Fire_Hydrant_Maintenance_Form.pdf

PDF 78 KB Posted

Attached to
Fire Hydrant Inspection, Testing, and Maintenance Services (Bid Discount)
Solicitation number
26-P-00517
Issued by
Hillsborough County, Florida

About this file

This is a Fire Hydrant Maintenance Form used by the City of Tampa Wastewater Department to document the inspection and maintenance status of fire hydrants at municipal facilities. The form is designed to capture comprehensive data on approximately 32 fire hydrants located at the Howard F. Curren Advanced Wastewater Treatment Plant (AWTP) at 2700 Maritime Boulevard, Tampa, Florida. The maintenance form requires contractors to inspect and document the condition of multiple hydrant components including flanges, caps, gaskets, stems, nozzles, valves, and branch/auxiliary valves, along with operability assessments. Contractors must evaluate flange height above grade, paint condition, cap condition, stem thread integrity, valve operation difficulty, flushing capability, reflective markers, and hydrant identification tags. The form requires documentation of clearance around each hydrant (minimum 3 feet), leak locations, lubrication status, and time required to clear hydrants, with specific operational codes assigned based on maintenance findings.

The form serves as the primary documentation tool for the fire hydrant inspection, testing, and maintenance services procurement with a bid due date of September 14, 2026. Contractors must comply with all documentation requirements specified in the form and enter data into the Water Department's management system (MSS). The maintenance assessment must determine operability status and assign appropriate condition codes, discontinuing work on hydrants not cleared within five minutes. This sheltered-market procurement is designated exclusively for Small Local Business Enterprise (SLBE) certified vendors, with EBO (Economically Disadvantaged Business Enterprise) eligibility requirements specified in the solicitation package. The contract scope includes inspection, testing, certification, and maintenance services with compliance required to ADA requirements and OSHA safety standards as outlined in the procurement documents.

View the file

Other files

File Type Posted
Fire_Hydrant_Inspection,_Testing,_and_Maintenance_Services_(Bid_Discount).pdf PDF
Fire_Hydrant_Inspection,_Testing,_and_Maintenance_Services_(Bid_Discount).pdf PDF
EBO-26-P-00363-Sheltered-Market-Project-Details-SLBE1.pdf PDF
Fire_Hydrant_Maintenance_Form.pdf PDF
Tampa_Cloud_Hosting_Policy_ADA.pdf PDF
26-P-00363-Minimum-Certified-Contact-List-SLBE.xlsx XLSX spreadsheet
ADA_Requirements_.pdf PDF
Attachment_#1_-_Material_Specifications.pdf PDF
Fire_Flow_Test_Documentation_Sheet.pdf PDF
Fire_Hydrant_MAP2.pdf PDF
Material_Specifications.pdf PDF
Occupational_Safety_and_Health_Administration_SDS.pdf PDF
Tampa_Cloud_Hosting_Policy_ADA.pdf PDF
Attachment_#4_-_Fire_Hydrant_MAP2.pdf PDF
BID_RESPONSE_FOR_FIRE_HYDRANTS.docx DOCX document
DMI-30-Form-Payment-Package-or-Final-with_Invoices_SLBE_ADA.pdf PDF
Fire_Hydrant_Inspection_Tech_Specs_v1.docx DOCX document
Material_Specifications.pdf PDF
Occupational_Safety_and_Health_Administration_SDS.pdf PDF
ADA_Requirements_.pdf PDF
26-P-00363-EBO-Determination-Letter-SLBE.pdf PDF
Attachment_#2_-_Fire_Hydrant_Maintenance_Form.pdf PDF
Attachment_#3_-_Fire_Flow_Test_Documentation_Sheet.pdf PDF
Fire_Flow_Test_Documentation_Sheet.pdf PDF
Fire_Hydrant_MAP2.pdf PDF
DMI-30-Form-Payment-Package-or-Final-with_Invoices_SLBE_ADA.pdf PDF
Show all 26

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ATTACHMENT F

Hydrant No. Location:

Loc. #

Date Installed:

Flange Condition: OK Damaged

Flange Above Grade: Less than 2" Between 2" & 6" Over 6"

Paint Condition: Poor Fair Good

Hydrant Caps: Missing Condition: Good Damaged

Hydrant Cap Gaskets: Missing Condition: Good Damaged

Hydrant Condition: (Y/N)

Hydrant Condition: Flange Bonnet Nozzle

Operating Nut: Worn Good

Stem Condition: Good Fair Poor

Stem Threads: Cross Threaded (Y/N)

Nozzle Condition: Good Damaged

Nozzle Threads:

Hydrant Valve:

Hydrant Valve: Easy Difficult Impossiible

Branch/Auxiliary Valve: Easy Difficult Impossiible

Flushing:

Flushing:

Reflective Marker:

Hydrant ID Tag:

Hydrant Clearance:

Each Hyd. Maintained Gets Codes 469, 472, 464

Leak location: If bonnet leaks(328) If nozzle leaks(327)

Is there a minimum clearance of 3 feet around hydrant? (Y/N) If no (nnn)

Water Department Use Only

Entered into MSS By: Date Entered:

Maintenance By:

Date:

Fire Hydrant Maintenance Form

City Of Tampa

Wastewater Department

Hydrant clear in 5 Min (Y/N)

Installed (Y/N)

Installed (Y/N)

Time to Clear

If installed (nnn)

Marker Present (Y/N)

ID Tag Present (Y/N)

Cross Threaded (Y/N)

Does Valve Leak? (Y/N)

Is barrel damaged?

Lubricated (Y/N)

Does hydrant leak? (Y/N) If hyd. Damaged (nnn) If flange leaks(329)

Operability

If installed (455)

If cleared in under 5 min.(nnn)

If not cleared in 5 min.(nnn)

Operability

If hydrant not cleared in 5 minutes discontinue.

General Comments:

If impossible (04)

If Impossible (337)

Installed By:

If damaged (nnn)

Water Department Information

If cross threaded (nnn)

Contractor Shall Circle or Enter The Appropriate Response

Lubricated (Y/N)

Hydrant Manuf./Model:

If missing (nnn) If damaged (nnn)

If less than 2"(360) If over 6" (359)

If poor (nnn)

If yes (nnn)

If poor (nnn)

If damaged (nnn)

If cross threaded (nnn)

If worn (nnn)

If missing (356) If damaged (nnn)