This document is technical specification data for Pentair's 5430 M & W submersible solids handling pumps, published in February 2018. It is not a solicitation document, contract vehicle, or procurement-related file, but rather a manufacturer's technical reference guide.

The document provides comprehensive technical specifications for multiple pump models within the 5430 series, including the D5430MT (tangential discharge), D5430MV (centerline discharge), D5430WD (dry pit submersible), and D5430W (base mounted submersible), available in frame sizes ranging from 210 to 440. Specifications detailed include pump sizes from 2 to 10 inches, impeller fastener sizes and torque requirements, inlet areas, maximum sphere sizes that can pass through the pumps (ranging from 1.5 inches to 6 inches depending on model), hydrostatic test pressures (ranging from 65 to 225 psi), casing working pressures (45 to 150 psi), maximum operating temperatures (104°F for D series, 150°F for A series), and complete weight data for pump and motor combinations. The document specifies standard mechanical components including enclosed radial flow impellers with two-vane or bladeless options, axial wear rings, tandem mechanical seals with ceramic and tungsten carbide faces, oil-lubricated bearings with 50,000-hour L10 life ratings, submersible squirrel cage motors rated for 60 Hz at 230 or 460 volts, and dual moisture detectors. Optional features include various seal materials, continuous duty in air configurations, water cooling jackets, and external cooling requirements ranging from 3 to 25 GPM depending on motor frame size.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

February © 2018 Pentair plc 123

Technical Data – 5430 M & W SUBMERSIBLE SOLIDS HANDLING PUMPS

A/D5430MT/MV/W/WD

Wet End Vertical, solids handling impeller Rotation CW when viewed from driver end Volute Single, one-piece, constant velocity Nozzles Bottom suction, horizontal discharge Impeller Single-suction, radial flow, enclosed

Bladeless (optional) Wear Rings Axial type wear rings (optional) Shaft Integral motor, shims for impeller adjustment Bearing Frame Motor frame Bearing Radial/Thrust Integral motor Lubrication – Seal Oil Motor Submersible, constant speed, squirrel cage, 3 phase, 60 Hz, 230 or 460 volt through 250 frame

320, 360, 400 and 440 frame, 460 volt only. 1.15 service factor thermal protectors and moisture sensing probes Mechanical seals with SST Nitrile components Upper mechanical seal stationary faces, ceramic with carbon rotating face Lower mechanical seal stationary faces, tungsten carbide with silicon carbide rotating face Tungsten carbide rotating and silicon carbide stationary faces for upper mechanical seals (optional) Various voltages (optional) Continuous duty in air (optional) Continuous duty in air with water cooling jacket (optional) Viton® O-rings (optional)

Lifting Bail Pull-up lifting bail (not supplied on WD pumps 365 frame or smaller)

D5430MT

Volute Tangential Discharge Coupling Slip on flange type Discharge Base One-piece flanged inlet and vertical discharge Cable Pull-up cable (optional)

D5430MV

Volute Single one-piece, constant velocity Nozzles Bottom suction – Centerline discharge Discharge Coupling Pivot flange type Discharge Base One-piece flanged inlet and flanged vertical discharge Cable Pull-up cable (optional)

D5430WD

Fronthead Separate one-piece casting integral to volute on D5431 flanged for connection to suction elbow Base Mount Base and separate flanged suction elbow with cleanout Rotation CCW when viewed from driver end (optional)

D5430W Pump Mount One-piece low profile for low liquid level pumping

February © 2018 Pentair plc 124

A/D5431M/W A/D5432M/W/MV/MVK A/D5433M/W/MV/MVK

Pump Size (Discharge Size) 2 3 4 2 3 4 8 3 4 5 6 Suction Size (Standard) 2 3 4 2 3 4 8 3 4 5 6 Nominal Wear Ring (Axial) Clearance .015 .015 .020 .015 .015 .020 RTF .015 .020 .020 .025 Impeller Fastener:

Size 1/2–13 1/2–13 1/2–13 1/2–13 1/2–13 1/2–13 RTF 5/8–11 5/8–11 5/8–11 5/8–11 Tightening Torque (lbs.-ft.) 80 80 80 80 80 80 RTF 120 120 120 120 Impeller:

Weight (lbs.) 17.8 18.0 21.8 28.0 40.0 41.2 RTF 47.4 65.9 70.0 73.8 Inlet Area (sq. inches) 9.28 13.20 23.49 14.91 20.39 26.22 RTF 23.52 37.50 46.43 52.88 Sphere Size (Maximum) 1-1/2 2 2-1/2x3 1-1/2 2 3 RTF 2 3 3-1/2 3 Max. Hydrostatic Test, psi 65 65 65 90 90 90 RTF 125 125 125 125 Max. Casing Working, psi 45 45 45 60 60 60 RTF 85 85 85 85 Nominal Casing Thickness 5/16 5/16 5/16 3/8 3/8 3/8 RTF 3/8 1/2 1/2 1/2 Max. Operating Temperature (º F) D Series 104 104 104 104 104 104 104 104 104 104 104 Max. Operating Temperature (º F) A Series 150 150 150 150 150 150 150 150 150 150 150 Anchor Bolt Size, Recommended 7/8 7/8 7/8 7/8 7/8 7/8 RTF 7/8 7/8 7/8 7/8 Dry Pit Submersible Options:

Suction Size (Optional) –– 4 6 –– 4 6 –– 4 6 8 6 Vent/Priming Tap 1/4 1/4 1/4 1/4 1/4 1/4 RTF 1/4 1/4 1/4 1/4 Volute Cleanout Diameter –– 1-1/2 2 –– 4-1/2 2-7/8 N/A 2-1/4 2-7/8 4-1/4 4-7/8 Suction Elbow Cleanout Diameter 2 3 4 2 3 4 N/A 3 4 5 6 Min. Round Opening to Install Pump 28 30 32 30 32 34 RTF 36 40 40 40

All dimensions are in inches.

MV units are centerline volute discharge design.

Suction elbow available on WD units only.

For water jacketed motors, add the following weight to pump and motor:

250 frame + 85 lbs., 320 frame + 230 lbs., 360/365 frame + 245 lbs., 400 frame + 355 lbs., 440 frame + 460 lbs.

February © 2018 Pentair plc 125

D5434M/W D5435M/W D5436M/W

Pump Size (Discharge Size) 4 5 6 8S 8L 4 8 10 5 6 6L 8 8S Suction Size (Standard) 5 5 6 8 8 4 8 10 8 10 10 10 10 Nominal Wear Ring (Axial) Clearance

.020 .020 .025 .025 .025 .015 .025 .030 .020 .025 .025 .025 .025

Impeller Fastener:

Size 3/4–10 3/4–10 3/4–10 3/4–10 3/4–10 7/8–9 7/8–9 7/8–9 7/8–9 1-1/4–7 1-1/4–7 7/8–9 1-1/4–7 Tightening Torque (lbs.-ft.) 200 200 200 200 200 240 240 240 240 240 240 240 240 Impeller:

Weight (lbs.) 103.0 89.3 169.3 102.1 102.1 103.0 302.0 380.0 89.3 133.0 125 342.0 125 Inlet Area (sq. inches) 47.01 58.39 * 62.99 x 35.65 # 127.43 52.05 59.32 93.3 93.22 93.3 Sphere Size (Maximum) 3 4 * 3-1/2 x 3 5 6 3 3 3 5 3 Max. Hydrostatic Test, psi* 160 80 80 80 80 190 115 115 190 225 225 150 225 Max. Casing Working, psi* 100 75 75 75 75 125 75 75 125 150 150 100 150 Nominal Casing Thickness 9/16 1/2 1/2 1/2 1/2 11/16 3/4 3/4 11/16 7/8 7/8 3/4 7/8 Max. Operating Temperature (º F)* 104 104 104 104 104 104 104 104 104 104 104 104 104 Anchor Bolt Size, Recommended 7/8 7/8 7/8 7/8 7/8 7/8 1-1/8 1-1/8 7/8 7/8 7/8 7/8 7/8 Dry Pit Submersible Options:

Suction Size (Optional) 6 or 8 6 or 8 8 10 10 6 10 or 12 12 10 –– –– –– –– Vent/Priming Tap 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 Volute Cleanout Diameter 2-7/8 4-1/4 4-1/4 4-7/8 4-7/8 2-7/8 5-1/8 4-7/8 3-7/8 5-1/8 5-1/8 5-1/8 5-1/8 Suction Elbow Cleanout Diameter 5 5 6 6 6 3 6 6 6 6 6 6 6 Min. Round Opening to Install Pump 46 48 50 52 52 46 68 70 48 58 58 68 58 Weights:

Pump and Motor 210T 640 860 1075 1085 1135 850 –– –– 1070 –– –– –– –– 250T 1140 1095 1300 1280 1350 1590 –– –– 1145 1500 –– –– –– 320T 1660 1695 1750 1800 1850 1750 2550 –– 1845 2000 2000 –– 2100 360T 2100 2145 2200 2250 2300 –– 3000 3200 2150 2450 2450 3050 2400 365T 2300 2250 2400 –– –– –– 3200 3350 2350 2650 2650 3250 2750 400T –– –– –– –– –– –– 4300 4500 3250 3500 3450 4350 3550 440T –– –– –– –– –– –– –– 5900 –– 5295 5295 5700 5000 MV or MT Base/Elbow Adder 4" Elbow 110 –– –– –– –– 80 –– –– –– –– –– –– –– 6" Elbow 150 150 150 –– –– 150 –– –– 150 150 150 150 –– 8" Elbow –– 230 230 230 230 –– 230 –– 230 230 230 230 230 8" Elbow for 400T & 440T Frame –– –– –– –– –– –– 840 840 840 840 840 840 840 10" Elbow –– –– –– 970 970 –– 970 970 –– –– –– 970 970 WD Base and Elbow Adder 200 230 245 305 315 200 285 375 265 410 410 410 410

All dimensions are in inches.

* TAJC5BH impeller has an inlet area of 60.58 sq. in. and can pass a 3" sphere; TAJC5BJ impeller has an inlet area of 64.55 sq. in. and can pass a 3" sphere; TAJC5DC impeller has an inlet area of 70.85 sq. in. and can pass a 4" sphere.

x T8D1A impeller has an inlet area of 62.99 sq. in. and can pass a 4" sphere; T8D1D impeller has an inlet area of 72.94 sq. in. and can pass a 4" sphere; TAKC5W impeller has an inlet area of 99.93 sq. in. and can pass a 5" sphere.

# TAKE5U impeller has an inlet area of 108.36 sq. in.; TAKE5N impeller has an inlet area of 130.29 sq. in.

Suction elbow available on WD units only.

For water jacketed motors, add the following weight to pump and motor:

250 frame + 85 lbs., 320 frame + 230 lbs., 360/365 frame + 245 lbs., 400 frame + 355 lbs., 440 frame + 460 lbs.

*These are maximum values based on standard construction. If higher values are required, contact the factory.

February © 2018 Pentair plc 126

CABLE

Power and control cable are UL Listed and CSA Approved.

ELECTRICAL CONNECTION

Double-seal system with strain relief, consisting of a rubber grommet followed by epoxy. Individual wires have the insulation removed prior to epoxy potting to prevent wicking into the motor.

Wires are terminated with connectors secured to bronze lugs on the O-ring sealed terminal board. Stator and control leads from the motor are attached to the underside of the lugs.

SHAFT

Solid 416 stainless steel, precision machined, to ensure a tight fit of the impeller and rotor onto the shaft.

MECHANICAL SEALS

Two separate tandem mounted seals to protect the motor from the pumped liquid. Upper seal is carbon against ceramic faces. Lower seal is silicon carbide against tungsten carbide faces.

STAINLESS STEEL BOLTS

External bolts are stainless steel for ease of maintenance.

IMPELLER

Enclosed radial flow, two-vane or bladeless design, with blunt rounded leading edges and thick hydrofoil shape to pass large solids and stringy material. One-piece cast impellers are designed for circular flow to match in the equalizing-pressure, thick walled volute.

WEAR RINGS

Impeller and volute may be fitted with axial wear rings hardened to 300 – 350 Bhn or higher stainless steel.

SOLIDS PASSING

Spherical solids passing through the impeller and volute can also pass between the volute cutwater and a full diameter impeller.

SLIDING BRACKET ASSEMBLY

Non-sparking, UL Listed hazardous location bronze. When lowered onto the discharge base/elbow, a knifing action of the vertical metal-to-metal, self-cleaning connection is secured.

DISCHARGE BASE/ELBOW

Heavy-duty cast iron, 125 lb. ANSI flange supporting the total weight of the pump.

OIL INSPECTION PLUGS

Removable O-ring sealed plugs for easy inspection and to change oil in the seal chamber.

TWO MOISTURE DETECTORS

Detects moisture entering the oil cavity or stator housing and sends a signal to a compatible controller.

BEARING LIFE

Oil lubricated thrust bearing and radial bearing with an L10 bearing life of 50,000 hours at BEP.

THERMOSTATS

Imbedded in the motor windings to protect from overheating. These devices reset automatically. Excessive heat will cause the normally closed contact to open, stopping the motor.

PULL-UP SYSTEM

Two rails mounted on the discharge base/elbow provide a guide for the pump when raised or lowered.

Technical Data – 5430MV 210/250/320/360/365/400/440 FRAME

CENTERLINE DISCHARGE PULL-UP SUBMERSIBLE

February © 2018 Pentair plc 127

Technical Data – 5430MT 210/250/320/360/365/400/440 FRAME

TANGENTIAL DISCHARGE PULL-UP SUBMERSIBLE

CABLE

Power and control cable are UL Listed and CSA Approved.

ELECTRICAL CONNECTION

Double-seal system with strain relief, consisting of a rubber grommet followed by epoxy. Individual wires have the insulation removed prior to epoxy potting to prevent wicking into the motor.

Wires are terminated with connectors secured to bronze lugs on the O-ring sealed terminal board. Stator and control leads from the motor are attached to the underside of the lugs.

SHAFT

Solid 416 stainless steel, precision machined, to ensure a tight fit of the impeller and rotor onto the shaft.

MECHANICAL SEALS

Two separate tandem mounted seals to protect the motor from the pumped liquid. Upper seal is carbon against ceramic faces. Lower seal is silicon carbide against tungsten carbide faces.

STAINLESS STEEL BOLTS

External bolts are stainless steel for ease of maintenance.

IMPELLER

Enclosed radial flow, two-vane or bladeless design, with blunt rounded leading edges and thick hydrofoil shape to pass large solids and stringy material. One-piece cast impellers are designed for circular flow to match in the equalizing-pressure, thick walled volute.

WEAR RINGS

Impeller and fronthead may be fitted with axial wear rings hardened to 300 – 350 Bhn or higher stainless steel.

SOLIDS PASSING

Spherical solids passing through the impeller and volute can also pass between the cutwater and a full diameter impeller.

SLIDING BRACKET ASSEMBLY

Non-sparking, UL Listed hazardous location bronze. When lowered onto the discharge base/elbow, a knifing action of the vertical metal-to-metal, self-cleaning connection is secured.

DISCHARGE BASE/ELBOW

Heavy-duty cast iron, 125 lb. ANSI flange supporting the total weight of the pump.

OIL INSPECTION PLUGS

Removable O-ring sealed plugs for easy inspection and to change oil in the seal chamber.

TWO MOISTURE DETECTORS

Detects moisture entering the oil cavity or stator housing and sends a signal to a compatible controller.

BEARING LIFE

Oil lubricated thrust bearing and radial bearing with an L10 bearing life of 50,000 hours at BEP.

THERMOSTATS

Imbedded in the motor windings to protect from overheating. These devices reset automatically. Excessive heat will cause the normally closed contact to open, stopping the motor.

PULL-UP SYSTEM

Two rails mounted on the discharge base/elbow provide a guide for the pump when raised or lowered.

February © 2018 Pentair plc 128

Technical Data – 5430W 210/250/320/360/365/400/440 TANGENTIAL

DISCHARGE BASE MOUNTED SUBMERSIBLE

CABLE

Power and control cable are UL Listed and CSA Approved.

ELECTRICAL CONNECTION

Double-seal system with strain relief, consisting of rubber grommet followed by epoxy. Individual wires have the insulation removed prior to epoxy potting to prevent wicking into the motor.

Wires are terminated with connectors secured to bronze lugs on the O-ring sealed terminal board. Stator and control leads from the motor are attached to the underside of the lugs.

SHAFT

Solid 416 stainless steel, precision machined, to ensure a tight fit of the impeller and rotor onto the shaft.

MECHANICAL SEALS

Two separate tandem mounted seals to protect the motor from the pumped liquid. Upper seal is carbon against ceramic faces. Lower seal is silicon carbide against tungsten carbide faces.

STAINLESS STEEL BOLTS

External bolts are stainless steel for ease of maintenance.

IMPELLER

Enclosed radial flow, two-vane or bladeless design, with blunt rounded leading edges and thick hydrofoil shape to pass large solids and stringy material. One-piece cast impellers are designed for circular flow to match in the equalizing-pressure, thick walled volute.

WEAR RINGS

Impeller and fronthead may be fitted with axial wear rings hardened to 300 – 350 Bhn or higher stainless steel.

SOLIDS PASSING

Spherical solids passing through the impeller and volute can also pass between the volute cutwater and a full diameter impeller.

BASE

Heavy-duty base is designed to support the entire pump and bolts directly to the fronthead. Large opening between the base legs allows for even flow to the impeller eye.

OIL INSPECTION PLUGS

Removable O-ring sealed plugs for easy inspection and to change oil in the seal chamber.

TWO MOISTURE DETECTORS

Detects moisture entering the oil cavity or stator housing and sends a signal to a compatible controller.

BEARING LIFE

Oil lubricated thrust bearing and radial bearing with an L10 bearing life of 50,000 hours at BEP.

THERMOSTATS

Imbedded in the motor windings to protect from overheating. These devices reset automatically. Excessive heat will cause the normally closed contact to open, stopping the motor.

February © 2018 Pentair plc 129

Technical Data – 5430WD 210/250/320/360/365/400/440 TANGENTIAL

DISCHARGE DRY PIT SUBMERSIBLE

CABLE

Power and control cable are UL Listed and CSA Approved.

ELECTRICAL CONNECTION

Double-seal system with strain relief, consisting of rubber grommet followed by epoxy. Individual wires have the insulation removed prior to epoxy potting to prevent wicking into the motor.

Wires are terminated with connectors secured to bronze lugs on the O-ring sealed terminal board. Stator and control leads from the motor are attached to the underside of the lugs.

SHAFT

Solid 416 stainless steel, precision machined, to ensure a tight fit of the impeller and rotor onto the shaft.

MECHANICAL SEALS

Two separate tandem mounted seals to protect the motor from the pumped liquid. Upper seal is carbon against ceramic faces. Lower seal is silicon carbide against tungsten carbide faces.

IMPELLER

Enclosed radial flow, two-vane or bladeless design, with blunt rounded leading edges and thick hydrofoil shape to pass large solids and stringy material. One-piece cast impellers are designed for circular flow to match in the equalizing-pressure, thick walled volute.

WEAR RINGS

Impeller and fronthead may be fitted with axial wear rings hardened to 300 – 350 Bhn or higher stainless steel.

SOLIDS PASSING

Spherical solids passing through the impeller and volute can also pass between the volute cutwater and a full diameter impeller.

ELBOW

Suction elbow incorporates a 1/2" gauge connection and has 125 lb. flat faced flanges conforming to ANSI drilling. Elbow has large cleanout opening with contoured cover.

OIL INSPECTION PLUGS

Removable O-ring sealed plugs for easy inspection and to change oil in the seal chamber.

TWO MOISTURE DETECTORS

Detects moisture entering the oil cavity or stator housing and sends a signal to a compatible controller.

BEARING LIFE

Oil lubricated thrust bearing and radial bearing with an L10 bearing life of 50,000 hours at BEP.

THERMOSTATS

Imbedded in the motor windings to protect from overheating. These devices reset automatically. Excessive heat will cause the normally closed contact to open, stopping the motor.

BASE

Heavy-duty base is designed to support the entire pump and bolts directly to the volute. Large opening between the base legs permits access to the suction elbow and cleanout.

February © 2018 Pentair plc 130

CONTROL VALVE

BY OTHERS

125 PSI RATED MAXIMUM

INLET PRESSURE

REF. CIRCULATOR

REMOVED

(SUCTION SIDE OF PUMP OR DRAIN)

IN

OUT

THESE VALUES REQUIRE THAT THE WATER FLUSH TEMPERATURE BE 40º C OR LESS.

MAXIMUM WATER JACKET PRESSURE IS 150 PSI.

MINIMUM WATER JACKET PRESSURE IS 5 PSI

ABOVE SUCTION PRESSURE WHEN PIPING

THE WATER JACKET TO THE SUCTION LINE,

SUCTION ELBOW OR FRONTHEAD.

EXTERNAL COOLING IS NOT A UL APPROVED APPLICATION.

COOLING WATER JACKETS CAN BE SUPPLIED ON

PULL-UP SUBMERSIBLE (MT AND MV) DESIGNS

AS WELL AS THE BASE-MOUNTED SUBMERSIBLE

(W) DESIGNS.

THE COOLING JACKET USES A PORTION OF THE

LIQUID BEING PUMPED TO COOL THE MOTORS

ON APPLICATIONS THAT ARE CONTINUOUSLY

NON-SUBMERGED OR NON-SUBMERGED FOR

PERIODS LONGER THAN THE STANDARD DRAW-

DOWN TIME. THE JACKET IS PROTECTED WITH A

SELF-CLEANING ROTATING FLOW CONTROL DISC

WHICH MINIMIZES ANY SOLIDS FROM ENTERING

AND ACCUMULATING IN THE MECHANICAL SEAL

AREA OR WATER JACKET.

OIL DRAIN CAP

OIL FILL CAP

LOWER BEARING HOUSING

VOLUTE

THE OIL CHAMBER FILL/DRAIN DEVICE IS NOT UL APPROVED.

USE OF THIS DEVICE WILL VOID THE UL LISTING ON THE MOTOR.

THE EXTERNAL COOLING REQUIREMENTS FOR SUBMERSIBLE MOTORS ARE AS FOLLOWS:

210 FRAME NONE

250 FRAME 3 GPM

320 FRAME 6 GPM

360 FRAME 10 GPM

365 FRAME 10 GPM

400 FRAME RTF

440 FRAME 25 GPM

FLOW VALVE

0 – 30 GPM

BY OTHERS