FY24 HJEF Electrical Demo - Drawing.pdf

PDF 2 MB Posted

Attached to
HJA Electrical Demo on Cabin
Solicitation number
1240BJ24Q0030
Issued by

About this file

This document is a drawing and outline of the electrical configuration in the maintenance residence cabin at the HJ Andrews Experimental Forest in Blue River, Oregon. The key details are:

The drawing shows the current electrical setup in the cabin, including the location of two electrical panels, wall heaters, outlets, and other electrical components. It indicates that the electrical wiring has been degraded by rodent damage, creating fire hazards and potential for electrocution. The related federal contract opportunity is for a contractor to remove the two electrical panels and current electrical wiring within the walls, ceiling, and floors of the maintenance residence, in preparation for a new electrical panel and rewiring of the structure. The contractor will be required to salvage wood wainscoting and dispose of removed building materials and electrical wires. The work must be performed in accordance with the statement of work and all federal, state, and local laws and regulations. The agency involved is the Department of Agriculture Forest Service.

View the file

Other files

File Type Posted
1240BJ24Q0030 HJEF Electrical Demo.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PACIFIC NORTHWEST RESEARCH STATION

HJ Andrews Experimental Forest

Electrical Demo on Cabin at

HJ Andrews Experimental Forest USFS Road 15-130-132

Blue River, Oregon 97413

Date: 05/15/2024

______ Date: 05/22/2024

Prepared By: Gary Villanueva

Reviewed By:

Station Engineer

Approved By: _________________________ Date: .

Portland:

Approximately 156 Miles to HJ Andrews Experimental Forest Approximately 2 Hr. 45 Min Travel Time

Eugene:

Approximately 50 Miles to HJ Andrews Experimental Forest Approximately 60 Min Travel Time

Maintenance Shop Building

Maintenance Residence – Project Site (Care Taker’s Cabin)

Administrative Building

Administrative Building

Project Site Maintenance Residence

(Care Taker’s Cabin)

Maintenance Shop Building

Wall Heater Wall Heater

Wall Heater

Wall Heater

Electric Water Heater

Electrical Panel 1

Electrical Panel 2

HJ Andrews Experimental Forest Maintenance Residence – Electrical Configuration (Approximate)

Main Electrical Feed Main Electrical Feed

(125 Amps) From Maintenance Shop

Electric Stove

2 - Electrical Sub-panels 4 – Wall Heaters 1 - Stove Outlet 1 - Dryer Outlet 1 - Water Heater Connection 11 - Electrical Light Switches 35 - Electrical Outlets

12’x24’

Foyer

8’x10’ Room 2

10’x12’

Kitchen

Roof Peak

Roof Peak12’x19’

Open Room

11’x11’

Room 3

10’x10’

Room 1

Room 4

8’x 9’

Restroom 1 Restroom 2

Electric Dryer

Dishwasher

Electrical Panel 2

Electrical Panel 1

Electrical Panel 1

Electrical

Existing Electrical Panels 1 & 2

Maintenance Shop Electrical Panel Power Feed to Maintenance Residence

Electrical

Electrical Panel 1

Electrical Panel 1

Maintenance Residence - Front & South Side

Main Electrical Feed

Maintenance Residence - Front & North Side

Maintenance Residence – East Side

Non-NEC Electrical Wiring Examples

Slide Number 1
Slide Number 2
Slide Number 3
Slide Number 4
Slide Number 5
Slide Number 6
Slide Number 7
Slide Number 8
Slide Number 9
Slide Number 10
Slide Number 11
Slide Number 12
2024-05-22T08:28:47-0700
KYLE HUDDLESTON
2024-05-22T07:27:52-0700
ROBERT AVILA

File details come from the government source that posted it. Updated .