This document contains a federal contract opportunity solicitation for facility support services and the related site plans for the work locations. The solicitation seeks a contractor to provide facility operations and maintenance, custodial, solid waste, grounds maintenance, and pest control services at two U.S. Army Garrison Miami sites totaling over 800,000 square feet of facilities. The requirement is set aside for 8(a) small businesses and is for a 12-month base period and four 1-year option periods. Site visits will be held on March 7-8, 2024 at the locations in Doral and Homestead, with a limit of two attendees per firm who must register by February 27. The site plans provide details on the existing conditions and scope of work at the Homestead Air Reserve Base location, including electrical, lighting, and landscape elements.
View the file
Other files for this federal contract opportunity
Show all 50
Facility Support Services (Consolidated) has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
I.C. Thomasson Associates, Inc.
CONSULTING ENGINEERS
2950 KRAFT DRIVE, SUITE 500
NASHVILLE, TN. 37211
PHONE (615) 346-3400
FAX (615) 346-3550
ICT Project No. 110189
S P
E C
IA
L O
P E
R A
T
IO
N S C
O M
M A
N D
(S O
C S
O U
T H
H E
A D
Q U
A R
T E
R S B
U
IL
D
IN
G
H O
M E
S T
E A
D A
F B F
L O
R
ID
A
S
T O
A c
A
B C D
A B C D
E F G H I
E F G
H I
Sheet
Reference
Number:
D e s c ri p ti o n
S y m b o l
A p p ro v e d
D a te of Engineers
Mobile District
US Army Corps
I.
S .O S h e e t F il e N a m e
S o li c it a ti o n N u m b e r:
R e v ie w e d B y
C h e c k e d B y
D e s ig n e d B y
D ra w n B y
C A
D D C o d e
D a te
11036
M B E
E
K A J
P H ,L
H ,M
P ,B
K
C R
T S
K
J U
N E
A S -B
U
IL
T J
U N
E
MH
SOC SOUTH
HEADQUARTERS
BUILDING
FFE = 9.00
G R
A V
E L
R
O A
D
BFA
WV
ELECTRICAL
PANELS
GENATOR
DIESEL
TANK
COMMUNICATIONS TOWER
0+00
1+00
2+00
3+00
4+00
5+00
6+00
7+00
8+00
9+00
10+00
11+00
11+18
BP: 0+00.00
N 422367.46
E 855741.77
EP: 2+18.30
N 422367.46
E 855960.07
0+00
1+00
2+00
3+00
4+00
5+00
6+00
7+00
8+00
9+00
10+00
11+00
11+21
BP: 0+00.00
N 423015.20
E 856324.32
EP: 11+21.34
N 421893.86
E 856324.36
0+00
1+00
1+58
N90°00’00"E
580.38’
N90°00’00"E
364.25’
S °0
’0
E
.8
N90°00’00"E
588.44’
BP: 0+00.00
N 422274.95
E 855960.07
EP: 3+64.25
N 422274.95
E 856324.32
BP: 0+00.00
N 422138.95
E 855960.07
EP: 3+64.25
N 422138.95
E 856324.32
BP: 0+00.00
N 422070.45
E 855960.07
EP: 3+64.25
N 422070.45
E 856324.32
N90°00’00"E
364.25’
N90°00’00"W
165.95’N90°00’00"E
141.12’
N90°00’00"E
364.25’
N90°00’00"E
364.25’
N90°00’00"E
218.30’
S °0
’0
E
.8
S °0
’0
"E
.3
N90°00’00"E
580.38’
N °0
’0
E
.7
0+00
1+00
1+40
N90°00’00"W
155.63’
S4 9° ’2 2"
W
2.
B E
A R I N
G
B A
S E
L I N
E
Bikini Boulevard Bikini Boulevard
Bi ki ni B ou le va rd
Bi ki ni B ou le va rd
T u rn e r S tr e e t
T u rn e r S tr e e t
T u rn e r S tr e e t
St. Lo Boulevard
St.
Lo Bo ule var d
R abu al R oad
R abu al R oad
Conservation
Easement
HH
HH
HH
HHHH
HH
HH
CL OF A SAW CUT IN THE
ASPHALT PAVEMENT
ASPHALT PAVEMENT
ASPHALT
PAV
EMENT
BI
KE
LANE
A S P
H A L T
P
A V
E M E
N T
A S P
H A L T
P
A V
E M E
N T
A S P
H A L T
P
A V
E M E
N T
ASPHALT
PAVEMENT
ASPHALT PAVEMENT
ASPHALT PAVEMENT
A S
P H
A
T
P
V E
M E
N T
A S
P H
A
V E
M E
N T
A S
P H
A
V E
M E
N T
PERIMETER
SWALE (TYP.)
P E R
IM
E T E R
S W
A L E
(T
Y P
P E
R
IM
E T E
R
S W
A L E
(T
Y P
P E R
IM
E T E R
S W
A L E
(T
Y P
P E R
IM
E T E R
S W
A L E
(T
Y P
PERIMETER
SWALE (TYP.)
S W
A L
E
T
Y P
S W
A L
E
T
Y P
FND.
CONC.
MONUMNET
FND.
CONC.
MONUMNET
FND.
CONC.
MONUMNET
F N
D
C O
N C
M O
N U
M N E T
F N
D
N
IL
N
D
D
IS
C
L .B
F N
D
C O
N C
M O
N U
M N E T
F N
D
C O
N C
M O
N U
M N E T
F N
D
C O
N C
M O
N U
M N E T
BP: 0+00.00
N 422785.89
E 855735.88
EP: 5+88.44
N 422785.89
E 856324.32
BP: 0+00.00
N 422911.70
E 855960.07
EP: 5+80.38
N 422911.70
E 856540.45
BP: 0+00.00
N 422837.07
E 856479.95
EP: 1+55.63
N 422837.07
E 856324.32
BP: 0+00.00
N 422848.70
E 855960.07
EP: 3+64.25
N 422848.70
E 856324.32
BP: 0+00.00
N 423004.16
E 855960.07
EP: 11+17.84
N 421886.32
E 855960.07
BP: 0+00.00
N 423015.20
E 856324.32
EP: 11+21.34
N 421893.86
E 856324.36
BP: 0+00.00
N 422204.45
E 855960.07
EP: 1+41.12
N 422204.45
E 856101.19
BP: 0+00.00
N 422204.95
E 856324.35
EP: 1+65.95
N 422204.95
E 856158.40
BP: 0+00.00
N 422819.44
E 856540.45
EP: 1+57.76
N 422977.20
E 856540.45
BP: 0+00.00
N 422837.07
E 856479.95
EP: 1+55.63
N 422837.07
E 856324.32
BP: 0+00.00
N 422819.44
E 856540.45
EP: 1+57.76
N 422977.20
E 856540.45
BP: 0+00.00
N 422706.32
E 857349.83
EP: 3+72.27
N 422462.28
E 857068.70
HH
HH
HH
SS
SS
SS
S S
SCALE:
ELECTRICAL - SITE PLAN
1"=100’-0"
PPPP
LEGENDLEGEND
ALL EXTERIOR POLES TO BE RATED TO WITHSTAND HURRICANE
CATEGORY 5 WIND SPEEDS.
ALL EXTERIOR LIGHTING TO BE ON A TIMECLOCK AND
N
S-2
S
S
S-2
S-2
S-2
S-2
S-2 S-2
S-2
S
S
S
B.
S-4
PROVIDE INTEGRAL PHOTOCELL IN FIXTURE INDICATED.
PROVIDE INTEGRAL TRANSFORMER TO STEP VOLTAGE
FROM 277V TO 120V FOR CAMERA AND INTEGRAL BASE
MOUNTED DUPLEX RECEPTACLE.
8.
C. NO OVERHEAD LINES WILL BE ADDED FOR THIS PROJECT.
ALL ELECTRICAL LINES TO BE UNDERGROUND.
LC-1
H2A-5
LC-2
H2A-8
CONNECT TO AMPD-13 IN ANTENNA BUILDING. FIXTURE TO
BE 120V.
D. PRIMARY CABLING AND UNDERGROUND CONDUIT TO BE
PROVIDED BY FPL. CONDUIT TO BE INSTALLED BY
CONTRACTOR AND CABLING BY FPL.
ES-100
E L E
C T
R
IC
A L S
IT
E P
L A
N
CONNECT TO PHOTOCELL CONTROLLED CONTACTOR PANEL WITH
2-#10,1#10G IN 1" DIRECT BURIED CONDUIT.
PHOTOCELL CONTROL FOR OPERATION. PHOTOCELL
TO BE ON ROOF ABOVE ELECTRICAL ROOM 2056.
TIME CLOCK AND CONTACTOR PANEL IN ROOM 2056.
A. 1.
2.
3.
4.
5.
6.
7.
9.
NOTES THIS SHEET:
FPL TO DESIGN THIS PORTION. FPL TO SELECT HOW
POWER FEED WILL BE CONNECTED. COORDINATE FINAL
LOCATIONS WITH FPL. COORDINATE METER LOCATION
FOR EACH SERVICE WITH FPL.
LIGHTED SECURITY BOLLARDS. CONNECT TO PHOTOCELL CONTROLLED
CONTACTOR PANEL. COORDINATE EXACT QUANTITIES WITH SITE/CIVIL
DRAWINGS. PROVIDED BY CIVIL CONTRACTOR.
REFERENCE LANDSCAPE PLANS ON SHEET L-108 FOR PROPOSED
FOUNTAIN LAYOUT. 10.
PROVIDE BONDING/GROUNDING FOR METAL PIPING, ELECTRICAL
EQUIPMENT, AND PANELBOARDS IN ACCORDANCE WITH ARTICLE
680 OF NEC.
11.
12.
PROVIDE SINGLE POINT CONNECTION TO PREWIRED POOL
CONTROL PANEL IN ACCORDANCE WITH MANUFACTURER’S
WRITTEN INSTALLATION GUIDELINES. COMPLETE INSTALLATION
SHALL BE IN COMPLIANCE WITH ARTICAL 680 OF THE NEC.
REFERENCE L-111 FOR ADDITIONAL REQUIREMENTS.
INSTALL NEW STEP LIGHT MINIMUM OF 5 FEET
HORIZONTALLY FROM INSIDE WALL OF FOUNTAIN.
UNITS SHALL BE RIGIDLY ATTACHED PER NEC 680.
BRANCH CIRCUIT SHALL INCLUDE GFCI PROTECTION.
REFERENCE SHEET L-108 FOR ADDITIONAL
REQUIREMENTS.
L1A-85
VIA ’LC-3’
’F’ ’F’ ’F’
’F’ ’F’ ’F’
’E’ ’E’
’E’
’E’
’E’ ’E’
’E’
’E’ ’E’
H2A-6
VIA ’LC-1’
’I’’I’’I’’I’’I’
’I’ ’I’ ’I’ ’I’ ’I’
L1A-54
VIA ’LC-3’
J
L1A-86
CONNECT TO CONTACTOR PANEL WITH 2-#4,1#4G IN 2" DIRECT
BURIED CONDUIT.
/2
/1
A
M E
N D
M E
N T
NOT USED.
S
S
S
S
S
S
S
S
S-2
S-2
S
S
SP
SP SP
SP SP
S-4
SP
A M
E N
D M
E N
T
LM1A-13
H2A-12
LC-1
PROVIDE ADDITIONAL #10 AWG CONDUCTOR NOT
CONNECTING TO LIGHTING CONTROL CONTACTOR
TO THIS POLE FOR CONNECTION TO INTEGRAL
TRANSFORMER IN POLE TO STEP VOLTAGE FROM
277V TO 120V FOR CAMERA.
/1
/1
H2A-13
LC-2
A
M E
N D
M E
N T
/1
/1
/1
/1
A
M E
N D
M E
N T
M
IN
E
E
C
F
R
ANTENNA
BUILDING
C
C
A A
A A
AA
SEE SHEET EP-115 FOR
ADDITIONAL
PLANS IN THIS AREA.
CONCRETE ENCASED
SERVICE ENTRANCE
RISER WITH BLDG
BRANCH FEED INCLUDED.
PROPOSED
UNDERGROUND
ELECTRICAL PRIMARY
EXISTING FPL OVERHEAD 13.2KV LINE
NEW RISER POLE WITH FUSED
CUTOUT FOR POWER TO
HEADQUARTERS BUILDING
CHILLER/UTILITY SUPPORT
BUILDING
TRANSFORMER
PAD
SIMILAR TO S EXCEPT
TWO TYPE S FIXTURES.
EXISTING FPL
OVERHEAD 13.2KV LINE
GENERAL NOTES:
PORT JUNCTION
48"X36"
SPLICE BOX
RISER POLE
WITH FUSED
CUTOUT
NEW POLE WITH THREE
POLE MOUNTED
TRANSFORMERS TO
PROVIDE 208Y/120
VOLT SERVICE TO THE
ANTENNA PAD. COORDINATE
METER LOCATION WITH FPL
LITHONIA LIGHTING POLE.
STC 40 12-48X T25 OR EQUAL.
MOUNT ONE FIXTURE TYPE S
AND CONNECT AS INDICATED.
SIMILAR TO S EXCEPT
FOUR TYPE S FIXTURES.
WATER METER
LITHONIA LIGHTING POLE.
STC 20 7-24X T25 OR EQUAL.
MOUNT ONE FIXTURE TYPE S
AND CONNECT AS INDICATED.
SP
S
A
S -B
U
IL
T
MONUMENT SIGN
C C
/2
PPPP
PPPP
PPPP
PPPP