Question about the shielded wire,

1. How many shielded wire for 46 channels?

Answer: Each of the 46 channels should have a #20 AWG (min.) shielded wire per MIL‐W‐16878

2. What's the expected working life?

Answer: Assume 10 – 15 year working life with periodic maintenance based on the duty cycle