Statement of Work.pdf

PDF 777 KB Posted

Attached to
Adverse Events Monitoring Systems (AEMS)
Solicitation number
FDA-2026-136896
Issued by

About this file

This is a Statement of Work (SOW) for the FDA's Adverse Events Monitoring System (AEMS) consolidation and modernization initiative.

The FDA seeks contractor support to maintain and enhance the AEMS ecosystem, which consolidates multiple legacy adverse event reporting systems across all FDA Centers, Offices, and Programs (COPs). The scope encompasses seven major task areas: (1) Project Management; (2) COTS Vendor Support, Licenses, and Services; (3) Development, Modernization, and Enhancement; (4) Data Migration, Data Sharing, and System Integration; (5) Data Management; (6) Operations and Maintenance; and (7) User Training and Knowledge Management. Key deliverables include comprehensive platform implementation with unified case management, automated workflow routing, AI-based analytics and signal detection, autonomous data redaction, real-time data integration, and legacy system decommissioning support. The contractor must manage end-to-end data processing services across all centers, including medical coding using standardized vocabularies (MedDRA, VeDDRA), quality assurance programs achieving 95-100% accuracy for critical elements, and dictionary management. Operations and maintenance services require 99.9% system uptime, multi-tiered technical support with defined SLAs (critical issues resolved within 30 minutes), and regular training delivery. The contract type is Firm Fixed Price (FFP), and deliverables must comply with Section 508 accessibility standards and be submitted in Office 365 and Adobe Acrobat-compatible formats. The SOW covers processing of over 5 million annual adverse event reports across CDER, CBER, CDRH, HFP, CVM (drugs and food), CTP, and OCS, with specialized requirements for each center including medical device reporting under 21 CFR Part 803, vaccine adverse events, veterinary products, tobacco products, cosmetics, and human food and dietary supplement complaints.

View the file

Other files

File Type Posted
Notice of Intent_AEMS.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Adverse Events Monitoring Systems (AEMS)

FDA-2026-136896

STATEMENT OF WORK

1. BACKGROUND

The Food and Drug Administration (FDA) protects and advances public health through two core functions. First, the FDA ensures the safety, efficacy, and security of human and veterinary drugs, biological products, vaccines, medical devices, food and animal feed, dietary supplements, cosmetics, and radiation-emitting products. Second, the FDA accelerates innovations that make medicines more effective, safer, and more affordable, while equipping the public with accurate, science-based information to support informed decisions about FDA regulated products.

Across all FDA Centers, Offices, and Programs (COPs), FDA currently operates a fragmented and aging ecosystem of siloed systems for adverse event reporting, product problem tracking, whistleblower intake, and regulatory misconduct monitoring. These legacy systems — including the FDA Adverse Events Reporting System (FAERS), Tissues Adverse Reporting System (TARS), CTP Tobacco Database (TOB), Vaccine Adverse Event Reporting System (VAERS), Human Foods Complaint System (HFCS), electronic Medical Device Reporting (eMDR), the Center for Veterinary Medicine Adverse Drug Event Reporting System (CVM AERS), Complaint Management System (CMS), and the Center for Veterinary Medicine Pet and Livestock Food Early Warning and Surveillance System (PFEWSS) — collectively process over 5 million adverse event reports, product quality reports, and regulatory complaints annually, yet remain largely disconnected from one another, limiting FDA's ability to detect emerging signals and respond at the speed modern public health demands.

Figure 1 Figure 1 Consolidation Conceptual Architecture

At the center of this landscape, the FAERS II system — implemented in November 2021 — currently manages Adverse Event Reports (AERs) for CDER, OCS Cosmetics, and certain CBER products, interfacing with the Electronic Submissions Gateway (ESG), Safety Reporting Portal (SRP), and MedWatch Online. While FAERS II houses over 17 million case safety reports and supports more than 600 users, it represents only a fraction of FDA's broader reporting infrastructure and underscores the urgent need for a unified, intelligent, and scalable enterprise solution capable of transforming how FDA collects, analyzes, and acts on critical safety data across its entire portfolio.

This fragmented environment creates three (3) significant operational challenges: data silos that block cross-center safety signal detection, inconsistent data standards that drive inefficiencies and duplicative work, and legacy system limitations that prevent FDA from leveraging advanced AI/ML capabilities needed for modern surveillance and rapid response to emerging health threats.

FDA has recently (in 2026 refer to fig. 1.) implemented a unified Adverse Event Monitoring System (AEMS) to replace COPS legacy systems and modernize operations while maintaining compliance with regulatory frameworks, international standards (21 CFR Parts 314, 600, 1271, 803, 514, ICH E2B, VICH guidelines, etc. ) and congressional mandates for adverse events monitoring, with the consolidated platform enabling standardized data management, querying and sharing of reports across all COPs., comprehensive cross-product safety signal detection, analytics, reporting, automated regulatory compliance, and scalable infrastructure while preserving center-specific operational requirements across the COPs.

2. OBJECTIVE

The objective of this contract is to maintain and enhance the FDA's Adverse Event Monitoring System (AEMS) ecosystem through comprehensive contractor support services. This initiative advances FDA's comprehensive modernization of adverse event reporting, product quality assessments, product and regulatory complaints, and regulatory misconduct documentation across the complete spectrum of premarket and postmarket activities. The platform consolidates reporting and surveillance functions across all Centers, Offices, and Programs (COPs), replacing disparate legacy systems with an integrated, scalable infrastructure that enhances operational efficiency and regulatory oversight capabilities.

The successful contractor will deliver:

• Unified Platform Implementation and Support: A scalable, enterprise-wide system that consolidates multiple legacy platforms currently processing millions of individual case safety reports (ICSRs) or adverse event reports (AERs), product quality reports, whistleblower complaints, and regulatory misconduct cases annually.

• Standardized Operations with Center Flexibility: An integrated solution that maintains Center-specific operational workflows while establishing enterprise-wide data standards and reporting protocols across all FDA Centers, Offices, and Programs.

• Advanced Analytics and Signal Detection: Enhanced safety surveillance capabilities for all FDA regulated products cross center by incorporating artificial intelligence (AI), machine learning (ML) algorithms, and real-time data sharing and integration to improve detection of safety signals and emerging public health risks.

• Regulatory Compliance Optimization: Streamlined processes that ensure adherence to domestic and international regulatory requirements while reducing administrative burden and processing timelines.

• Comprehensive Public Health Infrastructure: A single, efficient monitoring system that strengthens FDA's ability to protect public health through improved data quality, faster response times, and enhanced regulatory decision-making capabilities.

The modernized AEMS will support FDA's mission-critical responsibility to monitor the safety and quality of regulated products across all commodity areas, including drugs, biologics, vaccines, medical devices, human food and dietary supplements, tobacco products, cosmetics, and veterinary food and medicines, ensuring comprehensive surveillance capabilities that protect both human and animal health.

2.1 PURPOSE

The Food and Drug Administration (FDA) seeks to maintain and enhance its Adverse Event Monitoring System (AEMS) ecosystem. This initiative supports FDA's comprehensive modernization of adverse event surveillance across all Centers, Offices, and Programs (COPs), replacing fragmented legacy systems with a unified, scalable platform that processes millions of Individual Case Safety Reports (ICSRs), product quality reports, product complaints, and regulatory misconduct complaints annually across both premarket and postmarket activities.

The modernized AEMS will deliver Center-specific operational capabilities while establishing enterprise-wide standardization for data processing, advanced analytics, signal detection, artificial intelligence implementation, and real-time data integration. This integrated approach creates a single, efficient, and compliant adverse event monitoring infrastructure that strengthens FDA's ability to detect safety signals, ensure regulatory compliance, and protect public health across all regulated products including drugs, biologics, medical devices, vaccines, human food, dietary supplements, tobacco products, cosmetics, and veterinary food and medicines.

The selected contractor(s) will deliver integrated COTS solutions that accommodate unique Center-specific operational workflows while implementing enterprise-wide data standards and reporting protocols. The solution will enhance safety signal detection capabilities, streamline regulatory compliance processes, and strengthen public health protection through advanced analytics, artificial intelligence algorithms, and real-time data integration across all FDA surveillance activities.

2.2 STAKEHOLDERS

The key stakeholders for the FDA Adverse Event Monitoring System (AEMS) are:

• CDER’s safety reviewers, consumer safety officers and other evaluators within the Office of New Drugs (OND), Office of Generic Drugs (OGD), Office of Surveillance and Epidemiology (OSE), Office of Biostatistics and Epidemiology (OBE), Office of Pharmaceutical Quality (OPQ) and Office of Compliance (OC) and Division of Information Disclosure and Policy (DIDP)

• CBER’s safety reviewers, consumer safety officers and other evaluators within the Office of Biostatistics and Pharmacovigilance (OBPV), Office of Compliance and Biologics Quality (OCBQ), Office of Therapeutic Products (OTP)/Division of Human Tissues (DHT), Division of Disclosure and Oversight Management (DDOM). The Center for Disease Control and Prevention (CDC) is also a stakeholder, owning the data collection and management services for vaccine adverse events.

• OII manages processes and connects systems or complaint follow-up across all FDA COPs

• Human Foods Program (HFP) subject matter experts that support intake, record management, review, and follow-up to respective voluntary and mandatory food (including infant formula) and dietary supplement complaint reporting programs

• CTP (Center for Tobacco Products) reviewers including subject matter experts within the Office of Science (OS) and Office of Compliance and Enforcement (OCE)

• CVM Food (Center for Veterinary Medicine) safety reviewers including Veterinary Medical Officers and Consumer Safety Officers within the Office of Surveillance and Compliance

• CVM Drugs (Center for Veterinary Medicine) safety reviewers (Veterinary Medical Officers) in the Office of Surveillance and Compliance and the Office of Minor Use and Minor Species are the primary users;

however, adverse event data and pharmacovigilance analyses may be shared with internal and external stakeholders.

• CDRH (Center for Devices and Radiological Health), Medical device reports serve multiple user groups within CDRH, each with distinct roles and responsibilities in the device safety ecosystem from Office of Product Evaluation and Quality, OPEQ.

o Additional CDRH Stakeholders: The MDR program involves collaboration with medical device manufacturers, importers, user facilities, healthcare professionals, and consumers. The Division of Surveillance Support (DSS) / Division of Submission Support (DSS) within CDRH serves as a key internal stakeholder for coding guidance and MDR issue resolution. The Office of Product Evaluation and Quality (OPEQ) provide product code assignments and coding feedback. The MedSun program network of user facilities constitutes an additional stakeholder group with specialized reporting requirements.

• OCS (Office of the Chief Scientist)/Office of Cosmetics and Colors (OCAC) consists of subject matter experts (SME) that support intake, safety review, Freedom of Information Act (FOIA) and records management of voluntary and mandatory cosmetic product adverse events and product complaints reporting programs.

3. SCOPE

The scope of the unified Adverse Event Monitoring System (AEMS) ecosystem (refer to figure 1.0) shall provide a comprehensive platform serving as the enterprise foundation for safety surveillance across all FDA Centers. The base platform must deliver but not limited to:

(a) Core case management (i.e., LSMV COTS Tool) functionality with multi-format international XML standards intake processing;

(b) Automated case workflow routing and comprehensive lifecycle management;

(c) AI-based data redaction with human-in-the-loop oversight and advanced disposition tracking that maintains data integrity throughout case processing workflows;

(d) Advanced AI-based analytics, reporting, and signal detection (data mining) capabilities;

(e) Integration with FDA-developed advanced analytics and visualization tools including InfoViP;

(f) QLIKSense-based AEMS Public Dashboard for real-time publication;

(g) Automated integration with OpenFDA for API-based data services;

(h) Support complete automated and manual (as needed) data management support includes coding, quality checks, validations, and redaction;

(i) ThinkTrends (document AI-based) integration for case digitization for initial data entry and routing; and

(j) Support for legacy system decommissioning and automated data archiving.

Additionally, the system must provide an accessible interface for tracking and monitoring system change requests and defects during development and operations, including estimated completion timelines and status updates.

3.1 CORE PLATFORM CAPABILITIES

The AEMS platform shall provide the following enterprise-wide capabilities that serve as the foundation for all center-specific operations:

1. Unified Intelligent Case Management and Workflow Orchestration: The AEMS platform provides adaptive case management capabilities that dynamically support standardized intake processes while maintaining Center-specific submission formats, operational procedures, and regulatory requirements.

a. The system must implement machine learning-driven workflow orchestration that automatically routes cases based on product classification, submission source, and regulatory context without manual intervention.

b. AI-powered case digitization shall convert diverse submission formats to standardized Center-specific XML schemas during processing, ensuring seamless data consistency and enterprise-wide interoperability.

2. Cognitive Advance Analytics, Reporting, and Predictive Signal Detection: The platform shall deliver next-generation analytical capabilities incorporating natural language processing, temporal pattern recognition, and machine learning-based signal detection methodologies that proactively identify emerging safety trends.

a. The system must provide technology-agnostic analytical frameworks enabling integration of specialized tools while maintaining unified interfaces and data standards.

b. Advanced analytical engines shall support both autonomous signal detection algorithms and collaborative human-machine analysis workflows, empowering reviewers with intelligent case evaluation and predictive safety assessment capabilities

3. Autonomous Redaction, Privacy Protection and Compliance Assurance: The system shall implement intelligent data sanitization capabilities that automatically identify, classify, and redact sensitive and personally identifiable information using advanced machine learning algorithms to ensure strict compliance with 21 CFR §§ 20.63 and 20.111(c)(3), FOIA exemption (b)(6), and FDA privacy guidance.

a. The solution shall provide seamless integration with existing workflows, support real-time and batch processing modes, minimize manual oversight through intelligent automation, enable selective human validation for complex cases, and maintain immutable audit trails while preserving essential clinical data integrity throughout the monitoring lifecycle

4. Unified Data Ecosystem and Real-Time Integration: The system shall establish a comprehensive data orchestration platform that enables seamless, secure connectivity across internal FDA systems and external regulatory data sources while maintaining stringent security and compliance protocols.

a. The integration architecture shall support real-time data streaming, intelligent batch processing, and event-driven response mechanisms that facilitate immediate safety monitoring and automated regulatory reporting across all organizational units

5. Enterprise Data Consolidation and Historical Preservation: The platform shall execute comprehensive legacy system modernization through intelligent data migration from disparate Center databases into the unified AEMS (LSMV) environment, establishing LSMV as the definitive System of Record for all FDA safety and product quality documentation.

a. This capability requires sophisticated data transformation engines that preserve historical context, maintain temporal accuracy, ensure seamless integration of legacy reports as historical entries, and utilize proven enterprise migration methodologies to guarantee data fidelity during the comprehensive system consolidation process.

6. System Decommissioning, Archival, and Transition: The contractor shall provide end-to-end support for the decommissioning, archival, and transition of all COPS, leveraging AI tools wherever feasible to ensure efficient, secure, and compliant system retirement with minimal operational disruption.

a. The contractor shall support the full lifecycle retirement of all Computerized Operations and Processing Systems (COPS), encompassing three core activity areas: system decommissioning, data and system archival, and transition support. Decommissioning activities include planning, pre-shutdown assessment, controlled shutdown execution, and formal post-decommissioning documentation. Archival activities require the secure preservation of all data and system artifacts in compliance with NARA, FDA records retention schedules, and FISMA standards, with emphasis on data integrity, standardized formats, and access-controlled storage. Transition support ensures continuity of operations through structured planning, stakeholder coordination, knowledge transfer, user training, and post-transition monitoring.

b. The use of Artificial Intelligence is strongly preferred across all task areas to enhance efficiency and accuracy. AI applications include automated data discovery and classification, intelligent retention schedule mapping, NLP-driven knowledge extraction, anomaly detection during data migration, and robotic process automation for repetitive tasks. All AI tools must comply with FDA governance policies and applicable federal AI guidelines and shall be documented in a contractor-maintained AI Tools and Methodology Registry. Key deliverables include Decommissioning Plans, Archival Plans, Transition Roadmaps, Knowledge Transfer Packages, and Post-Transition Monitoring Reports for each applicable COPS.

3.2 CENTER-SPECIFIC OPERATIONAL REQUIREMENTS AND DATA

MANAGEMENT SERVICES

1. CENTER FOR DRUG EVALUATION AND RESEARCH (CDER): CDER operations demand an advanced pharmacovigilance ecosystem that transcends traditional safety monitoring through intelligent integration with the InfoVIP platform architecture, requiring sophisticated capabilities including:

1.1. Adaptive safety signal detection utilizes machine learning algorithms to identify emerging safety patterns before they manifest as widespread adverse events, with particular emphasis on rare disease treatments and personalized medicine products across therapeutic biologics, complex generics, novel drug delivery systems, and emerging pharmaceutical technologies.

1.2. Integrated pre-market risk assessment that correlates investigational new drug (IND) safety data with real-world evidence from similar therapeutic classes, enabling proactive risk mitigation strategies during clinical development while maintaining seamless connectivity with clinical trial safety data systems.

1.3. Intelligent product quality analytics that synthesize manufacturing deviation reports, release data, and field complaint information to predict potential quality issues across the pharmaceutical supply chain through enhanced entity resolution algorithms specifically calibrated for pharmaceutical nomenclature, including brand/generic name mapping and international non-proprietary name standardization.

1.4. Regulatory lifecycle management provides end-to-end visibility from IND submission through post-market commitments with automated milestone tracking, contextual natural language processing trained on regulatory submission documents, and temporal-spatial analysis engines that correlate safety events with manufacturing lot distributions and geographic prescribing patterns.

1.5. Strategic data ecosystem connectivity encompassing bidirectional data flows with Structured Product Labeling repositories, Clinical Data Interchange Standards Consortium compliant trial safety databases, Electronic Common Technical Document submission platforms, and Pharmaceutical Quality System databases for integrated quality-safety correlation analysis, positioning CDER to anticipate and respond to emerging pharmaceutical safety challenges while maintaining regulatory excellence across an increasingly complex therapeutic landscape.

1.6. Multi-channel report processing and triage supporting mandatory industry submissions, voluntary consumer reports, and healthcare professional communications through standardized registration workflows that ensure appropriate case prioritization and regulatory timeline compliance across all submission pathways.

1.7. Advanced data capture and standardization include accurate transcription of paper-based and PDF report formats, automated optical character recognition validation, and systematic data normalization to ensure consistent information architecture across diverse reporting sources and formats.

1.8. Medical terminology standardization and coding utilizing current versions of Medical Dictionary for Regulatory Activities (MedDRA), World Health Organization Drug Dictionary (WHO-DD), and other FDA-approved controlled vocabularies to ensure semantic consistency and enable sophisticated signal detection analytics.

1.9. Comprehensive quality assurance frameworks implementing multi-tier verification protocols including automated data validation rules, expert medical review processes, and statistical quality control measures to maintain data integrity standards exceeding regulatory compliance requirements.

1.10. Integrated safety surveillance processing seamlessly transitions coded data into pharmacovigilance workflows, enabling real-time safety signal detection, trend analysis, and regulatory reporting while maintaining full audit trails and data provenance documentation for regulatory inspection readiness.

1.11. Scalable workflow management supporting variable report volumes with surge capacity capabilities, automated workload distribution, and performance monitoring to ensure consistent processing times and quality standards regardless of submission volume fluctuations or seasonal reporting patterns.

2. CENTER FOR BIOLOGICS EVALUATION AND RESEARCH (CBER): CBER operations require sophisticated safety surveillance capabilities that integrate seamlessly with existing analytics infrastructure including Enterprise Business Objects (EBO) and InfoVIP platforms to maintain comprehensive analytical capabilities across the center's diverse biological product portfolio. Requiring sophisticated capabilities including:

2.1. Multi-product post-market surveillance architecture supporting approved drugs, biological products including vaccines, medical devices, human cells/tissues/cellular and tissue-based products (HCT/Ps), and blood components through unified analytical frameworks that accommodate product-specific regulatory requirements and safety profiles

2.2. Advanced analytical capabilities and signal detection encompassing case-level detailed outputs in both line listing and regulatory form formats (MedWatch/VAERS-style), descriptive epidemiological aggregation with comprehensive query functionality across all system data fields, and statistical algorithms utilizing data mining techniques that operate across complete MedDRA hierarchical structures to identify emerging safety signals

2.3. Customizable query and reporting infrastructure providing text-based and field/codelist search capabilities, configurable safety oversight reports tailored to specific product categories, and comprehensive regulatory submission tracking with automated milestone management and compliance monitoring

2.4. Integrated data ecosystem connectivity maintaining bidirectional data flows with biological product labeling databases, clinical trial safety repositories, regulatory submission tracking platforms, and product quality monitoring systems to ensure comprehensive safety intelligence across the product lifecycle

2.5. VAERS -specific operational requirements preserving existing two-level "events-based" and "reports-based" hierarchical structures with associated analytic reports, maintaining all current data fields including device-related elements, supporting selected report period and cumulative data presentation within unified reports, and sustaining established analytic metrics including rank delta calculations and lot-based proportional reporting ratios (LPRR)

2.6. VAERS system integration and data harmonization ensuring seamless connectivity with CDC VAERS databases through automated data synchronization and reconciliation processes, maintaining vaccine-specific adverse event MedDRA coding terminologies, and supporting comprehensive lot tracking and investigation capabilities while preserving FDA-CDC data consistency

2.7. Dynamic system adaptability and user functionality enabling addition of new data elements and values as VAERS source data evolves or business requirements change, ensuring MedDRA version compliance with automated periodic updates, preserving user capabilities to create and modify shareable reports via email, and maintaining existing analytical drill-down functionalities from aggregate counts to detailed line listings across MedDRA hierarchical levels.

2.8. Specialized product surveillance workflows incorporating vaccine-specific coding requirements and terminologies, blood product safety monitoring protocols, HCT/P regulatory compliance tracking, and medical device adverse event processing with appropriate product-specific data fields and analytical approaches tailored to each regulatory pathway.

2.9. HCT/P Tissue-Specific Real-Time Processing: CBER users can initiate data entry for a case immediately upon its arrival at FDA, enabling near-instantaneous access for all Tissue Safety Team (TST) members.

2.9.1. Collaborative Workspace: The system shall provide a shared workspace accessible to multiple CBER HCT/P stakeholders, supporting concurrent data entry and case investigation tracking.

The workspace must include integrated functionality to generate, track, and archive communications between CBER HCT/P reviewers and HCT/P manufacturers, reporting clinicians, facilities, and patients.

2.9.2. Simultaneous Use: The system shall support concurrent user sessions, allowing multiple users to view, enter, and save data within reports at the same time without conflict or data loss.

2.9.3. Attachment of Investigation Records: Users shall be able to attach relevant case investigation records — including MedWatch reports, culture results, tissue bank processing records, and donor records — directly to individual cases. Attached records shall be readily accessible from any case view.

2.9.4. Specialized Custom Data Recording: The system shall support specialized, customizable data entry and management for HCT/P-specific fields, including but not limited to: HCT/P product type, investigation status, donor information, donor testing results, organism identification, and case assessment.

2.9.5. Data Query and Analysis: The system shall provide a fully customizable ad-hoc query interface across all HCT/P fields, including TST-entered fields, as well as pre-programmed standardized queries and reports. Analytical capabilities shall support querying on any HCT/P field as a parameter and allow all HCT/P-related fields to be included in data outputs.

2.9.6. Integration: The system shall integrate with tissue establishment databases and relevant inspection systems to support seamless data exchange and regulatory oversight.

2.9.7. Blood and Blood Component-Specific Requirements for Product and Processing Code Capture: The system shall support capture of blood product types and processing codes in an ISBT-128 compliant format, along with functionality for blood donor tracking and recording of adverse events (AEs) related to blood and plasma donation.

2.9.8. Data Entry and Data Management Services for Vaccine Adverse Event Data Ingestion:

The Centers for Disease Control and Prevention (CDC) retain ownership of vaccine adverse event data management services, encompassing intake, data collection, triage, case classification, medical coding (MedDRA), and processing. FDA functions as a downstream data consumer, receiving finalized datasets for regulatory review. The consolidated AEMS shall ingest CDC-coded data seamlessly, without modification, unless alterations are explicitly requested by the relevant business owners.

2.9.9. Operational Resilience and Surge Capacity: The system shall demonstrate operational resilience and the capacity to process elevated adverse events reporting volumes during declared public health emergencies, including pandemics and other public health crises.

2.9.10. End-to-End Data Management for All Report Types: For all report types, contractors should provide comprehensive end-to-end data management services, including registration and triage support, safety surveillance processing, data standardization through medical coding and dictionary management, and robust quality assurance programs.

2.9.11. Processing of Mandatory and Voluntary Reports: Contractor responsibilities shall encompass processing both mandatory industry submissions and voluntary reports submitted by consumers and healthcare professionals, including accurate data entry of paper and PDF-based reports.

2.9.12. Medical Coding and Quality Control: Contractors shall apply standardized medical vocabularies — including MedDRA — for coding and shall implement quality control verification processes to ensure data integrity and regulatory compliance throughout the data lifecycle.

3. CENTER FOR DEVICES AND RADIOLOGICAL HEALTH (CDRH): CDRH requires a secure, multi-channel medical device reporting system with automated validation, UDI/GUDID integration, and specialized workflows — supported by contractor data entry and quality management services — to ensure timely, accurate, and compliant processing of MDR adverse event reports in accordance with 21 CFR Part 803 and related statutory authorities, requiring sophisticated capabilities including:

3.1. Multi-Channel Report Intake: The system must process MDR submissions from multiple input channels, including XML, PDF, email, and fax, accommodating the diverse submission methods used by device manufacturers, importers, and user facilities.

3.2. Five-Stage Sequential Workflow: The system shall support a defined core workflow consisting of five sequential stages — Data Entry, Coding, Redaction, Evaluation Ready, and Data Correction — with automated progression and quality control checkpoints between stages.

3.3. Automated Duplicate Detection: The system shall employ automated duplicate detection using device identifiers to prevent redundant records and maintain database integrity across the MDR reporting pipeline.

3.4. Device and Facility Validation (UDI/GUDID, FEI, and CMS): The system shall integrate with the Unique Device Identifier (UDI) and Global Unique Device Identification Database (GUDID) for real-time device identification and validation during data entry and processing. The system shall also perform Facility Establishment Identifier (FEI) and user facility verification as a mandatory data integrity checkpoint during report intake and processing and shall perform monthly synchronization with OII CMS data to maintain alignment with facility and provider information.

3.5. XML Validation and JSON Output: The system shall perform XML schema validation for all electronically submitted MDR reports to ensure structural and regulatory compliance prior to processing. The system shall additionally generate JSON-formatted outputs to support downstream analytics and reporting functions specific to CDRH operations.

3.6. Code Blue Flagging and Procedure Compliance: The system shall include specialized functionality to flag critical device events using a "Code Blue" designation, triggering expedited review and processing workflows. Contractors shall follow established Code Blue procedures for critical MDR reports, ensuring expedited handling and escalation consistent with CDRH protocols.

3.7. Adverse Event Correlation (Recalls and Regulatory Submissions): The system shall support correlation and tracking of adverse event reports against active device recalls, enabling CDRH reviewers to identify potential safety signals linked to recalled products. The system shall also provide functionality to correlate adverse event reports with relevant regulatory submissions, supporting comprehensive device safety oversight.

3.8. Cybersecurity Event Reporting: The system shall include specialized capabilities to capture and manage adverse event reports related to cybersecurity incidents involving connected medical devices.

3.9. User Roles and Access Controls: The system architecture shall support a minimum of three distinct user roles with role-appropriate access controls to maintain workflow integrity and data security.

3.10. Weekly Product Code Updates: The system shall support and incorporate weekly updates to device product codes to ensure coding accuracy and currency.

3.11. User Facility Reporting Compliance Monitoring: The system shall include functionality to monitor and flag user facility reporting compliance, supporting CDRH's oversight responsibilities under applicable regulations.

3.12. Regulatory Authority and Governing Standards: Contractor data entry and management services for medical device reports shall be performed in accordance with 21 CFR Part 803, the Safe Medical Devices Act of 1990 (SMDA) and its 1992 Amendment, and Section 519 of the Federal Food, Drug, and Cosmetic (FD&C) Act.

3.13. MDR Data Entry and Electronic Submission Processing: Contractors shall receive and enter MDR adverse event data into FDA-approved information systems, including processing electronic MDR submissions through designated FDA systems, in adherence to established SOPs.

The LSMV system serves as a centralized electronic submission platform supporting both manual data entry and automated processing.

3.14. Device-Incident Report Coding: Contractors shall code device-incident reports using appropriate product, device, and health effect codes in accordance with FDA coding guidelines and CDRH-specific requirements.

3.15. Scanning, Redaction, and Document Control: Contractors shall perform scanning and document control of paper MDR reports and shall create and maintain redacted copies of data in compliance with applicable privacy and regulatory requirements. Contractors shall maintain 95% scanning accuracy with complete document tracking and full compliance with redaction requirements across all scanned MDR records. Approximately 3,000 documents are scanned per month in batches of 15–20, processed through the Image2000+ application, converted to PDF, and saved in the FDA content management database.

3.16. Submitter Coordination and Error Correction: Contractors shall contact MDR submitters as needed to coordinate report resolution and correct data entry errors, ensuring accuracy and completeness of submitted information.

3.17. Telecommunications and Correspondence Management: Contractors shall manage the CDRH/MDR program phone line, responding to approximately 54 calls per month (approximately 20 voluntary, 8 data problem, 7 miscellaneous, and 15 referral calls). Calls must be answered between 8:30 a.m. and 5:00 p.m. EST, Monday through Friday, excluding Federal holidays, with 90% of calls answered within four rings. Contractors shall also manage MedWatch telecommunications and handle FDA-originated correspondence related to MDR activities.

3.18. Archiving and Courier Services: Contractors shall provide reliable archiving services and daily courier services with full security protocols to support physical document management and chain-of-custody requirements.

3.19. Standard Operating Procedures (SOPs) and Procedural Manuals: Contractors shall develop, maintain, and adhere to comprehensive SOPs covering all MDR-related activities to ensure consistent, compliant operations and support FDA regulatory oversight. Contractors shall also deliver annual updates to FDA procedural documents and manuals, including descriptions of newly implemented procedures, and shall maintain detailed logs and daily checklists documenting letters mailed and documents received, including MDR tracking information as specified by the FDA.

3.20. Data Accuracy and Quality Control Standards: Contractors shall maintain 95% accuracy for required data elements and 90% accuracy for non-required data elements, with continuous quality monitoring applied to electronically submitted reports at a 10% sampling rate to verify coding compliance and identify reporting discrepancies. Contractors shall achieve 95% coding accuracy using proper FDA product and adverse event codes, with ongoing quality control procedures to identify and remediate coding discrepancies.

3.21. Tiered Processing Timeframes by Report Type and Severity: MDR reports shall be processed according to severity-based and report-type-specific timeframes:

3.21.1. Manufacturer reports (~239,868 initial electronic and ~99,076 supplemental/follow-up per month; ~4 five-day reports per month): death reports within 3 business days, injury reports within 4 business days, malfunction reports within 15 business days.

3.21.2. Importer reports (~15,472 per month): death reports within 3 working days, injury reports within 4 working days, malfunction reports within 15 working days.

3.21.3. User facility initial reports (~8 per month) and MedSun reports (~605 per month):

processed per applicable timeframes; missing or incorrect CMS numbers must be corrected or auto generated.

3.21.4. User facility annual reports (Form 3419) (~30 per year, due January 1st): death reports not previously recorded in FDA adverse event systems must be entered within 30 calendar days.

3.21.5. MedWatch voluntary reports (~1,453 per month): death reports coded within 3 business days, injury reports within 4 business days, malfunction reports within 5 business days.

3.21.6. Critical 5-day reports: processed within 1 hour of receipt.

3.22. 803.22 Notifications: Contractors shall process 21 CFR Part 803.22 notifications using standard MedWatch voluntary report procedures, including required disclaimer text in the B5 field for submissions into LSMV.

3.23. Non-Medical Device Report Forwarding and Device Sample Handling: Reports concerning products not classified as medical devices (e.g., licensed biologics, drugs) shall be forwarded to the COR and/or TOPM for redirection and shall not be assigned a voluntary report number. Actual medical devices received shall likewise be forwarded to the COR and/or TOPM, with appropriate biohazard precautions if contamination is suspected.

3.24. Redaction Volume and Confidentiality for Voluntary Reports: Contractors must prepare and maintain redacted versions of approximately 356,487 MDR reports per month, including initial MedWatch 3500A/3500 forms and electronic supplemental reports received from July 1, 2015 onward. Upon receipt of voluntary reports, the contractor shall transmit an FDA-provided letter to the device manufacturer along with a redacted copy excluding the reporter's name, address, and phone number, unless confidentiality is not requested in Section G of the MedWatch 3500/3500B forms.

3.25. Photocopying/Digital Copying: Approximately 100 reports per month. Contractors must photocopy or create a digital copy (PDF) of original MDR reports upon FDA request or when the Contractor identifies a report warranting FDA attention.

3.26. Data Entry Demonstrations: Contractors shall conduct up to 12 demonstrations annually as requested by the COR and/or TOPM, showcasing MDR data entry procedures. Demonstrations may be delivered virtually or in person.

3.27. FDA-Originated Letters: Approximately 2,912 computer-generated FDA-originated letters per month. Contractors shall prepare these letters by manually inserting identifying information, folding, stuffing, and performing clerical tasks for mailing or emailing to manufacturers, user facilities, voluntary reporters, and importers. Contractors shall process and upload a copy of each letter to adverse event monitoring systems and track responses to additional information request letters.

3.28. Backlog Management: Contractors shall address the historical backlog of unresolved problem reports, consisting of approximately 15,000 reports previously in the Supplemental Hold inbox and 250 reports previously in the Data Entry inbox, prioritizing the oldest reports first.

3.29. UDI Support and MDR Issues Handling: UDI coding is a mission-critical part of the MDR collection and management process. Contractors are expected to support UDI processes in compliance with posted laws, regulations, and guidance, including addressing missing, incorrect, or redaction-required UDI entries. The processing of MDRs through LSMV may identify issues requiring manual data intervention; contractors are required to adhere to FDA-established procedures for identifying and addressing these issues.

3.30. Systems Development, Testing, and Validation Support: FDA information technology systems may periodically experience outages, modifications, upgrades, or accidental issues.

Contractors may be tasked with supporting process development, providing feedback on existing processes, conducting testing, performing error checks, validating systems and/or data, and participating in user testing activities to support system improvements.

3.31. Mail Room Operations: Contractors shall handle mail-related tasks at the FDA Mail Room located in White Oak Building 66, including sorting mail, prioritizing and triaging, scanning documents, tracking items, and distributing MDR reports to the FDA community.

3.32. Hours of Operation: Contractor staff shall be available during FDA standard business hours, Monday through Friday, from 8:00 a.m. to 5:00 p.m. Eastern Standard Time, excluding Federal Government holidays.

4. HUMAN FOOD PRODUCTS (HFP): HFP program requires a streamlined, integrated adverse event and complaint management system with end-to-end data management services to efficiently process mandatory and voluntary food, infant formula, and dietary supplement reports while reducing data entry burden and improving interoperability across FDA and federal systems. Requiring sophisticated capabilities including:

4.1. Scope of Complaint Intake: The system shall support intake, record management, surveillance, and tracking for all HFP complaint types, specifically including adverse events, product problems, and regulatory misconduct reports related to food (including infant formula) and dietary supplements.

4.2. Multi-Database Integration: The system shall integrate with HFP-specific reference datasets and databases, including but not limited to FoodTrak, the NIH Dietary Supplement Label Database, FMS, and MedDRA, to support automated data display, querying, and access across symptoms, product, firm, and other reference data.

4.3. Workflow Efficiency and Burden Reduction: The system shall measurably improve upon existing FDA data entry and workflow mechanisms by reducing time spent on record creation and search functions, representing a direct improvement over current HFP operational processes.

4.4. Streamlined FOIA, Congressional, and Responsive Request Extraction: The system shall include easy, efficient data extraction methods specifically designed to support FOIA, Congressional, and other responsive requests, addressing a known gap in current HFP capabilities.

4.5. CMS and Federal System Data Transmission: The system shall support streamlined, bidirectional data transmission with OII's Compliance Management System (CMS), FDA data warehouses, and other federal systems relevant to HFP operations.

4.6. Automated Product Identification: The system shall facilitate and automate product identification best practices while leveraging and maintaining HFP's regulated product reference data, reducing manual effort and improving data accuracy during report intake.

4.7. Automated Extraction of Outcomes and Seriousness Criteria: The system shall support automated extraction of outcomes, seriousness criteria, and other key parameters directly from submitter-provided data, minimizing manual review burden on HFP staff.

4.8. HFP-Optimized User Interface: The system's user interface shall be specifically streamlined for HFP key data elements and workflows, ensuring critical functions are easily accessible and do not impose undue burden on data entry and record management staff.

4.9. Bulk Search and Extraction of Reports and Attachments: Reports and all associated attachments shall be easily searchable and extractable in bulk, supporting efficient surveillance, analysis, and responsive request fulfillment.

4.10. Multi-Format Report Intake: Contractors shall support accurate data intake across electronic, paper, PDF, and other formatted report submissions, encompassing both mandatory industry submissions and voluntary reports from consumers and healthcare professionals.

5. CENTER FOR VETERINARY MEDICINE (CVM) - The CVM requires two distinct but complementary system components — one for animal drugs and one for animal foods — each supporting species-specific adverse event reporting, VeDDRA-based medical coding, and end-to-end data management services, with the animal drugs component additionally requiring VICH-harmonized electronic reporting (including standardized VICH GL42 vocabularies), advanced signal detection analytics customized for veterinary products , and antimicrobial resistance monitoring. Requiring sophisticated capabilities including:

5.1. Dual System Architecture: The system shall maintain two separate components — CVM Drugs and CVM Foods — each tailored to their respective surveillance domains while operating within the broader consolidated AEMS framework. CVM Drugs and CVM Foods programs are two distinct systems, reflecting operational and regulatory differences between the two surveillance domains.

5.2. Report Processing and Trage: Support mandatory industry submissions, voluntary consumer reporting, and veterinary professional reporting through standardized registration workflows that ensure appropriate case prioritization and regulatory timeline compliance across all submission pathways.

5.3. Multi-Species and Group-Level Reporting: Both components shall support adverse event reporting across a wide variety of animal species and breeds within species and shall accommodate individual reports involving groups of animals such as herds and flocks, reflecting the unique nature of veterinary pharmacovigilance.

5.4. VeDDRA Coding: Both components shall incorporate VeDDRA (Veterinary Dictionary for Drug- Regulatory Activities) coding for veterinary adverse events. The animal drugs and animal foods versions of VeDDRA are distinct and independently maintained resources, each reflecting the tailored terminology requirements of their respective surveillance domains. For the CVM Drugs component, annual VeDDRA vocabulary updates are required and maintained on a scheduled basis.

In addition, CVM Drugs utilizes a regionally maintained list of CVM-specific terms (e.g., product defect terms, medication errors), which shall also be dated and maintained separately from the core VeDDRA dictionary. For CVM Foods, VeDDRA vocabulary updates are applied on an ad hoc basis, at the direction and request of CVM Foods subject matter experts

5.5. CVM Animal Drugs — Unique Requirements includes Post-Market and Pre-Market Surveillance: The system shall support post-market safety surveillance for both approved, conditionally approved, indexed, and unapproved animal drugs and devices. The system should also support pre-market safety monitoring for investigational veterinary products as a future-state capability.

5.6. Product Quality Defect Reporting: The system shall support the intake, management, and analysis of product quality defect reports specific to animal drug products as well as for animal foods, in addition to adverse event reports received for animal foods and drugs.

5.7. Advanced Signal Detection and Analytics: The system shall provide validated advanced analytical capabilities including statistical algorithms and signal detection and data mining techniques that operate across all levels of the VeDDRA hierarchy to identify potential veterinary safety signals.

The tool shall support quantitative signal detection through disproportionality methods employed by CVM (e.g., proportional reporting ratio, information component floor, Bayesian statistical methodologies)

5.8. VICH-Harmonized Electronic Reporting: The system shall support and align with internationally harmonized electronic reporting standards for veterinary medicinal products developed under VICH, including compliance with CVM GFI#188, GFI#214, GFI#143, the FDA CVM Step-by-Step Guide, and FDA CVM Validation Procedures. This does not apply to the CVM Foods module.

5.9. Electronic Report Validation and Acknowledgment: The system shall validate incoming electronic reports from industry stakeholders and automatically generate and transmit acknowledgment messages upon receipt and processing.

5.10. Automated Field Alert Report Distribution: The system shall automatically send email copies of field alert reports received by CVM Drugs to the appropriate FDA OII Divisions/district offices upon receipt, without requiring manual intervention.

5.11. Veterinary Product Labeling Integration: The CVM Drugs component shall support integration with veterinary product labeling data to facilitate cross-referencing of adverse event reports with approved product labeling information.

5.12. Antimicrobial Resistance Monitoring: The system shall include functionality to support antimicrobial resistance monitoring as part of CVM's animal drug safety surveillance mission.

5.13. Customized Queries, Dashboards, and Reporting: The system shall provide customizable queries — including both text and field/code list searches — along with dashboards, metrics tracking, and customizable reports to support CVM safety oversight and regulatory decision-making.

5.14. Regulatory Submission Tracking and Management: The system shall support comprehensive tracking and management of regulatory submissions associated with animal drug adverse event reporting.

5.15.…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .