FY21 490407 HOOD DFAC BLDG 56471 RTA DRAWING SUBMITTAL.pdf
PDF 42 MB Posted
- Attached to
- Repair B56471 Classroom Re-purpose Federal contract opportunity
- Solicitation number
- W9126G21B4574
About this file
This document provides details for a federal construction solicitation. The solicitation number is W9126G21B4574 and seeks a contractor to renovate and repurpose an existing dining facility building (B56471) at Fort Hood into a general use classroom. The work includes renovating and updating the building systems and layout to accommodate its new purpose. The solicitation was issued by the Department of the Army Corps of Engineers Engineering District Fort Worth. Responses are due based on the standard FAR construction solicitation timeline and procedures.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Repair B56471_Bid Abstract_FY21.pdf | ||
| am_03.pdf | ||
| am_02.pdf | ||
| Bldg. 56471 Site Visit Roster.pdf | ||
| am_01.pdf | ||
| 1978 B56471 AsBuilts Compiled.pdf | ||
| 2008 B56471 AsBuilts Compiled.pdf | ||
| 2011 B56471 AsBuilts Compiled.pdf | ||
| 2014 B56471 AsBuilts Compiled.pdf | ||
| W9126G21B4574.pdf | ||
| 2009 B56471 AsBuilts Compiled.pdf |
Show all 11
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
REPURPOSE DFAC BUILDING 56471
FORT HOOD, TEXAS
FY21 PN: 490407
FO
R
T H O
O D
, TEXAS
U.S. ARMY CORPS
OF ENGINEERS
FORT WORTH DISTRICT
DATED: APRIL 2021
SIGNATURES AFFIXED BELOW INDICATE
OFFICIAL RECOMMENDATION AND APPROVAL OF
ALL DRAWINGS IN THIS SET AS INDEXED ON THIS SHEET.
APPROVAL RECOMMENDED BY:
CHIEF, ENGINEERING BRANCH DATE
R
EPU
R
PO
SE D
FAC
BU
ILD
IN
G
56471 FY21 PN
: 490407
R
EP
U R
PO
SE
D
FA
C B
U
IL
D
IN
G
FY
P N
: 4
FO
R
T H
O O
D , T
EX
ASThis project was designed by the Fort Worth District of the U.S. Army
Corps of Engineers. The initials or signatures and registration designations of individuals appear on these project documents within the scope of their employment as required by ER 1110-1-8152
SOLICITATION NO.: W9126G21B4574
4 August 2021
SHEET
NUMBER
D ra w n by
D es ig ne d by
Su bm itt ed b y:
Sh ee t S iz e
AN
SI
D
D at e:
C on tra ct
N o.
So lic ita tio n N o.
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
FO
R
T W
O R
TH
D
IS
TR
IC
T
TA
YL
O R
S
TR
EE
T
FO
R
T W
O R
TH
, T
EX
AS
C he ck ed b y:
US Army Corps of Engineers ®
A
R ev
M ar k D es cr ip tio n Tr ac ki ng N o.
Ac tio n
D at e
EN
G
IN
EE
R
IN
G
C O
N
ST
R U
C
TI
O N
D
IV
IS
IO
N
EN
G
IN
EE
R
IN
G
B R
AN
C
H
PLOT DATE:
2 3 4 5 6 7 8 9 10
B
C
D
E
F
G
Fort Worth District
FILE PATH:
4/27/2021 4:26:08 PM
FO
R
T H
O O
D , T
EX
AS
R
EP
U R
PO
SE
D
FA
C B
U
IL
D
IN
G
TO
C
LA
SS
R O
O M
F
AC
IL
IT
Y
PN
: 4
AP
R
IL
P.
C
AM
AC
H O
P.
C
AM
AC
H O
PA
U
L J.
G R
IN
D
EL
, P
.E
D
EP
U
TY
C H
IE
F, E N
G R
B R
AN
C
H
G-002
IN
D
EX
O
F D
R
AW
IN
G
S K.
H
IL
L
Project Name
INDEX OF DRAWINGS
CIVIL
CU101 GREASE TRAP LOCATION PLAN
CS101 FIRE LANE MARKING PLAN
C-501 CONCRETE PAVEMENT DETAIL
GENERAL
G-001 COVER SHEET
G-002 INDEX OF DRAWINGS
G-003 PROJECT LOCATION PLAN
STRUCTURAL
S-001 GENERAL STRUCTURAL NOTES AND DETAILS I
S-002 GENERAL STRUCTURAL NOTES AND DETAILS II
S-003 GENERAL STRUCTURAL NOTES AND DETAILS III
SD-100 FOUNDATION DEMOLITATION PLAN
S-101 FOUNDATION PLAN
S-121 MISCELLANEOUS DETAILS I
S-122 MISCELLANEOUS DETAILS II
ARCHITECTURE
A-001 ABBREVIATIONS, LEGENDS AND ANNOTATION STANDARDS
A-002 ACCESSORIES AND FIXTURES MOUNTING HEIGHTS
AD101 DEMOLITION - FLOOR PLAN
AD102 DEMOLITION - RCP
AD103 DEMOLITION - ROOF PLAN
AD104 DEMOLITION - ELEVATIONS
A-101 FLOOR PLAN
A-131 REFLECTED CEILING PLAN
A-151 ROOF PLAN
A-201 EXTERIOR BUILDING ELEVATIONS
A-301 BUILDING SECTIONS
A-311 WALL SECTIONS I
A-312 WALL SECTIONS II
A-401 ENLARGED PLANS / ELEVATIONS I
A-402 ENLARGED PLANS / ELEVATIONS II
A-403 ENLARGED PLANS / ELEVATIONS III
A-404 ENLARGED PLANS/ ELEVATION IV
A-511 PLAN DETAILS
A-521 ROOF DETAILS I
A-522 ROOF DETAILS II
A-601 DOOR SCHEDULE
A-602 DOOR DETAILS I
A-603 DOOR DETAILS II
A-611 WINDOW SCHEDULE AND DETAILS
A-612 WINDOW AND LOUVER DETAILS
A-621 PARTITION TYPES
A-631 UL DETAILS FIRE SAFING AND FIRE STOPPING
A-641 EXTERIOR SIGNAGE DETAILS
A-701 INTERIOR DETAILS I
A-702 INTERIOR DETAILS II
A-703 INTERIOR DETAILS III
A-721 CASEWORK I
A-722 CASEWORK II
A-820 ENLARGED STAIR DETAILS
INTERIORS
I-101 FURNITURE FLOOR PLAN
I-601 INTERIOR FINISH PLAN
I-611 SIGNAGE SCHEDULE
FIRE ALARM
FA001 FIRE ALARM LEGEND
FA101 FIRE ALARM PLAN
FA501 FIRE ALARM DETAIL1
FA502 FIRE ALARM DETAIL 2
FA601 FIRE ALARM RISER DIAGRAM
FA602 FIRE ALARM MATRIX
FA603 STANDARDIZED FORT HOOD DPW ZID
MECHANICAL
M-001 MECHANICAL LEGEND
MD101 OVERALL MECHANICAL DEMOLITION PLAN
MH101 OVERALL HVAC PLAN
MP101 OVERALL HYDRONIC PLAN
M-401 ENLARGED MECHANICAL ROOM PLANS
M-501 HEATING WATER SCHEMATIC
M-502 CHILLED WATER SCHEMATIC
M-503 MECHANICAL DETAILS
M-504 MECHANICAL DETAILS
M-505 MECHANICAL DETAILS
M-601 MECHANICAL SCHEDULES
M-602 MECHANICAL SCHEDULES
M-603 MECHANICAL SCHEDULES
M-901 MECHANICAL ROOM ISOMETRIC
MI001 CONTROLS LEGEND
MI002 POINTS LIST INSTRUCTIONS
MI301 AHU CONTROLS SCHEMATIC
MI302 AHU POINTS LIST
MI303 AHU SEQUENCE OF OPERATIONS
MI304 AHU LADDER DIAGRAM
MI305 VAV TERMINAL UNIT SCHEMATIC
MI306 VAV POINTS LIST
MI307 TYPICAL FCU CONTROLS
MI308 CHILLED WATER SYSTEM SCHEMATIC
MI309 CHILLED WATER SYSTEM POINTS
MI310 HYDRONIC HOT WATER SYSTEM SCHEMATIC
MI311 HYDRONIC HOT WATER SYSTEM POINTS
MI312 DOMESTIC HOT WATER CONTROLS
MI313 EXHAUST FAN CONTROLS
MI314 OTHER SYSTEM CONTROLS
ELECTRICAL
E-001 ELECTRICAL LEGEND
ED101 DEMOLITION PLAN
EG101 LIGHTNING PROTECTION PLAN
EG501 GROUNDING DETAILS 1
EG502 GROUNDING DETAILS 2
EG503 GROUNDING DETAILS 3
EG601 GROUNDING RISER DIAGRAM
EL101 LIGHTING PLAN
EL501 LIGHTING DETAILS 1
EL502 LIGHTING DETAILS 2
EL503 LIGHTING DETAILS 3
EL601 LIGHTING FIXTURE SCHEDULE & CONTROL MATRIX
EP101 POWER PLAN
EP401 ENLARGED ELECTRICAL & TELECOMM ROOMS
EP601 POWER RISER DIAGRAM
EP700 MECHANICAL EQUIPMENT SCHEDULE
EP701 PANEL SCHEDULE 1
EP702 PANEL SCHEDULE 2
ET101 TELECOMMUNICATION PLAN
ET501 TELECOMMUNICATIONS DETAILS 1
ET502 TELECOMMUNICATION DETAILS 2
ET503 TELECOMMUNICATIONS DETAILS 3
ET601 TELECOMMUNICATION RISER DIAGRAMLIFE SAFETY
LS001 LIFE SAFETY PLAN CODE CRITERIA
LS101 LIFE SAFETY PLAN
LS102 LIFE SAFETY PLAN DETAILS
PLUMBING
P-001 PLUMBING LEGEND
PD101 OVERALL PLUMBING ABOVE-SLAB DEMOLITION PLAN
PD102 OVERALL BELOW-SLAB DEMOLITION PLAN
PL101 SANITARY WASTE AND VENT PLAN
PP101 DOMESTIC HOT AND COLD WATER PLAN
P-501 DOMESTIC COLD WATER SYSTEM SCHEMATIC
P-502 PLUMBING DETAILS
P-503 PLUMBING DETAILS
P-601 PLUMBING SCHEDULES
P-901 ADMIN RESTROOM DOMESTIC WATER ISOMETRIC
P-902 ADMIN RESTROOM SANITARY WASTE AND VENT ISOMETRIC
P-903 VESTIBULE RESTROOM PLUMBING ISOMETRIC
FIRE PROTECTION
FX101 FIRE PROTECTION FLOOR PLAN 1ST FLOOR
FX500 FIRE PROTECTION DETAILS
W
G
B4
16TH ST
A V
E N
U E
V
E N
V
E N
V
E N
B
V
E N
C
V
E N
F
V
E N
V
H
P A
R K
E N
U E
C E
N T
R
L
E
C E
N T
R
E
AV
EN
U E
T
S
S T
T
H
S t
24TH St
24TH St
15TH St
16TH St
17TH St
18TH St
21ST St
18TH St
T
H
S t
16TH St
15TH S
t
TH
St
T
H
S t
T
H
S t
T
H
S t
T
H
S t
T
H
S t
T
H
S t
T
H
S t
T
H
S t19
T H
S t
T
H
S t
T
H
S t
T
H
S t
T
H
S t
T
H
S t
T
H
S t
T
H
S t
T
H
S t
6T
H
S t
R
D
S t
N D
S t
N D
S t
1S
T
S t
R
D
S t
21ST St
21ST St
23RD St 23RD St
18TH ST
18TH ST
P A
E
P A
E
1S
T
S T
23RD ST
16TH ST
A V
E N
G
V
E N
V
E N
V E
N
V
E N
D
V
E N
V
E N
V
E N
V
E N
V
E N
E
N T
R
E N
U E
H
EAD
Q U
AR
T
ER
S
AV
EN
U E
C E
N T
R
E
C E
N T
R
E
C E
N T
R
E
C E
N T
R
E N
U E
P A
E N
U E
P A
E N
U E
P A
E N
U E
P A
E N
U E
H
EAD
Q U
AR
T
ER
S
AV
EN
U E
H
EAD
Q U
AR
T
ER
S
T
H
S T
T
H
S T
T
H
S T
S
T
H
S T
P B
P B
P B
P B
P B
3P B
P B
P B
H E
A L T
H
C L
IN
IC
T E
M
Q
IP
C
P a v ilio n
P B
P B
P B
P B
57104 57131
71D
MATES Pond 3
70A
MATES Pond 1
MATES Pond 2
SHEET
NUMBER
D ra w n b y
D e s ig n e d b y
S u b m it te d b y
S h e e t
S iz e
A N
S I
D
D a te
C o n tr a c t
N o
S o li c it a ti o n N o
F O
R T
W O
R T
H D
IS
T
R
IC
T
F O
R T
W O
R T
H
T E
X A
S
C h e c k e d b y
US Army Corps of
Engineers ®
A
R e v
M a rk
D e s c ri p ti o n
T ra c k in g N o
A c ti o n
D a te
E N
G
IN
E E
R
IN
G
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
E N
G
IN
E E
R
IN
G B
R A
N C
H
PLOT DATE:
2 3 4 5 6 7 8 9 10
B
C
D
E
F
G
Fort Worth District
FILE PATH:
1/15/2019 12:39:43 PM
Enter Project Name
C H
IE
F
C
IV
IL
S E
C T
IO
N
B R
A N
T E
JE
N S
E N
P
.E
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
T
A Y
L O
R S
T
A P
R
IL
P N
T O
C L
A S
S R
O O
M F
A C
IL
IT
Y
R E
P U
R P
O S
E D
F A
C B
U
IL
D
IN
G
N O
R T
H F
O R
T H
O O
D T
E X
A S
P R
O
JE
C T
L O
C A
T
IO
N P
L A
N
B
F A
IR
B
F A
IR
D
B R
O W
N
P .E
.N 8T
H S
T
H E
A D
Q U
A R T E
R S A
V E
TH
S
T
G-003
C E
N T R
A L A
V E
WITH THE COR.
CONTRACTOR SHALL COORDINATE FINAL LOCATION
1. LAYDOWN AREA LOCATION IS APPROXIMATE AND
GENERAL NOTES:
© 2021 Microsoft Corporation © 2021 Maxar ©CNES (2021) Distribution Airbus DS
TEXAS HWY 36 ACCESS GATE
PROJECT SITE
LAYDOWN AREA
NN
1000'0 500'
W
G
B4
C I
.5
C I
AC
C I
C I
C I
C I
1" C I
1"
C I
U
N K
N O
W N
6" U
N K
N O
W N
6" U
N K
N O
W N
C I
C I
C I
C I
C I
C I
C I12
C I
C I
.5
C I
.5
C I
C I
C I
.5
C I
C I
C I
W
W
W
W
W
F
F
F
10-3
9-7
10-4
"V
C
6"PVC
6"
A
IP
C
V
C
"V
C
6"VC
V C
V C
6"PVC
6"PVC
P
V C
"V
C
"V
C
V C
V C
8"
8" V
C
V C
1"
1"
V C
V C
1"
R:740.66 I:732.48
172A
R:740.52
I:735.06
172B
R:740.82
I:732.57(NW)
I:731.96(SE)
I:731.71(NE)
R:740.29
I:731.83
I:732.91(SW)
R:739.96
171A
R:741.76
I:735.08
I:741
R:745.
I:739.87
R:745.12
WCO
WCO
WCO
WCO
WCO
WCO
WCO
WCO
WCO
WCO
WCO
WCO
WCO
WCO
WCO
WCO
GT
SHEET
NUMBER
D ra w n b y
D e s ig n e d b y
S u b m it te d b y
S h e e t
S iz e
A N
S I
D
D a te
C o n tr a c t
N o
S o li c it a ti o n N o
F O
R T
W O
R T
H D
IS
T
R
IC
T
F O
R T
W O
R T
H
T E
X A
S
C h e c k e d b y
US Army Corps of
Engineers ®
A
R e v
M a rk
D e s c ri p ti o n
T ra c k in g N o
A c ti o n
D a te
E N
G
IN
E E
R
IN
G
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
E N
G
IN
E E
R
IN
G B
R A
N C
H
PLOT DATE:
2 3 4 5 6 7 8 9 10
B
C
D
E
F
G
Fort Worth District
FILE PATH:
1/15/2019 12:39:43 PM
Enter Project Name
C H
IE
F
C
IV
IL
S E
C T
IO
N
B R
A N
T E
JE
N S
E N
P
.E
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
T
A Y
L O
R S
T
A P
R
IL
P N
T O
C L
A S
S R
O O
M F
A C
IL
IT
Y
R E
P U
R P
O S
E D
F A
C B
U
IL
D
IN
G
N O
R T
H F
O R
T H
O O
D
T E
X A
S
B
F A
IR
B
F A
IR
D
B R
O W
N
P .E
G
R E
A S
E T
R A
P L
O C
A T
IO
N
P L
A N
CU101
BLDG 56471
GREASE TRAP - SEE NOTE
LAYDOWN AREA
SANITARY SEWER LINE
DOMESTIC WATER LINE
SUPPRESSION SYSTEM.
LINE TO THE BUILDING FOR THE NEW FIRE
AMERICAN WATER TO CONSTRUCT A FIRE WATER
3. THE CONTRACTOR SHALL COORDINATE WITH
GREASE TRAP.
EXISTING SEWER PIPING DOWNSTREAM OF THE
AMERICAN WATER TO REMOVE OR ABANDON THE
2. THE CONTRACTOR SHALL COORDINATE WITH
THE EXISTING UPSTREAM PIPING.
OF THE EXISTING GREASE TRAP, AND ABANDON
1. THE CONTRACTOR SHALL REMOVE AND DISPOSE
GENERAL NOTES:
H E
A D
Q U
A R
T E
R S A
V E
TH
S
T
C E
N T R
A L A
V E
NN
80'0 40'
W
G
B4
D ra w n b y
D e s ig n e d b y
S u b m it te d b y
S h e e t
S iz e
A N
S I
D
D a te
C o n tr a c t
N o
S o li c it a ti o n N o
F O
R T
W O
R T
H D
IS
T
R
IC
T
F O
R T
W O
R T
H
T E
X A
S
C h e c k e d b y
US Army Corps of
Engineers ®
A
R e v
M a rk
D e s c ri p ti o n
T ra c k in g
N o
A c ti o n
D a te
E N
G
IN
E E
R
IN
G
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
E N
G
IN
E E
R
IN
G B
R A
N C
H
PLOT DATE:
2 3 4 5 6 7 8 9 10
B
C
D
E
F
G
Fort Worth District
FILE PATH:
1/15/2019 12:39:43 PM
Enter Project Name
C H
IE
F
C
IV
IL
S E
C T
IO
N
B R
A N
T E
JE
N S
E N
P
.E
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
T
A Y
L O
R S
T
A P
R
IL
P N
T O
C L
A S
S R
O O
M F
A C
IL
IT
Y
R E
P U
R P
O S
E D
F A
C B
U
IL
D
IN
G
N O
R T
H F
O R
T H
O O
D T
E X
A S
B
F A
IR
B
F A
IR
D
B R
O W
N
P .E
F
IR
E
L A
N E
M A
R K
IN
G
P L
A N
CS101
BLDG 56471
MARKING AREA (SEE NOTES)
PROPOSED 20' X 13.5' FIRE LANE
GENERAL NOTES:
SHALL BE A MINIMUM OF 18-IN WITH 3-IN LINE WIDTHS.
SPACED 3' ON CENTER AT 45 DEGREE ANGLE. TEXT HEIGHT
PAVEMENT MARKINGS. DIAGONAL STRIPING SHALL BE
3. ALL STRIPING SHALL BE MINIMUM 6-IN THICK LINES, YELLOW
MINIMUM 2' CLEARANCE FROM BUILDING AND RETAINING WALL.
FIRE LANE MARKINGS' OUTER LINE SHALL HAVE A 2.
JURISDICTION.
SIGNAGE APPROVED BY FORT HOOD AUTHORITY HAVING
1. CONTRACTOR SHALL PROVIDE FIRE LANE MARKINGS AND
NORTH EAST EDGE
EXISTING LOADING DOCK
F
IR
E L
A N
E
P A
R K
IN
G
N O
EXISTING RETAINING WALL
EXISTING RETAINING WALL
EXISTING FENCE
EXISTING CURB
EXISTING CURB
EXISTING STAIRS
NN
10'0 5'
W
G
B4
EDGE OF EXISTING CONCRETE PAVEMENT
#3 DOWEL BARS IN PLACE
PAVEMENT AND EPOXY NEW 24"
15" O.C. INTO EXISTING CONCRETE
DRILL ½" DIA. X 12" LONG HOLES,
EXISTING CONCRETE PAVEMENT
#3 BARS AT 15" O.C. BOTHWAYS
JOINT SEALANT
JOINT FILLER
3/4" NON EXTRUDING
COMPACTED TO 95% MAXIMUM DENSITY
6" TXDOT ITEM 247, TYPE A, GRADE 1-2 BASE
NEW CONCRETE PAVEMENT
½
/4
/8
½
RETAINING WALL, OR BUILDING FOUNDATION
EDGE OF CONCRETE LOADING DOCK, CONCRETE
SHEET
NUMBER
D ra w n b y
D e s ig n e d b y
S u b m it te d b y
S h e e t
S iz e
A N
S I
D
D a te
C o n tr a c t
N o
S o li c it a ti o n N o
F O
R T
W O
R T
H D
IS
T
R
IC
T
F O
R T
W O
R T
H
T E
X A
S
C h e c k e d b y
US Army Corps of
Engineers ®
A
R e v
M a rk
D e s c ri p ti o n
T ra c k in g
N o
A c ti o n
D a te
E N
G
IN
E E
R
IN
G
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
E N
G
IN
E E
R
IN
G B
R A
N C
H
PLOT DATE:
2 3 4 5 6 7 8 9 10
B
C
D
E
F
G
Fort Worth District
FILE PATH:
1/15/2019 12:39:43 PM
Enter Project Name
C H
IE
F
C
IV
IL
S E
C T
IO
N
B R
A N
T E
JE
N S
E N
P
.E
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
T
A Y
L O
R S
T
A P
R
IL
P N
T O
C L
A S
S R
O O
M F
A C
IL
IT
Y
R E
P U
R P
O S
E D
F A
C B
U
IL
D
IN
G
N O
R T
H F
O R
T H
O O
D T
E X
A S
B
F A
IR
B
F A
IR
D
B R
O W
N
P .E
C
O N
C R
E T
E P
A V
E M
E N
T D
E T
A
IL
C-501
CONCRETE PAVEMENT DETAILREF
N.T.S.
A
A-820
W
G
B4
1. ALL CMU SHALL BE 2-CELL BLOCK AND HAVE A SPECIFIED COMPRESSIVE STRENGTH f'm OF 2000psi ON NET AREA
AT 28 DAYS.
2. MORTAR - ASTM C 270, ASTM C 780, TYPE S, 2,000 psi MIN. AT 28 DAYS.
3. GROUT - ASTM C 476, ASTM C 1019, 2,000 psi MIN. AT 28 DAYS.
4. REINFORCEMENT - ASTM A615, GRADE 60.
5. CELLS WHICH CONTAIN REINFORCING STEEL SHALL BE FILLED SOLIDLY WITH 2000psi GROUT, INCLUDING BOND
BEAMS, LINTELS, AND PILASTERS.
6. VERTICAL CELLS TO BE FILLED SHALL HAVE VERTICAL ALIGNMENT SUFFICIENT TO MAINTAIN A CLEAR UNOBSTRUCTED CONTINUOUS VERTICAL CELL NOT LESS THAN 2 in x3 in IN PLAN DIMENSIONS.
7. FOUNDATION DOWELS SHALL EXTEND TO THE BOTTOM REINFORCING OF THE FOUNDATION AND 34 in INTO THE MASONRY WALL, UNLESS OTHERWISE DETAILED. LAPS OR SPLICES OF REINFORCING STEEL IN MASONRY SHALL BE 34 in. THERE SHALL BE A FOUNDATION DOWEL FOR EACH VERTICAL REINFORCING BAR, EXCEPT AS NOTED FOR
JAMB BARS IN NOTE 13.
8. VERTICAL WALL REINFORCING SHALL EXTEND CONTINUOUSLY FROM THE TOP OF FOUNDATION TO EMBED AT LEAST 6 in INTO BOND BEAM AT TOP OF WALL.
9. AN ADDITIONAL VERTICAL BAR WITH FOUNDATION DOWEL, SAME SIZE AND LENGTH AS THE NORMAL REINFORCING
BAR, SHALL BE PLACED:
A. ON EACH SIDE OF CONTROL JOINTS
B. AT INTERSECTION OF EXTERIOR WALLS
10. INTERIOR STRUCTURAL WALLS (SHEAR AND/OR BEARING) SHALL HAVE INTERMEDIATE BOND BEAMS LOCATED AT
THE SAME LEVELS AS EXTERIOR WALLS INTERMEDIATE BOND BEAMS.
11. BOND BEAM REINFORCING STEEL AND HORIZONTAL JOINT REINFORCEMENT FOR INTERIOR AND EXTERIOR WALLS SHALL BE CONTINUOUS THROUGHOUT, EXCEPT AS NOTED. LOCATION AND OF CONTROL JOINTS SHALL BE AS
SHOWN ON ARCHITECTURAL DRAWINGS.
A. AT CONTROL JOINTS, INTERMEDIATE BOND BEAM REINFORCEMENT SHALL BE DISCONTINUOUS.
REINFORCEMENT IN BOND BEAMS AT FLOOR AND ROOF DIAPHRAGM LEVELS SHALL BE CONTINUOUS.
B. AT ISOLATION JOINTS ALL BOND BEAM REINFORCING STEEL AND HORIZONTAL JOINT REINFORCEMENT
SHALL BE CUT.
12. LOCATION AND DETAILS OF CONTROL JOINTS SHALL BE AS DETAILED ON ARCHITECTURAL DRAWINGS AND AS INDICATED ON STRUCTURAL DRAWINGS. CMU CONTROL JOINTS SHALL BE LOCATED MINIMUM 24 in FROM EDGES
OF OPENINGS.
13. BARS AT TOP AND BOTTOM OF OPENINGS SHALL EXTEND A MINIMUM OF 40 BAR DIAMETERS OR 24 in, WHICHEVER IS LARGER, BEYOND CORNERS OR OPENINGS. VERTICAL JAMB BARS WILL BE THE SAME SIZE AND NUMBER (PER CELL) AS NORMAL VERTICAL REINFORCING. FOUNDATION DOWELS FOR JAMB BARS AROUND OPENINGS ARE
REQUIRED.
14. HORIZONTAL AND VERTICAL REINFORCING SHALL BE PROVIDED AS NOTED IN THE SPECIFICATIONS. WALL JOINT REINFORCING SHALL BE 9 GAGE LADDER TYPE SPACED AT 16 in ON CENTER VERTICALLY.
15. INTERMEDIATED BOND BEAMS WITH 2 - #5 BARS CONTINUOUS ARE REQUIRED AT THE SPACING NOTED IN THE CONTRACT DRAWINGS OR SPECIFICATIONS WITH A MAXIMUM VERTICAL SPACING OF 4'-0" ON CENTER.
16. LINTEL REINFORCEMENT SHALL BE SUPPORTED BY WIRE CHAIRS. PLACE REINFORCEMENT 3 in ABOVE BOTTOM OF LINTEL, UNLESS OTHERWISE NOTED. IN NO CASE SHALL BARS BE EXTENDED ACROSS CONTROL JOINTS.
17. MASONRY LINTELS SHALL HAVE A MINIMUM OF 24 in BEARING AT BOTH ENDS. STEEL LOOSE LINTELS SHALL HAVE MIN. 8 in BEARING EACH END, UNLESS OTHERWISE DETAILED. COORDINATE WITH ARCH FOR MASONRY CONTROL
JOINTS.
18. GROUTING: ALL CELLS WITH REINFORCING AND/OR ANCHORS SHALL BE FILLED WITH GROUT, INCLUDING BOND
BEAMS, LINTELS AND PILASTERS.
A. CONSOLIDATION: THE GROUT SHALL BE FULLY CONSOLIDATED.
B. GROUT SHALL BE PLACED IN CONTINUOUS POUR IN GROUT LIFTS NOT EXCEEDING 5 FT UNLESS
OTHERWISE NOTED.
C. HORIZONTAL CONSTRUCTION JOINTS : FORMED BY STOPPING THE GROUT POUR NOT LESS THAN 1/2 in BELOW THE TOP OF THE UPPERMOST UNITS GROUTED. HORIZONTAL REINFORCING SHALL BE FULLY
EMBEDDED IN GROUT. SHEET
NUMBER
D ra w n by
D es ig ne d by
Su bm itt ed b y:
Sh ee t S iz e
AN
SI
D
D at e:
C on tra ct
N o.
So lic ita tio n N o.
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
FO
R
T W
O R
TH
D
IS
TR
IC
T
TA
YL
O R
S T
FO
R
T W
O R
TH
, T
EX
AS
C he ck ed b y:
US Army Corps of Engineers ®
A
R ev
M ar k D es cr ip tio n Tr ac ki ng N o.
Ac tio n
D at e
EN
G
IN
EE
R
IN
G
C O
N
ST
R U
C
TI
O N
D
IV
IS
IO
N
EN
G
IN
EE
R
IN
G
B R
AN
C
H
PLOT DATE:
2 3 4 5 6 7 8 9 10
B
C
D
E
F
G
Fort Worth District
FILE PATH:
4/9/2021 3:59:18 PM
N O
R
TH
F O
R T
W O
R
TH
, T
EX
AS
R
EP
U
R
PO
SE
D
FA
C
B U
IL
D
IN
G
TO
C
LA
SS
R
O O
M F
AC
IL
IT
Y
PN
: 4
AP
R
IL
J.
R
O
BB
IN
S
J.
R
O
BB
IN
S
M
AT
TH
EW
P . V
AV
R
A, P
.E
C H
IE
F, S
TR
U C
TU
R
AL
S
EC
TI
O N
S-001
G
EN
ER
AL
S
TR
U C
TU
R
AL
N
O
TE
S
AN
D D
ET
AI
LS
I
N . A
LM
AS
R I
Enter Project Name
GENERAL REQUIREMENTS:
1. VERIFICATION: CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS, AND SITE CONDITIONS OF
EXISTING STRUCTURES BEFORE STARTING WORK. NOTIFY THE CONTRACTING OFFICER IN WRITING
IMMEDIATELY OF ANY DISCREPANCIES.
2. CODES: ALL MATERIALS AND WORK SHALL CONFORM TO THE REQUIREMENTS OF UFC 3-301-01 STRUCTURAL
ENGINEERING, WITH CHANGE 4, (1 NOV 2018).
3. VARIATIONS OR SUBSTITUTIONS: PROVIDE MANUFACTURER'S ICC REPORTS AND A LIST OF ALL PROPOSED SUBSTITUTIONS OR VARIATIONS TO THE CONTRACTING OFFICER FOR REVIEW AND APPROVAL BEFORE
FABRICATION.
4. PIPES, DUCTS, SLEEVES, CHASES, ETC.: SHALL NOT BE PLACED IN SLABS OR WALLS UNLESS SPECIFICALLY SHOWN OR NOTED NOR SHALL ANY STRUCTURAL MEMBER BE CUT FOR PIPES, DUCTS, ETC., UNLESS SPECIFICALLY SHOWN. THE CONTRACTOR SHALL OBTAIN WRITTEN CONSENT FROM THE CONTRACTING OFFICER BEFORE INSTALLATION OF ANY ADDITIONAL PIPES, DUCTS, SLEEVES, CHASES, ETC.
5. EXCAVATIONS: LOCATE AND PROTECT UNDERGROUND OR CONCEALED CONDUIT, PLUMBING OR OTHER
UTILITIES WHERE NEW WORK IS BEING PERFORMED.
6. CONSTRUCTION LOADS: MATERIALS SHALL BE EVENLY DISTRIBUTED IF PLACED ON FRAMED FLOORS OR ROOFS. LOADS SHALL NOT EXCEED THE ALLOWABLE LOADING FOR THE SUPPORTING MEMBERS AND THEIR
CONNECTIONS.
7. ITEMS THAT ARE SHOWN IN GRAYSCALE OR NOTED "EXIST." / "EXISTING" INDICATE EXISTING MATERIALS AND ITS RELATED ASSEMBLIES U.N.O. REFER TO ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS FOR EXISTING AND NEW NON- STRUCTURAL ITEMS WHICH REQUIRE SPECIAL PROVISIONS DURING THE
CONSTRUCTION OF STRUCTURAL MEMBERS.
8. REFER TO ARCHITECTURAL PLANS FOR FLOOR DEPRESSIONS, SLOPES, DRAINS, CURBS, PADS, EMBEDDED
ITEMS, NON-BEARING PARTITIONS, METAL STAIRS.
9. REFER TO MECHANICAL AND ELECTRICAL PLANS FOR LOCATIONS, TYPES AND SIZES OF SLEEVE AND
HANGERS FOR PIPES, DUCTS AND EQUIPMENT.
10. CONSTRUCTION METHODS AND PROJECT SAFETY: THE CONTRACT DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE AND DO NOT INDICATE METHODS, PROCEDURES OR SEQUENCE OF CONSTRUCTION. THE CONTRACTOR SHALL TAKE THE NECESSARY PRECAUTIONS TO MAINTAIN AND INSURE THE INTEGRITY OF THE STRUCTURE DURING CONSTRUCTION. THE CONTRACTOR SHALL DESIGN, CONSTRUCT AND MAINTAIN ALL SAFETY DEVICES, INCLUDING SHORING AND BRACING, AND BE SOLELY RESPONSIBLE FOR
CONFORMING TO ALL LOCAL, STATE AND FEDERAL SAFETY AND HEALTH STANDARDS, LAWS AND
REGULATIONS.
11. ANY DEVIATION FROM THE APPROVED SET OF STRUCTURAL DRAWINGS SHALL ONLY BE MADE AFTER WRITTEN APPROVAL BY THE CONTRACTING OFFICER. THE STRUCTURE SHALL NOT BE CONSIDERED TO BE STABLE DURING CONSTRUCTION UNTIL ALL ELEMENTS ARE IN PLACE AND CONNECTED. THE CONTRACTOR IS
RESPONSIBLE FOR ALL TEMPORARY CONSTRUCTION BRACING REQUIRED.
12. STRUCTURAL PLANS INDICATE ONLY THE APPROXIMATE LOCATION OF MECHANICAL, ELECTRICAL, AND OTHER EQUIPMENT, AS WELL AS THE RELATED AUXILIARY FRAMING NECESSARY TO SUPPORT SUCH EQUIPMENT FINAL POSITIONING OF THESE ITEMS IS DEPENDENT UPON THE EQUIPMENT PROVIDED BY THE CONTRACTOR.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING WORK BETWEEN SUBCONTRACTORS AND CRAFTS IN THIS REGARD, AND PROVIDING NECESSARY DIMENSIONS IN A TIMELY MANNER TO ALL PARTIES
INVOLVED.
13. ROOF AND FLOOR MEMBERS: PROVIDE TEMPORARY BRACING AS REQUIRED DURING THE ERECTION OF THE STRUCTURAL FRAME. BRACING MUST BE FULLY EFFECTIVE UNTIL ROOF AND FLOOR DEAD LOADS ARE IN
PLACE AND PERMANENT LATERAL LOAD RESISTING SYSTEMS ARE IN PLACE.
14. PROCEED WITH BACK FILLING OPERATIONS IN A SAFE AND UNIFORM MANNER. SEE SPECIFICATIONS FOR
REQUIREMENTS.
15. THE STRUCTURE SHALL NOT BE CONSIDERED TO BE STABLE DURING CONSTRUCTION UNTIL ALL ELEMENTS ARE IN PLACE AND CONNECTED. THE CONTRACTOR IS RESPONSIBLE FOR ALL TEMPORARY CONSTRUCTION
BRACING REQUIRED.
DESIGN CRITERIA:
1. GOVERNING BUILDING CODES:
1.1 DA PAMPHLET 385-64
1.2 DESR 6055.09
1.3 ACI 318-14
1.4 AISC STEEL MANUAL, 15TH EDITION
1.5 ASCE 7-16
1.6 AWS D1.1
1.7 IBC 2018, INTERNATIONAL BUILDING CODE.
1.8 UFC 3-301-01, STRUCTURAL ENGINEERING (CHANGE 4, 01 NOVEMBER 2018)
2. BUILDING OCCUPANCY CATEGORY: II
3. LIVE LOADS:
ROOF...................................................................................................20 psf (300 lbs CONCENTRATED)
OTHER LIVE LOADS NOT SHOWN SHALL BE IN ACCORDANCE WITH UFC 3-301-01 AND ASCE 7, MINIMUM.
4. NO CHANGES TO THE EXISTING PROTECTIVE CONSTRUCTION IS REQUIRED SINCE THERE IS NO CHANGE IN
CHARGE WEIGHTS OR OPERATIONS.
5. IN CASE OF DISCREPANCY BETWEEN CONTRACT DRAWINGS, CONTRACT SPECIFICATIONS, AND/OR
APPLICABLE CODES AND CRITERIA, THE MORE STRINGENT REQUIREMENTS SHALL BE APPLIED.
STEEL FRAMING NOTES:
1. STRUCTURAL STEEL MATERIAL PROPERTIES:
CHANNELS, ANGLES........................................................................ ASTM A36 (Fy = 36 ksi) PLATES AND BARS.............................................................. ............. ASTM A36 (Fy = 36 ksi) ANCHOR RODS.................................................................... ............. ASTM F 1554, GRADE 36 (Fy = 36 ksi)
2. SLIP CRITICAL CONNECTIONS SHALL BE PROVIDED AS INDICATED IN THE DRAWINGS. ALL OTHER
CONNECTIONS MAY BE BEARING TYPE.
2.1 DESIGN BEARING TYPE CONNECTIONS FOR FACTORED DESIGN FORCES/REACTIONS SHOWN ON THE DRAWINGS. IF FORCES/ REACTIONS ARE NOT PROVIDED ON THE DRAWINGS, THE FACTORED DESIGN REACTION SHALL BE HALF OF THE MAXIMUM TOTAL UNIFORM LOAD (LRFD) AS TABULATED
IN THE AISC MANUAL OF STEEL CONSTRUCTION.
2.2 WASHERS SHALL BE INSTALLED UNDER NUTS OF FASTENERS WHEN REQUIRED BY THE
SPECIFICATION FOR STRUCTURAL JOINTS.
3. WELDING SHALL CONFORM TO AWS D1.1 STRUCTURAL WELDING CODE.
3.1 WELDERS SHALL BE QUALIFIED FOR THE WORK PERFORMED IN ACCORDANCE WITH AWS D1.1.
3.2 WELD ELECTRODES SHALL BE E70.
4. SUBSTITUTION OF DRILLED OR ADHESIVE ANCHORS FOR EMBEDDED ANCHORS SHOWN ON THE DRAWINGS
WILL NOT BE PERMITTED.
5. INSTALLATION OF EXPANSION, ADHESIVE, OR SCREW ANCHORS SHALL BE IN ACCORDANCE WITH THE ICC REPORT FOR THAT PARTICULAR TYPE OF ANCHOR. PROVIDE ICC REPORT FOR THE ANCHOR SYSTEM USED.
6. STRUCTURAL STEEL EXPOSED TO WEATHER SHALL BE HOT-DIP GALVANIZED, G-90.
1. PROVIDE SPECIAL INSPECTIONS IN ACCORDANCE WITH CHAPTER 17, SECTION 1704 OF THE
IBC FOR THE FOLLOWING AREAS:
1.1 STEEL CONSTRUCTION SECTION 1705.2
1.2 CONCRETE CONSTRUCTION SECTION 1705.3
1.4 PLUMBING, MECHANICAL, AND ELECTRICAL COMPONENTS SECTION 1705.12.6
STATEMENT OF SPECIAL INSPECTIONS:
DEMOLITION NOTES:
1. PROVIDE ADEQUATE SHORING, BRACING AND OTHER TEMPORARY SUPPORT DURING DEMOLITION.
2. UNTIL PROPERLY SHORED, DO NOT CUT EXISTING STRUCTURAL MEMBER IN A MANNER RESULTING IN A REDUCTION OF LOAD-CARRYING CAPACITY. DO NOT EXCEED THE CAPACITY OF THE EXISTING STRUCTURE
WITH SUPERIMPOSED LOADS.
3. IN GENERAL, SELECTIVE STRUCTURAL DEMOLITION IS TO BE PERFORMED WITH PHYSICAL CUTTING ACTION (I.E. SAWING AND GRINDING INSTEAD OF HAMMERING AND CHOPPING). DO NOT USE JACKHAMMERS ON
STRUCTURALLY SUPPORTED MEMBERS.
4. CONTRACTOR SHALL VERIFY THAT EXISTING CONSTRUCTION CORRESPONDS TO THAT SHOWN ON THE
DRAWINGS. DISCREPANCIES SHALL BE IMMEDIATELY REPORT TO CONTRACTING OFFICER.
5. REMOVE CONCRETE STAIRS AT LOADING DOCK.
CAST-IN-PLACE CONCRETE NOTES:
1. MATERIAL PROPERTIES:
BARS...................................................................................................... ASTM A615, GRADE 60
2. THE CONCRETE STRENGTHS INDICATED ARE THE MINIMUM COMPRESSIVE STRENGTHS AT 28 DAYS.
SLAB ON GRADE ................................................................................. 4,000 psi
3. CONCRETE SHALL BE PROPORTIONED SUCH THAT 7 DAY STRENGTHS ARE A MINIMUM OF 70% OF THE SPECIFIED 28 DAY STRENGTH FOR ANY CONCRETE CONSTRUCTION REQUIRING SHORING, BRACING, OR TO RECEIVE
CONSTRUCTION LOADS.
4. ADMIXTURES SHALL NOT CONTAIN CALCIUM CHLORIDE.
5. SHOP DRAWINGS, FABRICATION, AND PLACEMENT FOR REINFORCING SHALL CONFORM TO ACI 318.
6. CONCRETE REINFORCEMENT COVER SHALL BE AS SHOWN IN THE TABLE ON SHEET S-002 UNLESS OTHERWISE
NOTED.
7. SPLICE AND EMBEDMENT LENGTHS SHALL BE AS SHOWN IN THE TABLE ON SHEET S-002 UNLESS OTHERWISE
NOTED.
8. ADHESIVE FOR DOWELS INTO EXISTING CONCRETE SHALL BE HILTI HIT HY200, EPCON SYSTEM CERAMIC EPOXY, POWER-FAST EPOXY, SIMPSON ACRYLIC-TIE, OR EQUALLY APPROVED BY THE CONTRACTING OFFICER PRIOR TO USE. MINIMUM EMBEDMENT SHALL BE 12 TIMES THE BAR DIAMETER, BUT MUST ALSO MEET THE PRODUCT MANUFACTURERS RECOMMENDATIONS, UNLESS OTHERWISE NOTED. INSTALLATION OF EXPANSION, ADHESIVE, OR
SCREW ANCHORS SHALL BE IN ACCORDANCE WITH THE ICC
REPORT FOR THAT PARTICULAR TYPE OF ANCHOR. PROVIDE ICC REPORT FOR THE ANCHOR SYSTEM USED.
9. FOR SPECIAL FINISHES, REFER TO ARCHITECTURAL DRAWINGS FOR MOLDS, GROOVES, ORNAMENTS, CLIPS, OR GROUNDS REQUIRED TO BE ENCASED IN CONCRETE AND FOR LOCATION OF FLOOR FINISHES AND SLAB
DEPRESSIONS.
10. HONEY-COMBING, SPALLS, CRACKS, ETC. SHALL BE REPAIRED. EXTENT OF THE DEFECTIVE AREA SHALL BE DETERMINED BY CONTRACTOR PER STANDARD QC PLAN. DO NOT REPAIR ANY CRACK THAT IS LESS THAN 0.005in
AT ITS WIDEST POINT.
REINFORCED HOLLOW CMU NOTES:
W
G
B4
EM
BE
D M
EN
T
1/
2" M
IN
IM
U M
(T
YP
4"
M
IN
#4@12" E.W.
SLAB ON
GRADE; REINF.
OMITTED FOR
CLARITY
DRILL & GROUT #
4 DOWELS @ 12"
(TYP 4 SIDE)
3/4" CHAMFER
(TYP)
SIZE PER EQUIP MANUF
TYP
6" MIN
EXISTING
CONCRETE SLAB
SEE PLANS 1'-0" MIN.
1" DEEP MIN. SAW CUT
REPLACE WITH
COMPACTED
NON-EXPANSIVE
FILL AS REQ'D
SEE FOUNDATION PLAN FOR
PATCH REINFORCING
REQUIRMENTS EPOXY DOWEL
EACH BAR MIN. 6" INTO EXISTING
SLAB.
NEW CONCRETE
PATCH
6" CAPILLARY
WATER BARRIER
EXISTING VAPOR
BARRIER
1/
2" C
LR
PROVIDE #4 BAR
MIN. 3" FROM PATCH
EDGE, TYP.
EXISTING SLAB
CONCRETE BELOW TOP
1" SHALL BE
ROUGHENED TO 1/4"
AMPLITUDE.
EXCAVATION
LIMITS
BAR
SIZE
BAR
DIAMETER
(in.)
CLASS B LAP (in.)
TOP BAR OTHER BARS
CASE 1 CASE 2
TOP BAR OTHER BARS
CASE 1 CASE 2CASE 1 CASE 2 CASE 1 CASE 2
22 32 17 25 28 42 22 32 29 43 22 33 37 56 29 43
0.375 0.500 0.625 0.750 0.875 1.000 1.128 1.270
1.410 101
196 101
DEVELOPMENT AND
CLASS A LAP (in.)
1. TABLE A PRESENTS TENSION DEVELOPMENT LENGTHS AND TENSION LAP SPLICE LENGTHS BASED ON ACI318, SECTION 12.2.2.
2. CLASS A LAP LENGTHS APPLY WHEN BAR LAPS ARE STAGGERED TO LAP HALF OR FEWER BARS AT THE SAME LOCATIONS OR WHEN BARS ARE LAPPED AT A LOCATION WHERE THE REINFORCEMENT AREA PROVIDED IS AT LEAST TWICE THAT REQUIRED.
3. CLASS B LAP LENGTHS APPLY WHEN MORE THAN HALF THE BARS ARE SPLICED AT A LOCATION OF MAXIMUM STRESS IN THE BARS.
4. CASE 1 LENGTHS APPLY TO BEAMS AND COLUMNS WITH CONCRETE COVER EQUAL TO OR GREATER THAN THE BAR DIAMETER, CLEAR BAR SPACING EQUAL TO OR GREATER THAN THE BAR DIAMETER AND WITH STIRRUPS OR TIES NOT LESS THAN THE CODE MINIMUM THROUGH OUT THE LENGTH IN THE TABLE; AND FOR OTHER ELEMENTS WITH CONCRETE COVER EQUAL TO OR GREATER THAN TWO TIMES THE BAR DIAMETER AND CLEAR SPACING NOT LESS THAN TWO TIMES BAR DIAMETER.
5. CASE 2 LENGTHS APPLY TO BEAMS AND COLUMNS WITH CONCRETE COVER LESS THAN THE BAR DIAMETER, OR CLEAR BAR SPACING LESS THAN THE BAR DIAMETER; AND FOR OTHER ELEMENTS WITH CONCRETE COVER LESS THAN THE BAR DIAMETER
OR CLEAR BAR SPACING LESS THAN TWO TIMES THE BAR DIAMETER.
6. TOP BARS ARE HORIZONTAL REINFORCEMENT PLACED SO THAT MORE THAN 12" OF CONCRETE IS CAST BELOW THE REINFORCEMENT.
7. MULTIPLY LENGTHS SHOWN BY 0.87 FOR 4,000 psi CONCRETE.
8. MULTIPLY LENGTHS SHOWN BY 1.3 FOR LIGHTWEIGHT AGGREGATE CONCRETE.
9. MULTIPLY LENGTHS SHOWN BY 1.3 FOR EPOXY-COATED BARS.
fy = 60,000 psi, f'c = 3,000 psi (see notes)
TABLE A - REINFORCEMENT TENSION LAPS AND DEVELOPMENT
#6 x 8" SMOOTH DOWELS @ 12"
O.C. EPOXY EMBED 6" INTO
EXISTING CONCRETE. EXTEND
DOWEL 12" INTO NEW
CONCRETE. GREASE DOWEL IN
NEW CONCRETE SLAB. PLACE
DOWEL MIN. 2 1/2" BELOW
SURFACE.
SEE ARCH. DRAWING
1/4" DROP MAX.
1/2" P.E.J.
5" SLAB w/ #4's @
12" OCEW 2" CLEAR
FROM TOP
COMPACTED NON-
EXPANSIVE FILL
#4 CONT.
10"
#4 SLOPE 1%
1' -0
" M
IN
EXISTING
FOUNDATION
6"
SEE NOTE 1
NOTES:
1. DRILL 3/4" HOLES AT CORNERS OF PROPOSED OPENING.
2. BOUNDARY OF PROPSED OPEING SHALL BE SAW CUT TO
DRILLED HOLES. "DO NOT OVER CUT."
3. MAINTAIN A MINIMUM OF 4'-0" CLEAR BETWEEN EDGE OF
OPENING.
SEE NOTE 2
SEE NOTE 3
5"
CORE DRILL INTO GRADE
BEAM AS REQUIRED FOR
PLUMBING. CONTRACTOR
SHALL LOCATE AND AVOID
CUTTING EXISTING GRADE
BEAM STIRRUPS AND
HORIZONTAL STEEL.
COORDINATE PLUMBING
LOCATIONS WITH PLUMBING
PLANS.
EXISTING GRADE BEAM
NOTE:
1. CONTRACTOR SHALL VERIFY EXISTING REINFORCING LOCATIONS
BEFORE PENETRATING THE BEAM. CONTRACTOR SHALL NOT CUT ANY
EXISTING REINFORCING WITHIN THE BEAM. BEAM SHALL BE DEEPENED
AS NECESSARY TO MEET THIS REQUIREMENTS.
2. COORD. w/ MECH DWGS FOR LOCATION AND SIZE OF CONDUITS.
1' - 0"
3'
- 0
EXISTING CONCRETE SLAB
M
AX
6"
DESCRIPTION SINGLE LAYER
TWO LAYERS
REMARKS
SLAB
BEAMS
OTHER
ON GRADE
OF RIBBED MATS
SUPPORTED
ON CARTON FORMS
ON CONCRETE
ON METAL DECK
FORMED GRADE BEAMS
IN RIBBED MATS
ABOVE GRADE
JOISTS
SPOT FOOTINGS
COLUMNS AND PLINTHS
DESCRIPTION
1 1/2 " FROM TOP
TOP BOTTOM
CENTERED
CENTERED
3/4"
3/4"
3/4"
3"
3/4"
1 1/2"
SIDE TOP BOTTOM
1 1/2"
1 1/2"
1 1/2" 1 1/2"
1 1/2" 1 1/2"
1 1/2"
2"
3"
3/4" 3/4"
2"
3"
1 1/2"
3/4"
3"
1 1/2" WHEN EXPOSED TO
WEATHER
T/4 (1 1/2"<T/4 <2 1/2 ")
T = SLAB THICKNESS2
3 2" FOR #6 AND LARGER OR
EXPOSED TO EARTH
4 3" IF CAST ON EARTH
2" FOR #6 AND LARGER WHEN
EXPOSED TO WEATHER
5 5
1 1
NOTE: UNLESS OTHERWISE NOTED ON DRAWINGS, CONCRETE COVER OVER PRIMARY REINFORCEMENT, TIES, STIRRUPS, AND SPIRALS SHALL COMPLY WITH LISTED VALUES. COVER SHALL COMPLY WITH REQUIREMENTS OF ACI 318 FOR ELEMENTS NOT DESCRIBED.
3/4" FROM BOTTOM
1 1/2 " FROM BOTTOM
WALLS INTERIOR FACES
EXTERIOR EXPOSED FACES
CENTERED
CENTERED
3/4"
1 1/2"
TABLE B
CONCRETE COVER (in) FOR CAST-IN-PLACE
NON-PRESTRESSED CONCRETE FOR BUILDINGS
1 1
SHEET
NUMBER
D ra w n by
D es ig ne d by
Su bm itt ed b y:
Sh ee t S iz e
AN
SI
D
D at e:
C on tra ct
N o.
So lic ita tio n N o.
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
FO
R
T W
O R
TH
D
IS
TR
IC
T
TA
YL
O R
S T
FO
R
T W
O R
TH
, T
EX
AS
C he ck ed b y:
US Army Corps of Engineers ®
A
R ev
M ar k D es cr ip tio n Tr ac ki ng N o.
Ac tio n
D at e
EN
G
IN
EE
R
IN
G
C O
N
ST
R U
C
TI
O N
D
IV
IS
IO
N
EN
G
IN
EE
R
IN
G
B R
AN
C
H
PLOT DATE:
2 3 4 5 6 7 8 9 10
B
C
D
E
F
G
Fort Worth District
FILE PATH:
4/9/2021 3:59:21 PM
N O
R
TH
F O
R T
W O
R
TH
, T
EX
AS
R
EP
U
R
PO
SE
D
FA
C
B U
IL
D
IN
G
TO
C
LA
SS
R
O O
M F
AC
IL
IT
Y
PN
: 4
AP
R
IL
J.
R
O
BB
IN
S
J.
R
O
BB
IN
S
M
AT
TH
EW
P . V
AV
R
A, P
.E
C H
IE
F, S
TR
U C
TU
R
AL
S
EC
TI
O N
S-002
G
EN
ER
AL
S
TR
UC
TU
RA
L
NO
TE
S
AN
D
DE
TA
IL
S
II
N . A
LM
AS
R I
Enter Project Name
NTS1
EQUIPMENT PAD ON SLAB-ON-GRADE
DETAIL
NTS2
EXISTING SLAB REMOVAL &
REPLACEMENT FOR NEW PLUMBING
DETAIL
NTS4 TYP. STOOP SECTION
NTS5 CUT OPENING DETAIL
1 1/2" = 1'-0"3
TYPICAL EXISTING GRADE BEAM
PENETRATION DETAIL
W
G
B4
NOTES:
1. MINIMUM CLEARANCE OF 1" OR LIVE LOAD DEFLECTION, WHICHEVER IS GREATER.
WHEN STUDS EXTEND TO DECK OR FLOOR ABOVE, PROVIDE THE REQUIRED MINIMUM
CLEARANCE WITH LATERAL SUPPORT AT BOTTOM CHORD.
2. THIS LATERAL SUPPORT DETAIL IS FOR WHEN CROSS WALL SUPPORT SPACING
EXCEEDS 8'-0".
PERPENDICULAR TO TRUSSES
PARALLEL TO TRUSSES
DECK, ROOF OR FLOOR
FIRE STOPPING
MATERIAL AS REQUIRED
CONT. TRACK
L2 1/2x2x3/16 (LLV)x6" @
6'-0" O.C. WELD TO 3/16"
ANGLE
TRUSSES BOTTOM
FLANGE (TYP)
L2x2x3/16 WELD TO BEAM OR
ATTACHED TO BOTTOM FLANGE
@ 6'-0" O.C.
CONT. TRACK
FIRE STOPPING MATERIAL
AS REQUIRED
ROOF DECK
TRUSS BOTTOM FLANGE
SE
E
N O
TE
SE
E
N O
TE
SE
E
N O
TE
SE
E
N O
TE L2 1/2x2x3/16 (LLV)x6" @
6'-0" O.C. WELD TO BEAM BOTTOM
FLANGE
4"
1' - 8"
1/
4"
1' - 10"
FINISHED FLOOR
EXISTING FLOOR DRAIN
3"
EXISTING TRENCH
DRAIN WITH GRATING
REMOVE EXISTING GRATING, CAP
EXISTING FLOOR DRAIN (REFER TO MECH.
FOR EXISTING FLOOR DRAIN LOCATIONS).
FILL IN 5,000psi GROUT, LEVEL WITH
EXISTING SLAB
NOTE:
CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS.
GYPSUM WALLBOARD CEILING
4'-0"
5'-0"
6'-0"
7'-0"
8'-0"
MAXIMUM
TRUSS
SPACING
DESIGN NOTE: SUSPENDED CEILING IS SHOWN.
WHERE SUSPENDED CEILING IS NOT REQUIRED, AT
EACH FURRING (CHANNELS OR STUDS AS
REQUIRED BY SPAN) DIRECTLY TO BOTTOM CHORD
OF TRUSS.
FURRING @ 16" OC
GYPSUM BOARD
CEILING
DECK
1-1/2" RUNNER
CHANNEL (TYP)
8 GA. HANGING
WIRES
4'-0"
3'-6"
3'-0"
3'-0"
2'-6"
HANGER
SPACING
24 GA 7/8"
24 GA 1-5/8"
24 GA 2-1/2"
24 GA 2-1/2"
24 GA 3-5/8"
FURRING
SIZE
ACOUSTICAL TILE CEILING
DECK
T BAR GRID SYSTEM
12 GA HANGING WIRES @
4'-0" OCEW MAX
DECK
T BAR GRID SYSTEM
12 GA. HANGING WIRES
@ 4'-0" OCEW MAX
AUXILIARY FURRING @ 4'-0" OC SIZE AS REQUIRED
BY TRUSS SPACING, BOLTED OR 18 GA TIE WIRE
ATTACHED TO TRUSS
FURRING IS ATTACHED RUNNER
BY USING 18 GA. TIE WIRE
TRUSS MAX
SPACING
4'-0" O.C.
SHEET
NUMBER
D ra w n by
D es ig ne d by
Su bm itt ed b y:
Sh ee t S iz e
AN
SI
D
D at e:
C on tra ct
N o.
So lic ita tio n N o.
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
FO
R
T W
O R
TH
D
IS
TR
IC
T
TA
YL
O R
S T
FO
R
T W
O R
TH
, T
EX
AS
C he ck ed b y:
US Army Corps of Engineers ®
A
R ev
M ar k D es cr ip tio n Tr ac ki ng N o.
Ac tio n
D at e
EN
G
IN
EE
R
IN
G
C O
N
ST
R U
C
TI
O N
D
IV
IS
IO
N
EN
G
IN
EE
R
IN
G
B R
AN
C
H
PLOT DATE:
2 3 4 5 6 7 8 9 10
B
C
D
E
F
G
Fort Worth District
FILE PATH:
4/21/2021 1:25:33 PM
N O
R
TH
F O
R T
W O
R
TH
, T
EX
AS
R
EP
U
R
PO
SE
D
FA
C
B U
IL
D
IN
G
TO
C
LA
SS
R
O O
M F
AC
IL
IT
Y
PN
: 4
AP
R
IL
J.
R
O
BB
IN
S
J.
R
O
BB
IN
S
M
AT
TH
EW
P . V
AV
R
A, P
.E
C H
IE
F, S
TR
U C
TU
R
AL
S
EC
TI
O N
S-003
G
EN
ER
AL
S
TR
U C
TU
R
AL
N
O
TE
S
AN
D D
ET
AI
LS
II
I N
. A
LM
AS
R
I
Enter Project Name
NTS1
METAL STUD PARTITION LATERAL
SUPPORT
NTS3 GROUT FILL IN EXISTING DRAIN DETAIL
NTS2 SUSPENDED CEILING DETAILS
W
G
B4
1 2 4 5 6 7 8 9 10 11
B
C
D
E
8"
2'
0"
10' - 6" 2'
0"
1' - 6"
2' - 0"
2'
0" 2'
0"
8" 13' - 1" 1' - 11" 13' - 3" 20' - 0" 22' - 6" 17' - 0" 17' - 0" 16' - 11"
1' - 6"
1' - 6"
6' - 6"
2' - 6"
8' - 0"
2'
2"
8'
2" 2' - 6"
2'
6"
7'
8"
8' - 10" 2' - 6"
2'
6"
2'
4"
10' - 7"
2' - 0"
2' - 0"
2'
0"
4' - 3"
1' - 2"
3'
0" 3' - 3"
2' - 9"
1' - 2"
3'
0"
9'
6"
2'
2"
9' - 3"
6' - 8"
6' - 2"
1. CONTRACTOR TO INSPECT EXISTING CONDITIONS BEFORE
DEMOLITION AND NOTIFY CONTRACTING OFFICER BEFORE
PROCEEDING WORK.
2. DO NOT DEMOLISH CONCRETE OVER FOUNDATION BEAMS.
COORDINATE EXACT LOCATIONS AND EXTEND OF REQ'D SLAB
REMOVAL WITH ALL APPLICABLE TRADES.
3. CONTRACTOR TO VERIFY DIMENSIONS OF EXISTING
FOUNDATION BEAMS WITH IN THE DEMO AREAS.
4. DO NOT CUT THROUGH EXISTING FOUNDATION BEAMS
THROUGHOUT THE BUILDING.
FOUNDATION DEMOLITION NOTES
SAW CUT AND DEMOLISH EXISTING SLAB-ON-GRADE
SHOWN IN THE DRAWING.
FOUNDATION DEMOLITION LEGEND
SHEET
NUMBER
D ra w n by
D es ig ne d by
Su bm itt ed b y:
Sh ee t S iz e
AN
SI
D
D at e:
C on tra ct
N o.
So lic ita tio n N o.
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
FO
R
T W
O R
TH
D
IS
TR
IC
T
TA
YL
O R
S T
FO
R
T W
O R
TH
, T
EX
AS
C he ck ed b y:
US Army Corps of Engineers ®
A
R ev
M ar k D es cr ip tio n Tr ac ki ng N o.
Ac tio n
D at e
EN
G
IN
EE
R
IN
G
C O
N
ST
R U
C
TI
O N
D
IV
IS
IO
N
EN
G
IN
EE
R
IN
G
B R
AN
C
H
PLOT DATE:
2 3 4 5 6 7 8 9 10
B
C
D
E
F
G
Fort Worth District
FILE PATH:
PLAN NORTH
4/9/2021 3:59:36 PM
N O
R
TH
F O
R T
W O
R
TH
, T
EX
AS
R
EP
U
R
PO
SE
D
FA
C
B U
IL
D
IN
G
TO
C
LA
SS
R
O O
M F
AC
IL
IT
Y
PN
: 4
AP
R
IL
J.
R
O
BB
IN
S
J.
R
O
BB
IN
S
M
AT
TH
EW
P . V
AV
R
A, P
.E
C H
IE
F, S
TR
U C
TU
R
AL
S
EC
TI
O N
SD-100
FO
UN
DA
TI
O N
DE
M
O
LI
TA
TI
O N
PL
AN
N . A
LM
AS
R I
Enter Project Name
1/8" = 1'-0"1 FOUNDATION DEMOLITATION PLAN
W
G
B4
1 2 4 5 6 7 8 9 10 11
B
C
D
E
8"
2'
0"
10' - 6"
2'
0"
1' - 6"
8" 13' - 1" 1' - 11" 13' - 3" 20' - 0" 22' - 6" 17' - 0" 17' - 0" 16' - 11"
1' - 6"
1' - 6"
6' - 6"
2' - 6"
8' - 0"
2'
2"
8'
2"
2' - 6"
2'
6"
8' - 10" 2' - 6"
2'
6"
2'
0" 4' - 3"
3' - 4"
1' - 2"
2' - 9"
1' - 2"
3'
0" 3'
0"
2' - 0"
2'
0" 2'
0"
123' - 0"
1' - 3" 1' - 6"
9'
6"
7' - 8" 2' - 0"
7' - 2"
2'
4"
1. REFER TO ARCH AND PLUMBING DRAWINGS FOR NEW
FLOOR DRAIN LOCATIONS.
2. CAP EXISTING FLOOR DRAIN, REFER TO MECH. DWGS.
PLACE 5,000 psi GROUT IN FILL WITH EXISTING FLOOR
DRAINS/TRENCH DRAINS, THEN LEVEL THE CONCRETE
FLOOR SEE DETAIL 3/S-003.
3. FOR DIFFERING SITE CONDITIONS, THE CONTRACTOR
SHALL NOT MAKE ANY REVISIONS TO THE BUILDING UNTIL
APPROVED BY THE CONTRACTING OFFICER.
4. ALL DIMENSION SHOWN SHALL BE VERIFIED BY THE
CONTRACTOR. COORDINATE WITH ARCH., MECH. AND
PLUMBING DRAWINGS FOR EXISTING AND NEW
CONDITIONS.
5. THE UPPER 6 INCHES OF EXISTING FILL EXPOSED AFTER
FLOOR SLAB DEMOLITION OPERATIONS SHALL BE
SCARIFIED, MOISTENED, MANIPULATED, AND
RECOMPACTED TO AT LEAST 95 PERCENT OF LABORATORY
MAXIMUM DENSITY.
6. CONTRACTOR SHALL NOT CUT THROUGH EXISTING
FOUNDATION GRADEBEAMS.
7. CONCRETE SLAB SHALL BE REINFORCED WITH #4 @ 8" O.C.
EACH WAY, 1 1/2" FROM TOP OF SLAB. SLAB SHALL BE OVER
VAPOR BARRIER AND 6" CAPILLARY WATER BARRIER ON
NON-EXPANSIVE, COMPACTED FILL.
FOUNDATION NOTES:
EDGE OF THE NEW 5" S.O.G. w/ #4 @ 8" O.C.
EACH WAY, 1 1/2" FROM TOP OF SLAB.
FOUNDATION LEGEND:
SHEET
NUMBER
D ra w n by
D es ig ne d by
Su bm itt ed b y:
Sh ee t S iz e
AN
SI
D
D at e:
C on tra ct
N o.
So lic ita tio n N o.
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
FO
R
T W
O R
TH
D
IS
TR
IC
T
TA
YL
O R
S T
FO
R
T W
O R
TH
, T
EX
AS
C he ck ed b y:
US Army Corps of Engineers ®
A
R ev
M ar k D es cr ip tio n Tr ac ki ng N o.
Ac tio n
D at e
EN
G
IN
EE
R
IN
G
C O
N
ST
R U
C
TI
O N
D
IV
IS
IO
N
EN
G
IN
EE
R
IN
G
B R
AN
C
H
PLOT DATE:
2 3 4 5 6 7 8 9 10
B
C
D
E
F
G
Fort Worth District
FILE PATH:
PLAN NORTH
4/9/2021 3:59:27 PM
N O
R
TH
F O
R T
W O
R
TH
, T
EX
AS
R
EP
U
R
PO
SE
D
FA
C
B U
IL
D
IN
G
TO
C
LA
SS
R
O O
M F
AC
IL
IT
Y
PN
: 4
AP
R
IL
J.
R
O
BB
IN
S
J.
R
O
BB
IN
S
M
AT
TH
EW
P . V
AV
R
A, P
.E
C H
IE
F, S
TR
U C
TU
R
AL
S
EC
TI
O N
S-101
FO
U
N D
AT
IO
N P
LA
N
N . A
LM
AS
R I
Enter Project Name
1/8" = 1'-0"1 FOUNDATION PLAN
8'4' 16'0
W
G
B4
WINDOW
OPENING
NOTES:
1. TEMPORARILY SUPPORT EXISTING WALL PRIOR TO DEMOLITION.
2. REFER TO ARCH. DWG FOR OPENING LOCATIONS.
STEEL LINTEL;
L8X8X1/2
REMOVE EXISTING
MASONRY WALL
AS REQUIRED TO
INSTALL WINDOW
T.O. SLAB
4' - 0"
MIN.
1' - 0"
MIN.
1' - 0" 4'
8"
A
A
GROUT SIDES TO
PROVIDE SMOOTH
SURFACE FOR
INSTALLATION
OF WINDOW
JAMBS
ELEVATION VIEW
DOOR
OPENING
NOTES:
1. TEMPORARILY SUPPORT EXISTING WALL PRIOR TO DEMOLITION.
2. REFER TO ARCH. DWG FOR OPENING LOCATIONS.
STEEL LOOSE LINTEL;
L8X8X1/2 LLV
REMOVE EXISTING
MASONRY WALL
AS REQUIRED TO
INSTALL DOOR
T.O. SLAB
3' - 4"
MIN.
1' - 4" 1' - 4"
7'
4"
A
A
GROUT SIDES TO
PROVIDE SMOOTH
SURFACE FOR
INSTALLATION
OF DOOR JAMBS
ELEVATION VIEW
1/4
TYP.
STEEL JAMB;
L8x8x1/2, FASTEN TO MASONRY WALL w/ 3/4"
DIA. MASONRY ANCHOR
BOLTS (BASIS OF
DESIGN: HILTI HIT HY
270) AT 16" O.C. w/ 6"
EMBEDMENT, (TYP.)
C C
DOOR OPENING
NOTES:
1. TEMPORARILY SUPPORT EXISTING WALL PRIOR TO DEMOLITION.
2. REFER TO ARCH. DWG FOR OPENING LOCATIONS.
STEEL LOOSE LINTEL;
(2) L6X4X1/2 LLV
REMOVE EXISTING
MASONRY WALL
AS REQUIRED TO
INSTALL DOOR
T.O. SLAB
6' - 4"
MIN.
1' - 8" 1' - 8"
7'
4"
B
B
GROUT SIDES TO
PROVIDE SMOOTH
SURFACE FOR
INSTALLATION
OF DOOR JAMBS
CLOSURE PLATE;
PL1/4, (TYP.)
ELEVATION VIEW
1/4
TYP.
D D STEEL LOOSE
JAMB (2) L6X4X1/2
LLV (TYP.)
OPENING
NOTES:
1. TEMPORARILY SUPPORT EXISTING WALL PRIOR TO DEMOLITION.
2. REFER TO ARCH. DWG FOR OPENING LOCATIONS.
STEEL LOOSE LINTEL;
(2) L6X4X1/2 LLV
REMOVE EXISTING
MASONRY WALL
AS REQUIRED TO
INSTALL DOOR
T.O. SLAB
3' - 4"
MIN.
1' - 4"
MIN.
1' - 4"
7'
4"
B
B
GROUT SIDES TO
PROVIDE SMOOTH
SURFACE FOR
INSTALLATION
OF DOOR JAMBS
CLOSURE PLATE;
PL1/4 (TYP.)
ELEVATION VIEW
D D
1/4
TYP.
SECTION A
L8X8X1/2, FASTEN TO
MASONRY WALL w/ 3/4"
DIA. MASONRY
ANCHOR BOLTS (BASIS
OF DESIGN: HILTI HIT
HY 270) AT 16" O.C. w/
6" EMBEDMENT.
INTERIOR
FACE
4"
SECTION B
L6X4X1/2 LLV
5" WIDE 1/4" THICK PLATE
3/16 2 @ 8"
LADDER TYPE
HORIZONTAL JOINT
REINFORCING @ 16" O.C.
8" CMU WALL REINFORCED
WITH #5 @ 16". ALL
REINFORCED CELLS SHALL
BE FULLY GROUTED.
FI
EL
D
VE
R I
FY
3'
- 0
EXISTING
FUNDATION AND
SLAB
4"
8" BOND BEAM
WITH 1 #5 T&B TYP.
1' - 0"
5" 1'
0"
EPOXY DOWEL BAR INTO EXISTING
CONCRETE SLAB MIN. 12" (BASIS OF
DESIGN: HILTI HY 200). MATCH WALL
REINFORCING SIZE AND SPACING.
1'
0"
NOTES:
1. REFER TO ARCH. DWG FOR FILL IN OPENING LOCATIONS.
SECTION D
L6X4X1/2 LLV
5" WIDE 1/4" THICK PLATE
3/16 2 @ 8"
SECTION C
L8X8X1/2, FASTEN TO
MASONRY WALL w/ 3/4"
DIA. MASONRY
ANCHOR BOLTS (BASIS
OF DESIGN: HILTI HIT
HY 270) AT 16" O.C. w/
6" EMBEDMENT.
INTERIOR
FACE
4"
DOOR
OPENING
NOTES:
1. TEMPORARILY SUPPORT EXISTING WALL PRIOR TO DEMOLITION.
2. REFER TO ARCH. DWG FOR OPENING LOCATIONS.
STEEL LOOSE LINTEL;
L8X8X1/2 LLV
REMOVE EXISTING
MASONRY WALL
AS REQUIRED TO
INSTALL DOOR
T.O. SLAB
4' - 0"
MIN.
1' - 4" 1' - 4"
7'
4"
A
A
GROUT SIDES TO
PROVIDE SMOOTH
SURFACE FOR
INSTALLATION
OF DOOR JAMBS
ELEVATION VIEW
1/4
TYP.
STEEL JAMB;
L8x8x1/2, FASTEN TO MASONRY WALL w/ 3/4"
DIA. MASONRY ANCHOR
BOLTS (BASIS OF
DESIGN: HILTI HIT HY
270) AT 16" O.C. w/ 6"
EMBEDMENT, (TYP.)
C C
SHEET
NUMBER
D ra w n by
D es ig ne d by
Su bm itt ed b y:
Sh ee t S iz e
AN
SI
D
D at e:
C on tra ct
N o.
So lic ita tio n N o.
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
FO
R
T W
O R
TH
D
IS
TR
IC
T
TA
YL
O R
S T
FO
R
T W
O R
TH
, T
EX
AS
C he ck ed b y:
US Army Corps of Engineers ®
A
R ev
M ar k D es cr ip tio n Tr ac ki ng N o.
Ac tio n
D at e
EN
G
IN
EE
R
IN
G
C O
N
ST
R U
C
TI
O N
D
IV
IS
IO
N
EN
G
IN
EE
R
IN
G
B R
AN
C
H
PLOT DATE:
2 3 4 5 6 7 8 9 10
B
C
D
E
F
G
Fort Worth District
FILE PATH:
4/9/2021 3:59:30 PM
N O
R
TH
F O
R T
W O
R
TH
, T
EX
AS
R
EP
U
R
PO
SE
D
FA
C
B U
IL
D
IN
G
TO
C
LA
SS
R
O O
M F
AC
IL
IT
Y
PN
: 4
AP
R
IL
J.
R
O
BB
IN
S
J.
R
O
BB
IN
S
M
AT
TH
EW
P . V
AV
R
A, P
.E
C H
IE
F, S
TR
U C
TU
R
AL
S
EC
TI
O N
S-121
M
IS
CE
LL
AN
EO
US
D
ET
AI
LS
I
N . A
LM
AS
R I
Enter Project Name
3/4" = 1'-0"1 EXTERIOR CMU WALL WINDOW OPENING
3/4" = 1'-0"2
EXTERIOR CMU WALL DOOR OPENING
(3'-4")
3/4" = 1'-0"4 FIRE BARRIER DOUBLE DOOR OPENING
3/4" = 1'-0"5 INTERIOR WALL DOOR OPENING
3/4" = 1'-0"6
TYP. CMU WALL SECTION (FILL IN
OPENINGS)1
3/4" = 1'-0"3
EXTERIOR CMU WALL DOOR OPENING
(4'-0")
W
G
B4
EXISTING WOOD
TRUSS BOT CHORD
SLOTTED CHANNEL FRAMING TO
SPAN ACROSS 4 TRUSSES MIN (8'-0"
MAX. O.C.), LOCATE AT TRUSS BOT
CHORD PANEL POINTS TO
SUPPORT NEW SPRINKLER PIPING,
EACH CONNECTION OF THE
SLOTTED CHANNEL FRAMING SHALL
HAVE MIN. 200LBS SUPPORT LOAD
FROM EACH TRUSS, AND 500LBS
BETWEEN THE SLOTTED CHANNEL
FRAMING AND PIPE
NEW SPRINKLER PIPE 4" DIA. MAX.
SHALL BE PLACED IN THE CENTER OF
EACH UNISTRUT
SLOTTED CHANNEL FRAMING TO
SPAN ACROSS 4 TRUSSES MIN
(8'-0" MAX. O.C.), LOCATE AT TRUSS
BOT CHORD PANEL POINTS TO
SUPPORT NEW SPRINKLER PIPING,
EACH CONNECTION OF THE
SLOTTED CHANNEL FRAMING
SHALL HAVE MIN. 200LBS SUPPORT
LOAD FROM EACH TRUSS, AND
500LBS BETWEEN THE SLOTTED
CHANNEL FRAMING AND PIPE
NEW SPRINKLER PIPE 4" DIA.
MAX. SHALL BE PLACED IN THE
CENTER OF EACH SLOTTED
CHANNEL FRAMING
EXISTING WOOD
TRUSS
NOTE:
SLOTTED CHANNEL FRAMING SHALL COMPLY ALL REQUIREMENTS
WITH METAL FRAMING MANUFACTURER'S ASSOCIATION - 4.
EXISTING WOOD
TRUSS BOT CHORD
SLOTTED CHANNEL FRAMING TO
SPAN ACROSS 3 TRUSSES MIN (8'-0"
MAX. O.C.), LOCATE AT TRUSS BOT
CHORD PANEL POINTS TO
SUPPORT NEW SPRINKLER PIPING,
EACH CONNECTION OF THE
SLOTTED CHANNEL FRAMING SHALL
HAVE MIN. 200LBS SUPPORT LOAD
FROM EACH TRUSS, AND 500LBS
BETWEEN THE SLOTTED CHANNEL
FRAMING AND PIPE
NEW SPRINKLER PIPE 4" DIA. MAX.
SHALL BE PLACED IN THE CENTER OF
EACH SLOTTED CHANNEL FRAMING
SLOTTED CHANNEL FRAMING TO
SPAN ACROSS 3 TRUSSES MIN
(8'-0" MAX. O.C.), LOCATE AT TRUSS
BOT CHORD PANEL POINTS TO
SUPPORT NEW SPRINKLER PIPING,
EACH CONNECTION OF THE
SLOTTED CHANNEL FRAMING
SHALL HAVE MIN. 200LBS SUPPORT
LOAD FROM EACH TRUSS, AND
500LBS BETWEEN THE SLOTTED
CHANNEL FRAMING AND PIPE
NEW SPRINKLER PIPE 4" DIA. MAX.
SHALL BE PLACED IN THE CENTER
OF EACH SLOTTED CHANNEL
FRAMING
EXISTING WOOD
TRUSS
NOTE:
SLOTTED CHANNEL FRAMING SHALL COMPLY ALL REQUIREMENTS
WITH METAL FRAMING MANUFACTURER'S ASSOCIATION - 4.
4'
0"
5'
- 0
NEW C4x5.4KNEE
BRACE (TYP.)
EXISTING STEEL
BEAMS (TYP.)
NEW C4x5.4 KNEE
BRACE (TYP.)
EXISTING COLUMN
(TYP.)
3/16
TYP.
EXISTING C3x4.1
KNEE BRACE (TYP.)
NOTE: PROVIDE @ ALL COLUMN KNEE BRACES
SHEET
NUMBER
D ra w n by
D es ig ne d by
Su bm itt ed b y:
Sh ee t S iz e
AN
SI
D
D at e:
C on tra ct
N o.
So lic ita tio n N o.
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
FO
R
T W
O R
TH
D
IS
TR
IC
T
TA
YL
O R
S T
FO
R
T W
O R
TH
, T
EX
AS
C he ck ed b y:
US Army Corps of Engineers ®
A
R ev
M ar k D es cr ip tio n Tr ac ki ng N o.
Ac tio n
D at e
EN
G
IN
EE
R
IN
G
C O
N
ST
R U
C
TI
O N
D
IV
IS
IO
N
EN
G
IN
EE
R
IN
G
B R
AN
C
H
PLOT DATE:
2 3 4 5 6 7 8 9 10
B
C
D
E
F
G
Fort Worth District
FILE PATH:
4/9/2021 3:59:33 PM
N O
R
TH
F O
R T
W O
R
TH
, T
EX
AS
R
EP
U
R
PO
SE
D
FA
C
B U
IL
D
IN
G
TO
C
LA
SS
R
O O
M F
AC
IL
IT
Y
PN
: 4
AP
R
IL
J.
R
O
BB
IN
S
J.
R
O
BB
IN
S
M
AT
TH
EW
P . V
AV
R
A, P
.E
C H
IE
F, S
TR
U C
TU
R
AL
S
EC
TI
O N
S-122
M
IS
CE
LL
AN
EO
US
D
ET
AI
LS
II
N . A
LM
AS
R I
Enter Project Name
NTS1
SPRINKLER PIPE PARALLEL TO WOOD
TRUSSES SUPPORT SCHEMATIC DETAIL
NTS2
SPRINKLER PIPE PERPENDICULAR TO
WOOD TRUSSES SUPPORT SCHEMATIC
DETAIL
3/4" = 1'-0"3
TYPICAL KNEE-BRACE STRENGTHENING
DETAIL
W
G
B4
D ra w n by
D es ig ne d by
Su bm itt ed b y:
Sh ee t S iz e
AN
SI
D
D at e:
C on tra ct
N o.
So lic ita tio n N o.
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
FO
R
T W
O R
TH
D
IS
TR
IC
T
TA
YL
O R
S
TR
EE
T
FO
R
T W
O R
TH
, T
EX
AS
C he ck ed b y:
US Army Corps of Engineers ®
A
R ev
M ar k D es cr ip tio n Tr ac ki ng N o.
Ac tio n
D at e
EN
G
IN
EE
R
IN
G
C O
N
ST
R U
C
TI
O N
D
IV
IS
IO
N
EN
G
IN
EE
R
IN
G
B R
AN
C
H
PLOT DATE:
2 3 4 5 6 7 8 9 10
B
C
D
E
F
G
Fort Worth District
FILE PATH:
7/28/2021 2:28:12 PM
N O
R
TH
F O
R T
H O
O D
, T
EX
AS
R
EP
U
R
PO
SE
D
FA
C
B U
IL
D
IN
G
TO
C
LA
SS
R
O O
M F
AC
IL
IT
Y
PN
: 4
AP
R
IL
J.
K
AS
PA
R
J.
M
ET
O
YE
R
JA
M
ES
K
AS
PA
R , F
.P .E
D
IS
TR
IC
T
FI
R
E
PR
O
TE
C
TI
O N
EN
G
IN
EE
R
LS001
LI
FE
S
AF
ET
Y
PL
AN
C O
DE
C
RI
TE
RI
A
J.
K
AS
PA
R
PROJECT NAME
OCCUPANCY CLASSIFICATION
CLASSROOM ASSEMBLY A-3 NFPA 101 12.1.2
IBC 303.4
OFFICES, BUSINESS GROUP B NFPA 101 38.1.2
IBC 304.1
OCCUPANCY SEPARATION
ASSEMBLY FROM BUSINESS 1-HOUR IBC TABLE 508.4
(W/ AUTOMATIC SPRINKLER SYSTEM)
OCCUPANT LOAD CALCULATIONS
SPACE LOAD FACTOR OCCUPANT LOAD
OFFICE (BUSINESS USE) 150 SF/PN NFPA 101 (TABLE 7.3.1.2) 1417 SF/150 = 10
COLLABORATION ROOM (BUSINESS USE) 15 SF/PN NFPA 101 (TABLE 7.3.1.2) 846 SF/15 = 57
BREAKROOM (ASSEMBLY USE) 15 SF/PN NFPA 101 (TABLE 7.3.1.2) 82 SF/15 = 7
UTILITY SPACES (MECH, ELEC, JAN.) 500 SF/PN UFC 3-600-01 (TABLE 10-1) 662 SF/500 = 5
UTILITY SPACES (COMM) 300 SF/PN UFC 3-600-01 (TABLE 10-1) 93 SF/300 = 1
STORAGE SPACES 500 SF/PN NFPA 101 (TABLE 7.3.1.2) 535 SF/500 = 4
ASSEMBLY (CLASSROOM AND EST) 15 SF/PN NFPA 101 (TABLE 7.3.1.2) 4530 SF/15 = 303
ASSEMBLY (WAITING AREA) 5 SF/PN NFPA 101 (TABLE 7.3.1.2) 553 SF/5 = 111
OFFICE (BUSINESS USE) 150 SF/PN NFPA 101 (TABLE 7.3.1.2) 744/150 = 7
OCCUPANT LOAD CALCULATED = 516
CONSTRUCTION CLASSIFICATION
CONSTRUCTION TYPE III-B NON-COMBUSTIBLE, UNPROTECTED IBC 602.2
(FULLY SPRINKLERED)
MAXIMUM ALLOWABLE HEIGHT - FEET. 75 FEET (FULLY SPRINKLERED) IBC TABLE 504.3
(BUSINESS GROUP B, ASSEMBLY GROUP A)
MAXIMUM ALLOWABLE HEIGHT - STORIES. 4 STORIES (FULLY SPRINKLERED) IBC TABLE 504.4
(BUSINESS GROUP B)
(ASSEMBLY GROUP A-3) 3 STORIES (FULLY SPRINKLERED) IBC TABLE 504.4
MAXIMUM ALLOWABLE AREA - SF. 76000 SF (FULLY SPRINKLERED) IBC TABLE 506.2
(BUSINESS GROUP B)
(ASSEMBLY GROUP A-3) 38000 SF (FULLY SPRINKLERED) IBC TABLE 506.2
CONSTRUCTION CLASSIFICATION AS DESIGNED
CONSTRUCTION TYPE III-B (FULLY SPRINKLERED)
BUILDING HEIGHT - FEET. 28'-9"
BUILDING HEIGHT - STORIES. 1 STORIES
MAXIMUM AREA PER STORY - SF. 11,464 SF 1ST FLOOR.
FIRE RESISTIVE REQUIREMENTS
FIRE BARRIERS EXTEND FROM FLOOR SLAB TO SLAB IBC 707.5
ABOVE OR ROOF DECK
DOORS WHERE RATED, 1-HOUR FIRE PARTITION IBC-TABLE 716.5
(AT CORRIDOR WALLS) REQUIRE 20-MINUTE
RATED FIRE DOORS; 1- HOUR RATED FIRE
PARTITION (AT OTHER WALLS) REQUIRES
45-MINUTE RATED FIRE DOORS
FIRE PROTECTION SPRINKLER SYSTEM PER NFPA 101 SECTION 9.7 NFPA 101
SECTION 9.7
SHAFT ENCLOSURES 1-HOUR < FOUR STORIES IBC-713.4
CORRIDORS (FULLY SPRINKLERED BUILDING) 0-HOUR NFPA 101
(BUSINESS, GROUP B) 38.3.6.1, 12.3.6
(ASSEMBLY, GROUP A-3)
INTERIOR WALL/CEILING FINISH AND TRIM CLASS A OR B NFPA 101
(FULLY SPRINKLERED BUILDING) 10.2.2, 38.3.3.2, 12.3.3.3
(BUSINESS GROUP B)
INTERIOR FLOOR FINISH CLASS I OR II NFPA 101
10.2.7, 38.3.3.3, 12.3.3.5
FIRE PROTECTION REQUIREMENTS
PORTABLE FIRE EXTINGUISHERS PROVIDE IN NEW “BUSINESS” AND “ASSEMBLY” NFPA 101 9.9, 38.3.5
OCCUPANCIES, WHERE REQUIRED BY NFPA 101 NFPA 10 6.2.1.1
AND AS INDICATED IN UFC 3-600-01. UFC 3-600-01 9-17
EXIT REQUIREMENTS
MINIMUM NUMBER OF EXITS (PER STORY) 3 - (OCCUPANT LOAD > 500) NFPA 101
7.4.1.2, 12.2.4.1.
MINIMUM SEPARATION BETWEEN EXITS 1/3 OF BUILDING OR AREA SERVED, DIAGONAL NFPA 101, 7.5.1.3.3
MAXIMUM TRAVEL DISTANCE TO EXITS "NEW ASSEMBLY" NFPA 101
OCCUPANCY = 400-FEET 12.2.6.2(1)
"B" OCCUPANCY = 300 FT NFPA 101 38.2.6.3
EXIT REQUIREMENTS
MEASUREMENT OF TRAVEL DISTANCE TO EXITS STARTING FROM THE MOST REMOTE POINT NFPA 101 7.6
SUBJECT TO OCCUPANCY, CURVING AROUND
ANY CORNERS OR OBSTRUCTIONS, WITH A
12-INCH CLEARANCE THEREFROM. TERMINATING
AT ONE OF THE FOLLOWING:
a) CENTER OF THE DOORWAY
b) OTHER POINT AT WHICH THE EXIT BEGINS
MAXIMUM COMMON PATH OF EGRESS TRAVEL "NEW ASSEMBLY" OCCUPANCY = 20' ANY OCC. NFPA 101, 12.2.5.1.2
75' WHERE THE PATH SERVES NOT MORE THAN 50 OCC.
"B" OCCUPANCY = 100-FT WITH FULLY SPRINKLERED TABLE 38.2.5.3.1
MAX DISTANCE DEAD-END CORRIDOR "NEW ASSEMBLY" OCCUPANCY = 20’ NFPA 101 TABLE 12.2.5.1.3
(FULLY SPRINKLERED BUILDING) "B" OCCUPANCY = 50' NFPA 101 38.2.5.2.1
MINIMUM TOTAL EXITS WIDTH:
STAIRS 169 PN X 0.3 = 50.7 USE 51 NFPA 101 TABLE 7.3.3.1
CORRIDORS 169 PN X 0.2 = 33.8 USE 34 NFPA 101 TABLE 7.3.3.1
MINIMUM STAIR WIDTH 44" MINIMUM (>50 OCCUPANTS, <2000) NFPA 101 TABLE 7.2.2.2.1.2(B)
MAXIMUM VERTICAL DISTANCE 12-FEET NFPA 101 TABLE 7.2.2.2.1.2(A)
BETWEEN LANDINGS
MINIMUM CORRIDOR WIDTH PROVIDED = 54”
STAIRWAY ENCLOSURE 1-HOUR RATED NFPA 101 7.1.3.2
DOOR OPENINGS DOOR OPENINGS IN MEANS OF EGRESS SHALL BE NFPA 101 7.2.1.2.3.2
NOT LESS THAN 32”.
ACTUAL DOOR OPENINGS PROVIDED AT EACH EGRESS = 36”
SEPARATION FROM HAZARDS
MECH = PROVIDING 1 HR FIRE BARRIER NFPA 101 8.7.1.1, 8.7.1.2
DUE TO THE EXISTING MECH ROOM WALLS
BEING RATED FOR 1HR WE ARE MAINTAINING
THAT RATING. NFPA 101 ONLY REQUIRES
SMOKE PARTITION(S) FOR THESE WALLS.
REPURPOSE DFAC BUILDING 56471 TO CLASSROOM FACILITY
NORTH FORT HOOD (NFH)
GENERAL PROJECT INFORMATION
a) PROJECT NAME: REPURPOSE DFAC
BUILDING 56471 TO
CLASSROOM FACILITY
NORTH FT HOOD
b) PROJECT NUMBER: 490407
c) LOCATION: NFH, TEXAS
d) BUILDING USE: CLASSROOM FACILITY
e) BUILDING AREA 11,464 SF
f) BUILDING HEIGHT (FT) 28'-9"
g) STORIES ABOVE GRADE: 1
h) STORIES BELOW GRADE: N/A
APPLICABLE CODES
UFC 1-200-01 (10-09-2019)
UFC 3-600-01, WITH CHANGE 5 (08-12-2020)
IBC 2018
NFPA 101, 2018
BUILDING USE
a) PRIMARY CLASSROOM 1ST FLOOR (7,385 SF)
b) SECONDARY OFFICES 1ST FLOOR (4,079 SF)
W
G
B4
REF.
EF
R
EF
172 SF
STORAGE
500 SF/PN
1 PN
63 SF
BUSINESS
150 SF/PN
1 PN
615 SF
BUSINESS
150 SF/PN
5 PN
161 SF
ELECTRICAL
500 SF/PN
1 PN
111 SF
MECH
500 SF/PN
1 PN
513 SF
MECH
500 SF/PN
2 PN
81 SF
ASSEMBLY
15 SF/PN
7 PN
93 SF
TELECOM
500 SF/PN
1 PN
223 SF
BUSINESS
150 SF/PN
2 PN
241 SF
BUSINESS
150 SF/PN
2 PN
130 SF
BUSINESS
150 SF/PN
1 PN
1962 SF
ASSEMBLY
15 SF/PN
131 PN
124 SF
STORAGE
500 SF/PN
1 PN
169 SF
BUSINESS
150 SF/PN
2 PN
2638 SF
ASSEMBLY
15 SF/PN
176 PN
187 SF
STORAGE
500 SF/PN
1 PN
1117 SF
ASSEMBLY
15 SF/PN
75 PN
230 SF
BUSINESS
150 SF/PN
2 PN
224 SF
BUSINESS
150 SF/PN
2 PN
KB
3'-0"/180 3'-0"/180
3'-0"/180
OCCUPANCY "A-3
OCCUPANCY "B"
' T
R
AV
EL
D
IS
TA
N C
E
136' TRAVEL DISTANCE
68' TRAVEL DISTANCE
61' TRAVEL DISTANCE
' T
R
AV
EL
D
IS
TA
N C
E
496 SF
ASSEMBLY
5 SF/PN
100 PN
99 SF
STORAGE
500 SF/PN
1 PN
38 SF
JAN.
500 SF/PN
1 PN
3'-8"/ 220
6'-0"/360
6'-0"/360
6'
T R
AV
EL
D
IS
TA
N
C E
FE
C
FEB
FEC FEC
68' TRAVEL
DISTANCE
EGRESS TRAVEL PATH/DISTANCE
EXIT DIRECTION
3'-0"/180
TYPICAL FOR ALL EXIT EGRESS
EXIT CAPACITY (EXIT WIDTH/MAX CAPACITY PN)
NOTES:
1. WHERE "B" OCCUPANCY IS LABLED, EQUIVALENT
OCCUPANCY PER NFPA 101 IS "BUSINESS".
2. WHERE "A-3 OCCUPANCY IS LABELED, EQUIVALENT
OCCUPANCY PER NFPA 101 IS "ASSEMBLY".
3. REFER TO FA AND LIGHTING PLANS FOR SMOKE DETECTOR
AND EXIT SIGN LOCATIONS.
4. THE ASSEMBLY SPACES SHOWN ON THE PLAN ARE
ANCILLARY TO THE MAIN OCCUPANCY, THEREFORE NO
SEPARATION IS REQUIRED.
5. THE COLLABORATION ROOM IS PART OF THE BUSINESS
OCCUPANCY TYPE, THEREFORE NO SEPARATION IS
REQUIRED.
6. WHERE BUSINESS OCCUPANCY IS LABELED FOR THE
OPEN OFFICE SPACE, THE MAX. PROBABLE OCCUPANTS
FOR THAT SPACE IS 24 PERSONS.
OCCUPANCY TYPE: "A-3" IBC, ASSEMBLY NFPA 101
ROOM SEPARATIONS (SF LIMITS)
EGRESS STARTING POINT
1 HR FIRE BARRIER
KNOX BOXKB
OCCUPANCY TYPE: "B" IBC, "BUSINESS" NFPA 101
FEC SEMI RECESSED FIRE EXTINGUISHER CABINET
FEB FIRE EXTINGUISHER BRACKET
SHEET
NUMBER
D ra w n by
D es ig ne d by
Su bm itt ed b y:
Sh ee t S iz e
AN
SI
D
D at e:
C on tra ct
N o.
So lic ita tio n N o.
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
FO
R
T W
O R
TH
D
IS
TR
IC
T
TA
YL
O R
S
TR
EE
T
FO
R
T W
O R
TH
, T
EX
AS
C he ck ed b y:
US Army Corps of Engineers ®
A
R ev
M ar k D es cr ip tio n Tr ac ki ng N o.
Ac tio n
D at e
EN
G
IN
EE
R
IN
G
C O
N
ST
R U
C
TI
O N
D
IV
IS
IO
N
EN
G
IN
EE
R
IN
G
B R
AN
C
H
PLOT DATE:
2 3 4 5 6 7 8 9 10
B
C
D
E
F
G
Fort Worth District
FILE PATH:
4/15/2021 1:49:25 PM
N O
R
TH
F O
R T
H O
O D
, T
EX
AS
RE
PU
RP
O
SE
D
FA
C
BU
IL
DI
NG
TO
C
LA
SS
RO
O
M F
AC
IL
IT
Y
PN
: 4
AP
R
IL
J.
M
ET
O
YE
R
J.
M
E T O
YE
R
JE
N
N
IF
ER
A
. D eW
IT
T, R .A
C
H
IE
F, A
R C
H
IT
EC
TU
R E
SE
C
TI
O
N
LS101
LI
FE
S
AF
ET
Y
PL
AN
S.
W
EI
SS
EN
ST
EI
N
PROJECT NAME
1/8" = 1'-0"A1 LIFE SAFETY PLAN
GENERAL PROJECT INFO
a. PROJECT NAME: DFAC 56471 REPURPOSE TO
CLASSROOM FACILITY
b. PROJECT…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .