This Statement of Work (SOW) outlines requirements for high power cables and POFA equipment needed by the Joint Navigation Warfare Center (JNWC) to transmit high power levels during Positioning, Navigation and Timing Operational Field Assessments (POFAs) and Field Test Exercises (FTXs).

The JNWC requires 58 coaxial cables and 40 connectors compatible with 1500-watt amplifiers in their NAVWAR EMI System (NEMISys). Key specifications include: ability to amplify 800-2000 MHz RF signals up to 1500W at specific frequencies (1575.42 MHz and 1227.6 MHz), handle 3300W max/2000W sustained power, maximum line loss of 4.3 dB/100ft, minimum bend radius of 2.75 inches, and operation in extreme conditions (-55C-200C) with IP67 weatherproofing. Required quantities include various cable lengths (10', 35', and 75' assemblies) and specific connector types (7/16 DIN and N-type female/male combinations) with heat shrink protection. All equipment must be delivered to the specified warehouse location.

View the file

Other files

File Type Posted
Single Source JA HighPowerCables signed Redacted.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STATEMENT OF WORK

TITLE: High Power Cables/POFA Equipment

Requiring Activity Name: Joint Navigation Warfare Center (JNWC)

1.0 OVERVIEW

1.1 BACKGROUND

1.2 SCOPE

JNWC has a requirement to transmit high levels of power for certain objectives during POFAs and FTXs. To be able to achieve this objective the JNWC needs cables and connectors that can handle the power that the 1500-watt amplifiers in the NEMISys are producing and effectively transfer it to the antennas. This must be done with the least amount of power loss through the cables as possible to increase efficiency, ultimately resulting in a better test environment. These high-power cables must also be flexible and rugged for the extreme environments the NEMISys are operated in.

1.3 OBJECTIVE

The JNWC’s is looking to acquire 58 coaxial cables and 40 connectors with the requirements listed below, in order to equip our NEMISys for high power jamming environments. Various cable lengths and connector types are required and are also listed in the requirements section below.

2.0 REQUIREMENTS:

• Electrical o Must be able to amplify 800-2000 MHz RF signal.

o Must be able to amplify 1575.42 MHz signal to at least 1500 watts.

o Must be able to amplify 1227.6 MHz signal to at least 1500 watts.

o Must be able to handle 3300W max and 2000W sustained power o Maximum line loss throughout cable cannot exceed 4.3 dB/100ft, not including connectors.

o Connectors must be able to pass the same frequencies at the same power levels.

• Mechanical

Joint Navigation Warfare Center Space Command’s Combined Space Force Component Command’s is the Department of Defense NAVWAR center of excellence responsible for planning and coordinating navigation warfare operations

JNWC

PNT Operational Field Assessments Field Assessments that the JNWC either hosts or assists in to further understand different aspects of PNT and maintain NAVWAR superiority

POFA

Field Test Exercises Field Test Exercises FTX Navigation Warfare NAVWAR is the deliberate defensive and offensive action to assure and prevent positioning, navigation, and timing information through coordinated employment of space, cyberspace, and electromagnetic warfare (EW) operations.

NAVWAR

NAVWAR EMI System The system JNWC deploys to transmit GNSS interference signals for tests and exercises

NEMISys

Global Navigation Satellite System A system that uses satellites to provide autonomous geopositioning with global coverage.

GNSS

Radio Frequency The oscillation rate of an alternating electric current or voltage or of a magnetic, electric or electromagnetic field or mechanical system in the frequency[1] range from around 20 kHz to around 300 GHz.

RF

Decibel a unit used to measure the intensity of a sound or the power level of an electrical signal by comparing it with a given level on a logarithmic scale.

dB

Decibel milliwatts Decibel milliwatts dBM Hertz SI unit of frequency, equal to one cycle per second.

Hz

Megahertz Represents one million hertz. Hertz is the standard unit of frequency in the International System of Units.

MHz

Gigahertz Represents one billion hertz. Hertz is the standard unit of frequency in the International System of Units.

GHz