FY23_1__Appendix_A_-_Const_Specs_-_Production_Offices_FINAL_2022-10-19_(1).docx

DOCX document 16 MB Posted

Attached to
ARMED FORCES CAREER CENTER
Solicitation number
W912QR-IRONMOUNTAINMIFY25
Issued by

About this file

This file appears to be an appendix containing construction specifications (Appendix A) related to a lease solicitation for Armed Forces Career Center office space. The solicitation seeks approximately 2,410 square feet of commercial retail office space within a mile radius of 1170 & 1074 South Stephenson Avenue in Iron Mountain, MI (zip code 49801). The Department of the Army Corps of Engineers Engineering District Louisville is managing the procurement, with proposals due by 5:30 PM on December 22, 2024.

While this is labeled as a construction specifications document, without access to the actual content of the appendix, I cannot provide details about specific construction requirements or standards contained within it. The related opportunity indicates this is part of a broader lease solicitation package, with Ed Andino serving as the point of contact for additional information.

View the file

Other files

File Type Posted
Nationwide Lease Master 2021 for New Office or Relocation .docx DOCX document
Attachment 2_General Clauses.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

APPENDIX “A”

Military Recruiting Facilities CONSTRUCTION SPECIFICATIONS for Production Offices

VERSION: FY 23.1

(Address) (Date)

GENERAL STANDARDS (GS)

A. General Guidance:

Each designated Military Service to be located at this recruiting facility will have their specific standards utilized along with the following General Standards (GS). Any significant departure from either the intent of these construction specifications or the approved Chief Architect floor plan will require prior approval of the Corps of Engineers (COE); P.O.C.:_________________, phone #:_________, email:_________. IMPORTANT: NOTHING IN THESE SPECIFICATIONS WILL PROHIBIT THE SUBSTITUTION, WITH PRIOR APPROVAL OF THE COE, OF AN EQUIVALENT PRODUCT, SERVICE OR FINISH (TO INCLUDE ALL PARTS, COMPONENTS, ETC. MEETING THE SPECIFIED REQUIREMENTS HEREIN). LESSOR / CONTRACTOR(S) TO PROVIDE WRITTEN CERTIFICATION OF EQUIVALENCY TO COE REPRESENTATIVE PRIOR TO APPROVAL / INSTALLATION.

IMPORTANT: For all supplied communication requirements and electronic security applications (K.1. & K.2. below), the Lessor (or their contractors) are PROHIBITED (2019 N.D.A.A. law) from providing to the Government any such equipment or services as a substantial or essential component, or critical technology as part of any system. These security / telecommunications products are PROHIBITED to be from any of the following source entities, any subsidiary or affiliate of such source entities: 1) The People’s Republic of China; 2) Huawei Technologies Company; 3) ZTE Corporation; 4) Hytera Communications Corporation, Hangzhou Hikvision Digital Technology Company; 5) or Dahua Technology Company. Lessor (or contractors) must certify the equipment is not from any of these sources and provide written confirmation to the COE Representative prior to installation. Upon acceptance of the premises, the Lessor or Contractor must re-certify in writing what equipment has been installed, and that all components comply with the 2019 N.D.A.A. requirements.

1. The Lessor will be responsible for permitting, constructing, operating, maintaining, and obtaining a Certificate of Occupancy for the leased premises in accordance with the lease / solicitation requirements. Any changes on the build out of the premises should be addressed directly to the COE representative. The recruiters for the subject office(s) are NOT authorized to change / modify anything related to the construction of the office.

The attached conceptual drawing / Chief Architect floor plan provided by the COE representative will be used for design, planning, and bid purposes.

a. Required Lessor deliverables for Architectural / Engineering (AE) drawings:

1. The Lessor is responsible for coordinating with the COE in the development of these plans.

2. Lessor’s AE drawings must be created and provided to COE representative prior to scheduling the pre-construction “kickoff” meeting.

3. IMPORTANT: Conceptual drawings / floor plans and/or AE drawings in draft or final form shall NOT be posted online or provided to third parties for security reasons.

4. COE representative to review and approve all Lessor provided AE drawings prior to starting construction activities or premises alterations. No construction shall start until the COE representative provides an official Notice to Proceed (NTP) for construction.

5. AE Drawing sets to include at a minimum (but not limited to) the following:

i. Architectural cover sheet, site, and parking plan with all details / abbreviations / symbols.

ii. Floor plan / AE drawing to provide dimensions and square foot allocations, wall, door, window, structural columns, key notes, etc.).

iii. Mechanical, Electrical and Plumbing (MEP) Engineering Drawings:

· Including low voltage communications / data / controls.

· Aiphone, CCTV, roller shade controls and security systems / items.

iv. Interior design drawings for walls, ceilings, and floor finish plan with schedules.

v. Interior / Exterior elevations with graphics and signage details / schedules, etc.

vi. Interior / Exterior door and window hardware schedules and finish details, etc.

vii. IMPORTANT: Once finalized and approved by local municipalities, FINAL AE drawings shall be provided to the Government in electronic formats as follows:

· PDF file(s) in 11” x 17” page format.

· Electronic DWG file(s).

· The electronic AE drawing file(s) shall serve as a basis to resolve any issues of variance which may arise.

2. Codes and Standards: The facility must comply with all Federal, State and local construction standards, building codes and all other applicable laws. Any variance from these guidelines must have prior approval by the authority having jurisdiction. Where conflicts between standards arise, the build-out of the recruiting office must comply with the most stringent requirements.

3. Only Energy Star labeled components and natural resource conserving / recyclable products shall be installed.

4. Number of Recruiters: For the purposes of determining the number of keys or access control system desk stations per Military Service, the following number (#) of recruiters for each Military Service is provided:

Army _______; Navy _______; Air Force _______; Marines _______;

Air Force Reserve _______; Air National Guard _______; Army National Guard ________.

B. Mechanical:

1. Plumbing / electrical / HVAC and mechanical service lines / facilities, if located within the leased premises, shall be enclosed within wall cavities. Exposed ducts, piping, cables / wiring, and/or conduit runs are not permitted in the offices or common areas of the leased premises. If there are Lessor / building mechanical rooms / space accessed from within the Government controlled premises, this enclosed space may NOT, under any circumstances, be considered part of the Government leased premises or co-used for any other purposes.

2. Heating, Ventilation and Air Conditioning (HVAC):

a. The HVAC system design shall conform to applicable temperature standards and operating practices. If existing, the present HVAC system shall be balanced to accommodate the floor plan / AE drawing and operational needs of each Military Service. If not otherwise stipulated, the HVAC equipment shall be capable of maintaining a minimum temperature of 70 degrees Fahrenheit during the heating season and a maximum of 76 degrees Fahrenheit during the cooling season regardless of outside temperature. Areas that may be affected by solar radiation (either excessive heat gain or loss) shall be accounted for by the Lessor within the design of the HVAC system.

b. The HVAC system, shall be designed and provide temperature controlled thermostats in each individual Military Service office. The contractor will coordinate with the COE on the determination of acceptable thermostat(s). A digital, 7-day programmable, code-protected thermostat shall be utilized. Thermostat’s to be mounted in each individual Military Service “open office” areas.

c. Ventilation to the leased premises shall be provided in the most energy efficient and cost-effective manner. It will meet or exceed all applicable building code standards and local ordinances.

d. Security Closets: The security closet [to be utilized with the Closed Circuit Television (CCTV) system – see paragraph K.2.n. for more details] shall have its own supply and return vents installed for adequate ventilation for appropriate air flow heat dispensation.

e. For energy efficiency requirements:

1. When required by the State (e.g. - California Title 24) – all 5 ton or greater HVAC units / systems to incorporate:

i. Air-to-Air exchanger / economizer (if not already present).

ii. A “residential” style HVAC system with zoning / dampers to heat or cool specific areas as needed. Avoiding ductless / split HVAC systems if possible.

iii. Smart thermostat in each individual Military Service’s office.

iv. Stand-alone HVAC system: **NO** connection to Government networks, internet, routers, or WiFi is allowed.

3. Indoor Air Quality: HVAC flush-out shall commence after construction ends and the Building has been completely cleaned. All interior finishes, such as millwork, doors, paint, carpet, and acoustic tiles must be installed, and major volatile organic compound (VOC) punch list items must be finished. Prior to occupancy, supply / return vents to be cleaned and free of construction debris / dust. Lessor shall install new filtration media and perform a building flush-out by supplying outdoor air to flush out VOC’s.

C. Plumbing:

1. Potable water shall be provided to the leased premises. The Lessor shall verify the existing water supply meets all potable water standards. If deficient, the Lessor will be responsible for providing an acceptable, alternate water supply. The water heating system shall produce and maintain a hot water temperature of 105 degrees for restrooms and the janitorial mop service sink. All water heater systems must be secured from public access and out of public view.

2. Restrooms: At a minimum, a unisex restroom will be provided. Recruiting offices with six (6) or more authorized recruiters shall require two (2) restrooms. Lessor will confirm number of restroom facilities required at this location as _________. Restrooms shall contain, at a minimum, the following plumbing fixtures and approximate square footage:

a. Unisex / Men's: 100 sq. ft., 1 commercial toilet, 1 urinal, 1 sink, stainless steel partitions / urinal screens as required.

b. Women's (if required): 64 sq. ft., 1 commercial toilet, 1 sink.

c. Restroom Fixtures & Accessories: See para. G.8.

d. If existing, restrooms to be updated with all appropriate paint, tile, fixtures, etc.

3. Drinking fountain-water cooler: The Lessor to install a stainless steel drinking fountain equal to Elkay EZ Series, EZS8WSSK, non-filtered electric water cooler, with an attached EZH20 bottle filling station. Location as shown on the floor plan / AE drawing.

4. Janitorial Closet: shall contain 1-floor mounted mop sink and service faucet with a hot and cold water supply.

D. Electrical:

1. Electrical Distribution: Each electrical circuit shall be 20 amp rated or greater as defined by the National Electrical Code (NEC). All outlets shall be Quadplex unless otherwise specified, spaced a maximum of 8-feet apart and shall be installed in offices, test rooms, conference rooms (where applicable), and foyers. Installation to be at industry standard height unless otherwise specified. Installation at desktop or countertop level (as required) will be as specifically referenced on the floor plan / AE drawings.

a. All electrical panels servicing the Government leased premises should be located within the leased premises. When located outside the leased premises inside or outside the building the panel(s) must be secured (locked).

b. Unless referenced differently within each Military Services’ section, electrical faceplate for all outlets shall be: standard white. For unique, Military Service specific electrical requirement(s), see applicable Military Service Attachment.

c. Security Closet & Communication (Commo) Boards for EACH Military Service: Two (2) quadplex outlets as shown on ENCLOSURE # 1a and 1b, (see paragraph E for more details) and commo board shall be installed on the same wall with isolated copper grounding plate connected to a green #6 ground wire which will then be attached either to the building ground or grounding rod in accordance with local standards. Note: An equivalent standard for isolated electrical ground installation is acceptable. See paragraph K.2.n. for more details.

d. Each individual Military Service’s storage room will have quadplex outlets spaced at 6-foot intervals.

e. Janitorial closet outlet mounted 42” above finished floor (AFF); will be located as shown on floor plan / AE drawing.

f. Conference / Multi-Purpose Rooms (if indicated on the approved floor plan / AE drawing): Install an adequate floorport to allow at a minimum: a duplex outlet, duplex CAT6 outlet, an HDMI female port, with HDMI cable run to the non-CCTV television (TV) / monitor mounting pole, and two (2) pull strings to the respective Commo Board.

g. Additional Specific Electrical Requirements:

1. Communications (paragraph E).

2. Restroom Fixtures (paragraph G.8.).

3. Single / dual roller shades (paragraph G.9.a.1).

4. Video entry access control systems (paragraph K.1).

5. Mounted TV / monitors (paragraph D.6).

6. CCTV / NVR systems (paragraph K.2).

2. Interior Lighting: UL listed light fixtures shall be capable of producing and maintaining a uniform lighting level of a minimum of 50 foot-candles of illumination at working surface height in all office spaces. All other non-working areas will have a minimum of 30 foot-candles of illumination at floor level.

a. LED: Lighting provided by the Lessor in all office, hallways, display areas and test rooms will be a minimum of 2 x 4 flat panel, 4300 lumens, 4000k temperature, energy efficient, LED light fixtures, with a minimal lifespan of 60,000 hours. In lavatories and smaller rooms requiring smaller scaled fixtures, similar 2x2 energy efficient, recessed LED fixtures will be provided. Note: If existing light fixtures differ from those specified, the Lessor will consult with the COE on their acceptability. If existing fixtures are used, LED lamps to be installed. Interior office spaces and test rooms to have wall mounted on-off switch with full range dimmers. All other areas to use standard commercial grade switches without dimmers.

b. LED: Shall be installed in mechanical rooms, security closets, janitorial closets and other working areas as needed.

c. Emergency Lighting: Shall be built into the LED ceiling light fixtures, with an emergency driver component in order to maintain illumination throughout the means of egress. Light fixtures with emergency drivers are to be hardwired to maintain an adequate charge on battery pack to provide at least 1-½ hours of power to light as per NFPA 101. Each fixture to have a “test light indicator” (LED Combo Test Switch – (LCTS)) installed next to the fixture. The LCTS light color is preferred to be green (indicating the light and battery backup is in good working order). LCTS cover shall be white to match ceiling tiles.

3. Exterior Lighting:

a. The Lessor will ensure building egress doors and designated government parking areas use energy efficient lighting with a minimum illumination of 3 foot-candles / square foot at ground level.

b. Front entrances: Where possible, install overhead recessed and/or flush lighting fixture located directly above facility front entrance (exterior) door(s).

c. Rear Exit, if applicable: If not already present, an exterior security light shall be installed by the Lessor. Light fixture to be LED, equivalent to 150 watts or greater, with ‘dusk-to-dawn’ light sensor with manual override.

4. Outlets, Switches and Cover Plates: Shall be standard, commercial grade. All switches shall be color coordinated with required faceplates. See specific Military Service Attachment for appropriate color information.

5. Entry Bell: The Lessor will install a hard-wired entry alert door chime to all front, and secondary exterior doors. NO WIRELESS and/or BATTERY OPERATED CHIMES ALLOWED. The system shall be installed to ensure the door chime is operated by the opening of the door and shall have a tone acceptable for an office environment and must be audible in all collocated Military Services’ offices. The COE will approve the proposed tone of the chime before installation. The main entry chime shall have a two-tone ping (e.g. - “ding-dong”) while the secondary exit door chimes shall have a single-tone ping (e.g. - “ding”). If site specific conditions require a non-electrical door chime, a fully mechanical system (no electrical wiring) is allowed, as long as each Military Service can hear them in their offices.

6. Mounted TVs / Monitors: Duplex outlet, CCTV HDMI cable, and communications outlet boxes (with CAT6) to be installed and concealed above ceiling tiles directly above TV / monitor mounting location as indicated on the approved floor plan / AE drawing. Mounting height to be 8’-6” AFF for top edge of TV / monitor. See paragraph K.2.i for more details regarding TV / monitor mounting pole requirements.

7. Roller Shades: Wiring to be contained in appropriate conduit in wall and ceiling interstitial / plenum space, and be arranged in a tight compact arrangement / appearance.

E. Communications:

1. Outlets, Switches and Cover Plates: See “Electrical Distribution” paragraph D.1.

2. Telephone Equipment: The telephone demarcation point provided by the Lessor must be secured from public access. If required, mitigation to secure the demarcation point shall be coordinated with the COE. The telephone system shall be capable of supplying the required phone service to each military office and be so installed as to provide easy activation by the Military Service’s phone service and their provider(s). The Lessor shall coordinate with the COE’s representative on the number of required phone lines for each Military Service.

3. Communications Board (known herein as the specific Military Service’s “communication” or “commo” board): Within each Military Services storage room, Lessor to wall mount a ¾” thick, 4’-0” W x 4’-0” H fire-retardant treated plywood backboard, at 4’-0” AFF. Commo Board to have fire-resistant paint finish to match adjacent walls. The commo board location must have 36” of front clearance to facilitate access and have 2 shelves (12” x 24”) and outlets mounted with locations for both as shown on ENCLOSURE # 1a and 1b. See paragraph D.1. for electrical requirements.

4. Telecommunications (See ENCLOSURE # 1a and 1b for a simplified diagram of telecommunications requirements):

a. Outlets / Wiring: Shall be installed within 2” horizontally of electrical outlets. These telecommunications and electrical outlets will be aligned so that the tops of both outlets measure to the same height AFF. These telecommunication outlet boxes shall be duplex; with 1” conduit terminating 12” above finished wall height. Note: The Lessor shall be responsible for any special telecommunication permitting requirements (e.g. - low voltage permits, etc.), which shall be a requirement to obtain a “Certificate of Occupancy”.

1. Each wall outlet (destination end) shall be equipped with two (2) female RJ45 sockets, each connected by a Straight-Through CAT 6 cable (T568B).

2. All wiring coming into the top of the communications board shall be collected and routed in an organized manner.

3. The source end of the Straight-Through CAT 6 cable shall have a minimum of three (3) feet of slack at the communications board to allow the cables to plug into Military Service(s) provided equipment. The ends of each Straight-Through CAT 6 cable at the communications board shall be equipped with a male RJ45 connector.

4. The RJ45 connector can then be connected to a modem, router, switch, adaptive security appliance, etc., which is installed by the Military Service’s telecom provider.

5. Each CAT 6 cable / wall outlet shall be labeled / tagged at the source (communications board) and destination (wall outlet) ends with the corresponding port number for easy identification.

6. All Communications outlets, faceplates, and data ports to be coordinated with electrical faceplate color requirements.

7. For unique, Military Service specific outlet requirement(s), see applicable Military Service Attachment.

8. For locations that have more than one Military Service sharing a communications board, each cable shall also be labeled for each Military Service as follows:

i. Air Force=“USAF”
ii. Air Force Reserve=“AFR”
iii. Army=“USA”
iv. Navy=“USN”
v. Marine Corps=“USMC”
vi. Air National Guard=“ANG”
vii. Army National Guard=“ARNG”

b. Conduit: The Lessor shall install conduit (minimum of 1” or greater for each office or building layout) capable of handling the telephone and high-speed internet access needs for ALL of the Military Service(s); requirements are as follows:

1. From the building’s communications demarcation point to the commo board for each Military Service within the leased premises (conduit sized to fit ALL Military Services, with two (2) pull strings per Military Service). If a junction box is necessary (due to local code) between the buildings communications demarcation point and the Military Service(s) commo board, conduit and two (2) pull strings are required between this junction box and 1) the building demarcation point; and 2) the Military Service(s) commo board.

2. From each of the telecommunication wall and floor (see paragraphs E.4 & D.1.) outlet boxes to the commo board, conduit to terminate 12” above finished wall height (1” minimum diameter in size for CAT6 cabling in paragraph 4.a above). See raceway requirements below. Note: This is separate from CCTV requirements, see K.2 for more details.

c. Raceways: Wiring not contained in conduit shall be raceway installed.

d. Military Services Responsibilities & Equipment: Military Services are responsible for all remaining telecommunications requirements via their service provider (e.g. – Verizon, AT&T, etc.) that are not reflected above. The following list (but not limited to) is what the Military Services telecom provider will install, etc.:

1. Any equipment / cabling / wiring / terminations required from the building demarcation point and/or junction box to the commo board, including any equipment required at the commo board to include (but not limited to) modems, routers, PBX’s, network switches, intermediate distribution frames, main distribution frames, distribution frames of any kind, patch panels, punch blocks, etc.

2. Any patch cables to connect all equipment.

3. All communications services (internet, Wi-Fi, cable TV if applicable (not part of the CCTV system), signal repeaters, etc.).

4. It is each Military Service’s / telecom providers responsibility to coordinate with the Lessor, and to install or contract for installation, all remaining required telephone, telecommunications, and internet equipment (including any not listed in Lessor’s responsibilities above).

5. This would include any additional low voltage communications permits as required.

F. Safety and Fire Equipment:

1. The Lessor shall be responsible for any required remediation of the fire protection system for fire code compliance.

2. Exit signs: Shall be placed at doors and/or exit ways that open to areas exterior from each recruiting office. Signs shall be hardwired, UL listed, have 6” H lettering with backup batteries which shall provide at least 1-1 / 2 hours of power to light as per NFPA 101. Mounting: Must be capable of ceiling, wall, or end mounting; either single or double faced as required. The sign must utilize long-life LED lamps and self-diagnostics.

3. One, 10-lb. ABC Dry-Chemical Fire Extinguisher with Semi-Recessed Protective White Cabinet: Shall be installed within each military recruiting office, and in rear common area. Location of these units will be coordinated with the COE representative. Mounting height of protective cabinet should be 48” to 52” AFF (or as dictated by local building code regulations) with maximum travel distance to fire extinguisher of 75 feet.

4. Dual Sensor Photoelectric / Ionization Smoke and Fire Detector-Alarm: The Lessor shall ensure the location and installation of all smoke detectors are in accordance with manufacturer’s recommendations for coverage area. At a minimum, at least one hardwired, 120-volt smoke detector with lithium battery backup and test function shall be installed in each military recruiting office and common area, The alarm will be UL approved and capable of emitting an audible alarm of at least 85 dB at 10 feet.

5. Fire Dept. Access Lock-box: Where required for rapid emergency access, COE and Lessor shall coordinate to provide access keys to Government leased premises.

G. Architectural Finishes-Fixtures-Supplies: Ceilings / Walls to be finished according to the following standards for the required Level 5 finish:

1. Gypsum Association GA-214 Standards.

2. Painting & Decorating Contractors of America (PDCA / PCA) Standard P1.

3. Ceilings: Office ceilings shall be 9 feet or no more than 11 feet, from floor to lowest obstruction.

a. Existing: It will be the Lessor’s responsibility to consult with the COE’s on the acceptability of the style of the buildings existing ceiling system. If found acceptable, all ceiling tiles that are damaged, stained or sagging shall be replaced. If matching tiles cannot be found, or if replacement exceeds 50%, then all ceiling tiles shall be replaced and meet the standard for new ceilings.

b. New: A suspended ceiling system with acoustical tile panels shall be installed. It will be a 2’ x 2’ revealed pattern on an exposed 2’ x 4’ grid with 2’ x 4’ ceiling tile (tegular-revealed) panels. The ceiling panels and grid to be white. All panels shall have a noise reduction coefficient (NRC) of not less than .65 in accordance with ASTM C-423.

c. Restrooms: Ceiling to be ⅝” gypsum wallboard, taped and sanded, with a Level 5 finish.

4. Walls:

a. Demising and Mechanical Room: Walls separating government leased premises from adjacent tenants and interior walls enclosing mechanical facilities will be erected from floor to building understructure. It shall be constructed of ⅝”, Type “X” gypsum wallboard, taped and sanded, with a Level 5 finish, applied over 3-⅝” metal studs, 16” o.c. In lieu of; Option #1: Steel chain link fence may be substituted for gypsum wallboard for wall sections above the finished ceiling line. Option #2: Open, 3-⅝”, 25ga. (minimum) studding, 6” o.c., reinforced horizontally @ 24” o.c. maybe used without chain link fence or drywall installation above finished ceiling line.

b. Separation of Individual Military Service Office(s): Walls separating collocated Military Service offices and common areas shall extend from finished floor to 12” above finished ceiling. Construction shall be of 3-⅝” metal studs 16” o.c. with ⅝” gypsum wallboard, taped and sanded, with a Level 5 finish. See paint schedule for wall colors.

c. Standard Interior Office Partitions: Walls shall extend from finished floor to finished ceiling. Construction shall be of 3 ⅝” metal studs 16” o.c. with ⅝” gypsum wallboard, taped and sanded, with a Level 5 finish. See paint schedule for wall colors.

d. Sound-Proofing: Sound attenuating batts with a minimum Sound Transmission Class (STC) of 45, when tested in accordance with ASTM E-336, shall be inserted in all demising and internal walls.

e. Accent Walls: Will be as specified on the floor plan / AE drawing and as referenced on the specific Military Service paint-finish schedule.

PAINT SCHEDULE

General Painting Notes:

· See General Standards paragraph G for requirements, inspect drywall finish prior to painting to ensure a Level 5 finish.

· For individual Military Service, see the specific Military Service Attachment-Paint Schedule.

COMMON AREA & RESTROOMS PAINT SCHEDULE

Mfr:
Color Name:
Color #:
Product:
Coats:
Finish:
Area:

Sherwin Williams

PRIMER
ProMar 200

White (see Note 1)

B28W02600
2
Latex:

Acrylic Primer All Walls / All Painted Trim

Sherwin Williams Common Area & Restroom Walls Worldly Gray

SW 7043

Worldly Gray

B20W12651
2
Latex: Eg-Shel
Walls (Restroom &

Common Areas)

Sherwin Williams Common Areas & Restrooms Trim Worldly Gray

SW 7043

Worldly Gray

B31W2651
2
Latex: Semi-Gloss
Trim (Restroom &

Common Areas)

Sherwin Williams Common Area Chair Rail Mega Greige

SW 7031

Mega Greige

B31W2651
2
Latex: Semi-Gloss
Chair Rail

(Common Areas)

Sherwin Williams Standard Ceiling Finish White Standard White Ceiling Finish

Standard
2
Latex: Eg-Shel
Ceiling

(Restroom)

Note 1: ProMar 200 Primer to be tinted to match the applicable wall color for all walls, and all painted trim.

Note 2: For individual Military Service paint-finish schedule, see specific Military Service Attachment-Paint Schedule.

Note 3: All window and door frames shall have semi-gloss finish; color to be: Worldly Gray SW 7043.

Note 4: Chair Rail to be: Mega Greige SW 7031

Note 5: Restrooms to be: Worldly Gray SW 7043

Note 6: Gypsum Wallboard Ceilings (where applicable) to be: Standard White Ceiling Finish

Note 7: If selected, contractor should request Sherwin Williams’ colors as listed above for common areas.

Formulas to these colors are available on Sherwin Williams’ National Accounts Database.

f. Porcelain Wainscot Wall Tile (Restroom): Wall tiles shall be installed per ENCLOSURE #2, including ordering instructions, typical wainscot pattern, including tile, transitions, and grout color designations.

g. Fiberglass Wall Panels (Janitorial Closet): Shall be installed to full-wall-height on all janitorial closet walls. Panels to be standard white, Class C, Fiberglass Reinforced Plastic (FRP). Panel performance to comply with ASTM E-84.

5. Flooring: General parameters: All floor areas will be of a common level, finished in a specified material and have a minimum live-load capacity of 50 pounds per square foot.

a. Porcelain Entry Tiles (Front / Rear Exterior Exits as necessary): Porcelain tile with unpolished, non-slip surface shall be installed at the interior side of exterior / exit entrance doors for recruiting offices located in a 4-season climate zone. See ENCLOSURE #2, including ordering instructions, for a typical floor tile pattern, including tile color / name, grout color / name, and tile transition designations. Military Service facility front entrance tile area shall be approximately 4’ L x 5’ W (with one foot on each side of the door width), see where applicable. See specific Military Service Attachment for their requirements.

b. Lobby- Front / Rear Exterior Exit-Corridor and Restroom Areas: Porcelain tile with unpolished, non-slip surface shall be installed in the lobby, exit, corridor, security closets (connected to common area hallways), and restroom area floors. See ENCLOSURE #2, including ordering instructions, for a typical floor tile pattern, including tile color / name, grout color / name, and tile transition designations. See specific Military Service Attachment for their requirement.

c. Storage areas: Vinyl Composition Tile (VCT) with base cove shall be installed in storage areas. Note: See specific Military Service Attachment for requirements.

d. Base Cove (for VCT & Carpet only): Note: See specific Military Service Attachment for requirements.

e. Janitorial-Mechanical room(s): Exposed concrete with non-slip floor sealer.

Base Cove: Johnsonite / Tarkett (https://distributor.tarkett.com), Rubber; Color: #40, Black, 4” H.

f. Carpet Schedule by Military Service (Office, test room and related areas): For individual Military Service requirements, see the specific Military Service Attachment’s Carpet Schedule.

6. Windows:

a. Exterior: Windows shall be weather tight and if operable, shall be equipped with lock assemblies. Window unit(s) that cannot be secured must be replaced.

1. Existing Laminated Glass - IMPORTANT: Lessor will confirm that all glass meets the following minimum requirements: a nominal ¼” thick laminated glass pane fabricated from two pieces of nominal ⅛” thick glass bonded together with a minimum 0.030” polyvinyl butyral (PVB) interlayer. If the window contains an insulating glass unit (IGU), then the innermost lite must be the laminated glass noted above and the outer lite may be monolithic glass. If the Lessor is unable to provide written confirmation that the existing glass meets this requirement, then glass fragment retention film must be installed as indicated below. With written confirmation from the Lessor / contractor stating laminated glass is present (on ALL windows / doors that are on the perimeter of the Government’s leased premises, regardless of the window being to the outside air or a shared common space with other tenants) and meets the required standards above, fragment retention film is not required.

2. Glass Fragment Retention Film - IMPORTANT: Without written confirmation of laminated glass installed, all glass in exterior windows and doors shall have fragment retention film applied to the interior (room) side in accordance with manufacturer's instructions by a certified installer. Fragment retention film can be either optically clear or, if approved by Lessor, with a light gray tint or a reflective surface. Film shall be 3M Safety & Security Window Film, series type Ultra S800 or Ultra Prestige S50. Film may be substituted that meets or exceeds the specified films (along with manufacturer’s flexible-mechanical or structural silicone adhesive anchoring systems), with prior approval of COE. Film shall be attached to the interior frame on all four (4) sides using an anchoring system in accordance with the manufacturer’s instructions for the chosen system. The anchoring system must use 3M Impact Protection Profile BP700 Attachment System, a flexible-mechanical, pre-molded profile strip with adhesive “legs”. If the flexible-mechanical method is unacceptable to Lessor, then the anchoring system shall use the 3M Impact Protection Adhesive structural silicone adhesive. Under NO circumstances are standard sealant or caulk compounds to be utilized for adhesive anchoring of the film. Note: If used, the structural silicone adhesive color shall complement existing framing system and adhesive shall be applied only after the window has been masked with 1” blue “safe release tape” applied to both film and window frame to assure clean, gasket-like appearance when tape is removed. For ‘wooden window / door frame systems’, an anchoring system need not be applied to glass fragment retention film edges (daylight application). If selected, for installation, government pricing-expedited delivery is available from; Window Film Depot, P.O.C. Jeff Franson, 866-933-3456; email: jeff@windowfilmdepot.com.

3. Mini-Blinds: NOT TO BE INSTALLED ON ANY EXTERIOR WINDOWS OR DOORS.

4. Roller Shades: See Para. G.9.a.1. (below).

5. Perforated Window Wraps: See Para. G.9.b.

b. Interior:

1. Windows: A 3’-0” H x 4’-0” W fixed, glass window set in metal frame shall be installed in interior walls of hallways and recruiter-in-charge office(s) at a height of window frame approximately 42” AFF. Note: Ganged windows along hallways are acceptable. These windows shall meet all safety code requirements and be equipped with mini-blinds that meet standards referenced in G.9.c. (below).

2. Test Room(s): Except for the Marine Corps, test rooms shall have an individual window(s) as indicated on the floor plan / AE drawing. Mini-blinds are not to be installed for these windows.

3. Window Frames: Window frames shall match interior door frames in color, style, and material. See para. G.7.b. Interior Finish for guidance.

4. Mini-Blinds (interior windows / doors only, except test rooms): See Para. G.9.c.

7. Doors:

a. Exterior: All exterior doors shall be weather-tight, with Grade 1 hardware, anti-pry plate / latch bolt protector, and with finish to match existing store front. If existing, any double-door entrance will be eliminated either by a permanent one-door, lock down or by a complete replacement to a single-door entry system. Note: Reduction in exit width shall be compliant with all building / fire code requirements. Additionally, if removable, all door hinge pins exposed to the outside exterior of the office premises will be secured to prevent manual removal.

1. Fragment Retention Film: The Lessor will confirm and provide written confirmation that the existing glass in doors meets the minimum laminated glass requirements identified in Para. G.6.a above or else fragment retention film must be installed. When required, the fragment retention film for exterior glass doors shall be installed.

2. Fixed Panel Shade: See paragraph G.9.a.1.ii below for details.

3. Main entrance: Doors shall be equipped with dead-bolt lock-set, automatic door closer and entry alert door chime system. (See para. D.5. entry bell and para. K.1. video access control system requirements).

4. Secondary Exits: Steel doors and frames are required unless building aesthetics / standards only allow glass / other door types. Doors shall be equipped with the following: an automatic door closer with a dead bolt panic bar assembly; Securitech, Model: #TEL-200F, TEL-KLT-AP, TEL-EP1; entry alert door chime system (see para. D.5. entry bell) and a model number Nuk3y - 220 degree wide angle heavy duty door viewer (peephole) in satin nickel ~ approximate installation height to be 5’-0” AFF. Door viewer to have optics which will provide a sharp and clear view to the exterior side of the exit door. Note: If glass doors are present, an Adamsrite 8800 Series (Life Safety) Narrow Stile Starwheel Rim Exit Devise (panic bar) is to be used (replaces the Securitech model), along with all additional door security components.

5. Anti-Pry Plate (aka Security Latch Guard): Install a stainless steel anti-pry plate that is a minimum of: 12 gauge thickness, 10” L, and 3.25” W. Mounting studs shall be concealed welded on the back side of the security plate thereby leaving no point of attack from the building exterior. Note: Anti-Pry plate provided must conform to existing door configuration (e.g., offset, door handle, etc.).

6. Keying or Re-Keying: Before delivery and acceptance of the premises, all previous existing exterior door-locks shall be re-keyed. The Lessor will be responsible for coordinating with the COE on the number of new keys required to be furnished to each Military Service. (Note: Both front and rear exterior exit doors should be same-keyed.) EACH individual Military Service office shall be separately keyed. Keys to be minimized / same-keyed for each Military Services front and rear exit (interior and exterior doors), security closet and each Military Service specific interior doors (excluding Station Commanders Offices). Station Commanders Offices shall be separately keyed. See also paragraph A.4 regarding the number of recruiters needing keys.

7. Mini-blinds NOT to be installed on exterior windows or doors.

b. Interior: All interior doors will be a solid-core, flat panel, maple veneer, pre-hung wood unit with metal door frame with convex door bumper. Hardware sets including a door lever profile similar or equal to Hager, style; ‘August’, shall be Grade 2 or better with brushed, stainless steel finish or finish to comply with existing standards.

1. See also paragraph G.7.a.6 for keying details, and A.4 regarding the number of recruiters needing keys.

2. All interior doors shall be a minimum thickness 1-¾”, solid core, 36” x 80”.

3. Finish:

i. Frames (for doors & windows) to be as referenced within each Military Services Paint Schedules (except Air Force in paragraphs G.4 and G.5).

ii. Door color to be stained MinWax, Red Chestnut #232 (on all sides). Two (2) coats of polyurethane matte finish to be applied to stained areas.

iii. All interior door frames to match interior window frames in style and finish.

4. Main Access to each Military Service, Recruiter-in-charge interior office(s) and Test Rooms to have full-length glass door.

5. Mini-blinds to be installed on interior doors (except test rooms): See Para. G.9.c.

6. If applicable, any secondary Military Service access door from each office into Government controlled common area space shall have a model number Nuk3y - 220 degree wide angle heavy duty door viewer (peephole) in satin nickel, ~ approximate installation height to be 5’-0” AFF.

7. The following hardware schedule shall apply:

INTERIOR DOOR HARDWARE SCHEDULE

Hardware Grade No. 2 or better:
Solid Core:
Minimum Size:
Hardware Set:
Interior Entry / Exit Doors (w/in Gov’t controlled leased premises)
X
36”x80”
D
Test & Interview Rooms
X
36”x80”
E
Private Offices
X
36”x80”
B
Storage Room
X
36”x80”
B
Security Closet
X
30”x80”
B
Janitorial Closet
X
36”x80”
A
Restrooms
X
36”x80”
C
Mechanical Room (if applicable)
X
36”x80”
D

Hardware Set Descriptions:

A: Dead bolt lock with interior thumb latch.

B: Standard with key lock (single-cylinder).

C: Thumb latch.

D: Standard key lock with dead bolt (both single-cylinders).

E: Standard (passage) door set - without lock.

NOTE: Lessor will be responsible for coordinating with COE on the number of keys Required to be furnished for each Military Service. See also paragraph A.4 regarding the number of recruiters needing keys.

8. Restroom Fixtures, Accessories and Miscellaneous: Shall contain the following:

a. Faucet(s) to be a hardwired touchless, finish to be stainless steel (SS).

b. Toilet flush valves to be a hardwired touchless, finish (SS).

c. Urinal flush valves to be a hardwired touchless, finish (SS).

d. Foam soap dispenser to be a hardwired touchless, wall mounted - finish (SS).

e. Mirror (above sink) with shelf – finish (SS).

f. Dual-roll toilet paper dispenser – finish (SS).

g. Commercial grade, stand alone, waste receptacle – finish (SS).

h. Commercial grade, hardwired wall mounted, touchless hand-dryer – finish (BSS). Hand-dryer to be equal to or better than Xlerator Model # XL-SB.

i. Urinal screen and/or toilet partition panels – finish (SS).

j. Sanitary napkin waste receptacle, wall mounted (Unisex, Women’s restroom) – finish (SS).

k. Coat hooks: inside face of each water closet stall door and wall mounted adjacent to lavatories and/or where appropriate – finish (SS).

l. Exhaust fan; 100cfm minimum or as required by code; sound level <2.0 sones.

m. GFI electrical outlet adjacent to mirror / sink.

n. If existing, restrooms to be updated with all appropriate paint, tile, fixtures, etc.

9. Miscellaneous:

a. Exterior Windows / Doors:

1. Roller Shades: ALL exterior windows shall have roller shades installed. WHEN INSTALLED, SHADES SHALL NOT ALLOW FOR ANY VISUAL GAPS.

i. Roller Shades (windows only): The Lessor will coordinate with the COE as to whether single roller shades are required. Single or Dual shades to be Hunter Douglas, Contract Roller Shade: Model #RB500 or equivalent. Fascia & End Cap finishes to be “anodized aluminum”. These shades will not require military logos. To ensure a uniform appearance, all window shades will be motorized, with an appropriate electric wall switch control(s) as identified on the floor plan / AE drawing. Roller Shade couplers will be used to minimize the number of motors and electrical drop(s) required (up to 300” in length and/or 6 roller shades). All electrical power to be hardwired within conduit inside walls. Shades shall NOT be installed inside the window frame (in order to connect multiple roller shades together with a single motor). Motor to be, Sonesse Ultra model # 50 RA with a sound level equivalent to an office conversation. Installation shall be as per manufacturer’s written instructions ~ to include all necessary blocking and structural supports. Shades to include the required number of Individual Group Control (IGC) 4N1 motor controls with a HARDWIRED DecoFlex Dry Contact Keypad / Switch. Keypad / Switch to have the appropriate number of channels to address any potential variety of multiple shade zones ~ dependent on floor plan / AE drawing layout. NOTE: BATTERY OPERATED KEYPADS ARE NOT ALLOWED. Shades will have a lifetime warranty and pass the NFPA 701 Small Scale test. If window(s) cannot be equipped with roller shades, either because of their unique shape and/or the inability to install the shade correctly, then only with expressed prior approval of the COE, a fixed panel shade shall be applied in accordance with fixed panel specifications below. If already installed, existing glass block requires no window covering. For wiring diagrams, see ENCLOSURE #3 and ENCLOSURE #4.

· Single Roller Shades (windows only): Privacy shade shall be a fabric equal to Hunter Douglas SheerWeave 7100, color White. If the 7100 fabric is not available, the SheerWeave 7400 fabric (color: Cotton), is acceptable. To be installed when an exterior perforated window wrap IS INSTALLED / WILL be applied to the exterior windows (Lessor to coordinate with the COE). See Para G.9.b. for Perforated Window Wrap guidelines.

· Dual Roller Shades (windows only): Dual Roller shades will be installed when an exterior perforated window wrap IS NOT or WILL NOT be applied to the exterior windows. Shades to have both ‘Sheer’ and ‘Privacy’ fabrics. The ‘Sheer Shade’ shall be of a fabric equal to Hunter Douglas E Screen color, White / White with an openness factor of 3% and shall be closest to the window. The ‘Privacy Shade’ shall be fabric equal to Hunter Douglas SheerWeave 7100, color White. Note: If a dual shade application is required, it may be necessary to install two individual shades if existing window conditions do not allow enough room to accommodate a dual shade bracket.

ii. Fixed Panel Shades: All exterior glass entrance doors shall have a fixed panel shade installed on the interior side of the glass. This fixed panel shade shall include:

· Fixed panel shades to be Hunter Douglas Contract Shade: Model #RB500 or equivalent.

· Shade shall be a sheer fabric equal to Hunter Douglas E Screen color, White / White with an openness factor of 3%.

· Fixed panel shall have a thread reinforced welded pocket.

· Attachment anchoring system to be clear anodized aluminum rods, mounted with fixed rod mount in a silver finish using # 8 stainless screws and be affixed to the door frame.

· Shade shall eliminate all light gaps with a minimum of ½” overlap.

· Door(s) shall receive separate top and bottom panels. The top panel to cover all exposed glass above the door handle. The bottom panel to cover all exposed glass below the door handle. If no door handle exists, two separate panel shades are also to be installed for stability.

· Any sidelight or transom windows adjacent to door(s) too narrow to receive roller shade(s) or unable to be effectively covered by specified roller shade(s) shall receive a single fixed panel shade as described above.

· Installation shall be as per manufacturer’s written instructions.

· See ENCLOSURE #5 for typical pictures and installation drawings for the fixed panel shades. This enclosure includes Hunter Douglas drawing specification number references which will ensure proper materials are ordered.

iii. If selected, for installation and government pricing-expedited delivery: Hunter Douglas Contract division; P.O.C. Nichole, 1-800-417-3248; email: armycorpsorders@hunterdouglas.com. Installation video can be found at the following link: https://www.youtube.com/watch?v=DEWBwhFNIaI

b. Perforated Window Wraps: The application of perforated window wraps is dependent upon the type of facility, along with other requirements. COE representative / Military Service(s) shall have control over what graphic is applied, what position the graphic will be placed and on which windows. Lessor / contractor will coordinate with the COE representative.

1. Stand-Alone OR Collocated with Separate Entrance Doors: Install perforated window wrap with appropriate Military Service(s) graphic on the exterior of all storefront glass. Perforated window wrap installations shall have 100% coverage of all exterior glass, including common areas (see individual Military Service graphic requirements). The Graphic below is provided for example purposes ONLY. The COE Representative to provide the appropriate link for each Military Services graphic (all appropriate files to be downloaded by contractor for use).

Example Only – COE to Provide Specific Graphics.

2. Collocated with a Shared Entrance Door (JRFC Graphic): When multiple Military Services are present and they share the same entrance door, a “JRFC Graphic” will be installed. Perforated window wrap installations shall have 100% coverage of all exterior glass, including common area windows (if applicable). If Military Service “exclusive” windows on the sides or rear of the premises (not front windows) are present, individual Military Service graphics can be applied to those windows (coordinate with the COE Representative). The JRFC Graphic image shown below is provided for reference purposes ONLY. This image will be included in a PDF “Style Guide” that the contractor MUST download with detailed instructions. The image needs to be put together with specified materials and look as close to the below image as possible. In the Style Guide, the black lines represent window / door mullions. The COE representative will provide a link and folder name for the contractor to download ALL appropriate files necessary (36 in total) to create / install the JRFC Graphic:

Example Only – COE to Provide Link for Specific Graphics.

3. The Lessor will provide all graphics examples and mockup elevations for COE approval, and when chosen, provide final proofs and storefront elevation renderings of the approved graphics.

4. The approved graphic(s) shall meet the following standard(s) or equivalent on all storefront window wrap applications (including all manufacturer installation requirements MUST be followed, especially for temperatures, for the installation of all perforated exterior graphics):

i. 3M, 8170 – P40 (40% perforated), 4-mil, opaque, cast vinyl film with a high gloss finish.

ii. Window graphic film will have a visual obscurity density of 60 / 40.

iii. Apply 3M Scotchcal Optically Clear Gloss Overlaminate (8518) and shall be laminated prior to installation.

iv. Apply 3M edge sealer tape 8914 at time of installation to all edges of the perforated film to prevent pealing.

5. The Lessor will coordinate with the COE representative regarding the correct graphic. The following are the types of graphics that might be installed at a location (as indicated in #1 and #2 above), and in rare cases both could be installed.

i. Military Service Individual Graphics (Stand-alone OR Collocated with separate entrance doors).

ii. JRFC Graphic (Collocated with shared entrance door for all Military Services).

6. Note: Only the COE representative will make the final decision on the approved graphics.

c. Interior Windows / Doors:

1. Mini-Blinds: All interior windows and glass doors (except test rooms) shall be equipped with mini-blinds having non-corroding mechanisms and synthetic tapes. Each window shall have its own individual mini-blind.