations.

1.10 PRICING OF SECURITY REQUIREMENTS (OCT 2016)

A. The proposed Lease contains an attachment with the security requirements and obligations for the Building, which are based on the facility security level (FSL). The Federal Government determines the facility’s FSL rating, which ranges from FSL I to FSL IV.

The FSL is based on client agency mix, required size of space, number of employees, use of the space, location, configuration of the site and lot, and public access into and around the facility.

B. The security requirements attached to this Lease includes a general list of countermeasures that may be installed in the leased Space as part of the Building Specific Amortized Capital (BSAC). The final list of security countermeasures will be determined during the design phase and identified in the design intent drawings and construction documents. After completing the construction documents, the Lessor shall submit a list of the itemized costs. Such costs shall be subject to negotiation.

C. There shall be no charge to the Government for any items that already exist in the offered Building or facility.

1.11 SECURITY LEVEL DETERMINATION FOR FACILITY HOUSING OTHER FEDERAL TENANTS (APR 2011)

If an Offeror is offering Space in a facility currently housing a Federal agency, the security requirements of the facility may be increased and the Offeror may be required to adhere to a higher security standard than other Offerors competing for the same space requirement.

If two or more Federal space requirements are being competed at the same time, an Offeror submitting on both or more space requirements may be subject to a higher security standard if the Offeror is determined to be the successful Offeror on more than one space requirement. It is incumbent upon the Offeror to prepare the Offeror’s proposal accordingly.

1.12 INSPECTION—RIGHT OF ENTRY (JUN 2012)

A. At any time and from time to time after receipt of an offer (until the same has been duly withdrawn or rejected), the agents, employees and contractors of the Government may, upon reasonable prior notice to Offeror, enter upon the offered Space or the Premises, and all other areas of the Building access to which is necessary to accomplish the purposes of entry, to determine the potential or actual compliance by the Offeror with the requirements of the RLP and its attachments, which purposes shall include, but not be limited to:

1. Inspecting, sampling, and analyzing of suspected asbestos-containing materials and air monitoring for asbestos fibers.

2. Inspecting the heating, ventilation and air conditioning system, maintenance records, and mechanical rooms for the offered Space or the Premises.

3. Inspecting for any leaks, spills, or other potentially hazardous conditions which may involve tenant exposure to hazardous or toxic substances.

4. Inspecting for any current or past hazardous waste operations, to ensure that appropriate actions were taken to alleviate any environmentally unsound activities in accordance with Federal, state, and local law.

B. Nothing in this paragraph shall be construed to create a Government duty to inspect for toxic materials or to impose a higher standard of care on the Government than on other lessees. The purpose of this paragraph is to promote the ease with which the Government may inspect the Building. Nothing in this paragraph shall act to relieve the Offeror of any duty to inspect or liability which might arise because of Offeror’s failure to inspect for or correct a hazardous condition.

1.13 AUTHORIZED REPRESENTATIVES (JUN 2012)

With respect to all matters relating to this RLP, only the Government's LCO designated below shall have the authority to amend the RLP and award a Lease. The Government shall have the right to substitute its LCO by notice, without an express delegation by the prior LCO.

Lease LCO:

Sylva Nicolas Lease Contracting Officer U.S. General Services Administration 1800 F Street, NW Washington, DC 20006 Office: 202-538-9147 sylva.nicolas@gsa.gov

RLP NO. 8MD2389, PAGE 5 GSA FORM R100 (02/20)

As to all other matters, Offerors may contact the Alternate Government Contact designated below.

Alternate Government Contact:

Todd Valentine Savills, Inc.

1201 F Street, NW, Suite 500 Washington, DC 20004

202-624-8531 todd.valentine@gsa.gov

Bryant Porter Savills, Inc.

1201 F Street, NW, Suite 500 Washington, DC 20004

202-624-8515 bryant.porter@gsa.gov

1.14 BROKER COMMISSION AND COMMISSION CREDIT (SEP 2013)

A. For the purposes of this RLP, SAVILLS, INC. (the Broker) is the authorized contractor real estate broker representing GSA.

Offerors are advised that there is a potential for a dual agency situation to arise under this procurement, whereby the Broker may represent both GSA and another Offeror under this lease action. By submitting an offer, the Offeror acknowledges the potential for a dual agency situation. Should there be an actual dual agency, the Broker will notify all Offerors of the actual dual agency and request written acknowledgement statements from all Offerors. The Government expects the Lessor to pay a commission to the Broker. By submitting an offer, the Offeror agrees that if the Offeror is paying a commission or fee in connection with this Lease to a listing agent, an offering agent, or broker, property manager, developer, or any other agent or representative, then the Offeror will pay a commission to the Broker to which the Broker would ordinarily be entitled consistent with local business practices, as evidenced through a brokerage agreement between the Offeror and the Broker. The commission will be negotiated between the Offeror and the Broker and will be based on a Lease term not to exceed the Firm Term of the Lease contemplated by this RLP. Commissions will not be negotiated or collected on option periods or for Lease terms beyond the Firm Term of the Lease. As part of the offer, the Offeror shall disclose all commissions and/or fees to be paid by the Offeror including both the Offeror’s agent(s), broker(s), property manager, developer or any other agent or representative and the Broker. The Offeror shall enter the commission amounts for its representative and the amount to GSA’s Broker in blocks 31a and 31b respectively on GSA Form 1217, Lessors Annual Cost Statement. An executed commission agreement reflecting this agreement shall be submitted with the initial offer.

B. For the benefit of the Government, the Broker has agreed to forego a percentage of any commission that it is entitled to receive in connection with the contemplated Lease. This amount shall be specifically set forth at time of lease award. The resulting total dollar value of the foregone commission (the Commission Credit) shall be applied in equal monthly amounts against rental payments due and owing under the Lease. The rental amount payable shall be reduced by the Commission Credit at the commencement of the Lease, over the minimum number of months that will not exceed the monthly shell rental, until the Commission Credit has been fully recaptured. The parties agree to execute a Lease Amendment setting forth the full nature, extent, terms, and conditions of commissions paid to the Broker and the Commission Credit to be applied against the Government’s rental payment obligations under the Lease. Commissions and/or credits shall be treated as confidential financial information and Offerors will refrain from public disclosure or using the information for any other purpose than that for which it was furnished without consent of the GSA LCO.

C. For purposes of price evaluation, the Commission Credit shall be treated as a deduction from the rent in accordance with the Method of Award. The amount of any commission paid to the Broker shall not be considered separately as part of this price evaluation since the value of the commission is included in the rental consideration.

1.15 NORTH AMERICAN INDUSTRY CLASSIFICATION SYSTEM (NAICS) CODE AND SMALL BUSINESS SIZE

STANDARD (OCT 2019)

A. The North American Industry Classification System (NAICS) code for this acquisition is 531120, unless the real property is self-storage (#531130), land (#531190), or residential (#531110).

B. The small business size standard is $41.5 Million in annual average gross revenue of the concern for the last 3 fiscal years.

C. The small business size standard for a concern which submits an offer in its own name, other than on a construction or service contract, but which proposes to furnish a product which it did not itself manufacture, is 500 employees.

1.16 DUNS NUMBER (OCT 2017)

An offeror may obtain a DUNS number (i) via the Internet at http://fedgov.dnb.com/webform or if the offeror does not have internet access, it may call Dun and Bradstreet at 1-866-705-5711 if located within the United States; or (ii) If located outside the United States, by contacting the local Dun and Bradstreet office. The offeror should indicate that it is an offeror for a U.S. Government contract when contacting the local Dun and Bradstreet office.

http://fedgov.dnb.com/webform

RLP NO. 8MD2389, PAGE 6 GSA FORM R100 (02/20)

SECTION 2 ELIGIBILITY AND PREFERENCES FOR AWARD

2.01 EFFICIENCY OF LAYOUT (AUG 2011)

A. In order to be acceptable for award, the offered Space must provide for an efficient layout as determined by the LCO.

B. To demonstrate potential for efficient layout, GSA may request the Offeror to provide a test fit layout at the Offeror’s expense.

The Government will advise the Offeror if the test fit layout demonstrates that the Government's requirement cannot be accommodated within the Space offered. The Offeror will have the option of increasing the ABOA square footage offered, if it does not exceed the maximum ABOA square footage in this RLP offer package. If the Offeror is already providing the maximum ABOA square footage and cannot house the Government's space requirements efficiently, then the Government will advise the Offeror that the offer is unacceptable.

2.02 FLOOD PLAINS (OCT 2017)

A Lease will not be awarded for any offered Property located within a 100-year floodplain unless the Government has determined that there is no practicable alternative. An Offeror may offer less than its entire site in order to exclude a portion of the site that falls within a floodplain, so long as the portion offered meets all the requirements of this RLP and does not impact the Government’s full use and enjoyment of the Premises. If an Offeror intends that the offered Property that will become the Premises for purposes of this Lease will be something other than the entire site as recorded in tax or other property records the Offeror shall clearly demarcate the offered Property on its site plan/map submissions and shall propose an adjustment to property taxes on an appropriate pro rata basis. For such an offer, the LCO may, in his or her sole discretion, determine that the offered Property does not adequately avoid development in a 100-year floodplain.

In addition, a Lease will not be awarded for any offered Property adjacent to 100-year floodplain, where such an adjacency would, as determined by the LCO, in his or her sole discretion, restrict ingress or egress to the Premises in the event of a flood, unless there is no practicable alternative.

2.03 SEISMIC SAFETY – MODERATE SEISMICITY (OCT 2017) INTENTIONALLY DELETED

2.04 SEISMIC SAFETY – HIGH SEISMICITY (OCT 2017) INTENTIONALLY DELETED

2.05 HISTORIC PREFERENCE (SEP 2013)

A. The Government will give preference to offers of Space in Historic Properties and/or Historic Districts following this hierarchy of consideration:

1. Historic Properties within Historic Districts.

2. Non-historic developed sites and non-historic undeveloped sites within Historic Districts.

3. Historic Properties outside of Historic Districts.

B. Definitions:

1. Determination of eligibility means a decision by the Department of the Interior that a district, site, Building, structure or object meets the National Register criteria for evaluation although the Property is not formally listed in the National Register (36 CFR 60.3(c)).

2. Historic District means a geographically definable area, urban or rural, possessing a significant concentration, linkage, or continuity of sites, Buildings, structures, or objects united by past events or aesthetically by plan or physical development. A district may also comprise individual elements separated geographically but linked by association or history (36 CFR 60.3(d)). The Historic District must be included in or be determined eligible for inclusion in the National Register of Historic Places (NRHP).

3. Historic Property means any prehistoric or Historic District, site, building, structure, or object included in or been determined eligible for inclusion in the NRHP maintained by the Secretary of the Interior (36 CFR 800.16(l)).

4. National Register of Historic Places means the National Register of districts, sites, buildings, structures and objects significant in American history, architecture, archeology, engineering and culture that the Secretary of the Interior is authorized to expand and maintain under the National Historic Preservation Act (36 CFR 60.1).

C. The offer of Space must meet the terms and conditions of this RLP package and its attachments. The LCO has discretion to accept alternatives to certain architectural characteristics and safety features defined elsewhere in this RLP package to maintain the historical integrity of an Historic Building, such as high ceilings and wooden floors, or to maintain the integrity of an Historic District, such as setbacks, floor-to-ceiling heights, and location and appearance of parking.

RLP NO. 8MD2389, PAGE 7 GSA FORM R100 (02/20)

D. When award will be based on the lowest price technically acceptable source selection process, the Government will give a price evaluation preference, based on the total annual ABOA SF present value cost to the Government, to Historic Properties as follows:

1. First to suitable Historic Properties within Historic Districts, a 10 percent price preference.

2. If no suitable Historic Property within an Historic District is offered, or the 10 percent preference does not result in such property being the lowest price technically acceptable offer, the Government will give a 2.5 percent price preference to suitable non-historic developed or undeveloped sites within Historic Districts.

3. If no suitable, non-historic, developed, or undeveloped site within a Historic District is offered, or the 2.5 percent preference does not result in such property being the lowest price technically acceptable offer, the Government will give a 10 percent price preference to suitable Historic Properties outside of Historic Districts.

4. Finally, if no suitable Historic Property outside of Historic Districts is offered, no historic price preference will be given to any property offered.

E. When award will be based on the best value tradeoff source selection process, which permits tradeoffs among price and non-price factors, the Government will give a price evaluation preference, based on the total annual ABOA SF present value cost to the Government, to Historic Properties as follows:

1. First, to suitable Historic Properties within Historic Districts, a 10 percent price preference.

2. If no suitable Historic Property within a Historic District is offered or remains in the competition, the Government will give a 2.5 percent price preference to suitable non-historic developed or undeveloped sites within Historic Districts.

3. If no suitable, non-historic developed or undeveloped site within an Historic District is offered or remains in the competition, the Government will give a 10 percent price preference to suitable Historic Properties outside of Historic Districts.

4. Finally, if no suitable Historic Property outside of Historic Districts is offered, no historic price preference will be given to any property offered.

F. The Government will compute price evaluation preferences by reducing the price(s) of the Offerors qualifying for a price evaluation preference by the applicable percentage provided in this provision. The price evaluation preference will be used for price evaluation purposes only. The Government will award a Lease for the actual prices proposed by the successful Offeror and accepted by the Government.

G. To qualify for a price evaluation preference, Offeror must provide satisfactory documentation in their offer that their property qualifies as one of the following:

1. A Historic Property within a Historic District.

2. A non-historic developed or undeveloped site within a Historic District.

3. A Historic Property outside of a Historic District.

2.06 ASBESTOS (JUN 2012)

A. Government requests space with no asbestos-containing materials (ACM), or with ACM in a stable, solid matrix (e.g., asbestos flooring or asbestos cement panels), which is not damaged or subject to damage by routine operations. For purposes of this paragraph, “space” includes the 1) space offered for lease; 2) common building area; 3) ventilation systems and zones serving the space offered; and 4) the area above suspended ceilings and engineering space in the same ventilation zone as the space offered.

If no offers are received for such space, the Government may consider space with thermal system insulation ACM (e.g., wrapped pipe or boiler lagging), which is not damaged or subject to damage by routine operations.

B. ACM is defined as any materials with a concentration of greater than 1 percent by dry weight of asbestos.

C. Space with ACM of any type or condition may be upgraded by the Offeror to meet conditions described in sub-paragraph A by abatement (removal, enclosure, encapsulation, or repair) of ACM not meeting those conditions. If any offer involving abatement of ACM is accepted by the Government, the successful Offeror will be required to successfully complete the abatement in accordance with OSHA, EPA, Department of Transportation (DOT), state, and local regulations and guidance prior to occupancy.

D. Management Plan. If space is offered which contains ACM, the Offeror shall submit an asbestos-related management plan for acceptance by the Government prior to lease award. This plan shall conform to EPA guidance.

2.07 ACCESSIBILITY (SEP 2013)

The Lease contemplated by this RLP contains requirements for Accessibility. In order to be eligible for award, Offeror must either:

RLP NO. 8MD2389, PAGE 8 GSA FORM R100 (02/20)

A. Verify in the Lease proposal that the Building, offered Space, and areas serving the offered Space meet the Lease accessibility requirements, or

B. Include as a specific obligation in its Lease proposal that improvements to bring the Building, offered Space, and areas serving the offered Space into compliance with Lease accessibility requirements will be completed prior to acceptance of the Space.

2.08 FIRE PROTECTION AND LIFE SAFETY (SEP 2013)

The Lease contemplated by this RLP contains Building requirements for Means of Egress, Automatic Fire Sprinkler System, and Fire Alarm System. In order to be eligible for award, Offeror must either:

A. Verify in the Lease proposal that the Building in which Space is offered meets the Means of Egress, Automatic Fire Sprinkler System, and Fire Alarm System requirements of the Lease; or

B. Include as a specific obligation in its Lease proposal that improvements to bring the Building into compliance with Lease requirements will be completed prior to acceptance of the Space.

2.09 ENERGY INDEPENDENCE AND SECURITY ACT (OCT 2016)

A. The Energy Independence and Security Act (EISA) establishes requirements for Government leases relating to energy efficiency standards and potential cost effective energy efficiency and conservation improvements.

B. Unless one of the statutory exceptions listed in sub-paragraph C below applies, GSA may award a lease for a Building only if the Building has earned the ENERGY STAR® label conferred by the U.S. Environmental Protection Agency (EPA) within the most recent year prior to the due date for final proposal revisions. The term “most recent year” means that the date of award of the ENERGY STAR® label by EPA must not be more than 1 year prior to the due date of final proposal revisions. For example, an ENERGY STAR® label awarded by EPA on October 1, 2010, is valid for all lease procurements where final proposal revisions are due on or before September 30, 2011. In lieu of the above, all new Buildings being specifically constructed for the Government must achieve an ENERGY STAR® label within 18 months after occupancy by the Government. In addition, Offerors of the following Buildings shall also have up to 18 months after occupancy by the Government, or as soon thereafter as the Building is eligible for Energy Star® consideration, to achieve an Energy Star® label: 1) All existing Buildings that have had an Energy Star® label but are unable to obtain a label in the most recent year (i.e., within 12 months prior to the due date for final proposal revisions) because of insufficient occupancy; 2) Newly built Buildings that have used Energy® Star’s Target Finder tool and either achieved a “Designed to Earn the Energy Star®” certification or received an unofficial score (in strict adherence to Target Finder’s usage instructions, including the use of required energy modeling) of 75 or higher prior to the due date for final proposal revisions and who are unable to obtain a label in the most recent year because of insufficient occupancy; 3) An existing Building that is unable to obtain a label because of insufficient occupancy but that can produce an indication, through the use of energy modeling or past utility and occupancy data input into Energy Star’s® Portfolio Manager tool or Target Finder, that it can receive an unofficial score of 75 or higher using all other requirements of Target Finder or Portfolio Manager, except for actual data from the most recent year. ENERGY STAR® tools and resources can be found at HTTPS://WWW.ENERGYSTAR.GOV/.

C. EISA allows a Federal agency to lease Space in a Building that does not have an ENERGY STAR® Label if:

1. No Space is offered in a Building with an ENERGY STAR® Label that meets RLP requirements, including locational needs;

2. The agency will remain in a Building it currently occupies;

3. The Lease will be in a Building of historical, architectural, or cultural significance listed or eligible to be listed on the National Register of Historic Places; or

4. The Lease is for 10,000 RSF or less.

D. If one or more of the statutory exceptions applies, and the offered Space is not in a Building that has earned the ENERGY STAR® Label within one year prior to the due date for final proposal revisions, Offerors are required to include in their lease proposal an agreement to renovate the Building for all energy efficiency and conservation improvements that it has determined would be cost effective over the Firm Term of the Lease, if any, prior to acceptance of the Space (or not later than one year after the Lease Award Date of a succeeding or superseding lease). Such improvements may consist of, but are not limited to, the following:

1. Heating, Ventilating, and Air Conditioning (HVAC) upgrades, including boilers, chillers, and Building Automation System (BAS)/Monitoring/Control System (EMCS).

2. Lighting Improvements.

3. Building Envelope Modifications.

NOTE: Additional information can be found on http://www.gsa.gov/leasing under “Green Leasing.”

https://www.energystar.gov/

RLP NO. 8MD2389, PAGE 9 GSA FORM R100 (02/20)

E. The term "cost effective" means an improvement that will result in substantial operational cost savings to the landlord by reducing electricity or fossil fuel consumption, water, or other utility costs. The term "operational cost savings" means a reduction in operational costs to the landlord through the application of Building improvements that achieve cost savings over the Firm Term of the Lease sufficient to pay the incremental additional costs of making the Building improvements.

F. Instructions for obtaining an ENERGY STAR® Label are provided at http://www.energystar.gov/buildings/facility-owners-and-managers/existing-buildings/earn-recognition/energy-star-certification (use “Portfolio Manager” to apply). ENERGY STAR® tools and resources can be found at HTTPS://WWW.ENERGYSTAR.GOV/. The ENERGY STAR® Building Upgrade Manual (http://www.energystar.gov/buildings/facility-owners-and-managers/existing-buildings/save-energy/comprehensive-approach/energy-star) and Building Upgrade Value Calculator (http://www.energystar.gov/buildings/tools-and-resources/building-upgrade-value-calculator) are tools which can be useful in considering energy efficiency and conservation improvements to Buildings.

G. If one or more of the statutory exceptions applies, and the offered Space is not in a Building that has earned the ENERGY STAR® Label within one year prior to the due date for final proposal revisions, the successful Offeror will be excused from performing any agreed-to energy efficiency and conservation renovations, and benchmarking with public disclosure (as provided in (I) below, if it obtains the ENERGY STAR® Label prior to the Government’s acceptance of the Space (or not later than one year after the Lease Award Date for succeeding and superseding leases).

H. If no improvements are proposed, the Offeror must demonstrate to the Government using the ENERGY STAR® Online Tools why no energy efficiency and conservation improvements are cost effective. If such explanation is unreasonable, the offer may be rejected.

I. As described in Section 3 of the Lease, successful Offerors meeting one of the statutory exceptions above must agree to benchmark and publicly disclose the Building’s current ENERGY STAR® score, using EPA’s Portfolio Manager online software application. See the Lease for additional details.

J. All new Buildings being specifically constructed for the Government must achieve the ENERGY STAR® Label within 18 months after occupancy by the Government.

K. INTENTIONALLY DELETED

2.10 ENVIRONMENTAL CONSIDERATIONS (SEP 2013)

A. The Government requests space with no known hazardous conditions or recognized environmental conditions that would pose a health and safety risk or environmental liability to the Government.

B. Upon request by the Government, Offeror must provide all known previous use of the Building.

C. Offeror must indicate in its written offer any known hazardous conditions or environmental releases with/from the offered Space, Building or Property.

2.11 DUE DILIGENCE AND NATIONAL ENVIRONMENTAL POLICY ACT REQUIREMENTS - RLP (SEP 2014)

A. Environmental Due Diligence

1. At the direction of the LCO, the Offeror must provide, at the Offeror’s sole cost and expense, a current Phase I Environmental Site Assessment (ESA), using the American Society for Testing and Materials (ASTM) Standard E1527-13 and timeline, as such standard may be revised from time to time. In accordance with ASTM standards, the study must be performed by an environmental professional with qualifications that meet ASTM standards. This Phase I ESA must be prepared with a focus on the Government being the “user” of the Phase I, as the term “user” is defined in E1527-13. Failure to submit the required study may result in dismissal from consideration.

2. If the Phase I ESA identifies any recognized environmental conditions (RECs), the Offeror will be responsible for addressing such RECs, at its sole cost and expense, including performing any necessary Phase II ESA (using ASTM Standard E1903-11), performing any necessary cleanup actions in accordance with federal and state standards and requirements and submitting a proposed schedule for complying with these obligations. The Government will evaluate whether the nature of any of the RECs, the results of the Phase II, any completed cleanup, and the proposed schedule meet the Government’s needs.

B. National Environmental Policy Act

1. While the Offeror is responsible for performing all environmental due diligence studies of the offered Property, the Government is responsible for compliance with NEPA, whether in whole or in part, on its own or with the assistance of the Offerors.

NEPA requires federal agencies to consider the effects of their actions on the quality of the human environment as part of the federal decision making process and, to that end, the Government’s obligations may, and in some cases will, be augmented by the Offerors as described in greater detail in the RLP.

2. The Government may either request information from the Offerors to help it meet its obligations under NEPA or share information provided in response to this provision with federal, state and local regulatory agencies as part of its compliance responsibilities under NEPA and other applicable federal, state and local environmental laws and regulations. Further consultation with these regulatory agencies may be necessary as part of the NEPA process.

RLP NO. 8MD2389, PAGE 10 GSA FORM R100 (02/20)

3. The Offerors are advised that the Government may be required to release the location of each offered site and other building specific information in public hearings or in public NEPA documents. By submitting an offer in response to this RLP and without the need for any further documentation, the Offeror acknowledges and consents to such release.

4. The Government reserves the right to reject any offer where (i) the NEPA-related documentation provided by the Offeror for the offered Property is inadequate, (ii) the offer entails unacceptably adverse impacts on the human environment, (iii) the identified adverse impacts cannot be readily mitigated, or (iv) the level of NEPA analysis is more extensive than is acceptable to the Government (e.g., offers must be of a nature that would allow NEPA to be satisfied by preparation of a Categorical Exclusion (CATEX) NEPA study or an Environmental Assessment (EA) with or without mandatory mitigation).

5. An Offeror must allow the Government access to the offered Property to conduct studies in furtherance of NEPA compliance.

This requires research and field surveys to assess the potential impacts to the natural, social and cultural environments. Any recent studies previously conducted by the Offeror may be submitted to be included in the NEPA process.

6. The Government will not proceed with Lease award until the NEPA process is complete as evidenced by the Government’s issuance of a completed CATEX, EA or Environmental Impact Statement. Upon Lease award, any mitigation measures, whether optional or mandatory, identified and adopted by the Government will become Lease obligations. All costs and expenses for development of design alternatives, mitigation measures and review submittals for work to be performed under the Lease will be the sole responsibility of Lessor.

2.12 NATIONAL HISTORIC PRESERVATION ACT REQUIREMENTS - RLP (OCT 2016)

A. The Government is responsible for complying with section 106 of the National Historic Preservation Act of 1966, as amended, 54 U.S.C. § 306108 (Section 106). Section 106 requires federal agencies to consider the effects of their actions on historic properties prior to expending any federal funds on the undertaking. The Government is responsible for identifying whether any historic properties exist in, on, under, or near the offered Property that could be affected by the leasing action. Historic properties include both above-grade (i.e., buildings and historic districts) and below-grade (i.e., archeological sites) resources. The Government is responsible for assessing effects to identified historic properties and for consulting with the State Historic Preservation Officer (SHPO), the Tribal Historic Preservation Officer (THPO), if applicable, any local Historic Preservation or Landmarks Commission, and other interested parties, if applicable, in accordance with the implementing regulations set forth at 36 C.F.R. part 800 (Protection of Historic Properties).

B. An Offeror must allow the Government access to the offered Property to conduct studies in furtherance of the Section 106 compliance. This requires research and field surveys to assess the potential presence of historic properties that may be affected by construction activity, both above- and below-grade.

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .