G - Drawings- Elmendorf Solicitation Issue - All Bound.pdf
PDF 20 MB Posted
- Attached to
- JBER Elmendorf, Alaska- Burger King Image Update
- Solicitation number
- GNFR-FC-ELM-24-20267
- Issued by
-
Department of Defense
About this file
This document outlines a federal contract solicitation for renovations to a Burger King located on Joint Base Elmendorf-Richardson in Alaska. The solicitation seeks to renovate 3,668 square feet of the existing Burger King, including modifying interior and exterior materials, demolishing an atrium and converting it to exterior space, replacing interior decor, seating and finishes in customer areas, replacing drive-thru signage, and modifying mechanical, electrical and plumbing distribution. The roof and parapet will also be repaired. Work will take place in an active, operating facility and will be phased. The Department of Defense Exchange will award the contract based on best value, and may award to a single contractor for both this project and a paired project at lowest combined price. The start date may occur after completion of the paired project if required. Interested contractors must refer to the provided link to participate and acknowledge any amendments when submitting a proposal.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Overall Scope of Work for this renovation A. Scope of Improvements for the SITE include:
1. NOTE: The existing Menu boards appear to be recent Digital menu boards.
2. New Garden Grill Height Sensor Bar and Canopy to replace the existing items.
3. New directional signage on existing foundations, poles, and wiring.
4. Repair and refinish dumpster enclosure doors.
5. REPAIR DAMAGED AREAS AND Seal and restripe parking lot.
6. New landscape where green house is removed.
7. All signage to be supplied and installed by GC
B. Scope of Improvements for the EXTERIOR include:
1. Reconfiguration of the entry and drive through window walls to new Burger King Design Standards.
2. New entry vestibule tower.
3. Installation of new Burger King Design Standard finishes.
4. Replacement of existing exterior lighting with LED lighting.
5. Replace existing building signage to match Burger
King Design Standards.
6. Repair of red LED lighting band if required.
7. Removal of green house and mansard roofs.
Replace with current BK standard parapets.
8. Install new metal canopies.
9. New aluminum windows and storefront doors.
C. Scope of Improvements for the DINING AREA, and
CORRIDORS include:
1. Upgrade of existing finishes to new Burger King
Standard.
2. New ceiling tiles and grid, new paint, new wainscot panel, etc. as specified on SCI drawings.
3. Upgrade of existing seating and fixtures to new
Burger King Standard – refer to sci standards for specifications and locations.
4. Upgrade of existing floor tile to new Burger King Standard.
5. Install new Ceiling treatment refer to SCI drawings.- Trellis and associated lighting -Bid Option 2
6. Relaminate interior front of house doors.
7. Air handler work as noted by MEP.
8. New baseboard heaters as noted by MEP.
9. Outlets required at dining room for customer devices
10. Wiring for future ordering kiosks above order line ceiling.
11. Interior graphics by SCI.
12. Remove and replace drywall in drink station area with green board.
13. Existing light fixtures to remain Unless noted otherwise. Lighting in conflict with the installation of the new Pergola is to be removed to allow the installation of the Pergola and pendant lighting as Base Bid
11. Drink Station ceiling and lighting to remain.
12. New lighting in Serving Area (in front of the menu board bulkhead and behind the front counter/POS stations.
D. Scope of Improvements for the SERVING AREA and SUPPORT AREA include:
1. Upgrade of serving counter to New Burger King Standard-coordinate with SCI.
2. Replacement of select Equipment as noted.
3. 25% replacement of tile and grout in back of house as needed.
BID OPTIONS
1. Dining room
1. Ceiling treatment - Trellis with associated lighting.
2. UPGRADE OF EXISTING LIGHTING PER
ELECTICAL DRAWINGS AND SEATING
CONCEPTS.
3. New LED lighting above the Drink Station area.
2. Restrooms
1. Upgrade of existing finishes to new Burger King Standards.
2. Upgrade of existing lighting to LED fixtures.
3. Upgrade of existing floor tile to new Burger King
Standard.
4. Upgrade of existing restroom fixtures and accessories.
5. Relaminate toilet room doors and replace hardware
6. New HVAC work per the Mechanical Drawings.
7. Replace all toilet Fixtures with new, matching fixtures and fittings.
8. Replace existing toilet accessories with new accessories per drawings.
3. Kitchen and Back of House (BOH)
1. Replace existing ceiling tiles and grid - Refer to SCI drawings.
2. Replace existing light fixtures with new LED fixtures.
NAME MATTHEW CADWALLADER
ADDRESS 3911 S. WALTON WALKER BLVD.,
DALLAS, TEXAS 75236-1598
PHONE (214) 312-2389
FAX -
eMAIL cadwalladerMJ@aafes.com
NAME QUORUM ARCHITECTS, INC.
ADDRESS 825 W. VICKERY BLVD., SUITE 100
FORT WORTH, TX 76104
CONTACT DAVID DUMAN, AIA
PHONE (817) 546-6318
FAX (817) 738-9524
NAME DC4 MECHANICAL
ADDRESS 1827 HILL RIDGE DR.
FLOWER MOUND, TX 75028
CONTACT COURTNEY WUISTINGER
PHONE (214) 934-4191
eMAIL courtney@dc4mechanical.com
PROJECT
LOCATION
PROJECT
LOCATION
A. The general building code used for design of this project is the IBC (International Building Code) 2021. This code governs architecture, structure, mechanical, plumbing, civil, electrical and accessibility. This code should be used in conjunction with the following codes and standards:
1. 2021 IEBC (International Existing Building Code)
2. UFC 1-200-01
3. 2021 International Fire Code
4. DoD UFC (Unified Services Criteria) as it applies to Exchange projects, including Force Protection issues.
5. NFPA 70 – 2023 for design of electrical systems and support
6. 2021 IMC (International Mechanical Code)
7. 2021 IPC (International Plumbing Code) for design of plumbing s ystems and support
8. UFC 3-430-05 and NFPA 54 – 2021 for design of natural gas utility lines
9. ADAAG (Americans with Disabilities Act Accessibility Guidelines) for the implementation of design elements for the promotion of accessibility in the use of the project
10. Comply with all applicable Federal, State and local laws and regulations providing for environmental protection and pollution control.
NAME LALONDE ENGINEERING, INC.
ADDRESS 6617 RED BUD ROAD
FORT WORTH, TX 76135
CONTACT PHILIPPE LALONDE
PHONE (8170 307-8266
eMAIL plalonde@lalonde-eng.com
STRUCTURAL
S101 GENERAL NOTES 01/05/24
S201 ROOF FRAMING PLAN 01/05/24
S301 FRAMING SECTIONS 01/05/24
S302 FRAMING SECTIONS 01/05/24
S303 FRAMING SECTIONS 01/05/24
MECHANICAL
M1.01 FLOOR PLAN - MECHANICAL 01/05/24
M1.02 FLOOR PLAN - MECHANICAL PIPING 01/05/24
M2.01 MECHANICAL SCHDEULES & DETAILS 01/05/24
MD1.01 FLOOR PLAN - MECHANICAL DEMOLITION 01/05/24
MD1.02 FLOOR PLAN - PLUMBING DEMO 01/05/24
ELECTRICAL
E1.01 FLOOOR PLAN - LIGHTING 01/05/24
E2.01 FLOOR PLAN - POWER 01/05/24
E3.01 ELECTRICAL SCHEDULE & DETAILS 01/05/24
ED1.01 FLOOR PLAN - ELECTRICAL 01/05/24
SE.01 SITE PLAN - ELECTRICAL 01/05/24
PLUMBING
FS1.01 FLOOR PLAN - FIRE SPRINKLER 01/05/24
P1.01 FLOOR PLAN - PLUMBING 01/05/24
P2.01 PLUMBING SCHEDULES & DETAILS 01/05/24
PD1.01 FLOOR PLAN - PLUMBING DEMO 01/05/24
GENERAL NOTES PROJECT TEAM INDEX TO DRAWINGS
AAFES PROJECT MANAGER
VICINITY MAP
ARCHITECT
MEP ENGINEER
SITE LOCATION NO SCALE
SCOPE OF WORK
IMAGE UPGRADE:
EXCHANGE PROJECT MANAGER:
EXCHANGE CONTRACTING OFFICER:
QUORUM ARCHITECTS:
APPLICABLE CODES
GENERAL CONTRACTOR:
STRUCTURAL ENGINEER
SITE LOCATION
SITE LOCATION NO SCALE
ELMENDORF AFB, AK
ARMY & AIR FORCE
EXCHANGE SERVICE
ELMENDORF AFB, AK
BURGER KING
ELMENDORF AFB, AK
1. GENERAL CONTRACTOR SHALL FIELD SURVEY THE LOCATION AND VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS PRIOR TO CONSTRUCTION. ANY DISCREPANCIES SHALL BE REPORTED TO THE AAFES AND ARCHITECT. ALL PROSPECTIVE GENERAL CONTRACTORS HAVE THE OPPORTUNITY TO SCHEDUE A SITE VISIT PRIOR TO BIDDING. CONTACT THE CONTRACTING OFFICER AND AAFES PROJECT MANAGER TO SCHEDULE DATE AND TIME OF SITE VISIT.
2. GENERAL CONTRACTOR SHALL COMPLETE ALL WORK AS INDICATED ON THESE PLANS, UNLESS OTHERWISE NOTED. CONTACT THE POST DPW TO OBTAIN ALL
AVAILABLE AS-BUILT DRAWINGS
3. GENERAL CONTRACTOR SHALL OBTAIN PERMITS, APPROVALS, INSPECTIONS, CERTIFICATE FOR COMPLIANCE AND CERTIFICATE OF OCCUPANCY AS REQUIRED, UNLESS OTHERWISE NOTED. SEE NOTE 18.
4. GENERAL CONTRACTOR SHALL CHECK IN WITH AND COORDINATE ALL WORK WITH THE POST DPW'S PROJECT MANAGER AND POST ENVIRONMENTAL.
5. GENERAL CONTRACTOR SHALL PROVIDE TEMPORARY CONSTRUCTION BARRICADES AND TEMPORARY POWER, LIGHT AND TELEPHONE IN ACCORDANCE WITH ALL REQUIREMENTS OF BASE / POST. GENERAL CONTRACTOR SHALL REMOVE ALL OF THESE ITEMS AT THE COMPLETION OF WORK. CONTRACTOR SHALL PROVIDE A TEMPORARY CONSTRUCTION FENCE AROUND ENTIRE PROJECT SITE. GENERAL CONTRACTOR SHALL HAVE ENTIRE PROJECT SITE CLEANED UPON COMPLETION OF WORK BY A PROFESSIONAL CLEANING SERVICE. CONTRACTORSHALL CLEAN AND SECURE ENTIRE PROJECT SITE DAILY BASIS.
6. GENERAL CONTRACTOR SHALL MAINTAIN ON SITE AT ALL TIMES, ALL APPROVED & AS-BUILT DRAWINGS INCLUDING REVISIONS AND ADDENDA.
7. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY & OSHA PRECAUTIONS AND BASE SAFETY REQUIREMENTS DURING CONSTRUCTION.
8. GENERAL CONTRACTOR SHALL COMPLETE ALL WORK IN A NEAT AND PROFESSIONAL MANNER.
9. GENERAL CONTRACTOR SHALL PROVIDE A ONE (1) YEAR WARRANTY ON ALL WORK AND MATERIALS FROM DATE OF ACCEPTANCE BY AAFES. (ALSO SEE MECHANICAL SPECIFICATIONS FOR ADDITIONAL WARRANTY REQUIREMENTS.) GENERAL CONTRACTOR'S WARRANTY MUST ALSO INCLUDE LABOR WHEN
MANUFACTURER'SWARRANTY IS "PARTS ONLY."
10. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE RECEIPT OF ALL AAFES SUPPLIED MATERIALS AND EQUIPMENT. GENERAL CONTRACTOR SHALL NOTIFY AAFES IF ANY MATERIALS OR EQUIPMENT HAS NOT ARRIVED AT THE JOB SITE IN A TIMELY MANNER. ALL SHIPMENTS SHALL BE INSPECTED UPON ARRIVAL FOR DAMAGES, SHORTAGES AND INCORRECT MATERIALS. ALL PROBLEMS SHALL BE REPORTED TO AAFES' PURCHASING DEPARTMENT IMMEDIATELY. GENERAL CONTRACTOR SHALL NOTIFY THE CARRIER IMMEDIATELY OF ALL DAMAGES AND/ORSHORTAGES AND OBTAIN A RECEIPT FOR SUCH. AT THE COMPLETION OF THE PROJECT, GENERAL CONTRACTOR SHALL NOTIFY OWNER'S PURCHASING DEPARTMENT OF ANY SURPLUS EQUIPMENT FOR PROPER DISPOSITION.
11. CONTRACTOR PERSONNEL SHALL HAVE VALID, CURRENT I.D.'s. EVERY VEHICLE OF THE CONTRACTOR SHALL OBTAIN A BASE PASS.
12. GENERAL CONTRACTOR SHALL COORDINATE ALL TRADES NECESSARY TO COMPLETETHE WORK OUTLINED IN THESE DOCUMENTS
13. AT THE COMPLETION OF THE PROJECT, GENERAL CONTRACTOR SHALL PROVIDE ONE(1) EXTRA CARTON OF EACH CEILING TILE AND CERAMIC TILE USED.
14. DUE TO THE NATURE OF THE WORK, ALL DIMENSIONS SHOWN SHALL BE CONSIDERED APPROXIMATE. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS PRIOR TO BEGINNING CONSTRUCTION. SHOP DRAWINGS SHALL BE SUBMITTED TO ARCHITECT FOR APPROVAL PRIOR TO FABRICATION OR INSTALLATION OF ANY ITEM.
FAILURE TO ADHERE TO THIS PROCEDURE SHALL PLACE FULL RESPONSIBILITY FOR ANY ERRORS DIRECTLY UPON THE CONTRACTOR. THE DRAWINGS ARE NOT TO BE SCALED. IF RELEVANT DIMENSIONS ARE OMITED, THEY SHALL BE ADDRESSED BY AN RFI TO THE OWNER/ ARCHITECT AGREEMENT.
15. DRAWINGS ARE NOT TO BE SCALED. IF RELEVANT DIMENSIONS ARE OMITTED, THEY SHALL BE ADDRESSED BY AN RFI TO THE OWNER / OWNER’S ARCHITECT.
16. ARCHITECT WILL NOT HAVE CONTROL OVER OR CHARGE OF AND WILL NOT BERESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCESOR PROCEDURES OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTIONWITH THE WORK, SINCE THESE ARE SOLELY THE CONTRACTOR'S RESPONSIBILITY. ARCHITECT WILL NOT BE RESPONSIBLE FOR CONTRACTOR'S FAILURE TO CARRY OUT THE WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. THE ARCHITECT WILL NOT HAVE CONTROL OR CHARGE OF AND WILL NOT BE RESPONSIBLE FOR ACTS OR OMISSIONS OF THE CONTRACTOR, SUBCONTRACTORS OR THEIR AGENTS OR EMPLOYEES, OR OF ANY OTHER PERSONS PERFORMING PORTIONS OF THE WORK.
17. THERE ARE UNDERGROUND UTILITIES ON THE SITE NEAR OR IN THE AREA OF NEW CONSTRUCTION. CONTRACTOR TO OBTAIN AN APPROVED DIGGING PERMIT (AF FORM 103) PRIOR TO ANY SITE WORK.GENRAL CONTRACTOR TO CALL THE POST DPW AND AAFES PM BEFORE STARTING ANY WORK.
18. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE CAUSED TO EXISTING COMMUNICATIONS FACILITIES AND WILL BE RESPONSIBLE FOR REPAIR OF DAMAGED FACILITIES AT NO COST TO THE GOVERNMENT. IF ANY COMMUNICATIONS CABLES SHOULD BE DAMAGED, CALL THE BASE COMMUNICATION, POST DPW, AND AAFES PM.
19. NO MODIFICATION OF THE EXISTING FIRE SPRINKLER SYSTEM IS ANTICIPATED. IF ANY MODIFICATION IS REQUIRED TO THE FIRE SPRINKLER SYSTEM, THE MODIFICATION MUST BE DESIGNED BY A PROFESSIONAL FIRE PROTECTION ENGINEER. ANY AND ALL SPRINKLER MODIFICATION DOCUMENTS, INCLUDING DRAWINGS, DESIGN ANALYSIS, ETC. MUST BE STAMPED OR SIGNED BY THE REGISTERED PROFESSIONAL FIRE PROTECTION ENGINEER AND SUBMITTED FOR
REVIEW AND,APPROVAL. SEE NOTE 21.
20. ALL DISCIPLINES (ARCHITECTURAL, ELECTRICAL, MECHANICAL, PLUMBING, FIRE SAFETY, ETC) HAVE INFORMATION THROUGHOUT THE ENTIRE SET OF DOCUMENTS
(DRAWINGS AND SPECIFICATIONS).
21. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR THE PROVISION AND INSTALLATION OF ALL WORK INDICATED IN THESE DRAWINGS AND WORK TO INSTALL ALL ITEMS, REGARDLESS OF LOCATION IN THE DRAWINGS OR SPECIFICATIONS, UNLESS SPECIFICALLY NOTED FOR THESE ITEMS AND WORK TO BE PROVIDED AND/OR
INSTALLED BY OTHERS.
22. THE GENERAL CONTRACTOR IS ALSO RESPONSIBLE FOR ALL DEMOLITION, CUTTING, PATCHING, AND RESTORATION OF EXISTING MATERIALS REQUIRED TO INSTALL ALL ITEMS AND WORK INDICATED IN THE DOCUMENTS WHETHER OR NOT DEMOLITION IS INDICATED TO INSTALL THESE ITEMS AND WORK
23. ALL LIGHTING FIXTURES ARE TO BE SUPPLIED AND INSTALLED BY THE G.C. REFER TO THE MEP DRAWINGS AND SPECIFICATIONS AND THE SEATING CONCEPTS
DRAWINGS FOR LIGHTING INFORMATION
24. REFER TO THE DRAWINGS FROM SEATING CONCEPTS, INC. FOR INTERIOR FLOOR AND WALL FINISHES, FURNISHINGS, AND LAYOUT. THE SCI DRAWINGS WERE NOT PREPARED UNDER THE SUPERVISION OF QUORUM ARCHITECTS, INC AND AS SUCH, QUORUM ARCHITECTS, INC. IS NOT RESPONSIBLE FOR THE ACCURACY OF THE INFORMATION PROVIDED BY SCI, THE OWNER, OR THE OWNER’S CONSULTANTS AND VENDORS. ANY DISCREPANCIES BETWEEN THE ARCHITECTURAL AND/OR MEP
DRAWINGS AND THE SEATING CONCEPTS DRAWINGS SHALL BE ADDRESSED WITH AN RFI.
25. GC IS RESPONSIBLE FOR REMOVAL, STORAGE, CLEANING, REINSTALLATION AND CONNECTION OF ALL EQUIPEMENT AND FURNITURE REQUIRING REMOVAL TO ACCOMPLISH THE WORK IN THESE DOCUMENTS. ALL EQUIPMENT INDICATED TO BE REMOVED, RELOATED, OR REPLACED IS TO BE REMOVED BY THE GC, CLEANED AND STORED, UNTILL REISTALLATION, OR IF THE EQUIPMENT IN QUESTION IS TO BE REPLACED, THE GC IS TO OFFER THE EXCHANGE FIRST RIGHT OF REFUSAL OR DISPOSE OF THIS EQUIPMENT AS DIRECTED. ANY REFRIGERANT RECOVEY IS TO BE BY THE GC AND ACCORDING TO LOCAL, STATE, AND FEDERAL
LAWS.
26. GC TO MAINTAIN THE CURRENT WARRANTY ON THE EXISTING ROOF. THE GC IS TO CONTACT THE BASE AND SEE IF THEY HAVE A BASE WARRANTY CONTRACTOR AND TO USE THAT CONTRACTOR FOR ALL ROOF WORK TO MAINTAIN THE ROOF WARRANTY. COORDINATE THIS WITH THE BASE ENGINEERING DEPARTMENT.
27. ALL ROOF, KITCHEN, AND OTHER EQUIPMENT TO BE REMOVED, STORED, CLEANED AND INSTALLED BY GENERAL CONTRACTOR.
28. GC IS RESPONSIBLE FOR ALL REQUIRED SHORING AND BRACING DURING DEMOLITION.
A T
T S
X
ETE
FO
S A
14 3 0 5
R E
G
IS
TERED ARCH
IT
E
C T
D A
V
ID
G. DUM
A
N
SCALE:
AAFES Project Number:
DATE:
SHEET:
PROJECT NUMBER
DRAWING TITLE:
Design. Spaces. People.
825 W. Vickery Blvd. #100 Fort Worth, Texas 76104
ph. (817) 738-8095
fx. (817) 738-9524 www.qarch.com
DRAWN BY:
CHECKED BY:
PROJECT:
EXCHANGE
EXCHANGE
CONSTRUCTION TYPE:
STORE TYPE:
IMAGE UPGRADE:
4792-22-004
JD
DL
RENOVATION
RESTAURANT
35% SUBMITTAL JD05/19/23
95% SUBMITTAL TM08/25/23
SOLICITATION ISSUE JD01/05/24
DATE REVISION NO & DESCRIPTION BY
/5
/2
:3
:0
A M
G-001
TITLE SHEET
01/05/24
23074
SOLICITATION ISSUE
ARMY & AIR FORCE EXCHANGE SERVICE
BURGER KING
ELMENDORF AFB, AK
ARCHITECTURAL
G-001 TITLE SHEET 01/05/24
G-002 PROJECT INFORMATION 01/05/24
G-003 ACCESSIBILITY GUIDELINES 01/05/24
G-004 ACCESSIBILITY GUIDELINES 01/05/24
G-005 ACCESSIBILITY GUIDELINES 01/05/24
G-006 MANUFACTURES & SUPPLIERS 01/05/24
A-100 3D MODEL VIEWS 01/05/24
AD-103 DEMOLITION SITE PLAN 01/05/24
AS-101 SITE PLAN 01/05/24
AS-102 SITE DETAILS 01/05/24
AD-101 DEMOLITION FLOOR PLAN 01/05/24
AD-102 DEMOLITION RCP 01/05/24
AD-104 DEMOLITION ROOF PLAN 01/05/24
AD-201 DEMOLITION EXTERIOR ELEVATIONS 01/05/24
A-101 FIRST FLOOR PLAN 01/05/24
A-102 REFLECTED CEILING PLAN 01/05/24
A-104 ROOF PLAN 01/05/24
A-201 EXTERIOR ELEVATIONS 01/05/24
A-202 EXTERIOR FINISH SCHEDULE 01/05/24
A-203 EXTERIOR FINISH SCHEDULE 01/05/24
A-301 WALL SECTIONS 01/05/24
A-302 WALL SECTIONS 01/05/24
A-303 SECTION DETAILS 01/05/24
A-304 TYP DEMOLITION WALL SECTIONS 01/23/24
A-401 BID OPTION 2 ENLARGED TOILET PLANS 01/05/24
A-501 PLAN DETAILS 01/05/24
David Duman
2024.02.05 09:17:32-06'00'
POST ROAD GATE - MAIN COMMERCIAL GATE TRUCK ACCESS - OPEN 0600-1800 M-F
RICHARDSON GATE - AFTER HOURS ENTRY LARGE COMMERCAIL VEHICLES
PROJECT SITE
ACC ACCESSIBLE
ACT ACOUSTICAL CEILING
TILE
ADJ ADJUSTABLE
AFF ABOVE FINISHED
FLOOR
ALUM ALUMINUM
APPROX APPROXIMATE
BLKG BLOCKING
BOB BOTTOM OF BEAM
BOH BACK OF HOUSE
BLDG BUILDING
CAB CABINET
CLG CEILING
CLR CLEAR/CLEARANCE
CMU CONCRETE MASONRY
UNIT
CTR CENTER
C.L. CENTER LINE
COL COLUMN
CONC CONCRETE
CONT CONTINUOUS
CONST CONSTRUCTION
CT CERAMIC TILE
CW COLD WATER
DEG DEGREES
DTL DETAIL
DIA DIAMETER
DIM DIMENSION
DISP DISPENSER
DN DOWN
DPW DIRECTORATE OF
PUBLIC WORKS
DWG(S) DRAWING(S)
EA EACH
EC ELECTRICAL
CONTRACTOR ELEV
ELEVATION
ELEC ELECTRICAL
EQUIP EQUIPMENT
EQ EQUAL
EXIST EXISTING
EXP EXPOSED
EXT EXTERIOR
FC FIXTURE
CONTRACTOR
FFE FINISH FLOOR ELEV
FOC FACE OF CABINET
FOG FACE OF GLAZING
FOS FACE OF STUD
FRP FIBERGLASS
REINFORCED PANEL
FIO FURNISHED &
INSTALLED BY OWNER
FOIC FURNISHED BYOWNER
INSTALLED BY
CONTRACTOR
FLR FLOOR
FS FLOOR SINK
FT FOOT/FEET
FV FIELD VERIFY
GA GAUGE
GALV GALVANIZED
GC GENERAL
CONTRACTOR
GWB GYPSUM WALL BOARD
HC HOLLOW CORE
HDR HEADER
HDWD HARDWOOD
HDWR HARDWARE
HM HOLLOW METAL
HORZ HORIZONTAL
HR HOUR
HVAC HEATING
VENTILATING
AIR CONDITIONING
HW HOT WATER
ID INSIDE DIAMETER
IF INSIDE/INTERIOR
FACE
INSUL INSULATION
INFO INFORMATION
JC JOB CAPTAIN
LC LICENSEE
LL LANDLORD
MAX MAXIMUM
MECH MECHANICAL
MC MECHANICAL
CONTRACTOR
MEP MECHANICAL,
ELECTRICAL
AND PLUMBING
MFG MANUFACTURER
MIN MINIMUM
MLDG MOULDING
MTL METAL
NAT NATURAL
NIC NOT IN CONTRACT
NTS NOT TO SCALE
OA OVER ALL
OC ON CENTER
OD OUTSIDE DIAMETER
OF OUTSIDE FACE
OPNG OPENING
PC PLUMBING
CONTRACTOR
PLAM PLASTIC LAMINATE
PLYWD PLYWOOD
PM PROJECT MANAGER
PT PAINT
QT QUARRY TILE
R RADIUS
RCP REFLECTED CEILING
PLAN
REF REFERENCE
REQ('D) REQUIRE(D)
REV REVISED/REVISION
SB STARBUCKS
SC SOLID CORE
SHT SHEET
SIM SIMILAR
SOL SOLID
SPECS SPECIFICATION(S)
SQ SQUARE
SF SQUARE FEET
SS STAINLESS STEEL
STL STEEL
STOR STORAGE
SUSP SUSPENDED
TEL TELEPHONE
TEMP TEMPORARY
3PL THIRD PARTY
LOGISTICS-
TYP TYPICAL
UON UNLESS OTHERWISE
NOTED
VCT VINYL COMPOSITE
TILE
VD VENDOR DIRECT
VERT VERTICAL
VIF VERIFY IN FIELD
WH WATER HEATER
WD WOOD
EF/CI EXCHANGE
FURNISHED/
CONTRCTOR
INSTALLED
EF/EI EXCHANGE
FURNISHED/
EXCHANGE
INSTALLED
CF/CI CONTRACTOR
FURNISHED/
CONTRACTOR
INSTALLED
OCU ORDER
CONFIRMATION UNIT
U.N.O. UNLESS NOTED
OTHERWISE
ABBREVIATIONS
NORTH ARROW
0 1 2 3 4 8 12
CENTER LINE
REVISION CLOUD
SCALE BAR
0'-0"
BENCHMARK
ELEVATION
SECTION
SHEET NUMBER
SECTION NUMBER
DETAIL BUBBLE
SHEET NUMBER
DETAIL NUMBER
xxxx x xxxx x xxxx
PXXX FINISH SCHEDULE
X REVISION
DATUM POINT
AFF HEIGHT TAGS
DOOR NUMBER
EQUIPMENT TAG
WALL TYPE TAG
+X-XX
XXX
XXXX
X
X APPLIED WALL
TREATMENT TAG
RESPONSIBILITY SCHEDULE
ARCHITECTURAL SYMBOLS
A T
T S
X
ETE
FO
S A
14 3 0 5
R E
G
IS
TERED ARCH
IT
E
C T
D A
V
ID
G. DUM
A
N
SCALE:
AAFES Project Number:
DATE:
SHEET:
PROJECT NUMBER
DRAWING TITLE:
Design. Spaces. People.
825 W. Vickery Blvd. #100 Fort Worth, Texas 76104
ph. (817) 738-8095
fx. (817) 738-9524 www.qarch.com
DRAWN BY:
CHECKED BY:
PROJECT:
EXCHANGE
EXCHANGE
CONSTRUCTION TYPE:
STORE TYPE:
IMAGE UPGRADE:
4792-22-004
JD
DL
RENOVATION
RESTAURANT
35% SUBMITTAL JD05/19/23
95% SUBMITTAL TM08/25/23
SOLICITATION ISSUE JD01/05/24
DATE REVISION NO & DESCRIPTION BY
1/2" = 1'-0"
/5
/2
:3
:0
A M
G-002
PROJECT INFORMATION
01/05/24
23074
SOLICITATION ISSUE
ARMY & AIR FORCE EXCHANGE SERVICE
BURGER KING
ELMENDORF AFB, AK
SCALE: 1/2" = 1'-0"G-002
1 CONTRACTOR HAUL ROUTE
ICE MACHINES X X
HME HEADSETS X X
EXTERIOR GRAPHCIS X X
TOILET ACCESSORIES X X
INTERIOR + EXTERIOR FINISHES X X
INCLUDES WINDOW SILL +
CHAIR RAILS
FURNITURE INSTALLATION X X
FURNITURE REMOVAL & DISPOSAL X
DATA WIRING X X PER DOCUMENTS
AWNINGS & CANOPIES X X
NEW EXTERIOR LIGHTING X X
NEW INTERIOR LIGHTING X X UNO PER DOCUMENTS
PLUMBING FIXTURES X X
PLUMBING, HVAC, ELECTRICAL X X PER DOCUMENTS
KITCHEN EQUIPMENT X X
REMOVE & STORE EXISTING
EQUIPMENT
X X PER DOCUMENTS
NEW DRIVE-THRU WINDOWS X X
LANDSCAPE INSTALL & TRIM X X
PARKING LOT STRIPING X X
NEW CONCRETE WALL &
FOUNDATION
X X
ACCESSIBLE TOILET SIGNAGE X X
EXTERIOR MENU BOARD... X X
BUILDING SIGNAGE X X
DRIVE-THRU TIMER X X
DRIVE-THRU LOOP DETECTOR X X
NEW DRIVE-THRU SIGNAGE X X
NEW SITE SIGNAGE X X
REMOVE SITE SIGNAGE X X PER DOCUMENTS
PAVING X X
SITE CONSTRUCTION X X PER DOCUMENTS
SITE DEMOLITION X X PER DOCUMENTS
EXISTING CONDITIONS &
DEMOLITION
X X SPEC, DIVISION 2
GENERAL REQUIREMENTS X X SPEC, DIVISION 1
F U
R N
IS
H
E D
IN
S
T A
L L E
D
F U
R N
IS
H
E D
IN
S
T A
L L E
D
F U
R N
IS
H
E D
IN
S
T A
L L E
DBURGER KING
GC EXCHANGE
EXCHANGE
VENDOR
REMARKS
RESPONSIBILITY SCHEDULE 02/05/2024
A T
T S
X
ETE
FO
S A
14 3 0 5
R E
G
IS
TERED ARCH
IT
E
C T
D A
V
ID
G. DUM
A
N
SCALE:
AAFES Project Number:
DATE:
SHEET:
PROJECT NUMBER
DRAWING TITLE:
Design. Spaces. People.
825 W. Vickery Blvd. #100 Fort Worth, Texas 76104
ph. (817) 738-8095
fx. (817) 738-9524 www.qarch.com
DRAWN BY:
CHECKED BY:
PROJECT:
EXCHANGE
EXCHANGE
CONSTRUCTION TYPE:
STORE TYPE:
IMAGE UPGRADE:
4792-22-004
JD
DL
RENOVATION
RESTAURANT
35% SUBMITTAL JD05/19/23
95% SUBMITTAL TM08/25/23
SOLICITATION ISSUE JD01/05/24
DATE REVISION NO & DESCRIPTION BY
/5
/2
:3
:0
A M
G-003
ACCESSIBILITY
GUIDELINES
01/05/24
23074
SOLICITATION ISSUE
ARMY & AIR FORCE EXCHANGE SERVICE
BURGER KING
ELMENDORF AFB, AK
T S
X
ETE
FO
S A
14 3 0 5
R E
G
IS
TERED ARCH
IT
E
C T
D A
V
ID
G. DUM
A
N
SCALE:
AAFES Project Number:
DATE:
SHEET:
PROJECT NUMBER
DRAWING TITLE:
Design. Spaces. People.
825 W. Vickery Blvd. #100 Fort Worth, Texas 76104
ph. (817) 738-8095
fx. (817) 738-9524 www.qarch.com
DRAWN BY:
CHECKED BY:
PROJECT:
EXCHANGE
EXCHANGE
CONSTRUCTION TYPE:
STORE TYPE:
IMAGE UPGRADE:
4792-22-004
JD
DL
RENOVATION
RESTAURANT
35% SUBMITTAL JD05/19/23
95% SUBMITTAL TM08/25/23
SOLICITATION ISSUE JD01/05/24
DATE REVISION NO & DESCRIPTION BY
/5
/2
:3
:0
A M
G-004
ACCESSIBILITY
GUIDELINES
01/05/24
23074
SOLICITATION ISSUE
ARMY & AIR FORCE EXCHANGE SERVICE
BURGER KING
ELMENDORF AFB, AK
T S
X
ETE
FO
S A
14 3 0 5
R E
G
IS
TERED ARCH
IT
E
C T
D A
V
ID
G. DUM
A
N
SCALE:
AAFES Project Number:
DATE:
SHEET:
PROJECT NUMBER
DRAWING TITLE:
Design. Spaces. People.
825 W. Vickery Blvd. #100 Fort Worth, Texas 76104
ph. (817) 738-8095
fx. (817) 738-9524 www.qarch.com
DRAWN BY:
CHECKED BY:
PROJECT:
EXCHANGE
EXCHANGE
CONSTRUCTION TYPE:
STORE TYPE:
IMAGE UPGRADE:
4792-22-004
JD
DL
RENOVATION
RESTAURANT
35% SUBMITTAL JD05/19/23
95% SUBMITTAL TM08/25/23
SOLICITATION ISSUE JD01/05/24
DATE REVISION NO & DESCRIPTION BY
/5
/2
:3
:0
A M
G-005
ACCESSIBILITY
GUIDELINES
01/05/24
23074
SOLICITATION ISSUE
ARMY & AIR FORCE EXCHANGE SERVICE
BURGER KING
ELMENDORF AFB, AK
T S
X
ETE
FO
S A
14 3 0 5
R E
G
IS
TERED ARCH
IT
E
C T
D A
V
ID
G. DUM
A
N
SCALE:
AAFES Project Number:
DATE:
SHEET:
PROJECT NUMBER
DRAWING TITLE:
Design. Spaces. People.
825 W. Vickery Blvd. #100 Fort Worth, Texas 76104
ph. (817) 738-8095
fx. (817) 738-9524 www.qarch.com
DRAWN BY:
CHECKED BY:
PROJECT:
EXCHANGE
EXCHANGE
CONSTRUCTION TYPE:
STORE TYPE:
IMAGE UPGRADE:
4792-22-004
JD
DL
RENOVATION
RESTAURANT
35% SUBMITTAL JD05/19/23
95% SUBMITTAL TM08/25/23
SOLICITATION ISSUE JD01/05/24
DATE REVISION NO & DESCRIPTION BY
/5
/2
:3
:0
A M
G-006
MANUFACTURES &
SUPPLIERS
01/05/24
23074
SOLICITATION ISSUE
ARMY & AIR FORCE EXCHANGE SERVICE
BURGER KING
ELMENDORF AFB, AK
MOSS RETAIL AND ENVIRONMENTS
(GRAPHICS)
2643 WEST CHICAGO AVE CHICAGO, IL 60622
bk@mossinc.com Scott Metzger 847.238.4245 smetzger@mossinc.com
LSI INDUSTRIES (GRAPHICS)
10000 ALLIANCE ROAD
CINCINNATI, OH. 45242
BOB LUCAS 480‐368‐9399 OR 602‐740‐9894
Bob.Lucas@LSI‐INDUSTRIES.com
PLAY SYSTEMS/SII (SUPERIOR PLAY
SYSTEMS) (PLAYGROUND MANUFACTURER)
1050 COLUMBIA DR.
CARROLLTON, GA 30717 SHAN MCGUIRE
678‐390‐1915 https://superiorplay.com/
SOFT PLAY, LLC
(PLAYGROUND MANUFACTURER, SAFETY
SURFACING, NON‐CONTAINED PLAY
EQUIPMENT)
13620 EAST REESE BLVD. SUITE 300
HUNTERSVILLE, NC. 28078 BROCK HODGE
704‐948‐3430 brock.hodge@softplay.com
VGS, INC (GRAPHICS)
1696 MABRY MILL DRIVE, SW NORTH
CANTON, OH 44709
BURGERKING@VGS‐INC.COM (800)201‐0301 x1
FINGERSAFE USA, INC.
(FINGER IN JAMB SAFETY ‐ PLAYGROUNDS) 115
WEST OGLETHORPE AVENUE SAVANNAH, GA
31401 orders@fingersafe.com
MEAGAN KUJAWSKI 912‐234‐6120
Meagan@Fingersafe.com
DAKTRONICS, INC (DIGITAL READERBOARD)
210 DAKTRONICS DRIVE
BROOKINGS, SD 57006
GREG BREYFOGLE 407‐310‐3695
Greg.Breyfogle@daktronics.com
OPTEC DISPLAYS, INC (DIGITAL
READERBOARD) 1700 SOUTH DESOTO PLACE
ONTARIO, CA 91768
Chad Engstrom (626)252‐8333 cengstrom@optec.com
KONTECHUSA
(INTERIOR AND EXTERIOR BUILDING
LIGHTING) 18045 ROLAND STREET
CITY OF INDUSTRY, CA 91748 (866) 236‐8701
Miguel Martinez (626)622‐1325 mmartinez@kontechusa.com
HILL PHOENIX POWER SYSTEMS DIVISION
(FACTORY INTEGRATED SWITCH GEAR) 8166
INDUSTRIAL BLVD
COVINGTON, GA. 30014
dfr‐info@doverfoodretail.com 770‐285‐3264
HOSHIZAKI AMERICA (ICE MACHINES)
618 HIGHWAY 74 SOUTH PEACHTREE CITY,
GA 30269
ANGIE WARREN (770)487‐2331 x11329 adwarren@hoshizaki.com
SCOTSMAN ICE SYSTEMS (ICE MACHINES)
775 CORPORATE WOODS PARKWAY VERNON
HILLS, IL 60061
Evolution Team (800)726‐8762 x15204 team.resolution@scotsman‐ice.com
APA COLOR GRAPHICS
(LIMITED DECOR ITEMS & GRAPHICS) 2929
PACIFIC DRIVE
NORCROSS, GA 800.543.5775
CHUCK BOGEL 404.355.1355
chuck@apacolorgraphics.com
HAMILTON PARKER COMPANY
(HOLLOW METAL FRAMES & DOORS, WOOD
DOORS, HARDWARE (HINGES, LOCKS, ETC)
1865 LEONARD AVENUE
COLUMBUS, OH 43219
JIM CAMPBELL 614‐358‐7806
jimcampbell@hamiltonparker.com
3M COMMERCIAL CORE DIVISION
(WINDOW FILM)
3M CENTER ST. PAUL, MN
JOE CIAMPI: 704‐771‐2449 OR 800‐328‐0033
jjciampi@mmm.com
NRS ‐ NATIONAL READERBOARD SUPPLY
(READERBOARD LETTERS & SUPPLIES) 160
PAHLONE PARKWAY
PONCHA SPRINGS, CO 81242
Patrick Case 800‐243‐6676 Sales@nationalreaderboard.com
FEDERAL HEATH SIGN CO (CANOPIES AND
SIGNS) 12704 DUPONT CIRCLE
TAMPA FL 33626
FIONA PAUL 813‐855‐4415
fpaul@federalheath.com
CREE LIGHTING
(INTERIOR AND EXTERIOR LIGHTING,
SURVEYS AND PHOTOMETRICS)
9201 WASHINGTON AVENUE
RACINE, WI 53406
ELVIR SULJIC 262‐884‐3332
esuljic@creelighting.com
VAOPTO, LLC
(INTERIOR AND EXTERIOR BUILDING
LIGHTING) 5178 WEST PATRICK LANE
LAS VEGAS, NV 89188 Linda Xu (702)517‐5789 linda@vaopto.com
MANITOWOC ICE (ICE MACHINES)
2110 SOUTH 26TH STREET MANITOWOC, WI
54221 JOAN SALAH 813‐504‐9262
Joan.Salah@welbilt.com
KOLPAK, A WELBILT COMPANY (WALK‐IN
COOLERS / FREEZERS) 952 KISSWICH MANOR
LANE BALDWIN, MO 63011
JOAN SALAH 813‐504‐9262
Joan.Salah@welbilt.com
WAUSAU TILE, INC
(EXTERIOR DÉCOR FURNITURE &
ACCESSORIES)
P.O. BOX 1520 WAUSAU, WI 54402
RACHEL BATHKE 715‐241‐0320
RRBathke@wausautile.com
READY ACCESS
(DRIVE THRU WINDOWS & AIR CURTAINS) 1815
ARTHUR DRIVE WEST
CHICAGO, IL. 60185
KELLY MCGOLDRICK: 800‐621‐5045 EXT 113
kelly@ready‐access.com
COMMERCIAL INTERIORS
MANUFACTURING (RESTROOM
PARTITIONS, HOLLOW METAL FRAMES &
DOORS, HARDWARE (HINGES, LOCKS,
ETC)
158 HOLLY STREET
JASPER, GA 30143
AUSTIN HOLAN: 706.299.0327
austin@cimgbiz.com
ENTERA SIGNS (CANOPIES AND SIGNS) 1200
ENTERA DRIVE PANAMA CITY, FL. 32401
MATT CZAJKOWSKI 850‐691‐9652
matt.czajkowski@enterabranding.com
CUMMINGS SIGNS, INC (CANOPIES AND
SIGNS) 105 DALTON PLACE WAY KNOXVILLE,
TN 37912 JOEL EFFLER 615‐872‐5483
joel.effler@cummingssigns.com
LSI INDUSTRIES INC.
(INTERIOR AND EXTERIOR LIGHTING,
SURVEYS AND PHOTOMETRICS)
10000 ALLIANCE ROAD
CINCINNATI, OH. 45242
BOB LUCAS 480‐368‐9399 OR 602‐740‐9894
Bob.Lucas@LSI‐INDUSTRIES.com
ENERGYWISE SOULUTIONS, LLC
(MASTER LIGHTING CONSOLIDATOR,
SURVEYS AND PHOTOMETRICS)
8550 UNITED PLAZA BOULEVARD, SUITE 702
BATON ROUGE, LA 70809
JENNIFER WADDICK 877‐225‐1336
jennifer@energywisemail.com
INTERNATIONAL COLD STORAGE (ICS)
(WALK‐IN COOLERS / FREEZERS, DRY
STORAGE COMPARTMENTS)
215 EAST 13th STREET ANDOVER, KS. 67002
LYNNE CLATTERBUCK 316‐218‐4126
Lynne.clatterbuck@icsco.com
TAYLOR ULTIMATE SERVICES, INC
(SHAKE MACHINE, FROZEN BEVERAGE
MACHINE) 1780 NORTH COMMERCE PKWY
WESTON, FL. 33326
RJ PIEDRA: 954‐217‐9100
raul@taylorus.com
TWENTY FOUR 7 GLOBAL SOLUTIONS, INC.
(GARDEN GRILL, PRIME & ROYAL CHAIRS
AND BARSTOOLS)
898 NORTH SEPULVEDA BLVD, SUITE 465 EL
SEGUNDO, CA 90245
GIANNE WON 323‐319‐2727
gianne.won@twentyfour7‐global.com
QUIKSERV
(DRIVE‐THRU WINDOWS & AIR CURTAINS) 11441
BRITTMOORE PARK DRIVE HOUSTON, TX. 77041
800‐388‐8307
BRIAN MCCLOSKEY
bmccloskey@quikserv.com
MARLITE
(RESTROOM PARTITIONS, ALUMINUM
FRAMES & DOORS, DOOR HARDWARE,
(HINGES, LOCKS, ETC)
202 HARGER STREET
DOVER, NH 44622 800‐377‐1221
ANITA CRAIG 330‐260‐7621
acraig@Marlite.com
ALLEN INDUSTRIES, INC (CANOPIES AND
SIGNS) 11351 49TH STREET NORTH
CLEARWATER, FL 33762 ALAN BRYANT
336‐317‐0195 Alan.Bryant@allenindustries.com
LEKTRON, INC
(LED PARAPET LIGHT BANDS) 4111 S. 74th E.
Ave.
TULSA, OK. 74145
ERIC PYLE 918‐622‐4978
BurgerKing@LektronInc.com
SECURITY LIGHTING SYSTEMS
(FULL STORE PACKAGE LIGHTING FOR
INTERIOR/EXTERIOR BUILDING & SITE
LIGHTS, SURVEYS AND PHOTOMETRICS) 2100
GOLF ROAD, SUITE 460
ROLLING MEADOWS, IL. 60008
WHITNEY WATSON: 800‐544‐4848 EXT 131
wilg@securitylighting.com
HERMITAGE LIGHTING NATIONAL
ACCOUNTS (MASTER LIGHTING
CONSOLIDATOR, SURVEYS AND
PHOTOMETRICS)
3640 TROUSDALE DRIVE
NASHVILLE, TN. 37204
WYATT CULVER (615) 843‐3379
wculver@gohermitage.com
DIVISION 8 ‐ DOORS AND WINDOWS DIVISION 10 ‐ SIGNS & CANOPIES DIVISION 16 ‐ ELECTRICAL CORNELIUS, INC. (BEVERAGE SYSTEM)
101 BROADWAY STREET WEST OSSEO, MN 55369
ROSS DAVIS: 630‐659‐8690
ross.davis@cornelius.com
Customer 1st LLC (SAFES)
8899 EAST DAILY ROAD, SUITE #51
PEKIN, IN 47165
MIKE MARCOSA ‐877‐768‐9970
mike@customer1stsafes.com
ECOLAB FOOD SAFETY SPECIALTIES INC,
DBA DAYDOTS (FIRST AID KITS)
201 EAST JOHN CARPENTER FREEWAY
IRVING, TX 75062
ANNA MALHIS 800‐321‐3687
customercare@daydots.com
FRYMASTER CORPORATION (FRYERS)
8700 LINE AVE
SHREVEPORT, LA 71106 JOAN SALAH
813‐504‐9262 Joan.Salah@welbilt.com
LANCER CORP. (BEVERAGE SYSTEM) 6655
LANCER BLVD
SAN ANTONIO, TX. 78219
GREG EDWARDS: 817‐692‐5094
greg.edwards@lancercorp.com
NAUTICAL FURNISHINGS, LLC (LIMITED
DÉCOR ITEMS)
60 NW 60TH STREET
FT. LAUDERDALE, FL 33309 MICHAEL
HOGLUND: 954‐771‐1100
mhoglund@nauticalfurnishings.com
NICHIHA USA LLC (FIBERCEMENT PANELS)
6465 EAST JOHNS CROSSING, SUITE 250 JOHNS
CREEK, GA 30097
NICHIHA CUSTOMER SERVICE (770) 805‐9466
BK@NICHIHA.COM
H&K INTERNATIONAL
(STAINLESS STEEL BATHROOM SINKS) 2200
SKYLINE DRIVE
MESQUITE, TX 75149
HEATHER VALVERDE 214‐818‐3521
heather.valverde@hki.com
ZURN INDUSTRIES (PLUMBING FIXTURES)
CONTACT:
HAINES, JONES, AND CADBURY
or RESTROOM REMODELS COMPANY
H&K INTERNATIONAL
(BROILER AND FRYER VENTILATION HOODS)
2200 SKYLINE DRIVE
MESQUITE, TX 75149
HEATHER VALVERDE 214‐818‐3521
heather.valverde@hki.com
GAYLORD INDUSTRIES, INC
(BROILER AND FRYER VENTILATION HOODS)
10900 SOUTHWEST AVERY STREET TUALATIN,
OR, 97062
ROB CARMICHAEL 770‐265‐2562
Rob.Carmichael@gaylordventilation.com
TRIMARK USA
(KITCHEN EQUIPMENT CONSOLIDATOR,
SMALLWARES FOR AAFES ORDERS ONLY)
2601 HOPE CHURCH ROAD WINSTON‐SALEM,
NC 27103 BILLY HIGH 336‐354‐4262
billy.high@trimarkusa.com
PITCO FRIALATOR (FRYERS)
10 FERRY STREET
CONCORD, NH. 03301
MARK MCCABE: 603‐230‐5509
MMcCabe@pitco.com
SEATING CONCEPTS (DECOR)
125 CONNELL STREET
ROCKDALE, IL. 60436 (815)730‐7980
ZACH DEPYSSLER
zdepyssler@seating‐concepts.com
FIRESTONE METAL PRODUCTS (METAL ROOF)
250 WEST 96TH STREET INDIANAPOLIS, IN 46260
YUSUKE KOREEDA: 615‐345‐9991
koreedayusuke@firestonebp.com
G.A.F.
(FLAT ROOF) 1361 ALPS ROAD
WAYNE, NJ. 07470
(201) 628‐3000 800‐766‐3411
SAN JAMAR
(KITCHEN PAPER TOWEL DISPENSORS &
SUPPLIES) 555 KOOPMAN LANE
ELKHORN, WI. CONTACT: FRANKE, INC.
H&K INTERNATIONAL QUALSERV
SOLUTIONS
WORLD DRYER, CO (HAND DRYERS)
CONTACT:
HAINES, JONES, & CADBURY (HJC)
RESTROOM REMODELS COMPANY
HAMILTON PARKER
FRANKE, INC.
(BROILER AND FRYER VENTILATION HOODS)
800 AVIATION PARKWAY
SMYRNA, TN 37086 800‐877‐5718
fs‐bkparts.us@franke.com
AMEREX CORPORATION (FIRE PROTECTION
SYSTEMS) 7595 GADSDEN HIGHWAY
TRUSSVILLE, AL 35173‐0081
JAMES KNOWLES 205‐655‐5721
james.knowles@amerex‐fire.com www.amerex‐fire.com
H & K INTERNATIONAL
(KITCHEN EQUIPMENT CONSOLIDATOR,
SMALLWARES, HOODS)
2200 SKYLINE DR
DALLAS, TX 75223
HEATHER VALVERDE 561‐626‐1020
heather.valverde@hki.com
NIECO CORPORATION (BROILERS)
7950 CAMERON DRIVE
WINDSOR, CA 95492 GUIDO NAVA 630‐303‐6824
gnava@nieco.com
FACILITY CONCEPTS, INC (FCI) (DECOR)
7676 ZIONSVILLE ROAD
INDIANAPOLIS, IN 46268 (800)915‐8890
customerservice@fcius.com KEN WEAVER kweaver@fcius.com
BERRIDGE ROOFING (METAL ROOF) TYLER
HALL
SAN ANTONIO, TX. 210‐650‐7047
TAMKO ROOFING PRODUCTS (FLAT
ROOFING)
P.O. BOX 1404 JOPLIN, MO. 64802
800‐641‐4691
AMERICAN STANDARD (RESTROOM
ACCESSORIES) 1 CENTENNIAL AVENUE
PISCATAWAY, NJ. 08854 CONTACT:
HAINES, JONES, & CADBURY (HJC)
RESTROOM REMODELS COMPANY
HAMILTON PARKER
HAMILTON PARKER COMPANY
(RESTROOM PLUMBING & ACCESSORIES,
HIGH CHAIRS) 1865 LEONARD AVENUE
COLUMBUS, OH 43219
JIM CAMPBELL 614‐358‐7806
jimcampbell@hamiltonparker.com
TRANE
(AIR CONDITIONING UNITS, RTU's/SPLIT
SYSTEMS CONTROLS)
2884 CORPORATE WAY
MIRAMAR, FL. 33025
CHRIS ST. JOHN 407‐325‐7123
bkhvac@trane.com
LOREN COOK CO (EXHAUST FANS) 2015 E.
DALE
SPRINGFIELD, MO 65803‐4637 BRENT
FULLERTON 417‐869‐6474
bfullerton@lorencook.com
QUALSERV SOLUTIONS
(KITCHEN EQUIPMENT CONSOLIDATOR,
SMALLWARES) 7400 SOUTH 28th STREET
FORT SMITH, AR. 72908
BRITTANY GOODWIN (479)646‐8386 x335 BGoodwin@qualservsolutions.com
DUKE MANUFACTURING
(BROILERS & PRODUCT HOLDING UNITS) 2305
NORTH BROADWAY
ST. LOUIS MO. 63102
RICK GARRIGA 306‐606‐2084
rgarriga@dukemfg.com
FCC COMMERCIAL FURNITURE (INTERIOR
& EXTERIOR DÉCOR) 8452 OLD HWY. 99
NORTH
ROSEBURG, OR. 97470 PRESTON O'HARA
800‐322‐7328 EXT 284
preston.ohara@fccfurn.com
DURO‐LAST ROOFING (FLAT ROOFING)
525 MORLEY DRIVE
SAGINAW, MI 48601
nationalaccounts@duro‐last.com 800‐432‐9331
BASF CORPORATION (POLYURETHANE
ROOFING SYSTEMS) 1703 CROSS POINT
AVE
HOUSTON, TX 77054
ANDREW FOPPE (980) 218‐1894
andrew.foppe@basf.com
DIVISION 7 ‐ THERMAL MOISTURE PROTECTION HAINES, JONES, AND CADBURY (HJC)
(RESTROOM PLUMBING & ACCESSORIES,
TOLIET
PARTITIONS, CORIAN SINKS, WATER
HEATERS, HIGH CHAIRS)
310 SW 24TH STREET BENTONVILLE, AR 72712
bk@hjcinc.com OR 800‐459‐7099
RESTROOM REMODELS COMPANY
(RESTROOM PLUMBING & ACCESSORIES,
CORIAN SINKS) 15 HAMMATT STREET
IPSWICH, MA 01938
Krislynn Maciel 978‐525‐0008 kris@restroomremodels.com
ECOLAB
(WATER FILTERS)
1801 RIVERBEAND WEST DRIVE FORT
WORTH, TX 76118
AL POWELL 816‐206‐2513
al.powell@ecolab.com
CARRIER CORPORATION (AIR
CONDITIONING) 6304 CARRIER PARKWAY
SYRACUSE, NY. 13221
KEN REVILLA 954‐218‐0070
Ken.revilla@carrier..com
HM ELECTRONICS, INC (HME) (DRIVE THRU
HEADSETS) 14110 STOWE DRIVE
POWAY, CA. 92064 STEVE LEE 858‐848‐3704
SLee@hme.com
FRANKE
(KITCHEN EQUIPMENT CONSOLIDATOR,
SMALLWARES, HOODS)
800 AVIATION PARKWAY
SMYRNA, TN. 37086
CUSTOMER SERVICE: 800‐877‐5178
fs‐bkparts.us@franke.com JOHN EDMONDS 615‐267‐1563 john.edmonds@franke.com
ELKAY SYSTEMS (FORMERLY ISI) (DECOR)
241 NORTH BROADWAY, SUITE 600
MILWAUKEE, WI 53202
CHRISTINA GUTIERREZ 414.847.0709
christina.gutierrez@elkay.com
ADDISON STEEL (STRUCTURAL STEEL) ADDISON, IL
256‐747‐1554
REDBUILT TRUSSES
(PRE‐FABRICATED ENGINEERED TRUSSES)
Delaware, OH 43015
JARVIS JACKSON 740‐368‐4229
jjackson@redbuilt.com
BOBRICK/KOALA KARE PRODUCTS
(RESTROOM ACCESSORIES, TOILET
PARTITIONS & HARDWARE, BABY CHANGING
TABLES & HIGHCHAIRS) CONTACT:
HAINES, JONES, & CADBURY (HJC)
RESTROOM REMODELS COMPANY
HAMILTON PARKER
SPROVERI'S CUSTOM COUNTERS (CORIAN
VANITY SINKS)
55 LAURA DRIVE
ADDISON, IL 60101 CONTACT:
HAINES, JONES, & CADBURY (HJC)
RESTROOM REMODELS COMPANY
DIVISION 5 ‐ METALS DIVISION 6 ‐ WOODS, COMPOSITES DIVISION 10 ‐ SPECIALTIES 3M FOOD SERVICE (WATER FILTERS) 3M
CENTER
BLDG. 223‐2N‐20
ST. PAUL, MN. 55144‐1000 DAVID RADCLIFF
518‐281‐7754 dpradliff@mmm.com foodservice@mmm.com
ANTUNES (WATER FILTERS)
180 KEHOE BOULEVARD CAROL STREAM, IL
60188 SUSAN SUTTER 630‐784‐3447
susan.sutter@antunes.com
LG ELECTRONICS
(INTERIOR & OUTDOOR DIGITAL MENU
BOARD SCREENS) 2000 MILLBROOK DRIVE
LINCOLNSHIRE, IL 60069 MICHAEL HA
847‐941‐8855 michael1.ha@lge.com
3M FOOD SERVICE BUSINESS (DRIVE THRU
HEADSETS)
3M CENTER BLDG. 223‐2N‐20
ST. PAUL, MN. 55144‐1000 JOE CIAMPI:
704‐771‐2449 jjciampi@mmm.com
CHARTER HOUSE INC. (INTERIOR &
EXTERIOR DÉCOR) 4660 136 AVENUE
HOLLAND, MI. 49424 800‐314‐7659
KEITH LEBERT 248‐996‐0315
keith.lebert@charter‐house.com
HC MUDDOX BRICK CO. (FACE BRICK)
4875 BRADSHAW ROAD
SACRAMENTO, CA 95827 ERIN LYNCH
916‐206‐7831
BORAL STONE
(MANUFACTURED STACKED STONE) 1370
GRAND AVENUE, SUITE B
SAN MARCOS, CA 92078 SUSAN KING (413)
207‐7285 Susan.King@boral.com culturedstone@boral.com
ARMSTRONG STRATEGIC ACCOUNTS
(CEILING TILE)
CHERYL SMITH 252‐214‐4426
cbsmith@armstrongceilings.com
OR ARMSTRONG STRATEGIC ACCOUNTS (800)
442‐4212 armstrongcsa@armstrongceilings.com
USG INTERIORS (CEILING TILE)
JOHN FUNES 312.436.5841 JFUNES@USG.COM
NOTE: USE PROGRAM QUOTE # 00103139 TO
RECEIVE NATIONAL BKC PRICING
RHEEM
(WATER HEATERS)
RHEEM NATIONAL ACCOUNT PRICING
THROUGH HAINES, JONES, & CADBURY
bk@hjcinc.com OR 800‐459‐7099
SELECTO SCIENTIFIC, INC (WATER FILTERS)
3980 LAKEFIELD COURT
SUWANEE, GA. 30024
CUSTOMER SERVICE (800)635‐4017 x3
Samsung/LSI
(INTERIOR & OUTDOOR DIGITAL MENU
BOARD SCREENS) 10000 ALLIANCE ROAD
CINCINNATI, OH 45242
DAVID WATFORD 850‐826‐4602
d.watford@sea.samsung.com
PANASONIC
(DRIVE THRU HEADSETS)
2 RIVERVIEW PLAZA, 6TH FLOOR NEWARK, NJ
07102
THERESA MURPHY 201‐492‐0925
theresa.murphy@us.panasonic.com
CASABLANCA DESIGN GROUP (DECOR)
811 PICKENS INDUSTRIAL DRIVE MARIETTA,
GA 30026
JOHN HARRISON 770‐423‐9575
John.Harrison@cdg.com
PINE HALL BRICK CO.
(THIN BRICK & FACE BRICK) 2701 SHOREFAIR
DRIVE, NW WINSTON‐SALEM, NC 27105
THERESA BEANE: (800) 334‐8689
TBEANE@PINEHALLBRICK.COM
EVOLUTION BRICK
(THINK BRICK, PANELIZED THIN BRICK &
FACE BRICK) 126 OLD HIGHWAY 60 EAST
HARDINSBURG, KY 40143 GABE POWERS:
(502) 558‐4612 gabe@evolutionbrick.com FOR FINISH MATERIALS, AND CONTACTS, REFER TO FINISH SCHEDULES
RINNAI
(INSTANT WATER HEATERS)
RINNAI NATIONAL ACCOUNT PRICING
THROUGH HAINES, JONES, & CADBURY
bk@hjcinc.com OR 800‐459‐7099
EVERPURE, INC (WATER FILTERS)
1040 MUIRFIELD DRIVE HANOVER PARK, IL.
60133 SEAN TEAL 630‐306‐0296
sean.teal@pentair.com
SICOM (XENIAL)
(POS, IDMB&ODMB HARDWARE/SOFTWARE,
SPEED OF SERVICE TIMER, KITCHEN
MINDER ‐CHEF)
4434 MEADOW DRIVE
DOYLESTOWN, PA, 18901
bksales@sicom.com
MICHAEL SCHWARTZ 215‐489‐2500 EXT 2249
michael.schwartz@xenial.com
STRATACACHE
(CONTROLLERS FOR INTERIOR MENU BOARDS
AND OUTDOOR DIGITAL MENU BOARDS)
40 North Main Street Dayton Ohio 45423
KEVIN FENTON (678)427‐3139
kfenton@stratacache.com
BMC USA LLC
(INTERIOR & EXTERIOR DÉCOR)
2655 SOUTH LE JEUNE ROAD, SUITE 905
CORAL GABLES, FL 33134
EMILIO MARTINEZ FERNÁNDEZ
emiliomartinez@bmcec.com
DIVISION 4 ‐ MASONRY DIVISION 9 ‐ FINISHES DIVISION 15 ‐ MECHANICAL EQUIPMENT, PLAYGROUNDS AND DÉCOR
UPDATE: 5‐20‐2022
This list is intended to assist the contractor in sourcing building materials and products. In many cases, approved Burger King materials and products may be purchased directly from these sources at a national accounts price. For a complete listing of approved manufacturers, see plans and specifications, and visit RSI's eRedbook.
DIRECTORY OF MANUFACTURERS AND SUPPLIERS
EXISTING STOREFRONT DOOR
AND WINDOWS TO REMAIN
EXISTING ALUMINUM
WINDOW TO REMAIN
EXISTING SIGNAGE TO
BE REMOVED
EXISTING BRICK TO BE
REMOVED ABOVE SILL HEIGHT
EXISTING EIFS TO REMAIN
EXISTING OVERHANG TO BE
REMOVED
EXISTING DRIVE THROUGH
OVERHANGS TO BE REMOVED
INCLUDING ROOF, WALLS,
SRUCTURE
EXISTING ROOF TO REMAIN
EXISTING MANSARD ROOF TO
BE REMOVED. STANDING
SEAM, ROOF STRUCTURE,
SOFFIT.
EXISTING GREEN HOUSE
STRUCTURE, GLAZING, BRICK,
AND SLAB TO BE REMOVED
EXISTING SIGNAGE
TO BE REMOVED
EXISTING BRICK TO
REMAIN
EXISTING WINDOWS
TO BE REMOVED
EXISTING METAL PARAPET
CAP TO REMAIN. CLEAN AND
REPAIR AS NEEDED
EXISTING ROOF TO REMAIN
EXISTING EIFS TO BE REMOVED
(GC TO VERIFY EIFS/ STUCCO
CONSTRUCTION)
EXISTING RED LED LIGHT
BAND TO REMAIN
EXISTING METAL PARAPET
CAP TO REMAIN
EXISTING BRICK TO REMAIN
BELOW SILL HEIGHT
EXISTING EIFS TO BE
REMOVED
NEW PARAPET
WALLS TO BE
CONSTRUCTED
NEW PARAPET
WALLS TO BE
CONSTRUCTED
NEW PARAPET
WALLS TO BE
CONSTRUCTED
NEW BRICK WATER
TABLE ON EXISTING
BRICK WALL
NEW EIFS WALL FINISH
NEW PAINT FINISH ON
EXISTING EIFS
EXISTING METAL
PARAPET CAP TO
REMAIN
NEW METAL
CANOPY WITH LED
SOFFIT LIGHTING
NEW METAL
CANOPY WITH LED
SOFFIT LIGHTING
NEW ALUMINUM
WINDOWS
NEW ALUMINUM
WINDOWS
NEW STOREFRONT
SIDE ENTRY DOOR
NEW CONCRETE
SLAB AT ENTRY
EXISTING WINDOW
TO REMAIN
EXISTING METAL
PARAPET CAP
NEW METAL PARAPET
CAP
NEW METAL
PARAPET CAP
NEW ROOF TO
MATCH EXISTING
NEW BK SIGNAGE
NEW NICHIHA
WALL SYSTEM
NEW THIN BRICK
VENEER
NEW BRICK VENEER WITH
BRICK WATER TABLE
NEW EIFS WALL
FINISH
NEW BK SIGNAGE
EXISTING EIFS TO BE
CLEANED AND
REPAIRED AND
PREPARED FOR PAINT
A T
T S
X
ETE
FO
S A
14 3 0 5
R E
G
IS
TERED ARCH
IT
E
C T
D A
V
ID
G. DUM
A
N
SCALE:
AAFES Project Number:
DATE:
SHEET:
PROJECT NUMBER
DRAWING TITLE:
Design. Spaces. People.
825 W. Vickery Blvd. #100 Fort Worth, Texas 76104
ph. (817) 738-8095
fx. (817) 738-9524 www.qarch.com
DRAWN BY:
CHECKED BY:
PROJECT:
EXCHANGE
EXCHANGE
CONSTRUCTION TYPE:
STORE TYPE:
IMAGE UPGRADE:
4792-22-004
JD
DL
RENOVATION
RESTAURANT
35% SUBMITTAL JD05/19/23
95% SUBMITTAL TM08/25/23
SOLICITATION ISSUE JD01/05/24
DATE REVISION NO & DESCRIPTION BY
/5
/2
:3
:2
A M
A-100
3D MODEL VIEWS
01/05/24
23074
SOLICITATION ISSUE
ARMY & AIR FORCE EXCHANGE SERVICE
BURGER KING
ELMENDORF AFB, AK
SCALE:A-100
1 DEMOLITION
SCALE:A-100
2 NEW
4 5
9 7
7 7
7 7
60' - 0"
MATERIAL AND EQUIPMENT
STORAGE AREA FOR
DURING CONSTRUCTION/
DEMOLITION
A T
T S
X
ETE
FO
S A
14 3 0 5
R E
G
IS
TERED ARCH
IT
E
C T
D A
V
ID
G. DUM
A
N
SCALE:
AAFES Project Number:
DATE:
SHEET:
PROJECT NUMBER
DRAWING TITLE:
Design. Spaces. People.
825 W. Vickery Blvd. #100 Fort Worth, Texas 76104
ph. (817) 738-8095
fx. (817) 738-9524 www.qarch.com
DRAWN BY:
CHECKED BY:
PROJECT:
EXCHANGE
EXCHANGE
CONSTRUCTION TYPE:
STORE TYPE:
IMAGE UPGRADE:
4792-22-004
JD
DL
RENOVATION
RESTAURANT
35% SUBMITTAL JD05/19/23
95% SUBMITTAL TM08/25/23
SOLICITATION ISSUE JD01/05/24
DATE REVISION NO & DESCRIPTION BY
1" = 20'-0"
/5
/2
:3
:5
A M
AD-103
DEMOLITION SITE PLAN
01/05/24
23074
SOLICITATION ISSUE
ARMY & AIR FORCE EXCHANGE SERVICE
BURGER KING
ELMENDORF AFB, AK
SCALE: 1" = 20'-0"AD-103
1 DEMOLITION SITE PLAN
1 EXISTING MONUMENT SIGN TO REMAIN. MAINTAIN POWER AND
CONDUIT. REPLACE EXISTING BK SIGN FACE.
2 CLEAN AND PREPARE DIRECTIONAL SIGNAGE FRAMES FOR
NEW PAINT FINISH - METAL TO BE PAINTED BLACK. NEW SIGN
FACE - REFER TO2/AS103
3 EXISTING BK GARDEN GRILL HEIGHT CLEARANCE BAR TO BE
REMOVED. FOUNDATION TO REMAIN.
4 EXISTING DIGITAL MENU BOARD TO REMAIN. CLEAN TO LIKE
NEW CONDITION.
5 EXISTING DIGITAL PREVIEW BOARD TO REMAIN. CLEAN TO LIKE
NEW CONDITION.
6 EXISTING OCU AND CANOPY TO BE REMOVED. EXISTING
FOUNDATION, POWER AND DATA TO REMAIN.
7 EXISTING LANDSCAPE TO REMAIN.
8 EXISTING DUMPSTER ENCLOSURE DOORS TO BE REMOVED
FOR REPAIR.
9 EXISTING CONCRETE CURB TO REMAIN.
10 EXISTING PAVING TO REMAIN.
11 EXISTING GREEN HOUSE CONCRETE SLAB TO BE REMOVED.
12 EXISTING CONCRETE FLATWORK TO REMAIN.
13 EXISTING PAVING TO REMAIN.
FLOOR PLAN NOTES
KEY NOTES DESIGNATED BY: X
1 1
60' - 0"
MATERIAL AND EQUIPMENT
STORAGE AREA FOR
DURING CONSTRUCTION &
DEMOLITION
PHASE 1
PHASE 2
PHASE 2
SCALE: 1" = 20'-0"AS-101
1 SITE PLAN
A T
T S
X
ETE
FO
S A
14 3 0 5
R E
G
IS
TERED ARCH
IT
E
C T
D A
V
ID
G. DUM
A
N
SCALE:
AAFES Project Number:
DATE:
SHEET:
PROJECT NUMBER
DRAWING TITLE:
Design. Spaces. People.
825 W. Vickery Blvd. #100 Fort Worth, Texas 76104
ph. (817) 738-8095
fx. (817) 738-9524 www.qarch.com
DRAWN BY:
CHECKED BY:
PROJECT:
EXCHANGE
EXCHANGE
CONSTRUCTION TYPE:
STORE TYPE:
IMAGE UPGRADE:
4792-22-004
JD
DL
RENOVATION
RESTAURANT
35% SUBMITTAL JD05/19/23
95% SUBMITTAL TM08/25/23
SOLICITATION ISSUE JD01/05/24
DATE REVISION NO & DESCRIPTION BY
As indicated
/5
/2
:3
:0
A M
AS-101
SITE PLAN
01/05/24
23074
SOLICITATION ISSUE
ARMY & AIR FORCE EXCHANGE SERVICE
BURGER KING
ELMENDORF AFB, AK
11 NEW OCU CANOPY TO REPLACE EXISTING BURGER KING
DRIVE-THRU CANOPY. USE EXISTING FOUNDATION, POWER,
AND DATA IF POSSIBLE.
12 REPAIR STRUCTURAL CRACKS IN DUMPSTER ENCLOSURE,
CLEAN, AND PREPARE DUMPSTER ENCLOSURE FOR NEW
PAINT FINISH. PAINT TO MATCH BUILDING STUCCO
FINISH.REFER TO A202.
13 CLEAN AND PREPARE DIRECTIONAL SIGNAGE FRAMES FOR
NEW PAINT FINISH. CABINETS/POLES TO BE FINISHED TO
MATCH PPG EXT "BLACK" PAINT-90-353. NEW SIGN FACE.
KEEP EXISTING FOUNDATION. REFER TO 2/AS103.
14 EXISTING MONUMENT SIGN TO REMAIN. MAINTAIN POWER
AND CONDUIT. REPLACE BK SIGN FACE. PAINT BRICK BASE
EP/2G.
15 TRASH ENCLOSURE GATES TO BE REPAIRED TO LIKE NEW
CONDITION AND PAINTED EP-4.
16 NEW SIDE ENTRY CONCRETE SLAB. EPOXY DOWEL INTO
BUILDING FOUNDATION.
17 DIRECTIONAL ARROWS TO BE REPAINTED. REFER TO
1/AS102
1 EXISTING LANDSCAPE TO REMAIN. PATCH AND REPAIR ALL
DAMAGED LANDSCAPE CAUSED DURING IMAGE UPGRADE.
2 NEW SOIL AND SOD TO REPLACE GREEN HOUSE AREA.
PATCH AND REPAIR ALL DAMAGED LANDSCAPE CAUSED
DURING IMAGE UPGRADE.
3 RESEAL AND RESTRIPE EXISTING PARKING LOT.
4 EXISTING DRIVE-THRU PAVING TO REMAIN. RESEAL AND
STRIPE AS REQUIRED.
5 EXISTING CONCRETE FLATWORK TO REMAIN.
6 EXISTING CONCRETE CURB TO REMAIN.
7 EXISITING BOLLARDS TO BE PAINTED BLACK.
8 EXISTING DIGITAL MENU BOARD TO REMAIN.
9 NEW BK GARDEN GRILL HEIGHT CLEARANCE BAR. REUSE
EXISTING FOUNDATION.
10 EXISTING DIGITAL PREVIEW BOARD TO REMAIN. CLEAN TO
LIKE NEW CONDITION.
FLOOR PLAN NOTES
KEY NOTES DESIGNATED BY: X
PHASING PLAN NOTES
SCALE: 1" = 10'-0"AS-101
2 PHASING PLAN
PHASING 1 (KITCHEN & DRIVE THROUGH TO REMAIN
OPERATIONAL)
1. DEMOLITION & CONSTRUCTION OF FINISHES IN THE
DINING AREA, VESTIBULE, ONE (1) RESTROOM, DRINK
STATION, AND SERVICE COUNTER.
2. ALL EXTERIOR MODIFICATIONS EXCEPT DRIVE
THROUGH SIDE.
3. ONE (1) RESTROOM TO REMAIN OPEN.
PHASING 2
1. DRIVE THROUGH AND ALL SITE ITEMS.
2. DRIVE THROUGH SIDE BUILDING MODIFICATIONS.
3. KITCHEN EQUIPMENT, FITTING, FURNITURE, CEILING
ETC. REMOVAL AND STORAGE TO REPLACE TILE GROUT
AS PER PLAN.
4. KITCHEN SUPPORT AREA TILE:
A. CLEAN TILE TO REMOVE ALL GREASE, STAINS, ETC.
PREP FOR REPAIR AND NEW GROUT.
B. REPLACE DAMAGED QUARRY TILE WITH NEW. BID
25% TILE REPLACEMENT AND 25% GROUT
REPLACEMENT.
C. REMOVE DAMAGED TILE GROUT AND REPLACE WITH
NEW EPOXY GROUT TO MATCH EXISTING OR MAPEI #
47 CHARCOAL.
D. REINSTALL EQUIPMENT, FITTING, AND FURNITURE.
5. DEMOLITION AND RECONSTRUCTION OF FINISHES IN
REMAINING RESTROOM.
1. GENERAL CONTRACTOR TO USE EXISTING MONUMENT SIGN CABINET AND REPLACE
MONUMENT SIGN FACES ONLY.
2. GENERAL CONTRACTOR TO REPLACE SITE DIRECTIONAL SIGN TOPS ONLY AND USE
EXISTING FOUNDATIONS.
3. GENERAL CONTRACTOR TO USE EXISTING FOUNDATION FOR DRIVE THRU CANOPY WITH
OCU, DRIVE THRU CLEARANCE SIGN BAR AND PREVIEW BOARD.
4. GENERAL CONTRACTOR TO SUPPLY AND INSTALL ALL SITE SIGNAGE.
SITE NOTES
SIDE ELEVATION FRONT ELEVATION
CLEARANCE 9'-0"
2' - 0"
24"
6" CURB
FINISH GRADE
D/T LANE
ALUMINUM PANEL W/
REFLECTIVE WHITE
VINYL BACKGROUND
AND 2.5" BLACK VINYL
LETTERING
EXTEND POLE 2'-0" INTO PIER
OR PROVIDE ANCHOR RODS
FOR BASEPLATE.
2' ROUND PIER W/ 4 - #5 VERT
AND #3 SQUARE TIES AT 18" OC.
AND 4" O.C. AT ANCHOR RODS
1. 120 VOLT 20 AMP ELECTRICAL SUPPLY TO SIGN
2. GC TO PROVIDE HDMI AND DATA CABLING - COORDINATE WITH VENDOR.
3. VERIFY LOWEST POINT IN D/T LANE BEFORE ORDERING SIGN
SINCE 1954
FLAME
GRILLING
6" CURB
FINISH GRADE
D/T LANE
SILVER
WOODGRAIN VINYL
GRAPHICS FRAME
(SILVER)
WHITE VINYL LETTERS
19"X17" SNAP LOCK
6' - 0"
/2
RECESSED LIGHT FIXTURE
TOP UNIT IS DESIGNED TO SWING
AWAY IF HIT BY A VEHICLE.
MUST ROTATE.
TOP VIEW
7' - 0"
1. GC TO PROVIDE HDMI AND DATA CABLING - COORDINATE WITH VENDOR
2. COORDINATE EXCAVATION OF SIGN FOUNDATIONS WITH SIGN SUPPLIER.
3. PROVIDE POWER TO ALL SIGN LOCATIONS AS REQUIRED.
4. MAKE FINAL ELECTRICAL CONNECTIONS TO EACH SIGN.
5. COMPLETE SIGN INSTALLATION.
GENERAL CONTRACTOR RESPONSIBILITIES:
THE EASIEST GAME OF LIMBO EVER X'-Y"
FRONT ELEVATION RIGHT SIDE ELEVATION
14"X14" STEEL BASE PLATE -
G.C. TO COORDINATE
ANCHOR BOLT PLACEMENT
16" ROUND PIER W/4 - #5 VERT
AND #3 SQUARE TIES AT 18" OC.
AND 4" O.C. AT ANCHOR RODS
5/8" x 30" ANCHOR BOLTS
FINISH GRADE
D/T LANE
6" CURB
FINISH GRADE
RED PAINT
2"X6" ALUMINUM
RECTANGULAR TUBE
VINYL (FRONT)
O R
L O
W E
S T
P O
IN
T
I N
D R
IV
E
T H
R U
V E
R
IF
Y C
L E
A R
A N
C E
H E
IG
H
T B
E F
O R
E O
R D
E R
IN
G
S
IG
N
8' - 0"
1' - 4"
1' - 0"
WOOD GRAIN
VINYL
FINISH GRADE
1' - 2"
TOP VIEW
"SWING AWAY BAR"
GENERAL CONTRACTOR RESPONSIBILITIES:
1. COORDINATE EXCAVATION OF SIGN FOUNDATIONS WITH SIGN SUPPLIER.
2. PROVIDE POWER TO ALL SIGN LOCATIONS AS REQUIRED.
3. MAKE FINAL ELECTRICAL CONNECTIONS TO EACH SIGN.
4. COMPLETE SIGN INSTALLATION.
TYP.
1'-0"
T Y
P
/4
/4
TYP.
2'-0"
3'-9"
R 4' - 0"
4'-9"
R 2' - 0"
GENERAL CONTRACTOR RESPONSIBILITIES:
1. PROVIDE ALL INFORMATION INCLUDING DRAWINGS AND
LOCATIONS REQUIRED FOR REVIEW AND APPROVAL.
3. PAINT ARROWS AT DESIGNATED LOCATIONS.
2. REMOVE EXISTING PAINTED ARROWS FROM PAVEMENT.
WHITE TRAFFIC
PAINT SYMBOL
BLUE TRAFFIC PAINT
BACKGROUND.
1) ALL STROKES TO BE 2" WIDE
2) PROVIDE TWO (2) COATS OF TRAFFIC
PAINT.
3) LOCATE SYMBOL AT CENTER OF STALL
WHERE SHOWN ON SITE PLAN.
3'-0"
A T
T S
X
ETE
FO
S A
14 3 0 5
R E
G
IS
TERED ARCH
IT
E
C T
D A
V
ID
G. DUM
A
N
SCALE:
AAFES Project Number:
DATE:
SHEET:
PROJECT NUMBER
DRAWING TITLE:
Design. Spaces. People.
825 W. Vickery Blvd. #100 Fort Worth, Texas 76104
ph. (817) 738-8095
fx. (817) 738-9524 www.qarch.com
DRAWN BY:
CHECKED BY:
PROJECT:
EXCHANGE
EXCHANGE
CONSTRUCTION TYPE:
STORE TYPE:
IMAGE UPGRADE:
4792-22-004
JD
DL
RENOVATION
RESTAURANT
35% SUBMITTAL JD05/19/23
95% SUBMITTAL TM08/25/23
SOLICITATION ISSUE JD01/05/24
DATE REVISION NO & DESCRIPTION BY
As indicated
/5
/2
:3
:0
A M
AS-102
SITE DETAILS
01/05/24
23074
SOLICITATION ISSUE
ARMY & AIR FORCE EXCHANGE SERVICE
BURGER KING
ELMENDORF AFB, AK
SCALE: 1/4" = 1'-0"AS-102
1 ORDER CONFIRMATION UNIT
SCALE: 1/4" = 1'-0"AS-102
4 CLEARANCE SIGN DETAILS
SCALE: 1/2" = 1'-0"AS-102
3 PAINTED ARROW DETAILS
SCALE: 1/2" = 1'-0"AS-102
2 HANDICAP SYMBOL DETAIL
1 1
E
E
A
A
H
H
B
B
D F
F
G
G
AD-201
AD-2014
AD-201
AD-201 3
VEST.
MEN'S
WOMEN'S
DINING
KITCHEN
FREEZER
COOLER
OFFICE
CREW
STORAGE
2 2
C
C
11 12
13 14
GREEN
HOUSE
2 2
MECHANICAL
29 29 29
28 27
A-101
BASE BID - EXISTING RESTROOM FINISHES, FIXTURES, ACCESSORIES TO REMAIN. REF. SPECS.
NO WORK ZONE
PATCH / CLEAN AND REPAIR AREA
AFFECTED UNLESS NOTED OTHERWISE
EXISTING FRAMED PARTITION TO
REMAIN
WALL / MISC TO BE REMOVED
SCALE: N.T.S.AD-101
1 DEMOLITION FLOOR PLAN
A T
T S
X
ETE
FO
S A
14 3 0 5
R E
G
IS
TERED ARCH
IT
E
C T
D A
V
ID
G. DUM
A
N
SCALE:
AAFES Project Number:
DATE:
SHEET:
PROJECT NUMBER
DRAWING TITLE:
Design. Spaces. People.
825 W. Vickery Blvd. #100 Fort Worth, Texas 76104
ph. (817) 738-8095
fx. (817) 738-9524 www.qarch.com
DRAWN BY:
CHECKED BY:
PROJECT:
EXCHANGE
EXCHANGE
CONSTRUCTION TYPE:
STORE TYPE:
IMAGE UPGRADE:
4792-22-004
JD
DL
RENOVATION
RESTAURANT
35% SUBMITTAL JD05/19/23
95% SUBMITTAL TM08/25/23
SOLICITATION ISSUE JD01/05/24
DATE REVISION NO & DESCRIPTION BY
As indicated
/5
/2
:3
:4
A M
AD-101
DEMOLITION FLOOR PLAN
01/05/24
23074
SOLICITATION ISSUE
ARMY & AIR FORCE EXCHANGE SERVICE
BURGER KING
ELMENDORF AFB, AK
15 ALL SEATING TO BE REMOVED.
16 DRIVE- THRU WINDOWS TO BE REMOVED.
17 COUNTER CONSTRUCTION TO REMAIN. REMOVE COUNTERTOP
AND PREPARE REMAINING STRUCTURE FOR NEW
COUNTERTOP.
18 CLEAN AND PREPARE WALLS FOR NEW FINISH. REFER TO SCI
DRAWINGS.
19 EXISTING KITCHEN EQUIPMENT TO REMAIN. U.N.O.
20 EXISTING DOOR TO REMAIN. PAINT TO MATCH SURROUNDING
ELEVATION. EP/4G.
21 EXISTING SODA DISPENSERS AND ICE MAKERS TO REMOVED
AND REINSTALLED.
22 EXISTING DRINK STATION DOORS TO BE RELAMINATED.
23 GC TO REMOVE AND STORE MENU BOARDS. OWNER TO
RECONNECT DATA.
24 EXISTING LADDER TO REMAIN.
25 REF. AD201 FOR EXTERIOR MATERIAL DEMOLITION.
26 STOREFRONT DOOR AND WINDOW TO BE REMOVED.
27 STEAM BASE BOARD HEAT TO REMAIN.
28 EXISTING STEAM BASE BOARD HEAT TO BE REMOVED.
29 EXISTING ALUMINUM WINDOWS TO BE REMOVED.
30 REMOVE AND REPLACE DRYWALL IN DRINK STATION AREA WITH
GREEN BOARD.
1 INTERIOR WALL TO BE PREPARED TO BECOME EXTERIOR WALL.
REF. STRUCT. REF. WALL SECTIONS.
2 EXISTING ALUMINUM WINDOWS TO REMAIN.
3 EXISTING STOREFRONT DOORS AND WINDOWS TO REMAIN.
REMOVE EXISTING SPATULA DOOR HANDLES.
4 GREEN HOUSE STRUCTURE TO BE REMOVED.
5 GREEN HOUSE SLAB TO BE REMOVED. REF. STRUCT.
7 ALL FINISHES IN RESTROOM TO BE REMOVED. FLOOR TILE,
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .