Floor Plan
| Equipment pieces that require monitoring are listed in RED TEXT. Rooms without Red Text do not contain equipment that will require monitoring. | Building Dimensions are 339'-3" by 106'-8" (2nd Flr Total - 30,168 sq. ft. / 1st Flr. Total 33,915 sq. ft.) | ||||||||||||||||||||||||||||||||||||||
| MICRO | MICRO | STAIR No 1 | DEP. DIRECTOR | ||||||||||||||||||||||||||||||||||||
| MICROBIOLOGISTS | SUPV | SUPV | CONFERENCE ROOM | MICROBIOLOGISTS | MAIL/COPY | AS201 | A213 | ||||||||||||||||||||||||||||||||
| BREAK AREA | |||||||||||||||||||||||||||||||||||||||
| B255 | B251 | B247 | B243 | B241 | B201B | A263 | A259 | A255 | A251 | A247 | A211 | ||||||||||||||||||||||||||||
| STORAGE | |||||||||||||||||||||||||||||||||||||||
| SECRETARY | CONFERENCE | ||||||||||||||||||||||||||||||||||||||
| B202B CORRIDOR | A202B CORRIDOR | A213A | A212 | ||||||||||||||||||||||||||||||||||||
| B260 | B262 | B256 | B248 | B240 | COATS | B209 | A260 | A258 | A254 | A244 | A240 | A210 | |||||||||||||||||||||||||||
| COATS | |||||||||||||||||||||||||||||||||||||||
| MICRO | MICRO | MICROBIOLOGY | MICROBIOLOGY | MICROBIOLOGY | WOMEN | MICROBIOLOGY | VAULT | SALMONELLA | FOOD CHEMISTRY INSTRUMENT | FOOD CHEMISTRY | |||||||||||||||||||||||||||||
| CAN | CAN | INSTRUMENT | GENERAL | MEDIA PREP | DECON | SPECIATION | ROOM | EXTRACTION | |||||||||||||||||||||||||||||||
| SEAM | SEAM | LABORATORY | LABORATORY | LABORATORY | LABORATORY | LOBBY A201A | |||||||||||||||||||||||||||||||||
| 1 FREEZER | 1 REFRIGERATOR | 1 INCUBATOR | |||||||||||||||||||||||||||||||||||||
| 1 COMBO | 1 REFRIGERATOR | 2 COMBO REF/FRZ | 1 WATER BATH | SERVICE | 1 COMBO REF/FRZ | ||||||||||||||||||||||||||||||||||
| 1 INCUBATOR | ELEV | 5 WATER BATHS | ELEV | ||||||||||||||||||||||||||||||||||||
| #7 | #7a | #8 | #9 | #10 | #11 | ||||||||||||||||||||||||||||||||||
| AUTOCLAVES | W/I | LARGE | |||||||||||||||||||||||||||||||||||||
| REFRIG | ELEC | AUTOCLAVES | A209 | ||||||||||||||||||||||||||||||||||||
| B244 | B240A | B207 | A260A | CLOSET | |||||||||||||||||||||||||||||||||||
| #16 | |||||||||||||||||||||||||||||||||||||||
| B265 SERVICE CORRIDOR | 1 REFRIGERATOR | A265 SERVICE CORRIDOR | LIGHT WELL A200 | ||||||||||||||||||||||||||||||||||||
| B220 | B214A | B203B | |||||||||||||||||||||||||||||||||||||
| B264 | W/I | COMM | 1 COMBO REF/FRZ | 4 INC. | WASHER | ELEC | |||||||||||||||||||||||||||||||||
| 6 INC. | 9 WATER BATHS | 1 FREEZER | WALK | AUTOCLAVES | REFR | B200 | 1 INCUBATOR | DRYER | A208 | ||||||||||||||||||||||||||||||
| 1 REFRIGERATOR | 1 INC. | IN | FILES | JANITOR | 1 REFRIGERATOR | ||||||||||||||||||||||||||||||||||
| 2 COMBO REF/FRZ | INCUB | 1 REFRIGERATOR | **'Controller | MICROBIOLOGY | MICROBIOLOGY | MICRO | MICROBIOLOGY | FOOD CHEMISTRY | |||||||||||||||||||||||||||||||
| MICRO | MICROBIOLOGY | MICROBIOLOGY | 1 WI COOLER | B206 | B203 | RESEARCH | GENERAL | INCUB | GLASS WASH | EXTRACTION | |||||||||||||||||||||||||||||
| INCUB | INSTRUMENT | GENERAL | MICROBIOLOGY | LAB | LAB | ROOM | ROOM | LABORATORY | |||||||||||||||||||||||||||||||
| ROOM | LAB | LAB | MICRO | MEDIA PREP | MEN | 1 FREEZER | |||||||||||||||||||||||||||||||||
| INCUB | 1 REFRIGERATOR | ||||||||||||||||||||||||||||||||||||||
| ROOM | #17 | #6 | #6a | LOBBY A201B | |||||||||||||||||||||||||||||||||||
| #1 | #2 | #3 | #4 | #5 | |||||||||||||||||||||||||||||||||||
| 4 INC. | COPY | FAX | |||||||||||||||||||||||||||||||||||||
| B236 | B232 | B224 | B222 | B214 | B204 | A232 | A224 | A222 | A218 | A214 | |||||||||||||||||||||||||||||
| A207 | |||||||||||||||||||||||||||||||||||||||
| A204 | A202 | ||||||||||||||||||||||||||||||||||||||
| B202A CORRIDOR | A202A CORRIDOR | MICRO | |||||||||||||||||||||||||||||||||||||
| MICROBIOLOGY | RESOURCE | ||||||||||||||||||||||||||||||||||||||
| BS203 | B229 | B225 | B221 | B217 | B215 | INTERACTION AREA | AS202 | A235 | A233 | A229 | A225 | A221 | A205 | SECRETARY | ROOM | ||||||||||||||||||||||||
| B201A | |||||||||||||||||||||||||||||||||||||||
| MICROBIOLOGISTS | MICRO | EMPTY | LAB | MICROBIOLOGISTS | ANALYST OFFICES | FILE ROOM | A203 | ||||||||||||||||||||||||||||||||
| STAIR No 3 | SUPV | SUPPORT | NCTR | MICROBIOLOGY BRANCH | |||||||||||||||||||||||||||||||||||
| TECH | DIRECTOR | ||||||||||||||||||||||||||||||||||||||
| STAIR | |||||||||||||||||||||||||||||||||||||||
| No. 2 | |||||||||||||||||||||||||||||||||||||||
| SECOND FLOOR (01/21/11) | SECOND FLOOR (01/21/11) | ||||||||||||||||||||||||||||||||||||||
| SCALE = 10 FT | |||||||||||||||||||||||||||||||||||||||
| SHARED SUPPORT | MICROBIOLOGY | ||||||||||||||||||||||||||||||||||||||
| DIRECTOR'S AREA | |||||||||||||||||||||||||||||||||||||||
| NCTR | |||||||||||||||||||||||||||||||||||||||
| STAIR No. 1 | |||||||||||||||||||||||||||||||||||||||
| DIOXIN ANALYSTS | CONFERENCE | EMPTY | NCTR SUPV | NCTR ANALYSTS | MICROBIOLOGISTS | MICROBIOLOGISTS | |||||||||||||||||||||||||||||||||
| BREAK AREA | CONFERENCE | ||||||||||||||||||||||||||||||||||||||
| B155 | B151 | B147 | B143 | B141 | B101B | A163 | A159 | A155 | A151 | A147 | A111 | ROOM | |||||||||||||||||||||||||||
| STOR | |||||||||||||||||||||||||||||||||||||||
| B102B CORRIDOR | A113 | ||||||||||||||||||||||||||||||||||||||
| B160 | B156 | B152 | B148 | B144 | B140 | COATS | A160B | A156 | A148 | A144 | A142 | A140 | A110 | ||||||||||||||||||||||||||
| 2 WB | A160 | COATS | |||||||||||||||||||||||||||||||||||||
| 2 INC. | #18 | Incubators | FRZRS | ||||||||||||||||||||||||||||||||||||
| BSL | #12 | 4 INC. | 2 COMBO | ||||||||||||||||||||||||||||||||||||
| WOMEN | #18 | 2 FREEZERS | #13 | 3 ULT | |||||||||||||||||||||||||||||||||||
| DIOXIN | DIOXIN | DIOXIN | DIOXIN | DIOXIN | FOOD CHEM | 1 REFRIGERATOR | MICROBIOLOGY | NCTR | #14 | LOBBY | |||||||||||||||||||||||||||||
| EXTRACTION | EXTRACTION | EXTRACTION | EXTRACTION | EXTRACTION | SAMPLE PREP | 1 WB | GENERAL | A101A | A100 | ||||||||||||||||||||||||||||||
| SERVICE | B109 | 1 ULT | LABORATORY | LIGHT WELL | |||||||||||||||||||||||||||||||||||
| ELEV | 1 REF. | #18 | MICRO | NANO | ELEV | ||||||||||||||||||||||||||||||||||
| 2 INCUBATORS | W/I | ||||||||||||||||||||||||||||||||||||||
| #18 | AUTOCLAVE | 1 FREEZER | REFR | ||||||||||||||||||||||||||||||||||||
| ELEC | BSL | 3 WATER BATHS | #15 | A109 | |||||||||||||||||||||||||||||||||||
| B107 | A160C | A160A | 1 REFRIGERATOR | A142A | A140A | CLOSET | |||||||||||||||||||||||||||||||||
| MAIN | |||||||||||||||||||||||||||||||||||||||
| EXIT | B165 SERVICE CORRIDOR | A165 SERVICE CORRIDOR | LIGHT WELL | ENTRY | |||||||||||||||||||||||||||||||||||
| A100A | |||||||||||||||||||||||||||||||||||||||
| B103B | |||||||||||||||||||||||||||||||||||||||
| COMM | A108 | ||||||||||||||||||||||||||||||||||||||
| B164 | B100 | JANITOR | |||||||||||||||||||||||||||||||||||||
| FILES | |||||||||||||||||||||||||||||||||||||||
| B106 | ELEC | ||||||||||||||||||||||||||||||||||||||
| DIOXIN | DIOXIN | DIOXIN | DIOXIN | DIOXIN | B103 | NCTR | NCTR | GLASS | STORAGE | FOOD CHEMISTRY | FILTH | ||||||||||||||||||||||||||||
| EXTRACTION | EXTRACTION | EXTRACTION | EXTRACTION | EXTRACTION | WASH | PCR LAB | INSECTARY | ||||||||||||||||||||||||||||||||
| MEN | |||||||||||||||||||||||||||||||||||||||
| B126 | 1 REFRIGERATOR | LOBBY | |||||||||||||||||||||||||||||||||||||
| A101B | |||||||||||||||||||||||||||||||||||||||
| #19 | |||||||||||||||||||||||||||||||||||||||
| FAX | |||||||||||||||||||||||||||||||||||||||
| B134 | B128 | B122 | B118 | B114 | COPY | A130 | A126 | A122 | A120 | A116 | A114 | ||||||||||||||||||||||||||||
| B104 | A107 | ||||||||||||||||||||||||||||||||||||||
| A103 | |||||||||||||||||||||||||||||||||||||||
| B102A CORRIDOR | A102A CORRIDOR | ||||||||||||||||||||||||||||||||||||||
| BS103 | B125 | B121 | B117 | B115 | INTERACTION AREA | AS102 | A135 | A133 | A129 | A125 | A121 | A105 | |||||||||||||||||||||||||||
| NCTR ANALYSTS | |||||||||||||||||||||||||||||||||||||||
| QMS | EMPTY | IT TECHS | IT TECHS | IT | TRAINING | ||||||||||||||||||||||||||||||||||
| STAIR No. 3 | QA | DIOXIN ANALYSTS | IT | MANAGER | STORAGE | CLASSROOM | |||||||||||||||||||||||||||||||||
| FREEZER | LABORATORY | SPECIALIST | |||||||||||||||||||||||||||||||||||||
| STAIR | |||||||||||||||||||||||||||||||||||||||
| B180A | No 2 | ||||||||||||||||||||||||||||||||||||||
| B170A | |||||||||||||||||||||||||||||||||||||||
| RECEIVING | FIRST FLOOR (01/21/11) | FIRST FLOOR (01/21/11) | |||||||||||||||||||||||||||||||||||||
| SAMPLE | STORAGE | ||||||||||||||||||||||||||||||||||||||
| STORAGE | B161 | ||||||||||||||||||||||||||||||||||||||
| SHARED SUPPORT | |||||||||||||||||||||||||||||||||||||||
| B184 | SAMPLE | REFRIGERATOR | B163 | ||||||||||||||||||||||||||||||||||||
| CUST | JANITOR | FOOD CHEMISTRY | |||||||||||||||||||||||||||||||||||||
| DIOXIN | |||||||||||||||||||||||||||||||||||||||
| B182 | B180 | SAMPLE | |||||||||||||||||||||||||||||||||||||
| STORAGE | SAMPLE CUSTODIAN SUITE | ||||||||||||||||||||||||||||||||||||||
| B165 | |||||||||||||||||||||||||||||||||||||||
| RAMP | NCTR | ||||||||||||||||||||||||||||||||||||||
| B170 CORRIDOR | |||||||||||||||||||||||||||||||||||||||
| MICROBIOLOGY | |||||||||||||||||||||||||||||||||||||||
| LOADING | EQUIPMENT | ||||||||||||||||||||||||||||||||||||||
| DOCK | B171 | B169 | STORAGE | DIRECTOR'S AREA | |||||||||||||||||||||||||||||||||||
| B170 | SOLVENT | B167 | |||||||||||||||||||||||||||||||||||||
| STORAGE | WASTE | SCALE = 10 FT | |||||||||||||||||||||||||||||||||||||
| STORAGE | |||||||||||||||||||||||||||||||||||||||
| DOCK | TOOL ROOM | FIRE | |||||||||||||||||||||||||||||||||||||
| LEVELER | B172 | B168A | VALVE | ||||||||||||||||||||||||||||||||||||
| STORAGE | |||||||||||||||||||||||||||||||||||||||
| B168 |
&L&"Arial,Bold"&24&F, 01/21/2011, mws&C&"Arial,Bold"&24FDA ARKANSAS REGIONAL LAB, OCCUPANCY, FLOOR PLAN&R&"Arial,Bold"&24PAGE &P OF &N &L&12&F; &A; Printed on &D B101A B337
CLOSET
B339
CLOSET
B237
CLOSET
B239
CLOSET
B137
CLOSET
B139
CLOSET
B135
ELEC
Floor 3 Floor 2 Floor 1 Basement
Equipment List
| No. | Microbiology Tempsys sites | Air Sensor | ULT Frz Sensor | SS Sensor w/Glycol | Dual Probe Sensor w/Glycol | Micro Wire | |||
| Room Location | Instrument Count | Instrument Type | #42002 | #42003 | #42005 | 42021-DUAL-SS | 43002 | ||
| 1 | B236 | 6 | Incubators | 6 | 6 | ||||
| 2 | B232 | 9 | Waterbaths | 9 | |||||
| B232 | 1 | Refrigerator | 1 | 1 | |||||
| 3 | B224 | 1 | Freezer | 1 | 1 | ||||
| B224 | 1 | Incubators | 1 | 1 | |||||
| B224 | 2 | Refrig/Freezer | 2 | ||||||
| 4 | B222 | 4 | Incubators | 4 | 4 | ||||
| 5 | B214 | 1 | Refrigerator | 1 | 1 | ||||
| B214 | 1 | Walk-in cooler | 1 | 1 | |||||
| 6 | A224 | 1 | Refrig/Freezer | 1 | |||||
| A224 | 1 | Incubators | 1 | 1 | |||||
| A224 | 1 | Refrigerator | 1 | 1 | |||||
| 6a | A222 | 4 | Incubators | 4 | 4 | ||||
| 7 | B260 | 0 | |||||||
| 7a | B262 | 1 | Refrig/Freezer | 1 | |||||
| 8 | B256 | 1 | Refrigerator | 1 | 1 | ||||
| 9 | B248 | 1 | Freezer | 1 | 1 | ||||
| B248 | 2 | Refrig/Freezer | 2 | ||||||
| B248 | 1 | Incubators | 1 | 1 | |||||
| 10 | B240 | 1 | Refrigerator | 1 | 1 | ||||
| B240 | 1 | Waterbaths | 1 | ||||||
| 11 | A254 | 1 | Incubators | 1 | 1 | ||||
| A254 | 1 | Refrig/Freezer | 1 | ||||||
| A254 | 5 | Waterbaths | 5 | ||||||
| 12 | A148 | 2 | Incubators | 2 | 2 | ||||
| A148 | 1 | Freezer | 1 | 1 | |||||
| A148 | 3 | Waterbaths | 3 | ||||||
| A148 | 1 | Refrigerator | 1 | 1 | |||||
| 13 | A142 | 4 | Incubators | 4 | 4 | ||||
| 14 | A140 | 2 | Refrig/Freezer | 2 | |||||
| A140 | 3 | Ultra-low freezer | 3 | ||||||
| 15 | A142A | 1 | Refrigerator | 1 | 1 | ||||
| 16 | 2nd floor corridor | 1 | Refrigerator | 1 | 1 | ||||
| 17 | A232 | 1 | Freezer | 1 | 1 | ||||
| A232 | 1 | Refrigerator | 1 | 1 | |||||
| 18 | BSL2 A156 | 2 | Freezer | 2 | 2 | ||||
| BSL2 A156 | 1 | Refrigerator | 1 | 1 | |||||
| BSL2 A160B | 2 | Waterbaths | 2 | ||||||
| BSL2 A160B | 2 | Incubators | 2 | 2 | |||||
| BSL2 A160C | 1 | Waterbaths | 1 | 1 | |||||
| BSL2 A160C | 1 | Ultra-low freezer | 1 | ||||||
| BSL2 A160C | 1 | Refrigerator | 1 | 1 | |||||
| 19 | A116 | 1 | Refrigerator | 1 | 1 | ||||
| Total | 79 | 0 | 0 | 4 | 66 | 9 | 46 | ||
| 79 | |||||||||
| Infrastructure | |||||||||
| PC Computer: | Room B206 | ||||||||
| Repeater (1) | A224 | ||||||||
| Repeater (2) | B248 | ||||||||
| Repeater (3) | A148 |
Square Footage by Room
| Room Location | Sq. Footage |
| B236 | 263 |
| B232 | 560 |
| B224 | 1080 |
| B222 | 238 |
| B214 | 1080 |
| A224 | 1100 |
| A222 | 260 |
| B260 | 264 |
| B262 | 264 |
| B256 | 500 |
| B248 | 1080 |
| B240 | 1080 |
| A254 | 550 |
| A148 | 1134 |
| A142 | 118 |
| A140 | 138 |
| A142A | 104 |
| 2nd floor corridor | 1353 |
| A232 | 825 |
| BSL2 A156 | 410 |
| BSL2 A160B | 266 |
| BSL2 A160C | 145 |
| A116 | 546 |
Serial # of Equipment
| No. | Microbiology Temp sites | ||||||||
| Room Location | Instrument Count | Instrument Type | Make | Model | Brand | Serial # | FDA # | ||
| 1 | 1 | B236 | 1-Jan | Incubators | Forma | 3920 | Forma | 30166 | 5022433 |
| 2 | B236 | 2-Jan | Incubators | Precision | 30M | Thermo | -------- | 5099393 | |
| 3 | B236 | 3-Jan | Incubators | Forma | 3927 | Forma | 26065-433 | 5022085 | |
| 4 | B236 | 4-Jan | Incubators | Lab line | 702 | Labline | 516 | NA12050 | |
| 5 | B236 | 5-Jan | Incubators | Forma | 39185 | Forma | 39171-6 | NA12051 | |
| 6 | B236 | 6-Jan | Incubators | Lab line | 702 | Labline | 2131 | NA12052 | |
| 7 | 2 | B232 | 1-Feb | Waterbaths | Precision | 51221036 | Thermo | 602091720 | RT10971 |
| 8 | B232 | 2-Feb | Waterbaths | Precision | 2868 | Thermo | 207394-375 | ARL00190 | |
| 9 | B232 | 3-Feb | Waterbaths | Precision | 51221081 | Thermo | 602081596 | RT10969 | |
| 10 | B232 | 4-Feb | Waterbaths | Precision | 51221039 | Thermo | 602091799 | RT10973 | |
| 11 | B232 | 5-Feb | Waterbaths | Precision | 51221033 | Thermo | 602091794 | RT10975 | |
| 12 | B232 | 6-Feb | Waterbaths | Precision | 51221033 | Thermo | 602091804 | RT10976 | |
| 13 | B232 | 7-Feb | Waterbaths | Precision | 51221033 | Thermo | 602091802 | RT10968 | |
| 14 | B232 | 8-Feb | Waterbaths | Precision | 2866 | Thermo | 207981 | ARL00182 | |
| 15 | B232 | 9-Feb | Waterbaths | Precision | 2864 | Thermo | 201956 | NA12536 | |
| 16 | B232 | 10-Feb | Refrigerator | Revco | RLR6604A14 | Revco | W29R-615-484 XR | NA12540 | |
| 17 | 3 | B224 | 1-Mar | Freezer | Kenmore | ------- | Kenmore | 111760 | NA14972 |
| 18 | B224 | 2-Mar | Incubators | Gallenkamp | IOC400 | Gallenkamp | SG99/06/188 | NA14973 | |
| 19 | B224 | 3-Mar | Refrig/Freezer | Whirlpool | EL88TRRWQ | Whirlpool | U11942701 | ARL00523 | |
| 20 | B224 | 4-Mar | Refrig/Freezer | Whirlpool | ET14DC | Whirlpool | ------- | RT10260 | |
| 21 | 4 | B222 | 1-Apr | Incubators | Lab line | 702 | 2284 | 266 | NC21088 |
| 22 | B222 | 2-Apr | Incubators | Lab line | 600 | Lab Line | 1065 | NC21347 | |
| 23 | B222 | 3-Apr | Incubators | Precision | 30M | Thermo | 319313-580 | 5099392 | |
| 24 | B222 | 4-Apr | Incubators | Enviro Growth Chamber | ----- | EGC | 95056-01 | 5075367 | |
| 25 | 5 | B214 | 1-May | Refrigerator | Lab Research | RWS-69 | Lab Research | 1908915 | RT10441 |
| 26 | B214 | 2-May | Walk-in cooler | Jewett | BR1462 | Jewett | 63652-199 | 435000342 | |
| 27 | 6 | A224 | 1-Jun | Refrig/Freezer | Isotemp | 13986-106A | Fisher | 1521070766602 | NA12645 |
| 28 | A224 | 2-Jun | Incubators | Excella | E25 | New Brunswick | 900541757 | 5099323 | |
| 29 | A224 | 3-Jun | Refrigerator | Superior | ----- | Superior | 1381941 | NC21135 | |
| 30 | 6a | A222 | 6a-1 | Incubators | Enviro Growth Chamber | M25 | EGC | 3782-.7c-005A-120/208 | 5099365 |
| 31 | A222 | 6a-2 | Incubators | Precision | 30M | Thermo | 315475-247 | 5099360 | |
| 32 | A222 | 6a-3 | Incubators | Precision | 30M | Thermo | 317610-284 | 5099391 | |
| 33 | A222 | 6a-4 | Incubators | Precision | 30M | Thermo | 315475-248 | 5099361 | |
| 34 | 7a | B262 | 1-Jul | Refrig/Freezer | Revco | RCRF-192-A17 | Thermo | N25V-188089-NV | ARL00221 |
| 35 | 8 | B256 | 1-Aug | Refrigerator | Isotemp | C3-986-120 | Fisher | 201N0002 | RT10426 |
| 36 | 9 | B248 | 1-Sep | Freezer | Energuide | WF17-231-E | W.C. Wood | 002997237BA9402 | RT10769 |
| 37 | B248 | 2-Sep | Refrig/Freezer | Revco | RCRF-192-A17 | Thermo | O04-188203 | ARL00233 | |
| 38 | B248 | 3-Sep | Refrig/Freezer | White | WRT21BGAW2 | White | LA43915100 | NA14962 | |
| 39 | B248 | 4-Sep | Incubators | Excella | E-25 | New Brunswick | 80033/721 | 5099302 | |
| 40 | 10 | B240 | 1-Oct | Refrigerator | Jewett | BR-1461 | Jewett | 63651-199 | 435000339 |
| 41 | B240 | 2-Oct | Waterbaths | Precision | 51221036 | Thermo | 602091719 | RT10974 | |
| 42 | 11 | A254 | 1-Nov | Incubators | Forma | 3920 | Forma | 39964-51 | 5022432 |
| 43 | A254 | 2-Nov | Refrig/Freezer | GE | ----- | GE | TR524354 | NC21263 | |
| 44-45 | Dual Chamber | A254 | 3-Nov | Waterbaths | Labline | 18800 | Labline | 0199-0099 | RT11398 |
| 46 | A254 | 4-Nov | Waterbaths | Precision | 2870 | Thermo | 113061-1301 | ARL00630 | |
| 47 | A254 | 5-Nov | Waterbaths | Precision | 2837 | Thermo | 209247-1941 | ARL00421 | |
| 48 | 12 | A148 | 1-Dec | Incubators | Excella | E-25 | New Brunswick | 901044448 | 5099357 |
| 49 | A148 | 2-Dec | Incubators | Forma | 3920 | Forma | 39207-1 | NC21646 | |
| 50 | A148 | 3-Dec | Freezer | Thermo | 376-7A | Thermo | O11902O901100429 | ARL00378 | |
| 51 | A148 | 4-Dec | Waterbaths | Precision | 2866 | Thermo | 209518-478 | ARL00232 | |
| 52 | A148 | 5-Dec | Waterbaths | Precision | 2866 | Thermo | 208913-494 | ARL00398 | |
| 53 | A148 | 6-Dec | Waterbaths | Precision | 2862 | Thermo | 212534-543 | ARL00321 | |
| 54 | A148 | 7-Dec | Refrigerator | Isotemp | MR3OSS-GAEE-FS | Fisher | O1687661011110916 | ARL00636 | |
| 55 | 13 | A142 | 13-1 | Incubators | Precision | 3973 | Thermo | 310724-196 | 5099299 |
| 56 | A142 | 13-2 | Incubators | Precision | 3973 | Thermo | 310724-195 | 5099298 | |
| 57 | A142 | 13-3 | Incubators | Forma | 69697-1 | Forma | 3825 | NC21109 | |
| 58 | A142 | 13-4 | Incubators | Precision | 3973 | Thermo | 317610-285 | 5099394 | |
| 59 | 14 | A140 | 14-1 | Refrig/Freezer | White Westinghouse | ----- | White Westinghouse | RLF23913 | NC21197 |
| 60 | A140 | 14-2 | Refrig/Freezer | White | ----- | White | A43915100 | NC21084 | |
| 61 | A140 | 14-3 | Ultra-low freezer | Harris | ----- | Harris | R30L527834SL | RT10866 | |
| 62 | A140 | 14-4 | Ultra-low freezer | Isotemp | ----- | Fisher | N30M567075 | 5089173 | |
| 63 | A140 | 14-5 | Ultra-low freezer | Harris | ----- | Harris | R256335291-SG | RT10333 | |
| 64 | 15 | A142A | 15-1 | Refrigerator | Jewett | BR1458 | Jewett | 63628-199 | DCT435-000343 |
| 65 | 16 | 2nd floor corridor | 16-1 | Refrigerator | Isotemp Plus | 13-986-130 | Fisher | 210N0003 | 5089176 |
| 66 | 17 | A232 | 17-1 | Freezer | Isotemp | 13-986-148 | Fisher | 2017090216244 | ARL00019 |
| 67 | A232 | 17-2 | Refrigerator | Altair | ATSR23D6A | Altair | 13632645 | NA10444 | |
| 68 | 18 | BSL2 A156 | 18-1 | Freezer | Revco | UFP-2330A18 | Revco | X07N-101479-XN | NA14985 |
| 69 | BSL2 A156 | 18-2 | Freezer | Revco | UEN-2320A18 | Revco | X07N-1014678-XN | NA14986 | |
| 70 | BSL2 A156 | 18-3 | Refrigerator | Revco | REL-5004A20 | Revco | X07N-101481-XN | NA14984 | |
| 71 | BSL2 A160B | 18-4 | Waterbaths | Precision | 51221080 | Thermo | 602081116 | RT10972 | |
| 72 | BSL2 A160B | 18-5 | Waterbaths | Precision | ----- | Thermo | 602091798 | RT10977 | |
| 73 | BSL2 A160B | 18-6 | Incubators | Lab Line | 3920 | Lab Line | 39207-1 | NA12069 | |
| 74 | BSL2 A160B | 18-7 | Incubators | Lab Line | 3920 | Lab Line | 39207-1 | NA12068 | |
| 75 | BSL2 A160C | 18-8 | Waterbaths | Precision | 1221039 | Thermo | 602091800 | RT10970 | |
| 76 | BSL2 A160C | 18-9 | Ultra-low freezer | Revco | ULT-390-9-A31 | Revco | X06N-202958-XN | NA14982 | |
| 77 | BSL2 A160C | 18-10 | Refrigerator | Revco | REL 5004A20 | Revco | X07N-101480-XN | NA14987 | |
| 78 | 19 | A116 | 19-1 | Refrigerator | Frigidaire | FRU17B2JW20 | Frigidaire | WA10301639 | ARL00481 |