This document is a preliminary floor plan layout for the renovation of Building 737 at Kirtland Air Force Base in New Mexico. The project is part of the broader MHMV210015 requirement to alter Buildings 737 and 733 in the 740 Area MSA, a controlled munitions area. The project has an estimated cost between $1,000,000 and $5,000,000.

The key details of the floor plan layout include: removing an existing wall, door, and frame; installing a new STC 50 rated wood door assembly with 20-minute fire rating and security hardware; converting existing walls to STC 50 sound assemblies; adding new 1-hour fire-rated overhead coiling counter doors and standard metal doors and frames; and constructing new gypsum board and metal stud walls, some extending to the deck. The layout also includes notes on maintaining fire-rated corridor walls, sloping ceilings, and exposed structure in certain areas.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

113 112

WOMEN'S RR

MEN'S RR

FLIGHT CHIEF

SECTION CHIEF

CLASSROOM

MAIN ENTRY

ELEC.

COMM.MECH. ROOM

C O

M P

R R

R M

ALTERNATE

MAINTENANCE

BAY

100111

TRAILER

MAINTENANCE

BAY

H A

Z M

A T

F

I R

E

C

A B

I N

E T

S

PROVIDE PAINT STRIPE

PARKING FOR CTKS

NCOIC/ASST

NCOIC

MUNITION

STOCKPILE

NCOIC

PRODUCTION

NCOIC

TK

OFFICE

OFFICE

MECH.

RM.

C O

R R

I D

O R

BREAK ROOM

OPERATIONS

CONTROL

TSGT

SPACE

STORAGE

DRAWN BY-

DATE-PROJECT NAME

REVISIONS

DESCRIPTION DATENO.

CHECKED BY:

APPROVED BY:

PROGRAM MANAGER:

PROJECT NUMBER

DESCRIPTION

FEDERAL

NetCentric Technology, LLC

DRAWING NO.

SUPPLEMENTARY

SCALE: 1/16"-1'-0"

BUILDING 737

N

Bldg 737 Floor Plan

Renovate B737 & B733 6/14/2023

K Hill MHMV-210015

J Manzanares

AE-1

KEYED NOTES

1. REMOVE WALL, DOOR & FRAME,

COMPLETE (APPROX. 17'-0")

2. STC 50 RATED WOOD DOOR ASSEMBLY

WITH 20 MIN. FIRE-RATING. PROVIDE

SECURITY HARDWARE. MATCH EXISTING

DOORS.

3. CONVERT EXISTING WALL TO STC 50

SOUND ASSEMBLY WALLS. EXTEND

WALLS TO DECK. MAINTAIN CORRIDOR

WALL AS A 1 HR FIRE-RATED ASSEMBLY.

4. NEW 1 HR FIRE-RATED OVERHEAD

COILING COUNTER DOOR.

5. NEW STANDARD HM DOOR AND FRAME.

6. NEW WALL, GYP BOARD, METAL STUD

TO DECK.

7. NEW WALL, STC 50, WITH 2 LAYERS

GYP BOARD EACH SIDE, METAL STUD

TO DECK.

8. NEW WALL, GYP BOARD, METAL STUD TO

10'-0" AFF.

9. NEW CEILING, LIGHT GAGE FRAME WITH

2 LAYERS OF GYP BOARD ON EACH SIDE.

10. CEILING SLOPES FROM 10'-0" AFF TO

ABOVE WINDOWS AT 13'-0" AFF.

11. EXPOSED STRUCTURE.

12. MAINTAIN CORRIDOR WALL AS A 1HR

FIRE-RATED ASSEMBLY, WHILE ADDING

ANOTHER LAYER OF 5/8" GWB. STC50

13. NEW WALL TOP BRACED @ 45° ANGLE AT

48" O.C. & EXTEND 6" ABOVE SLOPE

CEILING PLANE.

LEGEND

EXISTING WALL

NEW WALL TO DECK

TO BE REMOVED

NEW WALL TO CEILING

UP DATED KEYED NOTES 4/29/2024

AutoCAD SHX Text

2050 WYOMING BLVD SE, BLDG. 20686 KIRTLAND AIR FORCE BASE, NM 87117-5005