GENERAL FIRE SAFETY REQUIREMENTS.pdf

PDF 102 KB Posted

Attached to
R1 Custer Gallatin National Forest/Sioux Ranger District Road Maintenance
Solicitation number
12363N24Q4187
Issued by

About this file

This document outlines the General Fire Safety Requirements for a federal contract opportunity related to road maintenance for the Custer Gallatin National Forest - Sioux Ranger District. The key requirements include:

  • Contractors must have fully charged and operable fire extinguishers and firefighting tools, such as shovels and Pulaskis, readily available on vehicles and equipment.
  • All internal combustion engines must have approved and properly maintained spark-arresting systems.
  • Restrictions may be imposed during "Hoot Owl" periods, which could curtail or shut down high-risk fire operations.

The related federal contract opportunity is a solicitation for road maintenance services on the Custer Gallatin National Forest in Montana and South Dakota. The estimated performance period is July 1, 2024 through November 30, 2024. This solicitation is a 100% small business set-aside. Interested parties should submit inquiries and responses to Contracting Officer Sonya Jones at sonya.jones@usda.gov.

View the file

Other files

File Type Posted
Amendment 0002.pdf PDF
Amendment 0001.pdf PDF
Maintenance East.pdf PDF
Maintenance West.pdf PDF
Specifications.pdf PDF
SF1449 12363N24Q4187.pdf PDF
Slim Buttes.pdf PDF
Sioux District.pdf PDF
Road Maintenance Plans.pdf PDF
Wage Determinations 1976-1342.pdf PDF
Chalk Buttes Ekalaka Hills Long Pines.pdf PDF
Wage Determinations 1979-1157.pdf PDF
Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

GENERAL FIRE SAFETY REQUIREMENTS

Fire Extinguishers and Firefighting tools

Chainsaw operators shall carry a fully charged and operable fire extinguisher, minimum-capacity 8-ounce liquid or 1-pound dry chemical with a 4BC or higher rating.

Vehicles and equipment mobile or stationary, with a combustion engine/motor used for

Contractor’s Operations must have one operable, dry-chemical fire extinguisher with a minimum 2.5 pound capacity and 4BC or higher rating.

Contractors’ Operations must have:

One serviceable shovel or Pulaski with each vehicle and equipment with an internal combustion engine/motor, mobile or stationary.

Other types of firefighting tools that provide increased efficiency or effectiveness may be substituted by written authorization. For example, a combi firefighting tool may be substituted for a shovel or pulaski.

Extinguisher and shovel shall be mounted as to be readily available.

Tool Specifications

Bucket: Metal, plastic, canvas, or fiberglass container capable of holding at least one gallon of water.

Combi Tool: A tool combining a shovel and pick.

Pulaski: An ax with a medium size sharp grub hoe opposite the ax blade.

Shovel: Vehicle, equipment, and chainsaw operator shovels will have a minimum overall length of 36 inches with a round pointed shovel head with a minimum width of 6 inches.

Shovels required for campfires must be at least 24-inces in length with a pointed shovel head. Folding handles quality.

Spark Arresters: All internal combustion engines must be equipped with an approved and effective spark-arresting system, as established in the National Wildfire Coordinating Group’s Spark Arrester Guides. Spark-arresting devices must be marked, properly installed, and maintained in accordance with the Guides.

The following vehicles are exempt:

a. Automobiles and light trucks of less than 23,000 GVW when all exhaust gases pass through a properly installed and maintained exhaust system, baffle-type muffler, and tailpipe. Vehicles with glass-pack mufflers do not qualify for the exemption.

b. Heavy-duty trucks of 23,000 GVW or greater, with a muffler and vertical stack exhaust system extending above the cab.

c. Vehicles with other spark-arresting systems providing equal or increased effectiveness. Such vehicles must be inspected and have written authorization from the recognized fire protection agency.

When Hoot Owl restrictions are invoked, the Forest Service may curtail or shut down all or portions of a Contactor’s operations. The following requirements may be imposed:

All high risk fire operations could be terminated at 1300 local time.