This document appears to be a spreadsheet detailing fence repair and replacement requirements for the Dayton VA Medical Center. The related federal contract opportunity is a solicitation (Solicitation Number: 36C25024Q0975) for fence repairs at the Dayton VA Medical Center. The contract is set-aside for Service-Disabled Veteran Owned Small Businesses and the North American Industry Classification System code is 332323, Ornamental and Architectural Metal Work Manufacturing. The work includes replacing fence panels, posts, and gates across seven fence sections, with details provided for the specific repairs required in each section. The Produce Service Code for this procurement is Z2PZ Repair or Alteration of Other Non-Building Facilities.

View the file

Other files

File Type Posted
36C25024Q0975 0001.docx DOCX document
VA Site Map.pdf PDF
36C25024Q0975.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1

Fence section #Replace/Repair Panel #Replace/Repair PostDescription
Section #1Rod iron - Black
68 panelsReplace picket on panel #60(1ea)95"w x 94"h with 3ea-1 3/4"x1 3/4" rail 1"x1" picket 2 3/4"x2 3/4" Post

North Liscum Gate Powered Rod iron - Black

Section #2Rod iron - Black
139 PanelsReplace panel #113-115 (3ea)Replace 3ea at panel 113-11595"w x 94"h with 3ea-1 3/4"x1 3/4" rail 1"x1" picket 2 3/4"x2 3/4" Post

South Liscum Gate Powered Rod iron - Black

Section #3Rod iron - Black
98 Panels95"w x 94"h with 3ea-1 3/4"x1 3/4" rail 1"x1" picket 2 3/4"x2 3/4" Post
Section #4Rod iron - Black
69 Panels95"w x 94"h with 3ea-1 3/4"x1 3/4" rail 1"x1" picket 2 3/4"x2 3/4" Post

Gate #1 and Gate #2 located at panel 4 and 69 Manual gates

Section #5 Chain link fencing

Section #6Rod iron - Black
Gate located at panel #51Replace 1ea. 3" post on latch side against column. Cut concrete sidewalk and install post in concrete footingManual with 3" posts
Section A (panels 1-16)95"w x 94"h with 3-1 3/4"x1 3/4" rail 1"x1" picket 2 3/4"x2 3/4" Post

Section B (panels 17-50) Replace panel #31, 36, 40, 45 1)Replace post at panel #36 2)Post at panel #46 is loose at base 95"w x 64 3/4"h with 2ea - 1 3/4"x1 3/4" rail 1"x1" picket 2 3/4"x2 3/4" Post

Section C (panels 51-54)95"w x 94"h with 3-1 3/4"x1 3/4" rail 1"x1" picket 2 3/4"x2 3/4" Post
Section between stone columns
Section D (panels 55-97)Replace panel #64, 75, 90, 9595"w x 64 3/4"h with 2ea - 1 3/4"x1 3/4" rail 1"x1" picket 2 3/4"x2 3/4" Post
Swap out bad picket in panel #56(1ea), 63(4ea), 69(1ea), 89(3ea),1)Post at panel #89 needs to be replaced 2)Post at panel #97 needs reset in concrete
Gettysburg GatePowered Rod iron - Black
Section #7Rod iron - Black
Section A (panels 1-12)Replace panel #1295"w x 64 3/4"h with 2ea - 1 3/4"x1 3/4" rail 1"x1" picket 2 3/4"x2 3/4" Post

Section B (panels 13-27) 95"w x 94"h with 3ea-1 3/4"x1 3/4" rail 1"x1" picket 2 3/4"x2 3/4" Post