Falcon 4 Manual with Specifications.pdf
PDF 973 KB Posted
- Attached to
- FALCON 4. 8 REPLACEMENT PANELS
- Solicitation number
- FA301624Q5039
About this file
This document appears to be a user manual for the Falcon 4 LED video wall panel. It provides detailed specifications and installation instructions for the Falcon 4 panel, including physical dimensions, electrical requirements, operating conditions, and maintenance procedures.
The related federal contract opportunity is a pre-solicitation notice from the Department of the Air Force Air Education and Training Command seeking potential sources to supply thirty-six (36) Falcon 4 video wall panels, thirty-six (36) Nova receiving cards, six (6) road cases, one (1) image control and switching unit, and one (1) Nova LED sender card. The government is conducting market research and requests responses by April 5, 2024 at 4:00pm Central. The required equipment appears to be for replacement or supplementary components for an existing video wall system.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| RFI - Falcon 4.8 Panels.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
USER MANUAL
Table of Contents Safety Information……………………………………...………………3 Specifications………………………………………...…………………4 Main Power Connection…………………………...…………………..5 Signal Connection…………………….…………..…………………...5 Rigging the Fixture……………………………………………………..6 Installation………………………………………………………………6 Parts List………………………………………………………………..7 Accessories……………………………………………………………..8 Cleaning & Maintenance
Check that the unit has not been damaged during transport
Protection Against Fire
1. Maintain a minimum of 1 foot distance from any type of flame.
2. Do Not install the unit to close to a heat source.
3. Make Sure cables are properly secured
4. Maximum surface operating temperature below 115°f
5. Do not operate panel with out secondary ethernet connection covered.
Protection Against Electrical Damage
1. Disconnect power before servicing.
2. For connection to main power supply proceed to page 6.
3. This unit must be earthed. (electronically grounded)
4. Unit must not be left on for a long period of time.
Protection Against Mechanical Hazards
1. Use secondary safety when hanging unit.
2. Use quality rigging equipment when positioning unit.
3. Do not excessed number of hanging units per suspender.
4. Do not ground stack the unit with out proper hardware.
Ingress Protection
IP 65
The IP rating is commonly expressed as IP (Ingress Protection) is followed by 2 numbers (i.e. 65) where the numbers define the fixture rating. The first number indicates the size of a particle that can enter the fixture.. The second number indicates the extent of protection against water entering the fixture. An IP65 rating in this fixture indicates that dust particles can not enter the fixture. And there is protection against powerful water spray from entering the fixture from any direction.
Specifications
Item# MV314 = Falcon 4 IP Pixel Pitch 4.8
LED Type SMD1921 Black Face
Panel Pixel Count 104 x 208
Physical Panel Density Count 21632
Parameter Panel Size 500 X 1000 X 70mm
Module Size 250mm X 250mm
Panel Weight 26.5lb / 12kg
Module Weight 1.76lb / .8kg
Receiving Card Subito
Grayscale (bit) 12-14bit
Grayscale per color (level) 12-14bit
Electronics Refresh Rate (specified at ordering) 1920-3840
Driving Type 1/16
Driving IC ICN-2153
Signal Distance CAT5 Cable 100M
Brightness (nit) 3000nit
Optical Optimal Viewing Angle Horizontal 160°
Optimal Viewing Angle Vertical 160°
AC Input Voltage 100-240V AC 50/60Hz
AC Power Supply Max 300W
AC Maximum Power Input (Full White) 233W / 1.96Amp
AC Average Power Input 150W
Electrical Power Connection Panel Mount Seetronic In/Out
Signal Connection Panel Mount Seetronis Ethernet In/Out
Power Supply G Energy
Power Link at 110V (using Nema 5-15 connection) 8
Power Link at 220V (using Nema 6-20 connection) 20
IP Rating IP 65 Outdoor / Indoor Use
Ambient Average LED lifetime 100,000 Hours
Conditions Working Ambient Temperature 0-40
Working Humidity (RH) 10%-60% Non Condensing
Vertical Rigging Quantity (pcs) Sus 1 =10 / Sus 2=20 / Sus3=30
Installation Stacking Quantity (pcs) with appropriate hardware 20
Optional Curve Panel Available -10° / +10°
Service Screw Module
Specifications and Certification are subject to change with out any prior notice
Main Power Connection
Caution!
1. This unit must be earthed. (electronically grounded)
2. Replace fuse only with the specified type and rating.
3. Power link maximum 8 units at 110V
4. Power link maximum 20 units at 220V
5. Unit uses 2 power female receptacles it is very important to not connect a second separate input feeds into the output labeled connection. They are in-tended to be used as power In and Outputs as labeled.
The occupation of the connection-cable is as follows:
This device is equipped with a auto switching power supply that will allow you to work from 100V-240V 50/60Hz
Caution!
Signal cable should not travel near high output power. As not to interfere with signal Signal cable should not be longer than 100 Meters.
Cable (USA) Cable (EU) Pin 110V
Black Brown
White
Green
Light Blue
Yellow/Green
Live
Neutral
Ground
L
N
220V
110V Connection
220V Connection
N
L
Signal Connection
The fixture is equipped ethernet panel Sockets for signal input and output. Only use a multiple twisted pair cable de-signed for ethernet., in order to connect the controller with the panel or the panel with another.
Caution!
1. The installations must be carried out by an authorized dealer or trained professional.
2. Unit may cause severe injures if you have doubts concerning the safety do not install.
3. Unit is to be 24inches away from flammable materials (decoration material)
4. Use high quality installation equipment to hang unit.
When rigging a unit it is very important that you follow common safety procedures. Rigging requires extensive experi-ence including but not limited to calculating working loads, material being used and periodic safety inspections. If you lack these qualifications, do not attempt the installation yourself, instead use a professional structural rigger.
When rigging the unit always be secured with a secondary safety attachment. The installation location of the panels has got to be built in the way that it can hold 10 times the weight for 1 hour with out any harming. Installation should be checked at least one time a year by a skilled person.
Rigging the Fixture
1. Latch has to be positioned in in the clockwise turning position were the red Open tap is visible.
2. Push latch into the receiving latch position. Make sure the latch insert has passed the locking point and will not release if pulled back
Latch Installation
3. Before tightening the latch make sure the panel is at the correct level and depth as what you would like.
4. Turn the latch counter clockwise so the blue Closed label is showing
1. Press the red release trigger over the closed latch and hold down wile at the same time turning the latch clockwise to loosen latch
Releasing Latch
5. Press on the release pin on the receiver latch to release the main shaft of the latch. For side latch the spring latch will automatical-ly spring out of position. For top latch the latch gravity will re-lease the latch
FALCON 314 ITEM LIST
Part Number Description
MV-300-SUS-3 FALCON 3 UNIT SUSPENDER
MV-300-SUS-2 FALCON 2 UNIT SUSPENDER
MV-300-SUS-1 FALCON 1 UNIT SUSPENDER
MV-300-SUS-CLA SUSPENDER TRUSS CLAMP
MV-300-SUS-EYE SUSPENDER EYE BOLT
MV-300-CAB-POW-LEA POWER LEAD CABLE WITH NEMA 5-15
MV-300-CAB-POW-JUM POWER JUMPER CABLE
MV-300-CAB-SIG-LEA SIGNAL LEAD CABLE
MV-300-CAB-SIG-JUM SIGNAL JUMPER CABLE
CAS-MV-300-6 6 UNIT ROAD CASE
MV-300-HOU-JOI 4 UNIT JOINER
MV-314-REC SUBITO RECEIVING CARD
PARTS
MV-314-LED REPLACEMENT LED
MV-314-LED-MOD REPLACEMENT LED MODULE
MV-314-HUB REPLCEMENT HUB
MV-300-HOU-LAT-TOP TOP LATCH
MV-300-HOU-LAT-SID SID LATCH
MV-314-POW POWER SUPPLY
MV-314-MAS LED MASK
MV-300-SUS-JOI SUSPENDER JOINER
Parts List
Accessories
MV-300-SUS-3
MV-300-SUS-2
MV-300-SUS-1
MV-300-SUS-CLA MV-300-SUS-JOI MV-300-HOU-JOI
Cleaning and Maintenance
Installation Maintenance: The operator has to make sure that the unit is operating safely and has the installations and electronics checked by an expert every 2 years.
The following points have to be considered during the inspection:
1) All screws used for installing the device or part of the device have to be tightly connected and must not be corroded.
2) There must not be any deformations on the housing, fixation and installation spots (ceiling, suspension, trussing).
3) The electronic power supply cables must not show any damages, material fatigue (e.g. porous cables) or sediments.
Further instructions depending on the installation spot and usage have to be adhered by a skilled installer and any safety problems have to be removed.
Disconnect from mains before starting maintenance operation!
Caution Danger to life!
We recommend a frequent cleaning of the device. Please use a moist, lint free cloth. Never use alcohol or solvents!
1) The objective lens will require periodic cleaning on usage and environment. Environment with foggers will require more periodic cleaning as fog fluid tends to build up residues, reducing the light output.
2) Lenses may be cleaned with soft brush using soapy water.
3) The interior of the fixture should be cleaned using a vacuum.
Note: There is no serviceable parts inside the device . Maintenance and service operations are to be carried out by au-thorized dealers.
Replacing the fuse: There is no service fuse inside the fixture.
Replacing the power cable: If the power cable of this device becomes damaged, it has to be replaced by authorized dealers only
Should you have further questions , please contact your dealer.
18668 Highway 16N Helotes, TX 78023
Ph 210-684-2600 Fax 210-855-6279 www.mega.lighting / info@mega.lighting.com
Warranty Information
Warranty Conditions -Unless otherwise stated in writing, your product is covered by a one year parts and labor limited warranty.
-LED’s are not guaranteed to match in color or output.
-It is the owner’s responsibility to furnish receipts or invoices for verification of purchase, date, and reseller or distributor.
If purchase date cannot be provided, date of manufacture will be used to determine warranty period.
-Goods returned under warranty must follow the proper authorization procedure and must be accompanied by a copy of the original invoice.
-Goods repaired under warranty will be returned to the owner with the freight prepaid by MSI via the most economical means of shipment.
-Repair or replacement as provided for under this warranty is the exclusive remedy of the consumer. MEGA SYSTEMS INC. makes no warranties, express or implied, with respect to any product, and Mega Systems specifically disclaims any warranty of merchantability or fitness for a particular purpose. Mega Systems shall not be liable for any indirect, inci-dental or consequential damage, including lost profit, sustained or incurred in connection with any product or caused by product defect or the partial or total failure of any product regardless of the form of action, weather in contract, tort (including negligence), strict liability or otherwise, and weather or not such damage was foreseen or unforeseen.
- Warranty is void if the product is misused, damaged, modified in any way, or for unauthorized repairs or parts. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
Customer Support
Mega View has a customer support line to provide set up help and to answer any question should you encounter a prob-lem. Please visit our website for any other related technical documents. For service related issue please contact our service dept.
Monday—Friday 9am to 6pm CST Voice: 210-684-2600 E-mail: service@megasystemsinc.com
Specifications in this manual are subject to change.
Document Version
Date Fixture Soft-ware Notes
1.1 12/19/2019 V1.1
Manual Version
Please Visit www.megasystemsinc.com for the most up to date manual version
File details come from the government source that posted it. Updated .