Gardner MS Roof Replacement Bid Plans .pdf

PDF 25 MB Posted

Attached to
2026-032 GMS MSBA Accelerated Repair Program Roof Replacement Project
Solicitation number
BD-26-1441-COG01-COG01-126408
Issued by
Massachusetts

About this file

This bid document set consists of architectural, structural, mechanical, plumbing, and electrical drawings prepared by Tighe & Bond for the Gardner Middle School MSBA Accelerated Repair Program Roof Replacement Project located in Gardner, Massachusetts. The project, issued for bidding in March 2026, encompasses the complete removal and replacement of existing roofing systems across multiple roof levels, installation of new HVAC equipment and controls, plumbing modifications including new roof drains and vent pipes, electrical system updates, and accessibility improvements. The scope includes demolition of existing EPDM and metal roofing systems, installation of new rigid insulation with minimum R-30 value and 6-inch thickness, new membrane and metal roofing applications, replacement of roof drains and vent penetrations, removal and reinstallation of existing mechanical equipment on new curbs with minimum 12-inch clearance above roof surface, and associated structural repairs. The 71-sheet drawing set provides detailed specifications for base bid work and Alternate No. 1, which includes replacement of existing HVAC air handling units with new rooftop units and condensing units. The project includes provisions for future photovoltaic system installation on designated roof areas with maximum 3 PSF solar weight capacity, requiring 2-inch empty conduit infrastructure routed through the building to the electrical room.

Funding for the project is provided through the Massachusetts School Building Authority (MSBA) with project administration by Stone Fleet, Inc. as the Owner's Project Manager and structural engineering by SMMA. The cost estimate is being prepared by Ellana, Inc., with design services by Tighe & Bond and code consulting by JS Consulting Engineers. The project is part of the Commonwealth's accelerated repair program targeting critical infrastructure improvements at educational facilities. The complete roofing system replacement is designed to achieve compliance with Massachusetts Building Code 10th Edition and the Massachusetts Stretch Energy Code, with minimum insulation R-value requirements and proper slope and drainage provisions. The electrical work includes disconnect switch installations, conduit extensions for HVAC equipment connections, new control circuits for BMS system integration, and provisions for future renewable energy systems. No specific contract award date, term length, or pricing information is provided in the drawing set, as these details would be contained in the separate bid documents and contract specifications.

View the file

Other files

File Type Posted
Bid Specifications for Gardner MS.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Pl ot te d

O n:

M ar

9, 6-

:2 1p m B y:

J

Ps ze ni cz ny La st S av ed

3/

9/

Ti gh e

B on d:

J

M

\M

0)

G ar dn er

M id dl e

S ch oo l\

D ra w in gs \A ut oC

A D

\S he et \M

-0

-G A R D

N

ER

C

O V

ER

.d w g

PREPARED BY:

PROJECT

LOCATION

GARDNER MIDDLE SCHOOL

MSBA ACCELERATED REPAIR PROGRAM

ROOF REPLACEMENT PROJECT

GARDNER, MASSACHUSETTS

SITE LOCATION MAP

SCALE: 1" = 2000'

COMPLETE SET 71 SHEETS

JOSEPH P. VIAMARI, PE, LEED AP MATTHEW P. WZOREK, PE

PROJECT TEAM:

OWNER

OWNER'S PROJECT MANAGER

STRUCTURAL ENGINEER

STONE FLEET, INC.

225 DYER STREET, 2ND FLOOR

PROVIDENCE, RI 02903

FUNDING

COST ESTIMATING

ELLANA, INC.

98 NORTH WASHINGTON STREET

SUITE 109

MASSACHUSETTS SCHOOL BUILDING

AUTHORITY

40 BROAD STREET, SUITE 500

BOSTON, MA 02109

BOSTON, MA 02114

SMMA

1000 MASSACHUSETTS AVENUE,

CAMBRIDGE, MA 02138

GARDNER PUBLIC SCHOOLS

160 ELM STREET

GARDNER, MA 01440

ENGINEER

TIGHE & BOND

DESIGNER SERVICES, INC.

53 SOUTHAMPTON ROAD

WESTFIELD, MA 01085

CODE CONSULTANT

JS CONSULTING ENGINEERS, PLLC

224 MAIN STREET, SUIT 2C

SALEM, NH 03079

ISSUED FOR BIDDING

MARCH 2026

N

G-002

LIST OF DRAWINGS

AS SHOWN

CHECKED BY:

DRAWN BY:

FILE:

APPROVED BY:

Gardner, Massachusetts

GARDNER

MIDDLE

SCHOOL ROOF

REPLACEMENT

PROJECT

City of Gardner

DATE:

PROJECT NO:

MARK DATE DESCRIPTION

A 6/20/2025 SCHEMATIC DESIGN SET

B 1/12/2026 60% DESIGN SET

C 3/9/2026 ISSUED FOR BIDDING

M1215-030-GARDNER- G-001.dwg

04/08/2025

M1215-030

SCALE:

Pl ot te d

O n:

M ar

9, 6- 1:

pm

B y:

J Ps ze ni cz ny

La st

S av ed

3/ 9/

Ti gh e

B on d:

J:

\M \M

0) G ar dn er M id dl e S ch oo l\

D ra w in gs \A ut oC

A D

\S he et \M

-0

-G A R D

N

ER

G

-0

.d w g

DESIGNED BY:

ISSUED FOR

BIDDING

S.OZTURK

M.WZOREK

J.VIAMARI

S.OZTURK

LIST OF DRAWINGS

SHEET NO. DRAWING NO. DRAWING TITLE

GENERAL

1 G-001 COVER SHEET

2 G-002 LIST OF DRAWINGS

3 G-003 EXISTING ROOF PHOTOGRAPHS

4 G-004 GENERAL NOTES

ARCHITECTURAL

5 AD-101 ROOF DEMOLITION PLAN

6 A-101 ROOF PLAN

7 A-102 ACCESSIBILITY IMPROVEMENTS PLAN

8 A-201A ALTERNATE NO.1: CEILING REPAIR PLAN

9 A-401 EXTERIOR ELEVATIONS - 1

10 A-402 EXTERIOR ELEVATIONS - 2

11 A-403 EXTERIOR ELEVATIONS - 3

12 A-404 EXTERIOR ELEVATIONS - 4

13 A-501 ROOF DETAILS - 1

14 A-502 ROOF DETAILS - 2

15 A-503 ROOF DETAILS - 3

16 A-504 ROOF DETAILS - 4

17 A-505 ROOF DETAILS - 5

18 A-506 ROOF DETAILS - 6

19 A-507 ROOF DETAILS - 7

20 A-508 ROOF DETAILS - 8

21 A-509 ROOF DETAILS - 9

22 A-510 ROOF DETAILS - 10

23 A-511 ROOF DETAILS - 11

24 A-512 ROOF DETAILS - 12

25 A-513 ROOF DETAILS - 13

26 A-514 ROOF DETAILS - 14

27 A-515 ROOF DETAILS - 15

28 A-516 ROOF DETAILS - 16

29 A-517 ROOF DETAILS - 17

30 A-518 ROOF DETAILS - 18

STRUCTURAL

31 S-100 ROOF ALLOWABLE SOLAR LOCATIONS

32 S-101 ROOF SNOW LOADS

PLUMBING

33 P-001 PLUMBING GENERAL NOTES, LEGEND, ABBREVIATIONS,

SCHEDULE AND DETAILS

34 P-101 PLUMBING ROOF PLAN

35 P-102 PLUMBING FIRST FLOOR PLAN

MECHANICAL

36 H-001 HVAC GENERAL NOTES, LEGEND, AND ABBREVIATIONS

37 H-101 HVAC ROOF PLAN

38 H-102 HVAC ROOF PLAN AREA C

39 H-103 HVAC ROOF PLAN AREA A

40 H-104 HVAC FLOOR PLANS - AREA A

41 H-105 HVAC FLOOR PLANS - AREA B

42 H-501 HVAC DETAILS

43 HD-101A HVAC DEMOLITION ROOF PLAN - ALTERNATE #1

44 H-101A HVAC ROOF PLAN - ALTERNATE #1

45 HD-103A ALTERNATE NO.1 : HVAC DEMOLITION FLOOR PLANS -

AREA A

46 HD-104A ALTERNATE NO.1 : HVAC DEMOLITION FLOOR PLANS -

AREA B

47 H-103A ALTERNATE NO. 1: HVAC FLOOR PLANS - AREA A

48 H-104A ALTERNATE NO.1 : HVAC FLOOR PLANS - AREA B

49 H-502A ALTERNATE NO.1 : HVAC CONTROL DIAGRAMS - 1

50 H-503A ALTERNATE NO.1 : HVAC CONTROL DIAGRAMS - 2

51 H-504A ALTERNATE NO.1: HVAC CONTROL DIAGRAMS - 3

52 H-601A HVAC SCHEDULES - ALTERNATE #1

ELECTRICAL

53 E-001 ELECTRICAL LEGEND

54 E-002 ELECTRICAL GENERAL NOTES AND ELECTRICAL

DETAILS

55 E-100 ELECTRICAL OVERALL ROOF PLAN

56 ED-101 ELECTRICAL ROOF PLAN - EXISTING CONDITIONS &

DEMOLITION

57 E-101 ELECTRICAL ROOF POWER PLAN - NEW WORK

58 E-102 ELECTRICAL PARTIAL ROOF POWER PLAN - NEW WORK

59 E-103 ELECTRICAL PARTIAL FLOOR PLANS - AREA C

60 E-104 PARTIAL FIRST FLOOR PLANS

61 ED-101A ALTERNATE NO. 1: ELECTRICAL ROOF PLAN - EXISTING

CONDITIONS & DEMOLITION

62 ED-102A ALTERNATE NO. 1: ELECTRICAL LOWER LEVEL FLOOR

PLAN - AREA A

63 ED-103A ALTERNATE NO. 1: ELECTRICAL FIRST FLOOR PLAN -

AREA A

64 ED-104A ALTERNATE NO. 1: ELECTRICAL LOWER LEVEL FLOOR

PLAN - AREA B

65 E-101A ALTERNATE NO.1: ELECTRICAL ROOF PLAN

66 E-102A ALTERNATE NO. 1: ELECTRICAL PARTIAL ROOF POWER

PLAN

67 E-103A ALTERNATE NO.1: ELECTRICAL PARTIAL FIRST FLOOR

PLAN - AREA C

68 E-104A ALTERNATE NO.1: ELECTRICAL LOWER LEVEL FLOOR

PLAN - AREA A

69 E-105A ALTERNATE NO. 1: ELECTRICAL PARTIAL LOWER LEVEL

PLAN - AREA B

70 E-200 BASE BID: ELECTRICAL SCHEDULES

71 E-200A ALTERNATE NO.1: ELECTRICAL SCHEDULES

NO SCALE

A

LEGEND:

PHOTOGRAPH LOCATIONA

EPDM ROOF - HIGH

NO SCALE

C

- NO SCALE

D

ROOF ACCESS HATCH

NO SCALE

F

- NO SCALE

G

ROOF TOP EQUIPMENT

NO SCALE

H

EPDM ROOF - HIGH

NO SCALE

I

BALLASTED ROOF SECTION

AND LOWER METAL ROOF

NO SCALE

B

G-003

EXISTING ROOF

PHOTOGRAPHS

AS SHOWN

N

GARDNER MIDDLE SCHOOL KEYPLAN

NO SCALE

CHECKED BY:

DRAWN BY:

FILE:

APPROVED BY:

Gardner, Massachusetts

GARDNER

MIDDLE

SCHOOL ROOF

REPLACEMENT

PROJECT

City of Gardner

DATE:

PROJECT NO:

MARK DATE DESCRIPTION

A 6/20/2025 SCHEMATIC DESIGN SET

B 1/12/2026 60% DESIGN SET

C 3/9/2026 ISSUED FOR BIDDING

M1215-030-GARDNER- G-001.dwg

04/08/2025

M1215-030

SCALE:

Pl ot te d

O n:

M ar

6, 6- 4:

pm

B y:

J Ps ze ni cz ny

La st

S av ed

3/ 4/

Ti gh e

B on d:

J:

\M \M

0) G ar dn er M id dl e S ch oo l\

D ra w in gs \A ut oC

A D

\S he et \M

-0

-G A R D

N

ER

G

-0

.d w g

DESIGNED BY:

ISSUED FOR

BIDDING

S.OZTURK

M.WZOREK

J.VIAMARI

S.OZTURK

METAL CANOPY ROOF

NO SCALE

K

NO SCALE

BALLASTED ROOF ANTENNA

NO SCALE

J

EPDM ROOF - MIDDLE

EPDM ROOF - LOW

NO SCALE

L

- NO SCALE

M

E

A B

C

D E F

G

H I J

K L

M

EPDM ROOF - HIGH EPDM ROOF - HIGH

EPDM ROOF - HIGH

EPDM ROOF - LOW

OVERALL EPDM ROOF AREAS -

DRONE FLIGHT VIEW

NO SCALE

N

- NO SCALE

O

- NO SCALE

P

LOWER METAL ROOF AREA -

DRONE FLIGHT VIEW

HIGHER METAL ROOF AREA -

DRONE FLIGHT VIEW

GENERAL NOTES

CONSTRUCTION NOTES

DEMOLITION NOTES

1. ALL MECHANICAL AND ELECTRICAL WORK SHALL BE COORDINATED WITH ROOFING CONTRACTOR, BUILDING OWNER, AND ALL TRADES INVOLVED.

2. SEE SHEET H-SHEETS FOR HVAC EQUIPMENT REQUIREMENTS.

3. FIELD VERIFY QUANTITY OF MECHANICAL EQUIPMENT, PIPING, AND SUPPORTS TO BE REMOVED.

4. PROVIDE TEMPORARY CAPS FOR ALL DUCTWORK. NO DUCTWORK SHALL REMAIN OPEN AT ANY TIME.

5. PERFORM ALL REMOVAL AND REINSTALLATION OF ALL EQUIPMENT AND DUCTWORK. REINSTALLATION SHALL BE PERFORMED AFTER INSTALLATION OF NEW

ROOFING AND FLASHING BY ROOFING CONTRACTOR.

6. PRIOR TO UNIT REMOVAL, PERFORM PRE-BALANCE OF ALL AIR HANDLERS AND EXHAUST FANS SCHEDULED TO REMAIN. RECORD AIRFLOWS FOR FINAL BALANCING

EFFORTS AND PROVIDE INFORMATION TO THE ENGINEER.

7. DURING DEMOLITION, CONTROL WIRING IS TO BE DISCONNECTED AND PROTECTED FOR FUTURE USE/RE-CONNECTION. EXTEND ALL WIRING AND CONDUIT AS NECESSARY FOR CURB REPLACEMENT. RECONNECT ALL CONTROL WIRING FOR PROPER OPERATION.

8. REMOVE AND DISPOSE OF ALL EXISTING CURBS. NEW CURBS SHALL BE RAISED TO PROVIDE A MINIMUM OF 12" OF CLEARANCE FROM ADJACENT ROOFING. AT

ALL ROOF CURBS INSTALL NEW CRICKETS TO ENSURE PROPER DRAINAGE.

9. NEW SLEEPERS ARE TO BE PROVIDED BY THE ROOFING CONTRACTOR.

10. ELECTRICAL CONTRACTOR SHALL DISCONNECT AND MAKE SAFE THE EXISTING MECHANICAL EQUIPMENT FOR REMOVAL BY HVAC CONTRACTOR. THE EXISTING FEEDER SHALL BE DE-ENEREGIZED AND LOCKED OUT FOR THE DURATION OF THE NEW ROOF WORK. THE ELECTRICAL CONTRACTOR SHALL RECONNECT FEEDER TO EXISTING MECHANICAL EQUIPMENT UPON THE RE-INSTALLATION BY HVAC CONTRACTOR. ELECTRICAL CONTRACTOR SHALL EXTEND CONDUITS AND WIRING

AS REQUIRED.

11. ALL CONDUIT RUNS ACROSS ROOF SHALL BE REMOVED AND REINSTALLED UPON COMPLETION OF ROOF UNLESS CONDUITS AND WIRE HAVE BEEN PREVIOUSLY

ABANDONED IN WHICH CASE THEY SHALL BE REMOVED AND DISPOSED OF.

MECHANICAL AND ELECTRICAL GENERAL NOTES

1. COORDINATE PROPOSED METHODS AND OPERATIONS OF DEMOLITION WITH OWNER'S DESIGNATED REPRESENTATIVE AND SCHOOL STAFF PRIOR TO START OF DEMOLITION WORK. INCLUDE IN SCHEDULE COORDINATION FOR SHUT-OFF, CAPPING AND CONTINUATION OF UTILITY SERVICES IF REQUIRED.

2. COORDINATE INTERRUPTIONS IN DAILY OPERATIONS IN ADVANCE WITH OWNER'S REPRESENTATIVE. THIS SHALL INCLUDE SERVICE INTERRUPTIONS AND CONNECTIONS, RELOCATION OF OCCUPANTS, REMOVAL OF EQUIPMENT, AND SHIFTS IN LOCATION OF WORK.

3. CONDUCT DEMOLITION AND DEBRIS REMOVAL IN A SAFE MANNER TO MINIMIZE INTERFERENCE WITH CORRIDORS, HALLS, STAIRS, AND OTHER ADJACENT FACILITIES AND TO AVOID DAMAGE TO SAME. DO NOT CLOSE OR OBSTRUCT TRAFFIC WAYS WITHOUT PRIOR APPROVAL.

4. PROVIDE TEMPORARY SHORING DURING THE COURSE OF DEMOLITION WORK TO MAINTAIN STABILITY AND PREVENT DAMAGE TO EXISTING STRUCTURE. ERECT TEMPORARY ENCLOSURES AROUND ALL EXTERIOR OPENINGS CREATED IN THE BUILDING. THE BUILDING SHALL BE LEFT WEATHER TIGHT AND SECURE AT THE END OF

EACH WORK DAY.

5. PROVIDE TEMPORARY DUST ENCLOSURES AROUND ALL AREAS OF WORK. PREVENT DUST, AND DEBRIS FROM REACHING ADJACENT AREAS OF BUILDING.

6. UNLESS OTHERWISE INDICATED ON THE DRAWINGS ALL PORTIONS OF THE EXISTING BUILDING, INCLUDING FINISHES DISTURBED BY DEMOLITION OF EXISTING CONSTRUCTION AND/OR INSTALLATION OF NEW CONSTRUCTION, SHALL BE REPAIRED AND RESTORED TO ORIGINAL OR BETTER CONDITION.

7. REMOVE AND DISPOSE OF THE EXISTING SINGLE-PLY ROOF SYSTEM DOWN TO THE ORIGINAL DECK INCLUDING BALLAST, MEMBRANE, FIBERBOARD AND INSULATION AS

SHOWN.

8. REMOVE AND DISPOSE OF THE EXISTING METAL ROOF SYSTEM DOWN TO THE ORIGINAL DECK INCLUDING METAL PANELS, FIBERBOARD, AND INSULATION AS SHOWN.

9. ALL EXISTING ROOF EDGE BLOCKING TO BE REMOVED AND REPLACED AS SHOWN ON DETAILS.

10. REMOVE AND DISPOSE OF ALL EQUIPMENT CURBS.

11. REMOVE ONLY AS MUCH ROOF AREA AS CAN BE REPLACED OR PROTECTED PRIOR TO END OF EACH WORK DAY.

1. COMPLY WITH THE MASSACHUSETTS BUILDING CODE 780 CMR TENTH EDITION CHAPTER 34, MASSACHUSETTS STRETCH ENERGY CODE 225 CMR 23.00, AND ANY OTHER CODES AND REGULATIONS OF AUTHORITIES HAVING JURISDICTION. SUBMIT COPIES OF ANY INSPECTION REPORTS AND OTHER SIMILAR COMMUNICATIONS

TO OWNER AND DESIGNER.

2. EXISTING CONDITIONS WERE BASED ON DRAWINGS TITLED "GARDNER MIDDLE SCHOOL", PREPARED BY A. ANTHONY TAPPE & ASSOCIATES, INC., DATED OCTOBER

1995, AND FIELD RECONNAISSANCE.

3. BOLD TEXT AND LINES INDICATE PROPOSED WORK. LIGHT TEXT AND LINES INDICATE APPROXIMATE EXISTING CONDITIONS.

4. FIELD VERIFY ALL EXISTING CONDITIONS INCLUDING DIMENSIONS, STRUCTURES, AND UTILITIES. REPORT ALL DISCREPANCIES WITH THE DRAWINGS TO THE

DESIGNER.

5. THE DRAWINGS HAVE BEEN COMPILED FROM THE BEST AVAILABLE INFORMATION AND ARE NOT INTENDED TO LIMIT THE SCOPE OF WORK. THE CONTRACTOR MAY UNCOVER HIDDEN CONDITIONS NOT SHOWN IN THE CONTRACT SET. ANY DEVIATIONS SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE DESIGNER.

6. PERFORM ALL WORK DESCRIBED IN THE DRAWINGS AND SPECIFICATIONS AND PROVIDE ALL ITEMS REQUIRED FOR A COMPLETE FUNCTIONING SYSTEM, INCLUDING

APPROPRIATE BLOCKING AND FLASHING.

7. WHERE REMOVAL OF EXISTING CONSTRUCTION IS REQUIRED FOR PERFORMANCE OF ANY WORK UNDER THIS CONTRACT, REMOVAL AND REINSTALLATION SHALL BE ACCOMPLISHED UNDER THE BASE CONTRACT WHETHER SPECIFICALLY SHOWN OR NOT, INCLUDING RESTORATION OF UTILITIES AND ANY TEMPORARY SHORING OF

STRUCTURAL COMPONENTS.

8. ALL METAL AND MEMBRANE FLASHING TO BE LAPPED POSITIVELY TO DRAIN TO THE BUILDING EXTERIOR.

9. PROVIDE SEPARATION BETWEEN DISSIMILAR METALS AND MATERIALS TO PREVENT GALVANIC ACTION.

10. CONTRACTOR WILL NOT HAVE ACCESS TO BATHROOMS OR INTERIOR FACILITIES.

11. PROVIDE SECURE WORK AREA. NO CONSTRUCTION TRAFFIC SHALL INTERFERE WITH TRAFFIC ENTERING AND EXITING THE FACILITY. A CONSTRUCTION FENCE MAY BE

CONSTRUCTED FOR THE MATERIAL STAGING AREA AS NEEDED.

12. THE EXISTING ROOF DECK IS NOT ADEQUATELY SLOPED AND WILL REQUIRE TAPERED INSULATION FOR DRAINAGE AS SHOWN ON THESE PLANS.

13. INSTALL RIGID INSULATION AS REQUIRED TO PROVIDE A MINIMUM R-VALUE OF 30 AND A MINIMUM THICKNESS OF 6". INSULATION THICKNESS PROVIDED IS THE MINIMUM THICKNESS OF INSULATION ABOVE THE ROOF DECK WITH THE EXCEPTION OF ROOF DRAIN SUMP AREAS.

14. ENSURE THAT THE FINAL ROOF SLOPE IS A MINIMUM OF 1/4" PER FOOT TO DRAINS UNLESS NOTED OTHERWISE.

15. SUPPLY ELECTRICITY AND WATER. OWNER WILL NOT PROVIDE THESE UTILITIES.

16. HEIGHT OF MECHANICAL EQUIPMENT CURBS SHALL PROVIDE 12-INCH MINIMUM CLEARANCE ABOVE NEW ROOF SURFACE.

17. PROVIDE NEW TAPERED CRICKETS AT THE HIGH POINT SIDE OF ALL ROOF PENETRATIONS AND MECHANICAL EQUIPMENT LARGER THAN ONE SQUARE FOOT TO

PROMOTE DRAINAGE.

18. CONFIRM HEIGHTS OF ALL NEW INSULATION AT EXISTING WALL TO ROOF FLASHING PRIOR TO MASONRY REMOVAL REQUIRED TO ACCOMMODATE NEW THRU WALL

FLASHING. MINIMUM FLASHING HEIGHT SHALL BE 8" ABOVE FINISHED ROOF SURFACE.

19. CONFIRM HEIGHTS OF ALL NEW BLOCKING AT ROOF EDGES TO ACCOMMODATE HEIGHT OF NEW INSULATION.

20. RESTORE ALL LANDSCAPING AND SITE FEATURES TO EXISTING OR BETTER CONDITION. ALL DAMAGE TO LANDSCAPING OR SITE FEATURES WILL BE THE

RESPONSIBILITY OF THE CONTRACTOR.

21. ALL FASTENERS USED DURING CONSTRUCTION SHALL BE SPECIFIED FOR COMPATIBILITY WITH PRESSURE-TREATED WOOD.

1. ALL PLUMBING WORK SHALL BE COORDINATED WITH ROOFING CONTRACTOR, BUILDING OWNER, AND ALL TRADES INVOLVED.

2. SEE SHEET P-101 FOR PLUMBING REQUIREMENTS.

3. FIELD VERIFY QUANTITY OF ROOF DRAINS, PIPING, AND SUPPORTS TO BE REMOVED.

4. PLUMBING CONTRACTOR TO PERFORM ALL REMOVAL AND INSTALLATION OF ALL ROOF DRAINS AND PIPING. INSTALLATION FOR ROOF DRAINS SHALL BE

PERFORMED BEFORE INSTALLATION OF NEW ROOFING AND FLASHING BY ROOFING CONTRACTOR.

5. EXTEND ALL EXISTING VENT PIPES TO TERMINATE 18"-24" ABOVE NEW ROOF.

PLUMBING GENERAL NOTES

G-004

S.OZTURK

M.WZOREK

J.VIAMARI

AS SHOWN

ABBREVIATIONS

CL CENTERLINE

DIA DIAMETER

EF EXHAUST FAN

EL/ELEV ELEVATION

ELEC ELECTRIC

EPDM ETHYLENE PROPYLENE DIENE MONOMER

FIN FINISH

FLR FLOOR

FT FOOT/FEET

GA GAUGE

GC GENERAL CONTRACTOR

HDG HOT DIP GALVANIZED

HVAC HEATING, VENTILATION, AND AIR CONDITIONING

MAX MAXIMUM

MIN MINIMUM

OC ON CENTER

PT PRESSURE TREATED

RF ROOF FAN

SS STAINLESS STEEL

TPO THERMOPLASTIC POLYOLEFIN

TYP TYPICAL

CHECKED BY:

DRAWN BY:

FILE:

APPROVED BY:

Gardner, Massachusetts

GARDNER

MIDDLE

SCHOOL ROOF

REPLACEMENT

PROJECT

City of Gardner

DATE:

PROJECT NO:

MARK DATE DESCRIPTION

A 6/20/2025 SCHEMATIC DESIGN SET

B 1/12/2026 60% DESIGN SET

C 3/9/2026 ISSUED FOR BIDDING

M1215-030-GARDNER- G-002.dwg

04/08/2025

M1215-030

SCALE:

Pl ot te d

O n:

M ar

6, 6- 4:

pm

B y:

J Ps ze ni cz ny

La st

S av ed

3/ 4/

Ti gh e

B on d:

J:

\M \M

0) G ar dn er M id dl e S ch oo l\

D ra w in gs \A ut oC

A D

\S he et \M

-0

-G A R D

N

ER

G

-0

.d w g

DESIGNED BY:

ISSUED FOR

BIDDING

S.OZTURK

1. BUILDING/PROJECT DESCRIPTION:

REMOVAL AND REPLACEMENT OF EXISTING ROOFING SYSTEM, REMOVAL AND RESETTING OF EXISTING HVAC EQUIPMENT, ROOF DRAIN REPLACEMENT, ACCESSIBILITY IMPROVEMENTS .

2. APPLICABLE GOVERNING CODES:

BUILDING: 780 CMR MASSACHUSETTS STATE BUILDING CODE 10TH EDITION, MASSACHUSETTS EXISTING BUILDING CODE 780 CMR 34

PLUMBING: MASS STATE PLUMBING CODE, 248 CMR

MECHANICAL: INTERNATIONAL MECHANICAL CODE (IMC) 2021; 780 CMR; 248 CMR

ELECTRICAL: MASS STATE ELECTRICAL CODE, 527 CMR

ENERGY: MASS ENERGY EFFICIENCY CODE, 780 CMR; MASSACHUSETTS STRETCH ENERGY CODE, 225 CMR 23

ACCESSIBILITY: 521 CMR ARCHITECTURAL ACCESS BOARD REGULATIONS

3. USE AND OCCUPANCY:

GROUP E, EDUCATIONAL

4. CONSTRUCTION TYPE:

TYPE IIB - UNPROTECTED NONCOMBUSTIBLE

BUILDING CODE ANALYSIS

1. ANY DAMAGED METAL DECK DISCOVERED DURING DEMOLITION SHALL BE BROUGHT TO THE

ATTENTION OF THE ENGINEER.

2. METAL DECK PANELS REQUIRING REPAIR SHALL BE REPLACED IN ITS ENTIRETY. PANEL REPLACEMENT

LOCATIONS SHALL BE CONFIRMED BY THE ENGINEER OF RECORD.

3. METAL DECK PANELS SHALL BE INSTALLED TO MATCH EXISTING PANEL LAYOUT AND SECUREMENT

PATTERN AS FOLLOWS:

A. PANELS ENDS AND END LAPS: 5/8” DIA. PUDDLE WELD AT EACH RIB

B. INTERMEDIATE SUPPORTS: 5/8” DIA. PUDDLE WELD AT EACH RIB

C. LONGITUDINAL EDGES OF MARGINAL SUPPORTS: 5/8” DIA. PUDDLE WELD AT 12” O.C.

MAXIMUM.

D. SIDE LAPS FOR ADJACENT UNITS: #12 SCREWS AT 30” O.C. MAXIMUM (BUTTON PUNCH AT

30” O.C. MAXIMUM FOR CELLULAR ACOUSTIC METAL DECK)

STRUCTURAL GENERAL NOTES

DETAIL 1

-3" = 1'-0"

TYPICAL EXISTING ROOF SECTION

REMOVE AND DISPOSE OF EXISTING

ROOFING SYSTEM INCLUDING MEMBRANE,

FIBERBOARD, INSULATION, VAPOR BARRIER

REMOVE AND DISPOSE OF EXISTING

ROOFING SYSTEM INCLUDING

MEMBRANE, FIBERBOARD, INSULATION,

AND VAPOR BARRIER

REMOVE AND DISPOSE OF EXISTING

METAL ROOFING SYSTEM INCLUDING METAL

PANELS, FIBERBOARD, INSULATION, FELT, AND

ICE AND WATER SHIELD

REMOVE AND DISPOSE OF EXISTING

ROOFING SYSTEM INCLUDING MEMBRANE,

FIBERBOARD, INSULATION, VAPOR BARRIER,

AND GRAVEL BALLAST

REMOVE AND DISPOSE OF EXISTING

METAL ROOFING SYSTEM INCLUDING METAL

PANELS, FIBERBOARD, INSULATION, FELT, AND

ICE AND WATER SHIELD

REMOVE AND DISPOSE OF EXISTING

ROOFING SYSTEM INCLUDING

MEMBRANE, FIBERBOARD, INSULATION,

AND VAPOR BARRIER

REMOVE AND DISPOSE OF EXISTING

ROOFING SYSTEM INCLUDING MEMBRANE,

FIBERBOARD, INSULATION, VAPOR BARRIER

REMOVE AND DISPOSE OF EXISTING

ROOFING SYSTEM INCLUDING MEMBRANE,

FIBERBOARD, INSULATION, VAPOR BARRIER,

AND GRAVEL BALLAST

CHECKED BY:

DRAWN BY:

FILE:

APPROVED BY:

Gardner, Massachusetts

GARDNER

MIDDLE

SCHOOL ROOF

REPLACEMENT

PROJECT

City of Gardner

DATE:

PROJECT NO:

MARK DATE DESCRIPTION

A 6/20/2025 SCHEMATIC DESIGN SET

B 1/12/2026 60% DESIGN SET

C 3/9/2026 ISSUED FOR BIDDING

M1215-030-GARDNER - AD-101.dwg

04/08/2025

M1215-030

SCALE:

Pl ot te d

O n:

M ar

6, 6- 4:

pm

B y:

J Ps ze ni cz ny

La st

S av ed

3/ 6/

Ti gh e

B on d:

J:

\M \M

0) G ar dn er M id dl e S ch oo l\

D ra w in gs \A ut oC

A D

\S he et \M

-0

-G A R D

N

ER

A

D -1

.d w g

DESIGNED BY:

ISSUED FOR

BIDDING

S.OZTURK

S.OZTURK

M.WZOREK

J.VIAMARI

AD-101

ROOF DEMOLITION PLAN

AS SHOWN0 8' 16' 32'

SCALE: 1/16"=1'-0"

N

LEGEND

ROOF DRAIN

EXISTING VENT PIPE PENETRATION

EXISTING ROOF SLOPE LINE

EXISTING INSULATION THICKNESS TEST CUT

ITEM TO BE REMOVED/DEMOLISHED

EXISTING EXPANSION JOINT

ROOF SLOPE DIRECTION

ACCESS HATCH

ROOF LEVEL #1. APPROX ELEV. 16'-0" ABOVE

GRADE. REMOVE AND DISPOSE OF EXISTING EPDM

ROOFING SYSTEM. SEE DETAIL

ROOF DRAINS: SEE SHEET

P-101 FOR DEMOLITION

DETAILS (TYP)

REMOVE AND DISPOSE OF

HVAC EQUIPMENT CURB AND

FLASHING. SEE SHEETS A-511

AND H-101 FOR DETAILS (TYP)

REMOVE AND DISPOSE

OF ACCESS HATCH AND

LADDER. PATCH HOLES LEFT IN

MASONRY BY ACCESS LADDER SCREWS

AS NEEDED

REMOVE AND DISPOSE

OF VENT FLASHING (TYP)

ROOF LEVEL #5. RIDGE ELEV. VARIES.

REMOVE AND DISPOSE OF EXISTING

METAL ROOFING SYSTEM. INCLUDING

GUTTERS AND DOWNSPOUTS.

SEE DETAIL

REMOVE AND DISPOSE

OF EXISTING EPDM

CANOPY ROOFING

SYSTEM. SEE DETAIL

ROOF LEVEL #1. REMOVE AND

DISPOSE OF EXISTING EPDM

ROOFING SYSTEM.

SEE DETAIL

ROOF LEVEL #2. APPROX ELEV. 33'-0" ABOVE GRADE.

REMOVE AND DISPOSE OF EXISTING EPDM ROOFING

SYSTEM. SEE DETAIL

ROOF LEVEL #3. APPROX ELEV. 28'-0" ABOVE GRADE.

REMOVE AND DISPOSE OF EXISTING EPDM ROOFING

SYSTEM AND STONE BALLAST. SEE DETAIL

REMOVE AND

DISPOSE OF

LADDER

REMOVE AND DISPOSE

OF WALKPADS (TYP)

REMOVE AND DISPOSE

OF VENT FLASHING (TYP).

REMOVE AND DISPOSE OF

EXISTING METAL ROOFING

OVER DORMERS, PANELS

AND FLASHING (TYP)

ROOF LEVEL #3. REMOVE AND DISPOSE OF

EXISTING EPDM ROOFING SYSTEM. SEE DETAIL

ROOF LEVEL #4. APPROX RIDGE ELEV. 52'-8"

ABOVE GRADE. REMOVE AND DISPOSE OF

EXISTING METAL ROOFING SYSTEM

INCLUDING GUTTERS AND DOWNSPOUTS.

SEE DETAIL ROOF DRAINS: SEE SHEET

P-101 FOR DEMOLITION

DETAILS (TYP)

WALL MOUNTED CONDENSING UNIT. SEE

SHEET H-101 FOR DETAILS (TYP)

REMOVE AND DISPOSE OF EXISTING

EXPANSION JOINT

REMOVE AND DISPOSE OF

HVAC EQUIPMENT CURB AND

FLASHING. SEE SHEETS A-511

AND H-501 FOR DETAILS (TYP)

A-503

DETAIL 2

-1 1/2" = 1'-0"

TYPICAL EXISTING METAL ROOF SYSTEM

DETAIL 1

-1 1/2" = 1'-0"

TYPICAL EXISTING EPDM ROOF SYSTEM

DETAIL 3

-1 1/2" = 1'-0"

TYPICAL EXISTING CANOPY ROOF SYSTEM

A-501

A-501

A-502

A-502

HIGH

LOW

A-501

AD-101

AD-101

AD-101

AD-101

AD-101

AD-101

AD-101

A-505

A-505

A-505

A-502

A-505

A-505

A-502

LOW

A-502

HIGH

A-505

A-507

A-507

A-507

A-507

REMOVE AND DISPOSE

OF EXISTING ANTENNA,

CABLES, AND CEMENT BLOCKS

A-504

LOW

REMOVE AND

DISPOSE OF

EXISTING

EXPANSION JOINT

A-506

A-506

REMOVE AND DISPOSE OF EXISTING

PERFORATED PIPE

A-503

A-502

HIGH

A-502

LOW

A-504

A-505

A-505

HIGH

A-511

A-505

HIGHLOW

2 12'X1'

PENETRATION

THROUGH EXISTING

ROOF FOR NEW

GOOSENECK.

SEE SHEET H-101

GENERAL NOTES:

1. ROOFING CONTRACTOR SHALL REMOVE AND DISPOSE OF ALL EXISTING HVAC

EQUIPMENT CURBS.

2. SEE SHEET H-101 FOR HVAC EQUIPMENT REQUIREMENTS.

3. EXISTING METAL ROOF DECKS ARE SLOPED AT 4" PER FOOT UNLESS OTHERWISE

NOTED.

4. EXISTING EPDM ROOF SECTIONS HAVE TAPERED INSULATION SLOPED AT

APPROXIMATELY 1/8" PER FOOT.

5. CONTRACTOR TO VERIFY CONDITION OF METAL DECKING. SEE A-515 FOR REPAIR

AND REINFORCEMENT OF METAL DECKING DETAILS.

EXISTING GRAVITY VENTILATOR

EXISTING EXHAUST FAN

A-512

A-512

A-510

A-510

DETAIL 4

-1 1/2" = 1'-0"

TYPICAL EXISTING BALLASTED ROOF SYSTEM

A-512

A-512

A-514

A-510

AD-101

LIMIT OF WORK

REMOVE AND DISPOSE OF EXISTING

DOWNSPOUTS (TYP OF 26)

REMOVE AND DISPOSE OF EXISTING

DOWNSPOUTS (TYP OF 26)

REMOVE AND

DISPOSE

OF EXISTING

DOWNSPOUTS

(TYP OF 26)

A-512

A-501

A-515

A-505

HIGH

A-516 LOW

A-502

HIGH

A-516

LOW

A-517

LOW

A-505

HIGH

A-503

HIGH

A-517

LOW

A-517 LOW

A-507LOW 1

A-508 LOW

A-508

REMOVE AND DISPOSE OF EXISTING METAL ROOFING

OVER DORMERS, PANELS AND FLASHING (TYP). SEE

SHEET A-506 FOR BASE AND EDGE DETAILS

A-515

A-515

CUT, REMOVE, AND DISPOSE OF

CMU BLOCK AND STONE

COPING ABOVE SCUPPERS (TYP

OF 5). SEE SHEET A-518 FOR

DETAILS

DETAIL 1

-3" = 1'-0"

TYPICAL EXISTING ROOF SECTION

REMOVE AND DISPOSE OF EXISTING

ROOFING SYSTEM INCLUDING MEMBRANE,

FIBERBOARD, INSULATION, VAPOR BARRIER

REMOVE AND DISPOSE OF EXISTING

ROOFING SYSTEM INCLUDING

MEMBRANE, FIBERBOARD, INSULATION,

AND VAPOR BARRIER

REMOVE AND DISPOSE OF EXISTING

METAL ROOFING SYSTEM INCLUDING

FIBERBOARD, INSULATION, ICE AND

WATER SHIELD

UNDERLAYMENT (TYP)

RIGID

INSULATION (TYP)

METAL ROOF PANEL (TYP)

COVERBOARD (TYP)

AIR/VAPOR BARRIER (TYP)

TAPERED RIGID INSULATION (TYP)

COVER BOARD (TYP)

AIR/VAPOR

BARRIER (TYP)

RIGID

INSULATION (TYP)

SUBSTRATE BOARD (TYP)

EPDM ROOFING MEMBRANE (TYP)

SUBSTRATE

BOARD (TYP)

AIR/VAPOR BARRIER (TYP)

3" RIGID INSULATION

COVERBOARD

EPDM ROOFING MEMBRANE

16"

9"

14"

10"

14"

11"

15.5"

14"

10.5"

8"

8"

8"

8" 9"

9"

REMOVE AND DISPOSE OF EXISTING

ROOFING SYSTEM INCLUDING MEMBRANE,

FIBERBOARD, INSULATION, VAPOR BARRIER, AND

GRAVEL BALLAST

PHOTOVOLTAIC READY ZONE SOLAR

INSTALLATION PERMITTED UP TO 3 PSF

SOLAR WEIGHT MAXIMUM

APPROXIMATE AREA = 4,300 SF

PV INVERTER

LOCATION

2-2" CONDUITS

MOUNTED ON RUBBER

SLEEPERS. SEE E-100

FOR DETAILS

SUBSTRATE BOARD (TYP)

UNDERLAYMENT (TYP)

RIGID

INSULATION (TYP)

METAL ROOF PANEL (TYP)

COVERBOARD (TYP)

AIR/VAPOR BARRIER (TYP)

SUBSTRATE BOARD (TYP)

SUBSTRATE

BOARD (TYP)

AIR/VAPOR BARRIER (TYP)

3" RIGID INSULATION

COVERBOARD

EPDM ROOFING MEMBRANE

TAPERED RIGID INSULATION (TYP)

COVER BOARD (TYP)

AIR/VAPOR

BARRIER (TYP)

RIGID

INSULATION (TYP)

SUBSTRATE BOARD (TYP)

EPDM ROOFING MEMBRANE (TYP)

CHECKED BY:

DRAWN BY:

FILE:

APPROVED BY:

Gardner, Massachusetts

GARDNER

MIDDLE

SCHOOL ROOF

REPLACEMENT

PROJECT

City of Gardner

DATE:

PROJECT NO:

MARK DATE DESCRIPTION

A 6/20/2025 SCHEMATIC DESIGN SET

B 1/12/2026 60% DESIGN SET

C 3/9/2026 ISSUED FOR BIDDING

M1215-030-GARDNER - A-101.dwg

04/08/2025

M1215-030

SCALE:

Pl ot te d

O n:

M ar

6, 6- 4:

pm

B y:

J Ps ze ni cz ny

La st

S av ed

3/ 6/

Ti gh e

B on d:

J:

\M \M

0) G ar dn er M id dl e S ch oo l\

D ra w in gs \A ut oC

A D

\S he et \M

-0

-G A R D

N

ER

A

-1

.d w g

DESIGNED BY:

ISSUED FOR

BIDDING

S.OZTURK

S.OZTURK

M.WZOREK

J.VIAMARI

A-101

ROOF PLAN

AS SHOWN0 8' 16' 32'

SCALE: 1/16"=1'-0"

N

ROOF LEVEL #1. APPROX

ELEV. 16'-0"

ROOF DRAIN. SEE

SHEET P-101 FOR

DETAILS (TYP)

HVAC EQUIPMENT CURB AND

FLASHING. SEE SHEETS

A-511 AND H-101 FOR

DETAILS (TYP)

ACCESS HATCH AND

LADDER VENT STACK PENETRATION

FLASHING (TYP)

ROOF LEVEL #5. RIDGE

ELEV. VARIES

EPDM CANOPY

ROOFING SYSTEM

ROOF LEVEL #1. APPROX

ELEV. 16'-0"

ROOF LEVEL #2. APPROX

ELEV. 33'-0"

ROOF LEVEL #3. APPROX

ELEV. 28'-0"

LADDER. SEE

SHEET A-509

WALKPAD (TYP)

VENT STACK PENETRATION

FLASHING (TYP).

METAL ROOFING OVER

DORMERS, PANELS AND

FLASHING (TYP)

ROOF LEVEL #3. APPROX

ELEV. 28'-0"

ROOF LEVEL #4. APPROX

RIDGE ELEV. 52'-8" ROOF DRAIN. SEE SHEET P-101

FOR DETAILS (TYP)

WALL MOUNTED CONDENSING UNIT. SEE

SHEET H-101 FOR DETAILS (TYP)

ROOF EXPANSION JOINT

A-101

HVAC EQUIPMENT METAL

FLASHING. SEE SHEETS H-101

AND A-512 FOR DETAILS

A-503

DETAIL 2

-1 1/2" = 1'-0"

TYPICAL METAL ROOF SYSTEM

DETAIL 1

-1 1/2" = 1'-0"

TYPICAL EPDM ROOF SYSTEM

DETAIL 3

-1 1/2" = 1'-0"

TYPICAL CANOPY ROOF SYSTEM

A-501

A-501

A-502

A-502

HIGH

LOW

A-501

A-101

A-101

A-101

A-101

A-101

A-101

A-101

A-505

A-505

A-505

A-502

A-505

A-505

A-502

LOW

A-502

HIGH

A-505

A-507

A-507

A-507

A-507

A-504

LOW

CANOPY

EXPANSION

JOINT

A-506

A-506

A-503

A-502

HIGH

A-502

LOW

A-504

A-505

A-505

HIGH

A-505

HIGHLOW

ROOF DRAIN

VENT PIPE PENETRATION

GENERAL NOTES:

1. INSTALL NEW CURBING FOR ALL HVAC EQUIPMENT. NEW CURBS MUST BE MINIMUM 12" ABOVE NEW ROOFING.

COORDINATE WITH MECHANICAL CONTRACTOR FOR THE INSTALLATION OF MECHANICAL EQUIPMENT INSTALL NEW

CRICKETS TO ENSURE PROPER DRAINAGE AT ALL ROOF CURBS.

2. ADJUST ELEVATION OF ROOF EDGES TO MATCH THE MAXIMUM INSULATION THICKNESS AT EACH ROOF DECK ELEVATION

TO PROVIDE A LEVEL ROOF PERIMETER.

3. TAPERED INSULATION SHALL BE INSTALLED TO ACHIEVE FINAL SLOPE OF 1/4" PER FOOT MINIMUM UNLESS NOTED

OTHERWISE. CRICKETS TO BE 12" PER FOOT MINIMUM SLOPE.

4. NUMBER OF ROWS, CLAMP SPACING, AND TORQUE SETTINGS OF SNOW RETENTION SYSTEM SHALL BE PER

MANUFACTURER'S RECOMMENDATION BASED ON SNOW LOAD CALCULATIONS.

ROOF SLOPE LINE

BALLASTED GUARDRAIL FOR FALL PROTECTION

APPROXIMATE INSULATION THICKNESS

WALKPAD

ROOF SLOPE DIRECTION

LEGEND

PROPOSED ACCESS HATCH

PROPOSED CRICKETS

42" TALL SCHEDULE 40

GALVANIZED STEEL

BALLASTED GUARDRAIL

VERTICAL POSTS 4' O.C. (TYP).

CONTINUOUS SNOW RETENTION

SYSTEM (TYP). SEE SHEET

A-513 FOR DETAILS.

CONTINUOUS

SNOW RETENTION

SYSTEM (TYP).

SEE SHEET A-513

FOR DETAILS

CONTINUOUS SNOW RETENTION

SYSTEM (TYP). SEE SHEET

A-513 FOR DETAILS

GRAVITY VENTILATOR

EXHAUST FAN

A-512

A-512

A-510

A-512

A-512

A-514

A-516

A-510

LOW

A-508

2 12'X1' GOOSENECK

VENT PIPE

PENETRATION. SEE

SHEET H-101

A-510

METAL ROOFING OVER DORMERS, PANELS

AND FLASHING (TYP). SEE SHEET A-506

FOR EDGE AND BASE DETAILS

A-511

LIMIT OF WORK

A-515

A-515

A-515

SCUPPERS TO BE RAISED AS

NEEDED TO ACCOMMODATE

NEW INSULATION THICKNESS

(TYP OF 5). SEE SHEET A-518

FOR DETAILS.

RUBBER SPLASH BLOCK (TYP OF 4)

ALUMINUM ROOF LEADER SIZED TO MATCH EXISTING (TYP OF 26)

A-503

HIGH

A-502

HIGH

A-516

LOW

ROOF EDGE AT VERTICAL

WALL CORNER A-514

ROOF EDGE AT VERTICAL

WALL CORNER A-514

ROOF EDGE AT VERTICAL

WALL CORNER A-514

ROOF EDGE AT VERTICAL

WALL CORNERA-514

A-517

LOW

A-505

HIGH

A-501

A-517

LOW

A-517LOW

A-508 LOW

A-507LOW

A-515

INTAKE DUCTWORK SUPPORT.

SEE H-101 FOR DETAILS.

HIGH

ALUMINUM ROOF LEADER SIZED

TO MATCH EXISTING (TYP OF 26)

VESTIBULE DRAINAGE

SCUPPER. SEE SHEET

A-515 FOR DETAILS

CONDENSING UNIT

A-508

6" MAX.

9" M

IN

8"

M

IN

K N

EE

C

LE

A R A N

C E

M A X

TO

P

O F

S

PO

U T

2"

16"

3 16

ADJUSTABLE VINYL

CUSHIONS

RECESSED GRILLE FLOOR

SHALL ALIGN WITH ADJACENT

FLOOR AND THRESHOLD

CHECKED BY:

DRAWN BY:

FILE:

APPROVED BY:

Gardner, Massachusetts

GARDNER

MIDDLE

SCHOOL ROOF

REPLACEMENT

PROJECT

City of Gardner

DATE:

PROJECT NO:

MARK DATE DESCRIPTION

A 6/20/2025 SCHEMATIC DESIGN SET

B 1/12/2026 60% DESIGN SET

C 3/9/2026 ISSUED FOR BIDDING

M1215-030-GARDNER - A-101.dwg

04/08/2025

M1215-030

SCALE:

Pl ot te d

O n:

M ar

6, 6- 4:

pm

B y:

J Ps ze ni cz ny

La st

S av ed

3/ 6/

Ti gh e

B on d:

J:

\M \M

0) G ar dn er M id dl e S ch oo l\

D ra w in gs \A ut oC

A D

\S he et \M

-0

-G A R D

N

ER

A

-1

.d w g

DESIGNED BY:

ISSUED FOR

BIDDING

S.OZTURK

S.OZTURK

M.WZOREK

J.VIAMARI

A-102

ACCESSIBILITY

IMPROVEMENTS PLAN

AS SHOWN0 4' 8' 16'

SCALE: 1/8"=1'-0"

REMOVE AND REINSTALL EXISTING

RECESSED GRILL FLOOR SYSTEM. ADJUST

HEIGHT AS NECESSARY AND PROVIDE

ADA COMPLIANT TRANSITION.

REMOVE AND DISPOSE OF

EXISTING DRINKING FOUNTAIN.

TEMPORARILY CAP AND PROTECT

EXISTING PLUMBING PIPES

ELECTRICAL CONDUITS.

LOWER FLOOR - MAIN ENTRANCE IMPROVEMENT

1/8"=1'-0"

FIRST FLOOR - DRINKING FOUNTAIN DEMOLITION

1/8"=1'-0"

FIRST FLOOR - PROPOSED DRINKING FOUNTAIN

1/8"=1'-0"

INSTALL NEW ADA COMPLIANT

BI-LEVEL DRINKING FOUNTAIN

WITH BOTTLE FILLER.

SEE SHEETS P-001 AND

E-102 FOR DETAILS.

REPAIR AND PAINT

WALL SECTION

AS NECESSARY. MATCH

EXISTING

N

N

GARDNER KEYPLAN

NO SCALE

MAIN ENTRANCE

ADA IMPROVEMENT

DRINKING FOUNTAIN

ADA IMPROVEMENT ON FIRST FLOOR

FASTEN MAT TO THE GRILLE PER

MANUFACTURER REQUIREMENTS TO

COMPLY WITH ADA STANDARDS

ACCESSIBLE BI-LEVEL DRINKING FOUNTAIN

1 1/2"=1'-0"

30" X 48" OF CLEAR FLOOR SPACE

AT LOWER DRINKING FOUNTAIN

GRILLE FLOOR SECTION DETAIL

NO SCALE

AHU-1

AHU-7

AHU-8

AHU-2

AHU-3

AHU-4

CHECKED BY:

DRAWN BY:

FILE:

APPROVED BY:

Gardner, Massachusetts

GARDNER

MIDDLE

SCHOOL ROOF

REPLACEMENT

PROJECT

City of Gardner

DATE:

PROJECT NO:

MARK DATE DESCRIPTION

A 6/20/2025 SCHEMATIC DESIGN SET

B 1/12/2026 60% DESIGN SET

C 3/9/2026 ISSUED FOR BIDDING

M1215-030-GARDNER-A-201A.dwg

04/08/2025

M1215-030

SCALE:

Pl ot te d

O n:

M ar

6, 6- 4:

pm

B y:

J Ps ze ni cz ny

La st

S av ed

3/ 4/

Ti gh e

B on d:

J:

\M \M

0) G ar dn er M id dl e S ch oo l\

D ra w in gs \A ut oC

A D

\S he et \M

-0

-G A R D

N

ER

-A -2

A .d w g

DESIGNED BY:

ISSUED FOR

BIDDING

A-201A

ALTERNATE NO.1: CEILING

REPAIR PLAN

AS SHOWN

SO

SO

MPW, ABS

0 4' 8' 16'

SCALE: 1/8"=1'-0"

N

ALTERNATE NO. 1: LOWER LEVEL PLAN

SCALE: 1/8"=1'-0"

NOTES:

1. ALL WORK SHOWN ON THIS SHEET SHALL BE

COMPLETED AS PART OF ADD ALTERNATE NO. 1.

GARDNER KEYPLAN

NO SCALE

JPV

ALTERNATE NO.1: HVAC PARTIAL LOWER LEVEL PLAN

SCALE: 1/8"=1'-0"

GARDNER KEYPLAN

NO SCALE

ALTERNATE NO.1: PARTIAL FIRST FLOOR PLAN

SCALE: 1/8"=1'-0"

REMOVE AND REINSTALL

EXISTING CEILING PANELS

AND GRIDS AS NEEDED TO

FACILITATE MECHANICAL

AND ELECTRICAL WORK

(TYP)

N

SEE ELECTRICAL PLANS FOR

LIGHTING FIXTURE SCOPE (TYP)

SEE MECHANICAL PLANS

FOR HVAC EQUIPMENT

SCOPE (TYP) REMOVE AND REINSTALL EXISTING

CEILING PANELS AND GRIDS AS

NEEDED TO FACILITATE

MECHANICAL AND ELECTRICAL

WORK (TYP)

SEE MECHANICAL PLANS

FOR HVAC EQUIPMENT

SCOPE (TYP)

REMOVE AND REINSTALL

EXISTING CEILING PANELS

AND GRIDS AS NEEDED TO

FACILITATE MECHANICAL

AND ELECTRICAL WORK

(TYP)

SEE MECHANICAL PLANS

FOR HVAC EQUIPMENT

SCOPE (TYP)

SEE ELECTRICAL PLANS FOR

LIGHTING FIXTURE SCOPE (TYP)

CUT AND REMOVE

SECTION OF EXISTING

GYPSUM BOARD CEILING

TO FACILITATE

MECHANICAL WORK (TYP)

REPAIR AND PAINT CEILING

AS NECESSARY. MATCH

EXISTING (TYP)

REMOVE AND REPLACE

DAMAGED CEILING

PANELS AND GRIDS AS

REQUIRED (TYP)

REMOVE AND REPLACE

DAMAGED CEILING

PANELS AND GRIDS (TYP)

REMOVE AND REPLACE

DAMAGED CEILING

PANELS AND GRIDS AS

REQUIRED (TYP)

REMOVE AND REPLACE

DAMAGED CEILING

PANELS AND GRIDS AS

REQUIRED (TYP)

METAL ROOFING SYSTEM (TYP)

SNOW RETENTION SYSTEM (TYP).

SEE SHEET A-513 FOR DETAILS.

DOWNSPOUT (TYP)

DORMER. SEE SHEETS A-506 AND

A-510 FOR DETAILS (TYP)

A-506

A-506

A-510

A-505

ALUMINUM DOWNSPOUT WALL BRACKETS

INSTALLED 60" O.C. FASTEN TO EXISTING

BRICK USING MASONRY SCREWS (TYP)

GUTTER SYSTEM (TYP)

SEE SHEET A-505 FOR

DETAILS.

LOUVER - 2 (L - 2). SEE H-103 FOR LOUVER SCHEDULE LOUVER - 1 (L - 1). SEE H-103 FOR

LOUVER SCHEDULE

CONNECT NEW DOWNSPOUT TO

EXISTING UNDERGROUND

DRAINAGE PIPE. CONTRACTOR

SHALL SNAKE EXISTING

DRAINAGE PIPE PRIOR TO

CONNECTING NEW DOWNSPOUT.

DOWNSPOUT SIZE TO MATCH

EXISTING. (TYP)

SPLASH PAD (TYP)

SNOW RETENTION SYSTEM (TYP).

SEE SHEET A-513 FOR DETAILS.

DOWNSPOUT (TYP)

GUTTER SYSTEM (TYP)

SEE SHEET A-505 FOR

DETAILS.

METAL ROOFING

SYSTEM (TYP)

VENT STACK. SEE SHEET

A-101 FOR DETAILS (TYP)

HVAC EQUIPMENT. SEE SHEETS

A-101 AND H-101 FOR DETAILS

(TYP)

ALUMINUM DOWNSPOUT WALL BRACKETS

INSTALLED 60" O.C. FASTEN TO EXISTING

BRICK USING MASONRY SCREWS (TYP) CONNECT NEW DOWNSPOUT TO

EXISTING UNDERGROUND

DRAINAGE PIPE. CONTRACTOR

SHALL SNAKE EXISTING

DRAINAGE PIPE PRIOR TO

CONNECTING NEW DOWNSPOUT.

DOWNSPOUT SIZE TO MATCH

EXISTING (TYP)

CHECKED BY:

DRAWN BY:

FILE:

APPROVED BY:

Gardner, Massachusetts

GARDNER

MIDDLE

SCHOOL ROOF

REPLACEMENT

PROJECT

City of Gardner

DATE:

PROJECT NO:

MARK DATE DESCRIPTION

A 6/20/2025 SCHEMATIC DESIGN SET

B 1/12/2026 60% DESIGN SET

C 3/9/2026 ISSUED FOR BIDDING

M1215-030-GARDNER - A-401.dwg

04/08/2025

M1215-030

SCALE:

Pl ot te d

O n:

M ar

6, 6- 4:

pm

B y:

J Ps ze ni cz ny

La st

S av ed

3/ 6/

Ti gh e

B on d:

J:

\M \M

0) G ar dn er M id dl e S ch oo l\

D ra w in gs \A ut oC

A D

\S he et \M

-0

-G A R D

N

ER

A

-4

.d w g

DESIGNED BY:

ISSUED FOR

BIDDING

S.OZTURK

EXTERIOR ELEVATIONS - 1

A-401 0 4' 8' 16'

SCALE: 1/8"=1'-0"

AS SHOWN

J.PSZENICZNY

M.WZOREK

J.VIAMARI

N

GARDNER MIDDLE SCHOOL KEYPLAN

NO SCALE

WEST ELEVATION - 2

1/8"=1'-0" -

2/A-401

WEST ELEVATION - 1

1/8"=1'-0" -

1/A-401

A-101

A-101

ROOF EDGE METAL FASCIA. SEE SHEET

A-502 FOR DETAILS. (TYP)

SCUPPER. SEE SHEET A-501

FOR DETAILS. (TYP)

CANOPY GUTTER

SYSTEM (TYP)

ROOF EDGE METAL FASCIA. SEE SHEET

A-502 FOR DETAILS. (TYP)

PVC CANOPY ROOFING

SYSTEM (TYP)

A-507

A-507

DOWNSPOUT (TYP)

METAL ROOFING SYSTEM (TYP)

SNOW RETENTION SYSTEM (TYP).

SEE SHEET A-513 FOR DETAILS.

DOWNSPOUT (TYP) DOWNSPOUT (TYP)

GUTTER SYSTEM (TYP). SEE SHEET

A-505 FOR DETAILS.1

A-505

A-506

A-506

A-510

A-512

A-505

CONNECT NEW

DOWNSPOUT

TO EXISTING

UNDERGROUND

DRAINAGE

PIPE (TYP)

ALUMINUM DOWNSPOUT

WALL BRACKETS

INSTALLED60" O.C.

FASTEN TO EXISTING

BRICK USING

MASONRY SCREWS (TYP)

A-507

CANOPY GUTTER

SYSTEM (TYP)

A-507

PVC CANOPY ROOFING

SYSTEM (TYP)

A-515

METAL SIDING (TYP)

CHECKED BY:

DRAWN BY:

FILE:

APPROVED BY:

Gardner, Massachusetts

GARDNER

MIDDLE

SCHOOL ROOF

REPLACEMENT

PROJECT

City of Gardner

DATE:

PROJECT NO:

MARK DATE DESCRIPTION

A 6/20/2025 SCHEMATIC DESIGN SET

B 1/12/2026 60% DESIGN SET

C 3/9/2026 ISSUED FOR BIDDING

M1215-030-GARDNER - A-401.dwg

04/08/2025

M1215-030

SCALE:

Pl ot te d

O n:

M ar

6, 6- 4:

pm

B y:

J Ps ze ni cz ny

La st

S av ed

3/ 6/

Ti gh e

B on d:

J:

\M \M

0) G ar dn er M id dl e S ch oo l\

D ra w in gs \A ut oC

A D

\S he et \M

-0

-G A R D

N

ER

A

-4

.d w g

DESIGNED BY:

ISSUED FOR

BIDDING

S.OZTURK

EXTERIOR ELEVATIONS - 2

A-402 0 4' 8' 16'

SCALE: 1/8"=1'-0"

AS SHOWN

J.PSZENICZNY

M.WZOREK

J.VIAMARI

SOUTH ELEVATION - 2

1/8"=1'-0" -

EAST ELEVATION

1/8"=1'-0" -

3 3/A-402

2/A-402

GARDNER MIDDLE SCHOOL KEYPLAN

NO SCALE

SOUTH ELEVATION - 1

3"=1'-0" -

1/A-402

N

METAL ROOFING SYSTEM (TYP) HVAC EQUIPMENT. SEE SHEETS

A-101 AND H-101 FOR DETAILS

(TYP)

DORMER. SEE SHEETS A-506 AND

A-510 FOR DETAILS (TYP)1

A-506

A-506

DOWNSPOUT (TYP)

SNOW RETENTION SYSTEM (TYP).

SEE SHEET A-513 FOR DETAILS.

CONNECT NEW DOWNSPOUT TO EXISTING

UNDERGROUND DRAINAGE PIPE. CONTRACTOR

SHALL SNAKE EXISTING DRAINAGE PIPE PRIOR

TO CONNECTING NEW DOWNSPOUT.

DOWNSPOUT SIZE TO MATCH EXISTING (TYP)

GUTTER SYSTEM (TYP)

SEE SHEET A-505 FOR

DETAILS.

ALUMINUM DOWNSPOUT WALL BRACKETS

INSTALLED 60" O.C. FASTEN TO EXISTING

BRICK USING MASONRY SCREWS (TYP)

LOUVER - 3 (L - 3). SEE H-103 FOR

LOUVER SCHEDULE

ROOF EDGE METAL FASCIA. SEE SHEET

A-502 FOR DETAILS. (TYP)

SCUPPER. SEE SHEET A-501

FOR DETAILS. (TYP)

HVAC EQUIPMENT. SEE SHEET

H-101 FOR DETAILS.

CHECKED BY:

DRAWN BY:

FILE:

APPROVED BY:

Gardner, Massachusetts

GARDNER

MIDDLE

SCHOOL ROOF

REPLACEMENT

PROJECT

City of Gardner

DATE:

PROJECT NO:

MARK DATE DESCRIPTION

A 6/20/2025 SCHEMATIC DESIGN SET

B 1/12/2026 60% DESIGN SET

C 3/9/2026 ISSUED FOR BIDDING

M1215-030-GARDNER - A-401.dwg

04/08/2025

M1215-030

SCALE:

Pl ot te d

O n:

M ar

6, 6- 4:

pm

B y:

J Ps ze ni cz ny

La st

S av ed

3/ 6/

Ti gh e

B on d:

J:

\M \M

0) G ar dn er M id dl e S ch oo l\

D ra w in gs \A ut oC

A D

\S he et \M

-0

-G A R D

N

ER

A

-4

.d w g

DESIGNED BY:

ISSUED FOR

BIDDING

S.OZTURK

EXTERIOR ELEVATIONS - 3

A-403 0 4' 8' 16'

SCALE: 1/8"=1'-0"

AS SHOWN

J.PSZENICZNY

M.WZOREK

J.VIAMARI

N

GARDNER MIDDLE SCHOOL KEYPLAN

NO SCALE

1/A-403

EAST ELEVATION

1/8"=1'-0" -

2/A-403

NORTH ELEVATION - 1

1/8"=1'-0" -

DOWNSPOUT (TYP)

SNOW RETENTION SYSTEM

(TYP). SEE SHEET

A-513 FOR DETAILS.

DOWNSPOUT (TYP)

HVAC EQUIPMENT. SEE SHEET

H-101 FOR DETAILS.

METAL ROOFING SYSTEM (TYP)

VENT STACK. SEE SHEET

A-101 FOR DETAILS (TYP) DORMER. SEE SHEETS A-506

AND A-510 FOR DETAILS (TYP)

A-506

A-506

A-510

A-505

A-505

A-505

A-512

A-512

A-512

A-514

ALUMINUM STEPPED FLASHING.

A-511

ALUMINUM DOWNSPOUT WALL BRACKETS

INSTALLED 60" O.C. FASTEN TO EXISTING

BRICK USING MASONRY SCREWS (TYP)

A-515

CONNECT NEW DOWNSPOUT TO EXISTING

UNDERGROUND DRAINAGE PIPE.

CONTRACTOR SHALL SNAKE EXISTING

DRAINAGE PIPE PRIOR TO CONNECTING

NEW DOWNSPOUT. DOWNSPOUT SIZE TO

MATCH EXISTING (TYP)

METAL

SIDING (TYP)

SNOW RETENTION SYSTEM

(TYP). SEE SHEET

A-513 FOR DETAILS.

DOWNSPOUT (TYP)

DOWNSPOUT (TYP)

HVAC EQUIPMENT. SEE SHEETS A-101

AND H-101 FOR DETAILS.

DORMER. SEE SHEETS A-506

AND A-510 FOR DETAILS (TYP)

METAL ROOFING SYSTEM (TYP)

A-505

A-506

A-506

A-510

A-512

A-512

A-505

ALUMINUM DOWNSPOUT WALL BRACKETS

INSTALLED 60" O.C. FASTEN TO EXISTING

BRICK USING MASONRY SCREWS (TYP)

CONNECT NEW DOWNSPOUT

TO EXISTING UNDERGROUND

DRAINAGE PIPE. CONTRACTOR

SHALL SNAKE EXISTING

DRAINAGE PIPE PRIOR TO

CONNECTING NEW

DOWNSPOUT. DOWNSPOUT

SIZE TO MATCH EXISTING

(TYP)

METAL SIDING (TYP)

CHECKED BY:

DRAWN BY:

FILE:

APPROVED BY:

Gardner, Massachusetts

GARDNER

MIDDLE

SCHOOL ROOF

REPLACEMENT

PROJECT

City of Gardner

DATE:

PROJECT NO:

MARK DATE DESCRIPTION

A 6/20/2025 SCHEMATIC DESIGN SET

B 1/12/2026 60% DESIGN SET

C 3/9/2026 ISSUED FOR BIDDING

M1215-030-GARDNER - A-401.dwg

04/08/2025

M1215-030

SCALE:

Pl ot te d

O n:

M ar

6, 6- 4:

pm

B y:

J Ps ze ni cz ny

La st

S av ed

3/ 6/

Ti gh e

B on d:

J:

\M \M

0) G ar dn er M id dl e S ch oo l\

D ra w in gs \A ut oC

A D

\S he et \M

-0

-G A R D

N

ER

A

-4

.d w g

DESIGNED BY:

ISSUED FOR

BIDDING

S.OZTURK

EXTERIOR ELEVATIONS - 4

A-404 0 4' 8' 16'

SCALE: 1/8"=1'-0"

AS SHOWN

J.PSZENICZNY

M.WZOREK

J.VIAMARI

NORTH ELEVATION - 2

1/8"=1'-0" -

N

GARDNER MIDDLE SCHOOL KEYPLAN

NO SCALE

SOUTH ELEVATION - 3

1/8"=1'-0" -

1/A-404 2/A-404

A-101

REMOVE AND DISPOSE OF EXISTING

ROOFING SYSTEM INCLUDING MEMBRANE,

FIBERBOARD, INSULATION, FASTENERS, ICE AND

WATER SHIELD, AND VAPOR BARRIER

EXISTING METAL FLASHING TO REMAIN. PULL

BACK FLASHING TO FACILITATE DEMOLITION.

COVER BOARD

EPDM ROOFING MEMBRANE

TAPERED RIGID INSULATION

SPLICE WITH EPDM SEAM TAPE (TYP)

RESTORE EXISTING METAL FLASHING TO ORIGINAL

POSITION AFTER INSTALLATION OF EPDM FLASHING

AND TERMINATION BAR.

STAINLESS-STEEL TERMINATION BAR AND SEALANT

FASTENED WITH APPROPRIATE FASTENERS 12" O.C.

EPDM FLASHING TO RUN UP

UNDERNEATH THE METAL FLASHING

RIGID INSULATION

AIR/VAPOR BARRIER

SUBSTRATE BOARD

BOND BREAKER TAPE AND

SEALANT

CONFIRM CONDITION OF STONE JOINT SEALANTS. APPLY

NEW SEALANT TO REPAIR DAMAGED SEALANTS AS NEEDED.

CONTINUOUS BEAD OF LAP SEALANT (TYP)

2" M

IN

COVER BOARD

EPDM ROOFING MEMBRANE

TAPERED RIGID

INSULATION

RIGID INSULATION

AIR/VAPOR BARRIER

SUBSTRATE BOARD

EPDM FLASHING

PRESERVATIVE-TREATED WOOD BLOCKING

AS REQUIRED (TYP)

SET ALUMINUM SCUPPER IN

SEALANT. SEE SHEET A-518 FOR

ADDITIONAL DETAILS.

METAL FASCIA

SCUPPER COUNTER-FLASHING

RE-INSTALL EXISTING STONE COPING AFTER SCUPPER

COUNTER-FLASHING INSTALLATION CONFIRM CONDITION OF

STONE JOINT SEALANTS. APPLY NEW SEALANT TO REPAIR

DAMAGED SEALANTS AS NEEDED.

CONTINUOUS BEAD OF LAP SEALANT

SPLICE WITH EPDM SEAM TAPE (TYP)

RESTORE EXISTING METAL FLASHING TO ORIGINAL POSITION

AFTER INSTALLATION OF EPDM FLASHING AND TERMINATION BAR.

PRESERVATIVE-TREATED WOOD

BLOCKING AS REQUIRED (TYP)

CONTINUOUS ALUMINUM

CLEAT (TYP)

BACKER ROD AND SEALANT

EXTEND SCUPPER 4"

FROM ROOF EDGE (TYP)

REMOVE AND DISPOSE OF EXISTING

ROOFING SYSTEM INCLUDING MEMBRANE,

FIBERBOARD, INSULATION, BLOCKING,

FASTENERS AND ICE AND WATER SHIELD

EXISTING COUNTER FLASHING TO REMAIN

CUT, REMOVE, AND

DISPOSE SECTION OF

EXISTING CMU BLOCK

OVER EXISTING SCUPPER.

REMOVE AND DISPOSE

EXISTING L.C.C SCUPPER

LINER AND LEADER BOX

REMOVE AND DISPOSE

EXISTING METAL FASCIA

CUT AND REMOVE SECTION OF STONE COPING

ABOVE THE EXISTING SCUPPER. EXTEND

REMOVAL OF STONE COPING TO NEAREST JOINT.

REMOVE AND DISPOSE OF EXISTING PLYWOOD

CHECKED BY:

DRAWN BY:

FILE:

APPROVED BY:

Gardner, Massachusetts

GARDNER

MIDDLE

SCHOOL ROOF

REPLACEMENT

PROJECT

City of Gardner

DATE:

PROJECT NO:

MARK DATE DESCRIPTION

A 6/20/2025 SCHEMATIC DESIGN SET

B 1/12/2026 60% DESIGN SET

C 3/9/2026 ISSUED FOR BIDDING

M1215-030-GARDNER - A-501.dwg

04/08/2025

M1215-030

SCALE:

Pl ot te d

O n:

M ar

6, 6- 3:

pm

B y:

J Ps ze ni cz ny

La st

S av ed

3/ 6/

Ti gh e

B on d:

J:

\M \M

0) G ar dn er M id dl e S ch oo l\

D ra w in gs \A ut oC

A D

\S he et \M

-0

-G A R D

N

ER

A

-5

.d w g

DESIGNED BY:

ISSUED FOR

BIDDING

S.OZTURK

ROOF DETAILS - 1

A-501 0 3" 6" 9"

SCALE: 3"=1'-0"

AS SHOWN

S.OZTURK

M.WZOREK

J.VIAMARI

TYPICAL STONE WALL PARAPET EDGE DETAIL

3"=1'-0" -

EXISTING

PROPOSED

EXISTING

PROPOSED

TYPICAL SCUPPER DETAIL

3"=1'-0" -

NOTES:

1. SEE SHEET A-518 FOR ADDITIONAL OVERFLOW SCUPPER INSTALLATION DETAILS

RIGID INSULATION

COVER BOARD

EPDM ROOFING MEMBRANE

TAPERED RIGID INSULATION

SUBSTRATE BOARD

TAPERED EDGE STRIPS TO MAINTAIN

CONSISTENT BLOCKING HEIGHT

ROOF EDGE METAL

FASCIA AND SECUREMENT -

CONTINUOUS EXTRUDED

ALUMINUM CLEAT

WITH SNAP-ON

ALUMINUM COVER

CONTINUOUS ALUMINUM HOOK

STRIP WITH STAINLESS

FASTENERS AT 12" MAX. OC

PRESERVATIVE-TREATED WOOD

BLOCKING AS NEEDED (TYP)

AIR/VAPOR BARRIER

WATER CUT OFF MASTIC (TYP)

STAINLESS FASTENERS

12" MAX O.C.

ALUMINUM FASCIA WITH

CONTINUOUS CLEAT

GASKETED STAINLESS STEEL

FASTENERS (TYP)

REMOVE AND DISPOSE OF EXISTING

ROOFING SYSTEM INCLUDING MEMBRANE,

FIBERBOARD, INSULATION, BLOCKING,

FASTENERS AND VAPOR BARRIER

REMOVE AND

DISPOSE EXISTING

FLASHING

REMOVE AND DISPOSE OF EXISTING

ROOFING SYSTEM INCLUDING MEMBRANE,

FIBERBOARD, INSULATION, AND

VAPOR BARRIER

CUT OFF AND DISPOSE OF EXISTING

THROUGH WALL FLASHING

REMOVE AND DISPOSE OF EXISTING BRICK FOR

NEW THROUGH-WALL FLASHING AS NECESSARY.

COORDINATE WITH NEW INSULATION HEIGHT.

RIGID INSULATION

COVERBOARD

EPDM ROOFING MEMBRANE

TAPERED RIGID INSULATION

SPLICE WITH EPDM SEAM TAPE (TYP)

STAINLESS-STEEL TERMINATION BAR AND SEALANT

FASTENED WITH APPROPRIATE FASTENERS 12" O.C.

STAINLESS 2-PIECE

COUNTER FLASHING WITH CANT

WEEPS 24" O.C.

SET NEW STAINLESS STEEL THROUGH

WALL FLASHING 3" INTO EXISTING JOINT.

PROVIDE WEDGE W/ SEALANT.

BRICK MASONRY

(MATCH EXISTING)

MIN. 5/8" PRESERVATIVE TREATED

PLYWOOD WITH CHAMFERED TOP EDGE

SUBSTRATE BOARD

AIR/VAPOR BARRIER

M

IN

STAINLESS FASTENERS 12" O.C.

STAINLESS STEEL CLEAT (TYP)

STAINLESS FASTENERS 12" O.C.

CONTINUOUS BEAD OF LAP SEALANT

STAINLESS COUNTER FLASHING RECEIVER

TERMINATE EPDM FLASHING BENEATH RECEIVER

CHECKED BY:

DRAWN BY:

FILE:

APPROVED BY:

Gardner, Massachusetts

GARDNER

MIDDLE

SCHOOL ROOF

REPLACEMENT

PROJECT

City of Gardner

DATE:

PROJECT NO:

MARK DATE DESCRIPTION

A 6/20/2025 SCHEMATIC DESIGN SET

B 1/12/2026 60% DESIGN SET

C 3/9/2026 ISSUED FOR BIDDING

M1215-030-GARDNER - A-501.dwg

04/08/2025

M1215-030

SCALE:

Pl ot te d

O n:

M ar

6, 6- 4:

pm

B y:

J Ps ze ni cz ny

La st

S av ed

3/ 6/

Ti gh e

B on d:

J:

\M \M

0) G ar dn er M id dl e S ch oo l\

D ra w in gs \A ut oC

A D

\S he et \M

-0

-G A R D

N

ER

A

-5

.d w g

DESIGNED BY:

ISSUED FOR

BIDDING

ROOF DETAILS - 2

A-502 0 3" 6" 9"

SCALE: 3"=1'-0"

AS SHOWN

S.OZTURK

M.WZOREK

J.VIAMARI

TYPICAL EPDM ROOF EDGE DETAIL

3"=1'-0" -

EXISTING

PROPOSED

TYPICAL EPDM ROOF BASE TIE-IN

3"=1'-0" -

EXISTING

PROPOSED

S.OZTURK

RIGID INSULATION

COVER BOARD

EPDM ROOFING MEMBRANE

TAPERED RIGID INSULATION

SUBSTRATE BOARD

TAPERED EDGE STRIPS TO MAINTAIN

CONSISTENT BLOCKING HEIGHT

CONTINUOUS ALUMINUM HOOK

STRIP WITH STAINLESS

FASTENERS AT 12" MAX. OC

PRESERVATIVE-TREATED WOOD

BLOCKING AS NEEDED (TYP)

AIR/VAPOR BARRIER

WATER CUT OFF MASTIC (TYP)

STAINLESS FASTENERS 12" O.C.

ROOF EDGE FASCIA

METAL AND

SECUREMENT -

CONTINUOUS

EXTRUDED ALUMINUM

CLEAT WITH SNAP-ON

ALUMINUM COVER

ALUMINUM FASCIA WITH

CONTINUOUS CLEAT

GASKETED STAINLESS STEEL

FASTENERS (TYP)

REMOVE AND DISPOSE OF EXISTING

ROOFING SYSTEM INCLUDING MEMBRANE,

FIBERBOARD, INSULATION, BLOCKING,

FASTENERS AND VAPOR BARRIER

REMOVE AND

DISPOSE EXISTING

FLASHING

REMOVE AND DISPOSE OF EXISTING

ROOFING SYSTEM INCLUDING MEMBRANE,

FIBERBOARD, INSULATION, BLOCKING AND

VAPOR BARRIER

REMOVE AND DISPOSE OF EXISTING

PARAPET CAP, BLOCKING AND METAL FASCIA

CONTINUOUS ALUMINUM HOOK WITH STAINLESS FASTENERS 12" O.C. (TYP)

EPDM MEMBRANE FLASHING

PRESERVATIVE-TREATED WOOD BLOCKING

AS REQUIRED (TYP)

PREFINISHED ALUMINUM COPING

COVER BOARD

EPDM ROOFING MEMBRANE

TAPERED RIGID INSULATION

PRESERVATIVE-TREATED WOOD BLOCKING

AS REQUIRED (TYP)

RIGID INSULATION

AIR/VAPOR BARRIER

SUBSTRATE BOARD

12"

1/4"

CONTINUOUS BEAD OF LAP SEALANT

SPLICE WITH EPDM SEAM TAPE (TYP)

PROVIDE SELF-ADHERED

AIR/VAPOR BARRIER

TRANSITION OVER

EXISTING AIR/VAPOR

BARRIER

CHECKED BY:

DRAWN BY:

FILE:

APPROVED BY:

Gardner, Massachusetts

GARDNER

MIDDLE

SCHOOL ROOF

REPLACEMENT

PROJECT

City of Gardner

DATE:

PROJECT NO:

MARK DATE DESCRIPTION

A 6/20/2025 SCHEMATIC DESIGN SET

B 1/12/2026 60% DESIGN SET

C 3/9/2026 ISSUED FOR BIDDING

M1215-030-GARDNER - A-501.dwg

04/08/2025

M1215-030

SCALE:

Pl ot te d

O n:

M ar

6, 6- 3:

pm

B y:

J Ps ze ni cz ny

La st

S av ed

3/ 6/

Ti gh e

B on d:

J:

\M \M

0) G ar dn er M id dl e S ch oo l\

D ra w in gs \A ut oC

A D

\S he et \M

-0

-G A R D

N

ER

A

-5

.d w g

DESIGNED BY:

ISSUED FOR

BIDDING

ROOF DETAILS - 3

A-503 0 3" 6" 9"

SCALE: 3"=1'-0"

AS SHOWN

S.OZTURK

M.WZOREK

J.VIAMARI

TYPICAL EPDM ROOF EDGE DETAIL - 2

3"=1'-0" -

EXISTING

PROPOSED

TYPICAL PARAPET DETAIL AT CURTAIN WALL

3"=1'-0" -

EXISTING

SPLICE WITH EPDM SEAM TAPE (TYP)

INTEGRAL VAPOR BARRIER

INSULATION SUPPORT

FIBERGLASS BATT INSULATION

IN POLY SLEEVE

TAPERED RIGID

INSULATION (TYP)

COVER BOARD (TYP)

AIR/VAPOR BARRIER (TYP)

RIGID INSULATION (TYP)

SUBSTRATE BOARD (TYP)

EPDM ROOFING

MEMBRANE (TYP)

FOAM ROD DIA. 1.5 TIMES LARGER THAN MAXIMUM GAP

REINFORCED TERMINATION STRIP (TYP)

PRESERVATIVE-TREATED WOOD BLOCKING

AS REQUIRED (TYP)

RUN AIR/VAPOR BARRIER UP

TO TOP OF BLOCKING

RIGID INSULATION

SUBSTRATE BOARD

AIR/VAPOR BARRIER

CANT STRIP (TYP)

SPLICE WITH EPDM SEAM TAPE (TYP)

REMOVE AND DISPOSE OF EXISTING

ROOFING SYSTEM INCLUDING MEMBRANE,

FIBERBOARD, INSULATION, AND

VAPOR BARRIER

REMOVE AND DISPOSE OF EXISTING

FOAM EXPANSION TUBE AND COMPRESSIBLE

INSULATION

REMOVE AND DISPOSE OF EXISTING

ROOFING SYSTEM INCLUDING MEMBRANE,

FIBERBOARD, INSULATION, BLOCKING,

FASTENERS AND VAPOR BARRIER

REMOVE AND DISPOSE OF EXISTING

EXPANSION TUBE AND

COMPRESSIBLE INSULATION

EXISTING THROUGH-WALL FLASHING

TO REMAIN

RIGID INSULATION

COVERBOARD

EPDM ROOFING MEMBRANE

TAPERED RIGID

INSULATION

MIN. 5/8" PRESERVATIVE TREATED

PLYWOOD WITH CHAMFERED TOP EDGE

SUBSTRATE BOARD

AIR/VAPOR BARRIER

M

IN

FOAM ROD DIA. 1.5 TIMES LARGER THAN MAXIMUM GAP

INTEGRAL VAPOR

BARRIER INSULATION

SUPPORT

FIBERGLASS BATT

INSULATION IN

POLY SLEEVE

REINFORCED TERMINATION STRIP (TYP)

PRESERVATIVE-TREATED WOOD BLOCKING

AS REQUIRED (TYP)

EXISTING THROUGH-WALL FLASHING

STAINLESS-STEEL TERMINATION

BAR AND SEALANT FASTENED WITH

APPROPRIATE FASTENERS 12" O.C.

EPDM FLASHING TO RUN UP UNDERNEATH

THE THROUGH-WALL FLASHING

SPLICE WITH EPDM SEAM TAPE (TYP)

CONTINUOUS BEAD OF LAP SEALANT

CHECKED BY:

DRAWN BY:

FILE:

APPROVED BY:

Gardner, Massachusetts

GARDNER

MIDDLE

SCHOOL ROOF

REPLACEMENT

PROJECT

City of Gardner

DATE:

PROJECT NO:

MARK DATE DESCRIPTION

A 6/20/2025 SCHEMATIC DESIGN SET

B 1/12/2026 60% DESIGN SET

C 3/9/2026 ISSUED FOR BIDDING

M1215-030-GARDNER - A-501.dwg

04/08/2025

M1215-030

SCALE:

Pl ot te d

O n:

M ar

6, 6- 3:

pm

B y:

J Ps ze ni cz ny

La st

S av ed

3/ 6/

Ti gh e

B on d:

J:

\M \M

0) G ar dn er M id dl e S ch oo l\

D ra w in gs \A ut oC

A D

\S he et \M

-0

-G A R D

N

ER

A

-5

.d w g

DESIGNED BY:

ISSUED FOR

BIDDING

ROOF DETAILS - 4

A-504 0 3" 6" 9"

SCALE: 3"=1'-0"

AS SHOWN

S.OZTURK

M.WZOREK

J.VIAMARI

TYPICAL EXPANSION JOINT

3"=1'-0" -

EXISTING

PROPOSED

TYPICAL PARAPET DETAIL AT CURTAIN WALL

3"=1'-0" -

EXISTING

PREFINISHED

ALUMINUM

GUTTER

MIN. DIMENSIONS:

5" W x 8" H

PREFINISHED

ALUMINUM

DOWNSPOUT/LEADER

IN SAME LOCATION

AS EXISTING

GUTTER STRAP

HEAT-RESISTANT UNDERLAYMENT (TYP)

UNDERLAYMENT TO EXTEND

DOWN THE FACE OF THE

BLOCKING

6" RIGID INSULATION (TYP)

METAL ROOF PANEL

RETAINER CLIP SET IN

BUTYL SEALANT AND

SECURED WITH FASTENERS

PREFINISHED ALUMINUM

FLASHING

PRESERVATIVE-TREATED

WOOD BLOCKING AS

REQUIRED (TYP)

METAL DECK (TYP)

SUBSTRATE BOARD (TYP)

AIR/VAPOR BARRIER (TYP)

COVERBOARD (TYP)

GUTTER SUPPORT

BRACKET

BOND BREAKER TAPE AND

SEALANT

EXTEND SECOND LAYER OF UNDERLAYMENT A MINIMUM

OF 2' BEYOND EXTERIOR BUILDING WALL

REMOVE AND DISPOSE OF EXISTING METAL ROOFING SYSTEM

INCLUDING PANELS, FIBERBOARD, INSULATION, BLOCKING AND

ICE AND WATER SHIELD

REMOVE AND DISPOSE OF

EXISTING GUTTERS AND

DOWNSPOUTS

REMOVE AND DISPOSE OF EXISTING

METAL ROOFING SYSTEM INCLUDING

PANELS, FIBERBOARD, INSULATION,

BLOCKING AND ICE AND WATER

SHIELD

REMOVE AND

DISPOSE OF EXISTING

METAL FASCIA

ROOF EDGE METAL FLASHING

CONTINUOUS ALUMINUM HOOK

STRIP WITH STAINLESS

FASTENERS AT 12" MAX. OC

RUN UNDERLAYMENT DOWN

THE FACE OF THE BLOCKING

PRESERVATIVE-TREATED

WOOD BLOCKING AS

REQUIRED (TYP)

FIELD FORM PANEL LEG TO

I.D. OF "J" CLOSURE

J-CHANNEL WITH TURNDOWN

METAL ROOF PANEL (TYP)

HEAT-RESISTANT UNDERLAYMENT (TYP)

6" RIGID INSULATION (TYP)

AIR/VAPOR BARRIER (TYP)

SUBSTRATE BOARD (TYP)

SUPPORT PLATE

COVERBOARD (TYP)

CLIP FASTENERS TO

PENETRATE TOP FLUTE OF

METAL DECK SUBSTRATE

5/8" MIN THREAD LENGTH

FASCIA TO SOFFIT FLASHING

BUTYL SEALANT TAPE

CHECKED BY:

DRAWN BY:

FILE:

APPROVED BY:

Gardner, Massachusetts

GARDNER

MIDDLE

SCHOOL ROOF

REPLACEMENT

PROJECT

City of Gardner

DATE:

PROJECT NO:

MARK DATE DESCRIPTION

A 6/20/2025 SCHEMATIC DESIGN SET

B 1/12/2026 60% DESIGN SET

C 3/9/2026 ISSUED FOR BIDDING

M1215-030-GARDNER - A-501.dwg

04/08/2025

M1215-030

SCALE:

Pl ot te d

O n:

M ar

6, 6- 3:

pm

B y:

J Ps ze ni cz ny

La st

S av ed

3/ 6/

Ti gh e

B on d:

J:

\M \M

0) G ar dn er M id dl e S ch oo l\

D ra w in gs \A ut oC

A D

\S he et \M

-0

-G A R D

N

ER

A

-5

.d w g

DESIGNED BY:

ISSUED FOR

BIDDING

ROOF DETAILS - 5

A-505 0 3" 6" 9"

SCALE: 3"=1'-0"

AS SHOWN

S.OZTURK

M.WZOREK

J.VIAMARI

TYPICAL METAL EDGE DETAIL - 1

3"=1'-0" -

EXISTING

PROPOSED

TYPICAL METAL EDGE DETAIL - 2

3"=1'-0" -

EXISTING

ROOF EDGE METAL FASCIA

CONTINUOUS ALUMINUM CLEAT

WITH STAINLESS FASTENERS

AT 12" MAX. OC

UNDERLAYMENT TO EXTEND

DOWN THE FACE OF THE

BLOCKING

RETAINER CLIP SET IN

BUTYL SEALANT AND

SECURED WITH FASTENERS

PRESERVATIVE-TREATED

WOOD BLOCKING AS

REQUIRED (TYP)

PRESERVATIVE-TREATED

PLYWOOD (TYP)

FLAT SEAM METAL TRIM

METAL CLEAT

LOUVER

HEAT-RESISTANT HEAT-RESISTANT UNDERLAYMENT (TYP)

RIGID INSULATION

METAL ROOF PANEL

SUBSTRATE BOARD (TYP)

AIR/VAPOR BARRIER (TYP)

COVERBOARD (TYP)

12"

1"

BUTYL SEALANT TAPE

REMOVE AND DISPOSE OF EXISTING

METAL ROOFING SYSTEM INCLUDING

PANELS, FIBERBOARD, INSULATION,

BLOCKING AND ICE AND WATER

SHIELD

REMOVE AND DISPOSE OF EXISTING

LOUVERS AND VENTS

REMOVE AND DISPOSE OF EXISTING

METAL FASCIA

REMOVE AND DISPOSE OF EXISTING

PLYWOOD AND METAL TRIM

REMOVE AND DISPOSE OF EXISTING

METAL ROOFING SYSTEM INCLUDING PANELS,

FIBERBOARD, INSULATION, BLOCKING AND

ICE AND WATER SHIELD

REMOVE AND DISPOSE OF EXISTING

LOUVERS AND VENTS

LOUVER

FLASHING WITH "Z" CLOSURE

HEAT-RESISTANT

UNDERLAYMENT (TYP)

RIGID INSULATION

METAL ROOF PANEL

COVERBOARD (TYP)

PRESERVATIVE-TREATED

WOOD BLOCKING AS

REQUIRED (TYP)

UNDERLAYMENT FLASHING STRIP TO

EXTEND 4" UP THE SIDE AND

OVERLAP PANEL AND "Z" CLOSURE

AIR/VAPOR BARRIER (TYP)

SUBSTRATE BOARD (TYP)

BOND BREAKER TAPE AND

SEALANT

END DAM

CHECKED BY:

DRAWN BY:

FILE:

APPROVED BY:

Gardner, Massachusetts

GARDNER

MIDDLE

SCHOOL ROOF

REPLACEMENT

PROJECT

City of Gardner

DATE:

PROJECT NO:

MARK DATE DESCRIPTION

A 6/20/2025 SCHEMATIC DESIGN SET

B 1/12/2026 60% DESIGN SET

C 3/9/2026 ISSUED FOR BIDDING

M1215-030-GARDNER - A-501.dwg

04/08/2025

M1215-030

SCALE:

Pl ot te d

O n:

M ar

6, 6- 3:

pm

B y:

J Ps ze ni cz ny

La st

S av ed

3/ 6/

Ti gh e

B on d:

J:

\M \M

0) G ar dn er M id dl e S ch oo l\

D ra w in gs \A ut oC

A D

\S he et \M

-0

-G A R D

N

ER

A

-5

.d w g

DESIGNED BY:

ISSUED FOR

BIDDING

ROOF DETAILS - 6

A-506 0 3" 6" 9"

SCALE: 3"=1'-0"

AS SHOWN

S.OZTURK

M.WZOREK

J.VIAMARI

TYPICAL DORMER EDGE DETAIL

3"=1'-0" -

EXISTING

PROPOSED

TYPICAL DORMER BASE TIE-IN DETAIL

3"=1'-0" -

EXISTING

PRESERVATIVE-TREATED WOOD BLOCKING AS REQUIRED (TYP)

RUN AIR/VAPOR BARRIER UP TO TOP OF BLOCKING (TYP)

COVERBOARD

PVC ROOFING MEMBRANE

SUBSTRATE

BOARD

AIR/VAPOR

BARRIER

3" RIGID

INSULATION

METAL CLEAT

HOOK STRIP (TYP)

PVC FLASHING STRIP (TYP)

HOT-AIR WELDED SEAM (TYP)

PVC-CLADDED METAL

FASCIA COVER (TYP)

STAINLESS-STEEL

GROMMETED

FASTENERS. 12" O.C.

1-1/4" HOT DIPPED STAINLESS ROOF NAILS AT 4" O.C.

MAX STAGGERED 1/2" MIN. 1.5" FROM EDGE OF ROOF

REMOVE AND DISPOSE OF EXISTING

ROOFING SYSTEM INCLUDING MEMBRANE,

FIBERBOARD, INSULATION, BLOCKING,

FASTENERS AND VAPOR BARRIER

REMOVE AND

DISPOSE OF

EXISTING METAL

FLASHING

REMOVE AND DISPOSE OF

EXISTING METAL…