AMENDMENT OF SOLICITATION/ MODIFICATION OF CONTRACT
1. CONTRACT ID CODE
PAGE OF PAGES
2. AMENDMENT/MODIFICATION NO.
3. EFFECTIVE DATE
4. REQUISITION/PURCHASE REQ. NO.
5. PROJECT NO. (If applicable)
| AMENDMENT #3 |
| 04/16/2018 |
6. ISSUED BY
CODE
7. ADMINISTERED BY (If other than Item 6)
See Block 6
8. NAME AND ADDRESS OF CONTRACTOR (No., street, country, State and Zip Code)
(x)
9A. AMENDMENT OF SOLICITATION NO.
FN1447-18
X
9B. DATED (SEE ITEM 11)
02/ x
03/26/2018
10A. MODIFICATION OF CONTRACT/ORDER NO.
10B. DATED (SEE ITEM 13)
FACILITY CODE
11. THIS ITEM ONLY APPLIES TO AMENDMENT OF SOLICITATIONS
The above numbered solicitation is amended as set forth in Item 14. The hour and the date specified for receipt of Offers is extended, is not extended.
Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods: (a) By completing items 8 and 15, and returning copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted; or (c) By separate letter or telegram which includes a reference to the solicitation and amendment number. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE
DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS,
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
(X)
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, Appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103 (b).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF :
D. OTHER (Specify type of modification and authority)
E. IMPORTANT : Contractor is not, x is required to sign this document and return 2 copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
COMMODITY: Panels Plywood, and Particleboard SEE ATTACHED
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
Tiffani Balestrini, Contract Specialist
15B. CONTRACTOR/OFFEROR
15C. DATE SIGNED
16B. UNITED STATES OF AMERICA
16C. DATE SIGNED
BY
(Signature of the person authorized to sign)
(Signature of contracting officer)
NSN 7540-01-152-8070
PREVIOUS EDITION UNUSABLE
30-105
STANDARD FORM 30 (REV. 10-83)
Prescribed by GSA
FAR(48 CFR) 53.243
This amendment corrects the specification for the following items:
Line 21 Old Description
PNL0275-CHERRY,3/4"X4'X10',A-1,7-PLY
DESCRIPTION:CHERRY/CHERRY
UNICOR PART NUMBER: PNL0275
GRADE:A-1
FACE/BACK:PLAIN SLICED BOOKMATCHED,CHERRY
VENEER THICKNESS:1/48"
NO VISIBLE GLUE LINES ACCEPTED
TOLERANCE:DIMENSIONS: (+/-) 1/32"
SQUARENESS:PANELS,DIAGONAL MEASURE,
LARGER THAN 48"X48" (+/-) 1/16"
SMALLER THAN 48"X48" (+/-) 1/16"
EACH SHIPMENT OF PANELS MUST BE
ACCOMPANIED BY A SIGNED CERTIFICATE OF
COMPLIANCE REFERENCING LABORATORY TEST
DATA FOR THAT SHIPMENT
ALL PANELS MUST CONFORM TO ALL
REQUIREMENTS ESTABLISHED IN HARDWOOD
PLYWOOD AND VENEER ASSOCIATION INTERIM
STANDARD HP-1 1994
CORE: PARTICLEBOARD WITH THE FOLLOWING
AVERAGE PROPERTIES BASED ON 3/4" BOARD
TO ANSI STANDARD 208.1
SCREW HOLDING, FACE- 300 LB.
SCREW HOLDING, EDGE- 250 LB.
AVERAGE DENSITY SHALL NOT BE MORE THAN
10% BELOW THE NOMINAL DENSITY AS STATED
BY THE MANUFACTURER
M.O.E.- 326300 PSI
M.O.R.- 2103 PSI
INTERNAL BOND STRENGTH- 80 PSI
THE USE OF PARTICLEBOARD
WHICH DOES NOT MEET THE
ABOVE SPECIFICATION IS NOT ACCEPTABLE
FOR USE IN OUR PRODUCTS
REJECTED PANELS TO
BE REMOVED AT SUPPLIER'S EXPENSE AND REPLACED AT BUYER'S REQUEST
DELIVERIES WILL NOT BE ACCEPTED WITHOUT A SIGNED CERTIFICATE OF
CONFORMANCE
NOT MEETING SPECIFICATIONS ARE SUBJECT TO REJECTION
New Description
PNL0275-
CHERRY,3/4"X4'X10',A-1,7-PLY
DESCRIPTION:CHERRY/CHERRY
UNICOR PART NUMBER: PNL0275
GRADE:A-1
FACE/BACK:PLAIN SLICED BOOKMATCHED,CHERRY
VENEER THICKNESS:1/48"
NO VISIBLE GLUE LINES ACCEPTED
TOLERANCE:DIMENSIONS: (+/-) 1/32"
SQUARENESS:PANELS,DIAGONAL MEASURE,
LARGER THAN 48"X48" (+/-) 1/16"
SMALLER THAN 48"X48" (+/-) 1/16"
EACH SHIPMENT OF PANELS MUST BE
ACCOMPANIED BY A SIGNED CERTIFICATE OF
COMPLIANCE REFERENCING LABORATORY TEST
DATA FOR THAT SHIPMENT
ALL PANELS MUST CONFORM TO ALL
REQUIREMENTS ESTABLISHED IN HARDWOOD
PLYWOOD AND VENEER ASSOCIATION INTERIM
STANDARD HP-1 1994
THE FOLLOWING Plywood
AVERAGE PROPERTIES BASED ON 3/4" BOARD
TO ANSI STANDARD 208.1
SCREW HOLDING, FACE- 300 LB.
SCREW HOLDING, EDGE- 250 LB.
AVERAGE DENSITY SHALL NOT BE MORE THAN
10% BELOW THE NOMINAL DENSITY AS STATED
BY THE MANUFACTURER
M.O.E.- 326300 PSI
M.O.R.- 2103 PSI
INTERNAL BOND STRENGTH- 80 PSI
THE USE OF Plywood
WHICH DOES NOT MEET THE
ABOVE SPECIFICATION IS NOT ACCEPTABLE
FOR USE IN OUR PRODUCTS
REJECTED PANELS TO
BE REMOVED AT SUPPLIER'S EXPENSE AND REPLACED AT BUYER'S REQUEST
DELIVERIES WILL NOT BE ACCEPTED WITHOUT A SIGNED CERTIFICATE OF
CONFORMANCE
NOT MEETING SPECIFICATIONS ARE SUBJECT TO REJECTION
Line 23 PNL0274 Old description:
CHERRY,3/4"X4'X8',A-1,7-PLY
DESCRIPTION:CHERRY/CHERRY
UNICOR PART NUMBER: PNL0274
GRADE:A-1
FACE/BACK:PLAIN SLICED BOOKMATCHED,CHERRY
VENEER THICKNESS:1/48"
NO VISIBLE GLUE LINES ACCEPTED
TOLERANCE:DIMENSIONS: (+/-) 1/32"
SQUARENESS:PANELS,DIAGONAL MEASURE,
LARGER THAN 48"X48" (+/-) 1/16"
SMALLER THAN 48"X48" (+/-) 1/16"
EACH SHIPMENT OF PANELS MUST BE
ACCOMPANIED BY A SIGNED CERTIFICATE OF
COMPLIANCE REFERENCING LABORATORY TEST
DATA FOR THAT SHIPMENT
ALL PANELS MUST CONFORM TO ALL
REQUIREMENTS ESTABLISHED IN HARDWOOD
PLYWOOD AND VENEER ASSOCIATION INTERIM
STANDARD HP-1 1994
CORE: PARTICLEBOARD WITH THE FOLLOWING
AVERAGE PROPERTIES BASED ON 3/4" BOARD
TO ANSI STANDARD 208.1
SCREW HOLDING, FACE- 300 LB.
SCREW HOLDING, EDGE- 250 LB.
AVERAGE DENSITY SHALL NOT BE MORE THAN
10% BELOW THE NOMINAL DENSITY AS STATED
BY THE MANUFACTURER
M.O.E.- 326300 PSI
M.O.R.- 2103 PSI
INTERNAL BOND STRENGTH- 80 PSI
THE USE OF PARTICLEBOARD
WHICH DOES NOT MEET THE
ABOVE SPECIFICATION IS NOT ACCEPTABLE
FOR USE IN OUR PRODUCTS
REJECTED PANELS TO
BE REMOVED AT SUPPLIER'S EXPENSE AND REPLACED AT BUYER'S REQUEST
DELIVERIES WILL NOT BE ACCEPTED WITHOUT A SIGNED CERTIFICATE OF
CONFORMANCE
NOT MEETING SPECIFICATIONS ARE SUBJECT TO REJECTION
New Description PNL0274
CHERRY,3/4"X4'X8',A-1,7-PLY
DESCRIPTION:CHERRY/CHERRY
UNICOR PART NUMBER: PNL0274
GRADE:A-1
FACE/BACK:PLAIN SLICED BOOKMATCHED,CHERRY
VENEER THICKNESS:1/48"
NO VISIBLE GLUE LINES ACCEPTED
TOLERANCE:DIMENSIONS: (+/-) 1/32"
SQUARENESS:PANELS,DIAGONAL MEASURE,
LARGER THAN 48"X48" (+/-) 1/16"
SMALLER THAN 48"X48" (+/-) 1/16"
EACH SHIPMENT OF PANELS MUST BE
ACCOMPANIED BY A SIGNED CERTIFICATE OF
COMPLIANCE REFERENCING LABORATORY TEST
DATA FOR THAT SHIPMENT
ALL PANELS MUST CONFORM TO ALL
REQUIREMENTS ESTABLISHED IN HARDWOOD
PLYWOOD AND VENEER ASSOCIATION INTERIM
STANDARD HP-1 1994
CORE: Plywood WITH THE FOLLOWING
AVERAGE PROPERTIES BASED ON 3/4" BOARD
TO ANSI STANDARD 208.1
SCREW HOLDING, FACE- 300 LB.
SCREW HOLDING, EDGE- 250 LB.
AVERAGE DENSITY SHALL NOT BE MORE THAN
10% BELOW THE NOMINAL DENSITY AS STATED
BY THE MANUFACTURER
M.O.E.- 326300 PSI
M.O.R.- 2103 PSI
INTERNAL BOND STRENGTH- 80 PSI
THE USE OF Plywood
WHICH DOES NOT MEET THE
ABOVE SPECIFICATION IS NOT ACCEPTABLE
FOR USE IN OUR PRODUCTS
REJECTED PANELS TO
BE REMOVED AT SUPPLIER'S EXPENSE AND REPLACED AT BUYER'S REQUEST
DELIVERIES WILL NOT BE ACCEPTED WITHOUT A SIGNED CERTIFICATE OF
CONFORMANCE
NOT MEETING SPECIFICATIONS ARE SUBJECT TO REJECTION
Line 27 PNL2839 Old description
WALNUT/WALNUT,3/4"X4'X8',A/C,9-PLY
WALNUT/WALNUT,3/4"X4'X8',A/C,9-PLY
UNICOR PART NUMBER: PNL2839
GRADE:A/C VENEER SIZE:3/4"X4'X8'
J-GRADE INNER PLY BLACK WALNUT VENEER
MANUFACTURED ACCORDING TO HPMA HP-1 1992
,ANSI A208, 2-1994 AND FEDERAL
SPECIFICATION AA-T-00633
TOLERANCE:DIMENSIONS: (+/-) 1/32"
SQUARENESS:PANELS,DIAGONAL MEASURE,
LARGER THAN 48"X48" (+/-) 1/16"
SMALLER THAN 48"X48" (+/-) 1/16"
EACH SHIPMENT OF PANELS MUST BE
ACCOMPANIED BY A SIGNED CERTIFICATE OF
COMPLIANCE REFERENCING LABORATORY TEST
DATA FOR THAT SHIPMENT
ALL PANELS MUST CONFORM TO ALL
REQUIREMENTS ESTABLISHED IN HARDWOOD
PLYWOOD AND VENEER ASSOCIATION INTERIM
STANDARD HP-1 1994
CORE: Plywood WITH THE FOLLOWING
AVERAGE PROPERTIES BASED ON 3/4" BOARD
TO ANSI STANDARD 208.1
SCREW HOLDING, FACE- 300 LB.
SCREW HOLDING, EDGE- 250 LB.
AVERAGE DENSITY SHALL NOT BE MORE THAN
10% BELOW THE NOMINAL DENSITY AS STATED
BY THE MANUFACTURER
M.O.E.- 326300 PSI
M.O.R.- 2103 PSI
INTERNAL BOND STRENGTH- 80 PSI
THE USE OF Plywood
WHICH DOES NOT MEET THE
ABOVE SPECIFICATION IS NOT ACCEPTABLE
FOR USE IN OUR PRODUCTS
REJECTED PANELS TO
BE REMOVED AT SUPPLIER'S EXPENSE AND REPLACED AT BUYER'S REQUEST
DELIVERIES WILL NOT BE ACCEPTED WITHOUT A SIGNED CERTIFICATE OF
CONFORMANCE
NOT MEETING SPECIFICATIONS ARE SUBJECT TO REJECTION
Line 28 PNL2875 Old description
WALNUT/WALNUT,3/4"X8'X4'CROSS-GRAIN
WALNUT/WALNUT,3/4"X8'X4'CROSS-GRAIN
A/C,9 PLY GRADE:A/C VENEER SIZE:3/4"X8'X4 CROSS GRAIN,
J-GRADE' INNER PLY BLACK WALNUT VENEER
UNICOR PART NUMBER: PNL2875
MANUFACTURED ACCORDING TO HPMA HP-1 1992
,ANSI A208, 2-1994 AND FEDERAL
SPECIFICATION AA-T-00633
TOLERANCE:DIMENSIONS: (+/-) 1/32"
SQUARENESS:PANELS,DIAGONAL MEASURE,
LARGER THAN 48"X48" (+/-) 1/16"
SMALLER THAN 48"X48" (+/-) 1/16"
EACH SHIPMENT OF PANELS MUST BE
ACCOMPANIED BY A SIGNED CERTIFICATE OF
COMPLIANCE REFERENCING LABORATORY TEST
DATA FOR THAT SHIPMENT
ALL PANELS MUST CONFORM TO ALL
REQUIREMENTS ESTABLISHED IN HARDWOOD
PLYWOOD AND VENEER ASSOCIATION INTERIM
STANDARD HP-1 1994
CORE: PARTICLEBOARD WITH THE FOLLOWING
AVERAGE PROPERTIES BASED ON 3/4" BOARD
TO ANSI STANDARD 208.1
SCREW HOLDING, FACE- 300 LB.
SCREW HOLDING, EDGE- 250 LB.
AVERAGE DENSITY SHALL NOT BE MORE THAN
10% BELOW THE NOMINAL DENSITY AS STATED
BY THE MANUFACTURER
M.O.E.- 326300 PSI
M.O.R.- 2103 PSI
INTERNAL BOND STRENGTH- 80 PSI
THE USE OF PARTICLEBOARD
WHICH DOES NOT MEET THE
ABOVE SPECIFICATION IS NOT ACCEPTABLE
FOR USE IN OUR PRODUCTS
REJECTED PANELS TO
BE REMOVED AT SUPPLIER'S EXPENSE AND REPLACED AT BUYER'S REQUEST
DELIVERIES WILL NOT BE ACCEPTED WITHOUT A SIGNED CERTIFICATE OF
New description-PNL2875
WALNUT/WALNUT,3/4"X8'X4'CROSS-GRAIN
WALNUT/WALNUT,3/4"X8'X4'CROSS-GRAIN
A/C,9 PLY GRADE:A/C VENEER SIZE:3/4"X8'X4 CROSS GRAIN,
J-GRADE' INNER PLY BLACK WALNUT VENEER
UNICOR PART NUMBER: PNL2875
MANUFACTURED ACCORDING TO HPMA HP-1 1992
,ANSI A208, 2-1994 AND FEDERAL
SPECIFICATION AA-T-00633
TOLERANCE:DIMENSIONS: (+/-) 1/32"
SQUARENESS:PANELS,DIAGONAL MEASURE,
LARGER THAN 48"X48" (+/-) 1/16"
SMALLER THAN 48"X48" (+/-) 1/16"
EACH SHIPMENT OF PANELS MUST BE
ACCOMPANIED BY A SIGNED CERTIFICATE OF
COMPLIANCE REFERENCING LABORATORY TEST
DATA FOR THAT SHIPMENT
ALL PANELS MUST CONFORM TO ALL
REQUIREMENTS ESTABLISHED IN HARDWOOD
PLYWOOD AND VENEER ASSOCIATION INTERIM
STANDARD HP-1 1994
CORE: Plywood WITH THE FOLLOWING
AVERAGE PROPERTIES BASED ON 3/4" BOARD
TO ANSI STANDARD 208.1
SCREW HOLDING, FACE- 300 LB.
SCREW HOLDING, EDGE- 250 LB.
AVERAGE DENSITY SHALL NOT BE MORE THAN
10% BELOW THE NOMINAL DENSITY AS STATED
BY THE MANUFACTURER
M.O.E.- 326300 PSI
M.O.R.- 2103 PSI
INTERNAL BOND STRENGTH- 80 PSI
THE USE OF Plywood
WHICH DOES NOT MEET THE
ABOVE SPECIFICATION IS NOT ACCEPTABLE
FOR USE IN OUR PRODUCTS
REJECTED PANELS TO
BE REMOVED AT SUPPLIER'S EXPENSE AND REPLACED AT BUYER'S REQUEST
DELIVERIES WILL NOT BE ACCEPTED WITHOUT A SIGNED CERTIFICATE OF
Line 30 PNL5059
Old description
WALNUT/WALNUT,1-1/2"X4'X8',A/A,18-PLY
WALNUT/WALNUT,1-1/2"X4'X8',A/A,18-PLY
UNICOR PART NUMBER: PNL5059
GRADE:A/A VENEER SIZE:1-1/2"X4'X8'
J-GRADE INNER PLY BLACK WALNUT VENEER
MANUFACTURED ACCORDING TO HPMA HP-1 1992
,ANSI A208, 2-1994 AND FEDERAL
SPECIFICATION AA-T-00633
TOLERANCE:DIMENSIONS: (+/-) 1/32"
SQUARENESS:PANELS,DIAGONAL MEASURE,
LARGER THAN 48"X48" (+/-) 1/16"
SMALLER THAN 48"X48" (+/-) 1/16"
EACH SHIPMENT OF PANELS MUST BE
ACCOMPANIED BY A SIGNED CERTIFICATE OF
COMPLIANCE REFERENCING LABORATORY TEST
DATA FOR THAT SHIPMENT
ALL PANELS MUST CONFORM TO ALL
REQUIREMENTS ESTABLISHED IN HARDWOOD
PLYWOOD AND VENEER ASSOCIATION INTERIM
STANDARD HP-1 1994
CORE: PARTICLEBOARD WITH THE FOLLOWING
AVERAGE PROPERTIES BASED ON 3/4" BOARD
TO ANSI STANDARD 208.1
SCREW HOLDING, FACE- 300 LB.
SCREW HOLDING, EDGE- 250 LB.
AVERAGE DENSITY SHALL NOT BE MORE THAN
10% BELOW THE NOMINAL DENSITY AS STATED
BY THE MANUFACTURER
M.O.E.- 326300 PSI
M.O.R.- 2103 PSI
INTERNAL BOND STRENGTH- 80 PSI
THE USE OF PARTICLEBOARD
WHICH DOES NOT MEET THE
ABOVE SPECIFICATION IS NOT ACCEPTABLE
FOR USE IN OUR PRODUCTS
REJECTED PANELS TO BE REMOVED AT SUPPLIER'S EXPENSE AND REPLACED AT
BUYER'S REQUEST
DELIVERIES WILL NOT BE ACCEPTED WITHOUT A SIGNED CERTIFICATE OF
New Description PNL5059
WALNUT/WALNUT,1-1/2"X4'X8',A/A,18-PLY
WALNUT/WALNUT,1-1/2"X4'X8',A/A,18-PLY
UNICOR PART NUMBER: PNL5059
GRADE:A/A VENEER SIZE:1-1/2"X4'X8'
J-GRADE INNER PLY BLACK WALNUT VENEER
MANUFACTURED ACCORDING TO HPMA HP-1 1992
,ANSI A208, 2-1994 AND FEDERAL
SPECIFICATION AA-T-00633
TOLERANCE:DIMENSIONS: (+/-) 1/32"
SQUARENESS:PANELS,DIAGONAL MEASURE,
LARGER THAN 48"X48" (+/-) 1/16"
SMALLER THAN 48"X48" (+/-) 1/16"
EACH SHIPMENT OF PANELS MUST BE
ACCOMPANIED BY A SIGNED CERTIFICATE OF
COMPLIANCE REFERENCING LABORATORY TEST
DATA FOR THAT SHIPMENT
ALL PANELS MUST CONFORM TO ALL
REQUIREMENTS ESTABLISHED IN HARDWOOD
PLYWOOD AND VENEER ASSOCIATION INTERIM
STANDARD HP-1 1994
CORE: Plywood WITH THE FOLLOWING
AVERAGE PROPERTIES BASED ON 3/4" BOARD
TO ANSI STANDARD 208.1
SCREW HOLDING, FACE- 300 LB.
SCREW HOLDING, EDGE- 250 LB.
AVERAGE DENSITY SHALL NOT BE MORE THAN
10% BELOW THE NOMINAL DENSITY AS STATED
BY THE MANUFACTURER
M.O.E.- 326300 PSI
M.O.R.- 2103 PSI
INTERNAL BOND STRENGTH- 80 PSI
THE USE OF Plywood
WHICH DOES NOT MEET THE
ABOVE SPECIFICATION IS NOT ACCEPTABLE
FOR USE IN OUR PRODUCTS
REJECTED PANELS TO BE REMOVED AT SUPPLIER'S EXPENSE AND REPLACED AT
BUYER'S REQUEST
DELIVERIES WILL NOT BE ACCEPTED WITHOUT A SIGNED CERTIFICATE OF
Except as provided herein, all other terms and conditions remain unchanged.
File details come from the government source that posted it.