This document is a preliminary floor plan layout for the renovation of Building 737 at Kirtland Air Force Base in New Mexico. The project is part of the broader MHMV210015 requirement to alter Buildings 737 and 733 in the 740 Area MSA, a controlled munitions area. The project has an estimated cost between $1,000,000 and $5,000,000.
The key details of the floor plan layout include: removing an existing wall, door, and frame; installing a new STC 50 rated wood door assembly with 20-minute fire rating and security hardware; converting existing walls to STC 50 sound assemblies; adding new 1-hour fire-rated overhead coiling counter doors and standard metal doors and frames; and constructing new gypsum board and metal stud walls, some extending to the deck. The layout also includes notes on maintaining fire-rated corridor walls, sloping ceilings, and exposed structure in certain areas.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
113 112
WOMEN'S RR
MEN'S RR
FLIGHT CHIEF
SECTION CHIEF
CLASSROOM
MAIN ENTRY
ELEC.
COMM.MECH. ROOM
C O
M P
R R
R M
ALTERNATE
MAINTENANCE
BAY
100111
TRAILER
MAINTENANCE
BAY
H A
Z M
A T
F
I R
E
C
A B
I N
E T
S
PROVIDE PAINT STRIPE
PARKING FOR CTKS
NCOIC/ASST
NCOIC
MUNITION
STOCKPILE
NCOIC
PRODUCTION
NCOIC
TK
OFFICE
OFFICE
MECH.
RM.
C O
R R
I D
O R
BREAK ROOM
OPERATIONS
CONTROL
TSGT
SPACE
STORAGE
DRAWN BY-
DATE-PROJECT NAME
REVISIONS
DESCRIPTION DATENO.
CHECKED BY:
APPROVED BY:
PROGRAM MANAGER:
PROJECT NUMBER
DESCRIPTION
FEDERAL
NetCentric Technology, LLC
DRAWING NO.
SUPPLEMENTARY
SCALE: 1/16"-1'-0"
BUILDING 737
N
Bldg 737 Floor Plan
Renovate B737 & B733 6/14/2023
K Hill MHMV-210015
J Manzanares
AE-1
KEYED NOTES
1. REMOVE WALL, DOOR & FRAME,
COMPLETE (APPROX. 17'-0")
2. STC 50 RATED WOOD DOOR ASSEMBLY
WITH 20 MIN. FIRE-RATING. PROVIDE
SECURITY HARDWARE. MATCH EXISTING
DOORS.
3. CONVERT EXISTING WALL TO STC 50
SOUND ASSEMBLY WALLS. EXTEND
WALLS TO DECK. MAINTAIN CORRIDOR
WALL AS A 1 HR FIRE-RATED ASSEMBLY.
4. NEW 1 HR FIRE-RATED OVERHEAD
COILING COUNTER DOOR.
5. NEW STANDARD HM DOOR AND FRAME.
6. NEW WALL, GYP BOARD, METAL STUD
TO DECK.
7. NEW WALL, STC 50, WITH 2 LAYERS
GYP BOARD EACH SIDE, METAL STUD
TO DECK.
8. NEW WALL, GYP BOARD, METAL STUD TO
10'-0" AFF.
9. NEW CEILING, LIGHT GAGE FRAME WITH
2 LAYERS OF GYP BOARD ON EACH SIDE.
10. CEILING SLOPES FROM 10'-0" AFF TO
ABOVE WINDOWS AT 13'-0" AFF.
11. EXPOSED STRUCTURE.
12. MAINTAIN CORRIDOR WALL AS A 1HR
FIRE-RATED ASSEMBLY, WHILE ADDING
ANOTHER LAYER OF 5/8" GWB. STC50
13. NEW WALL TOP BRACED @ 45° ANGLE AT
48" O.C. & EXTEND 6" ABOVE SLOPE
CEILING PLANE.
LEGEND
EXISTING WALL
NEW WALL TO DECK
TO BE REMOVED
NEW WALL TO CEILING
UP DATED KEYED NOTES 4/29/2024
AutoCAD SHX Text
2050 WYOMING BLVD SE, BLDG. 20686 KIRTLAND AIR FORCE BASE, NM 87117-5005
| Sheets and Views |
| AE-1 |
File details come from the government source that posted it. Updated .