This document appears to be a spreadsheet detailing fence repair and replacement requirements for the Dayton VA Medical Center. The related federal contract opportunity is a solicitation (Solicitation Number: 36C25024Q0975) for fence repairs at the Dayton VA Medical Center. The contract is set-aside for Service-Disabled Veteran Owned Small Businesses and the North American Industry Classification System code is 332323, Ornamental and Architectural Metal Work Manufacturing. The work includes replacing fence panels, posts, and gates across seven fence sections, with details provided for the specific repairs required in each section. The Produce Service Code for this procurement is Z2PZ Repair or Alteration of Other Non-Building Facilities.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25024Q0975 0001.docx | DOCX document | |
| VA Site Map.pdf | ||
| 36C25024Q0975.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| Fence section # | Replace/Repair Panel # | Replace/Repair Post | Description |
| Section #1 | Rod iron - Black | ||
| 68 panels | Replace picket on panel #60(1ea) | 95"w x 94"h with 3ea-1 3/4"x1 3/4" rail 1"x1" picket 2 3/4"x2 3/4" Post |
North Liscum Gate Powered Rod iron - Black
| Section #2 | Rod iron - Black | ||
| 139 Panels | Replace panel #113-115 (3ea) | Replace 3ea at panel 113-115 | 95"w x 94"h with 3ea-1 3/4"x1 3/4" rail 1"x1" picket 2 3/4"x2 3/4" Post |
South Liscum Gate Powered Rod iron - Black
| Section #3 | Rod iron - Black |
| 98 Panels | 95"w x 94"h with 3ea-1 3/4"x1 3/4" rail 1"x1" picket 2 3/4"x2 3/4" Post |
| Section #4 | Rod iron - Black |
| 69 Panels | 95"w x 94"h with 3ea-1 3/4"x1 3/4" rail 1"x1" picket 2 3/4"x2 3/4" Post |
Gate #1 and Gate #2 located at panel 4 and 69 Manual gates
Section #5 Chain link fencing
| Section #6 | Rod iron - Black | |
| Gate located at panel #51 | Replace 1ea. 3" post on latch side against column. Cut concrete sidewalk and install post in concrete footing | Manual with 3" posts |
| Section A (panels 1-16) | 95"w x 94"h with 3-1 3/4"x1 3/4" rail 1"x1" picket 2 3/4"x2 3/4" Post |
Section B (panels 17-50) Replace panel #31, 36, 40, 45 1)Replace post at panel #36 2)Post at panel #46 is loose at base 95"w x 64 3/4"h with 2ea - 1 3/4"x1 3/4" rail 1"x1" picket 2 3/4"x2 3/4" Post
| Section C (panels 51-54) | 95"w x 94"h with 3-1 3/4"x1 3/4" rail 1"x1" picket 2 3/4"x2 3/4" Post |
| Section between stone columns |
| Section D (panels 55-97) | Replace panel #64, 75, 90, 95 | 95"w x 64 3/4"h with 2ea - 1 3/4"x1 3/4" rail 1"x1" picket 2 3/4"x2 3/4" Post | |
| Swap out bad picket in panel #56(1ea), 63(4ea), 69(1ea), 89(3ea), | 1)Post at panel #89 needs to be replaced 2)Post at panel #97 needs reset in concrete | ||
| Gettysburg Gate | Powered Rod iron - Black |
| Section #7 | Rod iron - Black | |
| Section A (panels 1-12) | Replace panel #12 | 95"w x 64 3/4"h with 2ea - 1 3/4"x1 3/4" rail 1"x1" picket 2 3/4"x2 3/4" Post |
Section B (panels 13-27) 95"w x 94"h with 3ea-1 3/4"x1 3/4" rail 1"x1" picket 2 3/4"x2 3/4" Post