Forestry DSA Certification Form.pdf
PDF 108 KB Posted
- Attached to
- DCNR F. D. 7 DSA Thomas Dam Road
- Solicitation number
- 6100037091
- Issued by
- Union County, Milroy CDP, Pennsylvania
About this file
This document is a Driving Surface Aggregate (DSA) Certification Form for the Dirt and Gravel Road Maintenance Program in Pennsylvania. The form certifies that the aggregate shipped to a job site meets all specifications and quality requirements set forth by the Pennsylvania Department of Conservation and Natural Resources (DCNR). The key specifications include gradation requirements for various sieve sizes, an LA Abrasion loss limit of less than 40%, a pH range of 6 to 12.45, and a Plasticity Index not to exceed 6. The form must be completed and signed by the authorizing agent or a PennDOT certified Aggregate Technician. The document outlines the requirements for the composition of the fines passing the #200 sieve and the use of lime kiln dust or cement kiln dust to account for up to 50% of those fines. It also specifies that the aggregate must be delivered and placed at the optimum moisture content, which is to be determined using the Proctor Test.
The document indicates that Driving Surface Aggregate is now approved by PennDOT for state purchasing, and that all components of the aggregate mix must be derived from crushed rock material that meets the program specifications. The certification form must be completed for each project and shipment of DSA to ensure compliance with the program's requirements.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Map_Thomas Dam Road.pdf | ||
| Reciprocal Limitations Act Form.doc | DOC document | |
| Terms and Conditions.pdf | ||
| Thomas Dam Road SOW_1-20-16.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Driving Surface Aggregate Certification Dirt and Gravel Road Maintenance Program
Gradation for This Lot % Passing pH:______
Date: _____________________________
Sworn and subscribed before me
This day____________________________________
Note: The authorizing agent or responsible party should sign their name and print their name below their signature. If the signatory is a Penn-DOT certified Aggregate Technician add the certification number on title line and no notary is required.
Specification Range
65-95
Sieve Size
Title of Authorizing Agent:
30-65
Print Name of Authorizing Agent:
#200
1.5"
0.75"
#4
#16
Authoring Agent Signature:
Optimum Moisture %: __________
10-15
% Passing
15-30
Notary Public
My commission expires: _________________________________
Company: _______________________________________________________________________________
Plant Location: ___________________________________________________________________________
Parent Stone Type: _______________________________________________________________________
Tonnage Represented: ____________________________________________________________________
Project: _________________________________________________________________________________
L.A. Abrasion: _________ Plasticity Index: __________
This record is to certify that the agggregate shipped to the above-referenced job site meets all DCNR specifications and quality requirements.
Driving Surface Aggregate Specifications Dirt and Gravel Road Maintenance Program
Note that “Driving Surface Aggregate” is now approved by PennDOT for State purchasing.
Pursuant to Section 9106 of the PA Vehicle Code, all Driving Surface Aggregate (DSA) is to be derived from natural stone formations. Stone is defined as rock that has been crushed; rock is defined as consolidated mineral matter. All components of the aggregate mix ate to be derived from crushed rock material that meets program specification for abrasion resistance, pH and freedom from contaminants.
Minus #200 fine composition:
The fines passing the #200 sieve must be rock material. No clay or silt soil may be added. Limestone material passing the #200 sieve may be used to make up a deficit in the distribution of sandstone aggregate rock, and vice versa. All added material passing the #200 sieve must be derived from rock material that conforms to program specifications. Lime kiln dust and cement kiln dust may be added to DSA to account for up to 50% of the fines passing the #200 sieve. The amount of particles passing the #200 sieve shall be determined using the washing procedures specified in PTM No. 100.
Size:
The required amounts and allowed ranges, determined by % weight, for various size particles are shown on page 1 of the certification.
LA Abrasion:
The acceptable limit as measured by weight loss is “less than 40% loss”. Los Angeles Abrasion test, AASHTO T-96 [ASTM C 131] shall be used to determine this property. Existing data obtained from tests made for and approved by PennDOT will be accepted.
pH:
Aggregate must be in the range of pH 6 to pH 12.45 as measured by EPA 9045C.
Optimum Moisture:
Material is to be delivered and placed at optimum moisture content +/- 1% as determined for that particular source. The optimum percentage moisture is to be determined using Proctor Test ASTM D698, procedure C, Standard.
Plasticity Index:
Material must not exceed Plasticity Index (PI) rating of 6. The laboratory test required for these results is the ASTM D4318 – Standard Test Method for Liquid Limit, Plastic Limit, and Plasticity Index of Soils.
Transportation:
Tarps are to be used to cover 100% of the load’s exposed surface from the time of loading until immediately before dumping. This requirement includes standing time waiting to dump.
Sheet1
File details come from the government source that posted it. Updated .