FY26 Trailer Sources Sought.pdf

PDF 277 KB Posted

Attached to
FY26 Trailers Sources Sought
Solicitation number
FA468626TRAIL
Issued by

About this file

This is a Sources Sought notice for the procurement of three trailer-mounted systems for the Water Fuels and Systems MTX shop. The government is searching for two stall trailer-mounted restroom systems, one gravity tilt trailer system, and one bottle fill trailer system.

The two stall trailer-mounted restroom systems must have overall dimensions of 9.3 feet long by 6.7 feet wide by 8.6 feet high with a 4-foot towbar. Each unit requires a single axle with two tires, mechanical braking system with hand brake, heavy-duty rust-resistant frame, secure safety coupling for tractor towing, four stabilizing corner jacks with extendable legs, high-flow heavy-duty water pump with sink and integrated tanks, LED lighting with power outlets and circuit breaker panel, and a maximum load capacity of 2,000 kilograms (4,500 pounds). The gravity tilt trailer must be a 7x25 (17+8) bumper pull configuration with 20,000-pound capacity, tandem 9,000-pound direct lube axles with electric brakes on both axles, 1/8-inch diamond plate flooring, 102-inch width with drive-over fenders, 17-foot tilt deck with stationary front platform, one spare tire, 17-inch ST235/75R17.5 18-ply radial tires, fully primed and painted finish, and lifetime LED stop/turn/clearance lighting. The bottle fill trailer must feature a galvanized DOT-approved trailer with a 500-gallon NSF/FDA compliant tank, 100-gallon rinsing/flushing tank, stainless steel dispensing faucets, 110-volt water pump, UV disinfection system with reverse cleaning pump, storage bin at the tongue, chiller system, and generator to power the cooling water chiller. All tank, piping, and pump components must be NSF/FDA compliant.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SOURCES SOUGHT

Search for Two (2) Stall Trailer Mounted Restroom system, One (1) Gravity Tilt Trailer system, One (1) Bottle Fill Trailer system.

1.0 SCOPE

A. Project Scope.

(1) Searching for Two (2) Stall Trailer Mounted Restroom system for Water Fuels and Systems MTX shop.

Trailer Mounted Restroom specifications: (May vary based on manufacturer)

• Overall Size: 9.3 ft (L) × 6.7 ft (W) × 8.6 ft (H)

• Towbar Length: 4 ft (1,200 mm)

• Axle & Brake System: Single axle with two tires, equipped with a mechanical braking system and hand brake

• Suspension: Heavy-duty frame with rust-resistant treatment

• Towbar: Equipped with a secure safety coupling for tractor towing

• Stabilizing Jacks: 4 (one on each corner, with extendable legs)

• Water System: High-flow heavy-duty water pump, sink, and integrated tanks

• Electrical System: LED lighting, cables, power outlets, switches, and circuit breaker panel

• Maximum Load Capacity: 2,000 kg(4500lbs.)

(2) Searching for One (1) Gravity Tilt Trailer system for Water Fuels and Systems MTX shop.

Gravity tilt trailer Specifications: (May vary based on manufacturer)

• 7x25 (17+8), 20k Bumper Pull, Gravity tilt Trailer

• Tandem 9k lbs Direct Lube 8 lug (Electric brakes on both axles

• 1/8” Diamond Plate flooring

• 102” Wide with Drive over Fenders

• 17’ tilt deck with stationary front platform

• 1 Spare Tire

• 17.” ST235/75R17.5 18ply radial LRJ Tires

• Fully primed and painted with high grade acrylic enamel

• All flush mount or recessed lifetime LED stop / turn / clearance lighting

(3) Searching for One (1) Bottle fill trailer system for Water Fuels and Systems MTX shop.

Bottle fill trailer Specifications: (May vary based on manufacturer)

• Galvanized DOT approved Trailer

• 500 gallon NSF / FDA Compliant tank

• 100 Gallon rinsing flushing tank

• Stainless Steel dispensing faucets for water bottles

• 110V Water pump to pressurize delivery lines

• UV Disinfection system with reverse cleaning pump

• Storage Bin Mounted at tongue of trailer

• Chiller System

• Generator to power cooling water chiller.

• The tank and piping and pump is NSF / FDA Compliant.

STATEMENT OF NEED
1.0 SCOPE

File details come from the government source that posted it. Updated .