Fall Protection RFQ_11_20_26.pdf
PDF 275 KB Posted
- Solicitation number
- 345-11/23/2026
- Issued by
- Camden County, North Carolina
About this file
Fall Protection RFQ Summary
This is a Request for Qualifications (RFQ) issued by the Cape Fear Public Utility Authority (CFPUA) in Wilmington, North Carolina, for professional engineering firms to provide fall protection assessment, design, and implementation services. The project scope encompasses evaluating and implementing fall protection systems across CFPUA water and wastewater utility facilities, including pump station wet wells, treatment plants, elevated work platforms, access hatches, and other locations with fall hazards. The selected firm must demonstrate experience with existing concrete structures in water and wastewater infrastructure while maintaining structural integrity. Statements of Qualifications must be submitted in PDF format to bids@cfpua.org by 2:00 PM on December 15, 2026, with a question deadline of 2:00 PM on December 8, 2026. SOQs are limited to 25 pages, excluding cover pages, tabs, resumes, and appendices, with a maximum file size of 25 MB. The selection schedule will be determined for each task order, and selected firms will be notified by telephone or email.
The evaluation of submissions will be conducted by a CFPUA selection team based on firm experience, proposed personnel qualifications, knowledge of utility operations, innovative ideas, familiarity with local conditions, quality control programs, and cost management records. Engineering firms must comply with North Carolina General Statutes 143-64.31 through 64.34 (Mini Brooks Act) and maintain specific insurance coverage including General Liability ($1,000,000/$2,000,000), Workers' Compensation ($500,000/$500,000/$500,000), Auto Liability ($1,000,000 combined single limits), and Professional Liability (minimum $2,000,000 per loss), with the Authority designated as additional insured. A detailed fee schedule will be negotiated with the best qualified firm, and CFPUA reserves the right to reject any submissions. Firms must be properly registered with the North Carolina Office of the Secretary of State.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
REQUEST FOR QUALIFICATIONS FOR
FALL PROTECTION ASSESSMENT, DESIGN, IMPLEMENTATION SERVICES
FOR CAPE FEAR PUBLIC UTILITY AUTHORITY
WILMINGTON, NORTH CAROLINA
November 23, 2026
GENERAL
Cape Fear Public Utility Authority (CFPUA) is seeking Statements of Qualifications (SOQs) from qualified professional engineering firms and consultants experienced in the assessment, design, and implementation of fall protection systems for water and wastewater utility facilities.
The purpose of this project is to assess existing working conditions and implement appropriate fall protection devices, systems, and equipment to enhance employee safety and mitigate or eliminate the risk of falls at CFPUA facilities.
Specific applications will include, but are not limited to, wastewater pump station wet wells, water and wastewater treatment plants, elevated work platforms, access hatches, and other locations where employees may be exposed to fall hazards during routine operations, maintenance, inspections, or emergency activities.
The selected firm shall demonstrate experience in evaluating, modifying, and working with existing concrete structures associated with water and wastewater infrastructure. Fall protection solutions must maintain the structural integrity of existing concrete facilities while providing safe, durable, and reliable installations.
SUBMISSION OF QUALIFICATIONS STATEMENT
Firms are invited to submit a Qualifications Statement to the CFPUA by no later than 2:00 PM on December 15, 2026. Qualifications received after this deadline will not be considered.
CFPUA will address questions regarding the RFQ until 2:00 PM on December 8, 2026.
Questions submitted after this deadline will not be addressed. Questions concerning this advertisement should be directed to Ben Guerrieri, Procurement Manager, Cape Fear Public
Utility Authority, at bids@cfpua.org.
SOQ’s shall be limited to twenty-five (25)-pages or less, excluding cover page, tabs, resumes and appendices.
mailto:bids@cfpua.org
Firms shall submit their statement of qualifications for consideration in pdf format to bids@cfpua.org. Maximum file size for pdf submission is 25MB. A reply will be sent to the email address submitting the statement of qualifications to confirm receipt. It is the submitting firms responsibility to confirm that CFPUA has received statement of qualifications via email. If email reply is not received from bids@cfpua.org, please call 910-332-6472 or 910-332-6651 before deadline for submission.
Submitted information shall comply with N.C.G.S. 143-64.31 through 64.34 (aka Mini Brooks
Act).
SOQ’s will be evaluated by a CFPUA selection team.
Firms submitting Qualifications are encouraged to carefully check them for conformance to the requirements stated herein. Qualifications that do not meet ALL of the below listed requirements, or are sent to any email address other than that shown above, will be disqualified.
No exception will be granted.
EVALUATION
Firms submitting Qualifications to perform Fall Protection Services will be evaluated based upon the firm’s experience, proposed personnel experience, personnel knowledge and familiarity with typical CFPUA scope of work. This scope is defined in the General section of this Request for
Qualifications.
Consultants must demonstrate their level of competence and qualification with respect to the listed evaluation factors for the needed services.
Evaluation factors include:
1. Educational background and professional registrations of key consultant personnel.
2. Size and experience of the consultant’s professional and technical record of success by the consultant, demonstrated by work previously performed for CFPUA or similar work performed for others.
3. The ability of the consultant to work effectively with CFPUA staff, other agencies, and related parties.
4. Pertinent new ideas that may be presented by the consultant during the course of the selection process.
5. Whether the consultant has adequate knowledge of local conditions.
6. Whether the consultant has an effective quality control program.
7. The consultant’s record of keeping costs within project budgets.
A detailed fee schedule will be negotiated with the best qualified firm. If negotiations are not successful, CFPUA will terminate negotiations with that firm and initiate negotiations with the next best qualified firm.
SCHEDULE
Schedule shall be determined for each Task Order.
REQUIREMENTS
Qualifying Statements shall include:
1. Firm name, address, telephone number, fax number, email address, and contact person(s).
2. Year in which the firm was established and any former names under which the firm operated.
3. Qualifications and experience of personnel who would be design services for the project(s) by providing:
a. A list of design projects demonstrating experience/understanding of the experience described in the General section above. Project information shall include:
i. a summary of the scope of work and deliverables,
ii. the owner of the project, and
iii. the name, number and email of a reference for the project.
Engineering Firm Requirements
The following criteria will be deemed necessary for selection:
• The firm must meet the following insurance requirements. Workers’ Compensation may be waived if firm has no employees.
• General Liability $1,000,000 per occurrence/$2,000,000 aggregate. Authority must be additional insured and endorsement required.
• Workers Compensation $500,000/$500,000/$500,000. Waiver of Subrogation against the
Authority and endorsement required.
• Auto Liability Insurance $1,000,000 per occurrence combined single limits applicable to claims due to bodily injury and/or property damage. Authority must be additional insured and endorsement required.
• Professional Liability not less than $2,000,000 per loss.
Any firm wishing to be considered must be properly registered with the Office of the Secretary of State.
NOTIFICATION
The selected firms will be notified by telephone and/or email. The CFPUA reserves the right to reject any and all submissions.
File details come from the government source that posted it. Updated .