GCC-F 260-B1260-066 M21GC121 Project Drawings 2023-09-06.pdf
PDF 5 MB Posted
- Solicitation number
- 62431
- Issued by
- Spotsylvania County, Fredericksburg City, Virginia
About this file
This document is a invitation for sealed bids for the repair of the Curtain Wall on the Science & Engineering Building at Germanna Community College's Fredericksburg Campus, Project Code # 260-B1260-066 (M12GC121). The project generally consists of curtain wall repairs including new exterior gaskets, new joint stops, wet sealing of inside corners, and repairing interior gaskets. The scope also includes the replacement of existing spandrel glass. Bids will be received electronically through eVA or by mail until 3:00 PM on Tuesday, April 30, 2024. A pre-bid conference will be held on April 4, 2024 at the project site. The contract will be awarded after bid opening on May 1, 2024.
The bidder must be a registered vendor in eVA. A standard Commonwealth Bid Bond (CO-10.2) and Contract Security are required. Pricing terms, funding sources, and set-asides were not provided. There was no mention of an incumbent contractor or the current contract environment.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SHEET WHERE DETAIL IS FOUND
SECTION NUMBER
SHEET WHERE SECTION IS FOUND
SHEET WHERE ELEVATION IS FOUND
ELEVATION NUMBER
DETAIL NUMBER
VICINITY MAP
NOT TO SCALE
SITE MAP
NOT TO SCALE
SITE SITE
SYMBOLS
PROJECT NOTES
LIST OF DRAWINGS
SHEET NUMBER SHEET TITLE
G0.01 TITLE SHEET
G0.02 GENERAL NOTES
AS1.01 SITE PLAN
AS1.02 PARTIAL SITE PLAN - NORTH ENTRANCE
AS1.03 PARTIAL SITE PLAN - SOUTH ENTRANCE
AS1.04 PHASING PLAN
AS1.05 OVERHEAD PROTECTION DETAILS
A1.01 FIRST FLOOR PLAN - REPAIR
A1.02 SECOND FLOOR PLAN - REPAIR
A2.01 CURTAIN WALL ELEVATIONS
A2.02 CURTAIN WALL ELEVATIONS
A3.01 CURTAIN WALL SECTIONS
A3.02 CURTAIN WALL SECTIONS
A5.01 REPAIR DETAILS
A5.02 REPAIR DETAILS
PROJECT IDENTIFICATION
AGENCY: VIRGINIA COMMUNITY COLLEGE
PROJECT CODE NUMBER: 260-B1260-066 (M21GC121)
WDP PROJECT NUMBER: 21002
VIRGINIA COMMUNITY COLLEGE SYSTEM
GERMANNA COMMUNITY COLLEGE - FREDERICKSBURG AREA CAMPUS
10000 GERMANNA POINT DR., FREDERICKSBURG, VA 22408
SCIENCE BUILDING CURTAINWALL REPAIR
CODE ANALYSIS:
ORIGINAL CONSTRUCTION: 2012
ORIGINAL CODE: 2006 THE VIRGINIA UNIFORM STATE BUILDING CODE
REPAIR CONSTRUCTION:
CURRENT CODE: 2018 VIRGINIA CONSTRUCTION CODE AND VIRGINIA EXISTING BUILDING CODE
(VEBC)
OCCUPANCY GROUP: OCCUPANCY - B
CONSTRUCTION TYPE: TYPE 2-B (PROTECTED)
DR
AF
T
CH
EC
K
DE
SI
GN
CH
EC
K
RE
VI
SI
ON
S
JOB NUMBER
DATE
SCALE
SHEET
Ga te w ay B ou le va rd
Su ite
M an as sa s, VA
-2
Of fic e:
.2
.9
To ll
Fr ee
: 8
.7
.0
Fa x:
.2
.9 w w w .w dp a.
co m
09/06/2023
09/06/2023
VC
CS
GE
RM
AN
NA
C
OM
MU
NI
TY
C
OL
LE
GE
0 G
ER
MA
NN
A
PO
IN
T
DR
IV
E, F
RE
DE
RI
CK
SB
UR
G, V
A
SC
IE
NC
E
BU
ILD
IN
G
CU
RT
AI
NW
AL
L R
EP
AI
R
TI
TL
E
SH
EE
T
VR GA
D
RA
F
GA
D
21002
NTS
G0.01
NORTH
SCOPE OF WORK:
REPAIRS TO THE CURTAIN WALL GENERALLY CONSISTING OF REMOVING EXISTING GLASS AND
COMPONENTS THAT ARE TO BE CLEANED AND REINSTALLED WITH NEW EXTERIOR GASKETS, NEW
JOINT STOPS, WET SEALING THE INSIDE CORNERS, AND REPAIRING INTERIOR GASKETS AS NEEDED.
ABBREVIATIONS
SYMBOL DESCRIPTION
Ø DIAMETER
BLDG. BUILDING
CMU CONCRETE MASONRY UNIT
C.J. CONTROL JOINT
℄ CENTERLINE
CONT CONTINUOUS
CONTLY CONTINUOUSLY
FRP FIBER REINFORCED POLYMER
FRT FIRE RESISTANT TREATED
FT FEET
GA. GAUGE
MAX. MAXIMUM
MFR MANUFACTURER
MFRS MANUFACTURER'S
MIN. MINIMUM
NIS NOT IN SCOPE
O.C. ON CENTER
O.D. OUTSIDE DIAMETER
OPP. OPPOSITE
PSF PER SQUARE FOOT
PSI PER SQUARE INCH
P.T. PRESSURE TREATED
RCP REFLECTED CEILING PLAN
R.O. ROUGH OPENING
SIM. SIMILAR
SP SOUTHERN PINE
S.S. STAINLESS STEEL
TYP. TYPICAL
U.N.O. UNLESS NOTED OTHERWISE
ASBESTOS DISCLOSURE:
NO ASBESTOS CONTAINING MATERIALS SHALL BE USED ON THIS PROJECT. AN ASBESTOS
INSPECTION WAS NOT PERFORMED BECAUSE ALL PORTIONS OF THE EXISTING BUILDING THAT MAY
BE AFFECTED BY THE WORK WERE ORIGINALLY CONSTRUCTED AFTER JANUARY 1, 1985.
LEAD DISCLOSURE:
AN INSPECTION TO IDENTIFY LEAD CONTAINING OR COATED BUILDING COMPONENTS HAS NOT BEEN CONDUCTED BECAUSE THE BUILDING WAS CONSTRUCTED AFTER JANUARY 1, 1985 AND THE OWNER HAS NO KNOWLEDGE OF LEAD CONTAINING OR COATED BUILDING COMPONENTS IN THE BUILDING. IT IS THE CONTRACTOR’S RESPONSIBILITY TO COMPLY WITH ALL VIRGINIA OCCUPATIONAL SAFETY AND HEALTH (VOSH) REGULATIONS AS THEY PERTAIN TO EMPLOYEE EXPOSURES TO LEAD. ALL LEAD AND
LEAD-COATED BUILDING COMPONENTS SHALL BE RECYCLED TO THE EXTENT POSSIBLE.
ORIGINAL DRAWINGS FOR
INFORMATION ONLY
SHEET NUMBER SHEET TITLE
GI101 LIFE SAFETY PLANS
AE103 THIRD FLOOR AND LOWER ROOF PLAN
100% SET - ISSUE FOR BID
1. THE CONTRACTOR AND ANY SUB-CONTRACTORS SHALL ABIDE BY ALL LOCAL AND STATE REGULATIONS AND ALL OTHER APPLICABLE LAWS AND REGULATIONS OF THE COMMONWEALTH OF VIRGINIA, INCLUDING THOSE THAT MAY BE ISSUED DURING THE CONTRACT.
OWNER POLICIES PERTAINING TO SEXUAL HARASSMENT, DRUG AND ALCOHOL USE, ABUSIVE AND OFFENSIVE LANGUAGE, AND SMOKING
SHALL BE ADHERED TO.
2. CONTRACTOR SHALL BE FAMILIAR WITH AND ABIDE BY ALL REQUIREMENTS OF THE GENERAL CONDITIONS OF THE CONSTRUCTION
CONTRACT (DGS FORM CO-7).
3. PRIOR TO START OF CONSTRUCTION, CONTRACTOR SHALL OBTAIN ANY REQUIRED BUILDING PERMITS, OR ANY OTHER PERMITS REQUIRED BY STATE OR LOCAL JURISDICTIONS. SUBMIT COPIES OF THE PERMITS TO THE OWNER AND A/E.
4. ALL PERSONNEL SHALL BE IDENTIFIED WITH VISIBLE COMPANY IDENTIFICATION ON OUTER GARMENTS.
5. NO PHOTOGRAPHY OF ANY PERSONS ON THE PROPERTY UNLESS SPECIFIC PERMISSION IS OBTAINED IN ADVANCE.
6. CONTRACTOR IS SOLELY RESPONSIBLE FOR JOBSITE SAFETY THAT COMPLIES WITH ALL APPLICABLE OSHA, STATE, AND LOCAL SAFETY
GUIDELINES. ADDITIONALLY, CONTRACTOR SHALL PROVIDE ADEQUATE PROTECTION FOR THE EXISTING BUILDING AND OCCUPANTS IN ACCORDANCE WITH OSHA AND ALL APPLICABLE STATE AND LOCAL CODES AND REGULATIONS CONTRACTOR SHALL DEVELOP A PROJECT SPECIFIC SITE SAFETY PLAN TO COMPLY WITH ALL OWNER, LOCAL, STATE, AND FEDERAL REQUIREMENTS.
7. WORK SHALL BE PERFORMED DURING NORMAL BUSINESS HOURS MONDAY THROUGH FRIDAY FROM 7 AM TO 3:30 PM OR AS APPROVED BY THE OWNER. WEEKEND WORK AND WORK STARTING BEFORE 7 AM OR AFTER 5 PM DURING THE NORMAL WORK WEEK SHALL BE COORDINATED AND APPROVED BY THE OWNER AT LEAST 48 HOURS PRIOR TO THE START OF WORK.
8. PRIOR TO START OF CONSTRUCTION, A/E SHALL SCHEDULE A PRECONSTRUCTION MEETING ON-SITE TO REVIEW THE DRAWINGS, DETAILS, PROJECT SCHEDULE, SUBMITTAL APPROVALS, REQUIRED TESTS AND REPORTS, AND ANY QUESTIONS PRIOR TO THE START OF WORK. AT A MINIMUM THE CONTRACTOR'S PROJECT MANAGER, OWNER'S REPRESENTATIVE, AND A/E'S PROJECT MANAGER SHALL BE IN
ATTENDANCE. SEE DIVISION 01 (01 31 00).
9. CONTRACTOR SHALL SEND SEQUENTIALLY NUMBERED RFI FORMS TO REQUEST CLARIFICATIONS.
10. CONTRACTOR SHALL ALLOT A MINIMUM 7-CALENDAR DAYS FOR RFI RESPONSES FROM THE A/E. CONTRACTOR SHALL IMMEDIATELY
REPORT ANY DISCREPANCIES BETWEEN THE INFORMATION ON THESE DRAWINGS AND THE CONDITIONS IN THE FIELD TO THE A/E VIA RFI.
SEE DIVISION 01 (01 00 00).CONTRACTOR SHALL STAMP AND PROPERLY NUMBER EACH REQUIRED SUBMITTAL ITEM, SENT WITH A TRANSMITTAL COVER TO THE A/E FOR REVIEW. CONTRACTOR SHALL ALLOT A MINIMUM 14-CALENDAR DAYS FOR SUBMITTAL REVIEWS FROM THE A/E. CONTRACTOR MAY SUBMIT ALTERNATIVES WITH JUSTIFICATION AND NO ADDITIONAL COST TO THE OWNER.
ALTERNATIVES MUST BE EQUIVALENT OR BETTER AND BE SUBMITTED FOR APPROVAL BY THE A/E AND OWNER PRIOR TO THE BEGINNING
OF THAT WORK. SEE DIVISION 01 AND TECHNICAL SECTIONS FOR SPECIFIC REQUIREMENTS.
11. CONTRACTOR SHALL SCHEDULE PROGRESS MEETINGS THROUGHOUT THE WORK, NO LESS THAN TWO PER MONTH. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DEVELOPING MEETING AGENDA AND SHALL RECORD AND DISTRIBUTE MEETING MINUTES. AT A MINIMUM, THE AGENDA FOR EACH MEETING SHALL COVER THE FOLLOWING: SCHEDULE, ISSUES, RFI'S, REQUEST FOR PROPOSALS, ESTIMATED CHANGE ORDERS, SUBMITTALS AND SUBMITTAL STATUS, SAFETY, SECURITY, CONDUCT, AND OWNER COORDINATION. SEE DIVISION 01 (01 31 00).
12. AT THE CONCLUSION OF THE PROJECT, SUBMIT AS-BUILT MARKUP DOCUMENTS. SEE DIVISION 01 (01 78 39).
GENERAL REQUIREMENTS GENERAL NOTES
1. SEE WDP REPORT OF PREVIOUSLY COMPLETED PROTOTYPE CURTAIN WALL REPAIRS THAT OUTLINES THE SCOPE, NOTES EXISTING CONDITIONS OF THE CURTAIN WALL SYSTEM OBSERVED AFTER GLASS WAS REMOVED, AND PROVIDES THE RESULTS OF AAMA 501.2
WATER TESTING AFTER PROTOTYPE REPAIRS WERE COMPLETED.
2. THE GENERAL SCOPE OF WORK IS REPAIRS TO THE EXISTING CURTAIN WALL AT THE 2-STORY LIBRARY PORTION OF THE BUILDING.
EXISTING INSULATED GLAZING UNITS (IGUS), SPANDREL GLASS, AND NOTED COMPONENTS TO BE REMOVED AND REINSTALLED. REPAIRS INCLUDE NEW EXTERIOR GASKETS, NEW JOINT STOPS, AND REPAIRING INTERIOR GASKETS AS NEEDED WITH WET SEALING AT THE INSIDE
CORNERS.
3. THE PROPERTY SHALL REMAIN OCCUPIED DURING EXECUTION OF THE WORK.
· ALL ENTRANCES SHALL REMAIN OPEN THROUGHOUT CONSTRUCTION, EXCEPT FOR THE NORTH STAIRWELL 1ST FLOOR EXTERIOR
DOOR DURING STAGE 1 AND SOUTH STAIRWELL 1ST FLOOR EXTERIOR DOOR DURING STAGE 8. WHEN REPAIRS ARE TAKING PLACE, SIGNAGE SHALL BE POSTED AND PORTION OF THE INTERIOR TEMPORARY BLOCKED DURING EACH STAGE. SAFE EGRESS INTO AND OUT OF THE SITE SHALL BE MAINTAINED AT ALL TIMES THROUGHOUT THE CONSTRUCTION. SEE DIVISION 01 AND SITE PLANS.
· THE CONTRACTOR SHALL FURNISH SIGNS, PROTECTION, BARRICADES, LIGHTS, AND WARNING DEVICES TO CONTROL THE ORDERLY FLOW OF PEDESTRIAN TRAFFIC AND PREVENT PEDESTRIANS FROM ENTERING AREAS OF THE CONTRACTOR'S OPERATIONS. WHERE POSSIBLE, HOSES, CONDUITS, ELECTRICAL CORDS, ETC., SHALL BE LOCATED OVERHEAD. WHENEVER SUCH ITEMS ARE LOCATED IN TRAFFIC PATHS, PREMANUFACTURED COVERINGS WITH ADEQUATE SIGNS SHALL BE FURNISHED. THE CONTRACTOR SHALL MOVE THESE SIGNS, BARRICADES, LIGHTS, AND WARNING DEVICES AS NECESSARY AS THE LOCATION OF WORK CHANGES.
· EXECUTE WORK AS QUIETLY AS PRACTICABLE TO AVOID UNNECESSARY DISTURBANCES TO OCCUPANTS WITHIN PREMISES.
HIGH-LEVEL NOISE OPERATIONS MUST BE PERFORMED IN ACCORDANCE WITH LOCAL REGULATIONS AND MUST BE APPROVED BY THE OWNER PRIOR TO PROCEEDING. LOUD NOISE AND VIBRATIONS MUST BE CONTROLLED AND COORDINATED IN ADVANCE WITH THE
OWNER. REQUEST PERMISSION IN WRITING AT LEAST THREE (3) DAYS IN ADVANCE.
4. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL CONDITIONS, MATERIALS, DIMENSIONS, AND LOCATIONS, IN THE FIELD. IF CONDITIONS VARY FROM WHAT IS PRESENTED IN THE DRAWINGS, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE A/E VIA RFI.
5. CONTRACTOR SHALL PERFORM A PRECONSTRUCTION WALK-THROUGH AND DOCUMENT EXISTING CONDITIONS OF THE BUILDING EXTERIOR GROUNDS AND LANDSCAPING. DOCUMENTATION SHALL BE IN THE FORM OF DIGITAL PHOTOGRAPHS KEYED TO BUILDING PLAN/SITE PLAN. DAMAGED CONDITIONS AT THE CONCLUSION OF THE PROJECT THAT HAVE NOT BEEN PREVIOUSLY DOCUMENTED WILL BE REPAIRED BY THE CONTRACTOR AT THEIR EXPENSE IN A MANNER THAT IS ACCEPTABLE TO THE OWNER. SEE DIVISION 01 (01 32 33).
6. ELEVATIONS SHOWN ARE BASED ON ORIGINAL CONSTRUCTION DRAWINGS AND LIMITED SITE INVESTIGATION. ELEVATIONS SHALL BE
USED AS RELATIVE REFERENCES. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS.
7. EXISTING DIMENSIONS OF ELEMENTS HAVE BEEN ASSUMED BASED ON ORIGINAL CONSTRUCTION DRAWINGS. EXISTING DIMENSIONS, SLOPES, AND DETAILS OF ARCHITECTURAL ELEMENTS AND FINISHES HAVE BEEN ASSUMED BASED ON ORIGINAL CONSTRUCTION DRAWINGS AND LIMITED SITE INVESTIGATION. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS.
8. ALL DETAIL CALL-OUTS ARE TYPICAL FOR AREAS OF SIMILAR CONSTRUCTION AND REPRESENT WORK TO BE PERFORMED AT SIMILAR
CONDITIONS, UNLESS NOTED OTHERWISE.
9. ALL DETAILS ARE GENERIC AND MAY VARY BASED ON SPECIFIC MANUFACTURER'S REQUIREMENTS, RECOMMENDATIONS, AND INSTALLATION INSTRUCTIONS. IN CASES OF DISCREPANCY BETWEEN DETAILS HEREIN AND MANUFACTURER'S WRITTEN REQUIREMENTS, THE MOST STRINGENT REQUIREMENTS SHALL PREVAIL.
10. SYMBOLS IN THE DRAWINGS ARE NOT TO SCALE. DO NOT SCALE DRAWINGS FOR QUANTITIES.
11. THE CONTRACTOR SHALL INSTALL ALL PROTECTION REQUIRED TO COMPLY WITH OSHA CFR 1926.1153, THE CONTRACT DOCUMENTS, STATE, FEDERAL, AND LOCAL JURISDICTIONS AND TO PROTECT WORKMEN, THE PUBLIC, AND ADJACENT AREAS FROM RESPIRABLE CRYSTALLINE SILICA GENERATED BY DRILLING OR CUTTING MASONRY, AND ANY OTHER SILICA CONTAINING PRODUCTS ON SITE.
12. CONSTRUCTION FENCE SHALL BE PROVIDED AS INDICATED ON THE SITE PLAN. SEE DIVISION 01 (01 50 00).
13. THE CONTRACTOR LAYDOWN AREA SHALL BE PROVIDED IN THE AREA AS SHOWN ON THE SITE PLANS AND ACCESS TO THE WORK AREA
SHALL BE FROM THE LAYDOWN AREA AS SHOWN. EQUIPMENT AND MATERIALS SHALL BE STORED IN LOCATIONS APPROVED BY THE OWNER AND SHALL NOT ENCUMBER THE PUBLIC, SURROUNDING RIGHTS OF WAY, OR ADJOINING GROUNDS. THE CONTRACTOR SHALL
COORDINATE WITH THE OWNER IF ADDITIONAL LAYDOWN AREA IS REQUIRED.
14. FURNISH SECURITY AND FACILITIES TO PROTECT WORK AND EXISTING PREMISES FROM UNAUTHORIZED ENTRY, VANDALISM, AND THEFT.
CONDUCT OPERATIONS IN A MANNER TO AVOID RISK OF LOSS, THEFT, OR DAMAGE BY VANDALISM.
15. FIRE PROTECTION - FURNISH AND MAINTAIN ADEQUATE FIRE PROTECTION IN THE FORM OF FIRE EXTINGUISHERS OR OTHER EFFECTIVE MEANS OF EXTINGUISHING FIRE, READY FOR INSTANT USE, DISTRIBUTED AROUND THE PROJECT. FURNISH TYPES, SIZES, NUMBERS AND LOCATIONS AS WOULD BE REASONABLY EFFECTIVE IN EXTINGUISHING FIRES DURING EARLY STAGES, BY PERSONNEL AT PROJECT SITE.
FURNISH TYPE A EXTINGUISHER AT LOCATIONS OF LOW POTENTIAL FOR EITHER ELECTRICAL OR GREASE-OIL FLAMMABLE LIQUID FIRES;
FURNISH TYPE ABC DRY CHEMICAL EXTINGUISHER AT OTHER LOCATIONS; COMPLY WITH RECOMMENDATIONS OF NFPA NO. 10.
16. CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL EXISTING MATERIALS TO REMAIN. DAMAGED MATERIALS TO REMAIN SHALL BE CLEANED, REPAIRED, OR REPLACED AT NO ADDITIONAL COST TO THE OWNER AND SHALL MATCH EXISTING.
17. CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTION OF EXISTING TREES, LANDSCAPING, AND PAVERS ADJACENT TO AND IN THE WORK SITE. TAKE CARE TO PREVENT DAMAGE TO ROOTS OF PLANTINGS TO REMAIN. REPLACE DAMAGED OR REMOVED PAVERS AND
PLANTINGS IN KIND ONCE FINAL GRADING IS COMPLETE. SEE DIVISION 01 (01 56 39)
18. EXISTING ELECTRICAL SERVICE WILL REMAIN ACTIVE. THE OWNER WILL FURNISH THE CONTRACTOR WITH ELECTRICITY FOR
CONSTRUCTION USE.
19. OWNER WILL FURNISH THE CONTRACTOR WITH EXISTING SOURCE(S) OF WATER FOR CONSTRUCTION USE.
20. CONTRACTOR SHALL FURNISH AND MAINTAIN TEMPORARY SANITARY FACILITIES AND ENCLOSURES, I.E. PORTA-JOHNS.
21. TEMPORARY MATERIALS MAY BE NEW OR USED IF USED MATERIALS HAVE NOT BEEN MODIFIED OR DAMAGED SUCH THAT THE INTEGRITY, DURABILITY, PERFORMANCE, OR CAPACITY OF THE MATERIAL HAS BEEN AFFECTED.
22. ALL WORK AREAS SHALL BE CLEANED DAILY.
23. CONTRACTOR SHALL KEEP EXISTING SITE AND BUILDING DRAINS CLEAN AND FREE OF DEBRIS DURING THE WORK. SNAKE DRAINS AS
REQUIRED TO MAINTAIN FUNCTIONALITY.
24. CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF ALL CONSTRUCTION WITH THE OWNER.
25. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DUST AND HVAC CONTROL MEASURES. SUBMIT A DUST AND HVAC CONTROL PLAN PRIOR
TO STARTING WORK TO BE APPROVED BY THE A/E AND OWNER. SEE DIVISION 01 (01 50 00).
26. THE BUILDING SHALL BE KEPT WATERTIGHT AT ALL TIMES DURING CONSTRUCTION. COST FOR TEMPORARY PROTECTION SHALL BE
CONSIDERED PART OF THE ACCEPTED BID PRICE. COST FOR DAMAGES RESULTING FROM THE CONTRACTOR'S WORK OR LACK OF
PROTECTION SHALL BE BORNE ENTIRELY BY THE CONTRACTOR.
27. CONTRACTOR SHALL ENSURE COMPATIBILITY OF ALL MATERIALS, AND SUBMIT INFORMATION VERIFYING COMPATIBILITY UPON REQUEST.
CONTRACTOR IS TO PROCEED ONLY AFTER GIVEN SUBMITTAL APPROVAL, NOT BEFORE.
28. STORE MATERIALS IN STRICT ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS AND KEEP ALL SEALS AND LABELS INTACT AND
LEGIBLE.
29. CONTRACTOR SHALL INSTALL ALL PRODUCTS PER THE MANUFACTURER'S WRITTEN INSTRUCTIONS AND THE CONTRACT DOCUMENTS. IN THE EVENT THAT JOB CONDITIONS OR SPECIFIED REQUIREMENTS CONFLICT WITH THE MANUFACTURER'S INSTRUCTIONS, SUBMIT AN RFI
TO THE A/E BEFORE PROCEEDING WITH THE WORK.
30. CONTRACTOR IS RESPONSIBLE FOR MEANS AND METHODS AND SHALL MAINTAIN THE INTEGRITY AND STABILITY OF THE EXISTING CURTAIN WALL SYSTEM AND ADJUST WALLS DURING DEMOLITION UNTIL THE WORK IS COMPLETED.
31. THE WORKMANSHIP SHALL BE WARRANTED BY THE CONTRACTOR FOR A PERIOD OF ONE (1) YEAR FROM FINAL ACCEPTANCE OF THE PROJECT. INDIVIDUAL PRODUCT SYSTEMS SHALL BE WARRANTED PER THE SPECIFICATIONS WITHIN THESE DRAWINGS. THE WARRANTY SHALL ASSIGN THE RIGHTS TO ALL MATERIALS AND MANUFACTURER'S WARRANTIES TO THE OWNER. THE WORK IS WARRANTED AGAINST DEFECTIVE MATERIALS AND WORKMANSHIP FOR THE WARRANTY PERIOD AND DURING THIS PERIOD SHALL BE REPLACED BY THE CONTRACTOR AT NO COST TO THE OWNER. THE WORK IS WARRANTED AGAINST WATER LEAKAGE INTO THE BUILDING OR ITS
ASSOCIATED COMPONENTS.
32. WHERE NEW WORK ABUTS OR ALIGNS WITH EXISTING, THE CONTRACTOR SHALL PERFORM A SMOOTH AND EVEN TRANSITION.
33. QUALITY CONTROL: SEE DIVISION 01 AND TECHNICAL SPECIFICATIONS SECTIONS FOR SPECIFIC REQUIREMENTS.
· MOCK UP: PERFORM TESTING OF A REQUIRED IN-PLACE MOCKUP TO ASSESS WORKMANSHIP AND PERFORMANCE OF THE IMPLEMENTED REPAIRS AT STAGE 1 OF THE PROJECT. A/E WILL ISSUE A REPORT OUTLINING PUNCH LIST ITEMS OBSERVED IN THE
MOCKUP INSTALLATION AND PERFORMANCE OF THE MOCKUP.
· FAILURE AND RE-TESTING: REGARDLESS OF THE ORIGINAL ASSIGNMENT OF RESPONSIBILITY FOR INSPECTION, TESTING, OR SIMILAR SERVICES, THE CONTRACTOR SHALL BE RESPONSIBLE FOR RE-ACCOMPLISHING WHERE RESULTS ARE UNSATISFACTORY AND NON-COMPLIANT WITH CONTRACT DOCUMENT REQUIREMENTS. REMOVAL AND REPLACEMENT WORK NECESSITATED BY SUCH NONCOMPLIANCE SHALL BE AT THE CONTRACTOR'S EXPENSE. WHEN INSPECTIONS, TESTS, OR SIMILAR SERVICES CANNOT BE PERFORMED AFTER PROPER NOTIFICATION AND AT THE FAULT OF THE CONTRACTOR, RESCHEDULE COSTS WILL BE THE
CONTRACTOR'S RESPONSIBILITY.
· COORDINATION: REGARDLESS OF THE ORIGINAL ASSIGNMENT OF RESPONSIBILITY FOR INSPECTION, TESTING, OR SIMILAR SERVICES, THE CONTRACTOR SHALL COORDINATE WITH EACH AGENCY ENGAGED AND SEQUENCE CONSTRUCTION ACTIVITIES TO ACCOMMODATE REQUIRED SERVICES WITH A MINIMUM OF DELAY. IN ADDITION, THE CONTRACTOR SHALL COORDINATE WITH EACH AGENCY'S ACTIVITIES TO AVOID THE NECESSITY OF REMOVING AND REPLACING CONSTRUCTION TO ACCOMMODATE. THE
CONTRACTOR IS RESPONSIBLE FOR
- SCHEDULING TIMES FOR INSPECTIONS, TESTS, TAKING SAMPLES AND SIMILAR ACTIVITIES;
- NOTIFYING THE A/E, OWNER'S INSPECTOR, 3RD/ PARTY INSPECTOR, AND TESTING AGENCY 48 HOURS IN ADVANCE OF OPERATIONS
REQUIRING TESTING SERVICES; AND
- PROVIDING INCIDENTAL LABOR, ACCESS, AND FACILITIES TO FACILITATE INSPECTIONS, TESTS, SAMPLE TAKING AND APPROPRIATE
SAMPLE STORAGE.
· PROTECTION AND REPAIR: REGARDLESS OF THE ORIGINAL ASSIGNMENT OF RESPONSIBILITY FOR INSPECTION, TESTING OR SIMILAR
SERVICES, REPAIR AND PROTECTION ARE THE CONTRACTOR'S RESPONSIBILITY. UPON COMPLETION OF INSPECTION, TESTING, SAMPLE-TAKING AND SIMILAR SERVICES, REPAIR DAMAGED CONSTRUCTION INCLUDING DEFICIENCIES IN VISUAL QUALITIES OF EXPOSED FINISHES. PROTECT CONSTRUCTION EXPOSED BY OR FOR QUALITY CONTROL SERVICE ACTIVITIES, AND PROTECT
REPAIRED CONSTRUCTION.
34. KEEP ALL STREETS, DRIVES, AND WALKS ADJACENT TO SITE AND HAUL ROUTES CLEAN AND FREE OF DIRT, DEBRIS, AND LITTER CAUSED BY CONSTRUCTION OPERATIONS. ANY DIRT, DEBRIS, AND LITTER CAUSED BY CONSTRUCTION OPERATIONS MUST BE REMOVED
IMMEDIATELY.
35. IF DIVISION 01 AND TECHNICAL SPECIFICATION SECTIONS ARE IN CONFLICT WITH THESE NOTES, COMPLY WITH THE MOST STRINGENT
REQUIREMENTS.
WIND LOADS:
BASIC WIND SPEED, V 120 mph
OCCUPANCY CATEGORY III
WIND EXPOSURE CATEGORY B
PER ASCE 7-10:
(AT 3RD FLOOR ROOF)
VELOCITY PRESSURE +15 PSF
FIELD ROOF PRESSURE -18 PSF
PERIMETER ROOF PRESSURE -30 PSF
CORNER ROOF PRESSURE -45 PSF
HORIZONTAL WALL PRESSURE -22 PSF
ANSI/SPRI/FM 4435/ES-1:
FOR RE-2 AND RE-3, CORNERS
P DESIGN, HORIZONTAL (ZONE 5) 44 PSF
FOR RE-2 AND RE-3, PERIMETERS
P DESIGN, HORIZONTAL (ZONE 4) 35 PSF
FOR RE-3, CORNERS
P DESIGN, VERTICAL (ZONE 3) 91 PSF
FOR RE-3, PERIMETERS
P DESIGN, VERTICAL (ZONE 2) 60 PSF
DR
AF
T
CH
EC
K
DE
SI
GN
CH
EC
K
RE
VI
SI
ON
S
JOB NUMBER
DATE
SCALE
SHEET
Ga te w ay B ou le va rd
Su ite
M an as sa s, VA
-2
Of fic e:
.2
.9
To ll
Fr ee
: 8
.7
.0
Fa x:
.2
.9 w w w .w dp a.
co m
09/06/2023
09/06/2023
VC
CS
GE
RM
AN
NA
C
OM
MU
NI
TY
C
OL
LE
GE
0 G
ER
MA
NN
A
PO
IN
T
DR
IV
E, F
RE
DE
RI
CK
SB
UR
G, V
A
SC
IE
NC
E
BU
ILD
IN
G
CU
RT
AI
NW
AL
L R
EP
AI
R
GE
NE
RA
L N
OT
ES
VR GA
D
RA
F
GA
D
21002
NTS
G0.02100% SET - ISSUE FOR BID
SCALE: 1
32"=1'-0"
AS1.01
SITE PLAN
PLAN NORTH
DR
AF
T
CH
EC
K
DE
SI
GN
CH
EC
K
RE
VI
SI
ON
S
JOB NUMBER
DATE
SCALE
SHEET
Ga te w ay B ou le va rd
Su ite
M an as sa s, VA
-2
Of fic e:
.2
.9
To ll
Fr ee
: 8
.7
.0
Fa x:
.2
.9 w w w .w dp a.
co m
09/06/2023
09/06/2023
VC
CS
GE
RM
AN
NA
C
OM
MU
NI
TY
C
OL
LE
GE
0 G
ER
MA
NN
A
PO
IN
T
DR
IV
E, F
RE
DE
RI
CK
SB
UR
G, V
A
SC
IE
NC
E
BU
ILD
IN
G
CU
RT
AI
NW
AL
L R
EP
AI
R
SI
TE
P
LA
N
VR GA
D
RA
F
GA
D
21002
NTS
AS1.01
SCIENCE BUILDING
WORKFORCE AND
TECHNOLOGY CENTER
V. EARL DICKINSON BUILDING
PARKING STRUCTURE
NOTES:
1. SITE PLAN IS CONCEPTUAL. CONTRACTOR
SHALL SUBMIT SITE LOGISTICS PLAN FOR
REVIEW BY THE ENGINEER OF RECORD,
GERMANNA COMMUNITY COLLEGE FACILITY
DEPT, AND CAMPUS POLICE.
2. PROTECT SITE AMENITIES, LANDSCAPING, AND
HARDSCAPES. DAMAGED ITEMS TO BE
REPLACED AT END OF PROJECT. PROTECT
TRAVEL PATH BETWEEN LAYDOWN AREA AND
WORK AREA.
3. SECURE LAYDOWN, ACCESS PATH AND WORK
AREA. RESTORE ALL AFTER PROJECT
COMPLETED.
4. CONTRACTOR WILL ONLY ACCESS THE WORK
AREA THROUGH THE LAYDOWN AREA AND
ACCESS PATH UNLESS GIVEN PRIOR APPROVAL
BY GERMANNA CC FOR TEMPORARY USE,
SUBMIT AT LEAST 1 WEEK PRIOR.
5. PROVIDE EROSION AND SEDIMENTATION
CONTROL MEASURES AT EXISTING SITE
DRAINAGE.
AS1.02
AS1.03
CONTRACTOR ACCESS PATH FROM LAYDOWN AREA TO
WORK AREA. AVOID TREE DRIP LINES AND TEMPORARILY
RELOCATE STONE BENCH AS NEEDED, TO BE REINSTALLED
IN ORIGINAL LOCATION AFTER PROJECT COMPLETION
±11 0'-0
'-1
0"
69'-0"
12'-10"
69'-0"
26'-1"
CONTRACTOR LAYDOWN AREA
'-0
115'-0"
UP
8' M
IN.
2x6 SP #2 PT., PAINTED
2x4 SP #2 PT., PAINTED
2"Ø GALVANIZED STEEL "U" CLAMP
4" PLYWOOD EXTERIOR GRADE
GALVANIZED STEEL POST, 31
2"Ø, TYP.
CONSTRUCTION FENCE CHAIN LINK
2x4 SP #2 PT., PAINTED
CHAIN LINK FENCING
GALVANIZED STEEL POST,
2"Ø, TYP.
4" PLYWOOD EXTERIOR GRADE
2"Ø STEEL "U" CLAMP
2x6 SP #2 PT., PAINTED
EQ
UA
L
EQ
UA
L
TOP RAIL 15
8"Ø, TYP.
SCREWS (2)#10x2" AT 8" O.C.
SCREWS (2)#10x2" AT 8" O.C.
BOTTOM RAIL, 15
8"Ø, TYP.
CANT STRIP, PAINTED, FINISH NAILS TO 2x4
BASE SUPPORT AS APPROPRIATE TO NOT
DISTURB OR DAMAGE EXISTING PAVERS
SCREWS #10x3" AT 6" O.C.
SCREWS #10x3" AT 6" O.C.
6" MA
X.
SCREWS (2)#10x2" AT 6" O.C.
PLYWOOD SEAM
2x6 SP #2, PAINTED
2"Ø POSTS AT
4' O.C. MAX.
GALVANIZED STEEL POST
2"Ø GALVANIZED STEEL "U" CLAMP,
NUTS AND WASHERS 2x6 SP #2 PT.
4" PLYWOOD EXTERIOR GRADE,
PAINTED BOTH FACES
CHAIN LINK FENCING
8" BOTTOM RAIL, TYP.
SCALE: 1
8"=1'-0"
AS1.02
PARTIAL SITE PLAN AND TEMPORARY
EGRESS - NORTH ENTRANCE
DR
AF
T
CH
EC
K
DE
SI
GN
CH
EC
K
RE
VI
SI
ON
S
JOB NUMBER
DATE
SCALE
SHEET
Ga te w ay B ou le va rd
Su ite
M an as sa s, VA
-2
Of fic e:
.2
.9
To ll
Fr ee
: 8
.7
.0
Fa x:
.2
.9 w w w .w dp a.
co m
09/06/2023
09/06/2023
VC
CS
GE
RM
AN
NA
C
OM
MU
NI
TY
C
OL
LE
GE
0 G
ER
MA
NN
A
PO
IN
T
DR
IV
E, F
RE
DE
RI
CK
SB
UR
G, V
A
SC
IE
NC
E
BU
ILD
IN
G
CU
RT
AI
NW
AL
L R
EP
AI
R
PA
RT
IA
L S
IT
E
PL
AN
NO
RT
H
EN
TR
AN
CE
VR GA
D
RA
F
GA
D
21002
NTS
AS1.02
NOTES:
1. SITE PLAN IS CONCEPTUAL. CONTRACTOR
SHALL SUBMIT SITE PLAN FOR REVIEW BY THE
ENGINEER OF RECORD, GERMANNA
COMMUNITY COLLEGE FACILITY DEPT, AND
CAMPUS POLICE.
2. PROTECT SITE AMENITIES, LANDSCAPING, AND
HARDSCAPES. DAMAGED ITEMS TO BE
REPLACED AT END OF PROJECT.
3. SEE AS1.04 FOR STAGING
4. RECORD DRAWING SHEET GI101, LIFE SAFETY
PLANS, ATTACHED AT END OF SET FOR
REFERENCE
LEGEND - SITE PLAN
CURTAIN WALL REPAIR
CONSTRUCTION FENCE
CONSTRUCTION FENCE DURING
STAGE 1 WORK ONLY
EXISTING SIDEWALK
OVERLAP OF SIDEWALK & CODE
RESTRICTED CONSTRUCTION AREA
ENTRY DOORS TO REMAIN OPEN
INSTALL OVERHEAD PROTECTION OR TEMPORARILY BLOCK
STAIR EXIT DOOR DURING WORK HOURS WHEN BARRIER
FENCE IS REQUIRED DUE TO ADJACENT WORK (STAGES 1
AND 9). UNBLOCK AND OPEN/REMOVE TEMPORARY FENCE
WHEN NOT WORKING TO ALLOW PEDESTRIAN USE. KEEP
AREA CLEAR WHEN NOT WORKING
EXTERIOR PEDESTRIAN WALKWAY IMPACTED
DURING STAGE 1 AND 9 CONSTRUCTION PER
CODE REQUIREMENTS FOR TEMPORARY
PROTECTION (SHADED AREA)
GROUP
STUDY 124
FIRE RATED DOOR: SECURE DOOR
OPEN FOR EGRESS WHEN STAIR
EXTERIOR EXIT IS BLOCKED
MA
TC
H
LIN
E
- S
EE
1/
AS
1.0
PLAN NORTH
CONTRACTOR ACCESS PATH FROM
LAYDOWN AREA TO WORK AREA
PROPOSED SITE ENCLOSURE
CONSTRUCTION FENCE
'-0
BARRIER FENCE NOTES:
1. BARRIER FENCE TO BE DESIGNED ACCORDING
TO CHAPTER 33 OF ICC. REFERENCE DIVISION
1 SPECIFICATIONS FOR ADDITIONAL
INFORMATION REGARDING TEMPORARY
PROTECTION
2. THE BARRIER FENCE SHALL BE A MINIMUM OF
8 FEET TALL ABOVE GRADE.
3. BARRIER FENCE, PLYWOOD, AND PLYWOOD
CONNECTIONS SHALL BE DESIGNED TO
RESIST A LATERAL UNIFORM SERVICE LOAD
OF 30 PSF APPLIED PERPENDICULAR TO THE
VERTICAL PLANE OF THE PLYWOOD BARRIER.
THE LATERAL LOAD SHALL BE ASSUMED TO BE
REVERSIBLE IN DIRECTION.
4. ALL LUMBER SUPPLIED SHALL BE SOUTHERN
PINE NO. 2 OR BETTER, PRESSURE TREATED.
5. ALL PLYWOOD SHALL BE EXTERIOR
EXPOSURE DURABILITY CLASSIFICATION,
GRADE C-C OR BETTER
6. NAILS SHALL BE HOT-DIP GALVANIZED.
INSTALL NAILS AND SCREW IN PATTERNS AND
QUANTITY AS SHOWN IN THE DRAWINGS.
7. ALL SCREWS, BOLTS, NUTS, AND WASHERS
SHALL BE HOTDIPPED GALVANIZED
8. POSTS TO BE SET IN TEMPORARY FENCE
WEIGHTS. DO NOT DISTURB OR DAMAGE
EXISTING SIDEWALK PAVERS.
9. RELOCATE AND REUSE BARRIER FENCE FROM
STAGE 1 TO STAGE 8 AS NEEDED
SCALE: NTS
AS1.02
BARRIER CONSTRUCTION FENCE DETAIL
EXTENT OF OVERHEAD PROTECTION. REFERENCE ELEVATION
2/A2.02 FOR SEQUENCING WITHIN STAGE 9. CONTRACTOR
CAN PROPOSE ALTERNATIVE SEQUENCING TO MAINTAIN
EGRESS REQUIREMENTS
PROTECT METAL PANEL CLADDING
FROM TEMPORARY FENCING
PROTECT EXISTING CANOPY, COORDINATE OVERHEAD
PROTECTION FOR STAGE 9
BARRIER CONSTRUCTION FENCE.
SEE DETAIL 2/AS1.02
CONTRACTOR ACCESS PATH
OVERHEAD PROTECTION
SCALE: NONE
AS1.02
SITE NORTHEAST VIEW, LOOKING WEST
AVOID PEDESTRIAN LIGHT
BOLLARDS ALONG EDGE OF PAVER
WALKWAY, SEE 3/AS1.03
AVOID PEDESTRIAN LIGHT BOLLARDS,
KEEP OUTSIDE FENCED AREA, TYP.
SIMULATED CONSTRUCTION AREA
ACCESS PATH FOR REFERENCE
TEMPORARILY RELOCATE STONE
BENCHES, RETURN TO ORIGINAL
LOCATION AFTER WORK COMPLETED
AS1.02
PROTECT EXISTING PAVERS, TYP.
DN
SCALE: 1
8"=1'-0"
AS1.03
PARTIAL SITE PLAN AND TEMPORARY
EGRESS - SOUTH ENTRANCE PLAN NORTH
DR
AF
T
CH
EC
K
DE
SI
GN
CH
EC
K
RE
VI
SI
ON
S
JOB NUMBER
DATE
SCALE
SHEET
Ga te w ay B ou le va rd
Su ite
M an as sa s, VA
-2
Of fic e:
.2
.9
To ll
Fr ee
: 8
.7
.0
Fa x:
.2
.9 w w w .w dp a.
co m
09/06/2023
09/06/2023
VC
CS
GE
RM
AN
NA
C
OM
MU
NI
TY
C
OL
LE
GE
0 G
ER
MA
NN
A
PO
IN
T
DR
IV
E, F
RE
DE
RI
CK
SB
UR
G, V
A
SC
IE
NC
E
BU
ILD
IN
G
CU
RT
AI
NW
AL
L R
EP
AI
R
PA
RT
IA
L S
IT
E
PL
AN
SO
UT
H
EN
TR
AN
CE
VR GA
D
RA
F
GA
D
21002
NTS
AS1.03
ENTRY DOORS TO REMAIN OPEN
FIRE RATED DOOR: SECURE DOOR
OPEN FOR FOR EGRESS WHEN
STAIR EXTERIOR EXIT IS BLOCKED
EXTERIOR PEDESTRIAN WALKWAY IMPACTED DURING
STAGES 8 AND 10 CONSTRUCTION PER CODE
REQUIREMENTS FOR TEMPORARY PROTECTION
PROPOSED SITE ENCLOSURE CONSTRUCTION FENCE
MA
TC
H
LIN
E
- S
EE
1/
AS
1.0
BARRIER CONSTRUCTION FENCE. SEE DETAIL 2/AS1.02
'-0
12'-10"
EXTENT OF OVERHEAD PROTECTION. REFERENCE
ELEVATION 1/A2.02 FOR SEQUENCING WITHIN STAGE 10.
CONTRACTOR CAN PROPOSE ALTERNATIVE SEQUENCING
TO MAINTAIN EGRESS REQUIREMENTS
PROTECT EXISTING CANOPY, COORDINATE OVERHEARD
PROTECTION FOR STAGE 10
INSTALL OVERHEAD PROTECTION OR TEMPORARILY BLOCK
STAIR EXIT DOOR DURING WORK HOURS WHEN BARRIER
FENCE IS REQUIRED DUE TO ADJACENT WORK (STAGES 8
AND 10). UNBLOCK AND OPEN/REMOVE TEMPORARY FENCE
WHEN NOT WORKING TO ALLOW PEDESTRIAN USE. KEEP
AREA CLEAR WHEN NOT WORKING
PROTECT METAL PANEL CLADDING
FROM TEMPORARY FENCING
NOTES:
1. SITE PLAN IS CONCEPTUAL. CONTRACTOR
SHALL SUBMIT SITE PLAN FOR REVIEW BY THE
ENGINEER OF RECORD, GERMANNA
COMMUNITY COLLEGE FACILITY DEPT, AND
CAMPUS POLICE.
2. PROTECT SITE AMENITIES, LANDSCAPING, AND
HARDSCAPES. DAMAGED ITEMS TO BE
REPLACED AT END OF PROJECT.
3. SEE AS1.04 FOR STAGING
4. RECORD DRAWING SHEET GI101, LIFE SAFETY
PLANS, ATTACHED AT THE END OF THE SET FOR
REFERENCE
LEGEND - SITE PLAN
CURTAIN WALL REPAIR
CONSTRUCTION FENCE
CONSTRUCTION FENCE DURING
STAGE 1 WORK ONLY
EXISTING SIDEWALK
OVERLAP OF SIDEWALK & CODE
RESTRICTED CONSTRUCTION AREA
CONTRACTOR ACCESS PATH
OVERHEAD PROTECTION
AS1.03
AVOID PEDESTRIAN LIGHT BOLLARDS ALONG EDGE
OF PAVER WALKWAY AND WIND TURBINE WITH
DISPLAY AND EQUIPMENT, SEE 2/AS1.03
SCALE: 1
8"=1'-0"
AS1.03
SITE SOUTH VIEW, LOOKING EAST
AVOID PEDESTRIAN LIGHT
BOLLARDS, KEEP OUTSIDE
FENCED AREA, TYP.
AVOID WIND TURBINE AND
DISPLAY, KEEP OUTSIDE
FENCED AREA
SIMULATED CONSTRUCTION
FENCE FOR REFERENCE
DN
UP
SCALE: 3
32"=1'-0"
AS1.04
PHASING PLAN
DR
AF
T
CH
EC
K
DE
SI
GN
CH
EC
K
RE
VI
SI
ON
S
JOB NUMBER
DATE
SCALE
SHEET
Ga te w ay B ou le va rd
Su ite
M an as sa s, VA
-2
Of fic e:
.2
.9
To ll
Fr ee
: 8
.7
.0
Fa x:
.2
.9 w w w .w dp a.
co m
09/06/2023
09/06/2023
VC
CS
GE
RM
AN
NA
C
OM
MU
NI
TY
C
OL
LE
GE
0 G
ER
MA
NN
A
PO
IN
T
DR
IV
E, F
RE
DE
RI
CK
SB
UR
G, V
A
SC
IE
NC
E
BU
ILD
IN
G
CU
RT
AI
NW
AL
L R
EP
AI
R
PH
AS
IN
G
PL
AN
VR GA
D
RA
F
GA
D
21002
NTS
AS1.04
1 2 3 4 5 6 7 8 9 10
C
D
A
B
H
J
2.1 2.2
2.7
3.9
4.9 6.1
7.1
8.1 8.9
9.1
3.5
C
D
J
PLAN NORTH
STAGE 3
STAGE 4
STAGE 5
STAGE 6
STAGE 7
STAGE 8
NOTES:
1. PHASES SHOWN ARE AN ESTIMATE,
CONTRACTOR TO VERIFY IN FIELD.
2. IN EACH PHASE, WORK TO BE COMPLETE ON
FIRST AND SECOND FLOOR.
3. PROVIDE TEMPORARY PROTECTION OR
CLOSE AFFECTED ROOMS IN FRONT OF
CURRENT WORK AREA.
PHASE 7 REPAIRS NOT TO INCLUDE PROTOTYPE AREA WITH THE
EXCEPTION OF PERIMETER SEALANT AT HEAD AND SILL AND AROUND
SPANDREL GLASS. REFER TO WDP REPORT IN THE PROJECT MANUAL.
REFER TO ELEVATIONS FOR EXACT PROTOTYPE LOCATION.
ST
AG
E
9STAGE 10
ST
AG
E
ST
AG
E
8'
MI
N.
UNOBSTRUCTED
WALK PATH 6'-0" MIN.
NEW TEMPORARY LIGHTING
PROPOSED, LITHONIA VR2 BY
GRAINER. NO BATTERY BACKUP.
OVERHEAD PROTECTION SHED
UPLIFT PROTECTION
AS REQUIRED
8' BARRIER
CONSTRUCTION
FENCE MOUNTED
TO PROTECTION
1'-0" 3'-0" 3'-0"
FRAME MODULES
8'
MI
N.
FRAME MODULES FRAME MODULES
8'
MI
N.
C
LE
AR
C
EI
LIN
G
HE
IG
HT
VE
RI
FY
H
EI
GH
T F
OR
LO
AD
IN
G
DO
CK
A
RE
A
NOTE:
PLYWOOD BARRIER FENCE NOT SHOWN FOR CLARITY.
EXISTING SIDEWALK OR
1'X1'X6" CONCRETE PAD, TYP.
TIE DOWNS FOR FRAMES
8' BARRIER CONSTRUCTION FENCE, TYP.
FRAME, TYP.
SCREW LEG
BEAM
JOIST
DIAGONAL BRACE
LIGHTS AT 8'
O.C.. MAX.
THE ROOF SYSTEM SHALL BE SUPPLIED AND
INSTALLED ON ALL SIDEWALK PROTECTION.
6"24 GA. GALVANIZED STEEL
COPING
4" RIGID INSULATION
(2) 2X4 BLOCKING
W/10d NAILS AT 10" O.C.
2" PLYWOOD BLOCKING
2X10 SP #2 OR BETTER
4" PLYWOOD FASCIA
EXTERIOR GRADE, PAINTED
JOIST
2X6 BLOCKING
2X4 BLOCKING
SCREWS #10X3" AT 6" O.C.
ROOF MEMBRANE
ROOFING SCREWS W/PLATE WASHERS #8X6" AT 16" O.C. EACH WAY
4" PLYWOOD
DR
AF
T
CH
EC
K
DE
SI
GN
CH
EC
K
RE
VI
SI
ON
S
JOB NUMBER
DATE
SCALE
SHEET
Ga te w ay B ou le va rd
Su ite
M an as sa s, VA
-2
Of fic e:
.2
.9
To ll
Fr ee
: 8
.7
.0
Fa x:
.2
.9 w w w .w dp a.
co m
09/06/2023
09/06/2023
VC
CS
GE
RM
AN
NA
C
OM
MU
NI
TY
C
OL
LE
GE
0 G
ER
MA
NN
A
PO
IN
T
DR
IV
E, F
RE
DE
RI
CK
SB
UR
G, V
A
SC
IE
NC
E
BU
ILD
IN
G
CU
RT
AI
NW
AL
L R
EP
AI
R
OV
ER
HE
AD
P
RO
TE
CT
IO
N
DE
TA
ILS
VR GA
D
RA
F
GA
D
21002
NTS
AS1.05
OVERHEAD PROTECTION
1. OVERHEAD PROTECTION SYSTEMS SHALL BE CONSTRUCTED FROM PROPRIETARY SYSTEMS USING STRUCTURALLY RATED COMPONENTS. ALL SCAFFOLD SYSTEM COMPONENTS SUPPLIED SHALL BE EITHER NEW OR IN EXCELLENT USED CONDITION. FINISHES FOR ALL COMPONENTS MUST BE CONSISTENT AND SHALL BE GALVANIZED OR MILL FINISH ALUMINUM. THE OWNER WILL INSPECT SYSTEMS FOR DAMAGED, DENTED, SCRATCHED, CORRODED, BENT OR OTHERWISE UNSUITABLE COMPONENTS PRIOR TO INSTALLATION.
DAMAGED COMPONENTS WILL BE REPLACED AT NO COST TO THE OWNER.
2. SYSTEMS SHALL BE DESIGNED BY THE SUPPLIER AND INSTALLED TO MEET OR EXCEED THE PERFORMANCE REQUIREMENTS LISTED. SHOP DRAWINGS SHALL BE SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN THE COMMONWEALTH OF VIRGINIA AND SUBMITTED FOR REVIEW AND APPROVAL BY THE ENGINEER AND OWNER. SYSTEMS SHALL BE ERECTED BY INSTALLERS CERTIFIED BY THE PROPRIETARY SYSTEM
MANUFACTURER OR AS OTHERWISE APPROVED IN WRITING BY THE OWNER.
3. THE DRAWINGS DEPICT THE CONCEPTUAL APPEARANCE OF THE OVERHEAD PROTECTION SYSTEM AS A MEANS OF CONVEYING THE INTENT OF THE PROTECTION DESIGN REQUIREMENTS. PROPRIETARY SYSTEMS WILL VARY IN MEMBER SIZE, NUMBER AND APPEARANCE. OVERHEAD PROTECTION SHALL TERMINATE NO
LESS THAN 20 FEET FROM STAIR TOWER ENTRIES.
4. PERFORMANCE REQUIREMENTS:
A. THE SYSTEM SHALL BE CAPABLE OF SUPPORTING A UNIFORM SERVICE LOAD OF 150 PSF APPLIED TO
THE ROOF STRUCTURE.
B. TIE DOWNS SHALL BE SUPPLIED AT EACH SHORING FRAME AND SHALL BE CAPABLE OF RESISTING A
UNIFORM UPLIFT SERVICE LOAD OF 30 PSF APPLIED TO THE ROOF SYSTEM.
C. THE MINIMUM INSIDE CLEAR CEILING HEIGHT AT OVERHEAD PROTECTION, AS MEASURED FROM THE
WALKING SURFACE, SHALL BE 8 FEET.
D. THE MINIMUM INSIDE CLEAR WIDTH OF WALKING AREAS BETWEEN FENCING, GATES AND BENEATH
OVERHEAD PROTECTION SHALL BE 6 FEET.
E. THE STRUCTURAL COMPONENTS SHALL BE POSITIVELY CONNECTED TOGETHER TO RESIST THE
SPECIFIED SERVICE LOADS. THE DECKING PLANKS SHALL BE STRUCTURALLY CONNECTED TO THE
PROPRIETARY PROTECTION SYSTEM TO RESIST A 30 PSF SERVICE UPLIFT LOAD.
F. LIGHTS SHALL BE INSTALLED IN THE OVERHEAD PROTECTION AREAS SPACED NOT MORE THAN 10 FEET ON CENTER. CONTRACTOR SHALL PROVIDE CONDUIT AND WIRING TO THE PROTECTION SYSTEMS. THE OWNER WILL PROVIDE CONNECTION POINTS AT THE BUILDING EXTERIOR WALLS. LIGHTS SHALL BE OUTDOOR, WEATHERPROOF, VANDAL-RESISTANT LED FIXTURES (70W, 120-277V) AND SHALL BE
EQUIPPED WITH TAMPER RESISTANT SCREEN COVERS.
G. THE PROPRIETARY SYSTEM SHALL BE DESIGNED SO THAT THE SPECIFIED CONSTRUCTION FENCE OR
BARRIER FENCE CAN BE MECHANICALLY ATTACHED TO THE FRAME OF THE SYSTEM.
SCALE: NTS
AS1.05
OVERHEAD PROTECTION - DETAIL
SCALE: NTS
AS1.05
TYPICAL OVERHEAD PROTECTION - SECTION
SCALE: NTS
AS1.05
TYPICAL OVERHEAD PROTECTION - ELEVATION
AS1.05
AS1.05
DN
UP
SCALE: NTS
A1.01
FIRST FLOOR REPAIR PLAN
DR
AF
T
CH
EC
K
DE
SI
GN
CH
EC
K
RE
VI
SI
ON
S
JOB NUMBER
DATE
SCALE
SHEET
Ga te w ay B ou le va rd
Su ite
M an as sa s, VA
-2
Of fic e:
.2
.9
To ll
Fr ee
: 8
.7
.0
Fa x:
.2
.9 w w w .w dp a.
co m
09/06/2023
09/06/2023
VC
CS
GE
RM
AN
NA
C
OM
MU
NI
TY
C
OL
LE
GE
0 G
ER
MA
NN
A
PO
IN
T
DR
IV
E, F
RE
DE
RI
CK
SB
UR
G, V
A
SC
IE
NC
E
BU
ILD
IN
G
CU
RT
AI
NW
AL
L R
EP
AI
R
FI
RS
T
FL
OO
R
RE
PA
IR
P
LA
N
VR GA
D
RA
F
GA
D
21002
NTS
A1.01
1 2 3 4 5 6 7 8 9 10
C
D
A
B
H
J
2.1 2.2
2.7
3.9
4.9 6.1
7.1
8.1 8.9
9.1
3.5
C
D
J
1 & 6 A2.01
2 & 6 A2.01
A3.01
PLAN NORTH
3 & 4 A2.01
149'-3"
38'-11 1 4 "
PLAN EAST
PLAN NORTHPLAN SOUTH
PHASE 7 REPAIRS NOT TO INCLUDE PROTOTYPE AREA WITH THE
EXCEPTION OF PERIMETER SEALANT AT HEAD AND SILL AND AROUND
SPANDREL GLASS. REFER TO WDP REPORT IN THE PROJECT MANUAL.
REFER TO ELEVATIONS FOR EXACT PROTOTYPE LOCATION.
A2.02
A3.01
A3.02
A3.02
A2.02
A2.02
1A A5.01
EXISTING ENTRY
CANOPY ABOVE
DO NOT DISTURB EXISTING EXIT
SIGN MOUNTED ON CW FRAME
OVER EXTERIOR EXIT DOOR, TYP
EXISTING ENTRY
CANOPY ABOVE
DN DN
UP UP
SCALE: 3
32"=1'-0"
A1.02
SECOND FLOOR REPAIR PLAN
DR
AF
T
CH
EC
K
DE
SI
GN
CH
EC
K
RE
VI
SI
ON
S
JOB NUMBER
DATE
SCALE
SHEET
Ga te w ay B ou le va rd
Su ite
M an as sa s, VA
-2
Of fic e:
.2
.9
To ll
Fr ee
: 8
.7
.0
Fa x:
.2
.9 w w w .w dp a.
co m
09/06/2023
09/06/2023
VC
CS
GE
RM
AN
NA
C
OM
MU
NI
TY
C
OL
LE
GE
0 G
ER
MA
NN
A
PO
IN
T
DR
IV
E, F
RE
DE
RI
CK
SB
UR
G, V
A
SC
IE
NC
E
BU
ILD
IN
G
CU
RT
AI
NW
AL
L R
EP
AI
R
SE
CO
ND
F
LO
OR
R
EP
AI
R
PL
AN
VR GA
D
RA
F
GA
D
21002
NTS
A1.02
1 2 3 4 5 6 7 8 9 10
C
D
A
B
H
J
2.1 2.2
2.7
3.9
4.9 6.1
7.1
8.1 8.9
9.1
3.5
C
D
J
A3.01
PLAN NORTH
149'-3"
38'-11 1 4 "
A2.01
A2.01
A2.01
PHASE 7 REPAIRS NOT TO INCLUDE PROTOTYPE AREA WITH THE
EXCEPTION OF PERIMETER SEALANT AT HEAD AND SILL AND AROUND
SPANDREL GLASS. REFER TO WDP REPORT IN THE PROJECT MANUAL.
REFER TO ELEVATIONS FOR EXACT PROTOTYPE LOCATION.
A2.02
A3.01
A3.02
A3.02
A2.02
A2.02
1B A5.01
A2.02
SIM.
A2.01
3R D
FL
OO
R
NO
T S
HO
W N, R
EP
AI
R
CU
RT
AI
N
W
AL
L A
ND
R
EP
LA
CE
S
PA
ND
RE
L G
LA
SS
A
T
NO
RT
H
AN
D
SO
UT
H
EL
EV
AT
IO
NS
EXISTING ENTRY CANOPY,
LOW-SLOPE BATTEN SEAM
METAL ROOF
A2.01
NOTE:
3RD FLOOR PLAN NOT SHOWN, SEE 2ND FLOOR PLAN NOTES, ELEVATIONS, AND SECTIONS.
RECORD DRAWING SHEET AE103, THIRD FLOOR PLAN, ATTACHED AT THE END OF THE SET FOR
REFERENCE
REPAIR WHERE CEILING
GWB CUT FOR TEMPORARY
ACCESS NEAR THE OPEN
STAIRWAY, 2 LOCATIONS
APPROXIMATELY 24"X24"
REPLACED DAMAGED GWB IN ROLLER
SHADE POCKET AND REPAINT TO
MATCH EXISTING, SEE 3/A1.02
REMOVE AND REINSTALL
EXISTING SUNSHADE TO
PERFORM CW REPAIRS, TYP.
EXISTING SUNSHADES ABOVE, SEE 5/A2.02
AND CW SHOP DRAWING G-5.XX DETAILS
REMOVE AND REINSTALL
EXISTING SUNSHADE TO
PERFORM CW REPAIRS, TYP.
EXISTING ENTRY CANOPY, LOW-SLOPE
BATTEN SEAM METAL ROOF
A5.01
SIM.
A5.01
A2.01
A1.02
TYPICAL ROLLER SHADE POCKET DAMAGE
VIEW LOOKING UP AT CEILING,
INTO GWB POCKET
REPLACED DAMAGED
GWB IN ROLLER SHADE
POCKET AND REPAINT TO
MATCH EXISTING
A2.02
DR
AF
T
CH
EC
K
DE
SI
GN
CH
EC
K
RE
VI
SI
ON
S
JOB NUMBER
DATE
SCALE
SHEET
Ga te w ay B ou le va rd
Su ite
M an as sa s, VA
-2
Of fic e:
.2
.9
To ll
Fr ee
: 8
.7
.0
Fa x:
.2
.9 w w w .w dp a.
co m
09/06/2023
09/06/2023
VC
CS
GE
RM
AN
NA
C
OM
MU
NI
TY
C
OL
LE
GE
0 G
ER
MA
NN
A
PO
IN
T
DR
IV
E, F
RE
DE
RI
CK
SB
UR
G, V
A
SC
IE
NC
E
BU
ILD
IN
G
CU
RT
AI
NW
AL
L R
EP
AI
R
DE
SI
GN
CU
RT
AI
N
W
AL
L E
LE
VA
TI
ON
S
VR GA
D
RA
F
GA
D
21002
AS NOTED
A2.01
2.2 2.7 3.9 4.9 6.1 7.1 8.1 9.1
1ST FLOOR
0'-0"
2ND FLOOR
15'-0"
THIRD FLOOR
29'-0"
SCALE: 3
16"=1'-0"
A2.01
CURTAIN WALL
EAST ELEVATION REPAIR
1B A5.01
A5.01
A5.01
1A A5.01
A5.01
NOTES:
1. THIS ELEVATION IS DRAWN AS A FLAT REPRESENTATION OF SEGMENTED WALL. CONTRACTOR TO FIELD VERIFY.
2. CONTRACTOR TO FIELD VERIFY DIMENSIONS OF ANY BROKEN GLAZING.
1'-81 4"
9'-113 4" 25'-31
8" 25'-31 8" 25'-31
8" 25'-31 8" 25'-31
8" 9'-113 4"
1'-81 4"
3'- 6"
6'-
1 2" 4'-
61 2" 3'-
6" 5'-
6" 4'-
1 2"
GLAZING SCHEDULE
GL1 LOW-E CLEAR INSULATING GLASS
GL1T LOW-E CLEAR INSULATING TEMPERED GLASS
GL8 GL8 TO BE REPLACED WITH LAMINATED GLASS. COLOR
TO MATCH EXISTING. SUBMIT SAMPLE FOR APPROVAL.
SCALE: 3
16"=1'-0"
A2.01
CURTAIN WALL
SOUTH ELEVATION REPAIR
1ST FLOOR
0'-0"
2ND FLOOR
15'-0"
THIRD FLOOR
29'-0"
SCALE: 3
16"=1'-0"
A2.01
CURTAIN WALL
NORTH ELEVATION REPAIR
A5.01
1A A5.01
GL8 GL8 GL8 GL8
GL1 GL1 GL1 GL1
GL1T GL1T GL1T GL1T
GL8 GL8 GL8 GL8
GL1 GL1 GL1 GL1
GL1T GL1T GL1T GL1T
A5.01
A5.01
GL8
GL1
GL1T
1A A5.01
1B A5.01
LOCATION OF PROTOTYPE. PERIMETER SEALANT AT HEAD
AND SILL OF PROTOTYPE TO BE REPLACED. SPANDREL
GLASS TO BE REPLACED. ALL OTHER REPAIRS ALREADY
COMPLETED IN THIS SECTION AS PART OF THE PROTOTYPE
REPAIR. REFER TO WDP REPORT IN THE PROJECT MANUAL.
SCALE: NTS
A2.01
PHOTOGRAPH 3
LIBRARY EAST AND NORTH ELEVATIONS
A2.01
PHOTOGRAPH 1
LIBRARY SOUTH ELEVATION
SCALE: NTS
A2.01
PHOTOGRAPH 2
LIBRARY SOUTH ELEVATION SUNSHADES
SCALE: NTS
SUNSHADES NOT SHOWN FOR CLARIFY, SEE PHOTOGRAPH 4/A2.01
AND 3/A2.02.
1ST FLOOR
0'-0"
2ND FLOOR
15'-0"
3RD FLOOR
29'-0"
MA
TC
H
LIN
E
- S
EE
2/
A2 .02
MA
TC
H
LIN
E
- S
EE
1/
A2 .02
A3.01
A3.01
A5.01
A5.01
A2.02
A2.01
T
CH
EC
K
DE
SI
GN
CH
EC
K
RE
VI
SI
ON
S
JOB NUMBER
DATE
SCALE
SHEET
Ga te w ay B ou le va rd
Su ite
M an as sa s, VA
-2
Of fic e:
.2
.9
To ll
Fr ee
: 8
.7
.0
Fa x:
.2
.9 w w w .w dp a.
co m
09/06/2023
09/06/2023
VC
CS
GE
RM
AN
NA
C
OM
MU
NI
TY
C
OL
LE
GE
0 G
ER
MA
NN
A
PO
IN
T
DR
IV
E, F
RE
DE
RI
CK
SB
UR
G, V
A
SC
IE
NC
E
BU
ILD
IN
G
CU
RT
AI
NW
AL
L R
EP
AI
R
DE
SI
GN
CU
RT
AI
N
W
AL
L E
LE
VA
TI
ON
S
VR GA
D
RA
F
GA
D
21002
NTS
A2.02
SCALE: 3
16"=1'-0"
A2.02
CURTAIN WALL
SOUTH ELEVATION REPAIR
1ST FLOOR
0'-0"
2ND FLOOR
15'-0"
3RD FLOOR
29'-0"
SCALE: 3
16"=1'-0"
A2.02
CURTAIN WALL
NORTH ELEVATION REPAIR
1ST FLOOR
0'-0"
2ND FLOOR
15'-0"
3RD FLOOR
29'-0"
MA
TC
H
LIN
E
- S
EE
3/
A2 .01
MA
TC
H
LIN
E
- S
EE
2/
A2 .01
GLAZING SCHEDULE
GL1 LOW-E CLEAR INSULATING GLASS
GL1T LOW-E CLEAR INSULATING TEMPERED GLASS
GL8 GL8 TO BE REPLACED WITH LAMINATED GLASS. COLOR
TO MATCH EXISTING. SUBMIT SAMPLE FOR APPROVAL.
1ST FLOOR
0'-0"
2ND FLOOR
15'-0"
3RD FLOOR
29'-0"
SCALE: 1
2"=1'-0"
A2.02
LIBRARY SOUTH SECTION AT SUNSCREEN
A3.01
EXISTING MINERAL WOOL INSULATION TO
REMAIN, RESECURE AS NEEDED AND
REPLACE ANY MISSING AREAS
EXISTING GLAZED ALUMINUM CURTAINWALL
EXISTING ROLLER WINDOW SHADE
EXISTING GLAZED ALUMINUM CURTAINWALL
EXISTING ROLLER WINDOW SHADE
3'- 6"
6'- 6"
5'- 0"
3'- 6"
5'- 3"
5'- 9"
A5.01
A5.01
NOTES:
1. REFER TO SHEET A3.01 FOR REPAIR NOTES
2. SUNSHADES TO BE REMOVED FOR REPAIRS. ALL SUNSHADES TO BE CLEANED.
SUNSHADES TO BE REINSTALLED TO MATCH EXISTING.
SEQUENCING PLAN FOR STAGE 9 & 10:
A. BEGIN WITH 2ND AND 3RD FLOOR REPAIRS WHILE PROVIDING OVERHEAD PROTECTION AT ALL DOORS.
B. COMPLETE REPAIRS TO THE STAIRWELL DOOR WHILE PROVIDING A BARRIER FENCE
C. COMPLETE REPAIRS TO MIDDLE DOORS WHILE PROVIDING A BARRIER FENCE TO ALLOW PEDESTRIANS TO EXIT VIA
THE END SET OF DOUBLE DOORS0
D. COMPLETE REPAIRS TO THE FINAL SET OF DOUBLE DOORS, PROVIDING A BARRIER FENCE BETWEEN THE BRICK
AND DOOR TO ALLOW PEDESTRIANS TO USE THE STAIRWELL AND MIDDLE SET OF DOORS.
NOTE:
CONTRACTOR CAN PROPOSE ALTERNATIVE SEQUENCING TO MAINTAIN EGRESS REQUIREMENTS.
EXISTING DOOR GLAZING TO REMAIN, NOT IN SCOPE.
SEQUENCE A: OVERHEAD
PROTECTION ACROSS ALL DOORS
SEQUENCE D: REPAIRS TO WEST
END AREA UNDER THE CANOPY,
BARRIER FENCE
SEQUENCE C: REPAIRS TO MIDDLE
AREA UNDER THE CANOPY,
BARRIER FENCE
SEQUENCE B: REPAIRS TO
STAIRWELL AREA UNDER THE
CANOPY, BARRIER FENCE
SEQUENCE A: OVERHEAD
PROTECTION ACROSS ALL DOORS
SEQUENCE D: REPAIRS TO
STAIRWELL WEST END AREA
UNDER CANOPY, BARRIER FENCE
SEQUENCE B: REPAIRS TO END
STAIRWELL AREA UNDER CANOPY,
BARRIER FENCE
SEQUENCE C: REPAIRS TO MIDDLE
AREA UNDER THE CANOPY,
BARRIER FENCE
EX
IS
TI
NG
S
PA
ND
RE
L
TO
B E
RE
PL
AC
ED
EX
IS
TI
NG
S
PA
ND
RE
L
TO
B E
RE
PL
AC
ED
CONTINUOUS HORIZONTAL
MULLION, SEE 6/A5.01
SIM.
EXISTING IGU TO BE REMOVED, CLEANED AS
NEEDED, AND REINSTALLED, TYP. SEE A3.01
NOTES AND SPECIFICATIONS. REFER TO
ORIGINAL CURTAIN WALL SHOP DRAWINGS
FOR ADDITIONAL INFORMATION
EXISTING SUNSHADE TO BE REMOVED,
CLEANED AS NEEDED, AND REINSTALLED,
TYP. SEE 1B/A5.01 FOR SOUTHEAST CORNER
CONDITION. REFER TO ORIGINAL CURTAIN
WALL SHOP DRAWINGS FOR ADDITIONAL
INFORMATION
A3.02
A5.01
A3.02
A3.02
NOTE: SUNSHADES NOT SHOWN FOR CLARITY, SEE 4/A2.02 (SIM) AND 1/A3.02NOTE: SUNSHADES NOT SHOWN FOR CLARITY, SEE 4/A2.02 (SIM) AND 1/A3.02
A5.01
SIM
A5.01
A5.01
A2.02
3-STORY SOUTH ELEVATION 5
A2.02
3-STORY ELEVATION SUNSHADES
SCALE: 11
2"=1'-0"
A3.01
EXISTING CURTAINWALL SECTION
AT LOW ROOF, EXISTING ROOFING REMOVAL
DR
AF
T
CH
EC
K
DE
SI
GN
CH
EC
K
RE
VI
SI
ON
S
JOB NUMBER
DATE
SCALE
SHEET
Ga te w ay B ou le va rd
Su ite
M an as sa s, VA
-2
Of fic e:
.2
.9
To ll
Fr ee
: 8
.7
.0
Fa x:
.2
.9 w w w .w dp a.
co m
09/06/2023
09/06/2023
VC
CS
GE
RM
AN
NA
C
OM
MU
NI
TY
C
OL
LE
GE
0 G
ER
MA
NN
A
PO
IN
T
DR
IV
E, F
RE
DE
RI
CK
SB
UR
G, V
A
SC
IE
NC
E
BU
ILD
IN
G
CU
RT
AI
NW
AL
L R
EP
AI
R
CU
RT
AI
N W
AL
L S
EC
TI
ON
VR GA
D
RA
F
GA
D
21002
NTS
A3.01
1ST FLOOR
0'-0"
2ND FLOOR
15'-0"
3RD FLOOR
29'-0"
SCALE: 1
2"=1'-0"
A3.01
LIBRARY EAST & NORTH SECTION
A3.01
EXISTING FIN BEYOND
EXISTING CURTAIN WALL FRAMING TO REMAIN
EXISTING MINERAL WOOL INSULATION
TO REMAIN, RESECURE AS NEEDED
AND REPLACE ANY MISSING AREAS
EXISTING 14" SPANDREL GLASS TO BE
REMOVED AND REPLACED (GL8),
TYPICAL
REMOVE EXISTING SEALANT, SEE PHOTO 3 (5/A3.01)
CUT AND REMOVE PORTION OF EXISTING
TPO MEMBRANE, SEE PHOTO 1 (3/A3.01)
REMOVE TPO FLASHING STRIP AND METAL
EDGE FLASHING, SEE PHOTOS 1 & 2 (3 & 4/A3.01)
EXISTING MINERAL WOOL INSULATION TO
REMAIN, RESECURE AS NEEDED AND
REPLACE ANY MISSING AREAS
EXISTING GLAZED ALUMINUM CURTAINWALL
EXISTING ROLLER WINDOW SHADE
EXISTING GLAZED ALUMINUM CURTAINWALL
EXISTING ROLLER WINDOW SHADE
3'- 6"
6'-
0" 5'-
0" 3'-
6" 5'-
3" 5'-
9"
A5.01
A5.01
A3.01
A3.01
A3.01
SCALE: NONE
A3.01
PHOTOGRAPH 1
SCALE: NONE
A3.01
PHOTOGRAPH 2
SCALE: NONE
A3.01
PHOTOGRAPH 3
GENERAL NOTES:
1. REINSTALLATION OF CURTAIN WALL COMPONENTS PER MANUFACTURER'S INSTRUCTIONS AND
APPROVED SHOP DRAWINGS.
2. ALL REUSED EXISTING COMPONENTS TO BE THOROUGHLY CLEANED BEFORE REINSTALLATION.
3. NEW EXTERIOR GASKETS AT ALL LOCATIONS. INTERIOR GASKETS TO BE INSPECTED AND
REPLACED AS NEEDED.
4. HORIZONTAL AND VERTICAL JOINT STOPS TO BE REPLACED. SETTING BLOCKS TO BE REPLACED.
5. REMOVE AND REINSTALL PERIMETER JOINT SEALANT.
6. INSTALL AND TEST SPANDREL MOCKUP BEFORE PROCEEDING.
7. SEE SPECIFICATION FOR ADDITIONAL REQUIREMENTS, INCLUDING FIELD TESTING
FRAME NOTES
1. EXISTING FRAME TO REMAIN IN PLACE
2. SEAL FACE, TOP, BOTTOM, AND SCREW TRACKS OF SHEAR BLOCKS AS NEEDED. ADEQUATE
SEALANT SHOULD BE APPLIED IN TRACK OF SHEAR BLOCK TO ALLOW SEALANT TO FORCE
THROUGH HOLES IN HORIZONTAL.
3. SEALANT SHOULD FORM A SEAL AROUND AND BENEATH ATTACHMENT FASTENERS. IF SEALANT
DOES NOT FORM COMPLETE SEAL AROUND SCREW HEAD, THE FASTENER SHOULD BE CAP
SEALED TO INSURE A PROPER SEAL.
4. WIPE EXCESS SEALANT FROM EXPOSED AREAS. TOOL SEALANT INTO THE JOINT BETWEEN THE
HORIZONTAL AND VERTICAL AT THE GLAZING POCKET. AVOID A BUILDUP OF SEALANT ON THE
GASKET SURFACES OR IN THE GASKET REGLETS.
5. INSTALL NEW ZONE PLUGS
6. APPLY SEALANT TO ALL CONTACT SURFACES ON VERTICAL AND HORIZONTAL MULLIONS WHERE
ZONE PLUGS WILL BE INSTALLED. APPLY SEALANT TO HORIZONTAL TONGUE RECEPTOR ON
ZONE PLUG AND INSTALL AT THE END OF EACH HORIZONTAL, HEAD, AND SILL. TOOL ANY
EXCESS SEALANT AROUND FRONT END OF ZONE PLUG WHERE THERMAL SPACER ABUTS THE
ZONE PLUG. TOOL SEALANT IN GLAZING POCKETS.
7. APPLY PERIMETER SEAL. SEAL ALONG TONGUE OF HORIZONTAL AND ACROSS FACE OF MULLION
BEFORE INSTALLING ZONE BRIDGE. FORCE SEALANT INTO ALL RACES ON FACE OF MULLION.
TOOL SEALANT ALONG TOP AND SIDES OF ZONE BRIDGE TO FORM A WATER TIGHT SEAL.
ENSURE FREE FLOW OF WATER FROM VERTICAL TO HORIZONTAL DRAINAGE PATH, CORRECT
OBSTRUCTIONS BY EXCESSIVE SEALANT AND INTERIOR GASKETS.
THERMAL ISOLATOR NOTES:
1. INSTALL NEW THERMAL ISOLATORS PER THE MANUFACTURER'S INSTRUCTIONS
GLAZING NOTES
1. EXISTING IGUS TO BE CLEANED AND REUSED. SPANDREL TO BE REPLACED AND NEW GLAZING
POCKET ADAPTERS FOR THICKER LAMINATED GLASS
2. CHECK TO ENSURE INTERIOR GASKET IS PROPER SIZED (NOT TOO SHORT OR TOO LONG) AND
NO GAP OR OVERLAP (BUCKLING) IN THE CORNERS. WET SEAL CORNERS BEFORE RESETTING
GLASS
3. SET GLASS IN OPENING. ENSURE THE CORRECT GLASS BITE IS MAINTAINED ON ALL SIDES. BE
CERTAIN THAT GLASS IS PLACED FIRMLY AGAINST INTERIOR GASKET TO ENSURE A PROPER
SEAL AND TO AVOID BINDING OF THE GLASS ON SETTING BLOCKS
4. TEMPORARILY HOLD GLASS IN THE OPENING PER MANUFACTURER’S INSTRUCTIONS
PRESSURE PLATE NOTES:
1. EXISTING PRESSURE PLATES TO BE CLEANED AND REUSED
2. ENSURE THAT SCREWS IN THE PRESSURE PLATE ARE SPACED PROPERLY ACCORDING TO
MANUFACTURER'S INSTRUCTIONS, SPECIALLY AT ENDS. CORRECT IMPROPER SPACING WITH
NEW HOLES/SCREWS AND FILL UNUSED HOLES PROPERLY
3. PRIOR TO INSTALLING PRESSURE PLATES, APPLY SEALANT TO THE FACE OF EACH ZONE PLUG.
VERTICAL PRESSURE PLATES MUST BE INSTALLED BEFORE THE HORIZONTAL PRESSURE
PLATES ARE APPLIED.
4. AFTER REMOVING VERTICAL TEMPORARY RETAINERS, INSTALL VERTICAL PRESSURE PLATES, HOLDING BACK 1/8” FROM THE ENDS OF THE VERTICAL MULLION
5. AFTER REMOVING HORIZONTAL TEMPORARY RETAINERS, CENTER HORIZONTAL PRESSURE
PLATES IN OPENING, LEAVING 1/8” GAP ON EACH END. MAKE SURE THAT THE WEEP HOLES ARE
ON THE TOP SIDE OF THE PRESSURE PLATE AND UNOBSTRUCTED. HORIZONTAL PRESSURE
PLATES AND FACE COVERS RUN CONTINUOUS OVER MULLIONS, NOT TO EXCEED 3 LITES IN
LENGTH. APPLY FACE CAP TO CONTINUOUS PRESSURE PLATES ONLY.
6. TORQUE SCREWS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.
SEALING TOP OF VERTICAL AND FACE COVER NOTES:
1. EXISTING FACE COVERS TO BE CLEANED AND REUSED.
2. INSERT BACKER ROD INTO CAVITY AT THE TOP OF EACH VERTICAL MULLION. SEAL OFF END OF
VERTICAL, SLOPING SEALANT BACK TO MARRY WITH THE PERIMETER SEAL.
3. SEAL HORIZONTAL PRESSURE PLATES AGAINST THE VERTICAL FACE COVERS. TOOL SEALANT
INTO THE JOINT.
4. INSTALL HORIZONTAL FACE COVERS, LEAVING AN EQUAL GAP AT EACH END. MAKE SURE THAT
WEEP HOLES IN THE FACE COVER ARE ON THE BOTTOM AND UNOBSTRUCTED.
5. REFER TO MANUFACTURER’S INSTRUCTIONS FOR FACE CAP INSTALLATION
INTERIOR:
1. DRYWALL TO BE REPAIRED AT LOCATIONS WHERE DAMAGED BY WATER LEAKAGE OR CURTAIN
WALL REPAIRS; MATCH EXISTING.
2. PAINT TO BE REPAIRED AT LOCATIONS WHERE DAMAGED BY WATER LEAKAGE OR CURTAIN
WALL REPAIRS; MATCH EXISTING.
3. BLINDS TO BE REPAIRED BY GERMANNA COMMUNITY COLLEGE.
SPANDREL NOTES:
1. EXISTING GLAZING ADAPTERS TO BE REMOVED, CLEANED AND REUSED. REPLACE ANY
DAMAGED ITEMS.
2. ENSURE TO USE NARROW SETTING BLOCKS, DO NOT USED MODIFIED STANDARD SETTING
BLOCKS.
3. REINSTALL EXISTING GLAZING ADAPTERS BY SEALING INTO RECEIVER SLOT AND, ENSURE
CORNERS ARE SEALED BACK TO THE GLASS FACE.
CUT BACK EXISTING TPO
FLASHING MEMBRANE
REMOVE EXISTING METAL
EDGE FLASHING
NOTE:
1. SEE DETAIL 1/A5.02 FOR REPAIR
SEE DETAIL 1/A5.02 FOR ROOF REPAIR WORK
EX
IS
TI
NG
S
PA
ND
RE
L
TO
B E
RE
PL
AC
ED
EX
IS
TI
NG
S
PA
ND
RE
L
TO
B E
RE
PL
AC
ED
CONTINUOUS HORIZONTAL
MULLION, SEE 6/A5.01
EXISTING IGU TO BE REMOVED, CLEANED AS
NEEDED, AND REINSTALLED, TYP. SEE A3.01
NOTES AND SPECIFICATIONS. REFER TO
ORIGINAL CURTAIN WALL SHOP DRAWINGS
FOR ADDITIONAL INFORMATION
A5.02
SCALE: 11
2"=1'-0"
A3.02
EXISTING CURTAINWALL SECTION
AT 3-STORY ROOF, EXISTING ROOFING REMOVAL
DR
AF
T
CH
EC
K
DE
SI
GN
CH
EC
K
RE
VI
SI
ON
S
JOB NUMBER
DATE
SCALE
SHEET
Ga te w ay B ou le va rd
Su ite
M an as sa s, VA
-2
Of fic e:
.2
.9
To ll
Fr ee
: 8
.7
.0
Fa x:
.2
.9 w w w .w dp a.
co m
09/06/2023
09/06/2023
VC
CS
GE
RM
AN
NA
C
OM
MU
NI
TY
C
OL
LE
GE
0 G
ER
MA
NN
A
PO
IN
T
DR
IV
E, F
RE
DE
RI
CK
SB
UR
G, V
A
SC
IE
NC
E
BU
ILD
IN
G
CU
RT
AI
NW
AL
L R
EP
AI
R
CU
RT
AI
N W
AL
L S
EC
TI
ON
VR GA
D
RA
F
GA
D
21002
NTS
A3.02
1ST FLOOR
0'-0"
3RD FLOOR
29'-0"
TOS/ROOF
43'-0"
SCALE: 3
8"=1'-0"
A3.02
ENTRY WALL SECTION
A3.02
EXISTING MINERAL WOOL INSULATION
EXISTING GLAZED ALUMINUM CURTAINWALL
A3.02
7'- 0"
3'- 0"
3'- 0"
2'- 0"
3'- 6"
5'- 0"
5'- 6"
3'- 6"
5'- 6"
5'-
EXISTING GLASS FIBER BOARD INSULATION
EXISTING GLAZED ALUMINUM CURTAINWALL
EXISTING CURTAIN WALL
FRAMING TO REMAIN
EXISTING 14" SPANDREL GLASS TO BE
REMOVED AND REPLACED (GL-8), TYPICAL
REMOVE EXISTING SEALANT
CUT AND REMOVE PORTION OF
EXISTING TPO MEMBRANE
REMOVE TPO FLASHING STRIP
AND METAL EDGE FLASHING
SEE DETAIL 2/A5.02 FOR
ROOF REPAIR WORK
SCALE: 11
2"=1'-0"
A3.02
EXISTING CURTAINWALL SECTION
AT ENTRY CANOPY
EXISTING 14" SPANDREL GLASS TO BE
REMOVED AND REPLACED (GL8),
TYPICAL
EXISTING METAL ROOF AND
FLASHING TO REMAIN
EXISTING IGU TO BE REMOVED,
CLEANED AS NEEDED, AND
REINSTALLED, TYP.
2ND FLOOR
15'-0"
EX
IS
TI
NG
S
PA
ND
RE
L
TO
B E
RE
PL
AC
ED
EX
IS
TI
NG
S
PA
ND
RE
L
TO
B E
RE
PL
AC
ED
EX
IS
TI
NG
S
PA
ND
RE
L
TO
B E
RE
PL
AC
ED
EXISTING SUNSHADE, REMOVE AND
REINSTALL, TYP. REFER TO ORIGINAL
CURTAIN WALL SHOP DRAWINGS FOR
ADDITIONAL INFORMATION
EXISTING IGU TO BE REMOVED, CLEANED AS
NEEDED, AND REINSTALLED, TYP. SEE A3.01
NOTES AND SPECIFICATIONS. REFER TO
ORIGINAL CURTAIN WALL SHOP DRAWINGS
FOR ADDITIONAL INFORMATION
EXISTING SUNSHADE, REMOVE AND
REINSTALL, TYP. REFER TO ORIGINAL
CURTAIN WALL SHOP DRAWINGS FOR
ADDITIONAL INFORMATION
EXISTING MINERAL WOOL
INSULATION TO REMAIN
EXISTING JOINT SEALANT TO BE REMOVED
AND NEW INSTALLED, CLEAN AND PREPARE
SUBSTRATE AS NEEDED AND CONFIRM
PROPER ADHESION
EXISTING METAL CEILING TO
REMAIN
EXISTING CURTAIN WALL FRAMING TO
REMAIN, TYP.
EXISTING IGU TO BE REMOVED,
CLEANED AS NEEDED, AND
REINSTALLED, TYP.
A5.02
EX
IS
TI
NG
G
LA
SS
DO
OR
S
NO
T
IN
S
CO
PE
2ND FLOOR
15'-0"
A5.01
SCALE: 6"=1'-0"
A5.01
SILL AT CURTAINWALL REPAIR DETAIL
DR
AF
T
CH
EC
K
DE
SI
GN
CH
EC
K
RE
VI
SI
ON
S
JOB NUMBER
DATE
SCALE
SHEET
Ga te w ay B ou le va rd
Su ite
M an as sa s, VA
-2
Of fic e:
.2
.9
To ll
Fr ee
: 8
.7
.0
Fa x:
.2
.9 w w w .w dp a.
co m
09/06/2023
09/06/2023
VC
CS
GE
RM
AN
NA
C
OM
MU
NI
TY
C
OL
LE
GE
0 G
ER
MA
NN
A
PO
IN
T
DR
IV
E, F
RE
DE
RI
CK
SB
UR
G, V
A
SC
IE
NC
E
BU
ILD
IN
G
CU
RT
AI
NW
AL
L R
EP
AI
R
RE
PA
IR
D
ET
AI
LS
VR GA
D
RA
F
GA
D
21002
NTS
A5.01SCALE: 6"=1'-0"
A5.01
CURTAINWALL DETAIL AT SLAB
SCALE: 12"=1'-0"
A5.01
THERMAL ISOLATOR
DETAIL AT CONTINUOUS HORIZONTAL MULLION
SCALE: 3"=1'-0"
1A A5.01
CORNER DETAIL
AT CURTAINWALL REPAIR
SCALE: 6"=1'-0"
A5.01
CURTAINWALL JAMB AT METAL PANEL REPAIR
SCALE: 6"=1'-0"
A5.01
TYPICAL VERTICAL
CURTAINWALL MULLION REPAIR
EXISTING GLASS TO BE REMOVED AND
REINSTALLED FOLLOWING REPAIRS
REPLACEMENT EXTERIOR GASKET, TYP.
EXISTING INTERIOR GASKET TO BE
INSPECTED AND REPLACED AS
NEEDED, TYP.
EXISTING BEAUTY CAP TO BE REMOVED
AND REINSTALLED FOLLOWING REPAIRS
EXISTING BACKER ROD AND SEALANT TO BE REMOVED
AND REPLACED WITH NEW, TYP. CLEAN CONCRETE
SUBSTRATE AND PRIME AS NEEDED, TEST FOR PROPER
ADHESION. ENSURE SHIMS DON'T INTERFERE WITH
PROPER SEALANT DEPTH
ENSURE CAP WEEPS ARE CLEAR
EXISTING GLASS TO BE REMOVED AND
REINSTALLED FOLLOWING REPAIRS
REPLACEMENT EXTERIOR GASKET, TYP.
EXISTING INTERIOR GASKET TO BE
INSPECTED AND REPLACED AS NEEDED, TYP.
REPLACEMENT EXTERIOR GASKET, TYP.
EXISTING SPANDREL GLASS TO BE
REMOVED AND REPLACED (GL8), TYP.
REPLACE INTERIOR GASKET AT NEW
SPANDREL GLASS, TYP.
EXISTING MINERAL WOOL INSULATION
TO REMAIN, RESECURE AS NEEDED
AND REPLACE ANY MISSING AREAS
REPLACE STRUCTURAL
SEALANT AND BACKER ROD,
TYPICAL AT OUTSIDE
CORNERS
EXISTING GLASS TO BE REMOVED AND
REINSTALLED FOLLOWING REPAIRS
REPLACEMENT EXTERIOR GASKET, TYP.
INTERIOR GASKET TO BE INSPECTED
AND REPLACED AS NEEDED, TYP.
EXISTING BEAUTY CAP TO BE REMOVED
AND REINSTALLED FOLLOWING REPAIRS
EXISTING PREFINISHED ALUMINUM
TRIM TO REMAIN, TYP.
EXISTING COMPOSITE WALL PANEL
TO REMAIN, TYP.
REMOVE AND REINSTALL
EXISTING ALUMINUM COVER
EXISTING PRESSURE PLATE TO BE
REMOVED, CLEANED, AND REINSTALLED
SPACING OF SCREWS INTO PRESSURE
PLATE TO BE ADJUSTED PER
MANUFACTURER'S INSTRUCTIONS,
UNUSED HOLES TO BE FILLED PROPERLY
SPACING OF SCREWS INTO PRESSURE
PLATE TO BE ADJUSTED PER
MANUFACTURER'S INSTRUCTIONS,
UNUSED HOLES TO BE FILLED PROPERLY
GLASS TO BE REMOVED AND
REINSTALLED FOLLOWING
REPAIRS
REPLACEMENT
EXTERIOR GASKET, TYP.
INTERIOR GASKET TO BE
INSPECTED AND REPLACED
AS NEEDED, TYP.
EXISTING PRESSURE PLATE TO BE
REMOVED, CLEANED, AND REINSTALLED
SPACING OF…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .